[2026-08-08 20:28:56.809 UTC] [V] 485ChCtl <C2> pv-pcs send request.
[2026-08-08 20:28:56.810 UTC] [D] VarInf update ofs_rate:0.000000
[2026-08-08 20:28:56.810 UTC] [V] VarInf LimitSet rt[2] val[170] key[ValueOn]
[2026-08-08 20:28:56.810 UTC] [D] VarInf output_mode:8
[2026-08-08 20:28:56.810 UTC] [D] VarInf update ofs_rate:0.000000
[2026-08-08 20:28:56.810 UTC] [D] VarInf Limit setRate[0.000000] rate[0.000000] value100[1000.000000] value0[0.000000]
[2026-08-08 20:28:56.810 UTC] [V] 485DevCtl <C2:01> ChangeOutputRateToDevice rate:0.000000 set_rate1
[2026-08-08 20:28:56.810 UTC] [D] VarInf Limit rt[2] int_set_rate[1] server_rate[0.000000] rated_output[100.000000] solar_battery_power[100.000000]
[2026-08-08 20:28:56.812 UTC] [D] 485AcReq <C2:01> PutOStreamForBc [3][0d000010138e00020400aa0001466f]
[2026-08-08 20:28:56.828 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:28:56.828 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:28:56.860 UTC] [V] 485DevCtl <C1:06> AnalyzeResponseData proc restart cnt:360449 UPRstat:0
[2026-08-08 20:28:56.860 UTC] [V] Res no response condition. set normal condition.
[2026-08-08 20:28:56.861 UTC] [D] 485DevCtl <C1:06> RcvDat status[2] len[21] [06031000000000022ee435000000000291d3f295f0]
[2026-08-08 20:28:56.861 UTC] [D] 485DevCtl <C1:06> ResCnd OperationId [2] IsNormal[1] 
[2026-08-08 20:28:56.864 UTC] [V] StructInfo Add 36627.509000 = 0.000000+36627.509000+0.000000
[2026-08-08 20:28:56.864 UTC] [V] 485DevCtl <C1:06> [01][603238][3662750.900000][2][kWh]
[2026-08-08 20:28:56.864 UTC] [V] SummDat SetVrmValue dev_id:6 val:3662750.900000 sc:2
[2026-08-08 20:28:56.865 UTC] [V] OCMgr SetMeterValue PhId:0106, branchNo:01, valueId:603238, value:3662750.900000, scaleFactor:2, devId:6
[2026-08-08 20:28:56.876 UTC] [V] StructInfo Add 43111.410000 = 0.000000+43111.410000+0.000000
[2026-08-08 20:28:56.876 UTC] [V] 485DevCtl <C1:06> [01][613239][4311141.000000][2][kWh]
[2026-08-08 20:28:56.876 UTC] [V] SummDat SetVrmValue dev_id:6 val:4311141.000000 sc:2
[2026-08-08 20:28:56.877 UTC] [V] OCMgr SetMeterValue PhId:0106, branchNo:01, valueId:613239, value:4311141.000000, scaleFactor:2, devId:6
[2026-08-08 20:28:56.888 UTC] [V] 485DevCtl <C1:06> device_type:Batt-Meter
[2026-08-08 20:28:56.895 UTC] [V] 485ChCtl <C1> set rt:0
[2026-08-08 20:28:56.898 UTC] [D] 485ChCtl <C1> monitoring dev All Send
[2026-08-08 20:28:56.927 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:28:56.928 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:28:57.028 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:28:57.028 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:28:57.109 UTC] [V] 485ChCtl <C2> set rt:0
[2026-08-08 20:28:57.109 UTC] [V] 485ChCtl <C2> StartDeviceCommunicationForOutputFluctuationSuppressionControlBroadcast 4 cnt:3604617, monitor_cnt:59, bc_elapsed:3604617, min:10, max:40
[2026-08-08 20:28:57.110 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :9
[2026-08-08 20:28:57.111 UTC] [V] 485ChCtl <C2> send request:Sungrow08
[2026-08-08 20:28:57.111 UTC] [D] 485AcReq <C2:02> PutOStream [9][0800020413fa00179482]
[2026-08-08 20:28:57.127 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:28:57.128 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:28:57.228 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:28:57.228 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:28:57.328 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:28:57.328 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:28:57.328 UTC] [V] OFSCtrl Control charge discharge proc start.
[2026-08-08 20:28:57.328 UTC] [V] OFSCtrl CHG 20 p_th(t):-1109.900000 = p_th_old_:-1100.000000 + lev_cd_:-0.300000 * (total_pcs_capacity_:99000.000000 * cof_spec_:2.000000 / 60 * (time_threshold_renew:10.000000 * 10)), min:-1100.000000, max:119300.000000
[2026-08-08 20:28:57.329 UTC] [V] OFSCtrl CHG 21 batt_w:350.994526 = old:354.432026 +  kp:0.550000 * e:-6.250000 + ki:0.000000 * sume:9163230.700228 + kd:0.040000 * (e:-6.250000 - e1:-6.250000)
[2026-08-08 20:28:57.329 UTC] [V] OFSCtrl CHG 29 q:3.000000, mod(round):1.000000
[2026-08-08 20:28:57.329 UTC] [D] OFSCtrl battery ctrl val:0.700000
[2026-08-08 20:28:57.331 UTC] [V] 485ChCtl <C3> battery limit on [4.000000,] request.
[2026-08-08 20:28:57.331 UTC] [V] OFSCtrl Control charge discharge proc:01->02->BATT_CHK->03->04->05->06->07->10->11->20->21->22->23->24->25->27->28->29->30->31->32->33->34
[2026-08-08 20:28:57.427 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:28:57.427 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:28:57.429 UTC] [V] 485ChCtl <C3> battery send request.1
[2026-08-08 20:28:57.430 UTC] [D] VarInf Limit_Bat rt[2]set val[4] set rate[0.800000] value100[500] value-100[-500]
[2026-08-08 20:28:57.432 UTC] [D] 485AcReq <C3:01> PutOStream [6][0f000001000000090110278e0001020004]
[2026-08-08 20:28:57.485 UTC] [V] Res no response condition. set normal condition.
[2026-08-08 20:28:57.488 UTC] [D] 485DevCtl <C2:02> RcvDat status[2] len[51] [02042e000000000000000000000000ffffffffffffffff03e8ffffffff420e0000ffffffffffffffffffffffffffffffff914e]
[2026-08-08 20:28:57.489 UTC] [D] 485DevCtl <C2:02> ResCnd OperationId [9] IsNormal[1] 
[2026-08-08 20:28:57.489 UTC] [V] 485DevCtl <C2:02> [04][101100][0.000000][1][V]
[2026-08-08 20:28:57.489 UTC] [V] SummDat SetVrmValue dev_id:8 val:0.000000 sc:3
[2026-08-08 20:28:57.490 UTC] [V] OCMgr SetMeterValue PhId:0202, branchNo:04, valueId:101100, value:0.000000, scaleFactor:1, devId:8
[2026-08-08 20:28:57.490 UTC] [V] 485DevCtl <C2:02> [04][101101][0.000000][1][A]
[2026-08-08 20:28:57.490 UTC] [V] SummDat SetVrmValue dev_id:8 val:0.000000 sc:3
[2026-08-08 20:28:57.490 UTC] [V] OCMgr SetMeterValue PhId:0202, branchNo:04, valueId:101101, value:0.000000, scaleFactor:1, devId:8
[2026-08-08 20:28:57.491 UTC] [V] 485DevCtl <C2:02> [05][101100][0.000000][1][V]
[2026-08-08 20:28:57.491 UTC] [V] SummDat SetVrmValue dev_id:8 val:0.000000 sc:3
[2026-08-08 20:28:57.491 UTC] [V] OCMgr SetMeterValue PhId:0202, branchNo:05, valueId:101100, value:0.000000, scaleFactor:1, devId:8
[2026-08-08 20:28:57.491 UTC] [V] 485DevCtl <C2:02> [05][101101][0.000000][1][A]
[2026-08-08 20:28:57.491 UTC] [V] SummDat SetVrmValue dev_id:8 val:0.000000 sc:3
[2026-08-08 20:28:57.491 UTC] [V] OCMgr SetMeterValue PhId:0202, branchNo:05, valueId:101101, value:0.000000, scaleFactor:1, devId:8
[2026-08-08 20:28:57.507 UTC] [V] 485DevCtl <C2:02> [06][101100][0.000000][1][V]
[2026-08-08 20:28:57.511 UTC] [V] SummDat SetVrmValue dev_id:8 val:0.000000 sc:3
[2026-08-08 20:28:57.513 UTC] [V] OCMgr SetMeterValue PhId:0202, branchNo:06, valueId:101100, value:0.000000, scaleFactor:1, devId:8
[2026-08-08 20:28:57.514 UTC] [V] 485DevCtl <C2:02> [06][101101][0.000000][1][A]
[2026-08-08 20:28:57.514 UTC] [V] SummDat SetVrmValue dev_id:8 val:0.000000 sc:3
[2026-08-08 20:28:57.514 UTC] [V] OCMgr SetMeterValue PhId:0202, branchNo:06, valueId:101101, value:0.000000, scaleFactor:1, devId:8
[2026-08-08 20:28:57.515 UTC] [V] 485DevCtl <C2:02> device_type:PV-PCS
[2026-08-08 20:28:57.528 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:28:57.528 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:28:57.538 UTC] [V] 485ChCtl <C2> set rt:0
[2026-08-08 20:28:57.538 UTC] [D] 485ChCtl <C2> monitoring dev All Send
[2026-08-08 20:28:57.588 UTC] [V] 485DevCtl <C3:01> AnalyzeResponseData proc restart cnt:360457 UPRstat:0
[2026-08-08 20:28:57.589 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-08 20:28:57.590 UTC] [D] 485DevCtl <C3:01> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-08 20:28:57.590 UTC] [D] 485DevCtl <C3:01> ResCnd OperationId [6] IsNormal[1] 
[2026-08-08 20:28:57.590 UTC] [V] 485DevCtl <C3:01> device_type:Battery
[2026-08-08 20:28:57.590 UTC] [V] 485ChCtl <C3> set rt:0
[2026-08-08 20:28:57.628 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:28:57.628 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:28:57.679 UTC] [V] OFSCtrl [/var/local/solajithome/function/output_fluctuation_suppression/batt_data] write success.
[2026-08-08 20:28:57.728 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:28:57.728 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:28:57.827 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:28:57.828 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:28:57.927 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:28:57.927 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:28:58.028 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:28:58.028 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:28:58.128 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:28:58.128 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:28:58.227 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:28:58.228 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:28:58.328 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:28:58.328 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:28:58.328 UTC] [V] OFSCtrl Control charge discharge proc start.
[2026-08-08 20:28:58.328 UTC] [V] OFSCtrl CHG 20 p_th(t):-1109.900000 = p_th_old_:-1100.000000 + lev_cd_:-0.300000 * (total_pcs_capacity_:99000.000000 * cof_spec_:2.000000 / 60 * (time_threshold_renew:10.000000 * 10)), min:-1100.000000, max:119300.000000
[2026-08-08 20:28:58.329 UTC] [V] OFSCtrl CHG 21 batt_w:347.557026 = old:350.994526 +  kp:0.550000 * e:-6.250000 + ki:0.000000 * sume:9163224.450228 + kd:0.040000 * (e:-6.250000 - e1:-6.250000)
[2026-08-08 20:28:58.329 UTC] [V] OFSCtrl CHG 29 q:3.000000, mod(round):0.000000
[2026-08-08 20:28:58.329 UTC] [D] OFSCtrl battery ctrl val:0.700000
[2026-08-08 20:28:58.329 UTC] [V] 485ChCtl <C3> battery limit on [3.000000,] request.
[2026-08-08 20:28:58.329 UTC] [V] 485ChCtl <C3> battery send request.1
[2026-08-08 20:28:58.330 UTC] [D] VarInf Limit_Bat rt[2]set val[3] set rate[0.600000] value100[500] value-100[-500]
[2026-08-08 20:28:58.332 UTC] [D] 485AcReq <C3:01> PutOStream [6][0f000001000000090110278e0001020003]
[2026-08-08 20:28:58.336 UTC] [V] OFSCtrl Control charge discharge proc:01->02->BATT_CHK->03->04->05->06->07->10->11->20->21->22->23->24->25->27->28->29->30->31->32->33->34
[2026-08-08 20:28:58.428 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:28:58.428 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:28:58.487 UTC] [V] 485DevCtl <C3:01> AnalyzeResponseData proc restart cnt:360457 UPRstat:0
[2026-08-08 20:28:58.490 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-08 20:28:58.490 UTC] [D] 485DevCtl <C3:01> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-08 20:28:58.490 UTC] [D] 485DevCtl <C3:01> ResCnd OperationId [6] IsNormal[1] 
[2026-08-08 20:28:58.490 UTC] [V] 485DevCtl <C3:01> device_type:Battery
[2026-08-08 20:28:58.491 UTC] [V] 485ChCtl <C3> set rt:0
[2026-08-08 20:28:58.527 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:28:58.528 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:28:58.627 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:28:58.627 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:28:58.679 UTC] [V] OFSCtrl [/var/local/solajithome/function/output_fluctuation_suppression/batt_data] write success.
[2026-08-08 20:28:58.727 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:28:58.727 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:28:58.827 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:28:58.827 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:28:58.928 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:28:58.928 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:28:59.028 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:28:59.028 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:28:59.127 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:28:59.128 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:28:59.227 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:28:59.228 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:28:59.327 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:28:59.327 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:28:59.328 UTC] [V] OFSCtrl Control charge discharge proc start.
[2026-08-08 20:28:59.328 UTC] [V] OFSCtrl CHG 20 p_th(t):-1109.900000 = p_th_old_:-1100.000000 + lev_cd_:-0.300000 * (total_pcs_capacity_:99000.000000 * cof_spec_:2.000000 / 60 * (time_threshold_renew:10.000000 * 10)), min:-1100.000000, max:119300.000000
[2026-08-08 20:28:59.328 UTC] [V] OFSCtrl CHG 21 batt_w:344.119526 = old:347.557026 +  kp:0.550000 * e:-6.250000 + ki:0.000000 * sume:9163218.200228 + kd:0.040000 * (e:-6.250000 - e1:-6.250000)
[2026-08-08 20:28:59.329 UTC] [V] OFSCtrl CHG 29 q:3.000000, mod(round):0.000000
[2026-08-08 20:28:59.329 UTC] [D] OFSCtrl battery ctrl val:0.700000
[2026-08-08 20:28:59.329 UTC] [V] 485ChCtl <C3> battery limit on [3.000000,] request.
[2026-08-08 20:28:59.329 UTC] [V] OFSCtrl Control charge discharge proc:01->02->BATT_CHK->03->04->05->06->07->10->11->20->21->22->23->24->25->27->28->29->30->31->32->33->34
[2026-08-08 20:28:59.330 UTC] [V] 485ChCtl <C3> battery send request.1
[2026-08-08 20:28:59.330 UTC] [D] VarInf Limit_Bat rt[2]set val[3] set rate[0.600000] value100[500] value-100[-500]
[2026-08-08 20:28:59.332 UTC] [D] 485AcReq <C3:01> PutOStream [6][0f000001000000090110278e0001020003]
[2026-08-08 20:28:59.428 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:28:59.428 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:28:59.488 UTC] [V] 485DevCtl <C3:01> AnalyzeResponseData proc restart cnt:360458 UPRstat:0
[2026-08-08 20:28:59.490 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-08 20:28:59.490 UTC] [D] 485DevCtl <C3:01> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-08 20:28:59.490 UTC] [D] 485DevCtl <C3:01> ResCnd OperationId [6] IsNormal[1] 
[2026-08-08 20:28:59.490 UTC] [V] 485DevCtl <C3:01> device_type:Battery
[2026-08-08 20:28:59.491 UTC] [V] 485ChCtl <C3> set rt:0
[2026-08-08 20:28:59.527 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:28:59.528 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:28:59.627 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:28:59.627 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:28:59.679 UTC] [V] OFSCtrl [/var/local/solajithome/function/output_fluctuation_suppression/batt_data] write success.
[2026-08-08 20:28:59.727 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:28:59.727 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:28:59.827 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:28:59.827 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:28:59.928 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:28:59.928 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:00.028 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:00.029 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:00.127 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:00.127 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:00.227 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:00.227 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:00.328 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:00.328 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:00.328 UTC] [V] OFSCtrl Control charge discharge proc start.
[2026-08-08 20:29:00.329 UTC] [V] OFSCtrl CHG 20 p_th(t):-1109.900000 = p_th_old_:-1100.000000 + lev_cd_:-0.300000 * (total_pcs_capacity_:99000.000000 * cof_spec_:2.000000 / 60 * (time_threshold_renew:10.000000 * 10)), min:-1100.000000, max:119300.000000
[2026-08-08 20:29:00.329 UTC] [V] OFSCtrl CHG 21 batt_w:340.682026 = old:344.119526 +  kp:0.550000 * e:-6.250000 + ki:0.000000 * sume:9163211.950228 + kd:0.040000 * (e:-6.250000 - e1:-6.250000)
[2026-08-08 20:29:00.330 UTC] [V] OFSCtrl CHG 29 q:3.000000, mod(round):0.000000
[2026-08-08 20:29:00.330 UTC] [D] OFSCtrl battery ctrl val:0.700000
[2026-08-08 20:29:00.331 UTC] [V] 485ChCtl <C3> battery limit on [3.000000,] request.
[2026-08-08 20:29:00.331 UTC] [V] OFSCtrl Control charge discharge proc:01->02->BATT_CHK->03->04->05->06->07->10->11->20->21->22->23->24->25->27->28->29->30->31->32->33->34
[2026-08-08 20:29:00.393 UTC] [V] 485DevCtl <C1:01> device_type:Irr-Meter
[2026-08-08 20:29:00.393 UTC] [V] 485DevCtl <C1:01> device_type:Irr-Meter
[2026-08-08 20:29:00.394 UTC] [V] 485ChCtl <C1> fixed cycle Irr-Meter
[2026-08-08 20:29:00.394 UTC] [V] 485DevCtl <C1:01> Dev not PCS IsNeedToChangeOControlState
[2026-08-08 20:29:00.394 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :1
[2026-08-08 20:29:00.396 UTC] [V] 485ChCtl <C1> send request:Irr01
[2026-08-08 20:29:00.397 UTC] [D] 485AcReq <C1:01> PutOStream [1][080001040000000271cb]
[2026-08-08 20:29:00.427 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:00.428 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:00.430 UTC] [V] 485ChCtl <C3> battery send request.1
[2026-08-08 20:29:00.430 UTC] [D] VarInf Limit_Bat rt[2]set val[3] set rate[0.600000] value100[500] value-100[-500]
[2026-08-08 20:29:00.432 UTC] [D] 485AcReq <C3:01> PutOStream [6][0f000001000000090110278e0001020003]
[2026-08-08 20:29:00.528 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:00.528 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:00.588 UTC] [V] 485DevCtl <C3:01> AnalyzeResponseData proc restart cnt:360460 UPRstat:0
[2026-08-08 20:29:00.589 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-08 20:29:00.589 UTC] [D] 485DevCtl <C3:01> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-08 20:29:00.590 UTC] [D] 485DevCtl <C3:01> ResCnd OperationId [6] IsNormal[1] 
[2026-08-08 20:29:00.590 UTC] [V] 485DevCtl <C3:01> device_type:Battery
[2026-08-08 20:29:00.590 UTC] [V] 485ChCtl <C3> set rt:0
[2026-08-08 20:29:00.627 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:00.628 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:00.679 UTC] [V] OFSCtrl [/var/local/solajithome/function/output_fluctuation_suppression/batt_data] write success.
[2026-08-08 20:29:00.723 UTC] [V] 485DevCtl <C1:01> AnalyzeResponseData proc restart cnt:360461 UPRstat:0
[2026-08-08 20:29:00.723 UTC] [V] Res no response condition. set normal condition.
[2026-08-08 20:29:00.724 UTC] [D] 485DevCtl <C1:01> RcvDat status[2] len[9] [010404000002013b24]
[2026-08-08 20:29:00.724 UTC] [D] 485DevCtl <C1:01> ResCnd OperationId [1] IsNormal[1] 
[2026-08-08 20:29:00.724 UTC] [V] OFSCtrl Rcv set flux_of_solar:0.000000
[2026-08-08 20:29:00.724 UTC] [V] 485DevCtl <C1:01> [01][401006][0.000000][1][W/m2]
[2026-08-08 20:29:00.725 UTC] [V] SummDat SetVrmValue dev_id:1 val:0.000000 sc:3
[2026-08-08 20:29:00.726 UTC] [V] OCMgr SetMeterValue PhId:0101, branchNo:01, valueId:401006, value:0.000000, scaleFactor:1, devId:1
[2026-08-08 20:29:00.726 UTC] [V] 485DevCtl <C1:01> [01][421005][263.000000][1][℃]
[2026-08-08 20:29:00.726 UTC] [V] SummDat SetVrmValue dev_id:1 val:26300.000000 sc:3
[2026-08-08 20:29:00.727 UTC] [V] OCMgr SetMeterValue PhId:0101, branchNo:01, valueId:421005, value:263.000000, scaleFactor:1, devId:1
[2026-08-08 20:29:00.727 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:00.727 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:00.729 UTC] [V] 485ChCtl <C3> StartDeviceCommunicationForOutputFluctuationSuppressionControlBroadcast 4 cnt:3604653, monitor_cnt:50, bc_elapsed:3604653, min:10, max:40
[2026-08-08 20:29:00.729 UTC] [V] OFSCtrl /var/local/solajithome/function/output_fluctuation_suppression/state is exist:0
[2026-08-08 20:29:00.730 UTC] [V] 485DevCtl <C3:01> Dev not PCS IsNeedToChangeOControlState
[2026-08-08 20:29:00.733 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :3
[2026-08-08 20:29:00.734 UTC] [V] 485ChCtl <C3> send request:Sungrow11
[2026-08-08 20:29:00.734 UTC] [D] 485AcReq <C3:01> PutOStream [3][0c00000100000006010435260018]
[2026-08-08 20:29:00.738 UTC] [V] 485DevCtl <C1:01> device_type:Irr-Meter
[2026-08-08 20:29:00.739 UTC] [V] OFSCtrl Irr-Meter received.
[2026-08-08 20:29:00.745 UTC] [V] 485ChCtl <C1> set rt:0
[2026-08-08 20:29:00.747 UTC] [V] 485DevCtl <C1:01> device_type:Irr-Meter
[2026-08-08 20:29:00.793 UTC] [V] 485DevCtl <C1:04> device_type:CO-Meter
[2026-08-08 20:29:00.793 UTC] [V] 485DevCtl <C1:04> device_type:CO-Meter
[2026-08-08 20:29:00.793 UTC] [V] 485ChCtl <C1> fixed cycle CO-Meter
[2026-08-08 20:29:00.793 UTC] [V] 485DevCtl <C1:04> Dev not PCS IsNeedToChangeOControlState
[2026-08-08 20:29:00.793 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :1
[2026-08-08 20:29:00.794 UTC] [V] 485ChCtl <C1> send request:omron05
[2026-08-08 20:29:00.796 UTC] [D] 485AcReq <C1:04> PutOStream [1][0800040300030014b590]
[2026-08-08 20:29:00.827 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:00.827 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:00.867 UTC] [V] 485DevCtl <C3:01> AnalyzeResponseData proc restart cnt:360460 UPRstat:0
[2026-08-08 20:29:00.869 UTC] [D] 485DevCtl <C3:01> RcvDat status[0] len[57] [0001000000330104301e3f0000006e03e81e3f006e00010001ffff0100ffff013b013bffff008c008c00640064ffff7e367b70012c011d02bb]
[2026-08-08 20:29:00.869 UTC] [D] 485DevCtl <C3:01> ResCnd OperationId [3] IsNormal[1]  ConditionType [lggrdev:Normal] Action[-1]
[2026-08-08 20:29:00.870 UTC] [V] 485DevCtl <C3:01> [01][721100][7743.000000][1][V]
[2026-08-08 20:29:00.870 UTC] [V] SummDat SetVrmValue dev_id:9 val:774300.000000 sc:3
[2026-08-08 20:29:00.870 UTC] [V] OCMgr SetMeterValue PhId:0301, branchNo:01, valueId:721100, value:7743.000000, scaleFactor:1, devId:9
[2026-08-08 20:29:00.870 UTC] [V] 485DevCtl <C3:01> [01][721101][0.000000][1][A]
[2026-08-08 20:29:00.871 UTC] [V] SummDat SetVrmValue dev_id:9 val:0.000000 sc:3
[2026-08-08 20:29:00.871 UTC] [V] OCMgr SetMeterValue PhId:0301, branchNo:01, valueId:721101, value:0.000000, scaleFactor:1, devId:9
[2026-08-08 20:29:00.871 UTC] [V] OFSCtrl change set SOC(t):11.000000 drive cnt:1
[2026-08-08 20:29:00.871 UTC] [V] OFSCtrl Rcv set soc[0301]:11.000000
[2026-08-08 20:29:00.871 UTC] [V] 485DevCtl <C3:01> [01][721035][110.000000][1][%]
[2026-08-08 20:29:00.871 UTC] [V] SummDat SetVrmValue dev_id:9 val:11000.000000 sc:3
[2026-08-08 20:29:00.872 UTC] [V] OCMgr SetMeterValue PhId:0301, branchNo:01, valueId:721035, value:110.000000, scaleFactor:1, devId:9
[2026-08-08 20:29:00.872 UTC] [V] 485DevCtl <C3:01> [01][721036][1000.000000][1][%]
[2026-08-08 20:29:00.872 UTC] [V] SummDat SetVrmValue dev_id:9 val:100000.000000 sc:3
[2026-08-08 20:29:00.882 UTC] [V] OCMgr SetMeterValue PhId:0301, branchNo:01, valueId:721036, value:1000.000000, scaleFactor:1, devId:9
[2026-08-08 20:29:00.888 UTC] [V] 485DevCtl <C3:01> [01][721030][32310.000000][4][V]
[2026-08-08 20:29:00.891 UTC] [V] SummDat SetVrmValue dev_id:9 val:3231.000000 sc:3
[2026-08-08 20:29:00.900 UTC] [V] OCMgr SetMeterValue PhId:0301, branchNo:01, valueId:721030, value:32310.000000, scaleFactor:4, devId:9
[2026-08-08 20:29:00.904 UTC] [V] 485DevCtl <C3:01> [01][721031][31600.000000][4][V]
[2026-08-08 20:29:00.904 UTC] [V] SummDat SetVrmValue dev_id:9 val:3160.000000 sc:3
[2026-08-08 20:29:00.905 UTC] [V] OCMgr SetMeterValue PhId:0301, branchNo:01, valueId:721031, value:31600.000000, scaleFactor:4, devId:9
[2026-08-08 20:29:00.905 UTC] [V] 485DevCtl <C3:01> [01][721032][300.000000][1][℃]
[2026-08-08 20:29:00.905 UTC] [V] SummDat SetVrmValue dev_id:9 val:30000.000000 sc:3
[2026-08-08 20:29:00.916 UTC] [V] OCMgr SetMeterValue PhId:0301, branchNo:01, valueId:721032, value:300.000000, scaleFactor:1, devId:9
[2026-08-08 20:29:00.928 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:00.928 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:00.929 UTC] [V] 485DevCtl <C3:01> [01][721033][285.000000][1][℃]
[2026-08-08 20:29:00.930 UTC] [V] SummDat SetVrmValue dev_id:9 val:28500.000000 sc:3
[2026-08-08 20:29:00.933 UTC] [V] OCMgr SetMeterValue PhId:0301, branchNo:01, valueId:721033, value:285.000000, scaleFactor:1, devId:9
[2026-08-08 20:29:00.935 UTC] [V] 485DevCtl <C3:01> device_type:Battery
[2026-08-08 20:29:00.949 UTC] [V] 485ChCtl <C3> set rt:0
[2026-08-08 20:29:00.949 UTC] [D] 485ChCtl <C3> monitoring dev All Send
[2026-08-08 20:29:01.028 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:01.028 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:01.127 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:01.127 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:01.197 UTC] [V] 485DevCtl <C1:04> AnalyzeResponseData proc restart cnt:360460 UPRstat:0
[2026-08-08 20:29:01.198 UTC] [V] Res no response condition. set normal condition.
[2026-08-08 20:29:01.199 UTC] [D] 485DevCtl <C1:04> RcvDat status[2] len[45] [04032800002205000017e5000017e7ffffffe400000258ffffe87bffffffc4ffffaf7dffffff3200121a81bd15]
[2026-08-08 20:29:01.199 UTC] [D] 485DevCtl <C1:04> ResCnd OperationId [1] IsNormal[1] 
[2026-08-08 20:29:01.199 UTC] [V] OFSCtrl Rcv set p_co:-600.000000, p_co_old:-590.000000
[2026-08-08 20:29:01.200 UTC] [V] 485DevCtl <C1:04> [01][601260][-60.000000][2][kW]
[2026-08-08 20:29:01.201 UTC] [V] SummDat SetVrmValue dev_id:4 val:-600.000000 sc:3
[2026-08-08 20:29:01.206 UTC] [V] OCMgr SetMeterValue PhId:0104, branchNo:01, valueId:601260, value:-60.000000, scaleFactor:2, devId:4
[2026-08-08 20:29:01.216 UTC] [V] 485DevCtl <C1:04> [01][603260][1186433.000000][1][kWh]
[2026-08-08 20:29:01.220 UTC] [V] SummDat SetVrmValue dev_id:4 val:1186433.000000 sc:1
[2026-08-08 20:29:01.221 UTC] [V] OCMgr SetMeterValue PhId:0104, branchNo:01, valueId:603260, value:1186433.000000, scaleFactor:1, devId:4
[2026-08-08 20:29:01.228 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:01.228 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:01.228 UTC] [V] 485DevCtl <C1:04> device_type:CO-Meter
[2026-08-08 20:29:01.230 UTC] [V] OFSCtrl km50 received.
[2026-08-08 20:29:01.231 UTC] [V] OFSCtrl omron05_local_date :2026/08/09 ? 2026/08/09
[2026-08-08 20:29:01.231 UTC] [V] OFSCtrl omron05_local_time :2026/08/09 05 ? 2026/08/09 05
[2026-08-08 20:29:01.232 UTC] [V] OFSCtrl out of control time.
[2026-08-08 20:29:01.232 UTC] [V] OFSCtrl Control pv-pcs proc start.
[2026-08-08 20:29:01.232 UTC] [V] OFSCtrl NOD_month:-1664.000000 = (NOD_month:306 - ((nod_max_/30):23.333333 * (cnt-1):25) * (30/cnt):6.000000 
[2026-08-08 20:29:01.232 UTC] [V] OFSCtrl PCS ratio_month:232.646617 = -k_inhibition_ratio_month:-0.097744 * NOD_month:-1664.000000 + inhibition_ratio_max:70
[2026-08-08 20:29:01.233 UTC] [V] OFSCtrl PCS 05 inhibition_ratio:70.000000 = max(ratio_min:5, min(ratio:70, ratio_hour:70.000000, ratio_day:70.000000, ratio_month:232.646617))
[2026-08-08 20:29:01.233 UTC] [D] OFSCtrl pv-pcs ctrl val:0.000000 old:0.000000
[2026-08-08 20:29:01.233 UTC] [V] OCHisDB set rate:0 t_rate:0 cnt:47
[2026-08-08 20:29:01.247 UTC] [V] 485ChCtl <C2> pv-pcs limit on [0.000000] request.
[2026-08-08 20:29:01.247 UTC] [V] OFSCtrl Control pv-pcs proc:BATT_CHK->01->02->03->04->05->06->07->09->09->10->11->12
[2026-08-08 20:29:01.247 UTC] [V] OFSCtrl Nod calc proc start.
[2026-08-08 20:29:01.248 UTC] [V] OFSCtrl ProcNodCountCalculation culc nod skip stop:0, pause:0, ctl_time:0
[2026-08-08 20:29:01.248 UTC] [V] OFSCtrl update p_co_old:-600.000000
[2026-08-08 20:29:01.248 UTC] [V] OFSCtrl Nod calc proc:
[2026-08-08 20:29:01.248 UTC] [V] 485ChCtl <C1> set rt:0
[2026-08-08 20:29:01.264 UTC] [V] 485DevCtl <C1:04> device_type:CO-Meter
[2026-08-08 20:29:01.310 UTC] [V] 485ChCtl <C2> pv-pcs send request.
[2026-08-08 20:29:01.310 UTC] [D] VarInf update ofs_rate:0.000000
[2026-08-08 20:29:01.310 UTC] [V] VarInf LimitSet rt[2] val[170] key[ValueOn]
[2026-08-08 20:29:01.310 UTC] [D] VarInf output_mode:8
[2026-08-08 20:29:01.310 UTC] [D] VarInf update ofs_rate:0.000000
[2026-08-08 20:29:01.311 UTC] [D] VarInf Limit setRate[0.000000] rate[0.000000] value100[1000.000000] value0[0.000000]
[2026-08-08 20:29:01.311 UTC] [V] 485DevCtl <C2:01> ChangeOutputRateToDevice rate:0.000000 set_rate1
[2026-08-08 20:29:01.311 UTC] [D] VarInf Limit rt[2] int_set_rate[1] server_rate[0.000000] rated_output[100.000000] solar_battery_power[100.000000]
[2026-08-08 20:29:01.313 UTC] [D] 485AcReq <C2:01> PutOStreamForBc [3][0d000010138e00020400aa0001466f]
[2026-08-08 20:29:01.327 UTC] [V] OFSCtrl limit chk 400 < 800 < [1076->1076] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:01.328 UTC] [V] OFSCtrl angif value:1076 power_val_:-1025.000000
[2026-08-08 20:29:01.328 UTC] [V] OFSCtrl Control charge discharge proc start.
[2026-08-08 20:29:01.328 UTC] [V] OFSCtrl CHG 20 p_th(t):-1109.900000 = p_th_old_:-1100.000000 + lev_cd_:-0.300000 * (total_pcs_capacity_:99000.000000 * cof_spec_:2.000000 / 60 * (time_threshold_renew:10.000000 * 10)), min:-1100.000000, max:119300.000000
[2026-08-08 20:29:01.328 UTC] [V] OFSCtrl CHG 21 batt_w:296.682026 = old:340.682026 +  kp:0.550000 * e:-75.000000 + ki:0.000000 * sume:9163136.950228 + kd:0.040000 * (e:-75.000000 - e1:-6.250000)
[2026-08-08 20:29:01.329 UTC] [V] OFSCtrl CHG 29 q:2.000000, mod(round):1.000000
[2026-08-08 20:29:01.329 UTC] [D] OFSCtrl battery ctrl val:0.600000
[2026-08-08 20:29:01.329 UTC] [V] 485ChCtl <C3> battery limit on [3.000000,] request.
[2026-08-08 20:29:01.329 UTC] [V] OFSCtrl Control charge discharge proc:01->02->BATT_CHK->03->04->05->06->07->10->11->20->21->22->23->24->25->27->28->29->30->31->32->33->34
[2026-08-08 20:29:01.428 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:01.428 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:01.429 UTC] [V] 485ChCtl <C3> battery send request.1
[2026-08-08 20:29:01.430 UTC] [D] VarInf Limit_Bat rt[2]set val[3] set rate[0.600000] value100[500] value-100[-500]
[2026-08-08 20:29:01.431 UTC] [D] 485AcReq <C3:01> PutOStream [6][0f000001000000090110278e0001020003]
[2026-08-08 20:29:01.528 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:01.528 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:01.588 UTC] [V] 485DevCtl <C3:01> AnalyzeResponseData proc restart cnt:360461 UPRstat:0
[2026-08-08 20:29:01.590 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-08 20:29:01.591 UTC] [D] 485DevCtl <C3:01> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-08 20:29:01.591 UTC] [D] 485DevCtl <C3:01> ResCnd OperationId [6] IsNormal[1] 
[2026-08-08 20:29:01.591 UTC] [V] 485DevCtl <C3:01> device_type:Battery
[2026-08-08 20:29:01.591 UTC] [V] 485ChCtl <C3> set rt:0
[2026-08-08 20:29:01.609 UTC] [V] 485ChCtl <C2> set rt:0
[2026-08-08 20:29:01.627 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:01.628 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:01.679 UTC] [V] OFSCtrl [/var/local/solajithome/function/output_fluctuation_suppression/batt_data] write success.
[2026-08-08 20:29:01.727 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:01.728 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:01.827 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:01.828 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:01.927 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:01.927 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:02.027 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:02.027 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:02.109 UTC] [V] 485ChCtl <C2> StartDeviceCommunicationForOutputFluctuationSuppressionControlBroadcast 4 cnt:3604667, monitor_cnt:50, bc_elapsed:3604667, min:10, max:40
[2026-08-08 20:29:02.109 UTC] [V] OFSCtrl /var/local/solajithome/function/output_fluctuation_suppression/state is exist:0
[2026-08-08 20:29:02.110 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :10
[2026-08-08 20:29:02.110 UTC] [V] 485ChCtl <C2> send request:Sungrow08
[2026-08-08 20:29:02.111 UTC] [D] 485AcReq <C2:01> PutOStream [10][0800010413d80002f574]
[2026-08-08 20:29:02.128 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:02.128 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:02.228 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:02.228 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:02.328 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:02.328 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:02.328 UTC] [V] OFSCtrl Control charge discharge proc start.
[2026-08-08 20:29:02.328 UTC] [V] OFSCtrl CHG 20 p_th(t):-1109.900000 = p_th_old_:-1100.000000 + lev_cd_:-0.300000 * (total_pcs_capacity_:99000.000000 * cof_spec_:2.000000 / 60 * (time_threshold_renew:10.000000 * 10)), min:-1100.000000, max:119300.000000
[2026-08-08 20:29:02.329 UTC] [V] OFSCtrl CHG 21 batt_w:295.994526 = old:296.682026 +  kp:0.550000 * e:-6.250000 + ki:0.000000 * sume:9163130.700228 + kd:0.040000 * (e:-6.250000 - e1:-75.000000)
[2026-08-08 20:29:02.329 UTC] [V] OFSCtrl CHG 29 q:2.000000, mod(round):1.000000
[2026-08-08 20:29:02.329 UTC] [D] OFSCtrl battery ctrl val:0.600000
[2026-08-08 20:29:02.329 UTC] [V] 485ChCtl <C3> battery limit on [3.000000,] request.
[2026-08-08 20:29:02.329 UTC] [V] OFSCtrl Control charge discharge proc:01->02->BATT_CHK->03->04->05->06->07->10->11->20->21->22->23->24->25->27->28->29->30->31->32->33->34
[2026-08-08 20:29:02.329 UTC] [V] 485ChCtl <C3> battery send request.1
[2026-08-08 20:29:02.330 UTC] [D] VarInf Limit_Bat rt[2]set val[3] set rate[0.600000] value100[500] value-100[-500]
[2026-08-08 20:29:02.331 UTC] [D] 485AcReq <C3:01> PutOStream [6][0f000001000000090110278e0001020003]
[2026-08-08 20:29:02.428 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:02.428 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:02.431 UTC] [V] Res no response condition. set normal condition.
[2026-08-08 20:29:02.431 UTC] [D] 485DevCtl <C2:01> RcvDat status[2] len[9] [01040400100000fa41]
[2026-08-08 20:29:02.431 UTC] [D] 485DevCtl <C2:01> ResCnd OperationId [10] IsNormal[1] 
[2026-08-08 20:29:02.432 UTC] [V] 485DevCtl <C2:01> device_type:PV-PCS
[2026-08-08 20:29:02.433 UTC] [V] 485ChCtl <C2> set rt:0
[2026-08-08 20:29:02.487 UTC] [V] 485DevCtl <C3:01> AnalyzeResponseData proc restart cnt:360461 UPRstat:0
[2026-08-08 20:29:02.489 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-08 20:29:02.489 UTC] [D] 485DevCtl <C3:01> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-08 20:29:02.490 UTC] [D] 485DevCtl <C3:01> ResCnd OperationId [6] IsNormal[1] 
[2026-08-08 20:29:02.490 UTC] [V] 485DevCtl <C3:01> device_type:Battery
[2026-08-08 20:29:02.490 UTC] [V] 485ChCtl <C3> set rt:0
[2026-08-08 20:29:02.509 UTC] [V] 485ChCtl <C2> StartDeviceCommunicationForOutputFluctuationSuppressionControlBroadcast 4 cnt:3604671, monitor_cnt:54, bc_elapsed:3604671, min:10, max:40
[2026-08-08 20:29:02.510 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :1
[2026-08-08 20:29:02.511 UTC] [V] 485ChCtl <C2> send request:Sungrow08
[2026-08-08 20:29:02.511 UTC] [D] 485AcReq <C2:02> PutOStream [1][08000204138a0024d54c]
[2026-08-08 20:29:02.528 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:02.528 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:02.628 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:02.628 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:02.679 UTC] [V] OFSCtrl [/var/local/solajithome/function/output_fluctuation_suppression/batt_data] write success.
[2026-08-08 20:29:02.728 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:02.728 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:02.827 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:02.828 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:02.918 UTC] [V] Res no response condition. set normal condition.
[2026-08-08 20:29:02.920 UTC] [D] 485DevCtl <C2:02> RcvDat status[2] len[77] [0204480000024a0001171f000000000000000000000000000000000000000000000000000000000000000000000000ffffffffffffffffffffffff000000000000000000000000000014008841]
[2026-08-08 20:29:02.920 UTC] [D] 485DevCtl <C2:02> ResCnd OperationId [1] IsNormal[1] 
[2026-08-08 20:29:02.921 UTC] [V] 485DevCtl <C2:02> [01][115202][0.000000][1][kWh]
[2026-08-08 20:29:02.921 UTC] [V] SummDat SetVrmValue dev_id:8 val:0.000000 sc:1
[2026-08-08 20:29:02.921 UTC] [V] OCMgr SetMeterValue PhId:0202, branchNo:01, valueId:115202, value:0.000000, scaleFactor:1, devId:8
[2026-08-08 20:29:02.922 UTC] [V] 485DevCtl <C2:02> [01][113202][66122.000000][0][kWh]
[2026-08-08 20:29:02.922 UTC] [V] SummDat SetVrmValue dev_id:8 val:66122.000000 sc:0
[2026-08-08 20:29:02.922 UTC] [V] OCMgr SetMeterValue PhId:0202, branchNo:01, valueId:113202, value:66122.000000, scaleFactor:0, devId:8
[2026-08-08 20:29:02.922 UTC] [V] 485DevCtl <C2:02> [01][121005][0.000000][1][℃]
[2026-08-08 20:29:02.922 UTC] [V] SummDat SetVrmValue dev_id:8 val:0.000000 sc:3
[2026-08-08 20:29:02.923 UTC] [V] OCMgr SetMeterValue PhId:0202, branchNo:01, valueId:121005, value:0.000000, scaleFactor:1, devId:8
[2026-08-08 20:29:02.923 UTC] [V] 485DevCtl <C2:02> [01][101100][0.000000][1][V]
[2026-08-08 20:29:02.923 UTC] [V] SummDat SetVrmValue dev_id:8 val:0.000000 sc:3
[2026-08-08 20:29:02.927 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:02.927 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:02.923 UTC] [V] OCMgr SetMeterValue PhId:0202, branchNo:01, valueId:101100, value:0.000000, scaleFactor:1, devId:8
[2026-08-08 20:29:02.942 UTC] [V] 485DevCtl <C2:02> [01][101101][0.000000][1][A]
[2026-08-08 20:29:02.944 UTC] [V] SummDat SetVrmValue dev_id:8 val:0.000000 sc:3
[2026-08-08 20:29:02.949 UTC] [V] OCMgr SetMeterValue PhId:0202, branchNo:01, valueId:101101, value:0.000000, scaleFactor:1, devId:8
[2026-08-08 20:29:02.953 UTC] [V] 485DevCtl <C2:02> [02][101100][0.000000][1][V]
[2026-08-08 20:29:02.956 UTC] [V] SummDat SetVrmValue dev_id:8 val:0.000000 sc:3
[2026-08-08 20:29:02.966 UTC] [V] OCMgr SetMeterValue PhId:0202, branchNo:02, valueId:101100, value:0.000000, scaleFactor:1, devId:8
[2026-08-08 20:29:02.966 UTC] [V] 485DevCtl <C2:02> [02][101101][0.000000][1][A]
[2026-08-08 20:29:02.966 UTC] [V] SummDat SetVrmValue dev_id:8 val:0.000000 sc:3
[2026-08-08 20:29:02.967 UTC] [V] OCMgr SetMeterValue PhId:0202, branchNo:02, valueId:101101, value:0.000000, scaleFactor:1, devId:8
[2026-08-08 20:29:02.980 UTC] [V] 485DevCtl <C2:02> [03][101100][0.000000][1][V]
[2026-08-08 20:29:02.982 UTC] [V] SummDat SetVrmValue dev_id:8 val:0.000000 sc:3
[2026-08-08 20:29:02.988 UTC] [V] OCMgr SetMeterValue PhId:0202, branchNo:03, valueId:101100, value:0.000000, scaleFactor:1, devId:8
[2026-08-08 20:29:02.988 UTC] [V] 485DevCtl <C2:02> [03][101101][0.000000][1][A]
[2026-08-08 20:29:02.989 UTC] [V] SummDat SetVrmValue dev_id:8 val:0.000000 sc:3
[2026-08-08 20:29:02.989 UTC] [V] OCMgr SetMeterValue PhId:0202, branchNo:03, valueId:101101, value:0.000000, scaleFactor:1, devId:8
[2026-08-08 20:29:02.989 UTC] [V] 485DevCtl <C2:02> [01][101102][0.000000][0][W]
[2026-08-08 20:29:02.997 UTC] [V] SummDat SetVrmValue dev_id:8 val:0.000000 sc:3
[2026-08-08 20:29:03.003 UTC] [V] OCMgr SetMeterValue PhId:0202, branchNo:01, valueId:101102, value:0.000000, scaleFactor:0, devId:8
[2026-08-08 20:29:03.008 UTC] [V] 485DevCtl <C2:02> [01][111200][0.000000][1][V]
[2026-08-08 20:29:03.013 UTC] [V] SummDat SetVrmValue dev_id:8 val:0.000000 sc:3
[2026-08-08 20:29:03.016 UTC] [V] OCMgr SetMeterValue PhId:0202, branchNo:01, valueId:111200, value:0.000000, scaleFactor:1, devId:8
[2026-08-08 20:29:03.020 UTC] [V] 485DevCtl <C2:02> [02][111200][0.000000][1][V]
[2026-08-08 20:29:03.020 UTC] [V] SummDat SetVrmValue dev_id:8 val:0.000000 sc:3
[2026-08-08 20:29:03.020 UTC] [V] OCMgr SetMeterValue PhId:0202, branchNo:02, valueId:111200, value:0.000000, scaleFactor:1, devId:8
[2026-08-08 20:29:03.020 UTC] [V] 485DevCtl <C2:02> [03][111200][0.000000][1][V]
[2026-08-08 20:29:03.021 UTC] [V] SummDat SetVrmValue dev_id:8 val:0.000000 sc:3
[2026-08-08 20:29:03.021 UTC] [V] OCMgr SetMeterValue PhId:0202, branchNo:03, valueId:111200, value:0.000000, scaleFactor:1, devId:8
[2026-08-08 20:29:03.021 UTC] [V] 485DevCtl <C2:02> [01][111201][0.000000][1][A]
[2026-08-08 20:29:03.021 UTC] [V] SummDat SetVrmValue dev_id:8 val:0.000000 sc:3
[2026-08-08 20:29:03.021 UTC] [V] OCMgr SetMeterValue PhId:0202, branchNo:01, valueId:111201, value:0.000000, scaleFactor:1, devId:8
[2026-08-08 20:29:03.022 UTC] [V] 485DevCtl <C2:02> [02][111201][0.000000][1][A]
[2026-08-08 20:29:03.027 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:03.027 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:03.022 UTC] [V] SummDat SetVrmValue dev_id:8 val:0.000000 sc:3
[2026-08-08 20:29:03.045 UTC] [V] OCMgr SetMeterValue PhId:0202, branchNo:02, valueId:111201, value:0.000000, scaleFactor:1, devId:8
[2026-08-08 20:29:03.045 UTC] [V] 485DevCtl <C2:02> [03][111201][0.000000][1][A]
[2026-08-08 20:29:03.051 UTC] [V] SummDat SetVrmValue dev_id:8 val:0.000000 sc:3
[2026-08-08 20:29:03.056 UTC] [V] OCMgr SetMeterValue PhId:0202, branchNo:03, valueId:111201, value:0.000000, scaleFactor:1, devId:8
[2026-08-08 20:29:03.060 UTC] [V] 485DevCtl <C2:02> [01][111202][0.000000][0][W]
[2026-08-08 20:29:03.061 UTC] [V] SummDat SetVrmValue dev_id:8 val:0.000000 sc:3
[2026-08-08 20:29:03.065 UTC] [V] OCMgr SetMeterValue PhId:0202, branchNo:01, valueId:111202, value:0.000000, scaleFactor:0, devId:8
[2026-08-08 20:29:03.069 UTC] [V] 485DevCtl <C2:02> [01][111203][0.000000][0][var]
[2026-08-08 20:29:03.071 UTC] [V] SummDat SetVrmValue dev_id:8 val:0.000000 sc:3
[2026-08-08 20:29:03.072 UTC] [V] OCMgr SetMeterValue PhId:0202, branchNo:01, valueId:111203, value:0.000000, scaleFactor:0, devId:8
[2026-08-08 20:29:03.073 UTC] [V] 485DevCtl <C2:02> [01][121007][0.000000][3][]
[2026-08-08 20:29:03.073 UTC] [V] SummDat SetVrmValue dev_id:8 val:0.000000 sc:3
[2026-08-08 20:29:03.077 UTC] [V] OCMgr SetMeterValue PhId:0202, branchNo:01, valueId:121007, value:0.000000, scaleFactor:3, devId:8
[2026-08-08 20:29:03.080 UTC] [V] 485DevCtl <C2:02> [01][131006][0.000000][1][Hz]
[2026-08-08 20:29:03.082 UTC] [V] SummDat SetVrmValue dev_id:8 val:0.000000 sc:3
[2026-08-08 20:29:03.085 UTC] [V] OCMgr SetMeterValue PhId:0202, branchNo:01, valueId:131006, value:0.000000, scaleFactor:1, devId:8
[2026-08-08 20:29:03.091 UTC] [V] 485DevCtl <C2:02> [01][114202][66122.000000][0][kWh]
[2026-08-08 20:29:03.092 UTC] [V] SummDat SetVrmValue dev_id:8 val:66122000.000000 sc:3
[2026-08-08 20:29:03.096 UTC] [V] OCMgr SetMeterValue PhId:0202, branchNo:01, valueId:114202, value:66122.000000, scaleFactor:0, devId:8
[2026-08-08 20:29:03.100 UTC] [V] 485DevCtl <C2:02> device_type:PV-PCS
[2026-08-08 20:29:03.106 UTC] [V] 485DevCtl <C2:02> set2 StatusCode[010100] DeviceName[] DeviceNumber[]
[2026-08-08 20:29:03.106 UTC] [V] 485ChCtl <C2> set rt:0
[2026-08-08 20:29:03.108 UTC] [D] 485ChCtl <C2> monitoring dev All Send
[2026-08-08 20:29:03.128 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:03.128 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:03.228 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:03.228 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:03.327 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:03.328 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:03.328 UTC] [V] OFSCtrl Control charge discharge proc start.
[2026-08-08 20:29:03.328 UTC] [V] OFSCtrl CHG 20 p_th(t):-1109.900000 = p_th_old_:-1100.000000 + lev_cd_:-0.300000 * (total_pcs_capacity_:99000.000000 * cof_spec_:2.000000 / 60 * (time_threshold_renew:10.000000 * 10)), min:-1100.000000, max:119300.000000
[2026-08-08 20:29:03.329 UTC] [V] OFSCtrl CHG 21 batt_w:292.557026 = old:295.994526 +  kp:0.550000 * e:-6.250000 + ki:0.000000 * sume:9163124.450228 + kd:0.040000 * (e:-6.250000 - e1:-6.250000)
[2026-08-08 20:29:03.329 UTC] [V] OFSCtrl CHG 29 q:2.000000, mod(round):1.000000
[2026-08-08 20:29:03.329 UTC] [D] OFSCtrl battery ctrl val:0.600000
[2026-08-08 20:29:03.329 UTC] [V] 485ChCtl <C3> battery limit on [3.000000,] request.
[2026-08-08 20:29:03.329 UTC] [V] OFSCtrl Control charge discharge proc:01->02->BATT_CHK->03->04->05->06->07->10->11->20->21->22->23->24->25->27->28->29->30->31->32->33->34
[2026-08-08 20:29:03.330 UTC] [V] 485ChCtl <C3> battery send request.1
[2026-08-08 20:29:03.330 UTC] [D] VarInf Limit_Bat rt[2]set val[3] set rate[0.600000] value100[500] value-100[-500]
[2026-08-08 20:29:03.332 UTC] [D] 485AcReq <C3:01> PutOStream [6][0f000001000000090110278e0001020003]
[2026-08-08 20:29:03.428 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:03.428 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:03.488 UTC] [V] 485DevCtl <C3:01> AnalyzeResponseData proc restart cnt:360462 UPRstat:0
[2026-08-08 20:29:03.490 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-08 20:29:03.490 UTC] [D] 485DevCtl <C3:01> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-08 20:29:03.490 UTC] [D] 485DevCtl <C3:01> ResCnd OperationId [6] IsNormal[1] 
[2026-08-08 20:29:03.490 UTC] [V] 485DevCtl <C3:01> device_type:Battery
[2026-08-08 20:29:03.491 UTC] [V] 485ChCtl <C3> set rt:0
[2026-08-08 20:29:03.528 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:03.528 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:03.627 UTC] [V] OFSCtrl limit chk 400 < 800 < [1076->1076] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:03.628 UTC] [V] OFSCtrl angif value:1076 power_val_:-1025.000000
[2026-08-08 20:29:03.679 UTC] [V] OFSCtrl [/var/local/solajithome/function/output_fluctuation_suppression/batt_data] write success.
[2026-08-08 20:29:03.728 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:03.728 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:03.827 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:03.828 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:03.927 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:03.927 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:04.027 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:04.028 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:04.127 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:04.127 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:04.227 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:04.227 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:04.328 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:04.328 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:04.328 UTC] [V] OFSCtrl Control charge discharge proc start.
[2026-08-08 20:29:04.328 UTC] [V] OFSCtrl CHG 20 p_th(t):-1109.900000 = p_th_old_:-1100.000000 + lev_cd_:-0.300000 * (total_pcs_capacity_:99000.000000 * cof_spec_:2.000000 / 60 * (time_threshold_renew:10.000000 * 10)), min:-1100.000000, max:119300.000000
[2026-08-08 20:29:04.329 UTC] [V] OFSCtrl CHG 21 batt_w:289.119526 = old:292.557026 +  kp:0.550000 * e:-6.250000 + ki:0.000000 * sume:9163118.200228 + kd:0.040000 * (e:-6.250000 - e1:-6.250000)
[2026-08-08 20:29:04.329 UTC] [V] OFSCtrl CHG 29 q:2.000000, mod(round):1.000000
[2026-08-08 20:29:04.329 UTC] [D] OFSCtrl battery ctrl val:0.600000
[2026-08-08 20:29:04.329 UTC] [V] 485ChCtl <C3> battery limit on [3.000000,] request.
[2026-08-08 20:29:04.330 UTC] [V] 485ChCtl <C3> battery send request.1
[2026-08-08 20:29:04.330 UTC] [D] VarInf Limit_Bat rt[2]set val[3] set rate[0.600000] value100[500] value-100[-500]
[2026-08-08 20:29:04.331 UTC] [D] 485AcReq <C3:01> PutOStream [6][0f000001000000090110278e0001020003]
[2026-08-08 20:29:04.335 UTC] [V] OFSCtrl Control charge discharge proc:01->02->BATT_CHK->03->04->05->06->07->10->11->20->21->22->23->24->25->27->28->29->30->31->32->33->34
[2026-08-08 20:29:04.428 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:04.428 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:04.487 UTC] [V] 485DevCtl <C3:01> AnalyzeResponseData proc restart cnt:360463 UPRstat:0
[2026-08-08 20:29:04.492 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-08 20:29:04.493 UTC] [D] 485DevCtl <C3:01> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-08 20:29:04.494 UTC] [D] 485DevCtl <C3:01> ResCnd OperationId [6] IsNormal[1] 
[2026-08-08 20:29:04.495 UTC] [V] 485DevCtl <C3:01> device_type:Battery
[2026-08-08 20:29:04.498 UTC] [V] 485ChCtl <C3> set rt:0
[2026-08-08 20:29:04.527 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:04.528 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:04.627 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:04.627 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:04.679 UTC] [V] OFSCtrl [/var/local/solajithome/function/output_fluctuation_suppression/batt_data] write success.
[2026-08-08 20:29:04.727 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:04.727 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:04.827 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:04.827 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:04.928 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:04.928 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:05.028 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:05.028 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:05.038 UTC] [V] CIStDb UpdateStatusData. [SELECT no, on_time, off_time FROM contact_input_status WHERE no BETWEEN '1' AND '9' ORDER BY no ASC ]
[2026-08-08 20:29:05.128 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:05.128 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:05.227 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:05.228 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:05.328 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:05.328 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:05.328 UTC] [V] OFSCtrl Control charge discharge proc start.
[2026-08-08 20:29:05.329 UTC] [V] OFSCtrl CHG 20 p_th(t):-1109.900000 = p_th_old_:-1100.000000 + lev_cd_:-0.300000 * (total_pcs_capacity_:99000.000000 * cof_spec_:2.000000 / 60 * (time_threshold_renew:10.000000 * 10)), min:-1100.000000, max:119300.000000
[2026-08-08 20:29:05.330 UTC] [V] OFSCtrl CHG 21 batt_w:285.682026 = old:289.119526 +  kp:0.550000 * e:-6.250000 + ki:0.000000 * sume:9163111.950228 + kd:0.040000 * (e:-6.250000 - e1:-6.250000)
[2026-08-08 20:29:05.331 UTC] [V] OFSCtrl CHG 29 q:2.000000, mod(round):1.000000
[2026-08-08 20:29:05.331 UTC] [D] OFSCtrl battery ctrl val:0.600000
[2026-08-08 20:29:05.332 UTC] [V] 485ChCtl <C3> battery limit on [3.000000,] request.
[2026-08-08 20:29:05.332 UTC] [V] OFSCtrl Control charge discharge proc:01->02->BATT_CHK->03->04->05->06->07->10->11->20->21->22->23->24->25->27->28->29->30->31->32->33->34
[2026-08-08 20:29:05.393 UTC] [V] 485DevCtl <C1:01> device_type:Irr-Meter
[2026-08-08 20:29:05.394 UTC] [V] 485DevCtl <C1:01> device_type:Irr-Meter
[2026-08-08 20:29:05.394 UTC] [V] 485ChCtl <C1> fixed cycle Irr-Meter
[2026-08-08 20:29:05.394 UTC] [V] 485DevCtl <C1:01> Dev not PCS IsNeedToChangeOControlState
[2026-08-08 20:29:05.394 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :1
[2026-08-08 20:29:05.395 UTC] [V] 485ChCtl <C1> send request:Irr01
[2026-08-08 20:29:05.396 UTC] [D] 485AcReq <C1:01> PutOStream [1][080001040000000271cb]
[2026-08-08 20:29:05.428 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:05.428 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:05.429 UTC] [V] 485ChCtl <C3> battery send request.1
[2026-08-08 20:29:05.430 UTC] [D] VarInf Limit_Bat rt[2]set val[3] set rate[0.600000] value100[500] value-100[-500]
[2026-08-08 20:29:05.432 UTC] [D] 485AcReq <C3:01> PutOStream [6][0f000001000000090110278e0001020003]
[2026-08-08 20:29:05.528 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:05.528 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:05.577 UTC] [V] 485DevCtl <C3:01> AnalyzeResponseData proc restart cnt:360465 UPRstat:0
[2026-08-08 20:29:05.579 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-08 20:29:05.579 UTC] [D] 485DevCtl <C3:01> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-08 20:29:05.579 UTC] [D] 485DevCtl <C3:01> ResCnd OperationId [6] IsNormal[1] 
[2026-08-08 20:29:05.579 UTC] [V] 485DevCtl <C3:01> device_type:Battery
[2026-08-08 20:29:05.581 UTC] [V] 485ChCtl <C3> set rt:0
[2026-08-08 20:29:05.628 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:05.628 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:05.679 UTC] [V] OFSCtrl [/var/local/solajithome/function/output_fluctuation_suppression/batt_data] write success.
[2026-08-08 20:29:05.728 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:05.728 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:05.728 UTC] [V] 485DevCtl <C1:01> AnalyzeResponseData proc restart cnt:360466 UPRstat:0
[2026-08-08 20:29:05.728 UTC] [V] Res no response condition. set normal condition.
[2026-08-08 20:29:05.729 UTC] [D] 485DevCtl <C1:01> RcvDat status[2] len[9] [010404000002013b24]
[2026-08-08 20:29:05.729 UTC] [D] 485DevCtl <C1:01> ResCnd OperationId [1] IsNormal[1] 
[2026-08-08 20:29:05.729 UTC] [V] OFSCtrl Rcv set flux_of_solar:0.000000
[2026-08-08 20:29:05.729 UTC] [V] 485DevCtl <C1:01> [01][401006][0.000000][1][W/m2]
[2026-08-08 20:29:05.730 UTC] [V] SummDat SetVrmValue dev_id:1 val:0.000000 sc:3
[2026-08-08 20:29:05.730 UTC] [V] 485ChCtl <C3> StartDeviceCommunicationForOutputFluctuationSuppressionControlBroadcast 4 cnt:3604703, monitor_cnt:50, bc_elapsed:3604703, min:10, max:40
[2026-08-08 20:29:05.730 UTC] [V] OFSCtrl /var/local/solajithome/function/output_fluctuation_suppression/state is exist:0
[2026-08-08 20:29:05.730 UTC] [V] 485DevCtl <C3:01> Dev not PCS IsNeedToChangeOControlState
[2026-08-08 20:29:05.730 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :4
[2026-08-08 20:29:05.731 UTC] [V] 485ChCtl <C3> send request:Sungrow11
[2026-08-08 20:29:05.732 UTC] [D] 485AcReq <C3:01> PutOStream [4][0c00000100000006010427f0002f]
[2026-08-08 20:29:05.735 UTC] [V] OCMgr SetMeterValue PhId:0101, branchNo:01, valueId:401006, value:0.000000, scaleFactor:1, devId:1
[2026-08-08 20:29:05.736 UTC] [V] 485DevCtl <C1:01> [01][421005][263.000000][1][℃]
[2026-08-08 20:29:05.736 UTC] [V] SummDat SetVrmValue dev_id:1 val:26300.000000 sc:3
[2026-08-08 20:29:05.736 UTC] [V] OCMgr SetMeterValue PhId:0101, branchNo:01, valueId:421005, value:263.000000, scaleFactor:1, devId:1
[2026-08-08 20:29:05.737 UTC] [V] 485DevCtl <C1:01> device_type:Irr-Meter
[2026-08-08 20:29:05.737 UTC] [V] OFSCtrl Irr-Meter received.
[2026-08-08 20:29:05.752 UTC] [V] 485ChCtl <C1> set rt:0
[2026-08-08 20:29:05.766 UTC] [V] 485DevCtl <C1:01> device_type:Irr-Meter
[2026-08-08 20:29:05.794 UTC] [V] 485DevCtl <C1:04> device_type:CO-Meter
[2026-08-08 20:29:05.794 UTC] [V] 485DevCtl <C1:04> device_type:CO-Meter
[2026-08-08 20:29:05.794 UTC] [V] 485ChCtl <C1> fixed cycle CO-Meter
[2026-08-08 20:29:05.795 UTC] [V] 485DevCtl <C1:04> Dev not PCS IsNeedToChangeOControlState
[2026-08-08 20:29:05.795 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :1
[2026-08-08 20:29:05.796 UTC] [V] 485ChCtl <C1> send request:omron05
[2026-08-08 20:29:05.796 UTC] [D] 485AcReq <C1:04> PutOStream [1][0800040300030014b590]
[2026-08-08 20:29:05.827 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:05.828 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:05.898 UTC] [V] 485DevCtl <C3:01> AnalyzeResponseData proc restart cnt:360465 UPRstat:0
[2026-08-08 20:29:05.901 UTC] [D] 485DevCtl <C3:01> RcvDat status[0] len[103] [00010000006101045e1e16000800030fbd0fb90fdb000b000c000b000300000000000000000000000000000001000000939df7000091710000012c000000670141302a00000001176f03e701d00000014100d9000019eb00002f4b000100030000000000930000]
[2026-08-08 20:29:05.901 UTC] [D] 485DevCtl <C3:01> ResCnd OperationId [4] IsNormal[1]  ConditionType [lggrdev:Normal] Action[-1]
[2026-08-08 20:29:05.902 UTC] [V] 485DevCtl <C3:01> [05][753053][0.000000][0][]
[2026-08-08 20:29:05.902 UTC] [V] SummDat SetVrmValue dev_id:9 val:0.000000 sc:0
[2026-08-08 20:29:05.902 UTC] [V] OCMgr SetMeterValue PhId:0301, branchNo:05, valueId:753053, value:0.000000, scaleFactor:0, devId:9
[2026-08-08 20:29:05.903 UTC] [V] 485DevCtl <C3:01> [06][753053][0.000000][0][]
[2026-08-08 20:29:05.903 UTC] [V] SummDat SetVrmValue dev_id:9 val:0.000000 sc:0
[2026-08-08 20:29:05.903 UTC] [V] OCMgr SetMeterValue PhId:0301, branchNo:06, valueId:753053, value:0.000000, scaleFactor:0, devId:9
[2026-08-08 20:29:05.903 UTC] [V] 485DevCtl <C3:01> [07][753053][0.000000][0][]
[2026-08-08 20:29:05.903 UTC] [V] SummDat SetVrmValue dev_id:9 val:0.000000 sc:0
[2026-08-08 20:29:05.904 UTC] [V] OCMgr SetMeterValue PhId:0301, branchNo:07, valueId:753053, value:0.000000, scaleFactor:0, devId:9
[2026-08-08 20:29:05.904 UTC] [V] 485DevCtl <C3:01> device_type:Battery
[2026-08-08 20:29:05.904 UTC] [V] 485DevCtl <C3:01> set2 StatusCode[020101]
[2026-08-08 20:29:05.928 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:05.928 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:05.933 UTC] [V] OFSCtrl Bat[0301] StCd[020101]->st[1].
[2026-08-08 20:29:05.935 UTC] [V] OFSCtrl set batt status:[0301]:Drive, All:[0301]:Drive, [DRIVE] 
[2026-08-08 20:29:05.936 UTC] [V] OFSCtrl change set SOC(t):11.000000 drive cnt:1
[2026-08-08 20:29:05.945 UTC] [V] 485DevCtl <C3:01> set2 StatusCode[020101] DeviceName[蓄電池1] DeviceNumber[1]
[2026-08-08 20:29:05.945 UTC] [V] 485ChCtl <C3> set rt:0
[2026-08-08 20:29:05.946 UTC] [D] 485ChCtl <C3> monitoring dev All Send
[2026-08-08 20:29:06.027 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:06.028 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:06.127 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:06.127 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:06.196 UTC] [V] 485DevCtl <C1:04> AnalyzeResponseData proc restart cnt:360465 UPRstat:0
[2026-08-08 20:29:06.197 UTC] [V] Res no response condition. set normal condition.
[2026-08-08 20:29:06.199 UTC] [D] 485DevCtl <C1:04> RcvDat status[2] len[45] [0403280000220b000017e7000017e8ffffffe500000256ffffe8a4ffffffc5ffffaf7dffffff3200121a8157e2]
[2026-08-08 20:29:06.199 UTC] [D] 485DevCtl <C1:04> ResCnd OperationId [1] IsNormal[1] 
[2026-08-08 20:29:06.200 UTC] [V] OFSCtrl Rcv set p_co:-590.000000, p_co_old:-600.000000
[2026-08-08 20:29:06.200 UTC] [V] 485DevCtl <C1:04> [01][601260][-59.000000][2][kW]
[2026-08-08 20:29:06.200 UTC] [V] SummDat SetVrmValue dev_id:4 val:-590.000000 sc:3
[2026-08-08 20:29:06.200 UTC] [V] OCMgr SetMeterValue PhId:0104, branchNo:01, valueId:601260, value:-59.000000, scaleFactor:2, devId:4
[2026-08-08 20:29:06.201 UTC] [V] 485DevCtl <C1:04> [01][603260][1186433.000000][1][kWh]
[2026-08-08 20:29:06.201 UTC] [V] SummDat SetVrmValue dev_id:4 val:1186433.000000 sc:1
[2026-08-08 20:29:06.201 UTC] [V] OCMgr SetMeterValue PhId:0104, branchNo:01, valueId:603260, value:1186433.000000, scaleFactor:1, devId:4
[2026-08-08 20:29:06.201 UTC] [V] 485DevCtl <C1:04> device_type:CO-Meter
[2026-08-08 20:29:06.201 UTC] [V] OFSCtrl km50 received.
[2026-08-08 20:29:06.201 UTC] [V] OFSCtrl omron05_local_date :2026/08/09 ? 2026/08/09
[2026-08-08 20:29:06.202 UTC] [V] OFSCtrl omron05_local_time :2026/08/09 05 ? 2026/08/09 05
[2026-08-08 20:29:06.202 UTC] [V] OFSCtrl out of control time.
[2026-08-08 20:29:06.202 UTC] [V] OFSCtrl Control pv-pcs proc start.
[2026-08-08 20:29:06.202 UTC] [V] OFSCtrl NOD_month:-1664.000000 = (NOD_month:306 - ((nod_max_/30):23.333333 * (cnt-1):25) * (30/cnt):6.000000 
[2026-08-08 20:29:06.202 UTC] [V] OFSCtrl PCS ratio_month:232.646617 = -k_inhibition_ratio_month:-0.097744 * NOD_month:-1664.000000 + inhibition_ratio_max:70
[2026-08-08 20:29:06.203 UTC] [V] OFSCtrl PCS 05 inhibition_ratio:70.000000 = max(ratio_min:5, min(ratio:70, ratio_hour:70.000000, ratio_day:70.000000, ratio_month:232.646617))
[2026-08-08 20:29:06.224 UTC] [D] OFSCtrl pv-pcs ctrl val:0.000000 old:0.000000
[2026-08-08 20:29:06.224 UTC] [V] OCHisDB set rate:0 t_rate:0 cnt:48
[2026-08-08 20:29:06.224 UTC] [V] 485ChCtl <C2> pv-pcs limit on [0.000000] request.
[2026-08-08 20:29:06.224 UTC] [V] OFSCtrl Control pv-pcs proc:BATT_CHK->01->02->03->04->05->06->07->09->09->10->11->12
[2026-08-08 20:29:06.225 UTC] [V] 485ChCtl <C1> set rt:0
[2026-08-08 20:29:06.227 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:06.227 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:06.231 UTC] [V] 485DevCtl <C1:04> device_type:CO-Meter
[2026-08-08 20:29:06.310 UTC] [V] 485ChCtl <C2> pv-pcs send request.
[2026-08-08 20:29:06.310 UTC] [D] VarInf update ofs_rate:0.000000
[2026-08-08 20:29:06.310 UTC] [V] VarInf LimitSet rt[2] val[170] key[ValueOn]
[2026-08-08 20:29:06.310 UTC] [D] VarInf output_mode:8
[2026-08-08 20:29:06.310 UTC] [D] VarInf update ofs_rate:0.000000
[2026-08-08 20:29:06.311 UTC] [D] VarInf Limit setRate[0.000000] rate[0.000000] value100[1000.000000] value0[0.000000]
[2026-08-08 20:29:06.311 UTC] [V] 485DevCtl <C2:01> ChangeOutputRateToDevice rate:0.000000 set_rate1
[2026-08-08 20:29:06.311 UTC] [D] VarInf Limit rt[2] int_set_rate[1] server_rate[0.000000] rated_output[100.000000] solar_battery_power[100.000000]
[2026-08-08 20:29:06.312 UTC] [D] 485AcReq <C2:01> PutOStreamForBc [3][0d000010138e00020400aa0001466f]
[2026-08-08 20:29:06.328 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:06.328 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:06.328 UTC] [V] OFSCtrl Control charge discharge proc start.
[2026-08-08 20:29:06.328 UTC] [V] OFSCtrl CHG 20 p_th(t):-1109.900000 = p_th_old_:-1100.000000 + lev_cd_:-0.300000 * (total_pcs_capacity_:99000.000000 * cof_spec_:2.000000 / 60 * (time_threshold_renew:10.000000 * 10)), min:-1100.000000, max:119300.000000
[2026-08-08 20:29:06.329 UTC] [V] OFSCtrl CHG 21 batt_w:282.244526 = old:285.682026 +  kp:0.550000 * e:-6.250000 + ki:0.000000 * sume:9163105.700228 + kd:0.040000 * (e:-6.250000 - e1:-6.250000)
[2026-08-08 20:29:06.329 UTC] [V] OFSCtrl CHG 29 q:2.000000, mod(round):1.000000
[2026-08-08 20:29:06.329 UTC] [D] OFSCtrl battery ctrl val:0.600000
[2026-08-08 20:29:06.330 UTC] [V] 485ChCtl <C3> battery limit on [3.000000,] request.
[2026-08-08 20:29:06.331 UTC] [V] OFSCtrl Control charge discharge proc:01->02->BATT_CHK->03->04->05->06->07->10->11->20->21->22->23->24->25->27->28->29->30->31->32->33->34
[2026-08-08 20:29:06.427 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:06.427 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:06.430 UTC] [V] 485ChCtl <C3> battery send request.1
[2026-08-08 20:29:06.430 UTC] [D] VarInf Limit_Bat rt[2]set val[3] set rate[0.600000] value100[500] value-100[-500]
[2026-08-08 20:29:06.432 UTC] [D] 485AcReq <C3:01> PutOStream [6][0f000001000000090110278e0001020003]
[2026-08-08 20:29:06.493 UTC] [V] 485ChCtl <C1> StartDeviceCommunicationForOutputFluctuationSuppressionControlBroadcast 4 cnt:3604711, monitor_cnt:100, bc_elapsed:11, min:10, max:40
[2026-08-08 20:29:06.494 UTC] [V] OFSCtrl /var/local/solajithome/function/output_fluctuation_suppression/state is exist:0
[2026-08-08 20:29:06.528 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:06.528 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:06.593 UTC] [V] 485ChCtl <C1> StartDeviceCommunicationForOutputFluctuationSuppressionControlBroadcast 4 cnt:3604712, monitor_cnt:101, bc_elapsed:12, min:10, max:40
[2026-08-08 20:29:06.593 UTC] [V] 485DevCtl <C1:02> Dev not PCS IsNeedToChangeOControlState
[2026-08-08 20:29:06.593 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :1
[2026-08-08 20:29:06.594 UTC] [V] 485ChCtl <C1> send request:IMT01
[2026-08-08 20:29:06.595 UTC] [D] 485AcReq <C1:02> PutOStream [1][08000204000200019039]
[2026-08-08 20:29:06.598 UTC] [V] 485DevCtl <C3:01> AnalyzeResponseData proc restart cnt:360466 UPRstat:0
[2026-08-08 20:29:06.601 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-08 20:29:06.602 UTC] [D] 485DevCtl <C3:01> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-08 20:29:06.602 UTC] [D] 485DevCtl <C3:01> ResCnd OperationId [6] IsNormal[1] 
[2026-08-08 20:29:06.602 UTC] [V] 485DevCtl <C3:01> device_type:Battery
[2026-08-08 20:29:06.602 UTC] [V] 485ChCtl <C3> set rt:0
[2026-08-08 20:29:06.605 UTC] [V] 485ChCtl <C2> set rt:0
[2026-08-08 20:29:06.628 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:06.628 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:06.679 UTC] [V] OFSCtrl [/var/local/solajithome/function/output_fluctuation_suppression/batt_data] write success.
[2026-08-08 20:29:06.728 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:06.728 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:06.828 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:06.828 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:06.924 UTC] [V] 485DevCtl <C1:02> AnalyzeResponseData proc restart cnt:360460 UPRstat:0
[2026-08-08 20:29:06.924 UTC] [V] Res no response condition. set normal condition.
[2026-08-08 20:29:06.924 UTC] [D] 485DevCtl <C1:02> RcvDat status[2] len[7] [02040202067c52]
[2026-08-08 20:29:06.925 UTC] [D] 485DevCtl <C1:02> ResCnd OperationId [1] IsNormal[1] 
[2026-08-08 20:29:06.925 UTC] [V] 485DevCtl <C1:02> [01][431005][268.000000][1][°C]
[2026-08-08 20:29:06.925 UTC] [V] SummDat SetVrmValue dev_id:2 val:26800.000000 sc:3
[2026-08-08 20:29:06.926 UTC] [V] OCMgr SetMeterValue PhId:0102, branchNo:01, valueId:431005, value:268.000000, scaleFactor:1, devId:2
[2026-08-08 20:29:06.926 UTC] [V] 485DevCtl <C1:02> device_type:
[2026-08-08 20:29:06.926 UTC] [V] 485ChCtl <C1> set rt:0
[2026-08-08 20:29:06.927 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:06.928 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:06.993 UTC] [V] 485ChCtl <C1> StartDeviceCommunicationForOutputFluctuationSuppressionControlBroadcast 4 cnt:3604716, monitor_cnt:105, bc_elapsed:16, min:10, max:40
[2026-08-08 20:29:06.993 UTC] [V] 485DevCtl <C1:03> Dev not PCS IsNeedToChangeOControlState
[2026-08-08 20:29:06.994 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :1
[2026-08-08 20:29:06.994 UTC] [V] 485ChCtl <C1> send request:omron03
[2026-08-08 20:29:06.996 UTC] [D] 485AcReq <C1:03> PutOStream [1][08000303000000144427]
[2026-08-08 20:29:07.027 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:07.027 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:07.127 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:07.127 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:07.228 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:07.228 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:07.328 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:07.328 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:07.328 UTC] [V] OFSCtrl Control charge discharge proc start.
[2026-08-08 20:29:07.328 UTC] [V] OFSCtrl CHG 20 p_th(t):-1109.900000 = p_th_old_:-1100.000000 + lev_cd_:-0.300000 * (total_pcs_capacity_:99000.000000 * cof_spec_:2.000000 / 60 * (time_threshold_renew:10.000000 * 10)), min:-1100.000000, max:119300.000000
[2026-08-08 20:29:07.330 UTC] [V] OFSCtrl CHG 21 batt_w:278.807026 = old:282.244526 +  kp:0.550000 * e:-6.250000 + ki:0.000000 * sume:9163099.450228 + kd:0.040000 * (e:-6.250000 - e1:-6.250000)
[2026-08-08 20:29:07.331 UTC] [V] OFSCtrl CHG 29 q:2.000000, mod(round):1.000000
[2026-08-08 20:29:07.332 UTC] [D] OFSCtrl battery ctrl val:0.600000
[2026-08-08 20:29:07.332 UTC] [V] 485ChCtl <C3> battery limit on [3.000000,] request.
[2026-08-08 20:29:07.333 UTC] [V] OFSCtrl Control charge discharge proc:01->02->BATT_CHK->03->04->05->06->07->10->11->20->21->22->23->24->25->27->28->29->30->31->32->33->34
[2026-08-08 20:29:07.388 UTC] [V] 485DevCtl <C1:03> AnalyzeResponseData proc restart cnt:360460 UPRstat:0
[2026-08-08 20:29:07.388 UTC] [V] Res no response condition. set normal condition.
[2026-08-08 20:29:07.391 UTC] [D] 485DevCtl <C1:03> RcvDat status[2] len[45] [0303280000fe2d000100340000fff10000234e0000276500002e970000005f000002570010dbc800002b28794c]
[2026-08-08 20:29:07.392 UTC] [D] 485DevCtl <C1:03> ResCnd OperationId [1] IsNormal[1] 
[2026-08-08 20:29:07.393 UTC] [V] 485DevCtl <C1:03> [01][301200][65069.000000][1][V]
[2026-08-08 20:29:07.394 UTC] [V] SummDat SetVrmValue dev_id:3 val:6506900.000000 sc:3
[2026-08-08 20:29:07.400 UTC] [V] OCMgr SetMeterValue PhId:0103, branchNo:01, valueId:301200, value:65069.000000, scaleFactor:1, devId:3
[2026-08-08 20:29:07.408 UTC] [V] 485DevCtl <C1:03> [01][301201][9038.000000][3][A]
[2026-08-08 20:29:07.410 UTC] [V] SummDat SetVrmValue dev_id:3 val:9038.000000 sc:3
[2026-08-08 20:29:07.410 UTC] [V] OCMgr SetMeterValue PhId:0103, branchNo:01, valueId:301201, value:9038.000000, scaleFactor:3, devId:3
[2026-08-08 20:29:07.411 UTC] [V] OFSCtrl Rcv set p_grid:110480.000000
[2026-08-08 20:29:07.411 UTC] [V] 485DevCtl <C1:03> [01][601202][11048.000000][2][kW]
[2026-08-08 20:29:07.411 UTC] [V] SummDat SetVrmValue dev_id:3 val:110480.000000 sc:3
[2026-08-08 20:29:07.411 UTC] [V] OCMgr SetMeterValue PhId:0103, branchNo:01, valueId:601202, value:11048.000000, scaleFactor:2, devId:3
[2026-08-08 20:29:07.428 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:07.428 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:07.426 UTC] [V] 485DevCtl <C1:03> device_type:Grid-Meter
[2026-08-08 20:29:07.429 UTC] [V] 485ChCtl <C3> battery send request.1
[2026-08-08 20:29:07.430 UTC] [D] VarInf Limit_Bat rt[2]set val[3] set rate[0.600000] value100[500] value-100[-500]
[2026-08-08 20:29:07.431 UTC] [D] 485AcReq <C3:01> PutOStream [6][0f000001000000090110278e0001020003]
[2026-08-08 20:29:07.437 UTC] [V] 485ChCtl <C1> set rt:0
[2026-08-08 20:29:07.493 UTC] [V] 485ChCtl <C1> StartDeviceCommunicationForOutputFluctuationSuppressionControlBroadcast 4 cnt:3604721, monitor_cnt:110, bc_elapsed:21, min:10, max:40
[2026-08-08 20:29:07.510 UTC] [V] 485ChCtl <C2> StartDeviceCommunicationForOutputFluctuationSuppressionControlBroadcast 4 cnt:3604721, monitor_cnt:50, bc_elapsed:3604721, min:10, max:40
[2026-08-08 20:29:07.510 UTC] [V] OFSCtrl /var/local/solajithome/function/output_fluctuation_suppression/state is exist:0
[2026-08-08 20:29:07.510 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :9
[2026-08-08 20:29:07.511 UTC] [V] 485ChCtl <C2> send request:Sungrow08
[2026-08-08 20:29:07.513 UTC] [D] 485AcReq <C2:01> PutOStream [9][0800010413fa001794b1]
[2026-08-08 20:29:07.527 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:07.528 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:07.578 UTC] [V] 485DevCtl <C3:01> AnalyzeResponseData proc restart cnt:360467 UPRstat:0
[2026-08-08 20:29:07.580 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-08 20:29:07.581 UTC] [D] 485DevCtl <C3:01> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-08 20:29:07.581 UTC] [D] 485DevCtl <C3:01> ResCnd OperationId [6] IsNormal[1] 
[2026-08-08 20:29:07.581 UTC] [V] 485DevCtl <C3:01> device_type:Battery
[2026-08-08 20:29:07.581 UTC] [V] 485ChCtl <C3> set rt:0
[2026-08-08 20:29:07.593 UTC] [V] 485ChCtl <C1> StartDeviceCommunicationForOutputFluctuationSuppressionControlBroadcast 4 cnt:3604722, monitor_cnt:111, bc_elapsed:22, min:10, max:40
[2026-08-08 20:29:07.593 UTC] [V] 485DevCtl <C1:05> Dev not PCS IsNeedToChangeOControlState
[2026-08-08 20:29:07.593 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :1
[2026-08-08 20:29:07.594 UTC] [V] 485ChCtl <C1> send request:omron04
[2026-08-08 20:29:07.595 UTC] [D] 485AcReq <C1:05> PutOStream [1][0800050300030014b441]
[2026-08-08 20:29:07.627 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:07.627 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:07.679 UTC] [V] OFSCtrl [/var/local/solajithome/function/output_fluctuation_suppression/batt_data] write success.
[2026-08-08 20:29:07.728 UTC] [V] OFSCtrl limit chk 400 < 800 < [1076->1076] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:07.728 UTC] [V] OFSCtrl angif value:1076 power_val_:-1025.000000
[2026-08-08 20:29:07.828 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:07.828 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:07.879 UTC] [V] Res no response condition. set normal condition.
[2026-08-08 20:29:07.880 UTC] [D] 485DevCtl <C2:01> RcvDat status[2] len[51] [01042e000000000000000000000000ffffffffffffffff03e8ffffffff41060000ffffffffffffffffffffffffffffffff406b]
[2026-08-08 20:29:07.880 UTC] [D] 485DevCtl <C2:01> ResCnd OperationId [9] IsNormal[1] 
[2026-08-08 20:29:07.881 UTC] [V] 485DevCtl <C2:01> [04][101100][0.000000][1][V]
[2026-08-08 20:29:07.881 UTC] [V] SummDat SetVrmValue dev_id:7 val:0.000000 sc:3
[2026-08-08 20:29:07.881 UTC] [V] OCMgr SetMeterValue PhId:0201, branchNo:04, valueId:101100, value:0.000000, scaleFactor:1, devId:7
[2026-08-08 20:29:07.882 UTC] [V] 485DevCtl <C2:01> [04][101101][0.000000][1][A]
[2026-08-08 20:29:07.882 UTC] [V] SummDat SetVrmValue dev_id:7 val:0.000000 sc:3
[2026-08-08 20:29:07.882 UTC] [V] OCMgr SetMeterValue PhId:0201, branchNo:04, valueId:101101, value:0.000000, scaleFactor:1, devId:7
[2026-08-08 20:29:07.882 UTC] [V] 485DevCtl <C2:01> [05][101100][0.000000][1][V]
[2026-08-08 20:29:07.882 UTC] [V] SummDat SetVrmValue dev_id:7 val:0.000000 sc:3
[2026-08-08 20:29:07.883 UTC] [V] OCMgr SetMeterValue PhId:0201, branchNo:05, valueId:101100, value:0.000000, scaleFactor:1, devId:7
[2026-08-08 20:29:07.883 UTC] [V] 485DevCtl <C2:01> [05][101101][0.000000][1][A]
[2026-08-08 20:29:07.883 UTC] [V] SummDat SetVrmValue dev_id:7 val:0.000000 sc:3
[2026-08-08 20:29:07.883 UTC] [V] OCMgr SetMeterValue PhId:0201, branchNo:05, valueId:101101, value:0.000000, scaleFactor:1, devId:7
[2026-08-08 20:29:07.883 UTC] [V] 485DevCtl <C2:01> [06][101100][0.000000][1][V]
[2026-08-08 20:29:07.884 UTC] [V] SummDat SetVrmValue dev_id:7 val:0.000000 sc:3
[2026-08-08 20:29:07.884 UTC] [V] OCMgr SetMeterValue PhId:0201, branchNo:06, valueId:101100, value:0.000000, scaleFactor:1, devId:7
[2026-08-08 20:29:07.884 UTC] [V] 485DevCtl <C2:01> [06][101101][0.000000][1][A]
[2026-08-08 20:29:07.884 UTC] [V] SummDat SetVrmValue dev_id:7 val:0.000000 sc:3
[2026-08-08 20:29:07.909 UTC] [V] OCMgr SetMeterValue PhId:0201, branchNo:06, valueId:101101, value:0.000000, scaleFactor:1, devId:7
[2026-08-08 20:29:07.921 UTC] [V] 485DevCtl <C2:01> device_type:PV-PCS
[2026-08-08 20:29:07.928 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:07.928 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:07.931 UTC] [V] 485ChCtl <C2> set rt:0
[2026-08-08 20:29:07.991 UTC] [V] 485DevCtl <C1:05> AnalyzeResponseData proc restart cnt:360460 UPRstat:0
[2026-08-08 20:29:07.991 UTC] [V] Res no response condition. set normal condition.
[2026-08-08 20:29:07.993 UTC] [D] 485DevCtl <C1:05> RcvDat status[2] len[45] [05032800002090000015a9000016b7ffffffda00000257ffffdf3bffffffadffffb186ffffff380013853929aa]
[2026-08-08 20:29:07.993 UTC] [D] 485DevCtl <C1:05> ResCnd OperationId [1] IsNormal[1] 
[2026-08-08 20:29:07.993 UTC] [V] OFSCtrl Rcv set p_pv:-830.000000
[2026-08-08 20:29:07.993 UTC] [V] 485DevCtl <C1:05> [01][601259][-83.000000][2][kW]
[2026-08-08 20:29:07.993 UTC] [V] SummDat SetVrmValue dev_id:5 val:-830.000000 sc:3
[2026-08-08 20:29:07.994 UTC] [V] OCMgr SetMeterValue PhId:0105, branchNo:01, valueId:601259, value:-83.000000, scaleFactor:2, devId:5
[2026-08-08 20:29:07.999 UTC] [V] 485DevCtl <C1:05> [01][603259][1279289.000000][1][kWh]
[2026-08-08 20:29:08.001 UTC] [V] SummDat SetVrmValue dev_id:5 val:1279289.000000 sc:1
[2026-08-08 20:29:08.005 UTC] [V] OCMgr SetMeterValue PhId:0105, branchNo:01, valueId:603259, value:1279289.000000, scaleFactor:1, devId:5
[2026-08-08 20:29:08.009 UTC] [V] 485ChCtl <C2> StartDeviceCommunicationForOutputFluctuationSuppressionControlBroadcast 4 cnt:3604726, monitor_cnt:55, bc_elapsed:3604726, min:10, max:40
[2026-08-08 20:29:08.010 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :10
[2026-08-08 20:29:08.010 UTC] [V] 485ChCtl <C2> send request:Sungrow08
[2026-08-08 20:29:08.011 UTC] [D] 485AcReq <C2:02> PutOStream [10][0800020413d80002f547]
[2026-08-08 20:29:08.009 UTC] [V] 485DevCtl <C1:05> device_type:PV-Meter
[2026-08-08 20:29:08.019 UTC] [V] 485ChCtl <C1> set rt:0
[2026-08-08 20:29:08.028 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:08.028 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:08.093 UTC] [V] 485ChCtl <C1> StartDeviceCommunicationForOutputFluctuationSuppressionControlBroadcast 4 cnt:3604727, monitor_cnt:116, bc_elapsed:27, min:10, max:40
[2026-08-08 20:29:08.093 UTC] [V] 485DevCtl <C1:06> Dev not PCS IsNeedToChangeOControlState
[2026-08-08 20:29:08.093 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :1
[2026-08-08 20:29:08.094 UTC] [V] 485ChCtl <C1> send request:omron06
[2026-08-08 20:29:08.096 UTC] [D] 485AcReq <C1:06> PutOStream [1][08000603000000144472]
[2026-08-08 20:29:08.128 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:08.128 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:08.227 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:08.228 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:08.327 UTC] [V] OFSCtrl limit chk 400 < 800 < [1076->1076] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:08.328 UTC] [V] OFSCtrl angif value:1076 power_val_:-1025.000000
[2026-08-08 20:29:08.328 UTC] [V] OFSCtrl Control charge discharge proc start.
[2026-08-08 20:29:08.328 UTC] [V] OFSCtrl CHG 20 p_th(t):-1109.900000 = p_th_old_:-1100.000000 + lev_cd_:-0.300000 * (total_pcs_capacity_:99000.000000 * cof_spec_:2.000000 / 60 * (time_threshold_renew:10.000000 * 10)), min:-1100.000000, max:119300.000000
[2026-08-08 20:29:08.328 UTC] [V] OFSCtrl CHG 21 batt_w:234.807026 = old:278.807026 +  kp:0.550000 * e:-75.000000 + ki:0.000000 * sume:9163024.450228 + kd:0.040000 * (e:-75.000000 - e1:-6.250000)
[2026-08-08 20:29:08.329 UTC] [V] OFSCtrl CHG 29 q:2.000000, mod(round):0.000000
[2026-08-08 20:29:08.330 UTC] [D] OFSCtrl battery ctrl val:0.500000
[2026-08-08 20:29:08.330 UTC] [V] 485ChCtl <C3> battery limit on [2.000000,] request.
[2026-08-08 20:29:08.330 UTC] [V] OFSCtrl Control charge discharge proc:01->02->BATT_CHK->03->04->05->06->07->10->11->20->21->22->23->24->25->27->28->29->30->31->32->33->34
[2026-08-08 20:29:08.337 UTC] [V] Res no response condition. set normal condition.
[2026-08-08 20:29:08.337 UTC] [D] 485DevCtl <C2:02> RcvDat status[2] len[9] [02040400100000c941]
[2026-08-08 20:29:08.338 UTC] [D] 485DevCtl <C2:02> ResCnd OperationId [10] IsNormal[1] 
[2026-08-08 20:29:08.338 UTC] [V] 485DevCtl <C2:02> device_type:PV-PCS
[2026-08-08 20:29:08.339 UTC] [V] 485ChCtl <C2> set rt:0
[2026-08-08 20:29:08.339 UTC] [D] 485ChCtl <C2> monitoring dev All Send
[2026-08-08 20:29:08.427 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:08.427 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:08.430 UTC] [V] 485ChCtl <C3> battery send request.1
[2026-08-08 20:29:08.430 UTC] [D] VarInf Limit_Bat rt[2]set val[2] set rate[0.400000] value100[500] value-100[-500]
[2026-08-08 20:29:08.432 UTC] [D] 485AcReq <C3:01> PutOStream [6][0f000001000000090110278e0001020002]
[2026-08-08 20:29:08.490 UTC] [V] 485DevCtl <C1:06> AnalyzeResponseData proc restart cnt:360460 UPRstat:0
[2026-08-08 20:29:08.491 UTC] [V] Res no response condition. set normal condition.
[2026-08-08 20:29:08.492 UTC] [D] 485DevCtl <C1:06> RcvDat status[2] len[45] [06032800000804000008120000081100000a6200000a5a000008f5000000640000025700000af80000001c3b87]
[2026-08-08 20:29:08.492 UTC] [D] 485DevCtl <C1:06> ResCnd OperationId [1] IsNormal[1] 
[2026-08-08 20:29:08.492 UTC] [V] OFSCtrl Rcv set p_batt:280.000000
[2026-08-08 20:29:08.493 UTC] [V] 485DevCtl <C1:06> [01][601237][28.000000][2][kW]
[2026-08-08 20:29:08.493 UTC] [V] SummDat SetVrmValue dev_id:6 val:280.000000 sc:3
[2026-08-08 20:29:08.494 UTC] [V] OCMgr SetMeterValue PhId:0106, branchNo:01, valueId:601237, value:28.000000, scaleFactor:2, devId:6
[2026-08-08 20:29:08.494 UTC] [V] 485DevCtl <C1:06> device_type:Batt-Meter
[2026-08-08 20:29:08.495 UTC] [V] 485ChCtl <C1> set rt:0
[2026-08-08 20:29:08.500 UTC] [D] 485ChCtl <C1> monitoring dev All Send
[2026-08-08 20:29:08.527 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:08.527 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:08.587 UTC] [V] 485DevCtl <C3:01> AnalyzeResponseData proc restart cnt:360468 UPRstat:0
[2026-08-08 20:29:08.589 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-08 20:29:08.590 UTC] [D] 485DevCtl <C3:01> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-08 20:29:08.590 UTC] [D] 485DevCtl <C3:01> ResCnd OperationId [6] IsNormal[1] 
[2026-08-08 20:29:08.590 UTC] [V] 485DevCtl <C3:01> device_type:Battery
[2026-08-08 20:29:08.590 UTC] [V] 485ChCtl <C3> set rt:0
[2026-08-08 20:29:08.628 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:08.628 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:08.679 UTC] [V] OFSCtrl [/var/local/solajithome/function/output_fluctuation_suppression/batt_data] write success.
[2026-08-08 20:29:08.728 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:08.728 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:08.828 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:08.828 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:08.928 UTC] [V] OFSCtrl limit chk 400 < 800 < [1072->1072] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:08.928 UTC] [V] OFSCtrl angif value:1072 power_val_:-1300.000000
[2026-08-08 20:29:09.027 UTC] [V] OFSCtrl limit chk 400 < 800 < [1072->1072] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:09.028 UTC] [V] OFSCtrl angif value:1072 power_val_:-1300.000000
[2026-08-08 20:29:09.127 UTC] [V] OFSCtrl limit chk 400 < 800 < [1072->1072] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:09.127 UTC] [V] OFSCtrl angif value:1072 power_val_:-1300.000000
[2026-08-08 20:29:09.228 UTC] [V] OFSCtrl limit chk 400 < 800 < [1072->1072] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:09.228 UTC] [V] OFSCtrl angif value:1072 power_val_:-1300.000000
[2026-08-08 20:29:09.328 UTC] [V] OFSCtrl limit chk 400 < 800 < [1072->1072] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:09.328 UTC] [V] OFSCtrl angif value:1072 power_val_:-1300.000000
[2026-08-08 20:29:09.328 UTC] [V] OFSCtrl Control charge discharge proc start.
[2026-08-08 20:29:09.328 UTC] [V] OFSCtrl CHG 20 p_th(t):-1109.900000 = p_th_old_:-1100.000000 + lev_cd_:-0.300000 * (total_pcs_capacity_:99000.000000 * cof_spec_:2.000000 / 60 * (time_threshold_renew:10.000000 * 10)), min:-1100.000000, max:119300.000000
[2026-08-08 20:29:09.329 UTC] [V] OFSCtrl CHG 21 batt_w:355.807026 = old:234.807026 +  kp:0.550000 * e:200.000000 + ki:0.000000 * sume:9163224.450228 + kd:0.040000 * (e:200.000000 - e1:-75.000000)
[2026-08-08 20:29:09.329 UTC] [V] OFSCtrl CHG 29 q:3.000000, mod(round):1.000000
[2026-08-08 20:29:09.329 UTC] [D] OFSCtrl battery ctrl val:0.700000
[2026-08-08 20:29:09.330 UTC] [V] 485ChCtl <C3> battery send request.1
[2026-08-08 20:29:09.330 UTC] [D] VarInf Limit_Bat rt[2]set val[4] set rate[0.800000] value100[500] value-100[-500]
[2026-08-08 20:29:09.332 UTC] [D] 485AcReq <C3:01> PutOStream [6][0f000001000000090110278e0001020004]
[2026-08-08 20:29:09.329 UTC] [V] 485ChCtl <C3> battery limit on [4.000000,] request.
[2026-08-08 20:29:09.335 UTC] [V] OFSCtrl Control charge discharge proc:01->02->BATT_CHK->03->04->05->06->07->10->11->20->21->22->23->24->25->27->28->29->30->31->32->33->34
[2026-08-08 20:29:09.428 UTC] [V] OFSCtrl limit chk 400 < 800 < [1072->1072] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:09.428 UTC] [V] OFSCtrl angif value:1072 power_val_:-1300.000000
[2026-08-08 20:29:09.477 UTC] [V] 485DevCtl <C3:01> AnalyzeResponseData proc restart cnt:360468 UPRstat:0
[2026-08-08 20:29:09.479 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-08 20:29:09.479 UTC] [D] 485DevCtl <C3:01> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-08 20:29:09.479 UTC] [D] 485DevCtl <C3:01> ResCnd OperationId [6] IsNormal[1] 
[2026-08-08 20:29:09.479 UTC] [V] 485DevCtl <C3:01> device_type:Battery
[2026-08-08 20:29:09.480 UTC] [V] 485ChCtl <C3> set rt:0
[2026-08-08 20:29:09.528 UTC] [V] OFSCtrl limit chk 400 < 800 < [1072->1072] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:09.528 UTC] [V] OFSCtrl angif value:1072 power_val_:-1300.000000
[2026-08-08 20:29:09.628 UTC] [V] OFSCtrl limit chk 400 < 800 < [1072->1072] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:09.628 UTC] [V] OFSCtrl angif value:1072 power_val_:-1300.000000
[2026-08-08 20:29:09.679 UTC] [V] OFSCtrl [/var/local/solajithome/function/output_fluctuation_suppression/batt_data] write success.
[2026-08-08 20:29:09.728 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:09.728 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:09.827 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:09.828 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:09.927 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:09.928 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:10.027 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:10.027 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:10.127 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:10.127 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:10.227 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:10.228 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:10.328 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:10.328 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:10.328 UTC] [V] OFSCtrl Control charge discharge proc start.
[2026-08-08 20:29:10.328 UTC] [V] OFSCtrl CHG 20 p_th(t):-1109.900000 = p_th_old_:-1100.000000 + lev_cd_:-0.300000 * (total_pcs_capacity_:99000.000000 * cof_spec_:2.000000 / 60 * (time_threshold_renew:10.000000 * 10)), min:-1100.000000, max:119300.000000
[2026-08-08 20:29:10.329 UTC] [V] OFSCtrl CHG 21 batt_w:344.119526 = old:355.807026 +  kp:0.550000 * e:-6.250000 + ki:0.000000 * sume:9163218.200228 + kd:0.040000 * (e:-6.250000 - e1:200.000000)
[2026-08-08 20:29:10.329 UTC] [V] OFSCtrl CHG 29 q:3.000000, mod(round):0.000000
[2026-08-08 20:29:10.329 UTC] [D] OFSCtrl battery ctrl val:0.700000
[2026-08-08 20:29:10.329 UTC] [V] 485ChCtl <C3> battery limit on [3.000000,] request.
[2026-08-08 20:29:10.329 UTC] [V] OFSCtrl Control charge discharge proc:01->02->BATT_CHK->03->04->05->06->07->10->11->20->21->22->23->24->25->27->28->29->30->31->32->33->34
[2026-08-08 20:29:10.329 UTC] [V] 485ChCtl <C3> battery send request.1
[2026-08-08 20:29:10.330 UTC] [D] VarInf Limit_Bat rt[2]set val[3] set rate[0.600000] value100[500] value-100[-500]
[2026-08-08 20:29:10.331 UTC] [D] 485AcReq <C3:01> PutOStream [6][0f000001000000090110278e0001020003]
[2026-08-08 20:29:10.393 UTC] [V] 485DevCtl <C1:01> device_type:Irr-Meter
[2026-08-08 20:29:10.394 UTC] [V] 485DevCtl <C1:01> device_type:Irr-Meter
[2026-08-08 20:29:10.394 UTC] [V] 485ChCtl <C1> fixed cycle Irr-Meter
[2026-08-08 20:29:10.394 UTC] [V] 485DevCtl <C1:01> Dev not PCS IsNeedToChangeOControlState
[2026-08-08 20:29:10.394 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :1
[2026-08-08 20:29:10.395 UTC] [V] 485ChCtl <C1> send request:Irr01
[2026-08-08 20:29:10.396 UTC] [D] 485AcReq <C1:01> PutOStream [1][080001040000000271cb]
[2026-08-08 20:29:10.428 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:10.428 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:10.497 UTC] [V] 485DevCtl <C3:01> AnalyzeResponseData proc restart cnt:360469 UPRstat:0
[2026-08-08 20:29:10.499 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-08 20:29:10.500 UTC] [D] 485DevCtl <C3:01> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-08 20:29:10.500 UTC] [D] 485DevCtl <C3:01> ResCnd OperationId [6] IsNormal[1] 
[2026-08-08 20:29:10.500 UTC] [V] 485DevCtl <C3:01> device_type:Battery
[2026-08-08 20:29:10.500 UTC] [V] 485ChCtl <C3> set rt:0
[2026-08-08 20:29:10.528 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:10.528 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:10.628 UTC] [V] OFSCtrl limit chk 400 < 800 < [1076->1076] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:10.628 UTC] [V] OFSCtrl angif value:1076 power_val_:-1025.000000
[2026-08-08 20:29:10.679 UTC] [V] OFSCtrl [/var/local/solajithome/function/output_fluctuation_suppression/batt_data] write success.
[2026-08-08 20:29:10.726 UTC] [V] 485DevCtl <C1:01> AnalyzeResponseData proc restart cnt:360471 UPRstat:0
[2026-08-08 20:29:10.727 UTC] [V] Res no response condition. set normal condition.
[2026-08-08 20:29:10.728 UTC] [V] OFSCtrl limit chk 400 < 800 < [1076->1076] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:10.728 UTC] [V] OFSCtrl angif value:1076 power_val_:-1025.000000
[2026-08-08 20:29:10.728 UTC] [D] 485DevCtl <C1:01> RcvDat status[2] len[9] [010404000002013b24]
[2026-08-08 20:29:10.728 UTC] [D] 485DevCtl <C1:01> ResCnd OperationId [1] IsNormal[1] 
[2026-08-08 20:29:10.729 UTC] [V] OFSCtrl Rcv set flux_of_solar:0.000000
[2026-08-08 20:29:10.729 UTC] [V] 485DevCtl <C1:01> [01][401006][0.000000][1][W/m2]
[2026-08-08 20:29:10.729 UTC] [V] SummDat SetVrmValue dev_id:1 val:0.000000 sc:3
[2026-08-08 20:29:10.729 UTC] [V] OCMgr SetMeterValue PhId:0101, branchNo:01, valueId:401006, value:0.000000, scaleFactor:1, devId:1
[2026-08-08 20:29:10.730 UTC] [V] 485ChCtl <C3> StartDeviceCommunicationForOutputFluctuationSuppressionControlBroadcast 4 cnt:3604753, monitor_cnt:50, bc_elapsed:3604753, min:10, max:40
[2026-08-08 20:29:10.730 UTC] [V] OFSCtrl /var/local/solajithome/function/output_fluctuation_suppression/state is exist:0
[2026-08-08 20:29:10.730 UTC] [V] 485DevCtl <C3:01> Dev not PCS IsNeedToChangeOControlState
[2026-08-08 20:29:10.730 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :5
[2026-08-08 20:29:10.732 UTC] [V] 485ChCtl <C3> send request:Sungrow11
[2026-08-08 20:29:10.733 UTC] [D] 485AcReq <C3:01> PutOStream [5][0c00000100000006010469780001]
[2026-08-08 20:29:10.735 UTC] [V] 485DevCtl <C1:01> [01][421005][263.000000][1][℃]
[2026-08-08 20:29:10.735 UTC] [V] SummDat SetVrmValue dev_id:1 val:26300.000000 sc:3
[2026-08-08 20:29:10.736 UTC] [V] OCMgr SetMeterValue PhId:0101, branchNo:01, valueId:421005, value:263.000000, scaleFactor:1, devId:1
[2026-08-08 20:29:10.736 UTC] [V] 485DevCtl <C1:01> device_type:Irr-Meter
[2026-08-08 20:29:10.736 UTC] [V] OFSCtrl Irr-Meter received.
[2026-08-08 20:29:10.737 UTC] [V] 485ChCtl <C1> set rt:0
[2026-08-08 20:29:10.740 UTC] [V] 485DevCtl <C1:01> device_type:Irr-Meter
[2026-08-08 20:29:10.794 UTC] [V] 485DevCtl <C1:04> device_type:CO-Meter
[2026-08-08 20:29:10.795 UTC] [V] 485DevCtl <C1:04> device_type:CO-Meter
[2026-08-08 20:29:10.795 UTC] [V] 485ChCtl <C1> fixed cycle CO-Meter
[2026-08-08 20:29:10.795 UTC] [V] 485DevCtl <C1:04> Dev not PCS IsNeedToChangeOControlState
[2026-08-08 20:29:10.795 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :1
[2026-08-08 20:29:10.796 UTC] [V] 485ChCtl <C1> send request:omron05
[2026-08-08 20:29:10.797 UTC] [D] 485AcReq <C1:04> PutOStream [1][0800040300030014b590]
[2026-08-08 20:29:10.827 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:10.828 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:10.867 UTC] [V] 485DevCtl <C3:01> AnalyzeResponseData proc restart cnt:360470 UPRstat:0
[2026-08-08 20:29:10.868 UTC] [D] 485DevCtl <C3:01> RcvDat status[0] len[11] [0001000000050104020128]
[2026-08-08 20:29:10.869 UTC] [D] 485DevCtl <C3:01> ResCnd OperationId [5] IsNormal[1]  ConditionType [lggrdev:Normal] Action[-1]
[2026-08-08 20:29:10.869 UTC] [V] 485DevCtl <C3:01> [01][121005][296.000000][1][℃]
[2026-08-08 20:29:10.869 UTC] [V] SummDat SetVrmValue dev_id:9 val:29600.000000 sc:3
[2026-08-08 20:29:10.870 UTC] [V] OCMgr SetMeterValue PhId:0301, branchNo:01, valueId:121005, value:296.000000, scaleFactor:1, devId:9
[2026-08-08 20:29:10.870 UTC] [V] 485DevCtl <C3:01> device_type:Battery
[2026-08-08 20:29:10.871 UTC] [V] 485ChCtl <C3> set rt:0
[2026-08-08 20:29:10.874 UTC] [D] 485ChCtl <C3> monitoring dev All Send
[2026-08-08 20:29:10.927 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:10.927 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:11.027 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:11.027 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:11.128 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:11.128 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:11.197 UTC] [V] 485DevCtl <C1:04> AnalyzeResponseData proc restart cnt:360470 UPRstat:0
[2026-08-08 20:29:11.197 UTC] [V] Res no response condition. set normal condition.
[2026-08-08 20:29:11.199 UTC] [D] 485DevCtl <C1:04> RcvDat status[2] len[45] [0403280000221f000017f9000017f0ffffffe400000257ffffe848ffffffc4ffffaf7affffff3200121a81d899]
[2026-08-08 20:29:11.199 UTC] [D] 485DevCtl <C1:04> ResCnd OperationId [1] IsNormal[1] 
[2026-08-08 20:29:11.199 UTC] [V] OFSCtrl Rcv set p_co:-600.000000, p_co_old:-600.000000
[2026-08-08 20:29:11.199 UTC] [V] 485DevCtl <C1:04> [01][601260][-60.000000][2][kW]
[2026-08-08 20:29:11.200 UTC] [V] SummDat SetVrmValue dev_id:4 val:-600.000000 sc:3
[2026-08-08 20:29:11.200 UTC] [V] OCMgr SetMeterValue PhId:0104, branchNo:01, valueId:601260, value:-60.000000, scaleFactor:2, devId:4
[2026-08-08 20:29:11.200 UTC] [V] 485DevCtl <C1:04> [01][603260][1186433.000000][1][kWh]
[2026-08-08 20:29:11.200 UTC] [V] SummDat SetVrmValue dev_id:4 val:1186433.000000 sc:1
[2026-08-08 20:29:11.201 UTC] [V] OCMgr SetMeterValue PhId:0104, branchNo:01, valueId:603260, value:1186433.000000, scaleFactor:1, devId:4
[2026-08-08 20:29:11.201 UTC] [V] 485DevCtl <C1:04> device_type:CO-Meter
[2026-08-08 20:29:11.201 UTC] [V] OFSCtrl km50 received.
[2026-08-08 20:29:11.201 UTC] [V] OFSCtrl omron05_local_date :2026/08/09 ? 2026/08/09
[2026-08-08 20:29:11.201 UTC] [V] OFSCtrl omron05_local_time :2026/08/09 05 ? 2026/08/09 05
[2026-08-08 20:29:11.201 UTC] [V] OFSCtrl out of control time.
[2026-08-08 20:29:11.202 UTC] [V] OFSCtrl Control pv-pcs proc start.
[2026-08-08 20:29:11.202 UTC] [V] OFSCtrl NOD_month:-1664.000000 = (NOD_month:306 - ((nod_max_/30):23.333333 * (cnt-1):25) * (30/cnt):6.000000 
[2026-08-08 20:29:11.202 UTC] [V] OFSCtrl PCS ratio_month:232.646617 = -k_inhibition_ratio_month:-0.097744 * NOD_month:-1664.000000 + inhibition_ratio_max:70
[2026-08-08 20:29:11.202 UTC] [V] OFSCtrl PCS 05 inhibition_ratio:70.000000 = max(ratio_min:5, min(ratio:70, ratio_hour:70.000000, ratio_day:70.000000, ratio_month:232.646617))
[2026-08-08 20:29:11.202 UTC] [D] OFSCtrl pv-pcs ctrl val:0.000000 old:0.000000
[2026-08-08 20:29:11.203 UTC] [V] OCHisDB set rate:0 t_rate:0 cnt:49
[2026-08-08 20:29:11.203 UTC] [V] 485ChCtl <C2> pv-pcs limit on [0.000000] request.
[2026-08-08 20:29:11.203 UTC] [V] OFSCtrl Control pv-pcs proc:BATT_CHK->01->02->03->04->05->06->07->09->09->10->11->12
[2026-08-08 20:29:11.203 UTC] [V] OFSCtrl Nod calc proc start.
[2026-08-08 20:29:11.203 UTC] [V] OFSCtrl ProcNodCountCalculation culc nod skip stop:0, pause:0, ctl_time:0
[2026-08-08 20:29:11.209 UTC] [V] 485ChCtl <C2> pv-pcs send request.
[2026-08-08 20:29:11.209 UTC] [D] VarInf update ofs_rate:0.000000
[2026-08-08 20:29:11.210 UTC] [V] VarInf LimitSet rt[2] val[170] key[ValueOn]
[2026-08-08 20:29:11.210 UTC] [D] VarInf output_mode:8
[2026-08-08 20:29:11.210 UTC] [D] VarInf update ofs_rate:0.000000
[2026-08-08 20:29:11.210 UTC] [D] VarInf Limit setRate[0.000000] rate[0.000000] value100[1000.000000] value0[0.000000]
[2026-08-08 20:29:11.210 UTC] [V] 485DevCtl <C2:01> ChangeOutputRateToDevice rate:0.000000 set_rate1
[2026-08-08 20:29:11.210 UTC] [D] VarInf Limit rt[2] int_set_rate[1] server_rate[0.000000] rated_output[100.000000] solar_battery_power[100.000000]
[2026-08-08 20:29:11.211 UTC] [D] 485AcReq <C2:01> PutOStreamForBc [3][0d000010138e00020400aa0001466f]
[2026-08-08 20:29:11.228 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:11.228 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:11.236 UTC] [V] OFSCtrl update p_co_old:-600.000000
[2026-08-08 20:29:11.236 UTC] [V] OFSCtrl Nod calc proc:
[2026-08-08 20:29:11.238 UTC] [V] 485ChCtl <C1> set rt:0
[2026-08-08 20:29:11.239 UTC] [V] 485DevCtl <C1:04> device_type:CO-Meter
[2026-08-08 20:29:11.328 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:11.328 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:11.328 UTC] [V] OFSCtrl Control charge discharge proc start.
[2026-08-08 20:29:11.328 UTC] [V] OFSCtrl CHG 20 p_th(t):-1109.900000 = p_th_old_:-1100.000000 + lev_cd_:-0.300000 * (total_pcs_capacity_:99000.000000 * cof_spec_:2.000000 / 60 * (time_threshold_renew:10.000000 * 10)), min:-1100.000000, max:119300.000000
[2026-08-08 20:29:11.329 UTC] [V] OFSCtrl CHG 21 batt_w:340.682026 = old:344.119526 +  kp:0.550000 * e:-6.250000 + ki:0.000000 * sume:9163211.950228 + kd:0.040000 * (e:-6.250000 - e1:-6.250000)
[2026-08-08 20:29:11.329 UTC] [V] OFSCtrl CHG 29 q:3.000000, mod(round):0.000000
[2026-08-08 20:29:11.329 UTC] [D] OFSCtrl battery ctrl val:0.700000
[2026-08-08 20:29:11.330 UTC] [V] 485ChCtl <C3> battery limit on [3.000000,] request.
[2026-08-08 20:29:11.330 UTC] [V] OFSCtrl Control charge discharge proc:01->02->BATT_CHK->03->04->05->06->07->10->11->20->21->22->23->24->25->27->28->29->30->31->32->33->34
[2026-08-08 20:29:11.427 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:11.428 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:11.429 UTC] [V] 485ChCtl <C3> battery send request.1
[2026-08-08 20:29:11.430 UTC] [D] VarInf Limit_Bat rt[2]set val[3] set rate[0.600000] value100[500] value-100[-500]
[2026-08-08 20:29:11.432 UTC] [D] 485AcReq <C3:01> PutOStream [6][0f000001000000090110278e0001020003]
[2026-08-08 20:29:11.505 UTC] [V] 485ChCtl <C2> set rt:0
[2026-08-08 20:29:11.528 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:11.528 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:11.577 UTC] [V] 485DevCtl <C3:01> AnalyzeResponseData proc restart cnt:360471 UPRstat:0
[2026-08-08 20:29:11.581 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-08 20:29:11.584 UTC] [D] 485DevCtl <C3:01> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-08 20:29:11.585 UTC] [D] 485DevCtl <C3:01> ResCnd OperationId [6] IsNormal[1] 
[2026-08-08 20:29:11.586 UTC] [V] 485DevCtl <C3:01> device_type:Battery
[2026-08-08 20:29:11.590 UTC] [V] 485ChCtl <C3> set rt:0
[2026-08-08 20:29:11.628 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:11.628 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:11.679 UTC] [V] OFSCtrl [/var/local/solajithome/function/output_fluctuation_suppression/batt_data] write success.
[2026-08-08 20:29:11.728 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:11.728 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:11.828 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:11.828 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:11.927 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:11.928 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:12.028 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:12.028 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:12.127 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:12.128 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:12.227 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:12.228 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:12.328 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:12.328 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:12.328 UTC] [V] OFSCtrl Control charge discharge proc start.
[2026-08-08 20:29:12.328 UTC] [V] OFSCtrl CHG 20 p_th(t):-1109.900000 = p_th_old_:-1100.000000 + lev_cd_:-0.300000 * (total_pcs_capacity_:99000.000000 * cof_spec_:2.000000 / 60 * (time_threshold_renew:10.000000 * 10)), min:-1100.000000, max:119300.000000
[2026-08-08 20:29:12.329 UTC] [V] OFSCtrl CHG 21 batt_w:337.244526 = old:340.682026 +  kp:0.550000 * e:-6.250000 + ki:0.000000 * sume:9163205.700228 + kd:0.040000 * (e:-6.250000 - e1:-6.250000)
[2026-08-08 20:29:12.329 UTC] [V] OFSCtrl CHG 29 q:3.000000, mod(round):0.000000
[2026-08-08 20:29:12.329 UTC] [D] OFSCtrl battery ctrl val:0.700000
[2026-08-08 20:29:12.331 UTC] [V] 485ChCtl <C3> battery limit on [3.000000,] request.
[2026-08-08 20:29:12.331 UTC] [V] OFSCtrl Control charge discharge proc:01->02->BATT_CHK->03->04->05->06->07->10->11->20->21->22->23->24->25->27->28->29->30->31->32->33->34
[2026-08-08 20:29:12.427 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:12.428 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:12.429 UTC] [V] 485ChCtl <C3> battery send request.1
[2026-08-08 20:29:12.430 UTC] [D] VarInf Limit_Bat rt[2]set val[3] set rate[0.600000] value100[500] value-100[-500]
[2026-08-08 20:29:12.432 UTC] [D] 485AcReq <C3:01> PutOStream [6][0f000001000000090110278e0001020003]
[2026-08-08 20:29:12.527 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:12.528 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:12.587 UTC] [V] 485DevCtl <C3:01> AnalyzeResponseData proc restart cnt:360472 UPRstat:0
[2026-08-08 20:29:12.589 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-08 20:29:12.590 UTC] [D] 485DevCtl <C3:01> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-08 20:29:12.590 UTC] [D] 485DevCtl <C3:01> ResCnd OperationId [6] IsNormal[1] 
[2026-08-08 20:29:12.590 UTC] [V] 485DevCtl <C3:01> device_type:Battery
[2026-08-08 20:29:12.590 UTC] [V] 485ChCtl <C3> set rt:0
[2026-08-08 20:29:12.627 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:12.627 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:12.679 UTC] [V] OFSCtrl [/var/local/solajithome/function/output_fluctuation_suppression/batt_data] write success.
[2026-08-08 20:29:12.727 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:12.727 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:12.827 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:12.827 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:12.927 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:12.927 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:13.010 UTC] [V] 485ChCtl <C2> StartDeviceCommunicationForOutputFluctuationSuppressionControlBroadcast 4 cnt:3604776, monitor_cnt:50, bc_elapsed:3604776, min:10, max:40
[2026-08-08 20:29:13.010 UTC] [V] OFSCtrl /var/local/solajithome/function/output_fluctuation_suppression/state is exist:0
[2026-08-08 20:29:13.010 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :1
[2026-08-08 20:29:13.011 UTC] [V] 485ChCtl <C2> send request:Sungrow08
[2026-08-08 20:29:13.012 UTC] [D] 485AcReq <C2:01> PutOStream [1][08000104138a0024d57f]
[2026-08-08 20:29:13.027 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:13.027 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:13.127 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:13.127 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:13.227 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:13.227 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:13.327 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:13.327 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:13.327 UTC] [V] OFSCtrl Control charge discharge proc start.
[2026-08-08 20:29:13.328 UTC] [V] OFSCtrl CHG 20 p_th(t):-1109.900000 = p_th_old_:-1100.000000 + lev_cd_:-0.300000 * (total_pcs_capacity_:99000.000000 * cof_spec_:2.000000 / 60 * (time_threshold_renew:10.000000 * 10)), min:-1100.000000, max:119300.000000
[2026-08-08 20:29:13.328 UTC] [V] OFSCtrl CHG 21 batt_w:333.807026 = old:337.244526 +  kp:0.550000 * e:-6.250000 + ki:0.000000 * sume:9163199.450228 + kd:0.040000 * (e:-6.250000 - e1:-6.250000)
[2026-08-08 20:29:13.328 UTC] [V] OFSCtrl CHG 29 q:3.000000, mod(round):0.000000
[2026-08-08 20:29:13.329 UTC] [D] OFSCtrl battery ctrl val:0.700000
[2026-08-08 20:29:13.329 UTC] [V] 485ChCtl <C3> battery limit on [3.000000,] request.
[2026-08-08 20:29:13.329 UTC] [V] OFSCtrl Control charge discharge proc:01->02->BATT_CHK->03->04->05->06->07->10->11->20->21->22->23->24->25->27->28->29->30->31->32->33->34
[2026-08-08 20:29:13.329 UTC] [V] 485ChCtl <C3> battery send request.1
[2026-08-08 20:29:13.330 UTC] [D] VarInf Limit_Bat rt[2]set val[3] set rate[0.600000] value100[500] value-100[-500]
[2026-08-08 20:29:13.331 UTC] [D] 485AcReq <C3:01> PutOStream [6][0f000001000000090110278e0001020003]
[2026-08-08 20:29:13.410 UTC] [V] Res no response condition. set normal condition.
[2026-08-08 20:29:13.413 UTC] [D] 485DevCtl <C2:01> RcvDat status[2] len[77] [0104480000fcc00000172b000000000000000000000000000000000000000000000000000000000000000000000000ffffffffffffffffffffffff000000000000000000000000000014002f98]
[2026-08-08 20:29:13.413 UTC] [D] 485DevCtl <C2:01> ResCnd OperationId [1] IsNormal[1] 
[2026-08-08 20:29:13.414 UTC] [V] 485DevCtl <C2:01> [01][115202][0.000000][1][kWh]
[2026-08-08 20:29:13.414 UTC] [V] SummDat SetVrmValue dev_id:7 val:0.000000 sc:1
[2026-08-08 20:29:13.414 UTC] [V] OCMgr SetMeterValue PhId:0201, branchNo:01, valueId:115202, value:0.000000, scaleFactor:1, devId:7
[2026-08-08 20:29:13.414 UTC] [V] 485DevCtl <C2:01> [01][113202][64704.000000][0][kWh]
[2026-08-08 20:29:13.415 UTC] [V] SummDat SetVrmValue dev_id:7 val:64704.000000 sc:0
[2026-08-08 20:29:13.415 UTC] [V] OCMgr SetMeterValue PhId:0201, branchNo:01, valueId:113202, value:64704.000000, scaleFactor:0, devId:7
[2026-08-08 20:29:13.415 UTC] [V] 485DevCtl <C2:01> [01][121005][0.000000][1][℃]
[2026-08-08 20:29:13.415 UTC] [V] SummDat SetVrmValue dev_id:7 val:0.000000 sc:3
[2026-08-08 20:29:13.428 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:13.428 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:13.435 UTC] [V] OCMgr SetMeterValue PhId:0201, branchNo:01, valueId:121005, value:0.000000, scaleFactor:1, devId:7
[2026-08-08 20:29:13.435 UTC] [V] 485DevCtl <C2:01> [01][101100][0.000000][1][V]
[2026-08-08 20:29:13.438 UTC] [V] SummDat SetVrmValue dev_id:7 val:0.000000 sc:3
[2026-08-08 20:29:13.442 UTC] [V] OCMgr SetMeterValue PhId:0201, branchNo:01, valueId:101100, value:0.000000, scaleFactor:1, devId:7
[2026-08-08 20:29:13.448 UTC] [V] 485DevCtl <C2:01> [01][101101][0.000000][1][A]
[2026-08-08 20:29:13.450 UTC] [V] SummDat SetVrmValue dev_id:7 val:0.000000 sc:3
[2026-08-08 20:29:13.454 UTC] [V] OCMgr SetMeterValue PhId:0201, branchNo:01, valueId:101101, value:0.000000, scaleFactor:1, devId:7
[2026-08-08 20:29:13.454 UTC] [V] 485DevCtl <C2:01> [02][101100][0.000000][1][V]
[2026-08-08 20:29:13.454 UTC] [V] SummDat SetVrmValue dev_id:7 val:0.000000 sc:3
[2026-08-08 20:29:13.455 UTC] [V] OCMgr SetMeterValue PhId:0201, branchNo:02, valueId:101100, value:0.000000, scaleFactor:1, devId:7
[2026-08-08 20:29:13.455 UTC] [V] 485DevCtl <C2:01> [02][101101][0.000000][1][A]
[2026-08-08 20:29:13.455 UTC] [V] SummDat SetVrmValue dev_id:7 val:0.000000 sc:3
[2026-08-08 20:29:13.465 UTC] [V] OCMgr SetMeterValue PhId:0201, branchNo:02, valueId:101101, value:0.000000, scaleFactor:1, devId:7
[2026-08-08 20:29:13.477 UTC] [V] 485DevCtl <C3:01> AnalyzeResponseData proc restart cnt:360472 UPRstat:0
[2026-08-08 20:29:13.480 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-08 20:29:13.480 UTC] [D] 485DevCtl <C3:01> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-08 20:29:13.480 UTC] [D] 485DevCtl <C3:01> ResCnd OperationId [6] IsNormal[1] 
[2026-08-08 20:29:13.480 UTC] [V] 485DevCtl <C3:01> device_type:Battery
[2026-08-08 20:29:13.480 UTC] [V] 485ChCtl <C3> set rt:0
[2026-08-08 20:29:13.482 UTC] [V] 485DevCtl <C2:01> [03][101100][0.000000][1][V]
[2026-08-08 20:29:13.482 UTC] [V] SummDat SetVrmValue dev_id:7 val:0.000000 sc:3
[2026-08-08 20:29:13.482 UTC] [V] OCMgr SetMeterValue PhId:0201, branchNo:03, valueId:101100, value:0.000000, scaleFactor:1, devId:7
[2026-08-08 20:29:13.482 UTC] [V] 485DevCtl <C2:01> [03][101101][0.000000][1][A]
[2026-08-08 20:29:13.483 UTC] [V] SummDat SetVrmValue dev_id:7 val:0.000000 sc:3
[2026-08-08 20:29:13.483 UTC] [V] OCMgr SetMeterValue PhId:0201, branchNo:03, valueId:101101, value:0.000000, scaleFactor:1, devId:7
[2026-08-08 20:29:13.483 UTC] [V] 485DevCtl <C2:01> [01][101102][0.000000][0][W]
[2026-08-08 20:29:13.483 UTC] [V] SummDat SetVrmValue dev_id:7 val:0.000000 sc:3
[2026-08-08 20:29:13.483 UTC] [V] OCMgr SetMeterValue PhId:0201, branchNo:01, valueId:101102, value:0.000000, scaleFactor:0, devId:7
[2026-08-08 20:29:13.484 UTC] [V] 485DevCtl <C2:01> [01][111200][0.000000][1][V]
[2026-08-08 20:29:13.484 UTC] [V] SummDat SetVrmValue dev_id:7 val:0.000000 sc:3
[2026-08-08 20:29:13.496 UTC] [V] OCMgr SetMeterValue PhId:0201, branchNo:01, valueId:111200, value:0.000000, scaleFactor:1, devId:7
[2026-08-08 20:29:13.501 UTC] [V] 485DevCtl <C2:01> [02][111200][0.000000][1][V]
[2026-08-08 20:29:13.505 UTC] [V] SummDat SetVrmValue dev_id:7 val:0.000000 sc:3
[2026-08-08 20:29:13.510 UTC] [V] OCMgr SetMeterValue PhId:0201, branchNo:02, valueId:111200, value:0.000000, scaleFactor:1, devId:7
[2026-08-08 20:29:13.514 UTC] [V] 485DevCtl <C2:01> [03][111200][0.000000][1][V]
[2026-08-08 20:29:13.518 UTC] [V] SummDat SetVrmValue dev_id:7 val:0.000000 sc:3
[2026-08-08 20:29:13.519 UTC] [V] OCMgr SetMeterValue PhId:0201, branchNo:03, valueId:111200, value:0.000000, scaleFactor:1, devId:7
[2026-08-08 20:29:13.522 UTC] [V] 485DevCtl <C2:01> [01][111201][0.000000][1][A]
[2026-08-08 20:29:13.526 UTC] [V] SummDat SetVrmValue dev_id:7 val:0.000000 sc:3
[2026-08-08 20:29:13.527 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:13.528 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:13.532 UTC] [V] OCMgr SetMeterValue PhId:0201, branchNo:01, valueId:111201, value:0.000000, scaleFactor:1, devId:7
[2026-08-08 20:29:13.532 UTC] [V] 485DevCtl <C2:01> [02][111201][0.000000][1][A]
[2026-08-08 20:29:13.532 UTC] [V] SummDat SetVrmValue dev_id:7 val:0.000000 sc:3
[2026-08-08 20:29:13.532 UTC] [V] OCMgr SetMeterValue PhId:0201, branchNo:02, valueId:111201, value:0.000000, scaleFactor:1, devId:7
[2026-08-08 20:29:13.540 UTC] [V] 485DevCtl <C2:01> [03][111201][0.000000][1][A]
[2026-08-08 20:29:13.543 UTC] [V] SummDat SetVrmValue dev_id:7 val:0.000000 sc:3
[2026-08-08 20:29:13.555 UTC] [V] OCMgr SetMeterValue PhId:0201, branchNo:03, valueId:111201, value:0.000000, scaleFactor:1, devId:7
[2026-08-08 20:29:13.555 UTC] [V] 485DevCtl <C2:01> [01][111202][0.000000][0][W]
[2026-08-08 20:29:13.559 UTC] [V] SummDat SetVrmValue dev_id:7 val:0.000000 sc:3
[2026-08-08 20:29:13.563 UTC] [V] OCMgr SetMeterValue PhId:0201, branchNo:01, valueId:111202, value:0.000000, scaleFactor:0, devId:7
[2026-08-08 20:29:13.567 UTC] [V] 485DevCtl <C2:01> [01][111203][0.000000][0][var]
[2026-08-08 20:29:13.575 UTC] [V] SummDat SetVrmValue dev_id:7 val:0.000000 sc:3
[2026-08-08 20:29:13.575 UTC] [V] OCMgr SetMeterValue PhId:0201, branchNo:01, valueId:111203, value:0.000000, scaleFactor:0, devId:7
[2026-08-08 20:29:13.576 UTC] [V] 485DevCtl <C2:01> [01][121007][0.000000][3][]
[2026-08-08 20:29:13.576 UTC] [V] SummDat SetVrmValue dev_id:7 val:0.000000 sc:3
[2026-08-08 20:29:13.576 UTC] [V] OCMgr SetMeterValue PhId:0201, branchNo:01, valueId:121007, value:0.000000, scaleFactor:3, devId:7
[2026-08-08 20:29:13.576 UTC] [V] 485DevCtl <C2:01> [01][131006][0.000000][1][Hz]
[2026-08-08 20:29:13.576 UTC] [V] SummDat SetVrmValue dev_id:7 val:0.000000 sc:3
[2026-08-08 20:29:13.577 UTC] [V] OCMgr SetMeterValue PhId:0201, branchNo:01, valueId:131006, value:0.000000, scaleFactor:1, devId:7
[2026-08-08 20:29:13.577 UTC] [V] 485DevCtl <C2:01> [01][114202][64704.000000][0][kWh]
[2026-08-08 20:29:13.587 UTC] [V] SummDat SetVrmValue dev_id:7 val:64704000.000000 sc:3
[2026-08-08 20:29:13.589 UTC] [V] OCMgr SetMeterValue PhId:0201, branchNo:01, valueId:114202, value:64704.000000, scaleFactor:0, devId:7
[2026-08-08 20:29:13.592 UTC] [V] 485DevCtl <C2:01> device_type:PV-PCS
[2026-08-08 20:29:13.598 UTC] [V] 485DevCtl <C2:01> set2 StatusCode[010100] DeviceName[] DeviceNumber[]
[2026-08-08 20:29:13.599 UTC] [V] 485ChCtl <C2> set rt:0
[2026-08-08 20:29:13.609 UTC] [V] 485ChCtl <C2> StartDeviceCommunicationForOutputFluctuationSuppressionControlBroadcast 4 cnt:3604782, monitor_cnt:56, bc_elapsed:3604782, min:10, max:40
[2026-08-08 20:29:13.610 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :9
[2026-08-08 20:29:13.610 UTC] [V] 485ChCtl <C2> send request:Sungrow08
[2026-08-08 20:29:13.613 UTC] [D] 485AcReq <C2:02> PutOStream [9][0800020413fa00179482]
[2026-08-08 20:29:13.627 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:13.627 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:13.679 UTC] [V] OFSCtrl [/var/local/solajithome/function/output_fluctuation_suppression/batt_data] write success.
[2026-08-08 20:29:13.727 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:13.727 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:13.828 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:13.828 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:13.928 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:13.928 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:13.984 UTC] [V] Res no response condition. set normal condition.
[2026-08-08 20:29:13.986 UTC] [D] 485DevCtl <C2:02> RcvDat status[2] len[51] [02042e000000000000000000000000ffffffffffffffff03e8ffffffff420e0000ffffffffffffffffffffffffffffffff914e]
[2026-08-08 20:29:13.986 UTC] [D] 485DevCtl <C2:02> ResCnd OperationId [9] IsNormal[1] 
[2026-08-08 20:29:13.987 UTC] [V] 485DevCtl <C2:02> [04][101100][0.000000][1][V]
[2026-08-08 20:29:13.987 UTC] [V] SummDat SetVrmValue dev_id:8 val:0.000000 sc:3
[2026-08-08 20:29:13.991 UTC] [V] OCMgr SetMeterValue PhId:0202, branchNo:04, valueId:101100, value:0.000000, scaleFactor:1, devId:8
[2026-08-08 20:29:13.992 UTC] [V] 485DevCtl <C2:02> [04][101101][0.000000][1][A]
[2026-08-08 20:29:13.992 UTC] [V] SummDat SetVrmValue dev_id:8 val:0.000000 sc:3
[2026-08-08 20:29:13.992 UTC] [V] OCMgr SetMeterValue PhId:0202, branchNo:04, valueId:101101, value:0.000000, scaleFactor:1, devId:8
[2026-08-08 20:29:13.992 UTC] [V] 485DevCtl <C2:02> [05][101100][0.000000][1][V]
[2026-08-08 20:29:14.000 UTC] [V] SummDat SetVrmValue dev_id:8 val:0.000000 sc:3
[2026-08-08 20:29:14.003 UTC] [V] OCMgr SetMeterValue PhId:0202, branchNo:05, valueId:101100, value:0.000000, scaleFactor:1, devId:8
[2026-08-08 20:29:14.006 UTC] [V] 485DevCtl <C2:02> [05][101101][0.000000][1][A]
[2026-08-08 20:29:14.010 UTC] [V] SummDat SetVrmValue dev_id:8 val:0.000000 sc:3
[2026-08-08 20:29:14.021 UTC] [V] OCMgr SetMeterValue PhId:0202, branchNo:05, valueId:101101, value:0.000000, scaleFactor:1, devId:8
[2026-08-08 20:29:14.022 UTC] [V] 485DevCtl <C2:02> [06][101100][0.000000][1][V]
[2026-08-08 20:29:14.023 UTC] [V] SummDat SetVrmValue dev_id:8 val:0.000000 sc:3
[2026-08-08 20:29:14.026 UTC] [V] OCMgr SetMeterValue PhId:0202, branchNo:06, valueId:101100, value:0.000000, scaleFactor:1, devId:8
[2026-08-08 20:29:14.028 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:14.028 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:14.032 UTC] [V] 485DevCtl <C2:02> [06][101101][0.000000][1][A]
[2026-08-08 20:29:14.034 UTC] [V] SummDat SetVrmValue dev_id:8 val:0.000000 sc:3
[2026-08-08 20:29:14.034 UTC] [V] OCMgr SetMeterValue PhId:0202, branchNo:06, valueId:101101, value:0.000000, scaleFactor:1, devId:8
[2026-08-08 20:29:14.035 UTC] [V] 485DevCtl <C2:02> device_type:PV-PCS
[2026-08-08 20:29:14.052 UTC] [V] 485ChCtl <C2> set rt:0
[2026-08-08 20:29:14.053 UTC] [D] 485ChCtl <C2> monitoring dev All Send
[2026-08-08 20:29:14.127 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:14.128 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:14.227 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:14.227 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:14.327 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:14.327 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:14.327 UTC] [V] OFSCtrl Control charge discharge proc start.
[2026-08-08 20:29:14.328 UTC] [V] OFSCtrl CHG 20 p_th(t):-1109.900000 = p_th_old_:-1100.000000 + lev_cd_:-0.300000 * (total_pcs_capacity_:99000.000000 * cof_spec_:2.000000 / 60 * (time_threshold_renew:10.000000 * 10)), min:-1100.000000, max:119300.000000
[2026-08-08 20:29:14.328 UTC] [V] OFSCtrl CHG 21 batt_w:330.369526 = old:333.807026 +  kp:0.550000 * e:-6.250000 + ki:0.000000 * sume:9163193.200228 + kd:0.040000 * (e:-6.250000 - e1:-6.250000)
[2026-08-08 20:29:14.328 UTC] [V] OFSCtrl CHG 29 q:3.000000, mod(round):0.000000
[2026-08-08 20:29:14.329 UTC] [D] OFSCtrl battery ctrl val:0.700000
[2026-08-08 20:29:14.329 UTC] [V] 485ChCtl <C3> battery limit on [3.000000,] request.
[2026-08-08 20:29:14.329 UTC] [V] OFSCtrl Control charge discharge proc:01->02->BATT_CHK->03->04->05->06->07->10->11->20->21->22->23->24->25->27->28->29->30->31->32->33->34
[2026-08-08 20:29:14.329 UTC] [V] 485ChCtl <C3> battery send request.1
[2026-08-08 20:29:14.330 UTC] [D] VarInf Limit_Bat rt[2]set val[3] set rate[0.600000] value100[500] value-100[-500]
[2026-08-08 20:29:14.331 UTC] [D] 485AcReq <C3:01> PutOStream [6][0f000001000000090110278e0001020003]
[2026-08-08 20:29:14.428 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:14.428 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:14.488 UTC] [V] 485DevCtl <C3:01> AnalyzeResponseData proc restart cnt:360473 UPRstat:0
[2026-08-08 20:29:14.489 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-08 20:29:14.489 UTC] [D] 485DevCtl <C3:01> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-08 20:29:14.489 UTC] [D] 485DevCtl <C3:01> ResCnd OperationId [6] IsNormal[1] 
[2026-08-08 20:29:14.489 UTC] [V] 485DevCtl <C3:01> device_type:Battery
[2026-08-08 20:29:14.490 UTC] [V] 485ChCtl <C3> set rt:0
[2026-08-08 20:29:14.527 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:14.528 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:14.627 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:14.628 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:14.679 UTC] [V] OFSCtrl [/var/local/solajithome/function/output_fluctuation_suppression/batt_data] write success.
[2026-08-08 20:29:14.727 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:14.727 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:14.828 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:14.828 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:14.928 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:14.928 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:15.028 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:15.028 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:15.127 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:15.128 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:15.227 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:15.228 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:15.327 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:15.328 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:15.328 UTC] [V] OFSCtrl Control charge discharge proc start.
[2026-08-08 20:29:15.328 UTC] [V] OFSCtrl CHG 20 p_th(t):-1109.900000 = p_th_old_:-1100.000000 + lev_cd_:-0.300000 * (total_pcs_capacity_:99000.000000 * cof_spec_:2.000000 / 60 * (time_threshold_renew:10.000000 * 10)), min:-1100.000000, max:119300.000000
[2026-08-08 20:29:15.328 UTC] [V] OFSCtrl CHG 21 batt_w:326.932026 = old:330.369526 +  kp:0.550000 * e:-6.250000 + ki:0.000000 * sume:9163186.950228 + kd:0.040000 * (e:-6.250000 - e1:-6.250000)
[2026-08-08 20:29:15.329 UTC] [V] OFSCtrl CHG 29 q:3.000000, mod(round):0.000000
[2026-08-08 20:29:15.329 UTC] [D] OFSCtrl battery ctrl val:0.700000
[2026-08-08 20:29:15.329 UTC] [V] 485ChCtl <C3> battery limit on [3.000000,] request.
[2026-08-08 20:29:15.329 UTC] [V] OFSCtrl Control charge discharge proc:01->02->BATT_CHK->03->04->05->06->07->10->11->20->21->22->23->24->25->27->28->29->30->31->32->33->34
[2026-08-08 20:29:15.330 UTC] [V] 485ChCtl <C3> battery send request.1
[2026-08-08 20:29:15.330 UTC] [D] VarInf Limit_Bat rt[2]set val[3] set rate[0.600000] value100[500] value-100[-500]
[2026-08-08 20:29:15.332 UTC] [D] 485AcReq <C3:01> PutOStream [6][0f000001000000090110278e0001020003]
[2026-08-08 20:29:15.375 UTC] [V] OC485DevMgr TargetPowerPolling 
[2026-08-08 20:29:15.376 UTC] [V] OC485DevMgr TargetPowerPolling Target power no ud current[20260808200000]now[20260808202915]next[20260808203000]
[2026-08-08 20:29:15.376 UTC] [V] OCMgr UpdateExtCurrentTarget call
[2026-08-08 20:29:15.376 UTC] [V] OCMgr UpdateExtSchedule call
[2026-08-08 20:29:15.376 UTC] [V] OCMgr UpdateExtSchedule file none. ext rate:-1, time:20200101000000
[2026-08-08 20:29:15.377 UTC] [V] OCMgr IsPvocdScheduleError 0
[2026-08-08 20:29:15.377 UTC] [V] OCMgr UpdateExtCurrentTarget check schedule:0, ext rate:-1
[2026-08-08 20:29:15.377 UTC] [V] OCMgr CalcOutputControlPower pow:99.000000, rate:100, cap:99.000000
[2026-08-08 20:29:15.377 UTC] [V] OCMgr IsPvocdScheduleError 0
[2026-08-08 20:29:15.378 UTC] [D] OCMgr UpdateExtCurrentTarget external none, in_pow:99.000000, 99.000000
[2026-08-08 20:29:15.379 UTC] [V] OCMgr CalcOutputControlRate rate:100, pow:99.000000, cap:99.000000, rate_out:99.000000
[2026-08-08 20:29:15.381 UTC] [V] OCMgr WriteExtSchedule dat:100,20260809053000
[2026-08-08 20:29:15.384 UTC] [V] FlUtil write csv file[/media/sdcard/solajithome/Log/modbus/ExecSchedulePath/ExecEmsSchedule.csv] result:1
[2026-08-08 20:29:15.384 UTC] [V] OCMgr now time:20260808200000, power_value:99.000000, rt:0
[2026-08-08 20:29:15.393 UTC] [V] 485DevCtl <C1:01> device_type:Irr-Meter
[2026-08-08 20:29:15.393 UTC] [V] 485DevCtl <C1:01> device_type:Irr-Meter
[2026-08-08 20:29:15.393 UTC] [V] 485ChCtl <C1> fixed cycle Irr-Meter
[2026-08-08 20:29:15.393 UTC] [V] 485DevCtl <C1:01> Dev not PCS IsNeedToChangeOControlState
[2026-08-08 20:29:15.393 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :1
[2026-08-08 20:29:15.394 UTC] [V] 485ChCtl <C1> send request:Irr01
[2026-08-08 20:29:15.395 UTC] [D] 485AcReq <C1:01> PutOStream [1][080001040000000271cb]
[2026-08-08 20:29:15.407 UTC] [V] OCMgr next time:20260808203000, power_value:99.000000, rt:0
[2026-08-08 20:29:15.414 UTC] [V] OCMgr GetCurrentTargetPower current target:99.000000
[2026-08-08 20:29:15.415 UTC] [V] OCMgr CalcOutputControlRate rate:100, pow:99.000000, cap:99.000000, rate_out:99.000000
[2026-08-08 20:29:15.415 UTC] [V] OCMgr IsPvocdCommunication 1
[2026-08-08 20:29:15.426 UTC] [V] OCMgr IsPvocdScheduleError 0
[2026-08-08 20:29:15.427 UTC] [V] OCMgr UpdateActiveMode mode:OFS conditions:output rate 100.
[2026-08-08 20:29:15.428 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:15.428 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:15.428 UTC] [V] LgMgr change mode OFS -> OFS
[2026-08-08 20:29:15.487 UTC] [V] 485DevCtl <C3:01> AnalyzeResponseData proc restart cnt:360474 UPRstat:0
[2026-08-08 20:29:15.490 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-08 20:29:15.491 UTC] [D] 485DevCtl <C3:01> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-08 20:29:15.491 UTC] [D] 485DevCtl <C3:01> ResCnd OperationId [6] IsNormal[1] 
[2026-08-08 20:29:15.491 UTC] [V] 485DevCtl <C3:01> device_type:Battery
[2026-08-08 20:29:15.491 UTC] [V] 485ChCtl <C3> set rt:0
[2026-08-08 20:29:15.528 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:15.528 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:15.541 UTC] [I] Wdog command:/usr/bin/touch "/mnt/system/check/pvsl"
[2026-08-08 20:29:15.628 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:15.628 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:15.679 UTC] [V] OFSCtrl [/var/local/solajithome/function/output_fluctuation_suppression/batt_data] write success.
[2026-08-08 20:29:15.728 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:15.728 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:15.729 UTC] [V] 485ChCtl <C3> StartDeviceCommunicationForOutputFluctuationSuppressionControlBroadcast 4 cnt:3604803, monitor_cnt:50, bc_elapsed:3604803, min:10, max:40
[2026-08-08 20:29:15.729 UTC] [V] OFSCtrl /var/local/solajithome/function/output_fluctuation_suppression/state is exist:0
[2026-08-08 20:29:15.730 UTC] [V] 485DevCtl <C3:01> Dev not PCS IsNeedToChangeOControlState
[2026-08-08 20:29:15.730 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :12
[2026-08-08 20:29:15.731 UTC] [V] 485ChCtl <C3> send request:Sungrow11
[2026-08-08 20:29:15.732 UTC] [D] 485AcReq <C3:01> PutOStream [12][0c00000100000006010427580001]
[2026-08-08 20:29:15.738 UTC] [V] 485DevCtl <C1:01> AnalyzeResponseData proc restart cnt:360476 UPRstat:0
[2026-08-08 20:29:15.738 UTC] [V] Res no response condition. set normal condition.
[2026-08-08 20:29:15.738 UTC] [D] 485DevCtl <C1:01> RcvDat status[2] len[9] [010404000002013b24]
[2026-08-08 20:29:15.739 UTC] [D] 485DevCtl <C1:01> ResCnd OperationId [1] IsNormal[1] 
[2026-08-08 20:29:15.739 UTC] [V] OFSCtrl Rcv set flux_of_solar:0.000000
[2026-08-08 20:29:15.739 UTC] [V] 485DevCtl <C1:01> [01][401006][0.000000][1][W/m2]
[2026-08-08 20:29:15.739 UTC] [V] SummDat SetVrmValue dev_id:1 val:0.000000 sc:3
[2026-08-08 20:29:15.740 UTC] [V] OCMgr SetMeterValue PhId:0101, branchNo:01, valueId:401006, value:0.000000, scaleFactor:1, devId:1
[2026-08-08 20:29:15.740 UTC] [V] 485DevCtl <C1:01> [01][421005][263.000000][1][℃]
[2026-08-08 20:29:15.740 UTC] [V] SummDat SetVrmValue dev_id:1 val:26300.000000 sc:3
[2026-08-08 20:29:15.741 UTC] [V] OCMgr SetMeterValue PhId:0101, branchNo:01, valueId:421005, value:263.000000, scaleFactor:1, devId:1
[2026-08-08 20:29:15.741 UTC] [V] 485DevCtl <C1:01> device_type:Irr-Meter
[2026-08-08 20:29:15.742 UTC] [V] OFSCtrl Irr-Meter received.
[2026-08-08 20:29:15.765 UTC] [V] 485ChCtl <C1> set rt:0
[2026-08-08 20:29:15.765 UTC] [V] 485DevCtl <C1:01> device_type:Irr-Meter
[2026-08-08 20:29:15.793 UTC] [V] 485DevCtl <C1:04> device_type:CO-Meter
[2026-08-08 20:29:15.793 UTC] [V] 485DevCtl <C1:04> device_type:CO-Meter
[2026-08-08 20:29:15.793 UTC] [V] 485ChCtl <C1> fixed cycle CO-Meter
[2026-08-08 20:29:15.793 UTC] [V] 485DevCtl <C1:04> Dev not PCS IsNeedToChangeOControlState
[2026-08-08 20:29:15.793 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :1
[2026-08-08 20:29:15.794 UTC] [V] 485ChCtl <C1> send request:omron05
[2026-08-08 20:29:15.796 UTC] [D] 485AcReq <C1:04> PutOStream [1][0800040300030014b590]
[2026-08-08 20:29:15.828 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:15.828 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:15.879 UTC] [V] 485DevCtl <C3:01> AnalyzeResponseData proc restart cnt:360475 UPRstat:0
[2026-08-08 20:29:15.879 UTC] [D] 485DevCtl <C3:01> RcvDat status[0] len[11] [0001000000050104020010]
[2026-08-08 20:29:15.879 UTC] [D] 485DevCtl <C3:01> ResCnd OperationId [12] IsNormal[1]  ConditionType [lggrdev:Normal] Action[-1]
[2026-08-08 20:29:15.880 UTC] [V] 485DevCtl <C3:01> [02][753040][1.000000][0][]
[2026-08-08 20:29:15.880 UTC] [V] SummDat SetVrmValue dev_id:9 val:1.000000 sc:0
[2026-08-08 20:29:15.880 UTC] [V] OCMgr SetMeterValue PhId:0301, branchNo:02, valueId:753040, value:1.000000, scaleFactor:0, devId:9
[2026-08-08 20:29:15.881 UTC] [V] 485DevCtl <C3:01> device_type:Battery
[2026-08-08 20:29:15.882 UTC] [V] 485ChCtl <C3> set rt:0
[2026-08-08 20:29:15.889 UTC] [D] 485ChCtl <C3> monitoring dev All Send
[2026-08-08 20:29:15.929 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:15.929 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:16.027 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:16.028 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:16.127 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:16.128 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:16.200 UTC] [V] 485DevCtl <C1:04> AnalyzeResponseData proc restart cnt:360475 UPRstat:0
[2026-08-08 20:29:16.200 UTC] [V] Res no response condition. set normal condition.
[2026-08-08 20:29:16.201 UTC] [D] 485DevCtl <C1:04> RcvDat status[2] len[45] [0403280000221b000017f0000017ebffffffe400000256ffffe886ffffffc4ffffaf84ffffff3200121a818ea0]
[2026-08-08 20:29:16.201 UTC] [D] 485DevCtl <C1:04> ResCnd OperationId [1] IsNormal[1] 
[2026-08-08 20:29:16.203 UTC] [V] OFSCtrl Rcv set p_co:-600.000000, p_co_old:-600.000000
[2026-08-08 20:29:16.203 UTC] [V] 485DevCtl <C1:04> [01][601260][-60.000000][2][kW]
[2026-08-08 20:29:16.203 UTC] [V] SummDat SetVrmValue dev_id:4 val:-600.000000 sc:3
[2026-08-08 20:29:16.204 UTC] [V] OCMgr SetMeterValue PhId:0104, branchNo:01, valueId:601260, value:-60.000000, scaleFactor:2, devId:4
[2026-08-08 20:29:16.204 UTC] [V] 485DevCtl <C1:04> [01][603260][1186433.000000][1][kWh]
[2026-08-08 20:29:16.204 UTC] [V] SummDat SetVrmValue dev_id:4 val:1186433.000000 sc:1
[2026-08-08 20:29:16.204 UTC] [V] OCMgr SetMeterValue PhId:0104, branchNo:01, valueId:603260, value:1186433.000000, scaleFactor:1, devId:4
[2026-08-08 20:29:16.218 UTC] [V] 485DevCtl <C1:04> device_type:CO-Meter
[2026-08-08 20:29:16.218 UTC] [V] OFSCtrl km50 received.
[2026-08-08 20:29:16.219 UTC] [V] OFSCtrl omron05_local_date :2026/08/09 ? 2026/08/09
[2026-08-08 20:29:16.219 UTC] [V] OFSCtrl omron05_local_time :2026/08/09 05 ? 2026/08/09 05
[2026-08-08 20:29:16.227 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:16.228 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:16.233 UTC] [V] OFSCtrl out of control time.
[2026-08-08 20:29:16.235 UTC] [V] OFSCtrl Control pv-pcs proc start.
[2026-08-08 20:29:16.245 UTC] [V] OFSCtrl NOD_month:-1664.000000 = (NOD_month:306 - ((nod_max_/30):23.333333 * (cnt-1):25) * (30/cnt):6.000000 
[2026-08-08 20:29:16.245 UTC] [V] OFSCtrl PCS ratio_month:232.646617 = -k_inhibition_ratio_month:-0.097744 * NOD_month:-1664.000000 + inhibition_ratio_max:70
[2026-08-08 20:29:16.253 UTC] [V] OFSCtrl PCS 05 inhibition_ratio:70.000000 = max(ratio_min:5, min(ratio:70, ratio_hour:70.000000, ratio_day:70.000000, ratio_month:232.646617))
[2026-08-08 20:29:16.261 UTC] [D] OFSCtrl pv-pcs ctrl val:0.000000 old:0.000000
[2026-08-08 20:29:16.262 UTC] [V] OCHisDB set rate:0 t_rate:0 cnt:50
[2026-08-08 20:29:16.267 UTC] [V] 485ChCtl <C2> pv-pcs limit on [0.000000] request.
[2026-08-08 20:29:16.268 UTC] [V] OFSCtrl Control pv-pcs proc:BATT_CHK->01->02->03->04->05->06->07->09->09->10->11->12
[2026-08-08 20:29:16.274 UTC] [V] 485ChCtl <C1> set rt:0
[2026-08-08 20:29:16.275 UTC] [V] 485DevCtl <C1:04> device_type:CO-Meter
[2026-08-08 20:29:16.310 UTC] [V] 485ChCtl <C2> pv-pcs send request.
[2026-08-08 20:29:16.311 UTC] [D] VarInf update ofs_rate:0.000000
[2026-08-08 20:29:16.311 UTC] [V] VarInf LimitSet rt[2] val[170] key[ValueOn]
[2026-08-08 20:29:16.311 UTC] [D] VarInf output_mode:8
[2026-08-08 20:29:16.311 UTC] [D] VarInf update ofs_rate:0.000000
[2026-08-08 20:29:16.311 UTC] [D] VarInf Limit setRate[0.000000] rate[0.000000] value100[1000.000000] value0[0.000000]
[2026-08-08 20:29:16.311 UTC] [V] 485DevCtl <C2:01> ChangeOutputRateToDevice rate:0.000000 set_rate1
[2026-08-08 20:29:16.311 UTC] [D] VarInf Limit rt[2] int_set_rate[1] server_rate[0.000000] rated_output[100.000000] solar_battery_power[100.000000]
[2026-08-08 20:29:16.313 UTC] [D] 485AcReq <C2:01> PutOStreamForBc [3][0d000010138e00020400aa0001466f]
[2026-08-08 20:29:16.327 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:16.328 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:16.328 UTC] [V] OFSCtrl Control charge discharge proc start.
[2026-08-08 20:29:16.328 UTC] [V] OFSCtrl CHG 20 p_th(t):-1109.900000 = p_th_old_:-1100.000000 + lev_cd_:-0.300000 * (total_pcs_capacity_:99000.000000 * cof_spec_:2.000000 / 60 * (time_threshold_renew:10.000000 * 10)), min:-1100.000000, max:119300.000000
[2026-08-08 20:29:16.329 UTC] [V] OFSCtrl CHG 21 batt_w:323.494526 = old:326.932026 +  kp:0.550000 * e:-6.250000 + ki:0.000000 * sume:9163180.700228 + kd:0.040000 * (e:-6.250000 - e1:-6.250000)
[2026-08-08 20:29:16.329 UTC] [V] OFSCtrl CHG 29 q:3.000000, mod(round):0.000000
[2026-08-08 20:29:16.329 UTC] [D] OFSCtrl battery ctrl val:0.600000
[2026-08-08 20:29:16.329 UTC] [V] 485ChCtl <C3> battery limit on [3.000000,] request.
[2026-08-08 20:29:16.329 UTC] [V] OFSCtrl Control charge discharge proc:01->02->BATT_CHK->03->04->05->06->07->10->11->20->21->22->23->24->25->27->28->29->30->31->32->33->34
[2026-08-08 20:29:16.330 UTC] [V] 485ChCtl <C3> battery send request.1
[2026-08-08 20:29:16.330 UTC] [D] VarInf Limit_Bat rt[2]set val[3] set rate[0.600000] value100[500] value-100[-500]
[2026-08-08 20:29:16.332 UTC] [D] 485AcReq <C3:01> PutOStream [6][0f000001000000090110278e0001020003]
[2026-08-08 20:29:16.428 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:16.428 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:16.487 UTC] [V] 485DevCtl <C3:01> AnalyzeResponseData proc restart cnt:360475 UPRstat:0
[2026-08-08 20:29:16.489 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-08 20:29:16.489 UTC] [D] 485DevCtl <C3:01> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-08 20:29:16.489 UTC] [D] 485DevCtl <C3:01> ResCnd OperationId [6] IsNormal[1] 
[2026-08-08 20:29:16.489 UTC] [V] 485DevCtl <C3:01> device_type:Battery
[2026-08-08 20:29:16.490 UTC] [V] 485ChCtl <C3> set rt:0
[2026-08-08 20:29:16.528 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:16.528 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:16.607 UTC] [V] 485ChCtl <C2> set rt:0
[2026-08-08 20:29:16.628 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:16.628 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:16.679 UTC] [V] OFSCtrl [/var/local/solajithome/function/output_fluctuation_suppression/batt_data] write success.
[2026-08-08 20:29:16.728 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:16.728 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:16.828 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:16.828 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:16.928 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:16.928 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:17.028 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:17.028 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:17.128 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:17.128 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:17.228 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:17.228 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:17.328 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:17.328 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:17.328 UTC] [V] OFSCtrl Control charge discharge proc start.
[2026-08-08 20:29:17.328 UTC] [V] OFSCtrl CHG 20 p_th(t):-1109.900000 = p_th_old_:-1100.000000 + lev_cd_:-0.300000 * (total_pcs_capacity_:99000.000000 * cof_spec_:2.000000 / 60 * (time_threshold_renew:10.000000 * 10)), min:-1100.000000, max:119300.000000
[2026-08-08 20:29:17.329 UTC] [V] OFSCtrl CHG 21 batt_w:320.057026 = old:323.494526 +  kp:0.550000 * e:-6.250000 + ki:0.000000 * sume:9163174.450228 + kd:0.040000 * (e:-6.250000 - e1:-6.250000)
[2026-08-08 20:29:17.329 UTC] [V] OFSCtrl CHG 29 q:3.000000, mod(round):0.000000
[2026-08-08 20:29:17.329 UTC] [D] OFSCtrl battery ctrl val:0.600000
[2026-08-08 20:29:17.329 UTC] [V] 485ChCtl <C3> battery limit on [3.000000,] request.
[2026-08-08 20:29:17.330 UTC] [V] OFSCtrl Control charge discharge proc:01->02->BATT_CHK->03->04->05->06->07->10->11->20->21->22->23->24->25->27->28->29->30->31->32->33->34
[2026-08-08 20:29:17.330 UTC] [V] 485ChCtl <C3> battery send request.1
[2026-08-08 20:29:17.330 UTC] [D] VarInf Limit_Bat rt[2]set val[3] set rate[0.600000] value100[500] value-100[-500]
[2026-08-08 20:29:17.332 UTC] [D] 485AcReq <C3:01> PutOStream [6][0f000001000000090110278e0001020003]
[2026-08-08 20:29:17.427 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:17.428 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:17.487 UTC] [V] 485DevCtl <C3:01> AnalyzeResponseData proc restart cnt:360476 UPRstat:0
[2026-08-08 20:29:17.489 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-08 20:29:17.490 UTC] [D] 485DevCtl <C3:01> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-08 20:29:17.490 UTC] [D] 485DevCtl <C3:01> ResCnd OperationId [6] IsNormal[1] 
[2026-08-08 20:29:17.490 UTC] [V] 485DevCtl <C3:01> device_type:Battery
[2026-08-08 20:29:17.491 UTC] [V] 485ChCtl <C3> set rt:0
[2026-08-08 20:29:17.527 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:17.528 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:17.627 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:17.628 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:17.679 UTC] [V] OFSCtrl [/var/local/solajithome/function/output_fluctuation_suppression/batt_data] write success.
[2026-08-08 20:29:17.727 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:17.727 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:17.827 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:17.828 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:17.927 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:17.928 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:18.027 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:18.028 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:18.093 UTC] [V] 485ChCtl <C1> StartDeviceCommunicationForOutputFluctuationSuppressionControlBroadcast 4 cnt:3604827, monitor_cnt:100, bc_elapsed:27, min:10, max:40
[2026-08-08 20:29:18.093 UTC] [V] OFSCtrl /var/local/solajithome/function/output_fluctuation_suppression/state is exist:0
[2026-08-08 20:29:18.127 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:18.127 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:18.193 UTC] [V] 485ChCtl <C1> StartDeviceCommunicationForOutputFluctuationSuppressionControlBroadcast 4 cnt:3604828, monitor_cnt:101, bc_elapsed:28, min:10, max:40
[2026-08-08 20:29:18.193 UTC] [V] 485DevCtl <C1:02> Dev not PCS IsNeedToChangeOControlState
[2026-08-08 20:29:18.193 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :1
[2026-08-08 20:29:18.194 UTC] [V] 485ChCtl <C1> send request:IMT01
[2026-08-08 20:29:18.195 UTC] [D] 485AcReq <C1:02> PutOStream [1][08000204000200019039]
[2026-08-08 20:29:18.227 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:18.227 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:18.327 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:18.327 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:18.327 UTC] [V] OFSCtrl Control charge discharge proc start.
[2026-08-08 20:29:18.328 UTC] [V] OFSCtrl CHG 20 p_th(t):-1109.900000 = p_th_old_:-1100.000000 + lev_cd_:-0.300000 * (total_pcs_capacity_:99000.000000 * cof_spec_:2.000000 / 60 * (time_threshold_renew:10.000000 * 10)), min:-1100.000000, max:119300.000000
[2026-08-08 20:29:18.329 UTC] [V] OFSCtrl CHG 21 batt_w:316.619526 = old:320.057026 +  kp:0.550000 * e:-6.250000 + ki:0.000000 * sume:9163168.200228 + kd:0.040000 * (e:-6.250000 - e1:-6.250000)
[2026-08-08 20:29:18.329 UTC] [V] OFSCtrl CHG 29 q:3.000000, mod(round):0.000000
[2026-08-08 20:29:18.329 UTC] [D] OFSCtrl battery ctrl val:0.600000
[2026-08-08 20:29:18.330 UTC] [V] 485ChCtl <C3> battery limit on [3.000000,] request.
[2026-08-08 20:29:18.330 UTC] [V] OFSCtrl Control charge discharge proc:01->02->BATT_CHK->03->04->05->06->07->10->11->20->21->22->23->24->25->27->28->29->30->31->32->33->34
[2026-08-08 20:29:18.428 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:18.428 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:18.430 UTC] [V] 485ChCtl <C3> battery send request.1
[2026-08-08 20:29:18.431 UTC] [D] VarInf Limit_Bat rt[2]set val[3] set rate[0.600000] value100[500] value-100[-500]
[2026-08-08 20:29:18.432 UTC] [D] 485AcReq <C3:01> PutOStream [6][0f000001000000090110278e0001020003]
[2026-08-08 20:29:18.528 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:18.528 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:18.531 UTC] [V] 485DevCtl <C1:02> AnalyzeResponseData proc restart cnt:360472 UPRstat:0
[2026-08-08 20:29:18.531 UTC] [V] Res no response condition. set normal condition.
[2026-08-08 20:29:18.531 UTC] [D] 485DevCtl <C1:02> RcvDat status[2] len[7] [02040202067c52]
[2026-08-08 20:29:18.531 UTC] [D] 485DevCtl <C1:02> ResCnd OperationId [1] IsNormal[1] 
[2026-08-08 20:29:18.532 UTC] [V] 485DevCtl <C1:02> [01][431005][268.000000][1][°C]
[2026-08-08 20:29:18.532 UTC] [V] SummDat SetVrmValue dev_id:2 val:26800.000000 sc:3
[2026-08-08 20:29:18.532 UTC] [V] OCMgr SetMeterValue PhId:0102, branchNo:01, valueId:431005, value:268.000000, scaleFactor:1, devId:2
[2026-08-08 20:29:18.533 UTC] [V] 485DevCtl <C1:02> device_type:
[2026-08-08 20:29:18.534 UTC] [V] 485ChCtl <C1> set rt:0
[2026-08-08 20:29:18.577 UTC] [V] 485DevCtl <C3:01> AnalyzeResponseData proc restart cnt:360478 UPRstat:0
[2026-08-08 20:29:18.580 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-08 20:29:18.580 UTC] [D] 485DevCtl <C3:01> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-08 20:29:18.581 UTC] [D] 485DevCtl <C3:01> ResCnd OperationId [6] IsNormal[1] 
[2026-08-08 20:29:18.581 UTC] [V] 485DevCtl <C3:01> device_type:Battery
[2026-08-08 20:29:18.581 UTC] [V] 485ChCtl <C3> set rt:0
[2026-08-08 20:29:18.593 UTC] [V] 485ChCtl <C1> StartDeviceCommunicationForOutputFluctuationSuppressionControlBroadcast 4 cnt:3604832, monitor_cnt:105, bc_elapsed:32, min:10, max:40
[2026-08-08 20:29:18.593 UTC] [V] 485DevCtl <C1:03> Dev not PCS IsNeedToChangeOControlState
[2026-08-08 20:29:18.593 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :1
[2026-08-08 20:29:18.594 UTC] [V] 485ChCtl <C1> send request:omron03
[2026-08-08 20:29:18.595 UTC] [D] 485AcReq <C1:03> PutOStream [1][08000303000000144427]
[2026-08-08 20:29:18.609 UTC] [V] 485ChCtl <C2> StartDeviceCommunicationForOutputFluctuationSuppressionControlBroadcast 4 cnt:3604832, monitor_cnt:50, bc_elapsed:3604832, min:10, max:40
[2026-08-08 20:29:18.610 UTC] [V] OFSCtrl /var/local/solajithome/function/output_fluctuation_suppression/state is exist:0
[2026-08-08 20:29:18.610 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :2
[2026-08-08 20:29:18.610 UTC] [V] 485ChCtl <C2> send request:Sungrow08
[2026-08-08 20:29:18.611 UTC] [D] 485AcReq <C2:01> PutOStream [2][0800010413d80002f574]
[2026-08-08 20:29:18.628 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:18.628 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:18.679 UTC] [V] OFSCtrl [/var/local/solajithome/function/output_fluctuation_suppression/batt_data] write success.
[2026-08-08 20:29:18.728 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:18.728 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:18.828 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:18.828 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:18.928 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:18.928 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:18.941 UTC] [D] 485DevCtl <C2:01> RcvDat status[2] len[9] [01040400100000fa41]
[2026-08-08 20:29:18.941 UTC] [D] 485DevCtl <C2:01> ResCnd OperationId [2] IsNormal[0]  ConditionType [lggrdev:Error] Action[4]
[2026-08-08 20:29:18.943 UTC] [V] 485DevCtl <C2:01> device_type:PV-PCS
[2026-08-08 20:29:18.943 UTC] [V] 485DevCtl <C2:01> ExecuteAction name:RestartCounter value0
[2026-08-08 20:29:18.944 UTC] [V] 485DevCtl <C2:01> ExecuteAction set start cnt:0
[2026-08-08 20:29:18.944 UTC] [V] 485ChCtl <C2> set rt:0
[2026-08-08 20:29:18.988 UTC] [V] 485DevCtl <C1:03> AnalyzeResponseData proc restart cnt:360472 UPRstat:0
[2026-08-08 20:29:18.988 UTC] [V] Res no response condition. set normal condition.
[2026-08-08 20:29:18.989 UTC] [D] 485DevCtl <C1:03> RcvDat status[2] len[45] [0303280000fe170001002d0000ffe4000022f80000274100002e1e0000005f000002570010b93b00002acf0a9d]
[2026-08-08 20:29:18.989 UTC] [D] 485DevCtl <C1:03> ResCnd OperationId [1] IsNormal[1] 
[2026-08-08 20:29:18.990 UTC] [V] 485DevCtl <C1:03> [01][301200][65047.000000][1][V]
[2026-08-08 20:29:18.990 UTC] [V] SummDat SetVrmValue dev_id:3 val:6504700.000000 sc:3
[2026-08-08 20:29:18.996 UTC] [V] OCMgr SetMeterValue PhId:0103, branchNo:01, valueId:301200, value:65047.000000, scaleFactor:1, devId:3
[2026-08-08 20:29:19.001 UTC] [V] 485DevCtl <C1:03> [01][301201][8952.000000][3][A]
[2026-08-08 20:29:19.001 UTC] [V] SummDat SetVrmValue dev_id:3 val:8952.000000 sc:3
[2026-08-08 20:29:19.001 UTC] [V] OCMgr SetMeterValue PhId:0103, branchNo:01, valueId:301201, value:8952.000000, scaleFactor:3, devId:3
[2026-08-08 20:29:19.002 UTC] [V] OFSCtrl Rcv set p_grid:109590.000000
[2026-08-08 20:29:19.002 UTC] [V] 485DevCtl <C1:03> [01][601202][10959.000000][2][kW]
[2026-08-08 20:29:19.010 UTC] [V] 485ChCtl <C2> StartDeviceCommunicationForOutputFluctuationSuppressionControlBroadcast 4 cnt:3604836, monitor_cnt:54, bc_elapsed:3604836, min:10, max:40
[2026-08-08 20:29:19.011 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :1
[2026-08-08 20:29:19.011 UTC] [V] 485ChCtl <C2> send request:Sungrow08
[2026-08-08 20:29:19.012 UTC] [D] 485AcReq <C2:02> PutOStream [1][08000204138a0024d54c]
[2026-08-08 20:29:19.023 UTC] [V] SummDat SetVrmValue dev_id:3 val:109590.000000 sc:3
[2026-08-08 20:29:19.024 UTC] [V] OCMgr SetMeterValue PhId:0103, branchNo:01, valueId:601202, value:10959.000000, scaleFactor:2, devId:3
[2026-08-08 20:29:19.024 UTC] [V] 485DevCtl <C1:03> device_type:Grid-Meter
[2026-08-08 20:29:19.027 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:19.028 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:19.038 UTC] [V] 485ChCtl <C1> set rt:0
[2026-08-08 20:29:19.093 UTC] [V] 485ChCtl <C1> StartDeviceCommunicationForOutputFluctuationSuppressionControlBroadcast 4 cnt:3604837, monitor_cnt:110, bc_elapsed:37, min:10, max:40
[2026-08-08 20:29:19.127 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:19.128 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:19.193 UTC] [V] 485ChCtl <C1> StartDeviceCommunicationForOutputFluctuationSuppressionControlBroadcast 4 cnt:3604838, monitor_cnt:111, bc_elapsed:38, min:10, max:40
[2026-08-08 20:29:19.193 UTC] [V] 485DevCtl <C1:05> Dev not PCS IsNeedToChangeOControlState
[2026-08-08 20:29:19.193 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :1
[2026-08-08 20:29:19.194 UTC] [V] 485ChCtl <C1> send request:omron04
[2026-08-08 20:29:19.195 UTC] [D] 485AcReq <C1:05> PutOStream [1][0800050300030014b441]
[2026-08-08 20:29:19.227 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:19.228 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:19.327 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:19.328 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:19.328 UTC] [V] OFSCtrl Control charge discharge proc start.
[2026-08-08 20:29:19.328 UTC] [V] OFSCtrl CHG 20 p_th(t):-1109.900000 = p_th_old_:-1100.000000 + lev_cd_:-0.300000 * (total_pcs_capacity_:99000.000000 * cof_spec_:2.000000 / 60 * (time_threshold_renew:10.000000 * 10)), min:-1100.000000, max:119300.000000
[2026-08-08 20:29:19.329 UTC] [V] OFSCtrl CHG 21 batt_w:313.182026 = old:316.619526 +  kp:0.550000 * e:-6.250000 + ki:0.000000 * sume:9163161.950228 + kd:0.040000 * (e:-6.250000 - e1:-6.250000)
[2026-08-08 20:29:19.330 UTC] [V] OFSCtrl CHG 29 q:3.000000, mod(round):0.000000
[2026-08-08 20:29:19.331 UTC] [D] OFSCtrl battery ctrl val:0.600000
[2026-08-08 20:29:19.331 UTC] [V] 485ChCtl <C3> battery limit on [3.000000,] request.
[2026-08-08 20:29:19.332 UTC] [V] OFSCtrl Control charge discharge proc:01->02->BATT_CHK->03->04->05->06->07->10->11->20->21->22->23->24->25->27->28->29->30->31->32->33->34
[2026-08-08 20:29:19.406 UTC] [V] Res no response condition. set normal condition.
[2026-08-08 20:29:19.408 UTC] [D] 485DevCtl <C2:02> RcvDat status[2] len[77] [0204480000024a0001171f000000000000000000000000000000000000000000000000000000000000000000000000ffffffffffffffffffffffff000000000000000000000000000014008841]
[2026-08-08 20:29:19.408 UTC] [D] 485DevCtl <C2:02> ResCnd OperationId [1] IsNormal[1] 
[2026-08-08 20:29:19.408 UTC] [V] 485DevCtl <C2:02> [01][115202][0.000000][1][kWh]
[2026-08-08 20:29:19.409 UTC] [V] SummDat SetVrmValue dev_id:8 val:0.000000 sc:1
[2026-08-08 20:29:19.409 UTC] [V] OCMgr SetMeterValue PhId:0202, branchNo:01, valueId:115202, value:0.000000, scaleFactor:1, devId:8
[2026-08-08 20:29:19.424 UTC] [V] 485DevCtl <C2:02> [01][113202][66122.000000][0][kWh]
[2026-08-08 20:29:19.426 UTC] [V] SummDat SetVrmValue dev_id:8 val:66122.000000 sc:0
[2026-08-08 20:29:19.426 UTC] [V] OCMgr SetMeterValue PhId:0202, branchNo:01, valueId:113202, value:66122.000000, scaleFactor:0, devId:8
[2026-08-08 20:29:19.426 UTC] [V] 485DevCtl <C2:02> [01][121005][0.000000][1][℃]
[2026-08-08 20:29:19.427 UTC] [V] SummDat SetVrmValue dev_id:8 val:0.000000 sc:3
[2026-08-08 20:29:19.427 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:19.428 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:19.430 UTC] [V] 485ChCtl <C3> battery send request.1
[2026-08-08 20:29:19.430 UTC] [D] VarInf Limit_Bat rt[2]set val[3] set rate[0.600000] value100[500] value-100[-500]
[2026-08-08 20:29:19.432 UTC] [D] 485AcReq <C3:01> PutOStream [6][0f000001000000090110278e0001020003]
[2026-08-08 20:29:19.427 UTC] [V] OCMgr SetMeterValue PhId:0202, branchNo:01, valueId:121005, value:0.000000, scaleFactor:1, devId:8
[2026-08-08 20:29:19.456 UTC] [V] 485DevCtl <C2:02> [01][101100][0.000000][1][V]
[2026-08-08 20:29:19.456 UTC] [V] SummDat SetVrmValue dev_id:8 val:0.000000 sc:3
[2026-08-08 20:29:19.456 UTC] [V] OCMgr SetMeterValue PhId:0202, branchNo:01, valueId:101100, value:0.000000, scaleFactor:1, devId:8
[2026-08-08 20:29:19.460 UTC] [V] 485DevCtl <C2:02> [01][101101][0.000000][1][A]
[2026-08-08 20:29:19.462 UTC] [V] SummDat SetVrmValue dev_id:8 val:0.000000 sc:3
[2026-08-08 20:29:19.471 UTC] [V] OCMgr SetMeterValue PhId:0202, branchNo:01, valueId:101101, value:0.000000, scaleFactor:1, devId:8
[2026-08-08 20:29:19.472 UTC] [V] 485DevCtl <C2:02> [02][101100][0.000000][1][V]
[2026-08-08 20:29:19.472 UTC] [V] SummDat SetVrmValue dev_id:8 val:0.000000 sc:3
[2026-08-08 20:29:19.473 UTC] [V] OCMgr SetMeterValue PhId:0202, branchNo:02, valueId:101100, value:0.000000, scaleFactor:1, devId:8
[2026-08-08 20:29:19.473 UTC] [V] 485DevCtl <C2:02> [02][101101][0.000000][1][A]
[2026-08-08 20:29:19.473 UTC] [V] SummDat SetVrmValue dev_id:8 val:0.000000 sc:3
[2026-08-08 20:29:19.482 UTC] [V] OCMgr SetMeterValue PhId:0202, branchNo:02, valueId:101101, value:0.000000, scaleFactor:1, devId:8
[2026-08-08 20:29:19.488 UTC] [V] 485DevCtl <C2:02> [03][101100][0.000000][1][V]
[2026-08-08 20:29:19.494 UTC] [V] SummDat SetVrmValue dev_id:8 val:0.000000 sc:3
[2026-08-08 20:29:19.498 UTC] [V] OCMgr SetMeterValue PhId:0202, branchNo:03, valueId:101100, value:0.000000, scaleFactor:1, devId:8
[2026-08-08 20:29:19.498 UTC] [V] 485DevCtl <C2:02> [03][101101][0.000000][1][A]
[2026-08-08 20:29:19.498 UTC] [V] SummDat SetVrmValue dev_id:8 val:0.000000 sc:3
[2026-08-08 20:29:19.508 UTC] [V] OCMgr SetMeterValue PhId:0202, branchNo:03, valueId:101101, value:0.000000, scaleFactor:1, devId:8
[2026-08-08 20:29:19.511 UTC] [V] 485DevCtl <C2:02> [01][101102][0.000000][0][W]
[2026-08-08 20:29:19.511 UTC] [V] SummDat SetVrmValue dev_id:8 val:0.000000 sc:3
[2026-08-08 20:29:19.520 UTC] [V] OCMgr SetMeterValue PhId:0202, branchNo:01, valueId:101102, value:0.000000, scaleFactor:0, devId:8
[2026-08-08 20:29:19.524 UTC] [V] 485DevCtl <C2:02> [01][111200][0.000000][1][V]
[2026-08-08 20:29:19.524 UTC] [V] SummDat SetVrmValue dev_id:8 val:0.000000 sc:3
[2026-08-08 20:29:19.527 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:19.527 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:19.529 UTC] [V] OCMgr SetMeterValue PhId:0202, branchNo:01, valueId:111200, value:0.000000, scaleFactor:1, devId:8
[2026-08-08 20:29:19.532 UTC] [V] 485DevCtl <C2:02> [02][111200][0.000000][1][V]
[2026-08-08 20:29:19.536 UTC] [V] SummDat SetVrmValue dev_id:8 val:0.000000 sc:3
[2026-08-08 20:29:19.545 UTC] [V] OCMgr SetMeterValue PhId:0202, branchNo:02, valueId:111200, value:0.000000, scaleFactor:1, devId:8
[2026-08-08 20:29:19.547 UTC] [V] 485DevCtl <C2:02> [03][111200][0.000000][1][V]
[2026-08-08 20:29:19.549 UTC] [V] SummDat SetVrmValue dev_id:8 val:0.000000 sc:3
[2026-08-08 20:29:19.557 UTC] [V] OCMgr SetMeterValue PhId:0202, branchNo:03, valueId:111200, value:0.000000, scaleFactor:1, devId:8
[2026-08-08 20:29:19.563 UTC] [V] 485DevCtl <C2:02> [01][111201][0.000000][1][A]
[2026-08-08 20:29:19.563 UTC] [V] SummDat SetVrmValue dev_id:8 val:0.000000 sc:3
[2026-08-08 20:29:19.563 UTC] [V] OCMgr SetMeterValue PhId:0202, branchNo:01, valueId:111201, value:0.000000, scaleFactor:1, devId:8
[2026-08-08 20:29:19.569 UTC] [V] 485DevCtl <C2:02> [02][111201][0.000000][1][A]
[2026-08-08 20:29:19.571 UTC] [V] SummDat SetVrmValue dev_id:8 val:0.000000 sc:3
[2026-08-08 20:29:19.575 UTC] [V] OCMgr SetMeterValue PhId:0202, branchNo:02, valueId:111201, value:0.000000, scaleFactor:1, devId:8
[2026-08-08 20:29:19.576 UTC] [V] 485DevCtl <C2:02> [03][111201][0.000000][1][A]
[2026-08-08 20:29:19.576 UTC] [V] SummDat SetVrmValue dev_id:8 val:0.000000 sc:3
[2026-08-08 20:29:19.576 UTC] [V] OCMgr SetMeterValue PhId:0202, branchNo:03, valueId:111201, value:0.000000, scaleFactor:1, devId:8
[2026-08-08 20:29:19.576 UTC] [V] 485DevCtl <C2:02> [01][111202][0.000000][0][W]
[2026-08-08 20:29:19.576 UTC] [V] SummDat SetVrmValue dev_id:8 val:0.000000 sc:3
[2026-08-08 20:29:19.587 UTC] [V] 485DevCtl <C3:01> AnalyzeResponseData proc restart cnt:360479 UPRstat:0
[2026-08-08 20:29:19.591 UTC] [V] 485DevCtl <C1:05> AnalyzeResponseData proc restart cnt:360472 UPRstat:0
[2026-08-08 20:29:19.592 UTC] [V] Res no response condition. set normal condition.
[2026-08-08 20:29:19.593 UTC] [D] 485DevCtl <C1:05> RcvDat status[2] len[45] [05032800002090000015b1000016aaffffffda00000257ffffdf3affffffadffffb18fffffff3800138539727b]
[2026-08-08 20:29:19.593 UTC] [D] 485DevCtl <C1:05> ResCnd OperationId [1] IsNormal[1] 
[2026-08-08 20:29:19.596 UTC] [V] OFSCtrl Rcv set p_pv:-830.000000
[2026-08-08 20:29:19.596 UTC] [V] 485DevCtl <C1:05> [01][601259][-83.000000][2][kW]
[2026-08-08 20:29:19.596 UTC] [V] SummDat SetVrmValue dev_id:5 val:-830.000000 sc:3
[2026-08-08 20:29:19.597 UTC] [V] OCMgr SetMeterValue PhId:0105, branchNo:01, valueId:601259, value:-83.000000, scaleFactor:2, devId:5
[2026-08-08 20:29:19.597 UTC] [V] 485DevCtl <C1:05> [01][603259][1279289.000000][1][kWh]
[2026-08-08 20:29:19.597 UTC] [V] SummDat SetVrmValue dev_id:5 val:1279289.000000 sc:1
[2026-08-08 20:29:19.598 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-08 20:29:19.598 UTC] [D] 485DevCtl <C3:01> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-08 20:29:19.598 UTC] [D] 485DevCtl <C3:01> ResCnd OperationId [6] IsNormal[1] 
[2026-08-08 20:29:19.598 UTC] [V] 485DevCtl <C3:01> device_type:Battery
[2026-08-08 20:29:19.599 UTC] [V] 485ChCtl <C3> set rt:0
[2026-08-08 20:29:19.602 UTC] [V] OCMgr SetMeterValue PhId:0202, branchNo:01, valueId:111202, value:0.000000, scaleFactor:0, devId:8
[2026-08-08 20:29:19.607 UTC] [V] OCMgr SetMeterValue PhId:0105, branchNo:01, valueId:603259, value:1279289.000000, scaleFactor:1, devId:5
[2026-08-08 20:29:19.608 UTC] [V] 485DevCtl <C1:05> device_type:PV-Meter
[2026-08-08 20:29:19.609 UTC] [V] 485DevCtl <C2:02> [01][111203][0.000000][0][var]
[2026-08-08 20:29:19.609 UTC] [V] SummDat SetVrmValue dev_id:8 val:0.000000 sc:3
[2026-08-08 20:29:19.609 UTC] [V] OCMgr SetMeterValue PhId:0202, branchNo:01, valueId:111203, value:0.000000, scaleFactor:0, devId:8
[2026-08-08 20:29:19.609 UTC] [V] 485DevCtl <C2:02> [01][121007][0.000000][3][]
[2026-08-08 20:29:19.620 UTC] [V] 485ChCtl <C1> set rt:0
[2026-08-08 20:29:19.620 UTC] [V] SummDat SetVrmValue dev_id:8 val:0.000000 sc:3
[2026-08-08 20:29:19.626 UTC] [V] OCMgr SetMeterValue PhId:0202, branchNo:01, valueId:121007, value:0.000000, scaleFactor:3, devId:8
[2026-08-08 20:29:19.628 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:19.628 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:19.631 UTC] [V] 485DevCtl <C2:02> [01][131006][0.000000][1][Hz]
[2026-08-08 20:29:19.631 UTC] [V] SummDat SetVrmValue dev_id:8 val:0.000000 sc:3
[2026-08-08 20:29:19.631 UTC] [V] OCMgr SetMeterValue PhId:0202, branchNo:01, valueId:131006, value:0.000000, scaleFactor:1, devId:8
[2026-08-08 20:29:19.631 UTC] [V] 485DevCtl <C2:02> [01][114202][66122.000000][0][kWh]
[2026-08-08 20:29:19.632 UTC] [V] SummDat SetVrmValue dev_id:8 val:66122000.000000 sc:3
[2026-08-08 20:29:19.632 UTC] [V] OCMgr SetMeterValue PhId:0202, branchNo:01, valueId:114202, value:66122.000000, scaleFactor:0, devId:8
[2026-08-08 20:29:19.632 UTC] [V] 485DevCtl <C2:02> device_type:PV-PCS
[2026-08-08 20:29:19.633 UTC] [V] 485DevCtl <C2:02> set2 StatusCode[010100] DeviceName[] DeviceNumber[]
[2026-08-08 20:29:19.633 UTC] [V] 485ChCtl <C2> set rt:0
[2026-08-08 20:29:19.646 UTC] [D] 485ChCtl <C2> monitoring dev All Send
[2026-08-08 20:29:19.679 UTC] [V] OFSCtrl [/var/local/solajithome/function/output_fluctuation_suppression/batt_data] write success.
[2026-08-08 20:29:19.693 UTC] [V] 485ChCtl <C1> monitor no transmission period.
[2026-08-08 20:29:19.728 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:19.728 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:19.793 UTC] [V] 485ChCtl <C1> monitor no transmission period.
[2026-08-08 20:29:19.828 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:19.828 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:19.892 UTC] [V] 485ChCtl <C1> monitor no transmission period.
[2026-08-08 20:29:19.928 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:19.928 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:19.993 UTC] [V] 485ChCtl <C1> monitor no transmission period.
[2026-08-08 20:29:20.028 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:20.028 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:20.093 UTC] [V] 485ChCtl <C1> monitor no transmission period.
[2026-08-08 20:29:20.128 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:20.128 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:20.193 UTC] [V] 485ChCtl <C1> monitor no transmission period.
[2026-08-08 20:29:20.228 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:20.228 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:20.293 UTC] [V] 485ChCtl <C1> monitor no transmission period.
[2026-08-08 20:29:20.327 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:20.328 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:20.328 UTC] [V] OFSCtrl Control charge discharge proc start.
[2026-08-08 20:29:20.328 UTC] [V] OFSCtrl CHG 20 p_th(t):-1109.900000 = p_th_old_:-1100.000000 + lev_cd_:-0.300000 * (total_pcs_capacity_:99000.000000 * cof_spec_:2.000000 / 60 * (time_threshold_renew:10.000000 * 10)), min:-1100.000000, max:119300.000000
[2026-08-08 20:29:20.328 UTC] [V] OFSCtrl CHG 21 batt_w:309.744526 = old:313.182026 +  kp:0.550000 * e:-6.250000 + ki:0.000000 * sume:9163155.700228 + kd:0.040000 * (e:-6.250000 - e1:-6.250000)
[2026-08-08 20:29:20.329 UTC] [V] OFSCtrl CHG 29 q:3.000000, mod(round):0.000000
[2026-08-08 20:29:20.329 UTC] [D] OFSCtrl battery ctrl val:0.600000
[2026-08-08 20:29:20.329 UTC] [V] 485ChCtl <C3> battery limit on [3.000000,] request.
[2026-08-08 20:29:20.329 UTC] [V] OFSCtrl Control charge discharge proc:01->02->BATT_CHK->03->04->05->06->07->10->11->20->21->22->23->24->25->27->28->29->30->31->32->33->34
[2026-08-08 20:29:20.329 UTC] [V] 485ChCtl <C3> battery send request.1
[2026-08-08 20:29:20.330 UTC] [D] VarInf Limit_Bat rt[2]set val[3] set rate[0.600000] value100[500] value-100[-500]
[2026-08-08 20:29:20.331 UTC] [D] 485AcReq <C3:01> PutOStream [6][0f000001000000090110278e0001020003]
[2026-08-08 20:29:20.393 UTC] [V] 485DevCtl <C1:01> device_type:Irr-Meter
[2026-08-08 20:29:20.393 UTC] [V] 485DevCtl <C1:01> device_type:Irr-Meter
[2026-08-08 20:29:20.394 UTC] [V] 485ChCtl <C1> fixed cycle Irr-Meter
[2026-08-08 20:29:20.394 UTC] [V] 485DevCtl <C1:01> Dev not PCS IsNeedToChangeOControlState
[2026-08-08 20:29:20.394 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :1
[2026-08-08 20:29:20.394 UTC] [V] 485ChCtl <C1> send request:Irr01
[2026-08-08 20:29:20.395 UTC] [D] 485AcReq <C1:01> PutOStream [1][080001040000000271cb]
[2026-08-08 20:29:20.428 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:20.428 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:20.487 UTC] [V] 485DevCtl <C3:01> AnalyzeResponseData proc restart cnt:360479 UPRstat:0
[2026-08-08 20:29:20.490 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-08 20:29:20.490 UTC] [D] 485DevCtl <C3:01> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-08 20:29:20.490 UTC] [D] 485DevCtl <C3:01> ResCnd OperationId [6] IsNormal[1] 
[2026-08-08 20:29:20.491 UTC] [V] 485DevCtl <C3:01> device_type:Battery
[2026-08-08 20:29:20.491 UTC] [V] 485ChCtl <C3> set rt:0
[2026-08-08 20:29:20.528 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:20.528 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:20.628 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:20.628 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:20.679 UTC] [V] OFSCtrl [/var/local/solajithome/function/output_fluctuation_suppression/batt_data] write success.
[2026-08-08 20:29:20.723 UTC] [V] 485DevCtl <C1:01> AnalyzeResponseData proc restart cnt:360481 UPRstat:0
[2026-08-08 20:29:20.724 UTC] [V] Res no response condition. set normal condition.
[2026-08-08 20:29:20.724 UTC] [D] 485DevCtl <C1:01> RcvDat status[2] len[9] [010404000002013b24]
[2026-08-08 20:29:20.724 UTC] [D] 485DevCtl <C1:01> ResCnd OperationId [1] IsNormal[1] 
[2026-08-08 20:29:20.725 UTC] [V] OFSCtrl Rcv set flux_of_solar:0.000000
[2026-08-08 20:29:20.725 UTC] [V] 485DevCtl <C1:01> [01][401006][0.000000][1][W/m2]
[2026-08-08 20:29:20.725 UTC] [V] SummDat SetVrmValue dev_id:1 val:0.000000 sc:3
[2026-08-08 20:29:20.725 UTC] [V] OCMgr SetMeterValue PhId:0101, branchNo:01, valueId:401006, value:0.000000, scaleFactor:1, devId:1
[2026-08-08 20:29:20.727 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:20.728 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:20.730 UTC] [V] 485ChCtl <C3> StartDeviceCommunicationForOutputFluctuationSuppressionControlBroadcast 4 cnt:3604853, monitor_cnt:50, bc_elapsed:3604853, min:10, max:40
[2026-08-08 20:29:20.730 UTC] [V] OFSCtrl /var/local/solajithome/function/output_fluctuation_suppression/state is exist:0
[2026-08-08 20:29:20.730 UTC] [V] 485DevCtl <C3:01> Dev not PCS IsNeedToChangeOControlState
[2026-08-08 20:29:20.730 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :1
[2026-08-08 20:29:20.731 UTC] [V] 485ChCtl <C3> send request:Sungrow11
[2026-08-08 20:29:20.732 UTC] [D] 485AcReq <C3:01> PutOStream [1][0c00000100000006010327470048]
[2026-08-08 20:29:20.727 UTC] [V] 485DevCtl <C1:01> [01][421005][263.000000][1][℃]
[2026-08-08 20:29:20.739 UTC] [V] SummDat SetVrmValue dev_id:1 val:26300.000000 sc:3
[2026-08-08 20:29:20.749 UTC] [V] OCMgr SetMeterValue PhId:0101, branchNo:01, valueId:421005, value:263.000000, scaleFactor:1, devId:1
[2026-08-08 20:29:20.750 UTC] [V] 485DevCtl <C1:01> device_type:Irr-Meter
[2026-08-08 20:29:20.750 UTC] [V] OFSCtrl Irr-Meter received.
[2026-08-08 20:29:20.750 UTC] [V] 485ChCtl <C1> set rt:0
[2026-08-08 20:29:20.768 UTC] [V] 485DevCtl <C1:01> device_type:Irr-Meter
[2026-08-08 20:29:20.793 UTC] [V] 485DevCtl <C1:04> device_type:CO-Meter
[2026-08-08 20:29:20.793 UTC] [V] 485DevCtl <C1:04> device_type:CO-Meter
[2026-08-08 20:29:20.793 UTC] [V] 485ChCtl <C1> fixed cycle CO-Meter
[2026-08-08 20:29:20.793 UTC] [V] 485DevCtl <C1:04> Dev not PCS IsNeedToChangeOControlState
[2026-08-08 20:29:20.793 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :1
[2026-08-08 20:29:20.794 UTC] [V] 485ChCtl <C1> send request:omron05
[2026-08-08 20:29:20.796 UTC] [D] 485AcReq <C1:04> PutOStream [1][0800040300030014b590]
[2026-08-08 20:29:20.827 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:20.828 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:20.917 UTC] [V] 485DevCtl <C3:01> AnalyzeResponseData proc restart cnt:360480 UPRstat:0
[2026-08-08 20:29:20.927 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:20.927 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:20.941 UTC] [D] 485DevCtl <C3:01> RcvDat status[0] len[153] [0001000000930103900001000200000000005500550000005500aa00a000fa000000fa0001000000000000000000000019ffffffffffffffffffffffffffffffffffffffffffff000100000000ffff0000ffffffffffffffffffffffffffffffffffff0fa0177003e800000e101388000a000a00000000195021c000000000000000550055ffe201f4ffff0000000000000000000000000003]
[2026-08-08 20:29:20.941 UTC] [D] 485DevCtl <C3:01> ResCnd OperationId [1] IsNormal[1]  ConditionType [lggrdev:Normal] Action[-1]
[2026-08-08 20:29:20.941 UTC] [V] 485DevCtl <C3:01> [01][753049][0.000000][0][]
[2026-08-08 20:29:20.947 UTC] [V] SummDat SetVrmValue dev_id:9 val:0.000000 sc:0
[2026-08-08 20:29:20.953 UTC] [V] OCMgr SetMeterValue PhId:0301, branchNo:01, valueId:753049, value:0.000000, scaleFactor:0, devId:9
[2026-08-08 20:29:20.974 UTC] [V] OFSCtrl Rcv set BATT(t-1)[0301]:0.006000 value:300.000000/50000 BATT(t-1):0.006000 <- 300.000000/50000
[2026-08-08 20:29:20.974 UTC] [V] 485DevCtl <C3:01> [01][753102][3.000000][1][kW]
[2026-08-08 20:29:20.974 UTC] [V] SummDat SetVrmValue dev_id:9 val:3.000000 sc:1
[2026-08-08 20:29:20.974 UTC] [V] OCMgr SetMeterValue PhId:0301, branchNo:01, valueId:753102, value:3.000000, scaleFactor:1, devId:9
[2026-08-08 20:29:20.975 UTC] [V] 485DevCtl <C3:01> device_type:Battery
[2026-08-08 20:29:20.990 UTC] [V] 485ChCtl <C3> set rt:0
[2026-08-08 20:29:20.991 UTC] [D] 485ChCtl <C3> monitoring dev All Send
[2026-08-08 20:29:21.027 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:21.027 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:21.127 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:21.127 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:21.197 UTC] [V] 485DevCtl <C1:04> AnalyzeResponseData proc restart cnt:360480 UPRstat:0
[2026-08-08 20:29:21.198 UTC] [V] Res no response condition. set normal condition.
[2026-08-08 20:29:21.199 UTC] [D] 485DevCtl <C1:04> RcvDat status[2] len[45] [0403280000223400001802000017edffffffe500000258ffffe8a9ffffffc5ffffaf83ffffff3200121a8120c5]
[2026-08-08 20:29:21.200 UTC] [D] 485DevCtl <C1:04> ResCnd OperationId [1] IsNormal[1] 
[2026-08-08 20:29:21.200 UTC] [V] OFSCtrl Rcv set p_co:-590.000000, p_co_old:-600.000000
[2026-08-08 20:29:21.200 UTC] [V] 485DevCtl <C1:04> [01][601260][-59.000000][2][kW]
[2026-08-08 20:29:21.200 UTC] [V] SummDat SetVrmValue dev_id:4 val:-590.000000 sc:3
[2026-08-08 20:29:21.201 UTC] [V] OCMgr SetMeterValue PhId:0104, branchNo:01, valueId:601260, value:-59.000000, scaleFactor:2, devId:4
[2026-08-08 20:29:21.201 UTC] [V] 485DevCtl <C1:04> [01][603260][1186433.000000][1][kWh]
[2026-08-08 20:29:21.201 UTC] [V] SummDat SetVrmValue dev_id:4 val:1186433.000000 sc:1
[2026-08-08 20:29:21.201 UTC] [V] OCMgr SetMeterValue PhId:0104, branchNo:01, valueId:603260, value:1186433.000000, scaleFactor:1, devId:4
[2026-08-08 20:29:21.202 UTC] [V] 485DevCtl <C1:04> device_type:CO-Meter
[2026-08-08 20:29:21.202 UTC] [V] OFSCtrl km50 received.
[2026-08-08 20:29:21.202 UTC] [V] OFSCtrl omron05_local_date :2026/08/09 ? 2026/08/09
[2026-08-08 20:29:21.202 UTC] [V] OFSCtrl omron05_local_time :2026/08/09 05 ? 2026/08/09 05
[2026-08-08 20:29:21.202 UTC] [V] OFSCtrl out of control time.
[2026-08-08 20:29:21.202 UTC] [V] OFSCtrl Control pv-pcs proc start.
[2026-08-08 20:29:21.220 UTC] [V] OFSCtrl NOD_month:-1664.000000 = (NOD_month:306 - ((nod_max_/30):23.333333 * (cnt-1):25) * (30/cnt):6.000000 
[2026-08-08 20:29:21.223 UTC] [V] OFSCtrl PCS ratio_month:232.646617 = -k_inhibition_ratio_month:-0.097744 * NOD_month:-1664.000000 + inhibition_ratio_max:70
[2026-08-08 20:29:21.224 UTC] [V] OFSCtrl PCS 05 inhibition_ratio:70.000000 = max(ratio_min:5, min(ratio:70, ratio_hour:70.000000, ratio_day:70.000000, ratio_month:232.646617))
[2026-08-08 20:29:21.227 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:21.227 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:21.228 UTC] [D] OFSCtrl pv-pcs ctrl val:0.000000 old:0.000000
[2026-08-08 20:29:21.229 UTC] [V] OCHisDB set rate:0 t_rate:0 cnt:51
[2026-08-08 20:29:21.231 UTC] [V] 485ChCtl <C2> pv-pcs limit on [0.000000] request.
[2026-08-08 20:29:21.233 UTC] [V] OFSCtrl Control pv-pcs proc:BATT_CHK->01->02->03->04->05->06->07->09->09->10->11->12
[2026-08-08 20:29:21.234 UTC] [V] OFSCtrl Nod calc proc start.
[2026-08-08 20:29:21.241 UTC] [V] OFSCtrl ProcNodCountCalculation culc nod skip stop:0, pause:0, ctl_time:0
[2026-08-08 20:29:21.241 UTC] [V] OFSCtrl update p_co_old:-590.000000
[2026-08-08 20:29:21.241 UTC] [V] OFSCtrl Nod calc proc:
[2026-08-08 20:29:21.242 UTC] [V] 485ChCtl <C1> set rt:0
[2026-08-08 20:29:21.242 UTC] [V] 485DevCtl <C1:04> device_type:CO-Meter
[2026-08-08 20:29:21.293 UTC] [V] 485ChCtl <C1> monitor no transmission period.
[2026-08-08 20:29:21.309 UTC] [V] 485ChCtl <C2> pv-pcs send request.
[2026-08-08 20:29:21.310 UTC] [D] VarInf update ofs_rate:0.000000
[2026-08-08 20:29:21.310 UTC] [V] VarInf LimitSet rt[2] val[170] key[ValueOn]
[2026-08-08 20:29:21.310 UTC] [D] VarInf output_mode:8
[2026-08-08 20:29:21.310 UTC] [D] VarInf update ofs_rate:0.000000
[2026-08-08 20:29:21.310 UTC] [D] VarInf Limit setRate[0.000000] rate[0.000000] value100[1000.000000] value0[0.000000]
[2026-08-08 20:29:21.310 UTC] [V] 485DevCtl <C2:01> ChangeOutputRateToDevice rate:0.000000 set_rate1
[2026-08-08 20:29:21.310 UTC] [D] VarInf Limit rt[2] int_set_rate[1] server_rate[0.000000] rated_output[100.000000] solar_battery_power[100.000000]
[2026-08-08 20:29:21.312 UTC] [D] 485AcReq <C2:01> PutOStreamForBc [3][0d000010138e00020400aa0001466f]
[2026-08-08 20:29:21.328 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:21.328 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:21.328 UTC] [V] OFSCtrl Control charge discharge proc start.
[2026-08-08 20:29:21.329 UTC] [V] OFSCtrl CHG 20 p_th(t):-1109.900000 = p_th_old_:-1100.000000 + lev_cd_:-0.300000 * (total_pcs_capacity_:99000.000000 * cof_spec_:2.000000 / 60 * (time_threshold_renew:10.000000 * 10)), min:-1100.000000, max:119300.000000
[2026-08-08 20:29:21.329 UTC] [V] OFSCtrl CHG 21 batt_w:306.307026 = old:309.744526 +  kp:0.550000 * e:-6.250000 + ki:0.000000 * sume:9163149.450228 + kd:0.040000 * (e:-6.250000 - e1:-6.250000)
[2026-08-08 20:29:21.329 UTC] [V] OFSCtrl CHG 29 q:3.000000, mod(round):0.000000
[2026-08-08 20:29:21.330 UTC] [D] OFSCtrl battery ctrl val:0.600000
[2026-08-08 20:29:21.330 UTC] [V] 485ChCtl <C3> battery limit on [3.000000,] request.
[2026-08-08 20:29:21.330 UTC] [V] OFSCtrl Control charge discharge proc:01->02->BATT_CHK->03->04->05->06->07->10->11->20->21->22->23->24->25->27->28->29->30->31->32->33->34
[2026-08-08 20:29:21.393 UTC] [V] 485ChCtl <C1> monitor no transmission period.
[2026-08-08 20:29:21.428 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:21.428 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:21.429 UTC] [V] 485ChCtl <C3> battery send request.1
[2026-08-08 20:29:21.430 UTC] [D] VarInf Limit_Bat rt[2]set val[3] set rate[0.600000] value100[500] value-100[-500]
[2026-08-08 20:29:21.431 UTC] [D] 485AcReq <C3:01> PutOStream [6][0f000001000000090110278e0001020003]
[2026-08-08 20:29:21.493 UTC] [V] 485ChCtl <C1> StartDeviceCommunicationForOutputFluctuationSuppressionControlBroadcast 4 cnt:3604861, monitor_cnt:134, bc_elapsed:11, min:10, max:40
[2026-08-08 20:29:21.493 UTC] [V] 485DevCtl <C1:06> Dev not PCS IsNeedToChangeOControlState
[2026-08-08 20:29:21.493 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :1
[2026-08-08 20:29:21.494 UTC] [V] 485ChCtl <C1> send request:omron06
[2026-08-08 20:29:21.495 UTC] [D] 485AcReq <C1:06> PutOStream [1][08000603000000144472]
[2026-08-08 20:29:21.528 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:21.528 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:21.587 UTC] [V] 485DevCtl <C3:01> AnalyzeResponseData proc restart cnt:360481 UPRstat:0
[2026-08-08 20:29:21.590 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-08 20:29:21.591 UTC] [D] 485DevCtl <C3:01> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-08 20:29:21.591 UTC] [D] 485DevCtl <C3:01> ResCnd OperationId [6] IsNormal[1] 
[2026-08-08 20:29:21.591 UTC] [V] 485DevCtl <C3:01> device_type:Battery
[2026-08-08 20:29:21.591 UTC] [V] 485ChCtl <C3> set rt:0
[2026-08-08 20:29:21.603 UTC] [V] 485ChCtl <C2> set rt:0
[2026-08-08 20:29:21.627 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:21.628 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:21.679 UTC] [V] OFSCtrl [/var/local/solajithome/function/output_fluctuation_suppression/batt_data] write success.
[2026-08-08 20:29:21.727 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:21.728 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:21.827 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:21.827 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:21.889 UTC] [V] 485DevCtl <C1:06> AnalyzeResponseData proc restart cnt:360474 UPRstat:0
[2026-08-08 20:29:21.889 UTC] [V] Res no response condition. set normal condition.
[2026-08-08 20:29:21.890 UTC] [D] 485DevCtl <C1:06> RcvDat status[2] len[45] [06032800000803000008120000081100000a0700000a3100000910000000640000025700000b0b0000001c4b96]
[2026-08-08 20:29:21.890 UTC] [D] 485DevCtl <C1:06> ResCnd OperationId [1] IsNormal[1] 
[2026-08-08 20:29:21.891 UTC] [V] OFSCtrl Rcv set p_batt:280.000000
[2026-08-08 20:29:21.891 UTC] [V] 485DevCtl <C1:06> [01][601237][28.000000][2][kW]
[2026-08-08 20:29:21.891 UTC] [V] SummDat SetVrmValue dev_id:6 val:280.000000 sc:3
[2026-08-08 20:29:21.892 UTC] [V] OCMgr SetMeterValue PhId:0106, branchNo:01, valueId:601237, value:28.000000, scaleFactor:2, devId:6
[2026-08-08 20:29:21.892 UTC] [V] 485DevCtl <C1:06> device_type:Batt-Meter
[2026-08-08 20:29:21.892 UTC] [V] 485ChCtl <C1> set rt:0
[2026-08-08 20:29:21.894 UTC] [D] 485ChCtl <C1> monitoring dev All Send
[2026-08-08 20:29:21.927 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:21.928 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:22.028 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:22.028 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:22.128 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:22.128 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:22.228 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:22.228 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:22.328 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:22.328 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:22.328 UTC] [V] OFSCtrl Control charge discharge proc start.
[2026-08-08 20:29:22.328 UTC] [V] OFSCtrl CHG 20 p_th(t):-1109.900000 = p_th_old_:-1100.000000 + lev_cd_:-0.300000 * (total_pcs_capacity_:99000.000000 * cof_spec_:2.000000 / 60 * (time_threshold_renew:10.000000 * 10)), min:-1100.000000, max:119300.000000
[2026-08-08 20:29:22.329 UTC] [V] OFSCtrl CHG 21 batt_w:302.869526 = old:306.307026 +  kp:0.550000 * e:-6.250000 + ki:0.000000 * sume:9163143.200228 + kd:0.040000 * (e:-6.250000 - e1:-6.250000)
[2026-08-08 20:29:22.329 UTC] [V] OFSCtrl CHG 29 q:3.000000, mod(round):0.000000
[2026-08-08 20:29:22.329 UTC] [D] OFSCtrl battery ctrl val:0.600000
[2026-08-08 20:29:22.330 UTC] [V] 485ChCtl <C3> battery send request.1
[2026-08-08 20:29:22.330 UTC] [D] VarInf Limit_Bat rt[2]set val[3] set rate[0.600000] value100[500] value-100[-500]
[2026-08-08 20:29:22.332 UTC] [D] 485AcReq <C3:01> PutOStream [6][0f000001000000090110278e0001020003]
[2026-08-08 20:29:22.329 UTC] [V] 485ChCtl <C3> battery limit on [3.000000,] request.
[2026-08-08 20:29:22.336 UTC] [V] OFSCtrl Control charge discharge proc:01->02->BATT_CHK->03->04->05->06->07->10->11->20->21->22->23->24->25->27->28->29->30->31->32->33->34
[2026-08-08 20:29:22.427 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:22.428 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:22.487 UTC] [V] 485DevCtl <C3:01> AnalyzeResponseData proc restart cnt:360481 UPRstat:0
[2026-08-08 20:29:22.490 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-08 20:29:22.490 UTC] [D] 485DevCtl <C3:01> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-08 20:29:22.491 UTC] [D] 485DevCtl <C3:01> ResCnd OperationId [6] IsNormal[1] 
[2026-08-08 20:29:22.491 UTC] [V] 485DevCtl <C3:01> device_type:Battery
[2026-08-08 20:29:22.491 UTC] [V] 485ChCtl <C3> set rt:0
[2026-08-08 20:29:22.527 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:22.528 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:22.627 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:22.627 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:22.679 UTC] [V] OFSCtrl [/var/local/solajithome/function/output_fluctuation_suppression/batt_data] write success.
[2026-08-08 20:29:22.727 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:22.727 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:22.827 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:22.827 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:22.927 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:22.927 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:23.027 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:23.027 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:23.127 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:23.127 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:23.228 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:23.228 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:23.328 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:23.328 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:23.328 UTC] [V] OFSCtrl Control charge discharge proc start.
[2026-08-08 20:29:23.328 UTC] [V] OFSCtrl CHG 20 p_th(t):-1109.900000 = p_th_old_:-1100.000000 + lev_cd_:-0.300000 * (total_pcs_capacity_:99000.000000 * cof_spec_:2.000000 / 60 * (time_threshold_renew:10.000000 * 10)), min:-1100.000000, max:119300.000000
[2026-08-08 20:29:23.329 UTC] [V] OFSCtrl CHG 21 batt_w:299.432026 = old:302.869526 +  kp:0.550000 * e:-6.250000 + ki:0.000000 * sume:9163136.950228 + kd:0.040000 * (e:-6.250000 - e1:-6.250000)
[2026-08-08 20:29:23.329 UTC] [V] OFSCtrl CHG 29 q:2.000000, mod(round):1.000000
[2026-08-08 20:29:23.329 UTC] [D] OFSCtrl battery ctrl val:0.600000
[2026-08-08 20:29:23.330 UTC] [V] 485ChCtl <C3> battery limit on [3.000000,] request.
[2026-08-08 20:29:23.331 UTC] [V] OFSCtrl Control charge discharge proc:01->02->BATT_CHK->03->04->05->06->07->10->11->20->21->22->23->24->25->27->28->29->30->31->32->33->34
[2026-08-08 20:29:23.428 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:23.428 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:23.429 UTC] [V] 485ChCtl <C3> battery send request.1
[2026-08-08 20:29:23.430 UTC] [D] VarInf Limit_Bat rt[2]set val[3] set rate[0.600000] value100[500] value-100[-500]
[2026-08-08 20:29:23.432 UTC] [D] 485AcReq <C3:01> PutOStream [6][0f000001000000090110278e0001020003]
[2026-08-08 20:29:23.528 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:23.528 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:23.587 UTC] [V] 485DevCtl <C3:01> AnalyzeResponseData proc restart cnt:360483 UPRstat:0
[2026-08-08 20:29:23.589 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-08 20:29:23.590 UTC] [D] 485DevCtl <C3:01> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-08 20:29:23.590 UTC] [D] 485DevCtl <C3:01> ResCnd OperationId [6] IsNormal[1] 
[2026-08-08 20:29:23.590 UTC] [V] 485DevCtl <C3:01> device_type:Battery
[2026-08-08 20:29:23.590 UTC] [V] 485ChCtl <C3> set rt:0
[2026-08-08 20:29:23.627 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:23.628 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:23.679 UTC] [V] OFSCtrl [/var/local/solajithome/function/output_fluctuation_suppression/batt_data] write success.
[2026-08-08 20:29:23.727 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:23.727 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:23.827 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:23.827 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:23.928 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:23.928 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:24.010 UTC] [V] 485ChCtl <C2> StartDeviceCommunicationForOutputFluctuationSuppressionControlBroadcast 4 cnt:3604886, monitor_cnt:50, bc_elapsed:3604886, min:10, max:40
[2026-08-08 20:29:24.010 UTC] [V] OFSCtrl /var/local/solajithome/function/output_fluctuation_suppression/state is exist:0
[2026-08-08 20:29:24.010 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :4
[2026-08-08 20:29:24.011 UTC] [V] 485ChCtl <C2> send request:Sungrow08
[2026-08-08 20:29:24.012 UTC] [D] 485AcReq <C2:01> PutOStream [4][0800010413b400017568]
[2026-08-08 20:29:24.028 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:24.028 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:24.128 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:24.128 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:24.228 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:24.228 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:24.327 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:24.328 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:24.328 UTC] [V] OFSCtrl Control charge discharge proc start.
[2026-08-08 20:29:24.328 UTC] [V] OFSCtrl CHG 20 p_th(t):-1109.900000 = p_th_old_:-1100.000000 + lev_cd_:-0.300000 * (total_pcs_capacity_:99000.000000 * cof_spec_:2.000000 / 60 * (time_threshold_renew:10.000000 * 10)), min:-1100.000000, max:119300.000000
[2026-08-08 20:29:24.329 UTC] [V] OFSCtrl CHG 21 batt_w:295.994526 = old:299.432026 +  kp:0.550000 * e:-6.250000 + ki:0.000000 * sume:9163130.700228 + kd:0.040000 * (e:-6.250000 - e1:-6.250000)
[2026-08-08 20:29:24.330 UTC] [V] OFSCtrl CHG 29 q:2.000000, mod(round):1.000000
[2026-08-08 20:29:24.330 UTC] [D] OFSCtrl battery ctrl val:0.600000
[2026-08-08 20:29:24.330 UTC] [V] 485ChCtl <C3> battery limit on [3.000000,] request.
[2026-08-08 20:29:24.330 UTC] [V] OFSCtrl Control charge discharge proc:01->02->BATT_CHK->03->04->05->06->07->10->11->20->21->22->23->24->25->27->28->29->30->31->32->33->34
[2026-08-08 20:29:24.344 UTC] [D] 485DevCtl <C2:01> RcvDat status[2] len[7] [0104020000b930]
[2026-08-08 20:29:24.344 UTC] [D] 485DevCtl <C2:01> ResCnd OperationId [4] IsNormal[0]  ConditionType [lggrdev:Error] Action[-1]
[2026-08-08 20:29:24.345 UTC] [V] 485DevCtl <C2:01> device_type:PV-PCS
[2026-08-08 20:29:24.354 UTC] [V] 485ChCtl <C2> set rt:0
[2026-08-08 20:29:24.409 UTC] [V] 485ChCtl <C2> StartDeviceCommunicationForOutputFluctuationSuppressionControlBroadcast 4 cnt:3604890, monitor_cnt:54, bc_elapsed:3604890, min:10, max:40
[2026-08-08 20:29:24.410 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :2
[2026-08-08 20:29:24.410 UTC] [V] 485ChCtl <C2> send request:Sungrow08
[2026-08-08 20:29:24.411 UTC] [D] 485AcReq <C2:02> PutOStream [2][0800020413d80002f547]
[2026-08-08 20:29:24.427 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:24.427 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:24.430 UTC] [V] 485ChCtl <C3> battery send request.1
[2026-08-08 20:29:24.430 UTC] [D] VarInf Limit_Bat rt[2]set val[3] set rate[0.600000] value100[500] value-100[-500]
[2026-08-08 20:29:24.432 UTC] [D] 485AcReq <C3:01> PutOStream [6][0f000001000000090110278e0001020003]
[2026-08-08 20:29:24.528 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:24.528 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:24.577 UTC] [V] 485DevCtl <C3:01> AnalyzeResponseData proc restart cnt:360484 UPRstat:0
[2026-08-08 20:29:24.580 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-08 20:29:24.581 UTC] [D] 485DevCtl <C3:01> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-08 20:29:24.581 UTC] [D] 485DevCtl <C3:01> ResCnd OperationId [6] IsNormal[1] 
[2026-08-08 20:29:24.581 UTC] [V] 485DevCtl <C3:01> device_type:Battery
[2026-08-08 20:29:24.581 UTC] [V] 485ChCtl <C3> set rt:0
[2026-08-08 20:29:24.628 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:24.628 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:24.679 UTC] [V] OFSCtrl [/var/local/solajithome/function/output_fluctuation_suppression/batt_data] write success.
[2026-08-08 20:29:24.728 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:24.728 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:24.747 UTC] [D] 485DevCtl <C2:02> RcvDat status[2] len[9] [02040400100000c941]
[2026-08-08 20:29:24.748 UTC] [D] 485DevCtl <C2:02> ResCnd OperationId [2] IsNormal[0]  ConditionType [lggrdev:Error] Action[4]
[2026-08-08 20:29:24.749 UTC] [V] 485DevCtl <C2:02> device_type:PV-PCS
[2026-08-08 20:29:24.749 UTC] [V] 485DevCtl <C2:02> ExecuteAction name:RestartCounter value0
[2026-08-08 20:29:24.750 UTC] [V] 485DevCtl <C2:02> ExecuteAction set start cnt:0
[2026-08-08 20:29:24.754 UTC] [V] 485ChCtl <C2> set rt:0
[2026-08-08 20:29:24.755 UTC] [D] 485ChCtl <C2> monitoring dev All Send
[2026-08-08 20:29:24.828 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:24.828 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:24.928 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:24.928 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:25.029 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:25.029 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:25.127 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:25.127 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:25.228 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:25.228 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:25.328 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:25.328 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:25.328 UTC] [V] OFSCtrl Control charge discharge proc start.
[2026-08-08 20:29:25.328 UTC] [V] OFSCtrl CHG 20 p_th(t):-1109.900000 = p_th_old_:-1100.000000 + lev_cd_:-0.300000 * (total_pcs_capacity_:99000.000000 * cof_spec_:2.000000 / 60 * (time_threshold_renew:10.000000 * 10)), min:-1100.000000, max:119300.000000
[2026-08-08 20:29:25.329 UTC] [V] OFSCtrl CHG 21 batt_w:292.557026 = old:295.994526 +  kp:0.550000 * e:-6.250000 + ki:0.000000 * sume:9163124.450228 + kd:0.040000 * (e:-6.250000 - e1:-6.250000)
[2026-08-08 20:29:25.329 UTC] [V] OFSCtrl CHG 29 q:2.000000, mod(round):1.000000
[2026-08-08 20:29:25.329 UTC] [D] OFSCtrl battery ctrl val:0.600000
[2026-08-08 20:29:25.330 UTC] [V] 485ChCtl <C3> battery limit on [3.000000,] request.
[2026-08-08 20:29:25.330 UTC] [V] OFSCtrl Control charge discharge proc:01->02->BATT_CHK->03->04->05->06->07->10->11->20->21->22->23->24->25->27->28->29->30->31->32->33->34
[2026-08-08 20:29:25.393 UTC] [V] 485DevCtl <C1:01> device_type:Irr-Meter
[2026-08-08 20:29:25.393 UTC] [V] 485DevCtl <C1:01> device_type:Irr-Meter
[2026-08-08 20:29:25.393 UTC] [V] 485ChCtl <C1> fixed cycle Irr-Meter
[2026-08-08 20:29:25.394 UTC] [V] 485DevCtl <C1:01> Dev not PCS IsNeedToChangeOControlState
[2026-08-08 20:29:25.394 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :1
[2026-08-08 20:29:25.394 UTC] [V] 485ChCtl <C1> send request:Irr01
[2026-08-08 20:29:25.395 UTC] [D] 485AcReq <C1:01> PutOStream [1][080001040000000271cb]
[2026-08-08 20:29:25.428 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:25.428 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:25.430 UTC] [V] 485ChCtl <C3> battery send request.1
[2026-08-08 20:29:25.430 UTC] [D] VarInf Limit_Bat rt[2]set val[3] set rate[0.600000] value100[500] value-100[-500]
[2026-08-08 20:29:25.432 UTC] [D] 485AcReq <C3:01> PutOStream [6][0f000001000000090110278e0001020003]
[2026-08-08 20:29:25.527 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:25.527 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:25.577 UTC] [V] 485DevCtl <C3:01> AnalyzeResponseData proc restart cnt:360485 UPRstat:0
[2026-08-08 20:29:25.579 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-08 20:29:25.579 UTC] [D] 485DevCtl <C3:01> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-08 20:29:25.580 UTC] [D] 485DevCtl <C3:01> ResCnd OperationId [6] IsNormal[1] 
[2026-08-08 20:29:25.580 UTC] [V] 485DevCtl <C3:01> device_type:Battery
[2026-08-08 20:29:25.580 UTC] [V] 485ChCtl <C3> set rt:0
[2026-08-08 20:29:25.627 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:25.627 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:25.679 UTC] [V] OFSCtrl [/var/local/solajithome/function/output_fluctuation_suppression/batt_data] write success.
[2026-08-08 20:29:25.728 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:25.728 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:25.731 UTC] [V] 485ChCtl <C3> StartDeviceCommunicationForOutputFluctuationSuppressionControlBroadcast 4 cnt:3604903, monitor_cnt:50, bc_elapsed:3604903, min:10, max:40
[2026-08-08 20:29:25.731 UTC] [V] OFSCtrl /var/local/solajithome/function/output_fluctuation_suppression/state is exist:0
[2026-08-08 20:29:25.731 UTC] [V] 485DevCtl <C3:01> Dev not PCS IsNeedToChangeOControlState
[2026-08-08 20:29:25.731 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :2
[2026-08-08 20:29:25.732 UTC] [V] 485ChCtl <C3> send request:Sungrow11
[2026-08-08 20:29:25.732 UTC] [V] 485DevCtl <C1:01> AnalyzeResponseData proc restart cnt:360486 UPRstat:0
[2026-08-08 20:29:25.733 UTC] [V] Res no response condition. set normal condition.
[2026-08-08 20:29:25.733 UTC] [D] 485DevCtl <C1:01> RcvDat status[2] len[9] [010404000002013b24]
[2026-08-08 20:29:25.733 UTC] [D] 485DevCtl <C1:01> ResCnd OperationId [1] IsNormal[1] 
[2026-08-08 20:29:25.734 UTC] [V] OFSCtrl Rcv set flux_of_solar:0.000000
[2026-08-08 20:29:25.734 UTC] [V] 485DevCtl <C1:01> [01][401006][0.000000][1][W/m2]
[2026-08-08 20:29:25.734 UTC] [V] SummDat SetVrmValue dev_id:1 val:0.000000 sc:3
[2026-08-08 20:29:25.734 UTC] [V] OCMgr SetMeterValue PhId:0101, branchNo:01, valueId:401006, value:0.000000, scaleFactor:1, devId:1
[2026-08-08 20:29:25.735 UTC] [V] 485DevCtl <C1:01> [01][421005][263.000000][1][℃]
[2026-08-08 20:29:25.735 UTC] [V] SummDat SetVrmValue dev_id:1 val:26300.000000 sc:3
[2026-08-08 20:29:25.736 UTC] [D] 485AcReq <C3:01> PutOStream [2][0c0000010000000601042751005e]
[2026-08-08 20:29:25.740 UTC] [V] OCMgr SetMeterValue PhId:0101, branchNo:01, valueId:421005, value:263.000000, scaleFactor:1, devId:1
[2026-08-08 20:29:25.747 UTC] [V] 485DevCtl <C1:01> device_type:Irr-Meter
[2026-08-08 20:29:25.748 UTC] [V] OFSCtrl Irr-Meter received.
[2026-08-08 20:29:25.748 UTC] [V] 485ChCtl <C1> set rt:0
[2026-08-08 20:29:25.748 UTC] [V] 485DevCtl <C1:01> device_type:Irr-Meter
[2026-08-08 20:29:25.793 UTC] [V] 485DevCtl <C1:04> device_type:CO-Meter
[2026-08-08 20:29:25.793 UTC] [V] 485DevCtl <C1:04> device_type:CO-Meter
[2026-08-08 20:29:25.793 UTC] [V] 485ChCtl <C1> fixed cycle CO-Meter
[2026-08-08 20:29:25.793 UTC] [V] 485DevCtl <C1:04> Dev not PCS IsNeedToChangeOControlState
[2026-08-08 20:29:25.793 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :1
[2026-08-08 20:29:25.796 UTC] [V] 485ChCtl <C1> send request:omron05
[2026-08-08 20:29:25.797 UTC] [D] 485AcReq <C1:04> PutOStream [1][0800040300030014b590]
[2026-08-08 20:29:25.828 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:25.828 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:25.927 UTC] [V] 485DevCtl <C3:01> AnalyzeResponseData proc restart cnt:360485 UPRstat:0
[2026-08-08 20:29:25.928 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:25.928 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:25.944 UTC] [D] 485DevCtl <C3:01> RcvDat status[0] len[197] [0001000000bf0104bc0000ffffffffffff03ae00000000001000000000000000000000000000000000000000ae0032009a0000000100010001ffffffffffffffffffffffffffffffffffffffff000100000001000000010000ffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffff000101f40000000400000000000003e89df70000917100000000000000930000]
[2026-08-08 20:29:25.945 UTC] [D] 485DevCtl <C3:01> ResCnd OperationId [2] IsNormal[1]  ConditionType [lggrdev:Normal] Action[-1]
[2026-08-08 20:29:25.945 UTC] [V] 485DevCtl <C3:01> [02][753049][0.000000][0][]
[2026-08-08 20:29:25.945 UTC] [V] SummDat SetVrmValue dev_id:9 val:0.000000 sc:0
[2026-08-08 20:29:25.965 UTC] [V] OCMgr SetMeterValue PhId:0301, branchNo:02, valueId:753049, value:0.000000, scaleFactor:0, devId:9
[2026-08-08 20:29:25.976 UTC] [V] 485DevCtl <C3:01> [01][753040][16.000000][0][]
[2026-08-08 20:29:25.978 UTC] [V] SummDat SetVrmValue dev_id:9 val:16.000000 sc:0
[2026-08-08 20:29:25.981 UTC] [V] OCMgr SetMeterValue PhId:0301, branchNo:01, valueId:753040, value:16.000000, scaleFactor:0, devId:9
[2026-08-08 20:29:25.985 UTC] [V] 485DevCtl <C3:01> [01][753053][0.000000][0][]
[2026-08-08 20:29:25.986 UTC] [V] SummDat SetVrmValue dev_id:9 val:0.000000 sc:0
[2026-08-08 20:29:25.989 UTC] [V] OCMgr SetMeterValue PhId:0301, branchNo:01, valueId:753053, value:0.000000, scaleFactor:0, devId:9
[2026-08-08 20:29:25.992 UTC] [V] 485DevCtl <C3:01> [02][753053][0.000000][0][]
[2026-08-08 20:29:25.993 UTC] [V] SummDat SetVrmValue dev_id:9 val:0.000000 sc:0
[2026-08-08 20:29:25.998 UTC] [V] OCMgr SetMeterValue PhId:0301, branchNo:02, valueId:753053, value:0.000000, scaleFactor:0, devId:9
[2026-08-08 20:29:25.999 UTC] [V] 485DevCtl <C3:01> [03][753053][0.000000][0][]
[2026-08-08 20:29:25.999 UTC] [V] SummDat SetVrmValue dev_id:9 val:0.000000 sc:0
[2026-08-08 20:29:26.008 UTC] [V] OCMgr SetMeterValue PhId:0301, branchNo:03, valueId:753053, value:0.000000, scaleFactor:0, devId:9
[2026-08-08 20:29:26.014 UTC] [V] 485DevCtl <C3:01> [04][753053][0.000000][0][]
[2026-08-08 20:29:26.016 UTC] [V] SummDat SetVrmValue dev_id:9 val:0.000000 sc:0
[2026-08-08 20:29:26.023 UTC] [V] OCMgr SetMeterValue PhId:0301, branchNo:04, valueId:753053, value:0.000000, scaleFactor:0, devId:9
[2026-08-08 20:29:26.026 UTC] [V] 485DevCtl <C3:01> [01][716202][500.000000][1][kW]
[2026-08-08 20:29:26.028 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:26.028 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:26.030 UTC] [V] SummDat SetVrmValue dev_id:9 val:50.000000 sc:0
[2026-08-08 20:29:26.035 UTC] [V] OCMgr SetMeterValue PhId:0301, branchNo:01, valueId:716202, value:500.000000, scaleFactor:1, devId:9
[2026-08-08 20:29:26.040 UTC] [V] 485DevCtl <C3:01> [01][711102][4.000000][1][kW]
[2026-08-08 20:29:26.045 UTC] [V] SummDat SetVrmValue dev_id:9 val:400.000000 sc:3
[2026-08-08 20:29:26.046 UTC] [V] OCMgr SetMeterValue PhId:0301, branchNo:01, valueId:711102, value:4.000000, scaleFactor:1, devId:9
[2026-08-08 20:29:26.046 UTC] [V] 485DevCtl <C3:01> [01][703102][40439.000000][0][kWh]
[2026-08-08 20:29:26.048 UTC] [V] SummDat SetVrmValue dev_id:9 val:40439.000000 sc:0
[2026-08-08 20:29:26.052 UTC] [V] OCMgr SetMeterValue PhId:0301, branchNo:01, valueId:703102, value:40439.000000, scaleFactor:0, devId:9
[2026-08-08 20:29:26.055 UTC] [V] 485DevCtl <C3:01> [01][713102][37233.000000][0][kWh]
[2026-08-08 20:29:26.057 UTC] [V] SummDat SetVrmValue dev_id:9 val:37233.000000 sc:0
[2026-08-08 20:29:26.062 UTC] [V] OCMgr SetMeterValue PhId:0301, branchNo:01, valueId:713102, value:37233.000000, scaleFactor:0, devId:9
[2026-08-08 20:29:26.067 UTC] [V] 485DevCtl <C3:01> device_type:Battery
[2026-08-08 20:29:26.071 UTC] [V] 485ChCtl <C3> set rt:0
[2026-08-08 20:29:26.077 UTC] [D] 485ChCtl <C3> monitoring dev All Send
[2026-08-08 20:29:26.128 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:26.128 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:26.201 UTC] [V] 485DevCtl <C1:04> AnalyzeResponseData proc restart cnt:360485 UPRstat:0
[2026-08-08 20:29:26.201 UTC] [V] Res no response condition. set normal condition.
[2026-08-08 20:29:26.203 UTC] [D] 485DevCtl <C1:04> RcvDat status[2] len[45] [0403280000221800001802000017deffffffe500000258ffffe8cfffffffc5ffffaf7bffffff3200121a81e85b]
[2026-08-08 20:29:26.203 UTC] [D] 485DevCtl <C1:04> ResCnd OperationId [1] IsNormal[1] 
[2026-08-08 20:29:26.203 UTC] [V] OFSCtrl Rcv set p_co:-590.000000, p_co_old:-590.000000
[2026-08-08 20:29:26.204 UTC] [V] 485DevCtl <C1:04> [01][601260][-59.000000][2][kW]
[2026-08-08 20:29:26.204 UTC] [V] SummDat SetVrmValue dev_id:4 val:-590.000000 sc:3
[2026-08-08 20:29:26.205 UTC] [V] OCMgr SetMeterValue PhId:0104, branchNo:01, valueId:601260, value:-59.000000, scaleFactor:2, devId:4
[2026-08-08 20:29:26.205 UTC] [V] 485DevCtl <C1:04> [01][603260][1186433.000000][1][kWh]
[2026-08-08 20:29:26.205 UTC] [V] SummDat SetVrmValue dev_id:4 val:1186433.000000 sc:1
[2026-08-08 20:29:26.220 UTC] [V] OCMgr SetMeterValue PhId:0104, branchNo:01, valueId:603260, value:1186433.000000, scaleFactor:1, devId:4
[2026-08-08 20:29:26.221 UTC] [V] 485DevCtl <C1:04> device_type:CO-Meter
[2026-08-08 20:29:26.221 UTC] [V] OFSCtrl km50 received.
[2026-08-08 20:29:26.221 UTC] [V] OFSCtrl omron05_local_date :2026/08/09 ? 2026/08/09
[2026-08-08 20:29:26.221 UTC] [V] OFSCtrl omron05_local_time :2026/08/09 05 ? 2026/08/09 05
[2026-08-08 20:29:26.221 UTC] [V] OFSCtrl out of control time.
[2026-08-08 20:29:26.221 UTC] [V] OFSCtrl Control pv-pcs proc start.
[2026-08-08 20:29:26.222 UTC] [V] OFSCtrl NOD_month:-1664.000000 = (NOD_month:306 - ((nod_max_/30):23.333333 * (cnt-1):25) * (30/cnt):6.000000 
[2026-08-08 20:29:26.222 UTC] [V] OFSCtrl PCS ratio_month:232.646617 = -k_inhibition_ratio_month:-0.097744 * NOD_month:-1664.000000 + inhibition_ratio_max:70
[2026-08-08 20:29:26.222 UTC] [V] OFSCtrl PCS 05 inhibition_ratio:70.000000 = max(ratio_min:5, min(ratio:70, ratio_hour:70.000000, ratio_day:70.000000, ratio_month:232.646617))
[2026-08-08 20:29:26.223 UTC] [D] OFSCtrl pv-pcs ctrl val:0.000000 old:0.000000
[2026-08-08 20:29:26.223 UTC] [V] OCHisDB set rate:0 t_rate:0 cnt:52
[2026-08-08 20:29:26.223 UTC] [V] 485ChCtl <C2> pv-pcs limit on [0.000000] request.
[2026-08-08 20:29:26.223 UTC] [V] OFSCtrl Control pv-pcs proc:BATT_CHK->01->02->03->04->05->06->07->09->09->10->11->12
[2026-08-08 20:29:26.223 UTC] [V] 485ChCtl <C1> set rt:0
[2026-08-08 20:29:26.227 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:26.228 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:26.249 UTC] [V] 485DevCtl <C1:04> device_type:CO-Meter
[2026-08-08 20:29:26.310 UTC] [V] 485ChCtl <C2> pv-pcs send request.
[2026-08-08 20:29:26.310 UTC] [D] VarInf update ofs_rate:0.000000
[2026-08-08 20:29:26.310 UTC] [V] VarInf LimitSet rt[2] val[170] key[ValueOn]
[2026-08-08 20:29:26.310 UTC] [D] VarInf output_mode:8
[2026-08-08 20:29:26.310 UTC] [D] VarInf update ofs_rate:0.000000
[2026-08-08 20:29:26.310 UTC] [D] VarInf Limit setRate[0.000000] rate[0.000000] value100[1000.000000] value0[0.000000]
[2026-08-08 20:29:26.311 UTC] [V] 485DevCtl <C2:01> ChangeOutputRateToDevice rate:0.000000 set_rate1
[2026-08-08 20:29:26.311 UTC] [D] VarInf Limit rt[2] int_set_rate[1] server_rate[0.000000] rated_output[100.000000] solar_battery_power[100.000000]
[2026-08-08 20:29:26.312 UTC] [D] 485AcReq <C2:01> PutOStreamForBc [3][0d000010138e00020400aa0001466f]
[2026-08-08 20:29:26.327 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:26.327 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:26.328 UTC] [V] OFSCtrl Control charge discharge proc start.
[2026-08-08 20:29:26.328 UTC] [V] OFSCtrl CHG 20 p_th(t):-1109.900000 = p_th_old_:-1100.000000 + lev_cd_:-0.300000 * (total_pcs_capacity_:99000.000000 * cof_spec_:2.000000 / 60 * (time_threshold_renew:10.000000 * 10)), min:-1100.000000, max:119300.000000
[2026-08-08 20:29:26.328 UTC] [V] OFSCtrl CHG 21 batt_w:289.119526 = old:292.557026 +  kp:0.550000 * e:-6.250000 + ki:0.000000 * sume:9163118.200228 + kd:0.040000 * (e:-6.250000 - e1:-6.250000)
[2026-08-08 20:29:26.328 UTC] [V] OFSCtrl CHG 29 q:2.000000, mod(round):1.000000
[2026-08-08 20:29:26.329 UTC] [D] OFSCtrl battery ctrl val:0.600000
[2026-08-08 20:29:26.329 UTC] [V] 485ChCtl <C3> battery send request.1
[2026-08-08 20:29:26.330 UTC] [D] VarInf Limit_Bat rt[2]set val[3] set rate[0.600000] value100[500] value-100[-500]
[2026-08-08 20:29:26.331 UTC] [D] 485AcReq <C3:01> PutOStream [6][0f000001000000090110278e0001020003]
[2026-08-08 20:29:26.333 UTC] [V] 485ChCtl <C3> battery limit on [3.000000,] request.
[2026-08-08 20:29:26.333 UTC] [V] OFSCtrl Control charge discharge proc:01->02->BATT_CHK->03->04->05->06->07->10->11->20->21->22->23->24->25->27->28->29->30->31->32->33->34
[2026-08-08 20:29:26.427 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:26.427 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:26.477 UTC] [V] 485DevCtl <C3:01> AnalyzeResponseData proc restart cnt:360485 UPRstat:0
[2026-08-08 20:29:26.480 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-08 20:29:26.480 UTC] [D] 485DevCtl <C3:01> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-08 20:29:26.481 UTC] [D] 485DevCtl <C3:01> ResCnd OperationId [6] IsNormal[1] 
[2026-08-08 20:29:26.481 UTC] [V] 485DevCtl <C3:01> device_type:Battery
[2026-08-08 20:29:26.481 UTC] [V] 485ChCtl <C3> set rt:0
[2026-08-08 20:29:26.528 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:26.528 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:26.607 UTC] [V] 485ChCtl <C2> set rt:0
[2026-08-08 20:29:26.628 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:26.628 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:26.679 UTC] [V] OFSCtrl [/var/local/solajithome/function/output_fluctuation_suppression/batt_data] write success.
[2026-08-08 20:29:26.728 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:26.728 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:26.828 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:26.828 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:26.928 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:26.928 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:27.027 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:27.028 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:27.127 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:27.128 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:27.227 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:27.228 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:27.327 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:27.327 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:27.328 UTC] [V] OFSCtrl Control charge discharge proc start.
[2026-08-08 20:29:27.328 UTC] [V] OFSCtrl CHG 20 p_th(t):-1109.900000 = p_th_old_:-1100.000000 + lev_cd_:-0.300000 * (total_pcs_capacity_:99000.000000 * cof_spec_:2.000000 / 60 * (time_threshold_renew:10.000000 * 10)), min:-1100.000000, max:119300.000000
[2026-08-08 20:29:27.328 UTC] [V] OFSCtrl CHG 21 batt_w:285.682026 = old:289.119526 +  kp:0.550000 * e:-6.250000 + ki:0.000000 * sume:9163111.950228 + kd:0.040000 * (e:-6.250000 - e1:-6.250000)
[2026-08-08 20:29:27.329 UTC] [V] OFSCtrl CHG 29 q:2.000000, mod(round):1.000000
[2026-08-08 20:29:27.329 UTC] [D] OFSCtrl battery ctrl val:0.600000
[2026-08-08 20:29:27.329 UTC] [V] 485ChCtl <C3> battery limit on [3.000000,] request.
[2026-08-08 20:29:27.329 UTC] [V] OFSCtrl Control charge discharge proc:01->02->BATT_CHK->03->04->05->06->07->10->11->20->21->22->23->24->25->27->28->29->30->31->32->33->34
[2026-08-08 20:29:27.329 UTC] [V] 485ChCtl <C3> battery send request.1
[2026-08-08 20:29:27.330 UTC] [D] VarInf Limit_Bat rt[2]set val[3] set rate[0.600000] value100[500] value-100[-500]
[2026-08-08 20:29:27.331 UTC] [D] 485AcReq <C3:01> PutOStream [6][0f000001000000090110278e0001020003]
[2026-08-08 20:29:27.428 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:27.428 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:27.487 UTC] [V] 485DevCtl <C3:01> AnalyzeResponseData proc restart cnt:360486 UPRstat:0
[2026-08-08 20:29:27.489 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-08 20:29:27.490 UTC] [D] 485DevCtl <C3:01> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-08 20:29:27.491 UTC] [D] 485DevCtl <C3:01> ResCnd OperationId [6] IsNormal[1] 
[2026-08-08 20:29:27.491 UTC] [V] 485DevCtl <C3:01> device_type:Battery
[2026-08-08 20:29:27.491 UTC] [V] 485ChCtl <C3> set rt:0
[2026-08-08 20:29:27.528 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:27.528 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:27.628 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:27.628 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:27.679 UTC] [V] OFSCtrl [/var/local/solajithome/function/output_fluctuation_suppression/batt_data] write success.
[2026-08-08 20:29:27.728 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:27.728 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:27.827 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:27.828 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:27.927 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:27.928 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:28.027 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:28.028 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:28.127 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:28.128 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:28.227 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:28.228 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:28.327 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:28.328 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:28.328 UTC] [V] OFSCtrl Control charge discharge proc start.
[2026-08-08 20:29:28.328 UTC] [V] OFSCtrl CHG 20 p_th(t):-1109.900000 = p_th_old_:-1100.000000 + lev_cd_:-0.300000 * (total_pcs_capacity_:99000.000000 * cof_spec_:2.000000 / 60 * (time_threshold_renew:10.000000 * 10)), min:-1100.000000, max:119300.000000
[2026-08-08 20:29:28.328 UTC] [V] OFSCtrl CHG 21 batt_w:282.244526 = old:285.682026 +  kp:0.550000 * e:-6.250000 + ki:0.000000 * sume:9163105.700228 + kd:0.040000 * (e:-6.250000 - e1:-6.250000)
[2026-08-08 20:29:28.329 UTC] [V] OFSCtrl CHG 29 q:2.000000, mod(round):1.000000
[2026-08-08 20:29:28.329 UTC] [D] OFSCtrl battery ctrl val:0.600000
[2026-08-08 20:29:28.329 UTC] [V] 485ChCtl <C3> battery limit on [3.000000,] request.
[2026-08-08 20:29:28.329 UTC] [V] OFSCtrl Control charge discharge proc:01->02->BATT_CHK->03->04->05->06->07->10->11->20->21->22->23->24->25->27->28->29->30->31->32->33->34
[2026-08-08 20:29:28.329 UTC] [V] 485ChCtl <C3> battery send request.1
[2026-08-08 20:29:28.330 UTC] [D] VarInf Limit_Bat rt[2]set val[3] set rate[0.600000] value100[500] value-100[-500]
[2026-08-08 20:29:28.331 UTC] [D] 485AcReq <C3:01> PutOStream [6][0f000001000000090110278e0001020003]
[2026-08-08 20:29:28.428 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:28.428 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:28.487 UTC] [V] 485DevCtl <C3:01> AnalyzeResponseData proc restart cnt:360487 UPRstat:0
[2026-08-08 20:29:28.490 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-08 20:29:28.491 UTC] [D] 485DevCtl <C3:01> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-08 20:29:28.491 UTC] [D] 485DevCtl <C3:01> ResCnd OperationId [6] IsNormal[1] 
[2026-08-08 20:29:28.491 UTC] [V] 485DevCtl <C3:01> device_type:Battery
[2026-08-08 20:29:28.491 UTC] [V] 485ChCtl <C3> set rt:0
[2026-08-08 20:29:28.528 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:28.528 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:28.627 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:28.628 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:28.679 UTC] [V] OFSCtrl [/var/local/solajithome/function/output_fluctuation_suppression/batt_data] write success.
[2026-08-08 20:29:28.727 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:28.728 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:28.827 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:28.828 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:28.928 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:28.928 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:29.028 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:29.028 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:29.128 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:29.128 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:29.228 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:29.228 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:29.327 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:29.328 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:29.328 UTC] [V] OFSCtrl Control charge discharge proc start.
[2026-08-08 20:29:29.328 UTC] [V] OFSCtrl CHG 20 p_th(t):-1109.900000 = p_th_old_:-1100.000000 + lev_cd_:-0.300000 * (total_pcs_capacity_:99000.000000 * cof_spec_:2.000000 / 60 * (time_threshold_renew:10.000000 * 10)), min:-1100.000000, max:119300.000000
[2026-08-08 20:29:29.328 UTC] [V] OFSCtrl CHG 21 batt_w:278.807026 = old:282.244526 +  kp:0.550000 * e:-6.250000 + ki:0.000000 * sume:9163099.450228 + kd:0.040000 * (e:-6.250000 - e1:-6.250000)
[2026-08-08 20:29:29.329 UTC] [V] OFSCtrl CHG 29 q:2.000000, mod(round):1.000000
[2026-08-08 20:29:29.329 UTC] [D] OFSCtrl battery ctrl val:0.600000
[2026-08-08 20:29:29.329 UTC] [V] 485ChCtl <C3> battery limit on [3.000000,] request.
[2026-08-08 20:29:29.329 UTC] [V] OFSCtrl Control charge discharge proc:01->02->BATT_CHK->03->04->05->06->07->10->11->20->21->22->23->24->25->27->28->29->30->31->32->33->34
[2026-08-08 20:29:29.329 UTC] [V] 485ChCtl <C3> battery send request.1
[2026-08-08 20:29:29.330 UTC] [D] VarInf Limit_Bat rt[2]set val[3] set rate[0.600000] value100[500] value-100[-500]
[2026-08-08 20:29:29.331 UTC] [D] 485AcReq <C3:01> PutOStream [6][0f000001000000090110278e0001020003]
[2026-08-08 20:29:29.409 UTC] [V] 485ChCtl <C2> StartDeviceCommunicationForOutputFluctuationSuppressionControlBroadcast 4 cnt:3604940, monitor_cnt:50, bc_elapsed:3604940, min:10, max:40
[2026-08-08 20:29:29.410 UTC] [V] OFSCtrl /var/local/solajithome/function/output_fluctuation_suppression/state is exist:0
[2026-08-08 20:29:29.410 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :9
[2026-08-08 20:29:29.411 UTC] [V] 485ChCtl <C2> send request:Sungrow08
[2026-08-08 20:29:29.412 UTC] [D] 485AcReq <C2:01> PutOStream [9][0800010413fa001794b1]
[2026-08-08 20:29:29.428 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:29.428 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:29.477 UTC] [V] 485DevCtl <C3:01> AnalyzeResponseData proc restart cnt:360488 UPRstat:0
[2026-08-08 20:29:29.480 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-08 20:29:29.481 UTC] [D] 485DevCtl <C3:01> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-08 20:29:29.481 UTC] [D] 485DevCtl <C3:01> ResCnd OperationId [6] IsNormal[1] 
[2026-08-08 20:29:29.481 UTC] [V] 485DevCtl <C3:01> device_type:Battery
[2026-08-08 20:29:29.481 UTC] [V] 485ChCtl <C3> set rt:0
[2026-08-08 20:29:29.528 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:29.528 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:29.628 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:29.628 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:29.679 UTC] [V] OFSCtrl [/var/local/solajithome/function/output_fluctuation_suppression/batt_data] write success.
[2026-08-08 20:29:29.728 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:29.728 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:29.782 UTC] [V] Res no response condition. set normal condition.
[2026-08-08 20:29:29.783 UTC] [D] 485DevCtl <C2:01> RcvDat status[2] len[51] [01042e000000000000000000000000ffffffffffffffff03e8ffffffff41060000ffffffffffffffffffffffffffffffff406b]
[2026-08-08 20:29:29.783 UTC] [D] 485DevCtl <C2:01> ResCnd OperationId [9] IsNormal[1] 
[2026-08-08 20:29:29.784 UTC] [V] 485DevCtl <C2:01> [04][101100][0.000000][1][V]
[2026-08-08 20:29:29.784 UTC] [V] SummDat SetVrmValue dev_id:7 val:0.000000 sc:3
[2026-08-08 20:29:29.784 UTC] [V] OCMgr SetMeterValue PhId:0201, branchNo:04, valueId:101100, value:0.000000, scaleFactor:1, devId:7
[2026-08-08 20:29:29.785 UTC] [V] 485DevCtl <C2:01> [04][101101][0.000000][1][A]
[2026-08-08 20:29:29.785 UTC] [V] SummDat SetVrmValue dev_id:7 val:0.000000 sc:3
[2026-08-08 20:29:29.785 UTC] [V] OCMgr SetMeterValue PhId:0201, branchNo:04, valueId:101101, value:0.000000, scaleFactor:1, devId:7
[2026-08-08 20:29:29.799 UTC] [V] 485DevCtl <C2:01> [05][101100][0.000000][1][V]
[2026-08-08 20:29:29.807 UTC] [V] SummDat SetVrmValue dev_id:7 val:0.000000 sc:3
[2026-08-08 20:29:29.817 UTC] [V] OCMgr SetMeterValue PhId:0201, branchNo:05, valueId:101100, value:0.000000, scaleFactor:1, devId:7
[2026-08-08 20:29:29.819 UTC] [V] 485DevCtl <C2:01> [05][101101][0.000000][1][A]
[2026-08-08 20:29:29.821 UTC] [V] SummDat SetVrmValue dev_id:7 val:0.000000 sc:3
[2026-08-08 20:29:29.825 UTC] [V] OCMgr SetMeterValue PhId:0201, branchNo:05, valueId:101101, value:0.000000, scaleFactor:1, devId:7
[2026-08-08 20:29:29.827 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:29.828 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:29.828 UTC] [V] 485DevCtl <C2:01> [06][101100][0.000000][1][V]
[2026-08-08 20:29:29.830 UTC] [V] SummDat SetVrmValue dev_id:7 val:0.000000 sc:3
[2026-08-08 20:29:29.834 UTC] [V] OCMgr SetMeterValue PhId:0201, branchNo:06, valueId:101100, value:0.000000, scaleFactor:1, devId:7
[2026-08-08 20:29:29.837 UTC] [V] 485DevCtl <C2:01> [06][101101][0.000000][1][A]
[2026-08-08 20:29:29.839 UTC] [V] SummDat SetVrmValue dev_id:7 val:0.000000 sc:3
[2026-08-08 20:29:29.843 UTC] [V] OCMgr SetMeterValue PhId:0201, branchNo:06, valueId:101101, value:0.000000, scaleFactor:1, devId:7
[2026-08-08 20:29:29.856 UTC] [V] 485DevCtl <C2:01> device_type:PV-PCS
[2026-08-08 20:29:29.867 UTC] [V] 485ChCtl <C2> set rt:0
[2026-08-08 20:29:29.909 UTC] [V] 485ChCtl <C2> StartDeviceCommunicationForOutputFluctuationSuppressionControlBroadcast 4 cnt:3604945, monitor_cnt:55, bc_elapsed:3604945, min:10, max:40
[2026-08-08 20:29:29.909 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :4
[2026-08-08 20:29:29.910 UTC] [V] 485ChCtl <C2> send request:Sungrow08
[2026-08-08 20:29:29.911 UTC] [D] 485AcReq <C2:02> PutOStream [4][0800020413b40001755b]
[2026-08-08 20:29:29.927 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:29.927 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:30.027 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:30.028 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:30.128 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:30.128 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:30.227 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:30.228 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:30.252 UTC] [D] 485DevCtl <C2:02> RcvDat status[2] len[7] [0204020000fd30]
[2026-08-08 20:29:30.253 UTC] [D] 485DevCtl <C2:02> ResCnd OperationId [4] IsNormal[0]  ConditionType [lggrdev:Error] Action[-1]
[2026-08-08 20:29:30.259 UTC] [V] 485DevCtl <C2:02> device_type:PV-PCS
[2026-08-08 20:29:30.268 UTC] [V] 485ChCtl <C2> set rt:0
[2026-08-08 20:29:30.270 UTC] [D] 485ChCtl <C2> monitoring dev All Send
[2026-08-08 20:29:30.328 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:30.328 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:30.328 UTC] [V] OFSCtrl Control charge discharge proc start.
[2026-08-08 20:29:30.329 UTC] [V] OFSCtrl CHG 20 p_th(t):-1109.900000 = p_th_old_:-1100.000000 + lev_cd_:-0.300000 * (total_pcs_capacity_:99000.000000 * cof_spec_:2.000000 / 60 * (time_threshold_renew:10.000000 * 10)), min:-1100.000000, max:119300.000000
[2026-08-08 20:29:30.329 UTC] [V] OFSCtrl CHG 21 batt_w:275.369526 = old:278.807026 +  kp:0.550000 * e:-6.250000 + ki:0.000000 * sume:9163093.200228 + kd:0.040000 * (e:-6.250000 - e1:-6.250000)
[2026-08-08 20:29:30.329 UTC] [V] OFSCtrl CHG 29 q:2.000000, mod(round):1.000000
[2026-08-08 20:29:30.329 UTC] [D] OFSCtrl battery ctrl val:0.600000
[2026-08-08 20:29:30.329 UTC] [V] 485ChCtl <C3> battery limit on [3.000000,] request.
[2026-08-08 20:29:30.330 UTC] [V] OFSCtrl Control charge discharge proc:01->02->BATT_CHK->03->04->05->06->07->10->11->20->21->22->23->24->25->27->28->29->30->31->32->33->34
[2026-08-08 20:29:30.330 UTC] [V] 485ChCtl <C3> battery send request.1
[2026-08-08 20:29:30.330 UTC] [D] VarInf Limit_Bat rt[2]set val[3] set rate[0.600000] value100[500] value-100[-500]
[2026-08-08 20:29:30.332 UTC] [D] 485AcReq <C3:01> PutOStream [6][0f000001000000090110278e0001020003]
[2026-08-08 20:29:30.393 UTC] [V] 485DevCtl <C1:01> device_type:Irr-Meter
[2026-08-08 20:29:30.393 UTC] [V] 485DevCtl <C1:01> device_type:Irr-Meter
[2026-08-08 20:29:30.393 UTC] [V] 485ChCtl <C1> fixed cycle Irr-Meter
[2026-08-08 20:29:30.393 UTC] [V] 485DevCtl <C1:01> Dev not PCS IsNeedToChangeOControlState
[2026-08-08 20:29:30.394 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :1
[2026-08-08 20:29:30.394 UTC] [V] 485ChCtl <C1> send request:Irr01
[2026-08-08 20:29:30.395 UTC] [D] 485AcReq <C1:01> PutOStream [1][080001040000000271cb]
[2026-08-08 20:29:30.427 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:30.428 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:30.487 UTC] [V] 485DevCtl <C3:01> AnalyzeResponseData proc restart cnt:360489 UPRstat:0
[2026-08-08 20:29:30.490 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-08 20:29:30.491 UTC] [D] 485DevCtl <C3:01> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-08 20:29:30.491 UTC] [D] 485DevCtl <C3:01> ResCnd OperationId [6] IsNormal[1] 
[2026-08-08 20:29:30.491 UTC] [V] 485DevCtl <C3:01> device_type:Battery
[2026-08-08 20:29:30.491 UTC] [V] 485ChCtl <C3> set rt:0
[2026-08-08 20:29:30.527 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:30.528 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:30.627 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:30.627 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:30.679 UTC] [V] OFSCtrl [/var/local/solajithome/function/output_fluctuation_suppression/batt_data] write success.
[2026-08-08 20:29:30.721 UTC] [V] 485DevCtl <C1:01> AnalyzeResponseData proc restart cnt:360491 UPRstat:0
[2026-08-08 20:29:30.722 UTC] [V] Res no response condition. set normal condition.
[2026-08-08 20:29:30.722 UTC] [D] 485DevCtl <C1:01> RcvDat status[2] len[9] [010404000002013b24]
[2026-08-08 20:29:30.722 UTC] [D] 485DevCtl <C1:01> ResCnd OperationId [1] IsNormal[1] 
[2026-08-08 20:29:30.723 UTC] [V] OFSCtrl Rcv set flux_of_solar:0.000000
[2026-08-08 20:29:30.723 UTC] [V] 485DevCtl <C1:01> [01][401006][0.000000][1][W/m2]
[2026-08-08 20:29:30.723 UTC] [V] SummDat SetVrmValue dev_id:1 val:0.000000 sc:3
[2026-08-08 20:29:30.723 UTC] [V] OCMgr SetMeterValue PhId:0101, branchNo:01, valueId:401006, value:0.000000, scaleFactor:1, devId:1
[2026-08-08 20:29:30.724 UTC] [V] 485DevCtl <C1:01> [01][421005][263.000000][1][℃]
[2026-08-08 20:29:30.724 UTC] [V] SummDat SetVrmValue dev_id:1 val:26300.000000 sc:3
[2026-08-08 20:29:30.724 UTC] [V] OCMgr SetMeterValue PhId:0101, branchNo:01, valueId:421005, value:263.000000, scaleFactor:1, devId:1
[2026-08-08 20:29:30.724 UTC] [V] 485DevCtl <C1:01> device_type:Irr-Meter
[2026-08-08 20:29:30.724 UTC] [V] OFSCtrl Irr-Meter received.
[2026-08-08 20:29:30.727 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:30.727 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:30.730 UTC] [V] 485ChCtl <C3> StartDeviceCommunicationForOutputFluctuationSuppressionControlBroadcast 4 cnt:3604953, monitor_cnt:50, bc_elapsed:3604953, min:10, max:40
[2026-08-08 20:29:30.730 UTC] [V] OFSCtrl /var/local/solajithome/function/output_fluctuation_suppression/state is exist:0
[2026-08-08 20:29:30.730 UTC] [V] 485DevCtl <C3:01> Dev not PCS IsNeedToChangeOControlState
[2026-08-08 20:29:30.730 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :3
[2026-08-08 20:29:30.731 UTC] [V] 485ChCtl <C3> send request:Sungrow11
[2026-08-08 20:29:30.732 UTC] [D] 485AcReq <C3:01> PutOStream [3][0c00000100000006010435260018]
[2026-08-08 20:29:30.734 UTC] [V] 485ChCtl <C1> set rt:0
[2026-08-08 20:29:30.738 UTC] [V] 485DevCtl <C1:01> device_type:Irr-Meter
[2026-08-08 20:29:30.794 UTC] [V] 485DevCtl <C1:04> device_type:CO-Meter
[2026-08-08 20:29:30.794 UTC] [V] 485DevCtl <C1:04> device_type:CO-Meter
[2026-08-08 20:29:30.795 UTC] [V] 485ChCtl <C1> fixed cycle CO-Meter
[2026-08-08 20:29:30.795 UTC] [V] 485DevCtl <C1:04> Dev not PCS IsNeedToChangeOControlState
[2026-08-08 20:29:30.795 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :1
[2026-08-08 20:29:30.796 UTC] [V] 485ChCtl <C1> send request:omron05
[2026-08-08 20:29:30.796 UTC] [D] 485AcReq <C1:04> PutOStream [1][0800040300030014b590]
[2026-08-08 20:29:30.828 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:30.828 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:30.867 UTC] [V] 485DevCtl <C3:01> AnalyzeResponseData proc restart cnt:360490 UPRstat:0
[2026-08-08 20:29:30.873 UTC] [D] 485DevCtl <C3:01> RcvDat status[0] len[57] [0001000000330104301e3e0000006e03e81e3e006e00010001ffff0100ffff013b013bffff008c008c00640064ffff7e367b70012c011d02c5]
[2026-08-08 20:29:30.873 UTC] [D] 485DevCtl <C3:01> ResCnd OperationId [3] IsNormal[1]  ConditionType [lggrdev:Normal] Action[-1]
[2026-08-08 20:29:30.876 UTC] [V] 485DevCtl <C3:01> [01][721100][7742.000000][1][V]
[2026-08-08 20:29:30.878 UTC] [V] SummDat SetVrmValue dev_id:9 val:774200.000000 sc:3
[2026-08-08 20:29:30.883 UTC] [V] OCMgr SetMeterValue PhId:0301, branchNo:01, valueId:721100, value:7742.000000, scaleFactor:1, devId:9
[2026-08-08 20:29:30.887 UTC] [V] 485DevCtl <C3:01> [01][721101][0.000000][1][A]
[2026-08-08 20:29:30.888 UTC] [V] SummDat SetVrmValue dev_id:9 val:0.000000 sc:3
[2026-08-08 20:29:30.893 UTC] [V] OCMgr SetMeterValue PhId:0301, branchNo:01, valueId:721101, value:0.000000, scaleFactor:1, devId:9
[2026-08-08 20:29:30.897 UTC] [V] OFSCtrl change set SOC(t):11.000000 drive cnt:1
[2026-08-08 20:29:30.899 UTC] [V] OFSCtrl Rcv set soc[0301]:11.000000
[2026-08-08 20:29:30.900 UTC] [V] 485DevCtl <C3:01> [01][721035][110.000000][1][%]
[2026-08-08 20:29:30.903 UTC] [V] SummDat SetVrmValue dev_id:9 val:11000.000000 sc:3
[2026-08-08 20:29:30.907 UTC] [V] OCMgr SetMeterValue PhId:0301, branchNo:01, valueId:721035, value:110.000000, scaleFactor:1, devId:9
[2026-08-08 20:29:30.909 UTC] [V] 485DevCtl <C3:01> [01][721036][1000.000000][1][%]
[2026-08-08 20:29:30.910 UTC] [V] SummDat SetVrmValue dev_id:9 val:100000.000000 sc:3
[2026-08-08 20:29:30.912 UTC] [V] OCMgr SetMeterValue PhId:0301, branchNo:01, valueId:721036, value:1000.000000, scaleFactor:1, devId:9
[2026-08-08 20:29:30.916 UTC] [V] 485DevCtl <C3:01> [01][721030][32310.000000][4][V]
[2026-08-08 20:29:30.918 UTC] [V] SummDat SetVrmValue dev_id:9 val:3231.000000 sc:3
[2026-08-08 20:29:30.921 UTC] [V] OCMgr SetMeterValue PhId:0301, branchNo:01, valueId:721030, value:32310.000000, scaleFactor:4, devId:9
[2026-08-08 20:29:30.925 UTC] [V] 485DevCtl <C3:01> [01][721031][31600.000000][4][V]
[2026-08-08 20:29:30.926 UTC] [V] SummDat SetVrmValue dev_id:9 val:3160.000000 sc:3
[2026-08-08 20:29:30.926 UTC] [V] OCMgr SetMeterValue PhId:0301, branchNo:01, valueId:721031, value:31600.000000, scaleFactor:4, devId:9
[2026-08-08 20:29:30.926 UTC] [V] 485DevCtl <C3:01> [01][721032][300.000000][1][℃]
[2026-08-08 20:29:30.926 UTC] [V] SummDat SetVrmValue dev_id:9 val:30000.000000 sc:3
[2026-08-08 20:29:30.926 UTC] [V] OCMgr SetMeterValue PhId:0301, branchNo:01, valueId:721032, value:300.000000, scaleFactor:1, devId:9
[2026-08-08 20:29:30.927 UTC] [V] 485DevCtl <C3:01> [01][721033][285.000000][1][℃]
[2026-08-08 20:29:30.927 UTC] [V] SummDat SetVrmValue dev_id:9 val:28500.000000 sc:3
[2026-08-08 20:29:30.927 UTC] [V] OCMgr SetMeterValue PhId:0301, branchNo:01, valueId:721033, value:285.000000, scaleFactor:1, devId:9
[2026-08-08 20:29:30.928 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:30.928 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:30.936 UTC] [V] 485DevCtl <C3:01> device_type:Battery
[2026-08-08 20:29:30.947 UTC] [V] 485ChCtl <C3> set rt:0
[2026-08-08 20:29:30.949 UTC] [D] 485ChCtl <C3> monitoring dev All Send
[2026-08-08 20:29:31.028 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:31.028 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:31.128 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:31.128 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:31.204 UTC] [V] 485DevCtl <C1:04> AnalyzeResponseData proc restart cnt:360490 UPRstat:0
[2026-08-08 20:29:31.204 UTC] [V] Res no response condition. set normal condition.
[2026-08-08 20:29:31.206 UTC] [D] 485DevCtl <C1:04> RcvDat status[2] len[45] [04032800002226000017ff000017eaffffffe500000258ffffe8d4ffffffc5ffffaf58ffffff3200121a8127d3]
[2026-08-08 20:29:31.206 UTC] [D] 485DevCtl <C1:04> ResCnd OperationId [1] IsNormal[1] 
[2026-08-08 20:29:31.206 UTC] [V] OFSCtrl Rcv set p_co:-590.000000, p_co_old:-590.000000
[2026-08-08 20:29:31.207 UTC] [V] 485DevCtl <C1:04> [01][601260][-59.000000][2][kW]
[2026-08-08 20:29:31.207 UTC] [V] SummDat SetVrmValue dev_id:4 val:-590.000000 sc:3
[2026-08-08 20:29:31.212 UTC] [V] OCMgr SetMeterValue PhId:0104, branchNo:01, valueId:601260, value:-59.000000, scaleFactor:2, devId:4
[2026-08-08 20:29:31.212 UTC] [V] 485DevCtl <C1:04> [01][603260][1186433.000000][1][kWh]
[2026-08-08 20:29:31.212 UTC] [V] SummDat SetVrmValue dev_id:4 val:1186433.000000 sc:1
[2026-08-08 20:29:31.212 UTC] [V] OCMgr SetMeterValue PhId:0104, branchNo:01, valueId:603260, value:1186433.000000, scaleFactor:1, devId:4
[2026-08-08 20:29:31.213 UTC] [V] 485DevCtl <C1:04> device_type:CO-Meter
[2026-08-08 20:29:31.213 UTC] [V] OFSCtrl km50 received.
[2026-08-08 20:29:31.213 UTC] [V] OFSCtrl omron05_local_date :2026/08/09 ? 2026/08/09
[2026-08-08 20:29:31.213 UTC] [V] OFSCtrl omron05_local_time :2026/08/09 05 ? 2026/08/09 05
[2026-08-08 20:29:31.213 UTC] [V] OFSCtrl out of control time.
[2026-08-08 20:29:31.213 UTC] [V] OFSCtrl Control pv-pcs proc start.
[2026-08-08 20:29:31.214 UTC] [V] OFSCtrl NOD_month:-1664.000000 = (NOD_month:306 - ((nod_max_/30):23.333333 * (cnt-1):25) * (30/cnt):6.000000 
[2026-08-08 20:29:31.214 UTC] [V] OFSCtrl PCS ratio_month:232.646617 = -k_inhibition_ratio_month:-0.097744 * NOD_month:-1664.000000 + inhibition_ratio_max:70
[2026-08-08 20:29:31.214 UTC] [V] OFSCtrl PCS 05 inhibition_ratio:70.000000 = max(ratio_min:5, min(ratio:70, ratio_hour:70.000000, ratio_day:70.000000, ratio_month:232.646617))
[2026-08-08 20:29:31.214 UTC] [D] OFSCtrl pv-pcs ctrl val:0.000000 old:0.000000
[2026-08-08 20:29:31.214 UTC] [V] OCHisDB set rate:0 t_rate:0 cnt:53
[2026-08-08 20:29:31.215 UTC] [V] 485ChCtl <C2> pv-pcs limit on [0.000000] request.
[2026-08-08 20:29:31.215 UTC] [V] OFSCtrl Control pv-pcs proc:BATT_CHK->01->02->03->04->05->06->07->09->09->10->11->12
[2026-08-08 20:29:31.215 UTC] [V] OFSCtrl Nod calc proc start.
[2026-08-08 20:29:31.215 UTC] [V] OFSCtrl ProcNodCountCalculation culc nod skip stop:0, pause:0, ctl_time:0
[2026-08-08 20:29:31.215 UTC] [V] OFSCtrl update p_co_old:-590.000000
[2026-08-08 20:29:31.215 UTC] [V] OFSCtrl Nod calc proc:
[2026-08-08 20:29:31.228 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:31.228 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:31.254 UTC] [V] 485ChCtl <C1> set rt:0
[2026-08-08 20:29:31.256 UTC] [V] 485DevCtl <C1:04> device_type:CO-Meter
[2026-08-08 20:29:31.309 UTC] [V] 485ChCtl <C2> pv-pcs send request.
[2026-08-08 20:29:31.310 UTC] [D] VarInf update ofs_rate:0.000000
[2026-08-08 20:29:31.310 UTC] [V] VarInf LimitSet rt[2] val[170] key[ValueOn]
[2026-08-08 20:29:31.310 UTC] [D] VarInf output_mode:8
[2026-08-08 20:29:31.310 UTC] [D] VarInf update ofs_rate:0.000000
[2026-08-08 20:29:31.310 UTC] [D] VarInf Limit setRate[0.000000] rate[0.000000] value100[1000.000000] value0[0.000000]
[2026-08-08 20:29:31.310 UTC] [V] 485DevCtl <C2:01> ChangeOutputRateToDevice rate:0.000000 set_rate1
[2026-08-08 20:29:31.310 UTC] [D] VarInf Limit rt[2] int_set_rate[1] server_rate[0.000000] rated_output[100.000000] solar_battery_power[100.000000]
[2026-08-08 20:29:31.312 UTC] [D] 485AcReq <C2:01> PutOStreamForBc [3][0d000010138e00020400aa0001466f]
[2026-08-08 20:29:31.328 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:31.328 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:31.328 UTC] [V] OFSCtrl Control charge discharge proc start.
[2026-08-08 20:29:31.328 UTC] [V] OFSCtrl CHG 20 p_th(t):-1109.900000 = p_th_old_:-1100.000000 + lev_cd_:-0.300000 * (total_pcs_capacity_:99000.000000 * cof_spec_:2.000000 / 60 * (time_threshold_renew:10.000000 * 10)), min:-1100.000000, max:119300.000000
[2026-08-08 20:29:31.329 UTC] [V] OFSCtrl CHG 21 batt_w:271.932026 = old:275.369526 +  kp:0.550000 * e:-6.250000 + ki:0.000000 * sume:9163086.950228 + kd:0.040000 * (e:-6.250000 - e1:-6.250000)
[2026-08-08 20:29:31.329 UTC] [V] OFSCtrl CHG 29 q:2.000000, mod(round):1.000000
[2026-08-08 20:29:31.329 UTC] [D] OFSCtrl battery ctrl val:0.500000
[2026-08-08 20:29:31.329 UTC] [V] 485ChCtl <C3> battery limit on [3.000000,] request.
[2026-08-08 20:29:31.329 UTC] [V] OFSCtrl Control charge discharge proc:01->02->BATT_CHK->03->04->05->06->07->10->11->20->21->22->23->24->25->27->28->29->30->31->32->33->34
[2026-08-08 20:29:31.330 UTC] [V] 485ChCtl <C3> battery send request.1
[2026-08-08 20:29:31.330 UTC] [D] VarInf Limit_Bat rt[2]set val[3] set rate[0.600000] value100[500] value-100[-500]
[2026-08-08 20:29:31.332 UTC] [D] 485AcReq <C3:01> PutOStream [6][0f000001000000090110278e0001020003]
[2026-08-08 20:29:31.428 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:31.428 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:31.477 UTC] [V] 485DevCtl <C3:01> AnalyzeResponseData proc restart cnt:360490 UPRstat:0
[2026-08-08 20:29:31.479 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-08 20:29:31.480 UTC] [D] 485DevCtl <C3:01> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-08 20:29:31.480 UTC] [D] 485DevCtl <C3:01> ResCnd OperationId [6] IsNormal[1] 
[2026-08-08 20:29:31.480 UTC] [V] 485DevCtl <C3:01> device_type:Battery
[2026-08-08 20:29:31.480 UTC] [V] 485ChCtl <C3> set rt:0
[2026-08-08 20:29:31.493 UTC] [V] 485ChCtl <C1> StartDeviceCommunicationForOutputFluctuationSuppressionControlBroadcast 4 cnt:3604961, monitor_cnt:100, bc_elapsed:11, min:10, max:40
[2026-08-08 20:29:31.493 UTC] [V] OFSCtrl /var/local/solajithome/function/output_fluctuation_suppression/state is exist:0
[2026-08-08 20:29:31.528 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:31.528 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:31.593 UTC] [V] 485ChCtl <C1> StartDeviceCommunicationForOutputFluctuationSuppressionControlBroadcast 4 cnt:3604962, monitor_cnt:101, bc_elapsed:12, min:10, max:40
[2026-08-08 20:29:31.593 UTC] [V] 485DevCtl <C1:02> Dev not PCS IsNeedToChangeOControlState
[2026-08-08 20:29:31.593 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :1
[2026-08-08 20:29:31.594 UTC] [V] 485ChCtl <C1> send request:IMT01
[2026-08-08 20:29:31.594 UTC] [D] 485AcReq <C1:02> PutOStream [1][08000204000200019039]
[2026-08-08 20:29:31.601 UTC] [V] 485ChCtl <C2> set rt:0
[2026-08-08 20:29:31.628 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:31.628 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:31.679 UTC] [V] OFSCtrl [/var/local/solajithome/function/output_fluctuation_suppression/batt_data] write success.
[2026-08-08 20:29:31.727 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:31.728 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:31.827 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:31.828 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:31.928 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:31.928 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:31.933 UTC] [V] 485DevCtl <C1:02> AnalyzeResponseData proc restart cnt:360485 UPRstat:0
[2026-08-08 20:29:31.933 UTC] [V] Res no response condition. set normal condition.
[2026-08-08 20:29:31.934 UTC] [D] 485DevCtl <C1:02> RcvDat status[2] len[7] [02040202067c52]
[2026-08-08 20:29:31.934 UTC] [D] 485DevCtl <C1:02> ResCnd OperationId [1] IsNormal[1] 
[2026-08-08 20:29:31.934 UTC] [V] 485DevCtl <C1:02> [01][431005][268.000000][1][°C]
[2026-08-08 20:29:31.935 UTC] [V] SummDat SetVrmValue dev_id:2 val:26800.000000 sc:3
[2026-08-08 20:29:31.935 UTC] [V] OCMgr SetMeterValue PhId:0102, branchNo:01, valueId:431005, value:268.000000, scaleFactor:1, devId:2
[2026-08-08 20:29:31.935 UTC] [V] 485DevCtl <C1:02> device_type:
[2026-08-08 20:29:31.940 UTC] [V] 485ChCtl <C1> set rt:0
[2026-08-08 20:29:31.993 UTC] [V] 485ChCtl <C1> StartDeviceCommunicationForOutputFluctuationSuppressionControlBroadcast 4 cnt:3604966, monitor_cnt:105, bc_elapsed:16, min:10, max:40
[2026-08-08 20:29:31.993 UTC] [V] 485DevCtl <C1:03> Dev not PCS IsNeedToChangeOControlState
[2026-08-08 20:29:31.993 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :2
[2026-08-08 20:29:31.994 UTC] [V] 485ChCtl <C1> send request:omron03
[2026-08-08 20:29:31.995 UTC] [D] 485AcReq <C1:03> PutOStream [2][08000303002000084424]
[2026-08-08 20:29:32.027 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:32.028 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:32.128 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:32.128 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:32.228 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:32.228 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:32.328 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:32.328 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:32.328 UTC] [V] OFSCtrl Control charge discharge proc start.
[2026-08-08 20:29:32.328 UTC] [V] OFSCtrl CHG 20 p_th(t):-1109.900000 = p_th_old_:-1100.000000 + lev_cd_:-0.300000 * (total_pcs_capacity_:99000.000000 * cof_spec_:2.000000 / 60 * (time_threshold_renew:10.000000 * 10)), min:-1100.000000, max:119300.000000
[2026-08-08 20:29:32.329 UTC] [V] OFSCtrl CHG 21 batt_w:268.494526 = old:271.932026 +  kp:0.550000 * e:-6.250000 + ki:0.000000 * sume:9163080.700228 + kd:0.040000 * (e:-6.250000 - e1:-6.250000)
[2026-08-08 20:29:32.329 UTC] [V] OFSCtrl CHG 29 q:2.000000, mod(round):1.000000
[2026-08-08 20:29:32.330 UTC] [D] OFSCtrl battery ctrl val:0.500000
[2026-08-08 20:29:32.330 UTC] [V] 485ChCtl <C3> battery limit on [3.000000,] request.
[2026-08-08 20:29:32.331 UTC] [V] OFSCtrl Control charge discharge proc:01->02->BATT_CHK->03->04->05->06->07->10->11->20->21->22->23->24->25->27->28->29->30->31->32->33->34
[2026-08-08 20:29:32.358 UTC] [V] 485DevCtl <C1:03> AnalyzeResponseData proc restart cnt:360485 UPRstat:0
[2026-08-08 20:29:32.358 UTC] [V] Res no response condition. set normal condition.
[2026-08-08 20:29:32.359 UTC] [D] 485DevCtl <C1:03> RcvDat status[2] len[21] [0303100000000038368628000000000006843b06d2]
[2026-08-08 20:29:32.359 UTC] [D] 485DevCtl <C1:03> ResCnd OperationId [2] IsNormal[1] 
[2026-08-08 20:29:32.362 UTC] [V] StructInfo Add 943097.384000 = 0.000000+943097.384000+0.000000
[2026-08-08 20:29:32.363 UTC] [V] 485DevCtl <C1:03> [01][603202][94309738.400000][2][kWh]
[2026-08-08 20:29:32.363 UTC] [V] SummDat SetVrmValue dev_id:3 val:94309738.400000 sc:2
[2026-08-08 20:29:32.368 UTC] [V] OCMgr SetMeterValue PhId:0103, branchNo:01, valueId:603202, value:94309738.400000, scaleFactor:2, devId:3
[2026-08-08 20:29:32.371 UTC] [V] 485DevCtl <C1:03> [01][604202][94309738.400000][2][kWh]
[2026-08-08 20:29:32.377 UTC] [V] OCMgr SetMeterValue PhId:0103, branchNo:01, valueId:604202, value:94309738.400000, scaleFactor:2, devId:3
[2026-08-08 20:29:32.385 UTC] [V] StructInfo Add 427.067000 = 0.000000+427.067000+0.000000
[2026-08-08 20:29:32.389 UTC] [V] 485DevCtl <C1:03> [01][613202][42706.700000][2][kWh]
[2026-08-08 20:29:32.390 UTC] [V] SummDat SetVrmValue dev_id:3 val:42706.700000 sc:2
[2026-08-08 20:29:32.396 UTC] [V] OCMgr SetMeterValue PhId:0103, branchNo:01, valueId:613202, value:42706.700000, scaleFactor:2, devId:3
[2026-08-08 20:29:32.399 UTC] [V] 485DevCtl <C1:03> device_type:Grid-Meter
[2026-08-08 20:29:32.406 UTC] [V] 485ChCtl <C1> set rt:0
[2026-08-08 20:29:32.428 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:32.428 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:32.429 UTC] [V] 485ChCtl <C3> battery send request.1
[2026-08-08 20:29:32.430 UTC] [D] VarInf Limit_Bat rt[2]set val[3] set rate[0.600000] value100[500] value-100[-500]
[2026-08-08 20:29:32.431 UTC] [D] 485AcReq <C3:01> PutOStream [6][0f000001000000090110278e0001020003]
[2026-08-08 20:29:32.493 UTC] [V] 485ChCtl <C1> StartDeviceCommunicationForOutputFluctuationSuppressionControlBroadcast 4 cnt:3604971, monitor_cnt:110, bc_elapsed:21, min:10, max:40
[2026-08-08 20:29:32.528 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:32.528 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:32.593 UTC] [V] 485ChCtl <C1> StartDeviceCommunicationForOutputFluctuationSuppressionControlBroadcast 4 cnt:3604972, monitor_cnt:111, bc_elapsed:22, min:10, max:40
[2026-08-08 20:29:32.593 UTC] [V] 485DevCtl <C1:05> Dev not PCS IsNeedToChangeOControlState
[2026-08-08 20:29:32.593 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :1
[2026-08-08 20:29:32.594 UTC] [V] 485ChCtl <C1> send request:omron04
[2026-08-08 20:29:32.594 UTC] [D] 485AcReq <C1:05> PutOStream [1][0800050300030014b441]
[2026-08-08 20:29:32.598 UTC] [V] 485DevCtl <C3:01> AnalyzeResponseData proc restart cnt:360492 UPRstat:0
[2026-08-08 20:29:32.599 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-08 20:29:32.600 UTC] [D] 485DevCtl <C3:01> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-08 20:29:32.600 UTC] [D] 485DevCtl <C3:01> ResCnd OperationId [6] IsNormal[1] 
[2026-08-08 20:29:32.600 UTC] [V] 485DevCtl <C3:01> device_type:Battery
[2026-08-08 20:29:32.601 UTC] [V] 485ChCtl <C3> set rt:0
[2026-08-08 20:29:32.627 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:32.628 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:32.678 UTC] [V] OFSCtrl [/var/local/solajithome/function/output_fluctuation_suppression/batt_data] write success.
[2026-08-08 20:29:32.727 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:32.728 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:32.827 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:32.827 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:32.927 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:32.927 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:32.991 UTC] [V] 485DevCtl <C1:05> AnalyzeResponseData proc restart cnt:360485 UPRstat:0
[2026-08-08 20:29:32.991 UTC] [V] Res no response condition. set normal condition.
[2026-08-08 20:29:32.993 UTC] [D] 485DevCtl <C1:05> RcvDat status[2] len[45] [050328000020b3000015ba000016d7ffffffda00000258ffffdf2bffffffacffffb0f2ffffff36001385395daa]
[2026-08-08 20:29:32.993 UTC] [D] 485DevCtl <C1:05> ResCnd OperationId [1] IsNormal[1] 
[2026-08-08 20:29:32.993 UTC] [V] OFSCtrl Rcv set p_pv:-840.000000
[2026-08-08 20:29:32.993 UTC] [V] 485DevCtl <C1:05> [01][601259][-84.000000][2][kW]
[2026-08-08 20:29:32.993 UTC] [V] SummDat SetVrmValue dev_id:5 val:-840.000000 sc:3
[2026-08-08 20:29:32.994 UTC] [V] OCMgr SetMeterValue PhId:0105, branchNo:01, valueId:601259, value:-84.000000, scaleFactor:2, devId:5
[2026-08-08 20:29:32.994 UTC] [V] 485DevCtl <C1:05> [01][603259][1279289.000000][1][kWh]
[2026-08-08 20:29:32.994 UTC] [V] SummDat SetVrmValue dev_id:5 val:1279289.000000 sc:1
[2026-08-08 20:29:33.002 UTC] [V] OCMgr SetMeterValue PhId:0105, branchNo:01, valueId:603259, value:1279289.000000, scaleFactor:1, devId:5
[2026-08-08 20:29:33.006 UTC] [V] 485DevCtl <C1:05> device_type:PV-Meter
[2026-08-08 20:29:33.012 UTC] [V] 485ChCtl <C1> set rt:0
[2026-08-08 20:29:33.027 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:33.027 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:33.093 UTC] [V] 485ChCtl <C1> StartDeviceCommunicationForOutputFluctuationSuppressionControlBroadcast 4 cnt:3604977, monitor_cnt:116, bc_elapsed:27, min:10, max:40
[2026-08-08 20:29:33.093 UTC] [V] 485DevCtl <C1:06> Dev not PCS IsNeedToChangeOControlState
[2026-08-08 20:29:33.093 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :1
[2026-08-08 20:29:33.094 UTC] [V] 485ChCtl <C1> send request:omron06
[2026-08-08 20:29:33.095 UTC] [D] 485AcReq <C1:06> PutOStream [1][08000603000000144472]
[2026-08-08 20:29:33.128 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:33.128 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:33.228 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:33.228 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:33.328 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:33.328 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:33.328 UTC] [V] OFSCtrl Control charge discharge proc start.
[2026-08-08 20:29:33.328 UTC] [V] OFSCtrl CHG 20 p_th(t):-1109.900000 = p_th_old_:-1100.000000 + lev_cd_:-0.300000 * (total_pcs_capacity_:99000.000000 * cof_spec_:2.000000 / 60 * (time_threshold_renew:10.000000 * 10)), min:-1100.000000, max:119300.000000
[2026-08-08 20:29:33.329 UTC] [V] OFSCtrl CHG 21 batt_w:265.057026 = old:268.494526 +  kp:0.550000 * e:-6.250000 + ki:0.000000 * sume:9163074.450228 + kd:0.040000 * (e:-6.250000 - e1:-6.250000)
[2026-08-08 20:29:33.329 UTC] [V] OFSCtrl CHG 29 q:2.000000, mod(round):1.000000
[2026-08-08 20:29:33.329 UTC] [D] OFSCtrl battery ctrl val:0.500000
[2026-08-08 20:29:33.329 UTC] [V] 485ChCtl <C3> battery limit on [3.000000,] request.
[2026-08-08 20:29:33.329 UTC] [V] OFSCtrl Control charge discharge proc:01->02->BATT_CHK->03->04->05->06->07->10->11->20->21->22->23->24->25->27->28->29->30->31->32->33->34
[2026-08-08 20:29:33.330 UTC] [V] 485ChCtl <C3> battery send request.1
[2026-08-08 20:29:33.330 UTC] [D] VarInf Limit_Bat rt[2]set val[3] set rate[0.600000] value100[500] value-100[-500]
[2026-08-08 20:29:33.333 UTC] [D] 485AcReq <C3:01> PutOStream [6][0f000001000000090110278e0001020003]
[2026-08-08 20:29:33.428 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:33.428 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:33.477 UTC] [V] 485DevCtl <C3:01> AnalyzeResponseData proc restart cnt:360492 UPRstat:0
[2026-08-08 20:29:33.480 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-08 20:29:33.481 UTC] [D] 485DevCtl <C3:01> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-08 20:29:33.481 UTC] [D] 485DevCtl <C3:01> ResCnd OperationId [6] IsNormal[1] 
[2026-08-08 20:29:33.481 UTC] [V] 485DevCtl <C3:01> device_type:Battery
[2026-08-08 20:29:33.481 UTC] [V] 485ChCtl <C3> set rt:0
[2026-08-08 20:29:33.487 UTC] [V] 485DevCtl <C1:06> AnalyzeResponseData proc restart cnt:360485 UPRstat:0
[2026-08-08 20:29:33.487 UTC] [V] Res no response condition. set normal condition.
[2026-08-08 20:29:33.489 UTC] [D] 485DevCtl <C1:06> RcvDat status[2] len[45] [0603280000080700000816000008130000098700000a680000091e000000640000025800000b570000001d59ac]
[2026-08-08 20:29:33.489 UTC] [D] 485DevCtl <C1:06> ResCnd OperationId [1] IsNormal[1] 
[2026-08-08 20:29:33.490 UTC] [V] OFSCtrl Rcv set p_batt:290.000000
[2026-08-08 20:29:33.490 UTC] [V] 485DevCtl <C1:06> [01][601237][29.000000][2][kW]
[2026-08-08 20:29:33.490 UTC] [V] SummDat SetVrmValue dev_id:6 val:290.000000 sc:3
[2026-08-08 20:29:33.491 UTC] [V] OCMgr SetMeterValue PhId:0106, branchNo:01, valueId:601237, value:29.000000, scaleFactor:2, devId:6
[2026-08-08 20:29:33.491 UTC] [V] 485DevCtl <C1:06> device_type:Batt-Meter
[2026-08-08 20:29:33.492 UTC] [V] 485ChCtl <C1> set rt:0
[2026-08-08 20:29:33.497 UTC] [D] 485ChCtl <C1> monitoring dev All Send
[2026-08-08 20:29:33.528 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:33.528 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:33.628 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:33.628 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:33.678 UTC] [V] OFSCtrl [/var/local/solajithome/function/output_fluctuation_suppression/batt_data] write success.
[2026-08-08 20:29:33.728 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:33.728 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:33.828 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:33.828 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:33.928 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:33.928 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:34.028 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:34.028 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:34.128 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:34.128 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:34.227 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:34.228 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:34.327 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:34.328 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:34.328 UTC] [V] OFSCtrl Control charge discharge proc start.
[2026-08-08 20:29:34.328 UTC] [V] OFSCtrl CHG 20 p_th(t):-1109.900000 = p_th_old_:-1100.000000 + lev_cd_:-0.300000 * (total_pcs_capacity_:99000.000000 * cof_spec_:2.000000 / 60 * (time_threshold_renew:10.000000 * 10)), min:-1100.000000, max:119300.000000
[2026-08-08 20:29:34.328 UTC] [V] OFSCtrl CHG 21 batt_w:261.619526 = old:265.057026 +  kp:0.550000 * e:-6.250000 + ki:0.000000 * sume:9163068.200228 + kd:0.040000 * (e:-6.250000 - e1:-6.250000)
[2026-08-08 20:29:34.329 UTC] [V] OFSCtrl CHG 29 q:2.000000, mod(round):1.000000
[2026-08-08 20:29:34.329 UTC] [D] OFSCtrl battery ctrl val:0.500000
[2026-08-08 20:29:34.329 UTC] [V] 485ChCtl <C3> battery limit on [3.000000,] request.
[2026-08-08 20:29:34.329 UTC] [V] OFSCtrl Control charge discharge proc:01->02->BATT_CHK->03->04->05->06->07->10->11->20->21->22->23->24->25->27->28->29->30->31->32->33->34
[2026-08-08 20:29:34.330 UTC] [V] 485ChCtl <C3> battery send request.1
[2026-08-08 20:29:34.330 UTC] [D] VarInf Limit_Bat rt[2]set val[3] set rate[0.600000] value100[500] value-100[-500]
[2026-08-08 20:29:34.332 UTC] [D] 485AcReq <C3:01> PutOStream [6][0f000001000000090110278e0001020003]
[2026-08-08 20:29:34.428 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:34.428 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:34.477 UTC] [V] 485DevCtl <C3:01> AnalyzeResponseData proc restart cnt:360493 UPRstat:0
[2026-08-08 20:29:34.480 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-08 20:29:34.480 UTC] [D] 485DevCtl <C3:01> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-08 20:29:34.481 UTC] [D] 485DevCtl <C3:01> ResCnd OperationId [6] IsNormal[1] 
[2026-08-08 20:29:34.481 UTC] [V] 485DevCtl <C3:01> device_type:Battery
[2026-08-08 20:29:34.481 UTC] [V] 485ChCtl <C3> set rt:0
[2026-08-08 20:29:34.528 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:34.528 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:34.628 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:34.628 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:34.678 UTC] [V] OFSCtrl [/var/local/solajithome/function/output_fluctuation_suppression/batt_data] write success.
[2026-08-08 20:29:34.727 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:34.728 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:34.827 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:34.828 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:34.910 UTC] [V] 485ChCtl <C2> StartDeviceCommunicationForOutputFluctuationSuppressionControlBroadcast 4 cnt:3604995, monitor_cnt:50, bc_elapsed:3604995, min:10, max:40
[2026-08-08 20:29:34.910 UTC] [V] OFSCtrl /var/local/solajithome/function/output_fluctuation_suppression/state is exist:0
[2026-08-08 20:29:34.910 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :1
[2026-08-08 20:29:34.911 UTC] [V] 485ChCtl <C2> send request:Sungrow08
[2026-08-08 20:29:34.911 UTC] [D] 485AcReq <C2:01> PutOStream [1][08000104138a0024d57f]
[2026-08-08 20:29:34.928 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:34.928 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:35.028 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:35.028 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:35.038 UTC] [V] CIStDb UpdateStatusData. [SELECT no, on_time, off_time FROM contact_input_status WHERE no BETWEEN '1' AND '9' ORDER BY no ASC ]
[2026-08-08 20:29:35.128 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:35.128 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:35.228 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:35.228 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:35.314 UTC] [V] Res no response condition. set normal condition.
[2026-08-08 20:29:35.317 UTC] [D] 485DevCtl <C2:01> RcvDat status[2] len[77] [0104480000fcc00000172b000000000000000000000000000000000000000000000000000000000000000000000000ffffffffffffffffffffffff000000000000000000000000000014002f98]
[2026-08-08 20:29:35.317 UTC] [D] 485DevCtl <C2:01> ResCnd OperationId [1] IsNormal[1] 
[2026-08-08 20:29:35.322 UTC] [V] 485DevCtl <C2:01> [01][115202][0.000000][1][kWh]
[2026-08-08 20:29:35.324 UTC] [V] SummDat SetVrmValue dev_id:7 val:0.000000 sc:1
[2026-08-08 20:29:35.327 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:35.328 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:35.328 UTC] [V] OFSCtrl Control charge discharge proc start.
[2026-08-08 20:29:35.328 UTC] [V] OFSCtrl CHG 20 p_th(t):-1109.900000 = p_th_old_:-1100.000000 + lev_cd_:-0.300000 * (total_pcs_capacity_:99000.000000 * cof_spec_:2.000000 / 60 * (time_threshold_renew:10.000000 * 10)), min:-1100.000000, max:119300.000000
[2026-08-08 20:29:35.328 UTC] [V] OFSCtrl CHG 21 batt_w:258.182026 = old:261.619526 +  kp:0.550000 * e:-6.250000 + ki:0.000000 * sume:9163061.950228 + kd:0.040000 * (e:-6.250000 - e1:-6.250000)
[2026-08-08 20:29:35.329 UTC] [V] OFSCtrl CHG 29 q:2.000000, mod(round):1.000000
[2026-08-08 20:29:35.329 UTC] [D] OFSCtrl battery ctrl val:0.500000
[2026-08-08 20:29:35.329 UTC] [V] 485ChCtl <C3> battery limit on [3.000000,] request.
[2026-08-08 20:29:35.329 UTC] [V] OFSCtrl Control charge discharge proc:01->02->BATT_CHK->03->04->05->06->07->10->11->20->21->22->23->24->25->27->28->29->30->31->32->33->34
[2026-08-08 20:29:35.330 UTC] [V] 485ChCtl <C3> battery send request.1
[2026-08-08 20:29:35.330 UTC] [D] VarInf Limit_Bat rt[2]set val[3] set rate[0.600000] value100[500] value-100[-500]
[2026-08-08 20:29:35.332 UTC] [D] 485AcReq <C3:01> PutOStream [6][0f000001000000090110278e0001020003]
[2026-08-08 20:29:35.338 UTC] [V] OCMgr SetMeterValue PhId:0201, branchNo:01, valueId:115202, value:0.000000, scaleFactor:1, devId:7
[2026-08-08 20:29:35.338 UTC] [V] 485DevCtl <C2:01> [01][113202][64704.000000][0][kWh]
[2026-08-08 20:29:35.338 UTC] [V] SummDat SetVrmValue dev_id:7 val:64704.000000 sc:0
[2026-08-08 20:29:35.338 UTC] [V] OCMgr SetMeterValue PhId:0201, branchNo:01, valueId:113202, value:64704.000000, scaleFactor:0, devId:7
[2026-08-08 20:29:35.339 UTC] [V] 485DevCtl <C2:01> [01][121005][0.000000][1][℃]
[2026-08-08 20:29:35.339 UTC] [V] SummDat SetVrmValue dev_id:7 val:0.000000 sc:3
[2026-08-08 20:29:35.339 UTC] [V] OCMgr SetMeterValue PhId:0201, branchNo:01, valueId:121005, value:0.000000, scaleFactor:1, devId:7
[2026-08-08 20:29:35.339 UTC] [V] 485DevCtl <C2:01> [01][101100][0.000000][1][V]
[2026-08-08 20:29:35.339 UTC] [V] SummDat SetVrmValue dev_id:7 val:0.000000 sc:3
[2026-08-08 20:29:35.354 UTC] [V] OCMgr SetMeterValue PhId:0201, branchNo:01, valueId:101100, value:0.000000, scaleFactor:1, devId:7
[2026-08-08 20:29:35.362 UTC] [V] 485DevCtl <C2:01> [01][101101][0.000000][1][A]
[2026-08-08 20:29:35.365 UTC] [V] SummDat SetVrmValue dev_id:7 val:0.000000 sc:3
[2026-08-08 20:29:35.366 UTC] [V] OCMgr SetMeterValue PhId:0201, branchNo:01, valueId:101101, value:0.000000, scaleFactor:1, devId:7
[2026-08-08 20:29:35.367 UTC] [V] 485DevCtl <C2:01> [02][101100][0.000000][1][V]
[2026-08-08 20:29:35.374 UTC] [V] SummDat SetVrmValue dev_id:7 val:0.000000 sc:3
[2026-08-08 20:29:35.378 UTC] [V] OCMgr SetMeterValue PhId:0201, branchNo:02, valueId:101100, value:0.000000, scaleFactor:1, devId:7
[2026-08-08 20:29:35.384 UTC] [V] 485DevCtl <C2:01> [02][101101][0.000000][1][A]
[2026-08-08 20:29:35.387 UTC] [V] SummDat SetVrmValue dev_id:7 val:0.000000 sc:3
[2026-08-08 20:29:35.393 UTC] [V] 485DevCtl <C1:01> device_type:Irr-Meter
[2026-08-08 20:29:35.393 UTC] [V] 485DevCtl <C1:01> device_type:Irr-Meter
[2026-08-08 20:29:35.393 UTC] [V] 485ChCtl <C1> fixed cycle Irr-Meter
[2026-08-08 20:29:35.393 UTC] [V] 485DevCtl <C1:01> Dev not PCS IsNeedToChangeOControlState
[2026-08-08 20:29:35.394 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :1
[2026-08-08 20:29:35.394 UTC] [V] 485ChCtl <C1> send request:Irr01
[2026-08-08 20:29:35.395 UTC] [D] 485AcReq <C1:01> PutOStream [1][080001040000000271cb]
[2026-08-08 20:29:35.398 UTC] [V] OCMgr SetMeterValue PhId:0201, branchNo:02, valueId:101101, value:0.000000, scaleFactor:1, devId:7
[2026-08-08 20:29:35.398 UTC] [V] 485DevCtl <C2:01> [03][101100][0.000000][1][V]
[2026-08-08 20:29:35.398 UTC] [V] SummDat SetVrmValue dev_id:7 val:0.000000 sc:3
[2026-08-08 20:29:35.399 UTC] [V] OCMgr SetMeterValue PhId:0201, branchNo:03, valueId:101100, value:0.000000, scaleFactor:1, devId:7
[2026-08-08 20:29:35.399 UTC] [V] 485DevCtl <C2:01> [03][101101][0.000000][1][A]
[2026-08-08 20:29:35.399 UTC] [V] SummDat SetVrmValue dev_id:7 val:0.000000 sc:3
[2026-08-08 20:29:35.399 UTC] [V] OCMgr SetMeterValue PhId:0201, branchNo:03, valueId:101101, value:0.000000, scaleFactor:1, devId:7
[2026-08-08 20:29:35.400 UTC] [V] 485DevCtl <C2:01> [01][101102][0.000000][0][W]
[2026-08-08 20:29:35.400 UTC] [V] SummDat SetVrmValue dev_id:7 val:0.000000 sc:3
[2026-08-08 20:29:35.400 UTC] [V] OCMgr SetMeterValue PhId:0201, branchNo:01, valueId:101102, value:0.000000, scaleFactor:0, devId:7
[2026-08-08 20:29:35.421 UTC] [V] 485DevCtl <C2:01> [01][111200][0.000000][1][V]
[2026-08-08 20:29:35.421 UTC] [V] SummDat SetVrmValue dev_id:7 val:0.000000 sc:3
[2026-08-08 20:29:35.421 UTC] [V] OCMgr SetMeterValue PhId:0201, branchNo:01, valueId:111200, value:0.000000, scaleFactor:1, devId:7
[2026-08-08 20:29:35.422 UTC] [V] 485DevCtl <C2:01> [02][111200][0.000000][1][V]
[2026-08-08 20:29:35.422 UTC] [V] SummDat SetVrmValue dev_id:7 val:0.000000 sc:3
[2026-08-08 20:29:35.422 UTC] [V] OCMgr SetMeterValue PhId:0201, branchNo:02, valueId:111200, value:0.000000, scaleFactor:1, devId:7
[2026-08-08 20:29:35.428 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:35.428 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:35.428 UTC] [V] 485DevCtl <C2:01> [03][111200][0.000000][1][V]
[2026-08-08 20:29:35.429 UTC] [V] SummDat SetVrmValue dev_id:7 val:0.000000 sc:3
[2026-08-08 20:29:35.432 UTC] [V] OCMgr SetMeterValue PhId:0201, branchNo:03, valueId:111200, value:0.000000, scaleFactor:1, devId:7
[2026-08-08 20:29:35.440 UTC] [V] 485DevCtl <C2:01> [01][111201][0.000000][1][A]
[2026-08-08 20:29:35.443 UTC] [V] SummDat SetVrmValue dev_id:7 val:0.000000 sc:3
[2026-08-08 20:29:35.456 UTC] [V] OCMgr SetMeterValue PhId:0201, branchNo:01, valueId:111201, value:0.000000, scaleFactor:1, devId:7
[2026-08-08 20:29:35.456 UTC] [V] 485DevCtl <C2:01> [02][111201][0.000000][1][A]
[2026-08-08 20:29:35.456 UTC] [V] SummDat SetVrmValue dev_id:7 val:0.000000 sc:3
[2026-08-08 20:29:35.457 UTC] [V] OCMgr SetMeterValue PhId:0201, branchNo:02, valueId:111201, value:0.000000, scaleFactor:1, devId:7
[2026-08-08 20:29:35.457 UTC] [V] 485DevCtl <C2:01> [03][111201][0.000000][1][A]
[2026-08-08 20:29:35.457 UTC] [V] SummDat SetVrmValue dev_id:7 val:0.000000 sc:3
[2026-08-08 20:29:35.463 UTC] [V] OCMgr SetMeterValue PhId:0201, branchNo:03, valueId:111201, value:0.000000, scaleFactor:1, devId:7
[2026-08-08 20:29:35.465 UTC] [V] 485DevCtl <C2:01> [01][111202][0.000000][0][W]
[2026-08-08 20:29:35.469 UTC] [V] SummDat SetVrmValue dev_id:7 val:0.000000 sc:3
[2026-08-08 20:29:35.481 UTC] [V] OCMgr SetMeterValue PhId:0201, branchNo:01, valueId:111202, value:0.000000, scaleFactor:0, devId:7
[2026-08-08 20:29:35.482 UTC] [V] 485DevCtl <C2:01> [01][111203][0.000000][0][var]
[2026-08-08 20:29:35.482 UTC] [V] SummDat SetVrmValue dev_id:7 val:0.000000 sc:3
[2026-08-08 20:29:35.482 UTC] [V] OCMgr SetMeterValue PhId:0201, branchNo:01, valueId:111203, value:0.000000, scaleFactor:0, devId:7
[2026-08-08 20:29:35.482 UTC] [V] 485DevCtl <C2:01> [01][121007][0.000000][3][]
[2026-08-08 20:29:35.483 UTC] [V] SummDat SetVrmValue dev_id:7 val:0.000000 sc:3
[2026-08-08 20:29:35.483 UTC] [V] OCMgr SetMeterValue PhId:0201, branchNo:01, valueId:121007, value:0.000000, scaleFactor:3, devId:7
[2026-08-08 20:29:35.483 UTC] [V] 485DevCtl <C2:01> [01][131006][0.000000][1][Hz]
[2026-08-08 20:29:35.483 UTC] [V] SummDat SetVrmValue dev_id:7 val:0.000000 sc:3
[2026-08-08 20:29:35.487 UTC] [V] 485DevCtl <C3:01> AnalyzeResponseData proc restart cnt:360494 UPRstat:0
[2026-08-08 20:29:35.489 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-08 20:29:35.490 UTC] [D] 485DevCtl <C3:01> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-08 20:29:35.490 UTC] [D] 485DevCtl <C3:01> ResCnd OperationId [6] IsNormal[1] 
[2026-08-08 20:29:35.490 UTC] [V] 485DevCtl <C3:01> device_type:Battery
[2026-08-08 20:29:35.490 UTC] [V] 485ChCtl <C3> set rt:0
[2026-08-08 20:29:35.493 UTC] [V] OCMgr SetMeterValue PhId:0201, branchNo:01, valueId:131006, value:0.000000, scaleFactor:1, devId:7
[2026-08-08 20:29:35.499 UTC] [V] 485DevCtl <C2:01> [01][114202][64704.000000][0][kWh]
[2026-08-08 20:29:35.502 UTC] [V] SummDat SetVrmValue dev_id:7 val:64704000.000000 sc:3
[2026-08-08 20:29:35.510 UTC] [V] OCMgr SetMeterValue PhId:0201, branchNo:01, valueId:114202, value:64704.000000, scaleFactor:0, devId:7
[2026-08-08 20:29:35.517 UTC] [V] 485DevCtl <C2:01> device_type:PV-PCS
[2026-08-08 20:29:35.520 UTC] [V] 485DevCtl <C2:01> set2 StatusCode[010100] DeviceName[] DeviceNumber[]
[2026-08-08 20:29:35.520 UTC] [V] 485ChCtl <C2> set rt:0
[2026-08-08 20:29:35.527 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:35.528 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:35.610 UTC] [V] 485ChCtl <C2> StartDeviceCommunicationForOutputFluctuationSuppressionControlBroadcast 4 cnt:3605002, monitor_cnt:57, bc_elapsed:3605002, min:10, max:40
[2026-08-08 20:29:35.610 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :9
[2026-08-08 20:29:35.611 UTC] [V] 485ChCtl <C2> send request:Sungrow08
[2026-08-08 20:29:35.612 UTC] [D] 485AcReq <C2:02> PutOStream [9][0800020413fa00179482]
[2026-08-08 20:29:35.628 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:35.628 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:35.678 UTC] [V] OFSCtrl [/var/local/solajithome/function/output_fluctuation_suppression/batt_data] write success.
[2026-08-08 20:29:35.728 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:35.728 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:35.731 UTC] [V] 485ChCtl <C3> StartDeviceCommunicationForOutputFluctuationSuppressionControlBroadcast 4 cnt:3605003, monitor_cnt:50, bc_elapsed:3605003, min:10, max:40
[2026-08-08 20:29:35.731 UTC] [V] OFSCtrl /var/local/solajithome/function/output_fluctuation_suppression/state is exist:0
[2026-08-08 20:29:35.731 UTC] [V] 485DevCtl <C3:01> Dev not PCS IsNeedToChangeOControlState
[2026-08-08 20:29:35.731 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :4
[2026-08-08 20:29:35.732 UTC] [V] 485ChCtl <C3> send request:Sungrow11
[2026-08-08 20:29:35.733 UTC] [V] 485DevCtl <C1:01> AnalyzeResponseData proc restart cnt:360496 UPRstat:0
[2026-08-08 20:29:35.733 UTC] [V] Res no response condition. set normal condition.
[2026-08-08 20:29:35.733 UTC] [D] 485DevCtl <C1:01> RcvDat status[2] len[9] [010404000002013b24]
[2026-08-08 20:29:35.733 UTC] [D] 485DevCtl <C1:01> ResCnd OperationId [1] IsNormal[1] 
[2026-08-08 20:29:35.734 UTC] [V] OFSCtrl Rcv set flux_of_solar:0.000000
[2026-08-08 20:29:35.734 UTC] [V] 485DevCtl <C1:01> [01][401006][0.000000][1][W/m2]
[2026-08-08 20:29:35.734 UTC] [V] SummDat SetVrmValue dev_id:1 val:0.000000 sc:3
[2026-08-08 20:29:35.734 UTC] [V] OCMgr SetMeterValue PhId:0101, branchNo:01, valueId:401006, value:0.000000, scaleFactor:1, devId:1
[2026-08-08 20:29:35.735 UTC] [V] 485DevCtl <C1:01> [01][421005][263.000000][1][℃]
[2026-08-08 20:29:35.735 UTC] [V] SummDat SetVrmValue dev_id:1 val:26300.000000 sc:3
[2026-08-08 20:29:35.737 UTC] [D] 485AcReq <C3:01> PutOStream [4][0c00000100000006010427f0002f]
[2026-08-08 20:29:35.742 UTC] [V] OCMgr SetMeterValue PhId:0101, branchNo:01, valueId:421005, value:263.000000, scaleFactor:1, devId:1
[2026-08-08 20:29:35.745 UTC] [V] 485DevCtl <C1:01> device_type:Irr-Meter
[2026-08-08 20:29:35.746 UTC] [V] OFSCtrl Irr-Meter received.
[2026-08-08 20:29:35.760 UTC] [V] 485ChCtl <C1> set rt:0
[2026-08-08 20:29:35.763 UTC] [V] 485DevCtl <C1:01> device_type:Irr-Meter
[2026-08-08 20:29:35.793 UTC] [V] 485DevCtl <C1:04> device_type:CO-Meter
[2026-08-08 20:29:35.793 UTC] [V] 485DevCtl <C1:04> device_type:CO-Meter
[2026-08-08 20:29:35.793 UTC] [V] 485ChCtl <C1> fixed cycle CO-Meter
[2026-08-08 20:29:35.793 UTC] [V] 485DevCtl <C1:04> Dev not PCS IsNeedToChangeOControlState
[2026-08-08 20:29:35.793 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :1
[2026-08-08 20:29:35.794 UTC] [V] 485ChCtl <C1> send request:omron05
[2026-08-08 20:29:35.796 UTC] [D] 485AcReq <C1:04> PutOStream [1][0800040300030014b590]
[2026-08-08 20:29:35.828 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:35.828 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:35.897 UTC] [V] 485DevCtl <C3:01> AnalyzeResponseData proc restart cnt:360495 UPRstat:0
[2026-08-08 20:29:35.906 UTC] [D] 485DevCtl <C3:01> RcvDat status[0] len[103] [00010000006101045e1e16000800040fc10fc20fde000b000c000b000400000000000000000000000000000001000000939df7000091710000012c000000670141302a00000001177003e701d00000014100d9000019eb00002f4b000100040000000000930000]
[2026-08-08 20:29:35.910 UTC] [D] 485DevCtl <C3:01> ResCnd OperationId [4] IsNormal[1]  ConditionType [lggrdev:Normal] Action[-1]
[2026-08-08 20:29:35.916 UTC] [V] 485DevCtl <C3:01> [05][753053][0.000000][0][]
[2026-08-08 20:29:35.916 UTC] [V] SummDat SetVrmValue dev_id:9 val:0.000000 sc:0
[2026-08-08 20:29:35.926 UTC] [V] OCMgr SetMeterValue PhId:0301, branchNo:05, valueId:753053, value:0.000000, scaleFactor:0, devId:9
[2026-08-08 20:29:35.927 UTC] [V] 485DevCtl <C3:01> [06][753053][0.000000][0][]
[2026-08-08 20:29:35.928 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:35.928 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:35.936 UTC] [V] SummDat SetVrmValue dev_id:9 val:0.000000 sc:0
[2026-08-08 20:29:35.940 UTC] [V] OCMgr SetMeterValue PhId:0301, branchNo:06, valueId:753053, value:0.000000, scaleFactor:0, devId:9
[2026-08-08 20:29:35.940 UTC] [V] 485DevCtl <C3:01> [07][753053][0.000000][0][]
[2026-08-08 20:29:35.949 UTC] [V] SummDat SetVrmValue dev_id:9 val:0.000000 sc:0
[2026-08-08 20:29:35.953 UTC] [V] OCMgr SetMeterValue PhId:0301, branchNo:07, valueId:753053, value:0.000000, scaleFactor:0, devId:9
[2026-08-08 20:29:35.961 UTC] [V] 485DevCtl <C3:01> device_type:Battery
[2026-08-08 20:29:35.966 UTC] [V] 485DevCtl <C3:01> set2 StatusCode[020101]
[2026-08-08 20:29:35.971 UTC] [V] OFSCtrl Bat[0301] StCd[020101]->st[1].
[2026-08-08 20:29:35.972 UTC] [V] OFSCtrl set batt status:[0301]:Drive, All:[0301]:Drive, [DRIVE] 
[2026-08-08 20:29:35.972 UTC] [V] OFSCtrl change set SOC(t):11.000000 drive cnt:1
[2026-08-08 20:29:35.986 UTC] [V] Res no response condition. set normal condition.
[2026-08-08 20:29:35.987 UTC] [D] 485DevCtl <C2:02> RcvDat status[2] len[51] [02042e000000000000000000000000ffffffffffffffff03e8ffffffff420e0000ffffffffffffffffffffffffffffffff914e]
[2026-08-08 20:29:35.987 UTC] [D] 485DevCtl <C2:02> ResCnd OperationId [9] IsNormal[1] 
[2026-08-08 20:29:35.989 UTC] [V] 485DevCtl <C2:02> [04][101100][0.000000][1][V]
[2026-08-08 20:29:35.989 UTC] [V] SummDat SetVrmValue dev_id:8 val:0.000000 sc:3
[2026-08-08 20:29:35.989 UTC] [V] OCMgr SetMeterValue PhId:0202, branchNo:04, valueId:101100, value:0.000000, scaleFactor:1, devId:8
[2026-08-08 20:29:35.990 UTC] [V] 485DevCtl <C2:02> [04][101101][0.000000][1][A]
[2026-08-08 20:29:35.990 UTC] [V] SummDat SetVrmValue dev_id:8 val:0.000000 sc:3
[2026-08-08 20:29:35.990 UTC] [V] OCMgr SetMeterValue PhId:0202, branchNo:04, valueId:101101, value:0.000000, scaleFactor:1, devId:8
[2026-08-08 20:29:35.990 UTC] [V] 485DevCtl <C2:02> [05][101100][0.000000][1][V]
[2026-08-08 20:29:35.993 UTC] [V] 485DevCtl <C3:01> set2 StatusCode[020101] DeviceName[蓄電池1] DeviceNumber[1]
[2026-08-08 20:29:35.993 UTC] [V] 485ChCtl <C3> set rt:0
[2026-08-08 20:29:35.994 UTC] [D] 485ChCtl <C3> monitoring dev All Send
[2026-08-08 20:29:36.000 UTC] [V] SummDat SetVrmValue dev_id:8 val:0.000000 sc:3
[2026-08-08 20:29:36.008 UTC] [V] OCMgr SetMeterValue PhId:0202, branchNo:05, valueId:101100, value:0.000000, scaleFactor:1, devId:8
[2026-08-08 20:29:36.008 UTC] [V] 485DevCtl <C2:02> [05][101101][0.000000][1][A]
[2026-08-08 20:29:36.008 UTC] [V] SummDat SetVrmValue dev_id:8 val:0.000000 sc:3
[2026-08-08 20:29:36.008 UTC] [V] OCMgr SetMeterValue PhId:0202, branchNo:05, valueId:101101, value:0.000000, scaleFactor:1, devId:8
[2026-08-08 20:29:36.009 UTC] [V] 485DevCtl <C2:02> [06][101100][0.000000][1][V]
[2026-08-08 20:29:36.009 UTC] [V] SummDat SetVrmValue dev_id:8 val:0.000000 sc:3
[2026-08-08 20:29:36.009 UTC] [V] OCMgr SetMeterValue PhId:0202, branchNo:06, valueId:101100, value:0.000000, scaleFactor:1, devId:8
[2026-08-08 20:29:36.009 UTC] [V] 485DevCtl <C2:02> [06][101101][0.000000][1][A]
[2026-08-08 20:29:36.024 UTC] [V] SummDat SetVrmValue dev_id:8 val:0.000000 sc:3
[2026-08-08 20:29:36.027 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:36.027 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:36.030 UTC] [V] OCMgr SetMeterValue PhId:0202, branchNo:06, valueId:101101, value:0.000000, scaleFactor:1, devId:8
[2026-08-08 20:29:36.046 UTC] [V] 485DevCtl <C2:02> device_type:PV-PCS
[2026-08-08 20:29:36.048 UTC] [V] 485ChCtl <C2> set rt:0
[2026-08-08 20:29:36.049 UTC] [D] 485ChCtl <C2> monitoring dev All Send
[2026-08-08 20:29:36.127 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:36.127 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:36.199 UTC] [V] 485DevCtl <C1:04> AnalyzeResponseData proc restart cnt:360495 UPRstat:0
[2026-08-08 20:29:36.199 UTC] [V] Res no response condition. set normal condition.
[2026-08-08 20:29:36.200 UTC] [D] 485DevCtl <C1:04> RcvDat status[2] len[45] [040328000022320000180a000017f8ffffffe500000258ffffe8daffffffc5ffffaf2bffffff3200121a818650]
[2026-08-08 20:29:36.200 UTC] [D] 485DevCtl <C1:04> ResCnd OperationId [1] IsNormal[1] 
[2026-08-08 20:29:36.201 UTC] [V] OFSCtrl Rcv set p_co:-590.000000, p_co_old:-590.000000
[2026-08-08 20:29:36.201 UTC] [V] 485DevCtl <C1:04> [01][601260][-59.000000][2][kW]
[2026-08-08 20:29:36.201 UTC] [V] SummDat SetVrmValue dev_id:4 val:-590.000000 sc:3
[2026-08-08 20:29:36.201 UTC] [V] OCMgr SetMeterValue PhId:0104, branchNo:01, valueId:601260, value:-59.000000, scaleFactor:2, devId:4
[2026-08-08 20:29:36.202 UTC] [V] 485DevCtl <C1:04> [01][603260][1186433.000000][1][kWh]
[2026-08-08 20:29:36.202 UTC] [V] SummDat SetVrmValue dev_id:4 val:1186433.000000 sc:1
[2026-08-08 20:29:36.202 UTC] [V] OCMgr SetMeterValue PhId:0104, branchNo:01, valueId:603260, value:1186433.000000, scaleFactor:1, devId:4
[2026-08-08 20:29:36.202 UTC] [V] 485DevCtl <C1:04> device_type:CO-Meter
[2026-08-08 20:29:36.203 UTC] [V] OFSCtrl km50 received.
[2026-08-08 20:29:36.203 UTC] [V] OFSCtrl omron05_local_date :2026/08/09 ? 2026/08/09
[2026-08-08 20:29:36.203 UTC] [V] OFSCtrl omron05_local_time :2026/08/09 05 ? 2026/08/09 05
[2026-08-08 20:29:36.203 UTC] [V] OFSCtrl out of control time.
[2026-08-08 20:29:36.203 UTC] [V] OFSCtrl Control pv-pcs proc start.
[2026-08-08 20:29:36.203 UTC] [V] OFSCtrl NOD_month:-1664.000000 = (NOD_month:306 - ((nod_max_/30):23.333333 * (cnt-1):25) * (30/cnt):6.000000 
[2026-08-08 20:29:36.204 UTC] [V] OFSCtrl PCS ratio_month:232.646617 = -k_inhibition_ratio_month:-0.097744 * NOD_month:-1664.000000 + inhibition_ratio_max:70
[2026-08-08 20:29:36.204 UTC] [V] OFSCtrl PCS 05 inhibition_ratio:70.000000 = max(ratio_min:5, min(ratio:70, ratio_hour:70.000000, ratio_day:70.000000, ratio_month:232.646617))
[2026-08-08 20:29:36.204 UTC] [D] OFSCtrl pv-pcs ctrl val:0.000000 old:0.000000
[2026-08-08 20:29:36.204 UTC] [V] OCHisDB set rate:0 t_rate:0 cnt:54
[2026-08-08 20:29:36.204 UTC] [V] 485ChCtl <C2> pv-pcs limit on [0.000000] request.
[2026-08-08 20:29:36.204 UTC] [V] OFSCtrl Control pv-pcs proc:BATT_CHK->01->02->03->04->05->06->07->09->09->10->11->12
[2026-08-08 20:29:36.209 UTC] [V] 485ChCtl <C2> pv-pcs send request.
[2026-08-08 20:29:36.210 UTC] [D] VarInf update ofs_rate:0.000000
[2026-08-08 20:29:36.210 UTC] [V] VarInf LimitSet rt[2] val[170] key[ValueOn]
[2026-08-08 20:29:36.210 UTC] [D] VarInf output_mode:8
[2026-08-08 20:29:36.210 UTC] [D] VarInf update ofs_rate:0.000000
[2026-08-08 20:29:36.210 UTC] [D] VarInf Limit setRate[0.000000] rate[0.000000] value100[1000.000000] value0[0.000000]
[2026-08-08 20:29:36.210 UTC] [V] 485DevCtl <C2:01> ChangeOutputRateToDevice rate:0.000000 set_rate1
[2026-08-08 20:29:36.210 UTC] [D] VarInf Limit rt[2] int_set_rate[1] server_rate[0.000000] rated_output[100.000000] solar_battery_power[100.000000]
[2026-08-08 20:29:36.211 UTC] [D] 485AcReq <C2:01> PutOStreamForBc [3][0d000010138e00020400aa0001466f]
[2026-08-08 20:29:36.227 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:36.227 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:36.238 UTC] [V] 485ChCtl <C1> set rt:0
[2026-08-08 20:29:36.240 UTC] [V] 485DevCtl <C1:04> device_type:CO-Meter
[2026-08-08 20:29:36.328 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:36.328 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:36.328 UTC] [V] OFSCtrl Control charge discharge proc start.
[2026-08-08 20:29:36.329 UTC] [V] OFSCtrl CHG 20 p_th(t):-1109.900000 = p_th_old_:-1100.000000 + lev_cd_:-0.300000 * (total_pcs_capacity_:99000.000000 * cof_spec_:2.000000 / 60 * (time_threshold_renew:10.000000 * 10)), min:-1100.000000, max:119300.000000
[2026-08-08 20:29:36.329 UTC] [V] OFSCtrl CHG 21 batt_w:254.744526 = old:258.182026 +  kp:0.550000 * e:-6.250000 + ki:0.000000 * sume:9163055.700228 + kd:0.040000 * (e:-6.250000 - e1:-6.250000)
[2026-08-08 20:29:36.329 UTC] [V] OFSCtrl CHG 29 q:2.000000, mod(round):1.000000
[2026-08-08 20:29:36.330 UTC] [D] OFSCtrl battery ctrl val:0.500000
[2026-08-08 20:29:36.331 UTC] [V] 485ChCtl <C3> battery limit on [3.000000,] request.
[2026-08-08 20:29:36.331 UTC] [V] OFSCtrl Control charge discharge proc:01->02->BATT_CHK->03->04->05->06->07->10->11->20->21->22->23->24->25->27->28->29->30->31->32->33->34
[2026-08-08 20:29:36.427 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:36.428 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:36.430 UTC] [V] 485ChCtl <C3> battery send request.1
[2026-08-08 20:29:36.431 UTC] [D] VarInf Limit_Bat rt[2]set val[3] set rate[0.600000] value100[500] value-100[-500]
[2026-08-08 20:29:36.433 UTC] [D] 485AcReq <C3:01> PutOStream [6][0f000001000000090110278e0001020003]
[2026-08-08 20:29:36.503 UTC] [V] 485ChCtl <C2> set rt:0
[2026-08-08 20:29:36.527 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:36.528 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:36.587 UTC] [V] 485DevCtl <C3:01> AnalyzeResponseData proc restart cnt:360496 UPRstat:0
[2026-08-08 20:29:36.590 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-08 20:29:36.592 UTC] [D] 485DevCtl <C3:01> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-08 20:29:36.592 UTC] [D] 485DevCtl <C3:01> ResCnd OperationId [6] IsNormal[1] 
[2026-08-08 20:29:36.592 UTC] [V] 485DevCtl <C3:01> device_type:Battery
[2026-08-08 20:29:36.599 UTC] [V] 485ChCtl <C3> set rt:0
[2026-08-08 20:29:36.627 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:36.628 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:36.678 UTC] [V] OFSCtrl [/var/local/solajithome/function/output_fluctuation_suppression/batt_data] write success.
[2026-08-08 20:29:36.727 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:36.728 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:36.827 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:36.827 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:36.927 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:36.927 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:37.028 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:37.028 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:37.128 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:37.128 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:37.228 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:37.228 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:37.328 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:37.328 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:37.328 UTC] [V] OFSCtrl Control charge discharge proc start.
[2026-08-08 20:29:37.328 UTC] [V] OFSCtrl CHG 20 p_th(t):-1109.900000 = p_th_old_:-1100.000000 + lev_cd_:-0.300000 * (total_pcs_capacity_:99000.000000 * cof_spec_:2.000000 / 60 * (time_threshold_renew:10.000000 * 10)), min:-1100.000000, max:119300.000000
[2026-08-08 20:29:37.329 UTC] [V] OFSCtrl CHG 21 batt_w:251.307026 = old:254.744526 +  kp:0.550000 * e:-6.250000 + ki:0.000000 * sume:9163049.450228 + kd:0.040000 * (e:-6.250000 - e1:-6.250000)
[2026-08-08 20:29:37.329 UTC] [V] OFSCtrl CHG 29 q:2.000000, mod(round):1.000000
[2026-08-08 20:29:37.329 UTC] [D] OFSCtrl battery ctrl val:0.500000
[2026-08-08 20:29:37.329 UTC] [V] 485ChCtl <C3> battery limit on [3.000000,] request.
[2026-08-08 20:29:37.329 UTC] [V] OFSCtrl Control charge discharge proc:01->02->BATT_CHK->03->04->05->06->07->10->11->20->21->22->23->24->25->27->28->29->30->31->32->33->34
[2026-08-08 20:29:37.330 UTC] [V] 485ChCtl <C3> battery send request.1
[2026-08-08 20:29:37.330 UTC] [D] VarInf Limit_Bat rt[2]set val[3] set rate[0.600000] value100[500] value-100[-500]
[2026-08-08 20:29:37.333 UTC] [D] 485AcReq <C3:01> PutOStream [6][0f000001000000090110278e0001020003]
[2026-08-08 20:29:37.428 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:37.428 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:37.477 UTC] [V] 485DevCtl <C3:01> AnalyzeResponseData proc restart cnt:360496 UPRstat:0
[2026-08-08 20:29:37.479 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-08 20:29:37.479 UTC] [D] 485DevCtl <C3:01> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-08 20:29:37.480 UTC] [D] 485DevCtl <C3:01> ResCnd OperationId [6] IsNormal[1] 
[2026-08-08 20:29:37.480 UTC] [V] 485DevCtl <C3:01> device_type:Battery
[2026-08-08 20:29:37.481 UTC] [V] 485ChCtl <C3> set rt:0
[2026-08-08 20:29:37.528 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:37.528 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:37.628 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:37.628 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:37.678 UTC] [V] OFSCtrl [/var/local/solajithome/function/output_fluctuation_suppression/batt_data] write success.
[2026-08-08 20:29:37.728 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:37.728 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:37.828 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:37.828 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:37.928 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:37.928 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:38.028 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:38.028 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:38.129 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:38.129 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:38.228 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:38.228 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:38.328 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:38.328 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:38.328 UTC] [V] OFSCtrl Control charge discharge proc start.
[2026-08-08 20:29:38.329 UTC] [V] OFSCtrl CHG 20 p_th(t):-1109.900000 = p_th_old_:-1100.000000 + lev_cd_:-0.300000 * (total_pcs_capacity_:99000.000000 * cof_spec_:2.000000 / 60 * (time_threshold_renew:10.000000 * 10)), min:-1100.000000, max:119300.000000
[2026-08-08 20:29:38.329 UTC] [V] OFSCtrl CHG 21 batt_w:247.869526 = old:251.307026 +  kp:0.550000 * e:-6.250000 + ki:0.000000 * sume:9163043.200228 + kd:0.040000 * (e:-6.250000 - e1:-6.250000)
[2026-08-08 20:29:38.329 UTC] [V] OFSCtrl CHG 29 q:2.000000, mod(round):0.000000
[2026-08-08 20:29:38.330 UTC] [D] OFSCtrl battery ctrl val:0.500000
[2026-08-08 20:29:38.330 UTC] [V] 485ChCtl <C3> battery limit on [2.000000,] request.
[2026-08-08 20:29:38.330 UTC] [V] OFSCtrl Control charge discharge proc:01->02->BATT_CHK->03->04->05->06->07->10->11->20->21->22->23->24->25->27->28->29->30->31->32->33->34
[2026-08-08 20:29:38.428 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:38.428 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:38.430 UTC] [V] 485ChCtl <C3> battery send request.1
[2026-08-08 20:29:38.430 UTC] [D] VarInf Limit_Bat rt[2]set val[2] set rate[0.400000] value100[500] value-100[-500]
[2026-08-08 20:29:38.432 UTC] [D] 485AcReq <C3:01> PutOStream [6][0f000001000000090110278e0001020002]
[2026-08-08 20:29:38.528 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:38.528 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:38.587 UTC] [V] 485DevCtl <C3:01> AnalyzeResponseData proc restart cnt:360498 UPRstat:0
[2026-08-08 20:29:38.589 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-08 20:29:38.590 UTC] [D] 485DevCtl <C3:01> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-08 20:29:38.590 UTC] [D] 485DevCtl <C3:01> ResCnd OperationId [6] IsNormal[1] 
[2026-08-08 20:29:38.591 UTC] [V] 485DevCtl <C3:01> device_type:Battery
[2026-08-08 20:29:38.593 UTC] [V] 485ChCtl <C3> set rt:0
[2026-08-08 20:29:38.628 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:38.628 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:38.678 UTC] [V] OFSCtrl [/var/local/solajithome/function/output_fluctuation_suppression/batt_data] write success.
[2026-08-08 20:29:38.728 UTC] [V] OFSCtrl limit chk 400 < 800 < [1074->1074] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:38.728 UTC] [V] OFSCtrl angif value:1074 power_val_:-1162.500000
[2026-08-08 20:29:38.828 UTC] [V] OFSCtrl limit chk 400 < 800 < [1071->1071] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:38.828 UTC] [V] OFSCtrl angif value:1071 power_val_:-1368.750000
[2026-08-08 20:29:38.928 UTC] [V] OFSCtrl limit chk 400 < 800 < [1072->1072] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:38.928 UTC] [V] OFSCtrl angif value:1072 power_val_:-1300.000000
[2026-08-08 20:29:39.028 UTC] [V] OFSCtrl limit chk 400 < 800 < [1072->1072] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:39.028 UTC] [V] OFSCtrl angif value:1072 power_val_:-1300.000000
[2026-08-08 20:29:39.127 UTC] [V] OFSCtrl limit chk 400 < 800 < [1072->1072] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:39.128 UTC] [V] OFSCtrl angif value:1072 power_val_:-1300.000000
[2026-08-08 20:29:39.228 UTC] [V] OFSCtrl limit chk 400 < 800 < [1072->1072] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:39.228 UTC] [V] OFSCtrl angif value:1072 power_val_:-1300.000000
[2026-08-08 20:29:39.328 UTC] [V] OFSCtrl limit chk 400 < 800 < [1072->1072] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:39.328 UTC] [V] OFSCtrl angif value:1072 power_val_:-1300.000000
[2026-08-08 20:29:39.328 UTC] [V] OFSCtrl Control charge discharge proc start.
[2026-08-08 20:29:39.328 UTC] [V] OFSCtrl CHG 20 p_th(t):-1109.900000 = p_th_old_:-1100.000000 + lev_cd_:-0.300000 * (total_pcs_capacity_:99000.000000 * cof_spec_:2.000000 / 60 * (time_threshold_renew:10.000000 * 10)), min:-1100.000000, max:119300.000000
[2026-08-08 20:29:39.329 UTC] [V] OFSCtrl CHG 21 batt_w:366.119526 = old:247.869526 +  kp:0.550000 * e:200.000000 + ki:0.000000 * sume:9163243.200228 + kd:0.040000 * (e:200.000000 - e1:-6.250000)
[2026-08-08 20:29:39.329 UTC] [V] OFSCtrl CHG 29 q:3.000000, mod(round):1.000000
[2026-08-08 20:29:39.329 UTC] [D] OFSCtrl battery ctrl val:0.700000
[2026-08-08 20:29:39.330 UTC] [V] 485ChCtl <C3> battery limit on [4.000000,] request.
[2026-08-08 20:29:39.330 UTC] [V] OFSCtrl Control charge discharge proc:01->02->BATT_CHK->03->04->05->06->07->10->11->20->21->22->23->24->25->27->28->29->30->31->32->33->34
[2026-08-08 20:29:39.428 UTC] [V] OFSCtrl limit chk 400 < 800 < [1072->1072] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:39.428 UTC] [V] OFSCtrl angif value:1072 power_val_:-1300.000000
[2026-08-08 20:29:39.429 UTC] [V] 485ChCtl <C3> battery send request.1
[2026-08-08 20:29:39.430 UTC] [D] VarInf Limit_Bat rt[2]set val[4] set rate[0.800000] value100[500] value-100[-500]
[2026-08-08 20:29:39.431 UTC] [D] 485AcReq <C3:01> PutOStream [6][0f000001000000090110278e0001020004]
[2026-08-08 20:29:39.527 UTC] [V] OFSCtrl limit chk 400 < 800 < [1072->1072] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:39.528 UTC] [V] OFSCtrl angif value:1072 power_val_:-1300.000000
[2026-08-08 20:29:39.587 UTC] [V] 485DevCtl <C3:01> AnalyzeResponseData proc restart cnt:360499 UPRstat:0
[2026-08-08 20:29:39.589 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-08 20:29:39.591 UTC] [D] 485DevCtl <C3:01> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-08 20:29:39.591 UTC] [D] 485DevCtl <C3:01> ResCnd OperationId [6] IsNormal[1] 
[2026-08-08 20:29:39.591 UTC] [V] 485DevCtl <C3:01> device_type:Battery
[2026-08-08 20:29:39.591 UTC] [V] 485ChCtl <C3> set rt:0
[2026-08-08 20:29:39.627 UTC] [V] OFSCtrl limit chk 400 < 800 < [1072->1072] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:39.628 UTC] [V] OFSCtrl angif value:1072 power_val_:-1300.000000
[2026-08-08 20:29:39.678 UTC] [V] OFSCtrl [/var/local/solajithome/function/output_fluctuation_suppression/batt_data] write success.
[2026-08-08 20:29:39.727 UTC] [V] OFSCtrl limit chk 400 < 800 < [1072->1072] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:39.728 UTC] [V] OFSCtrl angif value:1072 power_val_:-1300.000000
[2026-08-08 20:29:39.827 UTC] [V] OFSCtrl limit chk 400 < 800 < [1072->1072] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:39.828 UTC] [V] OFSCtrl angif value:1072 power_val_:-1300.000000
[2026-08-08 20:29:39.927 UTC] [V] OFSCtrl limit chk 400 < 800 < [1072->1072] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:39.928 UTC] [V] OFSCtrl angif value:1072 power_val_:-1300.000000
[2026-08-08 20:29:40.027 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:40.028 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:40.127 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:40.128 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:40.228 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:40.228 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:40.327 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:40.328 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:40.328 UTC] [V] OFSCtrl Control charge discharge proc start.
[2026-08-08 20:29:40.328 UTC] [V] OFSCtrl CHG 20 p_th(t):-1109.900000 = p_th_old_:-1100.000000 + lev_cd_:-0.300000 * (total_pcs_capacity_:99000.000000 * cof_spec_:2.000000 / 60 * (time_threshold_renew:10.000000 * 10)), min:-1100.000000, max:119300.000000
[2026-08-08 20:29:40.328 UTC] [V] OFSCtrl CHG 21 batt_w:354.432026 = old:366.119526 +  kp:0.550000 * e:-6.250000 + ki:0.000000 * sume:9163236.950228 + kd:0.040000 * (e:-6.250000 - e1:200.000000)
[2026-08-08 20:29:40.329 UTC] [V] OFSCtrl CHG 29 q:3.000000, mod(round):1.000000
[2026-08-08 20:29:40.329 UTC] [D] OFSCtrl battery ctrl val:0.700000
[2026-08-08 20:29:40.329 UTC] [V] 485ChCtl <C3> battery limit on [4.000000,] request.
[2026-08-08 20:29:40.329 UTC] [V] OFSCtrl Control charge discharge proc:01->02->BATT_CHK->03->04->05->06->07->10->11->20->21->22->23->24->25->27->28->29->30->31->32->33->34
[2026-08-08 20:29:40.330 UTC] [V] 485ChCtl <C3> battery send request.1
[2026-08-08 20:29:40.330 UTC] [D] VarInf Limit_Bat rt[2]set val[4] set rate[0.800000] value100[500] value-100[-500]
[2026-08-08 20:29:40.332 UTC] [D] 485AcReq <C3:01> PutOStream [6][0f000001000000090110278e0001020004]
[2026-08-08 20:29:40.393 UTC] [V] 485DevCtl <C1:01> device_type:Irr-Meter
[2026-08-08 20:29:40.393 UTC] [V] 485DevCtl <C1:01> device_type:Irr-Meter
[2026-08-08 20:29:40.393 UTC] [V] 485ChCtl <C1> fixed cycle Irr-Meter
[2026-08-08 20:29:40.393 UTC] [V] 485DevCtl <C1:01> Dev not PCS IsNeedToChangeOControlState
[2026-08-08 20:29:40.394 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :1
[2026-08-08 20:29:40.394 UTC] [V] 485ChCtl <C1> send request:Irr01
[2026-08-08 20:29:40.395 UTC] [D] 485AcReq <C1:01> PutOStream [1][080001040000000271cb]
[2026-08-08 20:29:40.432 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:40.432 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:40.477 UTC] [V] 485DevCtl <C3:01> AnalyzeResponseData proc restart cnt:360499 UPRstat:0
[2026-08-08 20:29:40.479 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-08 20:29:40.480 UTC] [D] 485DevCtl <C3:01> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-08 20:29:40.480 UTC] [D] 485DevCtl <C3:01> ResCnd OperationId [6] IsNormal[1] 
[2026-08-08 20:29:40.480 UTC] [V] 485DevCtl <C3:01> device_type:Battery
[2026-08-08 20:29:40.481 UTC] [V] 485ChCtl <C3> set rt:0
[2026-08-08 20:29:40.527 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:40.527 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:40.610 UTC] [V] 485ChCtl <C2> StartDeviceCommunicationForOutputFluctuationSuppressionControlBroadcast 4 cnt:3605052, monitor_cnt:50, bc_elapsed:3605052, min:10, max:40
[2026-08-08 20:29:40.610 UTC] [V] OFSCtrl /var/local/solajithome/function/output_fluctuation_suppression/state is exist:0
[2026-08-08 20:29:40.610 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :10
[2026-08-08 20:29:40.611 UTC] [V] 485ChCtl <C2> send request:Sungrow08
[2026-08-08 20:29:40.612 UTC] [D] 485AcReq <C2:01> PutOStream [10][0800010413d80002f574]
[2026-08-08 20:29:40.627 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:40.627 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:40.679 UTC] [V] OFSCtrl [/var/local/solajithome/function/output_fluctuation_suppression/batt_data] write success.
[2026-08-08 20:29:40.722 UTC] [V] 485DevCtl <C1:01> AnalyzeResponseData proc restart cnt:360501 UPRstat:0
[2026-08-08 20:29:40.722 UTC] [V] Res no response condition. set normal condition.
[2026-08-08 20:29:40.722 UTC] [D] 485DevCtl <C1:01> RcvDat status[2] len[9] [010404000002013b24]
[2026-08-08 20:29:40.723 UTC] [D] 485DevCtl <C1:01> ResCnd OperationId [1] IsNormal[1] 
[2026-08-08 20:29:40.723 UTC] [V] OFSCtrl Rcv set flux_of_solar:0.000000
[2026-08-08 20:29:40.723 UTC] [V] 485DevCtl <C1:01> [01][401006][0.000000][1][W/m2]
[2026-08-08 20:29:40.723 UTC] [V] SummDat SetVrmValue dev_id:1 val:0.000000 sc:3
[2026-08-08 20:29:40.724 UTC] [V] OCMgr SetMeterValue PhId:0101, branchNo:01, valueId:401006, value:0.000000, scaleFactor:1, devId:1
[2026-08-08 20:29:40.724 UTC] [V] 485DevCtl <C1:01> [01][421005][263.000000][1][℃]
[2026-08-08 20:29:40.726 UTC] [V] SummDat SetVrmValue dev_id:1 val:26300.000000 sc:3
[2026-08-08 20:29:40.728 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:40.728 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:40.730 UTC] [V] 485ChCtl <C3> StartDeviceCommunicationForOutputFluctuationSuppressionControlBroadcast 4 cnt:3605053, monitor_cnt:50, bc_elapsed:3605053, min:10, max:40
[2026-08-08 20:29:40.730 UTC] [V] OFSCtrl /var/local/solajithome/function/output_fluctuation_suppression/state is exist:0
[2026-08-08 20:29:40.730 UTC] [V] 485DevCtl <C3:01> Dev not PCS IsNeedToChangeOControlState
[2026-08-08 20:29:40.730 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :5
[2026-08-08 20:29:40.731 UTC] [V] 485ChCtl <C3> send request:Sungrow11
[2026-08-08 20:29:40.732 UTC] [D] 485AcReq <C3:01> PutOStream [5][0c00000100000006010469780001]
[2026-08-08 20:29:40.735 UTC] [V] OCMgr SetMeterValue PhId:0101, branchNo:01, valueId:421005, value:263.000000, scaleFactor:1, devId:1
[2026-08-08 20:29:40.740 UTC] [V] 485DevCtl <C1:01> device_type:Irr-Meter
[2026-08-08 20:29:40.741 UTC] [V] OFSCtrl Irr-Meter received.
[2026-08-08 20:29:40.753 UTC] [V] 485ChCtl <C1> set rt:0
[2026-08-08 20:29:40.755 UTC] [V] 485DevCtl <C1:01> device_type:Irr-Meter
[2026-08-08 20:29:40.792 UTC] [V] 485DevCtl <C1:04> device_type:CO-Meter
[2026-08-08 20:29:40.793 UTC] [V] 485DevCtl <C1:04> device_type:CO-Meter
[2026-08-08 20:29:40.793 UTC] [V] 485ChCtl <C1> fixed cycle CO-Meter
[2026-08-08 20:29:40.793 UTC] [V] 485DevCtl <C1:04> Dev not PCS IsNeedToChangeOControlState
[2026-08-08 20:29:40.793 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :1
[2026-08-08 20:29:40.794 UTC] [V] 485ChCtl <C1> send request:omron05
[2026-08-08 20:29:40.796 UTC] [D] 485AcReq <C1:04> PutOStream [1][0800040300030014b590]
[2026-08-08 20:29:40.828 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:40.828 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:40.857 UTC] [V] 485DevCtl <C3:01> AnalyzeResponseData proc restart cnt:360500 UPRstat:0
[2026-08-08 20:29:40.859 UTC] [D] 485DevCtl <C3:01> RcvDat status[0] len[11] [0001000000050104020128]
[2026-08-08 20:29:40.859 UTC] [D] 485DevCtl <C3:01> ResCnd OperationId [5] IsNormal[1]  ConditionType [lggrdev:Normal] Action[-1]
[2026-08-08 20:29:40.860 UTC] [V] 485DevCtl <C3:01> [01][121005][296.000000][1][℃]
[2026-08-08 20:29:40.860 UTC] [V] SummDat SetVrmValue dev_id:9 val:29600.000000 sc:3
[2026-08-08 20:29:40.860 UTC] [V] OCMgr SetMeterValue PhId:0301, branchNo:01, valueId:121005, value:296.000000, scaleFactor:1, devId:9
[2026-08-08 20:29:40.861 UTC] [V] 485DevCtl <C3:01> device_type:Battery
[2026-08-08 20:29:40.862 UTC] [V] 485ChCtl <C3> set rt:0
[2026-08-08 20:29:40.873 UTC] [D] 485ChCtl <C3> monitoring dev All Send
[2026-08-08 20:29:40.928 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:40.928 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:40.941 UTC] [V] Res no response condition. set normal condition.
[2026-08-08 20:29:40.942 UTC] [D] 485DevCtl <C2:01> RcvDat status[2] len[9] [01040400100000fa41]
[2026-08-08 20:29:40.942 UTC] [D] 485DevCtl <C2:01> ResCnd OperationId [10] IsNormal[1] 
[2026-08-08 20:29:40.943 UTC] [V] 485DevCtl <C2:01> device_type:PV-PCS
[2026-08-08 20:29:40.944 UTC] [V] 485ChCtl <C2> set rt:0
[2026-08-08 20:29:41.010 UTC] [V] 485ChCtl <C2> StartDeviceCommunicationForOutputFluctuationSuppressionControlBroadcast 4 cnt:3605056, monitor_cnt:54, bc_elapsed:3605056, min:10, max:40
[2026-08-08 20:29:41.010 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :1
[2026-08-08 20:29:41.011 UTC] [V] 485ChCtl <C2> send request:Sungrow08
[2026-08-08 20:29:41.012 UTC] [D] 485AcReq <C2:02> PutOStream [1][08000204138a0024d54c]
[2026-08-08 20:29:41.028 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:41.028 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:41.128 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:41.128 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:41.197 UTC] [V] 485DevCtl <C1:04> AnalyzeResponseData proc restart cnt:360500 UPRstat:0
[2026-08-08 20:29:41.198 UTC] [V] Res no response condition. set normal condition.
[2026-08-08 20:29:41.199 UTC] [D] 485DevCtl <C1:04> RcvDat status[2] len[45] [04032800002248000017fa0000181dffffffe400000258ffffe818ffffffc3ffffaf1cffffff3100121a8154f4]
[2026-08-08 20:29:41.199 UTC] [D] 485DevCtl <C1:04> ResCnd OperationId [1] IsNormal[1] 
[2026-08-08 20:29:41.201 UTC] [V] OFSCtrl Rcv set p_co:-610.000000, p_co_old:-590.000000
[2026-08-08 20:29:41.202 UTC] [V] 485DevCtl <C1:04> [01][601260][-61.000000][2][kW]
[2026-08-08 20:29:41.202 UTC] [V] SummDat SetVrmValue dev_id:4 val:-610.000000 sc:3
[2026-08-08 20:29:41.209 UTC] [V] OCMgr SetMeterValue PhId:0104, branchNo:01, valueId:601260, value:-61.000000, scaleFactor:2, devId:4
[2026-08-08 20:29:41.209 UTC] [V] 485DevCtl <C1:04> [01][603260][1186433.000000][1][kWh]
[2026-08-08 20:29:41.209 UTC] [V] SummDat SetVrmValue dev_id:4 val:1186433.000000 sc:1
[2026-08-08 20:29:41.210 UTC] [V] OCMgr SetMeterValue PhId:0104, branchNo:01, valueId:603260, value:1186433.000000, scaleFactor:1, devId:4
[2026-08-08 20:29:41.218 UTC] [V] 485DevCtl <C1:04> device_type:CO-Meter
[2026-08-08 20:29:41.220 UTC] [V] OFSCtrl km50 received.
[2026-08-08 20:29:41.225 UTC] [V] OFSCtrl omron05_local_date :2026/08/09 ? 2026/08/09
[2026-08-08 20:29:41.225 UTC] [V] OFSCtrl omron05_local_time :2026/08/09 05 ? 2026/08/09 05
[2026-08-08 20:29:41.225 UTC] [V] OFSCtrl out of control time.
[2026-08-08 20:29:41.225 UTC] [V] OFSCtrl Control pv-pcs proc start.
[2026-08-08 20:29:41.226 UTC] [V] OFSCtrl NOD_month:-1664.000000 = (NOD_month:306 - ((nod_max_/30):23.333333 * (cnt-1):25) * (30/cnt):6.000000 
[2026-08-08 20:29:41.226 UTC] [V] OFSCtrl PCS ratio_month:232.646617 = -k_inhibition_ratio_month:-0.097744 * NOD_month:-1664.000000 + inhibition_ratio_max:70
[2026-08-08 20:29:41.226 UTC] [V] OFSCtrl PCS 05 inhibition_ratio:70.000000 = max(ratio_min:5, min(ratio:70, ratio_hour:70.000000, ratio_day:70.000000, ratio_month:232.646617))
[2026-08-08 20:29:41.226 UTC] [D] OFSCtrl pv-pcs ctrl val:0.000000 old:0.000000
[2026-08-08 20:29:41.227 UTC] [V] OCHisDB set rate:0 t_rate:0 cnt:55
[2026-08-08 20:29:41.227 UTC] [V] 485ChCtl <C2> pv-pcs limit on [0.000000] request.
[2026-08-08 20:29:41.227 UTC] [V] OFSCtrl Control pv-pcs proc:BATT_CHK->01->02->03->04->05->06->07->09->09->10->11->12
[2026-08-08 20:29:41.227 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:41.228 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:41.227 UTC] [V] OFSCtrl Nod calc proc start.
[2026-08-08 20:29:41.248 UTC] [V] OFSCtrl ProcNodCountCalculation culc nod skip stop:0, pause:0, ctl_time:0
[2026-08-08 20:29:41.256 UTC] [V] OFSCtrl update p_co_old:-610.000000
[2026-08-08 20:29:41.256 UTC] [V] OFSCtrl Nod calc proc:
[2026-08-08 20:29:41.257 UTC] [V] 485ChCtl <C1> set rt:0
[2026-08-08 20:29:41.257 UTC] [V] 485DevCtl <C1:04> device_type:CO-Meter
[2026-08-08 20:29:41.327 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:41.328 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:41.328 UTC] [V] OFSCtrl Control charge discharge proc start.
[2026-08-08 20:29:41.328 UTC] [V] OFSCtrl CHG 20 p_th(t):-1109.900000 = p_th_old_:-1100.000000 + lev_cd_:-0.300000 * (total_pcs_capacity_:99000.000000 * cof_spec_:2.000000 / 60 * (time_threshold_renew:10.000000 * 10)), min:-1100.000000, max:119300.000000
[2026-08-08 20:29:41.328 UTC] [V] OFSCtrl CHG 21 batt_w:350.994526 = old:354.432026 +  kp:0.550000 * e:-6.250000 + ki:0.000000 * sume:9163230.700228 + kd:0.040000 * (e:-6.250000 - e1:-6.250000)
[2026-08-08 20:29:41.329 UTC] [V] OFSCtrl CHG 29 q:3.000000, mod(round):1.000000
[2026-08-08 20:29:41.329 UTC] [D] OFSCtrl battery ctrl val:0.700000
[2026-08-08 20:29:41.329 UTC] [V] 485ChCtl <C3> battery limit on [4.000000,] request.
[2026-08-08 20:29:41.329 UTC] [V] OFSCtrl Control charge discharge proc:01->02->BATT_CHK->03->04->05->06->07->10->11->20->21->22->23->24->25->27->28->29->30->31->32->33->34
[2026-08-08 20:29:41.330 UTC] [V] 485ChCtl <C3> battery send request.1
[2026-08-08 20:29:41.330 UTC] [D] VarInf Limit_Bat rt[2]set val[4] set rate[0.800000] value100[500] value-100[-500]
[2026-08-08 20:29:41.332 UTC] [D] 485AcReq <C3:01> PutOStream [6][0f000001000000090110278e0001020004]
[2026-08-08 20:29:41.419 UTC] [V] Res no response condition. set normal condition.
[2026-08-08 20:29:41.423 UTC] [D] 485DevCtl <C2:02> RcvDat status[2] len[77] [0204480000024a0001171f000000000000000000000000000000000000000000000000000000000000000000000000ffffffffffffffffffffffff000000000000000000000000000014008841]
[2026-08-08 20:29:41.423 UTC] [D] 485DevCtl <C2:02> ResCnd OperationId [1] IsNormal[1] 
[2026-08-08 20:29:41.427 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:41.427 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:41.428 UTC] [V] 485DevCtl <C2:02> [01][115202][0.000000][1][kWh]
[2026-08-08 20:29:41.429 UTC] [V] SummDat SetVrmValue dev_id:8 val:0.000000 sc:1
[2026-08-08 20:29:41.434 UTC] [V] OCMgr SetMeterValue PhId:0202, branchNo:01, valueId:115202, value:0.000000, scaleFactor:1, devId:8
[2026-08-08 20:29:41.438 UTC] [V] 485DevCtl <C2:02> [01][113202][66122.000000][0][kWh]
[2026-08-08 20:29:41.439 UTC] [V] SummDat SetVrmValue dev_id:8 val:66122.000000 sc:0
[2026-08-08 20:29:41.443 UTC] [V] OCMgr SetMeterValue PhId:0202, branchNo:01, valueId:113202, value:66122.000000, scaleFactor:0, devId:8
[2026-08-08 20:29:41.446 UTC] [V] 485DevCtl <C2:02> [01][121005][0.000000][1][℃]
[2026-08-08 20:29:41.446 UTC] [V] SummDat SetVrmValue dev_id:8 val:0.000000 sc:3
[2026-08-08 20:29:41.449 UTC] [V] OCMgr SetMeterValue PhId:0202, branchNo:01, valueId:121005, value:0.000000, scaleFactor:1, devId:8
[2026-08-08 20:29:41.452 UTC] [V] 485DevCtl <C2:02> [01][101100][0.000000][1][V]
[2026-08-08 20:29:41.453 UTC] [V] SummDat SetVrmValue dev_id:8 val:0.000000 sc:3
[2026-08-08 20:29:41.458 UTC] [V] OCMgr SetMeterValue PhId:0202, branchNo:01, valueId:101100, value:0.000000, scaleFactor:1, devId:8
[2026-08-08 20:29:41.464 UTC] [V] 485DevCtl <C2:02> [01][101101][0.000000][1][A]
[2026-08-08 20:29:41.464 UTC] [V] SummDat SetVrmValue dev_id:8 val:0.000000 sc:3
[2026-08-08 20:29:41.468 UTC] [V] OCMgr SetMeterValue PhId:0202, branchNo:01, valueId:101101, value:0.000000, scaleFactor:1, devId:8
[2026-08-08 20:29:41.470 UTC] [V] 485DevCtl <C2:02> [02][101100][0.000000][1][V]
[2026-08-08 20:29:41.471 UTC] [V] SummDat SetVrmValue dev_id:8 val:0.000000 sc:3
[2026-08-08 20:29:41.473 UTC] [V] OCMgr SetMeterValue PhId:0202, branchNo:02, valueId:101100, value:0.000000, scaleFactor:1, devId:8
[2026-08-08 20:29:41.475 UTC] [V] 485DevCtl <C2:02> [02][101101][0.000000][1][A]
[2026-08-08 20:29:41.477 UTC] [V] 485DevCtl <C3:01> AnalyzeResponseData proc restart cnt:360500 UPRstat:0
[2026-08-08 20:29:41.480 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-08 20:29:41.480 UTC] [D] 485DevCtl <C3:01> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-08 20:29:41.480 UTC] [D] 485DevCtl <C3:01> ResCnd OperationId [6] IsNormal[1] 
[2026-08-08 20:29:41.481 UTC] [V] 485DevCtl <C3:01> device_type:Battery
[2026-08-08 20:29:41.481 UTC] [V] 485ChCtl <C3> set rt:0
[2026-08-08 20:29:41.482 UTC] [V] SummDat SetVrmValue dev_id:8 val:0.000000 sc:3
[2026-08-08 20:29:41.485 UTC] [V] OCMgr SetMeterValue PhId:0202, branchNo:02, valueId:101101, value:0.000000, scaleFactor:1, devId:8
[2026-08-08 20:29:41.488 UTC] [V] 485DevCtl <C2:02> [03][101100][0.000000][1][V]
[2026-08-08 20:29:41.489 UTC] [V] SummDat SetVrmValue dev_id:8 val:0.000000 sc:3
[2026-08-08 20:29:41.492 UTC] [V] OCMgr SetMeterValue PhId:0202, branchNo:03, valueId:101100, value:0.000000, scaleFactor:1, devId:8
[2026-08-08 20:29:41.496 UTC] [V] 485DevCtl <C2:02> [03][101101][0.000000][1][A]
[2026-08-08 20:29:41.497 UTC] [V] SummDat SetVrmValue dev_id:8 val:0.000000 sc:3
[2026-08-08 20:29:41.502 UTC] [V] OCMgr SetMeterValue PhId:0202, branchNo:03, valueId:101101, value:0.000000, scaleFactor:1, devId:8
[2026-08-08 20:29:41.504 UTC] [V] 485DevCtl <C2:02> [01][101102][0.000000][0][W]
[2026-08-08 20:29:41.506 UTC] [V] SummDat SetVrmValue dev_id:8 val:0.000000 sc:3
[2026-08-08 20:29:41.510 UTC] [V] OCMgr SetMeterValue PhId:0202, branchNo:01, valueId:101102, value:0.000000, scaleFactor:0, devId:8
[2026-08-08 20:29:41.514 UTC] [V] 485DevCtl <C2:02> [01][111200][0.000000][1][V]
[2026-08-08 20:29:41.517 UTC] [V] SummDat SetVrmValue dev_id:8 val:0.000000 sc:3
[2026-08-08 20:29:41.520 UTC] [V] OCMgr SetMeterValue PhId:0202, branchNo:01, valueId:111200, value:0.000000, scaleFactor:1, devId:8
[2026-08-08 20:29:41.523 UTC] [V] 485DevCtl <C2:02> [02][111200][0.000000][1][V]
[2026-08-08 20:29:41.524 UTC] [V] SummDat SetVrmValue dev_id:8 val:0.000000 sc:3
[2026-08-08 20:29:41.528 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:41.528 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:41.529 UTC] [V] OCMgr SetMeterValue PhId:0202, branchNo:02, valueId:111200, value:0.000000, scaleFactor:1, devId:8
[2026-08-08 20:29:41.538 UTC] [V] 485DevCtl <C2:02> [03][111200][0.000000][1][V]
[2026-08-08 20:29:41.539 UTC] [V] SummDat SetVrmValue dev_id:8 val:0.000000 sc:3
[2026-08-08 20:29:41.539 UTC] [V] OCMgr SetMeterValue PhId:0202, branchNo:03, valueId:111200, value:0.000000, scaleFactor:1, devId:8
[2026-08-08 20:29:41.539 UTC] [V] 485DevCtl <C2:02> [01][111201][0.000000][1][A]
[2026-08-08 20:29:41.539 UTC] [V] SummDat SetVrmValue dev_id:8 val:0.000000 sc:3
[2026-08-08 20:29:41.540 UTC] [V] OCMgr SetMeterValue PhId:0202, branchNo:01, valueId:111201, value:0.000000, scaleFactor:1, devId:8
[2026-08-08 20:29:41.540 UTC] [V] 485DevCtl <C2:02> [02][111201][0.000000][1][A]
[2026-08-08 20:29:41.540 UTC] [V] SummDat SetVrmValue dev_id:8 val:0.000000 sc:3
[2026-08-08 20:29:41.540 UTC] [V] OCMgr SetMeterValue PhId:0202, branchNo:02, valueId:111201, value:0.000000, scaleFactor:1, devId:8
[2026-08-08 20:29:41.541 UTC] [V] 485DevCtl <C2:02> [03][111201][0.000000][1][A]
[2026-08-08 20:29:41.541 UTC] [V] SummDat SetVrmValue dev_id:8 val:0.000000 sc:3
[2026-08-08 20:29:41.541 UTC] [V] OCMgr SetMeterValue PhId:0202, branchNo:03, valueId:111201, value:0.000000, scaleFactor:1, devId:8
[2026-08-08 20:29:41.541 UTC] [V] 485DevCtl <C2:02> [01][111202][0.000000][0][W]
[2026-08-08 20:29:41.541 UTC] [V] SummDat SetVrmValue dev_id:8 val:0.000000 sc:3
[2026-08-08 20:29:41.541 UTC] [V] OCMgr SetMeterValue PhId:0202, branchNo:01, valueId:111202, value:0.000000, scaleFactor:0, devId:8
[2026-08-08 20:29:41.542 UTC] [V] 485DevCtl <C2:02> [01][111203][0.000000][0][var]
[2026-08-08 20:29:41.542 UTC] [V] SummDat SetVrmValue dev_id:8 val:0.000000 sc:3
[2026-08-08 20:29:41.542 UTC] [V] OCMgr SetMeterValue PhId:0202, branchNo:01, valueId:111203, value:0.000000, scaleFactor:0, devId:8
[2026-08-08 20:29:41.568 UTC] [V] 485DevCtl <C2:02> [01][121007][0.000000][3][]
[2026-08-08 20:29:41.569 UTC] [V] SummDat SetVrmValue dev_id:8 val:0.000000 sc:3
[2026-08-08 20:29:41.574 UTC] [V] OCMgr SetMeterValue PhId:0202, branchNo:01, valueId:121007, value:0.000000, scaleFactor:3, devId:8
[2026-08-08 20:29:41.579 UTC] [V] 485DevCtl <C2:02> [01][131006][0.000000][1][Hz]
[2026-08-08 20:29:41.584 UTC] [V] SummDat SetVrmValue dev_id:8 val:0.000000 sc:3
[2026-08-08 20:29:41.591 UTC] [V] OCMgr SetMeterValue PhId:0202, branchNo:01, valueId:131006, value:0.000000, scaleFactor:1, devId:8
[2026-08-08 20:29:41.591 UTC] [V] 485DevCtl <C2:02> [01][114202][66122.000000][0][kWh]
[2026-08-08 20:29:41.592 UTC] [V] SummDat SetVrmValue dev_id:8 val:66122000.000000 sc:3
[2026-08-08 20:29:41.592 UTC] [V] OCMgr SetMeterValue PhId:0202, branchNo:01, valueId:114202, value:66122.000000, scaleFactor:0, devId:8
[2026-08-08 20:29:41.592 UTC] [V] 485DevCtl <C2:02> device_type:PV-PCS
[2026-08-08 20:29:41.593 UTC] [V] 485DevCtl <C2:02> set2 StatusCode[010100] DeviceName[] DeviceNumber[]
[2026-08-08 20:29:41.625 UTC] [V] 485ChCtl <C2> set rt:0
[2026-08-08 20:29:41.626 UTC] [D] 485ChCtl <C2> monitoring dev All Send
[2026-08-08 20:29:41.628 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:41.628 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:41.679 UTC] [V] OFSCtrl [/var/local/solajithome/function/output_fluctuation_suppression/batt_data] write success.
[2026-08-08 20:29:41.709 UTC] [V] 485ChCtl <C2> pv-pcs send request.
[2026-08-08 20:29:41.710 UTC] [D] VarInf update ofs_rate:0.000000
[2026-08-08 20:29:41.710 UTC] [V] VarInf LimitSet rt[2] val[170] key[ValueOn]
[2026-08-08 20:29:41.710 UTC] [D] VarInf output_mode:8
[2026-08-08 20:29:41.710 UTC] [D] VarInf update ofs_rate:0.000000
[2026-08-08 20:29:41.710 UTC] [D] VarInf Limit setRate[0.000000] rate[0.000000] value100[1000.000000] value0[0.000000]
[2026-08-08 20:29:41.710 UTC] [V] 485DevCtl <C2:01> ChangeOutputRateToDevice rate:0.000000 set_rate1
[2026-08-08 20:29:41.710 UTC] [D] VarInf Limit rt[2] int_set_rate[1] server_rate[0.000000] rated_output[100.000000] solar_battery_power[100.000000]
[2026-08-08 20:29:41.712 UTC] [D] 485AcReq <C2:01> PutOStreamForBc [3][0d000010138e00020400aa0001466f]
[2026-08-08 20:29:41.728 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:41.728 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:41.827 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:41.828 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:41.927 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:41.927 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:42.005 UTC] [V] 485ChCtl <C2> set rt:0
[2026-08-08 20:29:42.027 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:42.027 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:42.127 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:42.127 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:42.227 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:42.227 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:42.327 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:42.327 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:42.327 UTC] [V] OFSCtrl Control charge discharge proc start.
[2026-08-08 20:29:42.328 UTC] [V] OFSCtrl CHG 20 p_th(t):-1109.900000 = p_th_old_:-1100.000000 + lev_cd_:-0.300000 * (total_pcs_capacity_:99000.000000 * cof_spec_:2.000000 / 60 * (time_threshold_renew:10.000000 * 10)), min:-1100.000000, max:119300.000000
[2026-08-08 20:29:42.328 UTC] [V] OFSCtrl CHG 21 batt_w:347.557026 = old:350.994526 +  kp:0.550000 * e:-6.250000 + ki:0.000000 * sume:9163224.450228 + kd:0.040000 * (e:-6.250000 - e1:-6.250000)
[2026-08-08 20:29:42.328 UTC] [V] OFSCtrl CHG 29 q:3.000000, mod(round):0.000000
[2026-08-08 20:29:42.329 UTC] [D] OFSCtrl battery ctrl val:0.700000
[2026-08-08 20:29:42.329 UTC] [V] 485ChCtl <C3> battery limit on [3.000000,] request.
[2026-08-08 20:29:42.329 UTC] [V] OFSCtrl Control charge discharge proc:01->02->BATT_CHK->03->04->05->06->07->10->11->20->21->22->23->24->25->27->28->29->30->31->32->33->34
[2026-08-08 20:29:42.330 UTC] [V] 485ChCtl <C3> battery send request.1
[2026-08-08 20:29:42.331 UTC] [D] VarInf Limit_Bat rt[2]set val[3] set rate[0.600000] value100[500] value-100[-500]
[2026-08-08 20:29:42.332 UTC] [D] 485AcReq <C3:01> PutOStream [6][0f000001000000090110278e0001020003]
[2026-08-08 20:29:42.428 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:42.428 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:42.487 UTC] [V] 485DevCtl <C3:01> AnalyzeResponseData proc restart cnt:360501 UPRstat:0
[2026-08-08 20:29:42.489 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-08 20:29:42.490 UTC] [D] 485DevCtl <C3:01> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-08 20:29:42.490 UTC] [D] 485DevCtl <C3:01> ResCnd OperationId [6] IsNormal[1] 
[2026-08-08 20:29:42.491 UTC] [V] 485DevCtl <C3:01> device_type:Battery
[2026-08-08 20:29:42.491 UTC] [V] 485ChCtl <C3> set rt:0
[2026-08-08 20:29:42.527 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:42.528 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:42.627 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:42.628 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:42.679 UTC] [V] OFSCtrl [/var/local/solajithome/function/output_fluctuation_suppression/batt_data] write success.
[2026-08-08 20:29:42.727 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:42.727 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:42.827 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:42.827 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:42.927 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:42.927 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:43.027 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:43.027 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:43.093 UTC] [V] 485ChCtl <C1> StartDeviceCommunicationForOutputFluctuationSuppressionControlBroadcast 4 cnt:3605077, monitor_cnt:100, bc_elapsed:27, min:10, max:40
[2026-08-08 20:29:43.094 UTC] [V] OFSCtrl /var/local/solajithome/function/output_fluctuation_suppression/state is exist:0
[2026-08-08 20:29:43.128 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:43.128 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:43.193 UTC] [V] 485ChCtl <C1> StartDeviceCommunicationForOutputFluctuationSuppressionControlBroadcast 4 cnt:3605078, monitor_cnt:101, bc_elapsed:28, min:10, max:40
[2026-08-08 20:29:43.193 UTC] [V] 485DevCtl <C1:02> Dev not PCS IsNeedToChangeOControlState
[2026-08-08 20:29:43.193 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :1
[2026-08-08 20:29:43.194 UTC] [V] 485ChCtl <C1> send request:IMT01
[2026-08-08 20:29:43.195 UTC] [D] 485AcReq <C1:02> PutOStream [1][08000204000200019039]
[2026-08-08 20:29:43.228 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:43.228 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:43.328 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:43.328 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:43.328 UTC] [V] OFSCtrl Control charge discharge proc start.
[2026-08-08 20:29:43.328 UTC] [V] OFSCtrl CHG 20 p_th(t):-1109.900000 = p_th_old_:-1100.000000 + lev_cd_:-0.300000 * (total_pcs_capacity_:99000.000000 * cof_spec_:2.000000 / 60 * (time_threshold_renew:10.000000 * 10)), min:-1100.000000, max:119300.000000
[2026-08-08 20:29:43.329 UTC] [V] OFSCtrl CHG 21 batt_w:344.119526 = old:347.557026 +  kp:0.550000 * e:-6.250000 + ki:0.000000 * sume:9163218.200228 + kd:0.040000 * (e:-6.250000 - e1:-6.250000)
[2026-08-08 20:29:43.329 UTC] [V] OFSCtrl CHG 29 q:3.000000, mod(round):0.000000
[2026-08-08 20:29:43.329 UTC] [D] OFSCtrl battery ctrl val:0.700000
[2026-08-08 20:29:43.330 UTC] [V] 485ChCtl <C3> battery limit on [3.000000,] request.
[2026-08-08 20:29:43.330 UTC] [V] OFSCtrl Control charge discharge proc:01->02->BATT_CHK->03->04->05->06->07->10->11->20->21->22->23->24->25->27->28->29->30->31->32->33->34
[2026-08-08 20:29:43.428 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:43.428 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:43.429 UTC] [V] 485ChCtl <C3> battery send request.1
[2026-08-08 20:29:43.430 UTC] [D] VarInf Limit_Bat rt[2]set val[3] set rate[0.600000] value100[500] value-100[-500]
[2026-08-08 20:29:43.432 UTC] [D] 485AcReq <C3:01> PutOStream [6][0f000001000000090110278e0001020003]
[2026-08-08 20:29:43.526 UTC] [V] 485DevCtl <C1:02> AnalyzeResponseData proc restart cnt:360497 UPRstat:0
[2026-08-08 20:29:43.526 UTC] [V] Res no response condition. set normal condition.
[2026-08-08 20:29:43.526 UTC] [D] 485DevCtl <C1:02> RcvDat status[2] len[7] [02040202067c52]
[2026-08-08 20:29:43.526 UTC] [D] 485DevCtl <C1:02> ResCnd OperationId [1] IsNormal[1] 
[2026-08-08 20:29:43.528 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:43.528 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:43.529 UTC] [V] 485DevCtl <C1:02> [01][431005][268.000000][1][°C]
[2026-08-08 20:29:43.529 UTC] [V] SummDat SetVrmValue dev_id:2 val:26800.000000 sc:3
[2026-08-08 20:29:43.529 UTC] [V] OCMgr SetMeterValue PhId:0102, branchNo:01, valueId:431005, value:268.000000, scaleFactor:1, devId:2
[2026-08-08 20:29:43.530 UTC] [V] 485DevCtl <C1:02> device_type:
[2026-08-08 20:29:43.530 UTC] [V] 485ChCtl <C1> set rt:0
[2026-08-08 20:29:43.587 UTC] [V] 485DevCtl <C3:01> AnalyzeResponseData proc restart cnt:360503 UPRstat:0
[2026-08-08 20:29:43.590 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-08 20:29:43.590 UTC] [D] 485DevCtl <C3:01> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-08 20:29:43.590 UTC] [D] 485DevCtl <C3:01> ResCnd OperationId [6] IsNormal[1] 
[2026-08-08 20:29:43.590 UTC] [V] 485DevCtl <C3:01> device_type:Battery
[2026-08-08 20:29:43.591 UTC] [V] 485ChCtl <C3> set rt:0
[2026-08-08 20:29:43.593 UTC] [V] 485ChCtl <C1> StartDeviceCommunicationForOutputFluctuationSuppressionControlBroadcast 4 cnt:3605082, monitor_cnt:105, bc_elapsed:32, min:10, max:40
[2026-08-08 20:29:43.593 UTC] [V] 485DevCtl <C1:03> Dev not PCS IsNeedToChangeOControlState
[2026-08-08 20:29:43.594 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :1
[2026-08-08 20:29:43.594 UTC] [V] 485ChCtl <C1> send request:omron03
[2026-08-08 20:29:43.595 UTC] [D] 485AcReq <C1:03> PutOStream [1][08000303000000144427]
[2026-08-08 20:29:43.628 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:43.628 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:43.679 UTC] [V] OFSCtrl [/var/local/solajithome/function/output_fluctuation_suppression/batt_data] write success.
[2026-08-08 20:29:43.728 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:43.728 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:43.828 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:43.828 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:43.928 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:43.928 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:43.991 UTC] [V] 485DevCtl <C1:03> AnalyzeResponseData proc restart cnt:360497 UPRstat:0
[2026-08-08 20:29:43.992 UTC] [V] Res no response condition. set normal condition.
[2026-08-08 20:29:43.993 UTC] [D] 485DevCtl <C1:03> RcvDat status[2] len[45] [0303280000fe5e000100630001001f000021bd000025e700002ce90000005f0000025900103643000029802b2c]
[2026-08-08 20:29:43.993 UTC] [D] 485DevCtl <C1:03> ResCnd OperationId [1] IsNormal[1] 
[2026-08-08 20:29:43.995 UTC] [V] 485DevCtl <C1:03> [01][301200][65118.000000][1][V]
[2026-08-08 20:29:43.995 UTC] [V] SummDat SetVrmValue dev_id:3 val:6511800.000000 sc:3
[2026-08-08 20:29:43.995 UTC] [V] OCMgr SetMeterValue PhId:0103, branchNo:01, valueId:301200, value:65118.000000, scaleFactor:1, devId:3
[2026-08-08 20:29:44.000 UTC] [V] 485DevCtl <C1:03> [01][301201][8637.000000][3][A]
[2026-08-08 20:29:44.000 UTC] [V] SummDat SetVrmValue dev_id:3 val:8637.000000 sc:3
[2026-08-08 20:29:44.003 UTC] [V] OCMgr SetMeterValue PhId:0103, branchNo:01, valueId:301201, value:8637.000000, scaleFactor:3, devId:3
[2026-08-08 20:29:44.010 UTC] [V] OFSCtrl Rcv set p_grid:106240.000000
[2026-08-08 20:29:44.010 UTC] [V] 485DevCtl <C1:03> [01][601202][10624.000000][2][kW]
[2026-08-08 20:29:44.010 UTC] [V] SummDat SetVrmValue dev_id:3 val:106240.000000 sc:3
[2026-08-08 20:29:44.011 UTC] [V] OCMgr SetMeterValue PhId:0103, branchNo:01, valueId:601202, value:10624.000000, scaleFactor:2, devId:3
[2026-08-08 20:29:44.011 UTC] [V] 485DevCtl <C1:03> device_type:Grid-Meter
[2026-08-08 20:29:44.012 UTC] [V] 485ChCtl <C1> set rt:0
[2026-08-08 20:29:44.028 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:44.028 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:44.093 UTC] [V] 485ChCtl <C1> StartDeviceCommunicationForOutputFluctuationSuppressionControlBroadcast 4 cnt:3605087, monitor_cnt:110, bc_elapsed:37, min:10, max:40
[2026-08-08 20:29:44.128 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:44.128 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:44.193 UTC] [V] 485ChCtl <C1> StartDeviceCommunicationForOutputFluctuationSuppressionControlBroadcast 4 cnt:3605088, monitor_cnt:111, bc_elapsed:38, min:10, max:40
[2026-08-08 20:29:44.193 UTC] [V] 485DevCtl <C1:05> Dev not PCS IsNeedToChangeOControlState
[2026-08-08 20:29:44.193 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :1
[2026-08-08 20:29:44.194 UTC] [V] 485ChCtl <C1> send request:omron04
[2026-08-08 20:29:44.194 UTC] [D] 485AcReq <C1:05> PutOStream [1][0800050300030014b441]
[2026-08-08 20:29:44.228 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:44.228 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:44.328 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:44.328 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:44.328 UTC] [V] OFSCtrl Control charge discharge proc start.
[2026-08-08 20:29:44.328 UTC] [V] OFSCtrl CHG 20 p_th(t):-1109.900000 = p_th_old_:-1100.000000 + lev_cd_:-0.300000 * (total_pcs_capacity_:99000.000000 * cof_spec_:2.000000 / 60 * (time_threshold_renew:10.000000 * 10)), min:-1100.000000, max:119300.000000
[2026-08-08 20:29:44.329 UTC] [V] OFSCtrl CHG 21 batt_w:340.682026 = old:344.119526 +  kp:0.550000 * e:-6.250000 + ki:0.000000 * sume:9163211.950228 + kd:0.040000 * (e:-6.250000 - e1:-6.250000)
[2026-08-08 20:29:44.329 UTC] [V] OFSCtrl CHG 29 q:3.000000, mod(round):0.000000
[2026-08-08 20:29:44.330 UTC] [D] OFSCtrl battery ctrl val:0.700000
[2026-08-08 20:29:44.330 UTC] [V] 485ChCtl <C3> battery limit on [3.000000,] request.
[2026-08-08 20:29:44.330 UTC] [V] OFSCtrl Control charge discharge proc:01->02->BATT_CHK->03->04->05->06->07->10->11->20->21->22->23->24->25->27->28->29->30->31->32->33->34
[2026-08-08 20:29:44.427 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:44.427 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:44.429 UTC] [V] 485ChCtl <C3> battery send request.1
[2026-08-08 20:29:44.430 UTC] [D] VarInf Limit_Bat rt[2]set val[3] set rate[0.600000] value100[500] value-100[-500]
[2026-08-08 20:29:44.431 UTC] [D] 485AcReq <C3:01> PutOStream [6][0f000001000000090110278e0001020003]
[2026-08-08 20:29:44.528 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:44.528 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:44.588 UTC] [V] 485DevCtl <C3:01> AnalyzeResponseData proc restart cnt:360504 UPRstat:0
[2026-08-08 20:29:44.589 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-08 20:29:44.590 UTC] [D] 485DevCtl <C3:01> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-08 20:29:44.590 UTC] [D] 485DevCtl <C3:01> ResCnd OperationId [6] IsNormal[1] 
[2026-08-08 20:29:44.590 UTC] [V] 485DevCtl <C3:01> device_type:Battery
[2026-08-08 20:29:44.590 UTC] [V] 485ChCtl <C3> set rt:0
[2026-08-08 20:29:44.592 UTC] [V] 485DevCtl <C1:05> AnalyzeResponseData proc restart cnt:360497 UPRstat:0
[2026-08-08 20:29:44.592 UTC] [V] Res no response condition. set normal condition.
[2026-08-08 20:29:44.593 UTC] [D] 485DevCtl <C1:05> RcvDat status[2] len[45] [050328000020aa000015bf000016d0ffffffda00000258ffffdf16ffffffacffffb106ffffff360013853908a2]
[2026-08-08 20:29:44.593 UTC] [D] 485DevCtl <C1:05> ResCnd OperationId [1] IsNormal[1] 
[2026-08-08 20:29:44.595 UTC] [V] OFSCtrl Rcv set p_pv:-840.000000
[2026-08-08 20:29:44.595 UTC] [V] 485DevCtl <C1:05> [01][601259][-84.000000][2][kW]
[2026-08-08 20:29:44.595 UTC] [V] SummDat SetVrmValue dev_id:5 val:-840.000000 sc:3
[2026-08-08 20:29:44.598 UTC] [V] OCMgr SetMeterValue PhId:0105, branchNo:01, valueId:601259, value:-84.000000, scaleFactor:2, devId:5
[2026-08-08 20:29:44.599 UTC] [V] 485DevCtl <C1:05> [01][603259][1279289.000000][1][kWh]
[2026-08-08 20:29:44.608 UTC] [V] SummDat SetVrmValue dev_id:5 val:1279289.000000 sc:1
[2026-08-08 20:29:44.613 UTC] [V] OCMgr SetMeterValue PhId:0105, branchNo:01, valueId:603259, value:1279289.000000, scaleFactor:1, devId:5
[2026-08-08 20:29:44.613 UTC] [V] 485DevCtl <C1:05> device_type:PV-Meter
[2026-08-08 20:29:44.620 UTC] [V] 485ChCtl <C1> set rt:0
[2026-08-08 20:29:44.628 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:44.628 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:44.679 UTC] [V] OFSCtrl [/var/local/solajithome/function/output_fluctuation_suppression/batt_data] write success.
[2026-08-08 20:29:44.693 UTC] [V] 485ChCtl <C1> monitor no transmission period.
[2026-08-08 20:29:44.729 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:44.729 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:44.793 UTC] [V] 485ChCtl <C1> monitor no transmission period.
[2026-08-08 20:29:44.828 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:44.828 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:44.893 UTC] [V] 485ChCtl <C1> monitor no transmission period.
[2026-08-08 20:29:44.928 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:44.928 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:44.993 UTC] [V] 485ChCtl <C1> monitor no transmission period.
[2026-08-08 20:29:45.028 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:45.028 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:45.093 UTC] [V] 485ChCtl <C1> monitor no transmission period.
[2026-08-08 20:29:45.127 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:45.128 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:45.193 UTC] [V] 485ChCtl <C1> monitor no transmission period.
[2026-08-08 20:29:45.227 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:45.228 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:45.292 UTC] [V] 485ChCtl <C1> monitor no transmission period.
[2026-08-08 20:29:45.328 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:45.328 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:45.328 UTC] [V] OFSCtrl Control charge discharge proc start.
[2026-08-08 20:29:45.329 UTC] [V] OFSCtrl CHG 20 p_th(t):-1109.900000 = p_th_old_:-1100.000000 + lev_cd_:-0.300000 * (total_pcs_capacity_:99000.000000 * cof_spec_:2.000000 / 60 * (time_threshold_renew:10.000000 * 10)), min:-1100.000000, max:119300.000000
[2026-08-08 20:29:45.329 UTC] [V] OFSCtrl CHG 21 batt_w:337.244526 = old:340.682026 +  kp:0.550000 * e:-6.250000 + ki:0.000000 * sume:9163205.700228 + kd:0.040000 * (e:-6.250000 - e1:-6.250000)
[2026-08-08 20:29:45.330 UTC] [V] OFSCtrl CHG 29 q:3.000000, mod(round):0.000000
[2026-08-08 20:29:45.330 UTC] [D] OFSCtrl battery ctrl val:0.700000
[2026-08-08 20:29:45.330 UTC] [V] 485ChCtl <C3> battery limit on [3.000000,] request.
[2026-08-08 20:29:45.330 UTC] [V] OFSCtrl Control charge discharge proc:01->02->BATT_CHK->03->04->05->06->07->10->11->20->21->22->23->24->25->27->28->29->30->31->32->33->34
[2026-08-08 20:29:45.376 UTC] [V] OC485DevMgr TargetPowerPolling 
[2026-08-08 20:29:45.376 UTC] [V] OC485DevMgr TargetPowerPolling Target power no ud current[20260808200000]now[20260808202945]next[20260808203000]
[2026-08-08 20:29:45.376 UTC] [V] OCMgr UpdateExtCurrentTarget call
[2026-08-08 20:29:45.376 UTC] [V] OCMgr UpdateExtSchedule call
[2026-08-08 20:29:45.377 UTC] [V] OCMgr UpdateExtSchedule file none. ext rate:-1, time:20200101000000
[2026-08-08 20:29:45.377 UTC] [V] OCMgr IsPvocdScheduleError 0
[2026-08-08 20:29:45.377 UTC] [V] OCMgr UpdateExtCurrentTarget check schedule:0, ext rate:-1
[2026-08-08 20:29:45.377 UTC] [V] OCMgr CalcOutputControlPower pow:99.000000, rate:100, cap:99.000000
[2026-08-08 20:29:45.378 UTC] [V] OCMgr IsPvocdScheduleError 0
[2026-08-08 20:29:45.378 UTC] [D] OCMgr UpdateExtCurrentTarget external none, in_pow:99.000000, 99.000000
[2026-08-08 20:29:45.380 UTC] [V] OCMgr CalcOutputControlRate rate:100, pow:99.000000, cap:99.000000, rate_out:99.000000
[2026-08-08 20:29:45.381 UTC] [V] OCMgr WriteExtSchedule dat:100,20260809053000
[2026-08-08 20:29:45.387 UTC] [V] FlUtil write csv file[/media/sdcard/solajithome/Log/modbus/ExecSchedulePath/ExecEmsSchedule.csv] result:1
[2026-08-08 20:29:45.393 UTC] [V] 485DevCtl <C1:01> device_type:Irr-Meter
[2026-08-08 20:29:45.393 UTC] [V] 485DevCtl <C1:01> device_type:Irr-Meter
[2026-08-08 20:29:45.393 UTC] [V] 485ChCtl <C1> fixed cycle Irr-Meter
[2026-08-08 20:29:45.393 UTC] [V] 485DevCtl <C1:01> Dev not PCS IsNeedToChangeOControlState
[2026-08-08 20:29:45.393 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :1
[2026-08-08 20:29:45.394 UTC] [V] 485ChCtl <C1> send request:Irr01
[2026-08-08 20:29:45.394 UTC] [D] 485AcReq <C1:01> PutOStream [1][080001040000000271cb]
[2026-08-08 20:29:45.397 UTC] [V] OCMgr now time:20260808200000, power_value:99.000000, rt:0
[2026-08-08 20:29:45.403 UTC] [V] OCMgr next time:20260808203000, power_value:99.000000, rt:0
[2026-08-08 20:29:45.408 UTC] [V] OCMgr GetCurrentTargetPower current target:99.000000
[2026-08-08 20:29:45.408 UTC] [V] OCMgr CalcOutputControlRate rate:100, pow:99.000000, cap:99.000000, rate_out:99.000000
[2026-08-08 20:29:45.409 UTC] [V] OCMgr IsPvocdCommunication 1
[2026-08-08 20:29:45.409 UTC] [V] OCMgr IsPvocdScheduleError 0
[2026-08-08 20:29:45.409 UTC] [V] OCMgr UpdateActiveMode mode:OFS conditions:output rate 100.
[2026-08-08 20:29:45.409 UTC] [V] LgMgr change mode OFS -> OFS
[2026-08-08 20:29:45.427 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:45.427 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:45.429 UTC] [V] 485ChCtl <C3> battery send request.1
[2026-08-08 20:29:45.430 UTC] [D] VarInf Limit_Bat rt[2]set val[3] set rate[0.600000] value100[500] value-100[-500]
[2026-08-08 20:29:45.432 UTC] [D] 485AcReq <C3:01> PutOStream [6][0f000001000000090110278e0001020003]
[2026-08-08 20:29:45.528 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:45.528 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:45.541 UTC] [I] Wdog command:/usr/bin/touch "/mnt/system/check/pvsl"
[2026-08-08 20:29:45.590 UTC] [V] 485DevCtl <C3:01> AnalyzeResponseData proc restart cnt:360505 UPRstat:0
[2026-08-08 20:29:45.591 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-08 20:29:45.592 UTC] [D] 485DevCtl <C3:01> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-08 20:29:45.592 UTC] [D] 485DevCtl <C3:01> ResCnd OperationId [6] IsNormal[1] 
[2026-08-08 20:29:45.592 UTC] [V] 485DevCtl <C3:01> device_type:Battery
[2026-08-08 20:29:45.593 UTC] [V] 485ChCtl <C3> set rt:0
[2026-08-08 20:29:45.628 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:45.628 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:45.679 UTC] [V] OFSCtrl [/var/local/solajithome/function/output_fluctuation_suppression/batt_data] write success.
[2026-08-08 20:29:45.728 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:45.728 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:45.731 UTC] [V] 485ChCtl <C3> StartDeviceCommunicationForOutputFluctuationSuppressionControlBroadcast 4 cnt:3605103, monitor_cnt:50, bc_elapsed:3605103, min:10, max:40
[2026-08-08 20:29:45.731 UTC] [V] OFSCtrl /var/local/solajithome/function/output_fluctuation_suppression/state is exist:0
[2026-08-08 20:29:45.731 UTC] [V] 485DevCtl <C3:01> Dev not PCS IsNeedToChangeOControlState
[2026-08-08 20:29:45.732 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :12
[2026-08-08 20:29:45.732 UTC] [V] 485ChCtl <C3> send request:Sungrow11
[2026-08-08 20:29:45.733 UTC] [V] 485DevCtl <C1:01> AnalyzeResponseData proc restart cnt:360506 UPRstat:0
[2026-08-08 20:29:45.733 UTC] [V] Res no response condition. set normal condition.
[2026-08-08 20:29:45.734 UTC] [D] 485DevCtl <C1:01> RcvDat status[2] len[9] [010404000002013b24]
[2026-08-08 20:29:45.734 UTC] [D] 485DevCtl <C1:01> ResCnd OperationId [1] IsNormal[1] 
[2026-08-08 20:29:45.734 UTC] [V] OFSCtrl Rcv set flux_of_solar:0.000000
[2026-08-08 20:29:45.734 UTC] [V] 485DevCtl <C1:01> [01][401006][0.000000][1][W/m2]
[2026-08-08 20:29:45.735 UTC] [V] SummDat SetVrmValue dev_id:1 val:0.000000 sc:3
[2026-08-08 20:29:45.736 UTC] [V] OCMgr SetMeterValue PhId:0101, branchNo:01, valueId:401006, value:0.000000, scaleFactor:1, devId:1
[2026-08-08 20:29:45.736 UTC] [V] 485DevCtl <C1:01> [01][421005][263.000000][1][℃]
[2026-08-08 20:29:45.737 UTC] [V] SummDat SetVrmValue dev_id:1 val:26300.000000 sc:3
[2026-08-08 20:29:45.737 UTC] [V] OCMgr SetMeterValue PhId:0101, branchNo:01, valueId:421005, value:263.000000, scaleFactor:1, devId:1
[2026-08-08 20:29:45.738 UTC] [D] 485AcReq <C3:01> PutOStream [12][0c00000100000006010427580001]
[2026-08-08 20:29:45.737 UTC] [V] 485DevCtl <C1:01> device_type:Irr-Meter
[2026-08-08 20:29:45.748 UTC] [V] OFSCtrl Irr-Meter received.
[2026-08-08 20:29:45.756 UTC] [V] 485ChCtl <C1> set rt:0
[2026-08-08 20:29:45.757 UTC] [V] 485DevCtl <C1:01> device_type:Irr-Meter
[2026-08-08 20:29:45.793 UTC] [V] 485DevCtl <C1:04> device_type:CO-Meter
[2026-08-08 20:29:45.793 UTC] [V] 485DevCtl <C1:04> device_type:CO-Meter
[2026-08-08 20:29:45.793 UTC] [V] 485ChCtl <C1> fixed cycle CO-Meter
[2026-08-08 20:29:45.793 UTC] [V] 485DevCtl <C1:04> Dev not PCS IsNeedToChangeOControlState
[2026-08-08 20:29:45.793 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :1
[2026-08-08 20:29:45.794 UTC] [V] 485ChCtl <C1> send request:omron05
[2026-08-08 20:29:45.796 UTC] [D] 485AcReq <C1:04> PutOStream [1][0800040300030014b590]
[2026-08-08 20:29:45.828 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:45.828 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:45.857 UTC] [V] 485DevCtl <C3:01> AnalyzeResponseData proc restart cnt:360505 UPRstat:0
[2026-08-08 20:29:45.859 UTC] [D] 485DevCtl <C3:01> RcvDat status[0] len[11] [0001000000050104020010]
[2026-08-08 20:29:45.859 UTC] [D] 485DevCtl <C3:01> ResCnd OperationId [12] IsNormal[1]  ConditionType [lggrdev:Normal] Action[-1]
[2026-08-08 20:29:45.860 UTC] [V] 485DevCtl <C3:01> [02][753040][1.000000][0][]
[2026-08-08 20:29:45.860 UTC] [V] SummDat SetVrmValue dev_id:9 val:1.000000 sc:0
[2026-08-08 20:29:45.860 UTC] [V] OCMgr SetMeterValue PhId:0301, branchNo:02, valueId:753040, value:1.000000, scaleFactor:0, devId:9
[2026-08-08 20:29:45.861 UTC] [V] 485DevCtl <C3:01> device_type:Battery
[2026-08-08 20:29:45.878 UTC] [V] 485ChCtl <C3> set rt:0
[2026-08-08 20:29:45.881 UTC] [D] 485ChCtl <C3> monitoring dev All Send
[2026-08-08 20:29:45.928 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:45.928 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:46.009 UTC] [V] 485ChCtl <C2> StartDeviceCommunicationForOutputFluctuationSuppressionControlBroadcast 4 cnt:3605106, monitor_cnt:50, bc_elapsed:3605106, min:10, max:40
[2026-08-08 20:29:46.009 UTC] [V] OFSCtrl /var/local/solajithome/function/output_fluctuation_suppression/state is exist:0
[2026-08-08 20:29:46.010 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :9
[2026-08-08 20:29:46.010 UTC] [V] 485ChCtl <C2> send request:Sungrow08
[2026-08-08 20:29:46.011 UTC] [D] 485AcReq <C2:01> PutOStream [9][0800010413fa001794b1]
[2026-08-08 20:29:46.028 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:46.028 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:46.128 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:46.128 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:46.200 UTC] [V] 485DevCtl <C1:04> AnalyzeResponseData proc restart cnt:360505 UPRstat:0
[2026-08-08 20:29:46.200 UTC] [V] Res no response condition. set normal condition.
[2026-08-08 20:29:46.202 UTC] [D] 485DevCtl <C1:04> RcvDat status[2] len[45] [040328000022480000180b00001813ffffffe500000257ffffe869ffffffc4ffffaf03ffffff3100121a81a2c9]
[2026-08-08 20:29:46.202 UTC] [D] 485DevCtl <C1:04> ResCnd OperationId [1] IsNormal[1] 
[2026-08-08 20:29:46.202 UTC] [V] OFSCtrl Rcv set p_co:-600.000000, p_co_old:-610.000000
[2026-08-08 20:29:46.202 UTC] [V] 485DevCtl <C1:04> [01][601260][-60.000000][2][kW]
[2026-08-08 20:29:46.203 UTC] [V] SummDat SetVrmValue dev_id:4 val:-600.000000 sc:3
[2026-08-08 20:29:46.203 UTC] [V] OCMgr SetMeterValue PhId:0104, branchNo:01, valueId:601260, value:-60.000000, scaleFactor:2, devId:4
[2026-08-08 20:29:46.203 UTC] [V] 485DevCtl <C1:04> [01][603260][1186433.000000][1][kWh]
[2026-08-08 20:29:46.203 UTC] [V] SummDat SetVrmValue dev_id:4 val:1186433.000000 sc:1
[2026-08-08 20:29:46.204 UTC] [V] OCMgr SetMeterValue PhId:0104, branchNo:01, valueId:603260, value:1186433.000000, scaleFactor:1, devId:4
[2026-08-08 20:29:46.204 UTC] [V] 485DevCtl <C1:04> device_type:CO-Meter
[2026-08-08 20:29:46.204 UTC] [V] OFSCtrl km50 received.
[2026-08-08 20:29:46.204 UTC] [V] OFSCtrl omron05_local_date :2026/08/09 ? 2026/08/09
[2026-08-08 20:29:46.204 UTC] [V] OFSCtrl omron05_local_time :2026/08/09 05 ? 2026/08/09 05
[2026-08-08 20:29:46.204 UTC] [V] OFSCtrl out of control time.
[2026-08-08 20:29:46.205 UTC] [V] OFSCtrl Control pv-pcs proc start.
[2026-08-08 20:29:46.205 UTC] [V] OFSCtrl NOD_month:-1664.000000 = (NOD_month:306 - ((nod_max_/30):23.333333 * (cnt-1):25) * (30/cnt):6.000000 
[2026-08-08 20:29:46.205 UTC] [V] OFSCtrl PCS ratio_month:232.646617 = -k_inhibition_ratio_month:-0.097744 * NOD_month:-1664.000000 + inhibition_ratio_max:70
[2026-08-08 20:29:46.228 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:46.228 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:46.244 UTC] [V] OFSCtrl PCS 05 inhibition_ratio:70.000000 = max(ratio_min:5, min(ratio:70, ratio_hour:70.000000, ratio_day:70.000000, ratio_month:232.646617))
[2026-08-08 20:29:46.244 UTC] [D] OFSCtrl pv-pcs ctrl val:0.000000 old:0.000000
[2026-08-08 20:29:46.244 UTC] [V] OCHisDB set rate:0 t_rate:0 cnt:56
[2026-08-08 20:29:46.244 UTC] [V] 485ChCtl <C2> pv-pcs limit on [0.000000] request.
[2026-08-08 20:29:46.245 UTC] [V] OFSCtrl Control pv-pcs proc:BATT_CHK->01->02->03->04->05->06->07->09->09->10->11->12
[2026-08-08 20:29:46.245 UTC] [V] 485ChCtl <C1> set rt:0
[2026-08-08 20:29:46.265 UTC] [V] 485DevCtl <C1:04> device_type:CO-Meter
[2026-08-08 20:29:46.293 UTC] [V] 485ChCtl <C1> monitor no transmission period.
[2026-08-08 20:29:46.328 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:46.328 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:46.328 UTC] [V] OFSCtrl Control charge discharge proc start.
[2026-08-08 20:29:46.328 UTC] [V] OFSCtrl CHG 20 p_th(t):-1109.900000 = p_th_old_:-1100.000000 + lev_cd_:-0.300000 * (total_pcs_capacity_:99000.000000 * cof_spec_:2.000000 / 60 * (time_threshold_renew:10.000000 * 10)), min:-1100.000000, max:119300.000000
[2026-08-08 20:29:46.329 UTC] [V] OFSCtrl CHG 21 batt_w:333.807026 = old:337.244526 +  kp:0.550000 * e:-6.250000 + ki:0.000000 * sume:9163199.450228 + kd:0.040000 * (e:-6.250000 - e1:-6.250000)
[2026-08-08 20:29:46.330 UTC] [V] OFSCtrl CHG 29 q:3.000000, mod(round):0.000000
[2026-08-08 20:29:46.330 UTC] [D] OFSCtrl battery ctrl val:0.700000
[2026-08-08 20:29:46.331 UTC] [V] 485ChCtl <C3> battery limit on [3.000000,] request.
[2026-08-08 20:29:46.331 UTC] [V] OFSCtrl Control charge discharge proc:01->02->BATT_CHK->03->04->05->06->07->10->11->20->21->22->23->24->25->27->28->29->30->31->32->33->34
[2026-08-08 20:29:46.391 UTC] [V] Res no response condition. set normal condition.
[2026-08-08 20:29:46.392 UTC] [V] 485ChCtl <C1> monitor no transmission period.
[2026-08-08 20:29:46.392 UTC] [D] 485DevCtl <C2:01> RcvDat status[2] len[51] [01042e000000000000000000000000ffffffffffffffff03e8ffffffff41060000ffffffffffffffffffffffffffffffff406b]
[2026-08-08 20:29:46.393 UTC] [D] 485DevCtl <C2:01> ResCnd OperationId [9] IsNormal[1] 
[2026-08-08 20:29:46.393 UTC] [V] 485DevCtl <C2:01> [04][101100][0.000000][1][V]
[2026-08-08 20:29:46.393 UTC] [V] SummDat SetVrmValue dev_id:7 val:0.000000 sc:3
[2026-08-08 20:29:46.394 UTC] [V] OCMgr SetMeterValue PhId:0201, branchNo:04, valueId:101100, value:0.000000, scaleFactor:1, devId:7
[2026-08-08 20:29:46.394 UTC] [V] 485DevCtl <C2:01> [04][101101][0.000000][1][A]
[2026-08-08 20:29:46.394 UTC] [V] SummDat SetVrmValue dev_id:7 val:0.000000 sc:3
[2026-08-08 20:29:46.395 UTC] [V] OCMgr SetMeterValue PhId:0201, branchNo:04, valueId:101101, value:0.000000, scaleFactor:1, devId:7
[2026-08-08 20:29:46.395 UTC] [V] 485DevCtl <C2:01> [05][101100][0.000000][1][V]
[2026-08-08 20:29:46.406 UTC] [V] SummDat SetVrmValue dev_id:7 val:0.000000 sc:3
[2026-08-08 20:29:46.413 UTC] [V] OCMgr SetMeterValue PhId:0201, branchNo:05, valueId:101100, value:0.000000, scaleFactor:1, devId:7
[2026-08-08 20:29:46.413 UTC] [V] 485DevCtl <C2:01> [05][101101][0.000000][1][A]
[2026-08-08 20:29:46.414 UTC] [V] SummDat SetVrmValue dev_id:7 val:0.000000 sc:3
[2026-08-08 20:29:46.414 UTC] [V] OCMgr SetMeterValue PhId:0201, branchNo:05, valueId:101101, value:0.000000, scaleFactor:1, devId:7
[2026-08-08 20:29:46.426 UTC] [V] 485DevCtl <C2:01> [06][101100][0.000000][1][V]
[2026-08-08 20:29:46.426 UTC] [V] SummDat SetVrmValue dev_id:7 val:0.000000 sc:3
[2026-08-08 20:29:46.426 UTC] [V] OCMgr SetMeterValue PhId:0201, branchNo:06, valueId:101100, value:0.000000, scaleFactor:1, devId:7
[2026-08-08 20:29:46.427 UTC] [V] 485DevCtl <C2:01> [06][101101][0.000000][1][A]
[2026-08-08 20:29:46.427 UTC] [V] SummDat SetVrmValue dev_id:7 val:0.000000 sc:3
[2026-08-08 20:29:46.428 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:46.428 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:46.429 UTC] [V] 485ChCtl <C3> battery send request.1
[2026-08-08 20:29:46.430 UTC] [D] VarInf Limit_Bat rt[2]set val[3] set rate[0.600000] value100[500] value-100[-500]
[2026-08-08 20:29:46.431 UTC] [D] 485AcReq <C3:01> PutOStream [6][0f000001000000090110278e0001020003]
[2026-08-08 20:29:46.453 UTC] [V] OCMgr SetMeterValue PhId:0201, branchNo:06, valueId:101101, value:0.000000, scaleFactor:1, devId:7
[2026-08-08 20:29:46.454 UTC] [V] 485DevCtl <C2:01> device_type:PV-PCS
[2026-08-08 20:29:46.473 UTC] [V] 485ChCtl <C2> set rt:0
[2026-08-08 20:29:46.493 UTC] [V] 485ChCtl <C1> StartDeviceCommunicationForOutputFluctuationSuppressionControlBroadcast 4 cnt:3605111, monitor_cnt:134, bc_elapsed:11, min:10, max:40
[2026-08-08 20:29:46.493 UTC] [V] 485DevCtl <C1:06> Dev not PCS IsNeedToChangeOControlState
[2026-08-08 20:29:46.493 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :1
[2026-08-08 20:29:46.494 UTC] [V] 485ChCtl <C1> send request:omron06
[2026-08-08 20:29:46.496 UTC] [D] 485AcReq <C1:06> PutOStream [1][08000603000000144472]
[2026-08-08 20:29:46.510 UTC] [V] 485ChCtl <C2> pv-pcs send request.
[2026-08-08 20:29:46.510 UTC] [D] VarInf update ofs_rate:0.000000
[2026-08-08 20:29:46.510 UTC] [V] VarInf LimitSet rt[2] val[170] key[ValueOn]
[2026-08-08 20:29:46.510 UTC] [D] VarInf output_mode:8
[2026-08-08 20:29:46.510 UTC] [D] VarInf update ofs_rate:0.000000
[2026-08-08 20:29:46.510 UTC] [D] VarInf Limit setRate[0.000000] rate[0.000000] value100[1000.000000] value0[0.000000]
[2026-08-08 20:29:46.511 UTC] [V] 485DevCtl <C2:01> ChangeOutputRateToDevice rate:0.000000 set_rate1
[2026-08-08 20:29:46.511 UTC] [D] VarInf Limit rt[2] int_set_rate[1] server_rate[0.000000] rated_output[100.000000] solar_battery_power[100.000000]
[2026-08-08 20:29:46.512 UTC] [D] 485AcReq <C2:01> PutOStreamForBc [3][0d000010138e00020400aa0001466f]
[2026-08-08 20:29:46.527 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:46.528 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:46.587 UTC] [V] 485DevCtl <C3:01> AnalyzeResponseData proc restart cnt:360506 UPRstat:0
[2026-08-08 20:29:46.589 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-08 20:29:46.590 UTC] [D] 485DevCtl <C3:01> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-08 20:29:46.590 UTC] [D] 485DevCtl <C3:01> ResCnd OperationId [6] IsNormal[1] 
[2026-08-08 20:29:46.590 UTC] [V] 485DevCtl <C3:01> device_type:Battery
[2026-08-08 20:29:46.590 UTC] [V] 485ChCtl <C3> set rt:0
[2026-08-08 20:29:46.627 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:46.628 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:46.679 UTC] [V] OFSCtrl [/var/local/solajithome/function/output_fluctuation_suppression/batt_data] write success.
[2026-08-08 20:29:46.728 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:46.728 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:46.806 UTC] [V] 485ChCtl <C2> set rt:0
[2026-08-08 20:29:46.809 UTC] [V] 485ChCtl <C2> StartDeviceCommunicationForOutputFluctuationSuppressionControlBroadcast 4 cnt:3605114, monitor_cnt:58, bc_elapsed:3605114, min:10, max:40
[2026-08-08 20:29:46.810 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :10
[2026-08-08 20:29:46.810 UTC] [V] 485ChCtl <C2> send request:Sungrow08
[2026-08-08 20:29:46.811 UTC] [D] 485AcReq <C2:02> PutOStream [10][0800020413d80002f547]
[2026-08-08 20:29:46.828 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:46.828 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:46.892 UTC] [V] 485DevCtl <C1:06> AnalyzeResponseData proc restart cnt:360499 UPRstat:0
[2026-08-08 20:29:46.892 UTC] [V] Res no response condition. set normal condition.
[2026-08-08 20:29:46.894 UTC] [D] 485DevCtl <C1:06> RcvDat status[2] len[45] [060328000008060000081600000813000009080000097d000008fd000000640000025800000b210000001c3ed2]
[2026-08-08 20:29:46.894 UTC] [D] 485DevCtl <C1:06> ResCnd OperationId [1] IsNormal[1] 
[2026-08-08 20:29:46.894 UTC] [V] OFSCtrl Rcv set p_batt:280.000000
[2026-08-08 20:29:46.894 UTC] [V] 485DevCtl <C1:06> [01][601237][28.000000][2][kW]
[2026-08-08 20:29:46.895 UTC] [V] SummDat SetVrmValue dev_id:6 val:280.000000 sc:3
[2026-08-08 20:29:46.896 UTC] [V] OCMgr SetMeterValue PhId:0106, branchNo:01, valueId:601237, value:28.000000, scaleFactor:2, devId:6
[2026-08-08 20:29:46.897 UTC] [V] 485DevCtl <C1:06> device_type:Batt-Meter
[2026-08-08 20:29:46.897 UTC] [V] 485ChCtl <C1> set rt:0
[2026-08-08 20:29:46.909 UTC] [D] 485ChCtl <C1> monitoring dev All Send
[2026-08-08 20:29:46.928 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:46.928 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:47.028 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:47.028 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:47.128 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:47.128 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:47.138 UTC] [V] Res no response condition. set normal condition.
[2026-08-08 20:29:47.139 UTC] [D] 485DevCtl <C2:02> RcvDat status[2] len[9] [02040400100000c941]
[2026-08-08 20:29:47.139 UTC] [D] 485DevCtl <C2:02> ResCnd OperationId [10] IsNormal[1] 
[2026-08-08 20:29:47.140 UTC] [V] 485DevCtl <C2:02> device_type:PV-PCS
[2026-08-08 20:29:47.142 UTC] [V] 485ChCtl <C2> set rt:0
[2026-08-08 20:29:47.142 UTC] [D] 485ChCtl <C2> monitoring dev All Send
[2026-08-08 20:29:47.228 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:47.228 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:47.328 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:47.328 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:47.328 UTC] [V] OFSCtrl Control charge discharge proc start.
[2026-08-08 20:29:47.329 UTC] [V] OFSCtrl CHG 20 p_th(t):-1109.900000 = p_th_old_:-1100.000000 + lev_cd_:-0.300000 * (total_pcs_capacity_:99000.000000 * cof_spec_:2.000000 / 60 * (time_threshold_renew:10.000000 * 10)), min:-1100.000000, max:119300.000000
[2026-08-08 20:29:47.329 UTC] [V] OFSCtrl CHG 21 batt_w:330.369526 = old:333.807026 +  kp:0.550000 * e:-6.250000 + ki:0.000000 * sume:9163193.200228 + kd:0.040000 * (e:-6.250000 - e1:-6.250000)
[2026-08-08 20:29:47.329 UTC] [V] OFSCtrl CHG 29 q:3.000000, mod(round):0.000000
[2026-08-08 20:29:47.329 UTC] [D] OFSCtrl battery ctrl val:0.700000
[2026-08-08 20:29:47.330 UTC] [V] 485ChCtl <C3> battery limit on [3.000000,] request.
[2026-08-08 20:29:47.330 UTC] [V] 485ChCtl <C3> battery send request.1
[2026-08-08 20:29:47.330 UTC] [D] VarInf Limit_Bat rt[2]set val[3] set rate[0.600000] value100[500] value-100[-500]
[2026-08-08 20:29:47.332 UTC] [D] 485AcReq <C3:01> PutOStream [6][0f000001000000090110278e0001020003]
[2026-08-08 20:29:47.335 UTC] [V] OFSCtrl Control charge discharge proc:01->02->BATT_CHK->03->04->05->06->07->10->11->20->21->22->23->24->25->27->28->29->30->31->32->33->34
[2026-08-08 20:29:47.428 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:47.428 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:47.477 UTC] [V] 485DevCtl <C3:01> AnalyzeResponseData proc restart cnt:360506 UPRstat:0
[2026-08-08 20:29:47.479 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-08 20:29:47.481 UTC] [D] 485DevCtl <C3:01> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-08 20:29:47.481 UTC] [D] 485DevCtl <C3:01> ResCnd OperationId [6] IsNormal[1] 
[2026-08-08 20:29:47.481 UTC] [V] 485DevCtl <C3:01> device_type:Battery
[2026-08-08 20:29:47.484 UTC] [V] 485ChCtl <C3> set rt:0
[2026-08-08 20:29:47.528 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:47.528 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:47.628 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:47.628 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:47.679 UTC] [V] OFSCtrl [/var/local/solajithome/function/output_fluctuation_suppression/batt_data] write success.
[2026-08-08 20:29:47.728 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:47.728 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:47.828 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:47.828 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:47.928 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:47.928 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:48.027 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:48.028 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:48.127 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:48.128 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:48.227 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:48.228 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:48.327 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:48.327 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:48.328 UTC] [V] OFSCtrl Control charge discharge proc start.
[2026-08-08 20:29:48.328 UTC] [V] OFSCtrl CHG 20 p_th(t):-1109.900000 = p_th_old_:-1100.000000 + lev_cd_:-0.300000 * (total_pcs_capacity_:99000.000000 * cof_spec_:2.000000 / 60 * (time_threshold_renew:10.000000 * 10)), min:-1100.000000, max:119300.000000
[2026-08-08 20:29:48.328 UTC] [V] OFSCtrl CHG 21 batt_w:326.932026 = old:330.369526 +  kp:0.550000 * e:-6.250000 + ki:0.000000 * sume:9163186.950228 + kd:0.040000 * (e:-6.250000 - e1:-6.250000)
[2026-08-08 20:29:48.329 UTC] [V] OFSCtrl CHG 29 q:3.000000, mod(round):0.000000
[2026-08-08 20:29:48.329 UTC] [D] OFSCtrl battery ctrl val:0.700000
[2026-08-08 20:29:48.329 UTC] [V] 485ChCtl <C3> battery limit on [3.000000,] request.
[2026-08-08 20:29:48.329 UTC] [V] OFSCtrl Control charge discharge proc:01->02->BATT_CHK->03->04->05->06->07->10->11->20->21->22->23->24->25->27->28->29->30->31->32->33->34
[2026-08-08 20:29:48.330 UTC] [V] 485ChCtl <C3> battery send request.1
[2026-08-08 20:29:48.330 UTC] [D] VarInf Limit_Bat rt[2]set val[3] set rate[0.600000] value100[500] value-100[-500]
[2026-08-08 20:29:48.331 UTC] [D] 485AcReq <C3:01> PutOStream [6][0f000001000000090110278e0001020003]
[2026-08-08 20:29:48.428 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:48.428 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:48.497 UTC] [V] 485DevCtl <C3:01> AnalyzeResponseData proc restart cnt:360507 UPRstat:0
[2026-08-08 20:29:48.499 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-08 20:29:48.500 UTC] [D] 485DevCtl <C3:01> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-08 20:29:48.501 UTC] [D] 485DevCtl <C3:01> ResCnd OperationId [6] IsNormal[1] 
[2026-08-08 20:29:48.501 UTC] [V] 485DevCtl <C3:01> device_type:Battery
[2026-08-08 20:29:48.501 UTC] [V] 485ChCtl <C3> set rt:0
[2026-08-08 20:29:48.528 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:48.528 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:48.628 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:48.628 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:48.679 UTC] [V] OFSCtrl [/var/local/solajithome/function/output_fluctuation_suppression/batt_data] write success.
[2026-08-08 20:29:48.728 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:48.728 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:48.828 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:48.828 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:48.928 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:48.928 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:49.028 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:49.028 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:49.128 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:49.128 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:49.228 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:49.228 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:49.328 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:49.328 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:49.328 UTC] [V] OFSCtrl Control charge discharge proc start.
[2026-08-08 20:29:49.329 UTC] [V] OFSCtrl CHG 20 p_th(t):-1109.900000 = p_th_old_:-1100.000000 + lev_cd_:-0.300000 * (total_pcs_capacity_:99000.000000 * cof_spec_:2.000000 / 60 * (time_threshold_renew:10.000000 * 10)), min:-1100.000000, max:119300.000000
[2026-08-08 20:29:49.329 UTC] [V] OFSCtrl CHG 21 batt_w:323.494526 = old:326.932026 +  kp:0.550000 * e:-6.250000 + ki:0.000000 * sume:9163180.700228 + kd:0.040000 * (e:-6.250000 - e1:-6.250000)
[2026-08-08 20:29:49.329 UTC] [V] OFSCtrl CHG 29 q:3.000000, mod(round):0.000000
[2026-08-08 20:29:49.329 UTC] [D] OFSCtrl battery ctrl val:0.600000
[2026-08-08 20:29:49.330 UTC] [V] 485ChCtl <C3> battery limit on [3.000000,] request.
[2026-08-08 20:29:49.330 UTC] [V] OFSCtrl Control charge discharge proc:01->02->BATT_CHK->03->04->05->06->07->10->11->20->21->22->23->24->25->27->28->29->30->31->32->33->34
[2026-08-08 20:29:49.428 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:49.428 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:49.430 UTC] [V] 485ChCtl <C3> battery send request.1
[2026-08-08 20:29:49.430 UTC] [D] VarInf Limit_Bat rt[2]set val[3] set rate[0.600000] value100[500] value-100[-500]
[2026-08-08 20:29:49.432 UTC] [D] 485AcReq <C3:01> PutOStream [6][0f000001000000090110278e0001020003]
[2026-08-08 20:29:49.528 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:49.528 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:49.577 UTC] [V] 485DevCtl <C3:01> AnalyzeResponseData proc restart cnt:360509 UPRstat:0
[2026-08-08 20:29:49.580 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-08 20:29:49.581 UTC] [D] 485DevCtl <C3:01> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-08 20:29:49.581 UTC] [D] 485DevCtl <C3:01> ResCnd OperationId [6] IsNormal[1] 
[2026-08-08 20:29:49.581 UTC] [V] 485DevCtl <C3:01> device_type:Battery
[2026-08-08 20:29:49.581 UTC] [V] 485ChCtl <C3> set rt:0
[2026-08-08 20:29:49.627 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:49.628 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:49.679 UTC] [V] OFSCtrl [/var/local/solajithome/function/output_fluctuation_suppression/batt_data] write success.
[2026-08-08 20:29:49.727 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:49.728 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:49.827 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:49.828 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:49.928 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:49.928 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:50.028 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:50.028 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:50.128 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:50.128 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:50.228 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:50.228 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:50.328 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:50.328 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:50.328 UTC] [V] OFSCtrl Control charge discharge proc start.
[2026-08-08 20:29:50.328 UTC] [V] OFSCtrl CHG 20 p_th(t):-1109.900000 = p_th_old_:-1100.000000 + lev_cd_:-0.300000 * (total_pcs_capacity_:99000.000000 * cof_spec_:2.000000 / 60 * (time_threshold_renew:10.000000 * 10)), min:-1100.000000, max:119300.000000
[2026-08-08 20:29:50.329 UTC] [V] OFSCtrl CHG 21 batt_w:320.057026 = old:323.494526 +  kp:0.550000 * e:-6.250000 + ki:0.000000 * sume:9163174.450228 + kd:0.040000 * (e:-6.250000 - e1:-6.250000)
[2026-08-08 20:29:50.329 UTC] [V] OFSCtrl CHG 29 q:3.000000, mod(round):0.000000
[2026-08-08 20:29:50.329 UTC] [D] OFSCtrl battery ctrl val:0.600000
[2026-08-08 20:29:50.330 UTC] [V] 485ChCtl <C3> battery send request.1
[2026-08-08 20:29:50.330 UTC] [D] VarInf Limit_Bat rt[2]set val[3] set rate[0.600000] value100[500] value-100[-500]
[2026-08-08 20:29:50.331 UTC] [D] 485AcReq <C3:01> PutOStream [6][0f000001000000090110278e0001020003]
[2026-08-08 20:29:50.334 UTC] [V] 485ChCtl <C3> battery limit on [3.000000,] request.
[2026-08-08 20:29:50.334 UTC] [V] OFSCtrl Control charge discharge proc:01->02->BATT_CHK->03->04->05->06->07->10->11->20->21->22->23->24->25->27->28->29->30->31->32->33->34
[2026-08-08 20:29:50.393 UTC] [V] 485DevCtl <C1:01> device_type:Irr-Meter
[2026-08-08 20:29:50.393 UTC] [V] 485DevCtl <C1:01> device_type:Irr-Meter
[2026-08-08 20:29:50.393 UTC] [V] 485ChCtl <C1> fixed cycle Irr-Meter
[2026-08-08 20:29:50.393 UTC] [V] 485DevCtl <C1:01> Dev not PCS IsNeedToChangeOControlState
[2026-08-08 20:29:50.393 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :1
[2026-08-08 20:29:50.394 UTC] [V] 485ChCtl <C1> send request:Irr01
[2026-08-08 20:29:50.395 UTC] [D] 485AcReq <C1:01> PutOStream [1][080001040000000271cb]
[2026-08-08 20:29:50.428 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:50.428 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:50.497 UTC] [V] 485DevCtl <C3:01> AnalyzeResponseData proc restart cnt:360509 UPRstat:0
[2026-08-08 20:29:50.499 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-08 20:29:50.500 UTC] [D] 485DevCtl <C3:01> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-08 20:29:50.500 UTC] [D] 485DevCtl <C3:01> ResCnd OperationId [6] IsNormal[1] 
[2026-08-08 20:29:50.500 UTC] [V] 485DevCtl <C3:01> device_type:Battery
[2026-08-08 20:29:50.503 UTC] [V] 485ChCtl <C3> set rt:0
[2026-08-08 20:29:50.528 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:50.528 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:50.628 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:50.628 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:50.679 UTC] [V] OFSCtrl [/var/local/solajithome/function/output_fluctuation_suppression/batt_data] write success.
[2026-08-08 20:29:50.730 UTC] [V] 485ChCtl <C3> StartDeviceCommunicationForOutputFluctuationSuppressionControlBroadcast 4 cnt:3605153, monitor_cnt:50, bc_elapsed:3605153, min:10, max:40
[2026-08-08 20:29:50.730 UTC] [V] OFSCtrl /var/local/solajithome/function/output_fluctuation_suppression/state is exist:0
[2026-08-08 20:29:50.731 UTC] [V] 485DevCtl <C3:01> Dev not PCS IsNeedToChangeOControlState
[2026-08-08 20:29:50.731 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :1
[2026-08-08 20:29:50.732 UTC] [V] 485ChCtl <C3> send request:Sungrow11
[2026-08-08 20:29:50.732 UTC] [V] 485DevCtl <C1:01> AnalyzeResponseData proc restart cnt:360511 UPRstat:0
[2026-08-08 20:29:50.732 UTC] [V] Res no response condition. set normal condition.
[2026-08-08 20:29:50.733 UTC] [D] 485DevCtl <C1:01> RcvDat status[2] len[9] [010404000002013b24]
[2026-08-08 20:29:50.733 UTC] [D] 485DevCtl <C1:01> ResCnd OperationId [1] IsNormal[1] 
[2026-08-08 20:29:50.733 UTC] [V] OFSCtrl Rcv set flux_of_solar:0.000000
[2026-08-08 20:29:50.733 UTC] [V] 485DevCtl <C1:01> [01][401006][0.000000][1][W/m2]
[2026-08-08 20:29:50.733 UTC] [V] SummDat SetVrmValue dev_id:1 val:0.000000 sc:3
[2026-08-08 20:29:50.734 UTC] [V] OCMgr SetMeterValue PhId:0101, branchNo:01, valueId:401006, value:0.000000, scaleFactor:1, devId:1
[2026-08-08 20:29:50.734 UTC] [V] 485DevCtl <C1:01> [01][421005][263.000000][1][℃]
[2026-08-08 20:29:50.734 UTC] [V] SummDat SetVrmValue dev_id:1 val:26300.000000 sc:3
[2026-08-08 20:29:50.735 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:50.735 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:50.737 UTC] [D] 485AcReq <C3:01> PutOStream [1][0c00000100000006010327470048]
[2026-08-08 20:29:50.740 UTC] [V] OCMgr SetMeterValue PhId:0101, branchNo:01, valueId:421005, value:263.000000, scaleFactor:1, devId:1
[2026-08-08 20:29:50.741 UTC] [V] 485DevCtl <C1:01> device_type:Irr-Meter
[2026-08-08 20:29:50.741 UTC] [V] OFSCtrl Irr-Meter received.
[2026-08-08 20:29:50.756 UTC] [V] 485ChCtl <C1> set rt:0
[2026-08-08 20:29:50.767 UTC] [V] 485DevCtl <C1:01> device_type:Irr-Meter
[2026-08-08 20:29:50.794 UTC] [V] 485DevCtl <C1:04> device_type:CO-Meter
[2026-08-08 20:29:50.794 UTC] [V] 485DevCtl <C1:04> device_type:CO-Meter
[2026-08-08 20:29:50.795 UTC] [V] 485ChCtl <C1> fixed cycle CO-Meter
[2026-08-08 20:29:50.795 UTC] [V] 485DevCtl <C1:04> Dev not PCS IsNeedToChangeOControlState
[2026-08-08 20:29:50.795 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :1
[2026-08-08 20:29:50.796 UTC] [V] 485ChCtl <C1> send request:omron05
[2026-08-08 20:29:50.796 UTC] [D] 485AcReq <C1:04> PutOStream [1][0800040300030014b590]
[2026-08-08 20:29:50.827 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:50.827 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:50.927 UTC] [V] 485DevCtl <C3:01> AnalyzeResponseData proc restart cnt:360510 UPRstat:0
[2026-08-08 20:29:50.932 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:50.932 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:50.951 UTC] [D] 485DevCtl <C3:01> RcvDat status[0] len[153] [0001000000930103900001000200000000005500550000005500aa00a000fa000000fa0001000000000000000000000019ffffffffffffffffffffffffffffffffffffffffffff000100000000ffff0000ffffffffffffffffffffffffffffffffffff0fa0177003e800000e101388000a000a00000000195021c000000000000000550055ffe201f4ffff0000000000000000000000000003]
[2026-08-08 20:29:50.955 UTC] [D] 485DevCtl <C3:01> ResCnd OperationId [1] IsNormal[1]  ConditionType [lggrdev:Normal] Action[-1]
[2026-08-08 20:29:50.960 UTC] [V] 485DevCtl <C3:01> [01][753049][0.000000][0][]
[2026-08-08 20:29:50.962 UTC] [V] SummDat SetVrmValue dev_id:9 val:0.000000 sc:0
[2026-08-08 20:29:50.963 UTC] [V] OCMgr SetMeterValue PhId:0301, branchNo:01, valueId:753049, value:0.000000, scaleFactor:0, devId:9
[2026-08-08 20:29:50.963 UTC] [V] OFSCtrl Rcv set BATT(t-1)[0301]:0.006000 value:300.000000/50000 BATT(t-1):0.006000 <- 300.000000/50000
[2026-08-08 20:29:50.963 UTC] [V] 485DevCtl <C3:01> [01][753102][3.000000][1][kW]
[2026-08-08 20:29:50.963 UTC] [V] SummDat SetVrmValue dev_id:9 val:3.000000 sc:1
[2026-08-08 20:29:50.964 UTC] [V] OCMgr SetMeterValue PhId:0301, branchNo:01, valueId:753102, value:3.000000, scaleFactor:1, devId:9
[2026-08-08 20:29:50.964 UTC] [V] 485DevCtl <C3:01> device_type:Battery
[2026-08-08 20:29:51.003 UTC] [V] 485ChCtl <C3> set rt:0
[2026-08-08 20:29:51.004 UTC] [D] 485ChCtl <C3> monitoring dev All Send
[2026-08-08 20:29:51.028 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:51.028 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:51.128 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:51.128 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:51.201 UTC] [V] 485DevCtl <C1:04> AnalyzeResponseData proc restart cnt:360510 UPRstat:0
[2026-08-08 20:29:51.202 UTC] [V] Res no response condition. set normal condition.
[2026-08-08 20:29:51.203 UTC] [D] 485DevCtl <C1:04> RcvDat status[2] len[45] [0403280000222700001801000017ffffffffe500000258ffffe89fffffffc5ffffaf05ffffff3100121a811723]
[2026-08-08 20:29:51.203 UTC] [D] 485DevCtl <C1:04> ResCnd OperationId [1] IsNormal[1] 
[2026-08-08 20:29:51.204 UTC] [V] OFSCtrl Rcv set p_co:-590.000000, p_co_old:-610.000000
[2026-08-08 20:29:51.204 UTC] [V] 485DevCtl <C1:04> [01][601260][-59.000000][2][kW]
[2026-08-08 20:29:51.204 UTC] [V] SummDat SetVrmValue dev_id:4 val:-590.000000 sc:3
[2026-08-08 20:29:51.204 UTC] [V] OCMgr SetMeterValue PhId:0104, branchNo:01, valueId:601260, value:-59.000000, scaleFactor:2, devId:4
[2026-08-08 20:29:51.205 UTC] [V] 485DevCtl <C1:04> [01][603260][1186433.000000][1][kWh]
[2026-08-08 20:29:51.205 UTC] [V] SummDat SetVrmValue dev_id:4 val:1186433.000000 sc:1
[2026-08-08 20:29:51.205 UTC] [V] OCMgr SetMeterValue PhId:0104, branchNo:01, valueId:603260, value:1186433.000000, scaleFactor:1, devId:4
[2026-08-08 20:29:51.222 UTC] [V] 485DevCtl <C1:04> device_type:CO-Meter
[2026-08-08 20:29:51.228 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:51.228 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:51.223 UTC] [V] OFSCtrl km50 received.
[2026-08-08 20:29:51.231 UTC] [V] OFSCtrl omron05_local_date :2026/08/09 ? 2026/08/09
[2026-08-08 20:29:51.231 UTC] [V] OFSCtrl omron05_local_time :2026/08/09 05 ? 2026/08/09 05
[2026-08-08 20:29:51.234 UTC] [V] OFSCtrl out of control time.
[2026-08-08 20:29:51.235 UTC] [V] OFSCtrl Control pv-pcs proc start.
[2026-08-08 20:29:51.239 UTC] [V] OFSCtrl NOD_month:-1664.000000 = (NOD_month:306 - ((nod_max_/30):23.333333 * (cnt-1):25) * (30/cnt):6.000000 
[2026-08-08 20:29:51.246 UTC] [V] OFSCtrl PCS ratio_month:232.646617 = -k_inhibition_ratio_month:-0.097744 * NOD_month:-1664.000000 + inhibition_ratio_max:70
[2026-08-08 20:29:51.249 UTC] [V] OFSCtrl PCS 05 inhibition_ratio:70.000000 = max(ratio_min:5, min(ratio:70, ratio_hour:70.000000, ratio_day:70.000000, ratio_month:232.646617))
[2026-08-08 20:29:51.249 UTC] [D] OFSCtrl pv-pcs ctrl val:0.000000 old:0.000000
[2026-08-08 20:29:51.249 UTC] [V] OCHisDB set rate:0 t_rate:0 cnt:57
[2026-08-08 20:29:51.249 UTC] [V] 485ChCtl <C2> pv-pcs limit on [0.000000] request.
[2026-08-08 20:29:51.249 UTC] [V] OFSCtrl Control pv-pcs proc:BATT_CHK->01->02->03->04->05->06->07->09->09->10->11->12
[2026-08-08 20:29:51.249 UTC] [V] OFSCtrl Nod calc proc start.
[2026-08-08 20:29:51.249 UTC] [V] OFSCtrl ProcNodCountCalculation culc nod skip stop:0, pause:0, ctl_time:0
[2026-08-08 20:29:51.250 UTC] [V] OFSCtrl update p_co_old:-590.000000
[2026-08-08 20:29:51.250 UTC] [V] OFSCtrl Nod calc proc:
[2026-08-08 20:29:51.270 UTC] [V] 485ChCtl <C1> set rt:0
[2026-08-08 20:29:51.272 UTC] [V] 485DevCtl <C1:04> device_type:CO-Meter
[2026-08-08 20:29:51.309 UTC] [V] 485ChCtl <C2> pv-pcs send request.
[2026-08-08 20:29:51.310 UTC] [D] VarInf update ofs_rate:0.000000
[2026-08-08 20:29:51.310 UTC] [V] VarInf LimitSet rt[2] val[170] key[ValueOn]
[2026-08-08 20:29:51.310 UTC] [D] VarInf output_mode:8
[2026-08-08 20:29:51.310 UTC] [D] VarInf update ofs_rate:0.000000
[2026-08-08 20:29:51.310 UTC] [D] VarInf Limit setRate[0.000000] rate[0.000000] value100[1000.000000] value0[0.000000]
[2026-08-08 20:29:51.310 UTC] [V] 485DevCtl <C2:01> ChangeOutputRateToDevice rate:0.000000 set_rate1
[2026-08-08 20:29:51.310 UTC] [D] VarInf Limit rt[2] int_set_rate[1] server_rate[0.000000] rated_output[100.000000] solar_battery_power[100.000000]
[2026-08-08 20:29:51.313 UTC] [D] 485AcReq <C2:01> PutOStreamForBc [3][0d000010138e00020400aa0001466f]
[2026-08-08 20:29:51.328 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:51.328 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:51.328 UTC] [V] OFSCtrl Control charge discharge proc start.
[2026-08-08 20:29:51.328 UTC] [V] OFSCtrl CHG 20 p_th(t):-1109.900000 = p_th_old_:-1100.000000 + lev_cd_:-0.300000 * (total_pcs_capacity_:99000.000000 * cof_spec_:2.000000 / 60 * (time_threshold_renew:10.000000 * 10)), min:-1100.000000, max:119300.000000
[2026-08-08 20:29:51.329 UTC] [V] OFSCtrl CHG 21 batt_w:316.619526 = old:320.057026 +  kp:0.550000 * e:-6.250000 + ki:0.000000 * sume:9163168.200228 + kd:0.040000 * (e:-6.250000 - e1:-6.250000)
[2026-08-08 20:29:51.329 UTC] [V] OFSCtrl CHG 29 q:3.000000, mod(round):0.000000
[2026-08-08 20:29:51.329 UTC] [D] OFSCtrl battery ctrl val:0.600000
[2026-08-08 20:29:51.329 UTC] [V] 485ChCtl <C3> battery send request.1
[2026-08-08 20:29:51.330 UTC] [D] VarInf Limit_Bat rt[2]set val[3] set rate[0.600000] value100[500] value-100[-500]
[2026-08-08 20:29:51.331 UTC] [D] 485AcReq <C3:01> PutOStream [6][0f000001000000090110278e0001020003]
[2026-08-08 20:29:51.329 UTC] [V] 485ChCtl <C3> battery limit on [3.000000,] request.
[2026-08-08 20:29:51.335 UTC] [V] OFSCtrl Control charge discharge proc:01->02->BATT_CHK->03->04->05->06->07->10->11->20->21->22->23->24->25->27->28->29->30->31->32->33->34
[2026-08-08 20:29:51.428 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:51.428 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:51.477 UTC] [V] 485DevCtl <C3:01> AnalyzeResponseData proc restart cnt:360510 UPRstat:0
[2026-08-08 20:29:51.480 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-08 20:29:51.481 UTC] [D] 485DevCtl <C3:01> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-08 20:29:51.481 UTC] [D] 485DevCtl <C3:01> ResCnd OperationId [6] IsNormal[1] 
[2026-08-08 20:29:51.481 UTC] [V] 485DevCtl <C3:01> device_type:Battery
[2026-08-08 20:29:51.481 UTC] [V] 485ChCtl <C3> set rt:0
[2026-08-08 20:29:51.528 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:51.528 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:51.602 UTC] [V] 485ChCtl <C2> set rt:0
[2026-08-08 20:29:51.628 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:51.628 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:51.679 UTC] [V] OFSCtrl [/var/local/solajithome/function/output_fluctuation_suppression/batt_data] write success.
[2026-08-08 20:29:51.728 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:51.728 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:51.810 UTC] [V] 485ChCtl <C2> StartDeviceCommunicationForOutputFluctuationSuppressionControlBroadcast 4 cnt:3605164, monitor_cnt:50, bc_elapsed:3605164, min:10, max:40
[2026-08-08 20:29:51.810 UTC] [V] OFSCtrl /var/local/solajithome/function/output_fluctuation_suppression/state is exist:0
[2026-08-08 20:29:51.810 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :1
[2026-08-08 20:29:51.812 UTC] [V] 485ChCtl <C2> send request:Sungrow08
[2026-08-08 20:29:51.812 UTC] [D] 485AcReq <C2:01> PutOStream [1][08000104138a0024d57f]
[2026-08-08 20:29:51.828 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:51.828 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:51.928 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:51.928 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:52.028 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:52.028 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:52.128 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:52.128 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:52.212 UTC] [V] Res no response condition. set normal condition.
[2026-08-08 20:29:52.214 UTC] [D] 485DevCtl <C2:01> RcvDat status[2] len[77] [0104480000fcc00000172b000000000000000000000000000000000000000000000000000000000000000000000000ffffffffffffffffffffffff000000000000000000000000000014002f98]
[2026-08-08 20:29:52.214 UTC] [D] 485DevCtl <C2:01> ResCnd OperationId [1] IsNormal[1] 
[2026-08-08 20:29:52.214 UTC] [V] 485DevCtl <C2:01> [01][115202][0.000000][1][kWh]
[2026-08-08 20:29:52.214 UTC] [V] SummDat SetVrmValue dev_id:7 val:0.000000 sc:1
[2026-08-08 20:29:52.215 UTC] [V] OCMgr SetMeterValue PhId:0201, branchNo:01, valueId:115202, value:0.000000, scaleFactor:1, devId:7
[2026-08-08 20:29:52.215 UTC] [V] 485DevCtl <C2:01> [01][113202][64704.000000][0][kWh]
[2026-08-08 20:29:52.215 UTC] [V] SummDat SetVrmValue dev_id:7 val:64704.000000 sc:0
[2026-08-08 20:29:52.227 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:52.228 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:52.215 UTC] [V] OCMgr SetMeterValue PhId:0201, branchNo:01, valueId:113202, value:64704.000000, scaleFactor:0, devId:7
[2026-08-08 20:29:52.231 UTC] [V] 485DevCtl <C2:01> [01][121005][0.000000][1][℃]
[2026-08-08 20:29:52.232 UTC] [V] SummDat SetVrmValue dev_id:7 val:0.000000 sc:3
[2026-08-08 20:29:52.235 UTC] [V] OCMgr SetMeterValue PhId:0201, branchNo:01, valueId:121005, value:0.000000, scaleFactor:1, devId:7
[2026-08-08 20:29:52.237 UTC] [V] 485DevCtl <C2:01> [01][101100][0.000000][1][V]
[2026-08-08 20:29:52.240 UTC] [V] SummDat SetVrmValue dev_id:7 val:0.000000 sc:3
[2026-08-08 20:29:52.246 UTC] [V] OCMgr SetMeterValue PhId:0201, branchNo:01, valueId:101100, value:0.000000, scaleFactor:1, devId:7
[2026-08-08 20:29:52.252 UTC] [V] 485DevCtl <C2:01> [01][101101][0.000000][1][A]
[2026-08-08 20:29:52.257 UTC] [V] SummDat SetVrmValue dev_id:7 val:0.000000 sc:3
[2026-08-08 20:29:52.257 UTC] [V] OCMgr SetMeterValue PhId:0201, branchNo:01, valueId:101101, value:0.000000, scaleFactor:1, devId:7
[2026-08-08 20:29:52.257 UTC] [V] 485DevCtl <C2:01> [02][101100][0.000000][1][V]
[2026-08-08 20:29:52.259 UTC] [V] SummDat SetVrmValue dev_id:7 val:0.000000 sc:3
[2026-08-08 20:29:52.264 UTC] [V] OCMgr SetMeterValue PhId:0201, branchNo:02, valueId:101100, value:0.000000, scaleFactor:1, devId:7
[2026-08-08 20:29:52.270 UTC] [V] 485DevCtl <C2:01> [02][101101][0.000000][1][A]
[2026-08-08 20:29:52.274 UTC] [V] SummDat SetVrmValue dev_id:7 val:0.000000 sc:3
[2026-08-08 20:29:52.275 UTC] [V] OCMgr SetMeterValue PhId:0201, branchNo:02, valueId:101101, value:0.000000, scaleFactor:1, devId:7
[2026-08-08 20:29:52.276 UTC] [V] 485DevCtl <C2:01> [03][101100][0.000000][1][V]
[2026-08-08 20:29:52.276 UTC] [V] SummDat SetVrmValue dev_id:7 val:0.000000 sc:3
[2026-08-08 20:29:52.276 UTC] [V] OCMgr SetMeterValue PhId:0201, branchNo:03, valueId:101100, value:0.000000, scaleFactor:1, devId:7
[2026-08-08 20:29:52.276 UTC] [V] 485DevCtl <C2:01> [03][101101][0.000000][1][A]
[2026-08-08 20:29:52.276 UTC] [V] SummDat SetVrmValue dev_id:7 val:0.000000 sc:3
[2026-08-08 20:29:52.289 UTC] [V] OCMgr SetMeterValue PhId:0201, branchNo:03, valueId:101101, value:0.000000, scaleFactor:1, devId:7
[2026-08-08 20:29:52.295 UTC] [V] 485DevCtl <C2:01> [01][101102][0.000000][0][W]
[2026-08-08 20:29:52.298 UTC] [V] SummDat SetVrmValue dev_id:7 val:0.000000 sc:3
[2026-08-08 20:29:52.302 UTC] [V] OCMgr SetMeterValue PhId:0201, branchNo:01, valueId:101102, value:0.000000, scaleFactor:0, devId:7
[2026-08-08 20:29:52.302 UTC] [V] 485DevCtl <C2:01> [01][111200][0.000000][1][V]
[2026-08-08 20:29:52.302 UTC] [V] SummDat SetVrmValue dev_id:7 val:0.000000 sc:3
[2026-08-08 20:29:52.303 UTC] [V] OCMgr SetMeterValue PhId:0201, branchNo:01, valueId:111200, value:0.000000, scaleFactor:1, devId:7
[2026-08-08 20:29:52.303 UTC] [V] 485DevCtl <C2:01> [02][111200][0.000000][1][V]
[2026-08-08 20:29:52.303 UTC] [V] SummDat SetVrmValue dev_id:7 val:0.000000 sc:3
[2026-08-08 20:29:52.303 UTC] [V] OCMgr SetMeterValue PhId:0201, branchNo:02, valueId:111200, value:0.000000, scaleFactor:1, devId:7
[2026-08-08 20:29:52.303 UTC] [V] 485DevCtl <C2:01> [03][111200][0.000000][1][V]
[2026-08-08 20:29:52.304 UTC] [V] SummDat SetVrmValue dev_id:7 val:0.000000 sc:3
[2026-08-08 20:29:52.304 UTC] [V] OCMgr SetMeterValue PhId:0201, branchNo:03, valueId:111200, value:0.000000, scaleFactor:1, devId:7
[2026-08-08 20:29:52.304 UTC] [V] 485DevCtl <C2:01> [01][111201][0.000000][1][A]
[2026-08-08 20:29:52.304 UTC] [V] SummDat SetVrmValue dev_id:7 val:0.000000 sc:3
[2026-08-08 20:29:52.304 UTC] [V] OCMgr SetMeterValue PhId:0201, branchNo:01, valueId:111201, value:0.000000, scaleFactor:1, devId:7
[2026-08-08 20:29:52.324 UTC] [V] 485DevCtl <C2:01> [02][111201][0.000000][1][A]
[2026-08-08 20:29:52.327 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:52.327 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:52.328 UTC] [V] OFSCtrl Control charge discharge proc start.
[2026-08-08 20:29:52.328 UTC] [V] OFSCtrl CHG 20 p_th(t):-1109.900000 = p_th_old_:-1100.000000 + lev_cd_:-0.300000 * (total_pcs_capacity_:99000.000000 * cof_spec_:2.000000 / 60 * (time_threshold_renew:10.000000 * 10)), min:-1100.000000, max:119300.000000
[2026-08-08 20:29:52.328 UTC] [V] OFSCtrl CHG 21 batt_w:313.182026 = old:316.619526 +  kp:0.550000 * e:-6.250000 + ki:0.000000 * sume:9163161.950228 + kd:0.040000 * (e:-6.250000 - e1:-6.250000)
[2026-08-08 20:29:52.329 UTC] [V] OFSCtrl CHG 29 q:3.000000, mod(round):0.000000
[2026-08-08 20:29:52.329 UTC] [D] OFSCtrl battery ctrl val:0.600000
[2026-08-08 20:29:52.329 UTC] [V] 485ChCtl <C3> battery limit on [3.000000,] request.
[2026-08-08 20:29:52.330 UTC] [V] OFSCtrl Control charge discharge proc:01->02->BATT_CHK->03->04->05->06->07->10->11->20->21->22->23->24->25->27->28->29->30->31->32->33->34
[2026-08-08 20:29:52.331 UTC] [V] SummDat SetVrmValue dev_id:7 val:0.000000 sc:3
[2026-08-08 20:29:52.331 UTC] [V] OCMgr SetMeterValue PhId:0201, branchNo:02, valueId:111201, value:0.000000, scaleFactor:1, devId:7
[2026-08-08 20:29:52.332 UTC] [V] 485DevCtl <C2:01> [03][111201][0.000000][1][A]
[2026-08-08 20:29:52.343 UTC] [V] SummDat SetVrmValue dev_id:7 val:0.000000 sc:3
[2026-08-08 20:29:52.345 UTC] [V] OCMgr SetMeterValue PhId:0201, branchNo:03, valueId:111201, value:0.000000, scaleFactor:1, devId:7
[2026-08-08 20:29:52.346 UTC] [V] 485DevCtl <C2:01> [01][111202][0.000000][0][W]
[2026-08-08 20:29:52.347 UTC] [V] SummDat SetVrmValue dev_id:7 val:0.000000 sc:3
[2026-08-08 20:29:52.353 UTC] [V] OCMgr SetMeterValue PhId:0201, branchNo:01, valueId:111202, value:0.000000, scaleFactor:0, devId:7
[2026-08-08 20:29:52.356 UTC] [V] 485DevCtl <C2:01> [01][111203][0.000000][0][var]
[2026-08-08 20:29:52.357 UTC] [V] SummDat SetVrmValue dev_id:7 val:0.000000 sc:3
[2026-08-08 20:29:52.361 UTC] [V] OCMgr SetMeterValue PhId:0201, branchNo:01, valueId:111203, value:0.000000, scaleFactor:0, devId:7
[2026-08-08 20:29:52.365 UTC] [V] 485DevCtl <C2:01> [01][121007][0.000000][3][]
[2026-08-08 20:29:52.366 UTC] [V] SummDat SetVrmValue dev_id:7 val:0.000000 sc:3
[2026-08-08 20:29:52.370 UTC] [V] OCMgr SetMeterValue PhId:0201, branchNo:01, valueId:121007, value:0.000000, scaleFactor:3, devId:7
[2026-08-08 20:29:52.375 UTC] [V] 485DevCtl <C2:01> [01][131006][0.000000][1][Hz]
[2026-08-08 20:29:52.376 UTC] [V] SummDat SetVrmValue dev_id:7 val:0.000000 sc:3
[2026-08-08 20:29:52.379 UTC] [V] OCMgr SetMeterValue PhId:0201, branchNo:01, valueId:131006, value:0.000000, scaleFactor:1, devId:7
[2026-08-08 20:29:52.379 UTC] [V] 485DevCtl <C2:01> [01][114202][64704.000000][0][kWh]
[2026-08-08 20:29:52.379 UTC] [V] SummDat SetVrmValue dev_id:7 val:64704000.000000 sc:3
[2026-08-08 20:29:52.387 UTC] [V] OCMgr SetMeterValue PhId:0201, branchNo:01, valueId:114202, value:64704.000000, scaleFactor:0, devId:7
[2026-08-08 20:29:52.389 UTC] [V] 485DevCtl <C2:01> device_type:PV-PCS
[2026-08-08 20:29:52.396 UTC] [V] 485DevCtl <C2:01> set2 StatusCode[010100] DeviceName[] DeviceNumber[]
[2026-08-08 20:29:52.400 UTC] [V] 485ChCtl <C2> set rt:0
[2026-08-08 20:29:52.409 UTC] [V] 485ChCtl <C2> StartDeviceCommunicationForOutputFluctuationSuppressionControlBroadcast 4 cnt:3605170, monitor_cnt:56, bc_elapsed:3605170, min:10, max:40
[2026-08-08 20:29:52.410 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :9
[2026-08-08 20:29:52.410 UTC] [V] 485ChCtl <C2> send request:Sungrow08
[2026-08-08 20:29:52.411 UTC] [D] 485AcReq <C2:02> PutOStream [9][0800020413fa00179482]
[2026-08-08 20:29:52.427 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:52.428 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:52.429 UTC] [V] 485ChCtl <C3> battery send request.1
[2026-08-08 20:29:52.430 UTC] [D] VarInf Limit_Bat rt[2]set val[3] set rate[0.600000] value100[500] value-100[-500]
[2026-08-08 20:29:52.431 UTC] [D] 485AcReq <C3:01> PutOStream [6][0f000001000000090110278e0001020003]
[2026-08-08 20:29:52.528 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:52.528 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:52.597 UTC] [V] 485DevCtl <C3:01> AnalyzeResponseData proc restart cnt:360512 UPRstat:0
[2026-08-08 20:29:52.599 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-08 20:29:52.599 UTC] [D] 485DevCtl <C3:01> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-08 20:29:52.599 UTC] [D] 485DevCtl <C3:01> ResCnd OperationId [6] IsNormal[1] 
[2026-08-08 20:29:52.600 UTC] [V] 485DevCtl <C3:01> device_type:Battery
[2026-08-08 20:29:52.600 UTC] [V] 485ChCtl <C3> set rt:0
[2026-08-08 20:29:52.628 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:52.628 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:52.679 UTC] [V] OFSCtrl [/var/local/solajithome/function/output_fluctuation_suppression/batt_data] write success.
[2026-08-08 20:29:52.728 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:52.728 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:52.798 UTC] [V] Res no response condition. set normal condition.
[2026-08-08 20:29:52.800 UTC] [D] 485DevCtl <C2:02> RcvDat status[2] len[51] [02042e000000000000000000000000ffffffffffffffff03e8ffffffff420e0000ffffffffffffffffffffffffffffffff914e]
[2026-08-08 20:29:52.800 UTC] [D] 485DevCtl <C2:02> ResCnd OperationId [9] IsNormal[1] 
[2026-08-08 20:29:52.801 UTC] [V] 485DevCtl <C2:02> [04][101100][0.000000][1][V]
[2026-08-08 20:29:52.801 UTC] [V] SummDat SetVrmValue dev_id:8 val:0.000000 sc:3
[2026-08-08 20:29:52.801 UTC] [V] OCMgr SetMeterValue PhId:0202, branchNo:04, valueId:101100, value:0.000000, scaleFactor:1, devId:8
[2026-08-08 20:29:52.801 UTC] [V] 485DevCtl <C2:02> [04][101101][0.000000][1][A]
[2026-08-08 20:29:52.801 UTC] [V] SummDat SetVrmValue dev_id:8 val:0.000000 sc:3
[2026-08-08 20:29:52.802 UTC] [V] OCMgr SetMeterValue PhId:0202, branchNo:04, valueId:101101, value:0.000000, scaleFactor:1, devId:8
[2026-08-08 20:29:52.813 UTC] [V] 485DevCtl <C2:02> [05][101100][0.000000][1][V]
[2026-08-08 20:29:52.817 UTC] [V] SummDat SetVrmValue dev_id:8 val:0.000000 sc:3
[2026-08-08 20:29:52.820 UTC] [V] OCMgr SetMeterValue PhId:0202, branchNo:05, valueId:101100, value:0.000000, scaleFactor:1, devId:8
[2026-08-08 20:29:52.820 UTC] [V] 485DevCtl <C2:02> [05][101101][0.000000][1][A]
[2026-08-08 20:29:52.820 UTC] [V] SummDat SetVrmValue dev_id:8 val:0.000000 sc:3
[2026-08-08 20:29:52.820 UTC] [V] OCMgr SetMeterValue PhId:0202, branchNo:05, valueId:101101, value:0.000000, scaleFactor:1, devId:8
[2026-08-08 20:29:52.821 UTC] [V] 485DevCtl <C2:02> [06][101100][0.000000][1][V]
[2026-08-08 20:29:52.821 UTC] [V] SummDat SetVrmValue dev_id:8 val:0.000000 sc:3
[2026-08-08 20:29:52.821 UTC] [V] OCMgr SetMeterValue PhId:0202, branchNo:06, valueId:101100, value:0.000000, scaleFactor:1, devId:8
[2026-08-08 20:29:52.821 UTC] [V] 485DevCtl <C2:02> [06][101101][0.000000][1][A]
[2026-08-08 20:29:52.821 UTC] [V] SummDat SetVrmValue dev_id:8 val:0.000000 sc:3
[2026-08-08 20:29:52.822 UTC] [V] OCMgr SetMeterValue PhId:0202, branchNo:06, valueId:101101, value:0.000000, scaleFactor:1, devId:8
[2026-08-08 20:29:52.828 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:52.828 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:52.846 UTC] [V] 485DevCtl <C2:02> device_type:PV-PCS
[2026-08-08 20:29:52.846 UTC] [V] 485ChCtl <C2> set rt:0
[2026-08-08 20:29:52.852 UTC] [D] 485ChCtl <C2> monitoring dev All Send
[2026-08-08 20:29:52.928 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:52.929 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:53.027 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:53.027 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:53.127 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:53.129 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:53.227 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:53.228 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:53.328 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:53.328 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:53.328 UTC] [V] OFSCtrl Control charge discharge proc start.
[2026-08-08 20:29:53.328 UTC] [V] OFSCtrl CHG 20 p_th(t):-1109.900000 = p_th_old_:-1100.000000 + lev_cd_:-0.300000 * (total_pcs_capacity_:99000.000000 * cof_spec_:2.000000 / 60 * (time_threshold_renew:10.000000 * 10)), min:-1100.000000, max:119300.000000
[2026-08-08 20:29:53.329 UTC] [V] OFSCtrl CHG 21 batt_w:309.744526 = old:313.182026 +  kp:0.550000 * e:-6.250000 + ki:0.000000 * sume:9163155.700228 + kd:0.040000 * (e:-6.250000 - e1:-6.250000)
[2026-08-08 20:29:53.330 UTC] [V] OFSCtrl CHG 29 q:3.000000, mod(round):0.000000
[2026-08-08 20:29:53.330 UTC] [D] OFSCtrl battery ctrl val:0.600000
[2026-08-08 20:29:53.330 UTC] [V] 485ChCtl <C3> battery limit on [3.000000,] request.
[2026-08-08 20:29:53.330 UTC] [V] OFSCtrl Control charge discharge proc:01->02->BATT_CHK->03->04->05->06->07->10->11->20->21->22->23->24->25->27->28->29->30->31->32->33->34
[2026-08-08 20:29:53.428 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:53.428 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:53.429 UTC] [V] 485ChCtl <C3> battery send request.1
[2026-08-08 20:29:53.430 UTC] [D] VarInf Limit_Bat rt[2]set val[3] set rate[0.600000] value100[500] value-100[-500]
[2026-08-08 20:29:53.431 UTC] [D] 485AcReq <C3:01> PutOStream [6][0f000001000000090110278e0001020003]
[2026-08-08 20:29:53.528 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:53.528 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:53.577 UTC] [V] 485DevCtl <C3:01> AnalyzeResponseData proc restart cnt:360513 UPRstat:0
[2026-08-08 20:29:53.579 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-08 20:29:53.580 UTC] [D] 485DevCtl <C3:01> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-08 20:29:53.580 UTC] [D] 485DevCtl <C3:01> ResCnd OperationId [6] IsNormal[1] 
[2026-08-08 20:29:53.580 UTC] [V] 485DevCtl <C3:01> device_type:Battery
[2026-08-08 20:29:53.580 UTC] [V] 485ChCtl <C3> set rt:0
[2026-08-08 20:29:53.628 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:53.628 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:53.679 UTC] [V] OFSCtrl [/var/local/solajithome/function/output_fluctuation_suppression/batt_data] write success.
[2026-08-08 20:29:53.727 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:53.728 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:53.827 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:53.828 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:53.927 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:53.928 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:54.027 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:54.028 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:54.127 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:54.128 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:54.227 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:54.228 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:54.327 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:54.327 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:54.328 UTC] [V] OFSCtrl Control charge discharge proc start.
[2026-08-08 20:29:54.328 UTC] [V] OFSCtrl CHG 20 p_th(t):-1109.900000 = p_th_old_:-1100.000000 + lev_cd_:-0.300000 * (total_pcs_capacity_:99000.000000 * cof_spec_:2.000000 / 60 * (time_threshold_renew:10.000000 * 10)), min:-1100.000000, max:119300.000000
[2026-08-08 20:29:54.328 UTC] [V] OFSCtrl CHG 21 batt_w:306.307026 = old:309.744526 +  kp:0.550000 * e:-6.250000 + ki:0.000000 * sume:9163149.450228 + kd:0.040000 * (e:-6.250000 - e1:-6.250000)
[2026-08-08 20:29:54.329 UTC] [V] OFSCtrl CHG 29 q:3.000000, mod(round):0.000000
[2026-08-08 20:29:54.329 UTC] [D] OFSCtrl battery ctrl val:0.600000
[2026-08-08 20:29:54.329 UTC] [V] 485ChCtl <C3> battery limit on [3.000000,] request.
[2026-08-08 20:29:54.329 UTC] [V] OFSCtrl Control charge discharge proc:01->02->BATT_CHK->03->04->05->06->07->10->11->20->21->22->23->24->25->27->28->29->30->31->32->33->34
[2026-08-08 20:29:54.330 UTC] [V] 485ChCtl <C3> battery send request.1
[2026-08-08 20:29:54.330 UTC] [D] VarInf Limit_Bat rt[2]set val[3] set rate[0.600000] value100[500] value-100[-500]
[2026-08-08 20:29:54.332 UTC] [D] 485AcReq <C3:01> PutOStream [6][0f000001000000090110278e0001020003]
[2026-08-08 20:29:54.428 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:54.428 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:54.487 UTC] [V] 485DevCtl <C3:01> AnalyzeResponseData proc restart cnt:360513 UPRstat:0
[2026-08-08 20:29:54.490 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-08 20:29:54.491 UTC] [D] 485DevCtl <C3:01> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-08 20:29:54.491 UTC] [D] 485DevCtl <C3:01> ResCnd OperationId [6] IsNormal[1] 
[2026-08-08 20:29:54.491 UTC] [V] 485DevCtl <C3:01> device_type:Battery
[2026-08-08 20:29:54.491 UTC] [V] 485ChCtl <C3> set rt:0
[2026-08-08 20:29:54.528 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:54.528 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:54.628 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:54.628 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:54.679 UTC] [V] OFSCtrl [/var/local/solajithome/function/output_fluctuation_suppression/batt_data] write success.
[2026-08-08 20:29:54.728 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:54.728 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:54.828 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:54.828 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:54.927 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:54.928 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:55.028 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:55.028 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:55.128 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:55.128 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:55.228 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:55.228 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:55.328 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:55.328 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:55.328 UTC] [V] OFSCtrl Control charge discharge proc start.
[2026-08-08 20:29:55.328 UTC] [V] OFSCtrl CHG 20 p_th(t):-1109.900000 = p_th_old_:-1100.000000 + lev_cd_:-0.300000 * (total_pcs_capacity_:99000.000000 * cof_spec_:2.000000 / 60 * (time_threshold_renew:10.000000 * 10)), min:-1100.000000, max:119300.000000
[2026-08-08 20:29:55.329 UTC] [V] OFSCtrl CHG 21 batt_w:302.869526 = old:306.307026 +  kp:0.550000 * e:-6.250000 + ki:0.000000 * sume:9163143.200228 + kd:0.040000 * (e:-6.250000 - e1:-6.250000)
[2026-08-08 20:29:55.329 UTC] [V] OFSCtrl CHG 29 q:3.000000, mod(round):0.000000
[2026-08-08 20:29:55.329 UTC] [D] OFSCtrl battery ctrl val:0.600000
[2026-08-08 20:29:55.329 UTC] [V] 485ChCtl <C3> battery limit on [3.000000,] request.
[2026-08-08 20:29:55.330 UTC] [V] OFSCtrl Control charge discharge proc:01->02->BATT_CHK->03->04->05->06->07->10->11->20->21->22->23->24->25->27->28->29->30->31->32->33->34
[2026-08-08 20:29:55.393 UTC] [V] 485DevCtl <C1:01> device_type:Irr-Meter
[2026-08-08 20:29:55.393 UTC] [V] 485DevCtl <C1:01> device_type:Irr-Meter
[2026-08-08 20:29:55.393 UTC] [V] 485ChCtl <C1> fixed cycle Irr-Meter
[2026-08-08 20:29:55.393 UTC] [V] 485DevCtl <C1:01> Dev not PCS IsNeedToChangeOControlState
[2026-08-08 20:29:55.393 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :1
[2026-08-08 20:29:55.394 UTC] [V] 485ChCtl <C1> send request:Irr01
[2026-08-08 20:29:55.395 UTC] [D] 485AcReq <C1:01> PutOStream [1][080001040000000271cb]
[2026-08-08 20:29:55.427 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:55.427 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:55.429 UTC] [V] 485ChCtl <C3> battery send request.1
[2026-08-08 20:29:55.430 UTC] [D] VarInf Limit_Bat rt[2]set val[3] set rate[0.600000] value100[500] value-100[-500]
[2026-08-08 20:29:55.431 UTC] [D] 485AcReq <C3:01> PutOStream [6][0f000001000000090110278e0001020003]
[2026-08-08 20:29:55.527 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:55.527 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:55.587 UTC] [V] 485DevCtl <C3:01> AnalyzeResponseData proc restart cnt:360515 UPRstat:0
[2026-08-08 20:29:55.590 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-08 20:29:55.591 UTC] [D] 485DevCtl <C3:01> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-08 20:29:55.591 UTC] [D] 485DevCtl <C3:01> ResCnd OperationId [6] IsNormal[1] 
[2026-08-08 20:29:55.591 UTC] [V] 485DevCtl <C3:01> device_type:Battery
[2026-08-08 20:29:55.591 UTC] [V] 485ChCtl <C3> set rt:0
[2026-08-08 20:29:55.628 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:55.628 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:55.679 UTC] [V] OFSCtrl [/var/local/solajithome/function/output_fluctuation_suppression/batt_data] write success.
[2026-08-08 20:29:55.728 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:55.728 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:55.729 UTC] [V] 485DevCtl <C1:01> AnalyzeResponseData proc restart cnt:360516 UPRstat:0
[2026-08-08 20:29:55.729 UTC] [V] Res no response condition. set normal condition.
[2026-08-08 20:29:55.729 UTC] [D] 485DevCtl <C1:01> RcvDat status[2] len[9] [010404000002013b24]
[2026-08-08 20:29:55.729 UTC] [D] 485DevCtl <C1:01> ResCnd OperationId [1] IsNormal[1] 
[2026-08-08 20:29:55.730 UTC] [V] 485ChCtl <C3> StartDeviceCommunicationForOutputFluctuationSuppressionControlBroadcast 4 cnt:3605203, monitor_cnt:50, bc_elapsed:3605203, min:10, max:40
[2026-08-08 20:29:55.730 UTC] [V] OFSCtrl /var/local/solajithome/function/output_fluctuation_suppression/state is exist:0
[2026-08-08 20:29:55.730 UTC] [V] 485DevCtl <C3:01> Dev not PCS IsNeedToChangeOControlState
[2026-08-08 20:29:55.730 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :2
[2026-08-08 20:29:55.734 UTC] [V] OFSCtrl Rcv set flux_of_solar:0.000000
[2026-08-08 20:29:55.734 UTC] [V] 485DevCtl <C1:01> [01][401006][0.000000][1][W/m2]
[2026-08-08 20:29:55.734 UTC] [V] SummDat SetVrmValue dev_id:1 val:0.000000 sc:3
[2026-08-08 20:29:55.735 UTC] [V] OCMgr SetMeterValue PhId:0101, branchNo:01, valueId:401006, value:0.000000, scaleFactor:1, devId:1
[2026-08-08 20:29:55.735 UTC] [V] 485DevCtl <C1:01> [01][421005][263.000000][1][℃]
[2026-08-08 20:29:55.734 UTC] [V] 485ChCtl <C3> send request:Sungrow11
[2026-08-08 20:29:55.736 UTC] [D] 485AcReq <C3:01> PutOStream [2][0c0000010000000601042751005e]
[2026-08-08 20:29:55.735 UTC] [V] SummDat SetVrmValue dev_id:1 val:26300.000000 sc:3
[2026-08-08 20:29:55.743 UTC] [V] OCMgr SetMeterValue PhId:0101, branchNo:01, valueId:421005, value:263.000000, scaleFactor:1, devId:1
[2026-08-08 20:29:55.748 UTC] [V] 485DevCtl <C1:01> device_type:Irr-Meter
[2026-08-08 20:29:55.749 UTC] [V] OFSCtrl Irr-Meter received.
[2026-08-08 20:29:55.767 UTC] [V] 485ChCtl <C1> set rt:0
[2026-08-08 20:29:55.769 UTC] [V] 485DevCtl <C1:01> device_type:Irr-Meter
[2026-08-08 20:29:55.792 UTC] [V] 485DevCtl <C1:04> device_type:CO-Meter
[2026-08-08 20:29:55.793 UTC] [V] 485DevCtl <C1:04> device_type:CO-Meter
[2026-08-08 20:29:55.793 UTC] [V] 485ChCtl <C1> fixed cycle CO-Meter
[2026-08-08 20:29:55.793 UTC] [V] 485DevCtl <C1:04> Dev not PCS IsNeedToChangeOControlState
[2026-08-08 20:29:55.793 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :1
[2026-08-08 20:29:55.794 UTC] [V] 485ChCtl <C1> send request:omron05
[2026-08-08 20:29:55.796 UTC] [D] 485AcReq <C1:04> PutOStream [1][0800040300030014b590]
[2026-08-08 20:29:55.828 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:55.828 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:55.917 UTC] [V] 485DevCtl <C3:01> AnalyzeResponseData proc restart cnt:360515 UPRstat:0
[2026-08-08 20:29:55.928 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:55.928 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:55.956 UTC] [D] 485DevCtl <C3:01> RcvDat status[0] len[197] [0001000000bf0104bc0000ffffffffffff03cc00000000001000000000000000000000000000000000000000ae0032009a0000000100010001ffffffffffffffffffffffffffffffffffffffff000100000001000000010000ffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffff000101f40000000300000000000003e89df70000917100000000000000940000]
[2026-08-08 20:29:55.957 UTC] [D] 485DevCtl <C3:01> ResCnd OperationId [2] IsNormal[1]  ConditionType [lggrdev:Normal] Action[-1]
[2026-08-08 20:29:55.975 UTC] [V] 485DevCtl <C3:01> [02][753049][0.000000][0][]
[2026-08-08 20:29:55.976 UTC] [V] SummDat SetVrmValue dev_id:9 val:0.000000 sc:0
[2026-08-08 20:29:55.983 UTC] [V] OCMgr SetMeterValue PhId:0301, branchNo:02, valueId:753049, value:0.000000, scaleFactor:0, devId:9
[2026-08-08 20:29:55.984 UTC] [V] 485DevCtl <C3:01> [01][753040][16.000000][0][]
[2026-08-08 20:29:55.991 UTC] [V] SummDat SetVrmValue dev_id:9 val:16.000000 sc:0
[2026-08-08 20:29:55.992 UTC] [V] OCMgr SetMeterValue PhId:0301, branchNo:01, valueId:753040, value:16.000000, scaleFactor:0, devId:9
[2026-08-08 20:29:55.992 UTC] [V] 485DevCtl <C3:01> [01][753053][0.000000][0][]
[2026-08-08 20:29:55.992 UTC] [V] SummDat SetVrmValue dev_id:9 val:0.000000 sc:0
[2026-08-08 20:29:55.993 UTC] [V] OCMgr SetMeterValue PhId:0301, branchNo:01, valueId:753053, value:0.000000, scaleFactor:0, devId:9
[2026-08-08 20:29:55.993 UTC] [V] 485DevCtl <C3:01> [02][753053][0.000000][0][]
[2026-08-08 20:29:55.993 UTC] [V] SummDat SetVrmValue dev_id:9 val:0.000000 sc:0
[2026-08-08 20:29:55.993 UTC] [V] OCMgr SetMeterValue PhId:0301, branchNo:02, valueId:753053, value:0.000000, scaleFactor:0, devId:9
[2026-08-08 20:29:55.993 UTC] [V] 485DevCtl <C3:01> [03][753053][0.000000][0][]
[2026-08-08 20:29:55.993 UTC] [V] SummDat SetVrmValue dev_id:9 val:0.000000 sc:0
[2026-08-08 20:29:55.994 UTC] [V] OCMgr SetMeterValue PhId:0301, branchNo:03, valueId:753053, value:0.000000, scaleFactor:0, devId:9
[2026-08-08 20:29:55.994 UTC] [V] 485DevCtl <C3:01> [04][753053][0.000000][0][]
[2026-08-08 20:29:55.994 UTC] [V] SummDat SetVrmValue dev_id:9 val:0.000000 sc:0
[2026-08-08 20:29:55.994 UTC] [V] OCMgr SetMeterValue PhId:0301, branchNo:04, valueId:753053, value:0.000000, scaleFactor:0, devId:9
[2026-08-08 20:29:56.026 UTC] [V] 485DevCtl <C3:01> [01][716202][500.000000][1][kW]
[2026-08-08 20:29:56.028 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:56.028 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:56.029 UTC] [V] SummDat SetVrmValue dev_id:9 val:50.000000 sc:0
[2026-08-08 20:29:56.038 UTC] [V] OCMgr SetMeterValue PhId:0301, branchNo:01, valueId:716202, value:500.000000, scaleFactor:1, devId:9
[2026-08-08 20:29:56.038 UTC] [V] 485DevCtl <C3:01> [01][711102][3.000000][1][kW]
[2026-08-08 20:29:56.038 UTC] [V] SummDat SetVrmValue dev_id:9 val:300.000000 sc:3
[2026-08-08 20:29:56.038 UTC] [V] OCMgr SetMeterValue PhId:0301, branchNo:01, valueId:711102, value:3.000000, scaleFactor:1, devId:9
[2026-08-08 20:29:56.039 UTC] [V] 485DevCtl <C3:01> [01][703102][40439.000000][0][kWh]
[2026-08-08 20:29:56.039 UTC] [V] SummDat SetVrmValue dev_id:9 val:40439.000000 sc:0
[2026-08-08 20:29:56.039 UTC] [V] OCMgr SetMeterValue PhId:0301, branchNo:01, valueId:703102, value:40439.000000, scaleFactor:0, devId:9
[2026-08-08 20:29:56.039 UTC] [V] 485DevCtl <C3:01> [01][713102][37233.000000][0][kWh]
[2026-08-08 20:29:56.039 UTC] [V] SummDat SetVrmValue dev_id:9 val:37233.000000 sc:0
[2026-08-08 20:29:56.040 UTC] [V] OCMgr SetMeterValue PhId:0301, branchNo:01, valueId:713102, value:37233.000000, scaleFactor:0, devId:9
[2026-08-08 20:29:56.040 UTC] [V] 485DevCtl <C3:01> device_type:Battery
[2026-08-08 20:29:56.041 UTC] [V] 485ChCtl <C3> set rt:0
[2026-08-08 20:29:56.065 UTC] [D] 485ChCtl <C3> monitoring dev All Send
[2026-08-08 20:29:56.127 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:56.128 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:56.200 UTC] [V] 485DevCtl <C1:04> AnalyzeResponseData proc restart cnt:360515 UPRstat:0
[2026-08-08 20:29:56.201 UTC] [V] Res no response condition. set normal condition.
[2026-08-08 20:29:56.202 UTC] [D] 485DevCtl <C1:04> RcvDat status[2] len[45] [0403280000223000001809000017fdffffffe500000258ffffe8bcffffffc5ffffaef6ffffff3100121a81d219]
[2026-08-08 20:29:56.202 UTC] [D] 485DevCtl <C1:04> ResCnd OperationId [1] IsNormal[1] 
[2026-08-08 20:29:56.203 UTC] [V] OFSCtrl Rcv set p_co:-590.000000, p_co_old:-590.000000
[2026-08-08 20:29:56.203 UTC] [V] 485DevCtl <C1:04> [01][601260][-59.000000][2][kW]
[2026-08-08 20:29:56.203 UTC] [V] SummDat SetVrmValue dev_id:4 val:-590.000000 sc:3
[2026-08-08 20:29:56.203 UTC] [V] OCMgr SetMeterValue PhId:0104, branchNo:01, valueId:601260, value:-59.000000, scaleFactor:2, devId:4
[2026-08-08 20:29:56.204 UTC] [V] 485DevCtl <C1:04> [01][603260][1186433.000000][1][kWh]
[2026-08-08 20:29:56.204 UTC] [V] SummDat SetVrmValue dev_id:4 val:1186433.000000 sc:1
[2026-08-08 20:29:56.204 UTC] [V] OCMgr SetMeterValue PhId:0104, branchNo:01, valueId:603260, value:1186433.000000, scaleFactor:1, devId:4
[2026-08-08 20:29:56.204 UTC] [V] 485DevCtl <C1:04> device_type:CO-Meter
[2026-08-08 20:29:56.204 UTC] [V] OFSCtrl km50 received.
[2026-08-08 20:29:56.205 UTC] [V] OFSCtrl omron05_local_date :2026/08/09 ? 2026/08/09
[2026-08-08 20:29:56.205 UTC] [V] OFSCtrl omron05_local_time :2026/08/09 05 ? 2026/08/09 05
[2026-08-08 20:29:56.205 UTC] [V] OFSCtrl out of control time.
[2026-08-08 20:29:56.205 UTC] [V] OFSCtrl Control pv-pcs proc start.
[2026-08-08 20:29:56.219 UTC] [V] OFSCtrl NOD_month:-1664.000000 = (NOD_month:306 - ((nod_max_/30):23.333333 * (cnt-1):25) * (30/cnt):6.000000 
[2026-08-08 20:29:56.225 UTC] [V] OFSCtrl PCS ratio_month:232.646617 = -k_inhibition_ratio_month:-0.097744 * NOD_month:-1664.000000 + inhibition_ratio_max:70
[2026-08-08 20:29:56.225 UTC] [V] OFSCtrl PCS 05 inhibition_ratio:70.000000 = max(ratio_min:5, min(ratio:70, ratio_hour:70.000000, ratio_day:70.000000, ratio_month:232.646617))
[2026-08-08 20:29:56.226 UTC] [D] OFSCtrl pv-pcs ctrl val:0.000000 old:0.000000
[2026-08-08 20:29:56.226 UTC] [V] OCHisDB set rate:0 t_rate:0 cnt:58
[2026-08-08 20:29:56.226 UTC] [V] 485ChCtl <C2> pv-pcs limit on [0.000000] request.
[2026-08-08 20:29:56.226 UTC] [V] OFSCtrl Control pv-pcs proc:BATT_CHK->01->02->03->04->05->06->07->09->09->10->11->12
[2026-08-08 20:29:56.226 UTC] [V] 485ChCtl <C1> set rt:0
[2026-08-08 20:29:56.227 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:56.228 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:56.238 UTC] [V] 485DevCtl <C1:04> device_type:CO-Meter
[2026-08-08 20:29:56.309 UTC] [V] 485ChCtl <C2> pv-pcs send request.
[2026-08-08 20:29:56.310 UTC] [D] VarInf update ofs_rate:0.000000
[2026-08-08 20:29:56.310 UTC] [V] VarInf LimitSet rt[2] val[170] key[ValueOn]
[2026-08-08 20:29:56.310 UTC] [D] VarInf output_mode:8
[2026-08-08 20:29:56.310 UTC] [D] VarInf update ofs_rate:0.000000
[2026-08-08 20:29:56.310 UTC] [D] VarInf Limit setRate[0.000000] rate[0.000000] value100[1000.000000] value0[0.000000]
[2026-08-08 20:29:56.310 UTC] [V] 485DevCtl <C2:01> ChangeOutputRateToDevice rate:0.000000 set_rate1
[2026-08-08 20:29:56.310 UTC] [D] VarInf Limit rt[2] int_set_rate[1] server_rate[0.000000] rated_output[100.000000] solar_battery_power[100.000000]
[2026-08-08 20:29:56.311 UTC] [D] 485AcReq <C2:01> PutOStreamForBc [3][0d000010138e00020400aa0001466f]
[2026-08-08 20:29:56.327 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:56.327 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:56.327 UTC] [V] OFSCtrl Control charge discharge proc start.
[2026-08-08 20:29:56.328 UTC] [V] OFSCtrl CHG 20 p_th(t):-1109.900000 = p_th_old_:-1100.000000 + lev_cd_:-0.300000 * (total_pcs_capacity_:99000.000000 * cof_spec_:2.000000 / 60 * (time_threshold_renew:10.000000 * 10)), min:-1100.000000, max:119300.000000
[2026-08-08 20:29:56.328 UTC] [V] OFSCtrl CHG 21 batt_w:299.432026 = old:302.869526 +  kp:0.550000 * e:-6.250000 + ki:0.000000 * sume:9163136.950228 + kd:0.040000 * (e:-6.250000 - e1:-6.250000)
[2026-08-08 20:29:56.329 UTC] [V] OFSCtrl CHG 29 q:2.000000, mod(round):1.000000
[2026-08-08 20:29:56.330 UTC] [D] OFSCtrl battery ctrl val:0.600000
[2026-08-08 20:29:56.330 UTC] [V] 485ChCtl <C3> battery limit on [3.000000,] request.
[2026-08-08 20:29:56.330 UTC] [V] OFSCtrl Control charge discharge proc:01->02->BATT_CHK->03->04->05->06->07->10->11->20->21->22->23->24->25->27->28->29->30->31->32->33->34
[2026-08-08 20:29:56.428 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:56.428 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:56.429 UTC] [V] 485ChCtl <C3> battery send request.1
[2026-08-08 20:29:56.430 UTC] [D] VarInf Limit_Bat rt[2]set val[3] set rate[0.600000] value100[500] value-100[-500]
[2026-08-08 20:29:56.432 UTC] [D] 485AcReq <C3:01> PutOStream [6][0f000001000000090110278e0001020003]
[2026-08-08 20:29:56.493 UTC] [V] 485ChCtl <C1> StartDeviceCommunicationForOutputFluctuationSuppressionControlBroadcast 4 cnt:3605211, monitor_cnt:100, bc_elapsed:11, min:10, max:40
[2026-08-08 20:29:56.493 UTC] [V] OFSCtrl /var/local/solajithome/function/output_fluctuation_suppression/state is exist:0
[2026-08-08 20:29:56.528 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:56.528 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:56.587 UTC] [V] 485DevCtl <C3:01> AnalyzeResponseData proc restart cnt:360516 UPRstat:0
[2026-08-08 20:29:56.589 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-08 20:29:56.590 UTC] [D] 485DevCtl <C3:01> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-08 20:29:56.592 UTC] [D] 485DevCtl <C3:01> ResCnd OperationId [6] IsNormal[1] 
[2026-08-08 20:29:56.593 UTC] [V] 485ChCtl <C1> StartDeviceCommunicationForOutputFluctuationSuppressionControlBroadcast 4 cnt:3605212, monitor_cnt:101, bc_elapsed:12, min:10, max:40
[2026-08-08 20:29:56.593 UTC] [V] 485DevCtl <C1:02> Dev not PCS IsNeedToChangeOControlState
[2026-08-08 20:29:56.593 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :1
[2026-08-08 20:29:56.594 UTC] [V] 485ChCtl <C1> send request:IMT01
[2026-08-08 20:29:56.594 UTC] [D] 485AcReq <C1:02> PutOStream [1][08000204000200019039]
[2026-08-08 20:29:56.597 UTC] [V] 485DevCtl <C3:01> device_type:Battery
[2026-08-08 20:29:56.601 UTC] [V] 485ChCtl <C3> set rt:0
[2026-08-08 20:29:56.607 UTC] [V] 485ChCtl <C2> set rt:0
[2026-08-08 20:29:56.628 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:56.628 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:56.678 UTC] [V] OFSCtrl [/var/local/solajithome/function/output_fluctuation_suppression/batt_data] write success.
[2026-08-08 20:29:56.728 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:56.728 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:56.828 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:56.828 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:56.927 UTC] [V] 485DevCtl <C1:02> AnalyzeResponseData proc restart cnt:360510 UPRstat:0
[2026-08-08 20:29:56.927 UTC] [V] Res no response condition. set normal condition.
[2026-08-08 20:29:56.928 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:56.928 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:56.930 UTC] [D] 485DevCtl <C1:02> RcvDat status[2] len[7] [02040202067c52]
[2026-08-08 20:29:56.930 UTC] [D] 485DevCtl <C1:02> ResCnd OperationId [1] IsNormal[1] 
[2026-08-08 20:29:56.930 UTC] [V] 485DevCtl <C1:02> [01][431005][268.000000][1][°C]
[2026-08-08 20:29:56.931 UTC] [V] SummDat SetVrmValue dev_id:2 val:26800.000000 sc:3
[2026-08-08 20:29:56.931 UTC] [V] OCMgr SetMeterValue PhId:0102, branchNo:01, valueId:431005, value:268.000000, scaleFactor:1, devId:2
[2026-08-08 20:29:56.931 UTC] [V] 485DevCtl <C1:02> device_type:
[2026-08-08 20:29:56.932 UTC] [V] 485ChCtl <C1> set rt:0
[2026-08-08 20:29:56.993 UTC] [V] 485ChCtl <C1> StartDeviceCommunicationForOutputFluctuationSuppressionControlBroadcast 4 cnt:3605216, monitor_cnt:105, bc_elapsed:16, min:10, max:40
[2026-08-08 20:29:56.993 UTC] [V] 485DevCtl <C1:03> Dev not PCS IsNeedToChangeOControlState
[2026-08-08 20:29:56.993 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :1
[2026-08-08 20:29:56.994 UTC] [V] 485ChCtl <C1> send request:omron03
[2026-08-08 20:29:56.994 UTC] [D] 485AcReq <C1:03> PutOStream [1][08000303000000144427]
[2026-08-08 20:29:57.028 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:57.028 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:57.128 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:57.128 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:57.228 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:57.228 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:57.328 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:57.329 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:57.329 UTC] [V] OFSCtrl Control charge discharge proc start.
[2026-08-08 20:29:57.329 UTC] [V] OFSCtrl CHG 20 p_th(t):-1109.900000 = p_th_old_:-1100.000000 + lev_cd_:-0.300000 * (total_pcs_capacity_:99000.000000 * cof_spec_:2.000000 / 60 * (time_threshold_renew:10.000000 * 10)), min:-1100.000000, max:119300.000000
[2026-08-08 20:29:57.330 UTC] [V] OFSCtrl CHG 21 batt_w:295.994526 = old:299.432026 +  kp:0.550000 * e:-6.250000 + ki:0.000000 * sume:9163130.700228 + kd:0.040000 * (e:-6.250000 - e1:-6.250000)
[2026-08-08 20:29:57.330 UTC] [V] OFSCtrl CHG 29 q:2.000000, mod(round):1.000000
[2026-08-08 20:29:57.331 UTC] [D] OFSCtrl battery ctrl val:0.600000
[2026-08-08 20:29:57.331 UTC] [V] 485ChCtl <C3> battery limit on [3.000000,] request.
[2026-08-08 20:29:57.331 UTC] [V] OFSCtrl Control charge discharge proc:01->02->BATT_CHK->03->04->05->06->07->10->11->20->21->22->23->24->25->27->28->29->30->31->32->33->34
[2026-08-08 20:29:57.387 UTC] [V] 485DevCtl <C1:03> AnalyzeResponseData proc restart cnt:360510 UPRstat:0
[2026-08-08 20:29:57.388 UTC] [V] Res no response condition. set normal condition.
[2026-08-08 20:29:57.389 UTC] [D] 485DevCtl <C1:03> RcvDat status[2] len[45] [0303280000fe59000100580000ffff0000219f000025b500002cc10000005f000002570010251300002954afbb]
[2026-08-08 20:29:57.389 UTC] [D] 485DevCtl <C1:03> ResCnd OperationId [1] IsNormal[1] 
[2026-08-08 20:29:57.389 UTC] [V] 485DevCtl <C1:03> [01][301200][65113.000000][1][V]
[2026-08-08 20:29:57.390 UTC] [V] SummDat SetVrmValue dev_id:3 val:6511300.000000 sc:3
[2026-08-08 20:29:57.390 UTC] [V] OCMgr SetMeterValue PhId:0103, branchNo:01, valueId:301200, value:65113.000000, scaleFactor:1, devId:3
[2026-08-08 20:29:57.390 UTC] [V] 485DevCtl <C1:03> [01][301201][8607.000000][3][A]
[2026-08-08 20:29:57.390 UTC] [V] SummDat SetVrmValue dev_id:3 val:8607.000000 sc:3
[2026-08-08 20:29:57.391 UTC] [V] OCMgr SetMeterValue PhId:0103, branchNo:01, valueId:301201, value:8607.000000, scaleFactor:3, devId:3
[2026-08-08 20:29:57.391 UTC] [V] OFSCtrl Rcv set p_grid:105800.000000
[2026-08-08 20:29:57.391 UTC] [V] 485DevCtl <C1:03> [01][601202][10580.000000][2][kW]
[2026-08-08 20:29:57.391 UTC] [V] SummDat SetVrmValue dev_id:3 val:105800.000000 sc:3
[2026-08-08 20:29:57.392 UTC] [V] OCMgr SetMeterValue PhId:0103, branchNo:01, valueId:601202, value:10580.000000, scaleFactor:2, devId:3
[2026-08-08 20:29:57.405 UTC] [V] 485DevCtl <C1:03> device_type:Grid-Meter
[2026-08-08 20:29:57.409 UTC] [V] 485ChCtl <C2> StartDeviceCommunicationForOutputFluctuationSuppressionControlBroadcast 4 cnt:3605220, monitor_cnt:50, bc_elapsed:3605220, min:10, max:40
[2026-08-08 20:29:57.410 UTC] [V] OFSCtrl /var/local/solajithome/function/output_fluctuation_suppression/state is exist:0
[2026-08-08 20:29:57.410 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :2
[2026-08-08 20:29:57.411 UTC] [V] 485ChCtl <C2> send request:Sungrow08
[2026-08-08 20:29:57.411 UTC] [D] 485AcReq <C2:01> PutOStream [2][0800010413d80002f574]
[2026-08-08 20:29:57.415 UTC] [V] 485ChCtl <C1> set rt:0
[2026-08-08 20:29:57.428 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:57.428 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:57.429 UTC] [V] 485ChCtl <C3> battery send request.1
[2026-08-08 20:29:57.430 UTC] [D] VarInf Limit_Bat rt[2]set val[3] set rate[0.600000] value100[500] value-100[-500]
[2026-08-08 20:29:57.432 UTC] [D] 485AcReq <C3:01> PutOStream [6][0f000001000000090110278e0001020003]
[2026-08-08 20:29:57.493 UTC] [V] 485ChCtl <C1> StartDeviceCommunicationForOutputFluctuationSuppressionControlBroadcast 4 cnt:3605221, monitor_cnt:110, bc_elapsed:21, min:10, max:40
[2026-08-08 20:29:57.528 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:57.528 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:57.587 UTC] [V] 485DevCtl <C3:01> AnalyzeResponseData proc restart cnt:360517 UPRstat:0
[2026-08-08 20:29:57.590 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-08 20:29:57.591 UTC] [D] 485DevCtl <C3:01> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-08 20:29:57.591 UTC] [D] 485DevCtl <C3:01> ResCnd OperationId [6] IsNormal[1] 
[2026-08-08 20:29:57.591 UTC] [V] 485DevCtl <C3:01> device_type:Battery
[2026-08-08 20:29:57.591 UTC] [V] 485ChCtl <C3> set rt:0
[2026-08-08 20:29:57.593 UTC] [V] 485ChCtl <C1> StartDeviceCommunicationForOutputFluctuationSuppressionControlBroadcast 4 cnt:3605222, monitor_cnt:111, bc_elapsed:22, min:10, max:40
[2026-08-08 20:29:57.593 UTC] [V] 485DevCtl <C1:05> Dev not PCS IsNeedToChangeOControlState
[2026-08-08 20:29:57.593 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :1
[2026-08-08 20:29:57.594 UTC] [V] 485ChCtl <C1> send request:omron04
[2026-08-08 20:29:57.594 UTC] [D] 485AcReq <C1:05> PutOStream [1][0800050300030014b441]
[2026-08-08 20:29:57.627 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:57.628 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:57.678 UTC] [V] OFSCtrl [/var/local/solajithome/function/output_fluctuation_suppression/batt_data] write success.
[2026-08-08 20:29:57.727 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:57.728 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:57.741 UTC] [D] 485DevCtl <C2:01> RcvDat status[2] len[9] [01040400100000fa41]
[2026-08-08 20:29:57.741 UTC] [D] 485DevCtl <C2:01> ResCnd OperationId [2] IsNormal[0]  ConditionType [lggrdev:Error] Action[4]
[2026-08-08 20:29:57.742 UTC] [V] 485DevCtl <C2:01> device_type:PV-PCS
[2026-08-08 20:29:57.742 UTC] [V] 485DevCtl <C2:01> ExecuteAction name:RestartCounter value0
[2026-08-08 20:29:57.742 UTC] [V] 485DevCtl <C2:01> ExecuteAction set start cnt:0
[2026-08-08 20:29:57.742 UTC] [V] 485ChCtl <C2> set rt:0
[2026-08-08 20:29:57.809 UTC] [V] 485ChCtl <C2> StartDeviceCommunicationForOutputFluctuationSuppressionControlBroadcast 4 cnt:3605224, monitor_cnt:54, bc_elapsed:3605224, min:10, max:40
[2026-08-08 20:29:57.810 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :1
[2026-08-08 20:29:57.810 UTC] [V] 485ChCtl <C2> send request:Sungrow08
[2026-08-08 20:29:57.813 UTC] [D] 485AcReq <C2:02> PutOStream [1][08000204138a0024d54c]
[2026-08-08 20:29:57.827 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:57.828 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:57.927 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:57.928 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:57.988 UTC] [V] 485DevCtl <C1:05> AnalyzeResponseData proc restart cnt:360510 UPRstat:0
[2026-08-08 20:29:57.988 UTC] [V] Res no response condition. set normal condition.
[2026-08-08 20:29:57.990 UTC] [D] 485DevCtl <C1:05> RcvDat status[2] len[45] [0503280000209d000015b2000016caffffffda00000258ffffdf17ffffffacffffb133ffffff37001385390742]
[2026-08-08 20:29:57.990 UTC] [D] 485DevCtl <C1:05> ResCnd OperationId [1] IsNormal[1] 
[2026-08-08 20:29:57.992 UTC] [V] OFSCtrl Rcv set p_pv:-840.000000
[2026-08-08 20:29:57.992 UTC] [V] 485DevCtl <C1:05> [01][601259][-84.000000][2][kW]
[2026-08-08 20:29:57.994 UTC] [V] SummDat SetVrmValue dev_id:5 val:-840.000000 sc:3
[2026-08-08 20:29:58.001 UTC] [V] OCMgr SetMeterValue PhId:0105, branchNo:01, valueId:601259, value:-84.000000, scaleFactor:2, devId:5
[2026-08-08 20:29:58.007 UTC] [V] 485DevCtl <C1:05> [01][603259][1279289.000000][1][kWh]
[2026-08-08 20:29:58.007 UTC] [V] SummDat SetVrmValue dev_id:5 val:1279289.000000 sc:1
[2026-08-08 20:29:58.014 UTC] [V] OCMgr SetMeterValue PhId:0105, branchNo:01, valueId:603259, value:1279289.000000, scaleFactor:1, devId:5
[2026-08-08 20:29:58.019 UTC] [V] 485DevCtl <C1:05> device_type:PV-Meter
[2026-08-08 20:29:58.019 UTC] [V] 485ChCtl <C1> set rt:0
[2026-08-08 20:29:58.028 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:58.028 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:58.093 UTC] [V] 485ChCtl <C1> StartDeviceCommunicationForOutputFluctuationSuppressionControlBroadcast 4 cnt:3605227, monitor_cnt:116, bc_elapsed:27, min:10, max:40
[2026-08-08 20:29:58.093 UTC] [V] 485DevCtl <C1:06> Dev not PCS IsNeedToChangeOControlState
[2026-08-08 20:29:58.093 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :2
[2026-08-08 20:29:58.094 UTC] [V] 485ChCtl <C1> send request:omron06
[2026-08-08 20:29:58.096 UTC] [D] 485AcReq <C1:06> PutOStream [2][08000603002000084471]
[2026-08-08 20:29:58.128 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:58.128 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:58.220 UTC] [V] Res no response condition. set normal condition.
[2026-08-08 20:29:58.222 UTC] [D] 485DevCtl <C2:02> RcvDat status[2] len[77] [0204480000024a0001171f000000000000000000000000000000000000000000000000000000000000000000000000ffffffffffffffffffffffff000000000000000000000000000014008841]
[2026-08-08 20:29:58.222 UTC] [D] 485DevCtl <C2:02> ResCnd OperationId [1] IsNormal[1] 
[2026-08-08 20:29:58.222 UTC] [V] 485DevCtl <C2:02> [01][115202][0.000000][1][kWh]
[2026-08-08 20:29:58.222 UTC] [V] SummDat SetVrmValue dev_id:8 val:0.000000 sc:1
[2026-08-08 20:29:58.223 UTC] [V] OCMgr SetMeterValue PhId:0202, branchNo:01, valueId:115202, value:0.000000, scaleFactor:1, devId:8
[2026-08-08 20:29:58.223 UTC] [V] 485DevCtl <C2:02> [01][113202][66122.000000][0][kWh]
[2026-08-08 20:29:58.223 UTC] [V] SummDat SetVrmValue dev_id:8 val:66122.000000 sc:0
[2026-08-08 20:29:58.223 UTC] [V] OCMgr SetMeterValue PhId:0202, branchNo:01, valueId:113202, value:66122.000000, scaleFactor:0, devId:8
[2026-08-08 20:29:58.224 UTC] [V] 485DevCtl <C2:02> [01][121005][0.000000][1][℃]
[2026-08-08 20:29:58.224 UTC] [V] SummDat SetVrmValue dev_id:8 val:0.000000 sc:3
[2026-08-08 20:29:58.224 UTC] [V] OCMgr SetMeterValue PhId:0202, branchNo:01, valueId:121005, value:0.000000, scaleFactor:1, devId:8
[2026-08-08 20:29:58.224 UTC] [V] 485DevCtl <C2:02> [01][101100][0.000000][1][V]
[2026-08-08 20:29:58.224 UTC] [V] SummDat SetVrmValue dev_id:8 val:0.000000 sc:3
[2026-08-08 20:29:58.225 UTC] [V] OCMgr SetMeterValue PhId:0202, branchNo:01, valueId:101100, value:0.000000, scaleFactor:1, devId:8
[2026-08-08 20:29:58.225 UTC] [V] 485DevCtl <C2:02> [01][101101][0.000000][1][A]
[2026-08-08 20:29:58.225 UTC] [V] SummDat SetVrmValue dev_id:8 val:0.000000 sc:3
[2026-08-08 20:29:58.228 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:58.228 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:58.249 UTC] [V] OCMgr SetMeterValue PhId:0202, branchNo:01, valueId:101101, value:0.000000, scaleFactor:1, devId:8
[2026-08-08 20:29:58.262 UTC] [V] 485DevCtl <C2:02> [02][101100][0.000000][1][V]
[2026-08-08 20:29:58.262 UTC] [V] SummDat SetVrmValue dev_id:8 val:0.000000 sc:3
[2026-08-08 20:29:58.263 UTC] [V] OCMgr SetMeterValue PhId:0202, branchNo:02, valueId:101100, value:0.000000, scaleFactor:1, devId:8
[2026-08-08 20:29:58.265 UTC] [V] 485DevCtl <C2:02> [02][101101][0.000000][1][A]
[2026-08-08 20:29:58.266 UTC] [V] SummDat SetVrmValue dev_id:8 val:0.000000 sc:3
[2026-08-08 20:29:58.269 UTC] [V] OCMgr SetMeterValue PhId:0202, branchNo:02, valueId:101101, value:0.000000, scaleFactor:1, devId:8
[2026-08-08 20:29:58.271 UTC] [V] 485DevCtl <C2:02> [03][101100][0.000000][1][V]
[2026-08-08 20:29:58.273 UTC] [V] SummDat SetVrmValue dev_id:8 val:0.000000 sc:3
[2026-08-08 20:29:58.277 UTC] [V] OCMgr SetMeterValue PhId:0202, branchNo:03, valueId:101100, value:0.000000, scaleFactor:1, devId:8
[2026-08-08 20:29:58.284 UTC] [V] 485DevCtl <C2:02> [03][101101][0.000000][1][A]
[2026-08-08 20:29:58.287 UTC] [V] SummDat SetVrmValue dev_id:8 val:0.000000 sc:3
[2026-08-08 20:29:58.296 UTC] [V] OCMgr SetMeterValue PhId:0202, branchNo:03, valueId:101101, value:0.000000, scaleFactor:1, devId:8
[2026-08-08 20:29:58.296 UTC] [V] 485DevCtl <C2:02> [01][101102][0.000000][0][W]
[2026-08-08 20:29:58.298 UTC] [V] SummDat SetVrmValue dev_id:8 val:0.000000 sc:3
[2026-08-08 20:29:58.302 UTC] [V] OCMgr SetMeterValue PhId:0202, branchNo:01, valueId:101102, value:0.000000, scaleFactor:0, devId:8
[2026-08-08 20:29:58.310 UTC] [V] 485DevCtl <C2:02> [01][111200][0.000000][1][V]
[2026-08-08 20:29:58.318 UTC] [V] SummDat SetVrmValue dev_id:8 val:0.000000 sc:3
[2026-08-08 20:29:58.320 UTC] [V] OCMgr SetMeterValue PhId:0202, branchNo:01, valueId:111200, value:0.000000, scaleFactor:1, devId:8
[2026-08-08 20:29:58.321 UTC] [V] 485DevCtl <C2:02> [02][111200][0.000000][1][V]
[2026-08-08 20:29:58.323 UTC] [V] SummDat SetVrmValue dev_id:8 val:0.000000 sc:3
[2026-08-08 20:29:58.327 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:58.328 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:58.328 UTC] [V] OFSCtrl Control charge discharge proc start.
[2026-08-08 20:29:58.328 UTC] [V] OFSCtrl CHG 20 p_th(t):-1109.900000 = p_th_old_:-1100.000000 + lev_cd_:-0.300000 * (total_pcs_capacity_:99000.000000 * cof_spec_:2.000000 / 60 * (time_threshold_renew:10.000000 * 10)), min:-1100.000000, max:119300.000000
[2026-08-08 20:29:58.328 UTC] [V] OFSCtrl CHG 21 batt_w:292.557026 = old:295.994526 +  kp:0.550000 * e:-6.250000 + ki:0.000000 * sume:9163124.450228 + kd:0.040000 * (e:-6.250000 - e1:-6.250000)
[2026-08-08 20:29:58.329 UTC] [V] OFSCtrl CHG 29 q:2.000000, mod(round):1.000000
[2026-08-08 20:29:58.330 UTC] [D] OFSCtrl battery ctrl val:0.600000
[2026-08-08 20:29:58.330 UTC] [V] 485ChCtl <C3> battery limit on [3.000000,] request.
[2026-08-08 20:29:58.330 UTC] [V] OFSCtrl Control charge discharge proc:01->02->BATT_CHK->03->04->05->06->07->10->11->20->21->22->23->24->25->27->28->29->30->31->32->33->34
[2026-08-08 20:29:58.333 UTC] [V] OCMgr SetMeterValue PhId:0202, branchNo:02, valueId:111200, value:0.000000, scaleFactor:1, devId:8
[2026-08-08 20:29:58.339 UTC] [V] 485DevCtl <C2:02> [03][111200][0.000000][1][V]
[2026-08-08 20:29:58.340 UTC] [V] SummDat SetVrmValue dev_id:8 val:0.000000 sc:3
[2026-08-08 20:29:58.341 UTC] [V] OCMgr SetMeterValue PhId:0202, branchNo:03, valueId:111200, value:0.000000, scaleFactor:1, devId:8
[2026-08-08 20:29:58.341 UTC] [V] 485DevCtl <C2:02> [01][111201][0.000000][1][A]
[2026-08-08 20:29:58.341 UTC] [V] SummDat SetVrmValue dev_id:8 val:0.000000 sc:3
[2026-08-08 20:29:58.341 UTC] [V] OCMgr SetMeterValue PhId:0202, branchNo:01, valueId:111201, value:0.000000, scaleFactor:1, devId:8
[2026-08-08 20:29:58.342 UTC] [V] 485DevCtl <C2:02> [02][111201][0.000000][1][A]
[2026-08-08 20:29:58.342 UTC] [V] SummDat SetVrmValue dev_id:8 val:0.000000 sc:3
[2026-08-08 20:29:58.355 UTC] [V] OCMgr SetMeterValue PhId:0202, branchNo:02, valueId:111201, value:0.000000, scaleFactor:1, devId:8
[2026-08-08 20:29:58.361 UTC] [V] 485DevCtl <C2:02> [03][111201][0.000000][1][A]
[2026-08-08 20:29:58.364 UTC] [V] SummDat SetVrmValue dev_id:8 val:0.000000 sc:3
[2026-08-08 20:29:58.372 UTC] [V] OCMgr SetMeterValue PhId:0202, branchNo:03, valueId:111201, value:0.000000, scaleFactor:1, devId:8
[2026-08-08 20:29:58.372 UTC] [V] 485DevCtl <C2:02> [01][111202][0.000000][0][W]
[2026-08-08 20:29:58.372 UTC] [V] SummDat SetVrmValue dev_id:8 val:0.000000 sc:3
[2026-08-08 20:29:58.376 UTC] [V] OCMgr SetMeterValue PhId:0202, branchNo:01, valueId:111202, value:0.000000, scaleFactor:0, devId:8
[2026-08-08 20:29:58.383 UTC] [V] 485DevCtl <C2:02> [01][111203][0.000000][0][var]
[2026-08-08 20:29:58.386 UTC] [V] SummDat SetVrmValue dev_id:8 val:0.000000 sc:3
[2026-08-08 20:29:58.394 UTC] [V] OCMgr SetMeterValue PhId:0202, branchNo:01, valueId:111203, value:0.000000, scaleFactor:0, devId:8
[2026-08-08 20:29:58.397 UTC] [V] 485DevCtl <C2:02> [01][121007][0.000000][3][]
[2026-08-08 20:29:58.399 UTC] [V] SummDat SetVrmValue dev_id:8 val:0.000000 sc:3
[2026-08-08 20:29:58.407 UTC] [V] OCMgr SetMeterValue PhId:0202, branchNo:01, valueId:121007, value:0.000000, scaleFactor:3, devId:8
[2026-08-08 20:29:58.410 UTC] [V] 485DevCtl <C2:02> [01][131006][0.000000][1][Hz]
[2026-08-08 20:29:58.411 UTC] [V] SummDat SetVrmValue dev_id:8 val:0.000000 sc:3
[2026-08-08 20:29:58.417 UTC] [V] OCMgr SetMeterValue PhId:0202, branchNo:01, valueId:131006, value:0.000000, scaleFactor:1, devId:8
[2026-08-08 20:29:58.424 UTC] [V] 485DevCtl <C2:02> [01][114202][66122.000000][0][kWh]
[2026-08-08 20:29:58.425 UTC] [V] SummDat SetVrmValue dev_id:8 val:66122000.000000 sc:3
[2026-08-08 20:29:58.428 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:58.428 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:58.430 UTC] [V] 485ChCtl <C3> battery send request.1
[2026-08-08 20:29:58.430 UTC] [D] VarInf Limit_Bat rt[2]set val[3] set rate[0.600000] value100[500] value-100[-500]
[2026-08-08 20:29:58.432 UTC] [D] 485AcReq <C3:01> PutOStream [6][0f000001000000090110278e0001020003]
[2026-08-08 20:29:58.437 UTC] [V] OCMgr SetMeterValue PhId:0202, branchNo:01, valueId:114202, value:66122.000000, scaleFactor:0, devId:8
[2026-08-08 20:29:58.441 UTC] [V] 485DevCtl <C2:02> device_type:PV-PCS
[2026-08-08 20:29:58.451 UTC] [V] 485DevCtl <C2:02> set2 StatusCode[010100] DeviceName[] DeviceNumber[]
[2026-08-08 20:29:58.451 UTC] [V] 485ChCtl <C2> set rt:0
[2026-08-08 20:29:58.451 UTC] [D] 485ChCtl <C2> monitoring dev All Send
[2026-08-08 20:29:58.463 UTC] [V] 485DevCtl <C1:06> AnalyzeResponseData proc restart cnt:360510 UPRstat:0
[2026-08-08 20:29:58.463 UTC] [V] Res no response condition. set normal condition.
[2026-08-08 20:29:58.464 UTC] [D] 485DevCtl <C1:06> RcvDat status[2] len[21] [06031000000000022ee43a000000000291d3f2d400]
[2026-08-08 20:29:58.464 UTC] [D] 485DevCtl <C1:06> ResCnd OperationId [2] IsNormal[1] 
[2026-08-08 20:29:58.465 UTC] [V] StructInfo Add 36627.514000 = 0.000000+36627.514000+0.000000
[2026-08-08 20:29:58.465 UTC] [V] 485DevCtl <C1:06> [01][603238][3662751.400000][2][kWh]
[2026-08-08 20:29:58.465 UTC] [V] SummDat SetVrmValue dev_id:6 val:3662751.400000 sc:2
[2026-08-08 20:29:58.472 UTC] [V] OCMgr SetMeterValue PhId:0106, branchNo:01, valueId:603238, value:3662751.400000, scaleFactor:2, devId:6
[2026-08-08 20:29:58.489 UTC] [V] StructInfo Add 43111.410000 = 0.000000+43111.410000+0.000000
[2026-08-08 20:29:58.495 UTC] [V] 485DevCtl <C1:06> [01][613239][4311141.000000][2][kWh]
[2026-08-08 20:29:58.499 UTC] [V] SummDat SetVrmValue dev_id:6 val:4311141.000000 sc:2
[2026-08-08 20:29:58.500 UTC] [V] OCMgr SetMeterValue PhId:0106, branchNo:01, valueId:613239, value:4311141.000000, scaleFactor:2, devId:6
[2026-08-08 20:29:58.500 UTC] [V] 485DevCtl <C1:06> device_type:Batt-Meter
[2026-08-08 20:29:58.501 UTC] [V] 485ChCtl <C1> set rt:0
[2026-08-08 20:29:58.508 UTC] [D] 485ChCtl <C1> monitoring dev All Send
[2026-08-08 20:29:58.528 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:58.528 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:58.597 UTC] [V] 485DevCtl <C3:01> AnalyzeResponseData proc restart cnt:360518 UPRstat:0
[2026-08-08 20:29:58.599 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-08 20:29:58.601 UTC] [D] 485DevCtl <C3:01> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-08 20:29:58.602 UTC] [D] 485DevCtl <C3:01> ResCnd OperationId [6] IsNormal[1] 
[2026-08-08 20:29:58.602 UTC] [V] 485DevCtl <C3:01> device_type:Battery
[2026-08-08 20:29:58.604 UTC] [V] 485ChCtl <C3> set rt:0
[2026-08-08 20:29:58.627 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:58.628 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:58.679 UTC] [V] OFSCtrl [/var/local/solajithome/function/output_fluctuation_suppression/batt_data] write success.
[2026-08-08 20:29:58.727 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:58.728 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:58.827 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:58.828 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:58.927 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:58.928 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:59.027 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:59.028 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:59.127 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:59.128 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:59.228 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:59.228 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:59.328 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:59.328 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:59.328 UTC] [V] OFSCtrl Control charge discharge proc start.
[2026-08-08 20:29:59.329 UTC] [V] OFSCtrl CHG 20 p_th(t):-1109.900000 = p_th_old_:-1100.000000 + lev_cd_:-0.300000 * (total_pcs_capacity_:99000.000000 * cof_spec_:2.000000 / 60 * (time_threshold_renew:10.000000 * 10)), min:-1100.000000, max:119300.000000
[2026-08-08 20:29:59.329 UTC] [V] OFSCtrl CHG 21 batt_w:289.119526 = old:292.557026 +  kp:0.550000 * e:-6.250000 + ki:0.000000 * sume:9163118.200228 + kd:0.040000 * (e:-6.250000 - e1:-6.250000)
[2026-08-08 20:29:59.329 UTC] [V] OFSCtrl CHG 29 q:2.000000, mod(round):1.000000
[2026-08-08 20:29:59.329 UTC] [D] OFSCtrl battery ctrl val:0.600000
[2026-08-08 20:29:59.330 UTC] [V] 485ChCtl <C3> battery limit on [3.000000,] request.
[2026-08-08 20:29:59.330 UTC] [V] OFSCtrl Control charge discharge proc:01->02->BATT_CHK->03->04->05->06->07->10->11->20->21->22->23->24->25->27->28->29->30->31->32->33->34
[2026-08-08 20:29:59.428 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:59.428 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:59.429 UTC] [V] 485ChCtl <C3> battery send request.1
[2026-08-08 20:29:59.430 UTC] [D] VarInf Limit_Bat rt[2]set val[3] set rate[0.600000] value100[500] value-100[-500]
[2026-08-08 20:29:59.431 UTC] [D] 485AcReq <C3:01> PutOStream [6][0f000001000000090110278e0001020003]
[2026-08-08 20:29:59.528 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:59.528 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:59.577 UTC] [V] 485DevCtl <C3:01> AnalyzeResponseData proc restart cnt:360519 UPRstat:0
[2026-08-08 20:29:59.580 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-08 20:29:59.580 UTC] [D] 485DevCtl <C3:01> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-08 20:29:59.581 UTC] [D] 485DevCtl <C3:01> ResCnd OperationId [6] IsNormal[1] 
[2026-08-08 20:29:59.581 UTC] [V] 485DevCtl <C3:01> device_type:Battery
[2026-08-08 20:29:59.581 UTC] [V] 485ChCtl <C3> set rt:0
[2026-08-08 20:29:59.628 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:59.628 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:59.679 UTC] [V] OFSCtrl [/var/local/solajithome/function/output_fluctuation_suppression/batt_data] write success.
[2026-08-08 20:29:59.728 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:59.728 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:59.828 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:59.828 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:29:59.928 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:29:59.928 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:30:00.009 UTC] [I] SummMgr Start Summ [2026-08-08 20:30:00] snd_need[1]
[2026-08-08 20:30:00.027 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:30:00.028 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:30:00.127 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:30:00.128 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:30:00.227 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:30:00.228 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:30:00.327 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:30:00.328 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:30:00.328 UTC] [V] OFSCtrl Control charge discharge proc start.
[2026-08-08 20:30:00.328 UTC] [V] OFSCtrl CHG 20 p_th(t):-1109.900000 = p_th_old_:-1100.000000 + lev_cd_:-0.300000 * (total_pcs_capacity_:99000.000000 * cof_spec_:2.000000 / 60 * (time_threshold_renew:10.000000 * 10)), min:-1100.000000, max:119300.000000
[2026-08-08 20:30:00.329 UTC] [V] OFSCtrl CHG 21 batt_w:285.682026 = old:289.119526 +  kp:0.550000 * e:-6.250000 + ki:0.000000 * sume:9163111.950228 + kd:0.040000 * (e:-6.250000 - e1:-6.250000)
[2026-08-08 20:30:00.329 UTC] [V] OFSCtrl CHG 29 q:2.000000, mod(round):1.000000
[2026-08-08 20:30:00.329 UTC] [D] OFSCtrl battery ctrl val:0.600000
[2026-08-08 20:30:00.329 UTC] [V] 485ChCtl <C3> battery limit on [3.000000,] request.
[2026-08-08 20:30:00.329 UTC] [V] 485ChCtl <C3> battery send request.1
[2026-08-08 20:30:00.330 UTC] [D] VarInf Limit_Bat rt[2]set val[3] set rate[0.600000] value100[500] value-100[-500]
[2026-08-08 20:30:00.331 UTC] [D] 485AcReq <C3:01> PutOStream [6][0f000001000000090110278e0001020003]
[2026-08-08 20:30:00.335 UTC] [V] OFSCtrl Control charge discharge proc:01->02->BATT_CHK->03->04->05->06->07->10->11->20->21->22->23->24->25->27->28->29->30->31->32->33->34
[2026-08-08 20:30:00.393 UTC] [V] 485DevCtl <C1:01> device_type:Irr-Meter
[2026-08-08 20:30:00.393 UTC] [V] 485DevCtl <C1:01> device_type:Irr-Meter
[2026-08-08 20:30:00.393 UTC] [V] 485ChCtl <C1> fixed cycle Irr-Meter
[2026-08-08 20:30:00.393 UTC] [V] 485DevCtl <C1:01> Dev not PCS IsNeedToChangeOControlState
[2026-08-08 20:30:00.393 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :1
[2026-08-08 20:30:00.394 UTC] [V] 485ChCtl <C1> send request:Irr01
[2026-08-08 20:30:00.395 UTC] [D] 485AcReq <C1:01> PutOStream [1][080001040000000271cb]
[2026-08-08 20:30:00.407 UTC] [V] SummDB IsSummaryDataFromTime result:1 time:2026-08-08 20:25:00 db:/media/sdcard/solajithome/Database/Summary/measurement_log_20260808.db
[2026-08-08 20:30:00.427 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:30:00.427 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:30:00.487 UTC] [V] 485DevCtl <C3:01> AnalyzeResponseData proc restart cnt:360519 UPRstat:0
[2026-08-08 20:30:00.490 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-08 20:30:00.491 UTC] [D] 485DevCtl <C3:01> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-08 20:30:00.491 UTC] [D] 485DevCtl <C3:01> ResCnd OperationId [6] IsNormal[1] 
[2026-08-08 20:30:00.491 UTC] [V] 485DevCtl <C3:01> device_type:Battery
[2026-08-08 20:30:00.491 UTC] [V] 485ChCtl <C3> set rt:0
[2026-08-08 20:30:00.527 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:30:00.527 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:30:00.566 UTC] [V] SummMgr MeasurementDataParse size:94
[2026-08-08 20:30:00.599 UTC] [D] SummDat [0101] [01][401006][0.000000][2][3][1][2026-08-08 20:30:00]
[2026-08-08 20:30:00.600 UTC] [D] SummDat [0101] [01][421005][26223.333333][2][3][1][2026-08-08 20:30:00]
[2026-08-08 20:30:00.600 UTC] [D] SummDat [0102] [01][431005][26737.500000][2][3][2][2026-08-08 20:30:00]
[2026-08-08 20:30:00.600 UTC] [D] SummDat [0103] [01][604202][0.000000][2][0][3][2026-08-08 20:30:00]
[2026-08-08 20:30:00.600 UTC] [D] SummDat [0103] [01][301200][6517484.210526][2][3][3][2026-08-08 20:30:00]
[2026-08-08 20:30:00.601 UTC] [D] SummDat [0103] [01][301201][8824.894737][2][3][3][2026-08-08 20:30:00]
[2026-08-08 20:30:00.601 UTC] [D] SummDat [0103] [01][601202][108076.315789][2][3][3][2026-08-08 20:30:00]
[2026-08-08 20:30:00.601 UTC] [D] SummDat [0103] [01][603202][94309738.400000][2][2][3][2026-08-08 20:30:00]
[2026-08-08 20:30:00.601 UTC] [D] SummDat [0103] [01][613202][42706.700000][2][2][3][2026-08-08 20:30:00]
[2026-08-08 20:30:00.601 UTC] [D] SummDat [0104] [01][601260][-596.166667][2][3][4][2026-08-08 20:30:00]
[2026-08-08 20:30:00.601 UTC] [D] SummDat [0104] [01][603260][1186433.000000][2][1][4][2026-08-08 20:30:00]
[2026-08-08 20:30:00.602 UTC] [D] SummDat [0105] [01][601259][-838.333333][2][3][5][2026-08-08 20:30:00]
[2026-08-08 20:30:00.602 UTC] [D] SummDat [0105] [01][603259][1279289.000000][2][1][5][2026-08-08 20:30:00]
[2026-08-08 20:30:00.602 UTC] [D] SummDat [0106] [01][601237][275.789474][2][3][6][2026-08-08 20:30:00]
[2026-08-08 20:30:00.602 UTC] [D] SummDat [0106] [01][603238][3662751.400000][2][2][6][2026-08-08 20:30:00]
[2026-08-08 20:30:00.602 UTC] [D] SummDat [0106] [01][613239][4311141.000000][2][2][6][2026-08-08 20:30:00]
[2026-08-08 20:30:00.628 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:30:00.628 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:30:00.645 UTC] [D] SummDat [0201] [01][114202][0.000000][2][0][7][2026-08-08 20:30:00]
[2026-08-08 20:30:00.649 UTC] [D] SummDat [0201] [01][115202][0.000000][2][1][7][2026-08-08 20:30:00]
[2026-08-08 20:30:00.656 UTC] [D] SummDat [0201] [01][113202][64704.000000][2][0][7][2026-08-08 20:30:00]
[2026-08-08 20:30:00.657 UTC] [D] SummDat [0201] [01][121005][0.000000][2][3][7][2026-08-08 20:30:00]
[2026-08-08 20:30:00.657 UTC] [D] SummDat [0201] [03][111201][0.000000][2][3][7][2026-08-08 20:30:00]
[2026-08-08 20:30:00.658 UTC] [D] SummDat [0201] [02][101101][0.000000][2][3][7][2026-08-08 20:30:00]
[2026-08-08 20:30:00.658 UTC] [D] SummDat [0201] [01][111203][0.000000][2][3][7][2026-08-08 20:30:00]
[2026-08-08 20:30:00.659 UTC] [D] SummDat [0201] [01][111202][0.000000][2][3][7][2026-08-08 20:30:00]
[2026-08-08 20:30:00.661 UTC] [D] SummDat [0201] [05][101100][0.000000][2][3][7][2026-08-08 20:30:00]
[2026-08-08 20:30:00.662 UTC] [D] SummDat [0201] [01][121007][0.000000][2][3][7][2026-08-08 20:30:00]
[2026-08-08 20:30:00.665 UTC] [D] SummDat [0201] [06][101101][0.000000][2][3][7][2026-08-08 20:30:00]
[2026-08-08 20:30:00.669 UTC] [D] SummDat [0201] [01][131006][0.000000][2][3][7][2026-08-08 20:30:00]
[2026-08-08 20:30:00.679 UTC] [V] OFSCtrl [/var/local/solajithome/function/output_fluctuation_suppression/batt_data] write success.
[2026-08-08 20:30:00.677 UTC] [D] SummDat [0201] [04][101101][0.000000][2][3][7][2026-08-08 20:30:00]
[2026-08-08 20:30:00.686 UTC] [D] SummDat [0201] [06][101100][0.000000][2][3][7][2026-08-08 20:30:00]
[2026-08-08 20:30:00.687 UTC] [D] SummDat [0201] [04][101100][0.000000][2][3][7][2026-08-08 20:30:00]
[2026-08-08 20:30:00.687 UTC] [D] SummDat [0201] [03][111200][0.000000][2][3][7][2026-08-08 20:30:00]
[2026-08-08 20:30:00.687 UTC] [D] SummDat [0201] [01][111201][0.000000][2][3][7][2026-08-08 20:30:00]
[2026-08-08 20:30:00.694 UTC] [D] SummDat [0201] [02][111200][0.000000][2][3][7][2026-08-08 20:30:00]
[2026-08-08 20:30:00.696 UTC] [D] SummDat [0201] [03][101101][0.000000][2][3][7][2026-08-08 20:30:00]
[2026-08-08 20:30:00.700 UTC] [D] SummDat [0201] [01][101102][0.000000][2][3][7][2026-08-08 20:30:00]
[2026-08-08 20:30:00.702 UTC] [D] SummDat [0201] [03][101100][0.000000][2][3][7][2026-08-08 20:30:00]
[2026-08-08 20:30:00.705 UTC] [D] SummDat [0201] [01][101100][0.000000][2][3][7][2026-08-08 20:30:00]
[2026-08-08 20:30:00.706 UTC] [D] SummDat [0201] [02][111201][0.000000][2][3][7][2026-08-08 20:30:00]
[2026-08-08 20:30:00.706 UTC] [D] SummDat [0201] [05][101101][0.000000][2][3][7][2026-08-08 20:30:00]
[2026-08-08 20:30:00.706 UTC] [D] SummDat [0201] [02][101100][0.000000][2][3][7][2026-08-08 20:30:00]
[2026-08-08 20:30:00.706 UTC] [D] SummDat [0201] [01][111200][0.000000][2][3][7][2026-08-08 20:30:00]
[2026-08-08 20:30:00.706 UTC] [D] SummDat [0201] [01][101101][0.000000][2][3][7][2026-08-08 20:30:00]
[2026-08-08 20:30:00.722 UTC] [D] SummDat [0202] [01][114202][0.000000][2][0][8][2026-08-08 20:30:00]
[2026-08-08 20:30:00.722 UTC] [D] SummDat [0202] [04][101100][0.000000][2][3][8][2026-08-08 20:30:00]
[2026-08-08 20:30:00.722 UTC] [D] SummDat [0202] [04][101101][0.000000][2][3][8][2026-08-08 20:30:00]
[2026-08-08 20:30:00.728 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:30:00.728 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:30:00.729 UTC] [V] 485DevCtl <C1:01> AnalyzeResponseData proc restart cnt:360521 UPRstat:0
[2026-08-08 20:30:00.729 UTC] [V] Res no response condition. set normal condition.
[2026-08-08 20:30:00.729 UTC] [D] 485DevCtl <C1:01> RcvDat status[2] len[9] [010404000002013b24]
[2026-08-08 20:30:00.729 UTC] [D] 485DevCtl <C1:01> ResCnd OperationId [1] IsNormal[1] 
[2026-08-08 20:30:00.730 UTC] [V] OFSCtrl Rcv set flux_of_solar:0.000000
[2026-08-08 20:30:00.730 UTC] [V] 485DevCtl <C1:01> [01][401006][0.000000][1][W/m2]
[2026-08-08 20:30:00.731 UTC] [V] 485ChCtl <C3> StartDeviceCommunicationForOutputFluctuationSuppressionControlBroadcast 4 cnt:3605253, monitor_cnt:50, bc_elapsed:3605253, min:10, max:40
[2026-08-08 20:30:00.731 UTC] [V] OFSCtrl /var/local/solajithome/function/output_fluctuation_suppression/state is exist:0
[2026-08-08 20:30:00.731 UTC] [V] 485DevCtl <C3:01> Dev not PCS IsNeedToChangeOControlState
[2026-08-08 20:30:00.731 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :3
[2026-08-08 20:30:00.732 UTC] [V] 485ChCtl <C3> send request:Sungrow11
[2026-08-08 20:30:00.733 UTC] [D] 485AcReq <C3:01> PutOStream [3][0c00000100000006010435260018]
[2026-08-08 20:30:00.736 UTC] [V] SummDat SetVrmValue dev_id:1 val:0.000000 sc:3
[2026-08-08 20:30:00.736 UTC] [V] OCMgr SetMeterValue PhId:0101, branchNo:01, valueId:401006, value:0.000000, scaleFactor:1, devId:1
[2026-08-08 20:30:00.737 UTC] [V] 485DevCtl <C1:01> [01][421005][263.000000][1][℃]
[2026-08-08 20:30:00.737 UTC] [V] SummDat SetVrmValue dev_id:1 val:26300.000000 sc:3
[2026-08-08 20:30:00.737 UTC] [V] OCMgr SetMeterValue PhId:0101, branchNo:01, valueId:421005, value:263.000000, scaleFactor:1, devId:1
[2026-08-08 20:30:00.738 UTC] [V] 485DevCtl <C1:01> device_type:Irr-Meter
[2026-08-08 20:30:00.740 UTC] [V] OFSCtrl Irr-Meter received.
[2026-08-08 20:30:00.743 UTC] [D] SummDat [0202] [06][101100][0.000000][2][3][8][2026-08-08 20:30:00]
[2026-08-08 20:30:00.747 UTC] [D] SummDat [0202] [01][131006][0.000000][2][3][8][2026-08-08 20:30:00]
[2026-08-08 20:30:00.747 UTC] [D] SummDat [0202] [03][101101][0.000000][2][3][8][2026-08-08 20:30:00]
[2026-08-08 20:30:00.747 UTC] [D] SummDat [0202] [02][111200][0.000000][2][3][8][2026-08-08 20:30:00]
[2026-08-08 20:30:00.747 UTC] [D] SummDat [0202] [02][101101][0.000000][2][3][8][2026-08-08 20:30:00]
[2026-08-08 20:30:00.763 UTC] [V] 485ChCtl <C1> set rt:0
[2026-08-08 20:30:00.763 UTC] [V] 485DevCtl <C1:01> device_type:Irr-Meter
[2026-08-08 20:30:00.765 UTC] [D] SummDat [0202] [03][101100][0.000000][2][3][8][2026-08-08 20:30:00]
[2026-08-08 20:30:00.772 UTC] [D] SummDat [0202] [01][101102][0.000000][2][3][8][2026-08-08 20:30:00]
[2026-08-08 20:30:00.774 UTC] [D] SummDat [0202] [03][111200][0.000000][2][3][8][2026-08-08 20:30:00]
[2026-08-08 20:30:00.776 UTC] [D] SummDat [0202] [01][113202][66122.000000][2][0][8][2026-08-08 20:30:00]
[2026-08-08 20:30:00.778 UTC] [D] SummDat [0202] [01][111201][0.000000][2][3][8][2026-08-08 20:30:00]
[2026-08-08 20:30:00.787 UTC] [D] SummDat [0202] [03][111201][0.000000][2][3][8][2026-08-08 20:30:00]
[2026-08-08 20:30:00.787 UTC] [D] SummDat [0202] [01][111203][0.000000][2][3][8][2026-08-08 20:30:00]
[2026-08-08 20:30:00.787 UTC] [D] SummDat [0202] [01][121005][0.000000][2][3][8][2026-08-08 20:30:00]
[2026-08-08 20:30:00.787 UTC] [D] SummDat [0202] [01][111202][0.000000][2][3][8][2026-08-08 20:30:00]
[2026-08-08 20:30:00.787 UTC] [D] SummDat [0202] [05][101100][0.000000][2][3][8][2026-08-08 20:30:00]
[2026-08-08 20:30:00.793 UTC] [V] 485DevCtl <C1:04> device_type:CO-Meter
[2026-08-08 20:30:00.793 UTC] [V] 485DevCtl <C1:04> device_type:CO-Meter
[2026-08-08 20:30:00.793 UTC] [V] 485ChCtl <C1> fixed cycle CO-Meter
[2026-08-08 20:30:00.793 UTC] [V] 485DevCtl <C1:04> Dev not PCS IsNeedToChangeOControlState
[2026-08-08 20:30:00.793 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :1
[2026-08-08 20:30:00.794 UTC] [V] 485ChCtl <C1> send request:omron05
[2026-08-08 20:30:00.796 UTC] [D] 485AcReq <C1:04> PutOStream [1][0800040300030014b590]
[2026-08-08 20:30:00.804 UTC] [D] SummDat [0202] [01][121007][0.000000][2][3][8][2026-08-08 20:30:00]
[2026-08-08 20:30:00.805 UTC] [D] SummDat [0202] [02][101100][0.000000][2][3][8][2026-08-08 20:30:00]
[2026-08-08 20:30:00.805 UTC] [D] SummDat [0202] [01][111200][0.000000][2][3][8][2026-08-08 20:30:00]
[2026-08-08 20:30:00.805 UTC] [D] SummDat [0202] [01][101101][0.000000][2][3][8][2026-08-08 20:30:00]
[2026-08-08 20:30:00.805 UTC] [D] SummDat [0202] [01][115202][0.000000][2][1][8][2026-08-08 20:30:00]
[2026-08-08 20:30:00.805 UTC] [D] SummDat [0202] [06][101101][0.000000][2][3][8][2026-08-08 20:30:00]
[2026-08-08 20:30:00.822 UTC] [D] SummDat [0202] [05][101101][0.000000][2][3][8][2026-08-08 20:30:00]
[2026-08-08 20:30:00.822 UTC] [D] SummDat [0202] [02][111201][0.000000][2][3][8][2026-08-08 20:30:00]
[2026-08-08 20:30:00.822 UTC] [D] SummDat [0202] [01][101100][0.000000][2][3][8][2026-08-08 20:30:00]
[2026-08-08 20:30:00.828 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:30:00.828 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:30:00.838 UTC] [D] SummDat [0301] [01][721100][774290.000000][2][3][9][2026-08-08 20:30:00]
[2026-08-08 20:30:00.841 UTC] [D] SummDat [0301] [01][721101][0.000000][2][3][9][2026-08-08 20:30:00]
[2026-08-08 20:30:00.842 UTC] [D] SummDat [0301] [01][721035][11000.000000][2][3][9][2026-08-08 20:30:00]
[2026-08-08 20:30:00.844 UTC] [D] SummDat [0301] [01][753049][0.000000][2][0][9][2026-08-08 20:30:00]
[2026-08-08 20:30:00.847 UTC] [D] SummDat [0301] [02][753049][0.000000][2][0][9][2026-08-08 20:30:00]
[2026-08-08 20:30:00.847 UTC] [D] SummDat [0301] [01][753053][0.000000][2][0][9][2026-08-08 20:30:00]
[2026-08-08 20:30:00.847 UTC] [D] SummDat [0301] [06][753053][0.000000][2][0][9][2026-08-08 20:30:00]
[2026-08-08 20:30:00.855 UTC] [D] SummDat [0301] [01][721031][3160.600000][2][3][9][2026-08-08 20:30:00]
[2026-08-08 20:30:00.857 UTC] [V] 485DevCtl <C3:01> AnalyzeResponseData proc restart cnt:360520 UPRstat:0
[2026-08-08 20:30:00.860 UTC] [D] 485DevCtl <C3:01> RcvDat status[0] len[57] [0001000000330104301e3e0000006e03e81e3e006e00010001ffff0100ffff013b013bffff008c008c00640064ffff7e2c7b70012c011d02bb]
[2026-08-08 20:30:00.861 UTC] [D] 485DevCtl <C3:01> ResCnd OperationId [3] IsNormal[1]  ConditionType [lggrdev:Normal] Action[-1]
[2026-08-08 20:30:00.861 UTC] [V] 485DevCtl <C3:01> [01][721100][7742.000000][1][V]
[2026-08-08 20:30:00.861 UTC] [V] SummDat SetVrmValue dev_id:9 val:774200.000000 sc:3
[2026-08-08 20:30:00.862 UTC] [V] OCMgr SetMeterValue PhId:0301, branchNo:01, valueId:721100, value:7742.000000, scaleFactor:1, devId:9
[2026-08-08 20:30:00.862 UTC] [D] SummDat [0301] [02][753053][0.000000][2][0][9][2026-08-08 20:30:00]
[2026-08-08 20:30:00.863 UTC] [D] SummDat [0301] [07][753053][0.000000][2][0][9][2026-08-08 20:30:00]
[2026-08-08 20:30:00.864 UTC] [D] SummDat [0301] [01][721030][3230.700000][2][3][9][2026-08-08 20:30:00]
[2026-08-08 20:30:00.864 UTC] [V] 485DevCtl <C3:01> [01][721101][0.000000][1][A]
[2026-08-08 20:30:00.865 UTC] [V] SummDat SetVrmValue dev_id:9 val:0.000000 sc:3
[2026-08-08 20:30:00.865 UTC] [D] SummDat [0301] [03][753053][0.000000][2][0][9][2026-08-08 20:30:00]
[2026-08-08 20:30:00.866 UTC] [D] SummDat [0301] [01][703102][40439.000000][2][0][9][2026-08-08 20:30:00]
[2026-08-08 20:30:00.867 UTC] [V] OCMgr SetMeterValue PhId:0301, branchNo:01, valueId:721101, value:0.000000, scaleFactor:1, devId:9
[2026-08-08 20:30:00.867 UTC] [D] SummDat [0301] [01][716202][0.000000][2][0][9][2026-08-08 20:30:00]
[2026-08-08 20:30:00.869 UTC] [D] SummDat [0301] [01][711102][370.000000][2][3][9][2026-08-08 20:30:00]
[2026-08-08 20:30:00.871 UTC] [V] OFSCtrl change set SOC(t):11.000000 drive cnt:1
[2026-08-08 20:30:00.872 UTC] [D] SummDat [0301] [01][121005][29480.000000][2][3][9][2026-08-08 20:30:00]
[2026-08-08 20:30:00.873 UTC] [V] OFSCtrl Rcv set soc[0301]:11.000000
[2026-08-08 20:30:00.874 UTC] [D] SummDat [0301] [01][713102][37233.000000][2][0][9][2026-08-08 20:30:00]
[2026-08-08 20:30:00.874 UTC] [V] 485DevCtl <C3:01> [01][721035][110.000000][1][%]
[2026-08-08 20:30:00.876 UTC] [V] SummDat SetVrmValue dev_id:9 val:11000.000000 sc:3
[2026-08-08 20:30:00.876 UTC] [D] SummDat [0301] [04][753053][0.000000][2][0][9][2026-08-08 20:30:00]
[2026-08-08 20:30:00.878 UTC] [D] SummDat [0301] [01][753040][16.000000][2][0][9][2026-08-08 20:30:00]
[2026-08-08 20:30:00.879 UTC] [V] OCMgr SetMeterValue PhId:0301, branchNo:01, valueId:721035, value:110.000000, scaleFactor:1, devId:9
[2026-08-08 20:30:00.882 UTC] [D] SummDat [0301] [02][753040][1.000000][2][0][9][2026-08-08 20:30:00]
[2026-08-08 20:30:00.885 UTC] [V] 485DevCtl <C3:01> [01][721036][1000.000000][1][%]
[2026-08-08 20:30:00.885 UTC] [D] SummDat [0301] [01][753102][3.000000][2][1][9][2026-08-08 20:30:00]
[2026-08-08 20:30:00.887 UTC] [V] SummDat SetVrmValue dev_id:9 val:100000.000000 sc:3
[2026-08-08 20:30:00.889 UTC] [D] SummDat [0301] [05][753053][0.000000][2][0][9][2026-08-08 20:30:00]
[2026-08-08 20:30:00.893 UTC] [D] SummDat [0301] [01][721033][28500.000000][2][3][9][2026-08-08 20:30:00]
[2026-08-08 20:30:00.893 UTC] [D] SummDat [0301] [01][721032][30000.000000][2][3][9][2026-08-08 20:30:00]
[2026-08-08 20:30:00.894 UTC] [D] SummDat [0301] [01][721036][100000.000000][2][3][9][2026-08-08 20:30:00]
[2026-08-08 20:30:00.895 UTC] [V] OCMgr SetMeterValue PhId:0301, branchNo:01, valueId:721036, value:1000.000000, scaleFactor:1, devId:9
[2026-08-08 20:30:00.897 UTC] [V] 485DevCtl <C3:01> [01][721030][32300.000000][4][V]
[2026-08-08 20:30:00.899 UTC] [V] SummDat SetVrmValue dev_id:9 val:3230.000000 sc:3
[2026-08-08 20:30:00.906 UTC] [V] OCMgr SetMeterValue PhId:0301, branchNo:01, valueId:721030, value:32300.000000, scaleFactor:4, devId:9
[2026-08-08 20:30:00.909 UTC] [V] 485DevCtl <C3:01> [01][721031][31600.000000][4][V]
[2026-08-08 20:30:00.909 UTC] [V] SummDat SetVrmValue dev_id:9 val:3160.000000 sc:3
[2026-08-08 20:30:00.909 UTC] [V] OCMgr SetMeterValue PhId:0301, branchNo:01, valueId:721031, value:31600.000000, scaleFactor:4, devId:9
[2026-08-08 20:30:00.918 UTC] [V] 485DevCtl <C3:01> [01][721032][300.000000][1][℃]
[2026-08-08 20:30:00.925 UTC] [V] SummDat SetVrmValue dev_id:9 val:30000.000000 sc:3
[2026-08-08 20:30:00.925 UTC] [V] OCMgr SetMeterValue PhId:0301, branchNo:01, valueId:721032, value:300.000000, scaleFactor:1, devId:9
[2026-08-08 20:30:00.928 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:30:00.928 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:30:00.929 UTC] [V] 485DevCtl <C3:01> [01][721033][285.000000][1][℃]
[2026-08-08 20:30:00.930 UTC] [V] SummDat SetVrmValue dev_id:9 val:28500.000000 sc:3
[2026-08-08 20:30:00.932 UTC] [V] OCMgr SetMeterValue PhId:0301, branchNo:01, valueId:721033, value:285.000000, scaleFactor:1, devId:9
[2026-08-08 20:30:00.938 UTC] [V] 485DevCtl <C3:01> device_type:Battery
[2026-08-08 20:30:00.954 UTC] [V] 485ChCtl <C3> set rt:0
[2026-08-08 20:30:00.954 UTC] [D] 485ChCtl <C3> monitoring dev All Send
[2026-08-08 20:30:01.028 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:30:01.028 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:30:01.128 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:30:01.128 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:30:01.186 UTC] [V] 485DevCtl <C1:04> AnalyzeResponseData proc restart cnt:360520 UPRstat:0
[2026-08-08 20:30:01.187 UTC] [V] Res no response condition. set normal condition.
[2026-08-08 20:30:01.189 UTC] [D] 485DevCtl <C1:04> RcvDat status[2] len[45] [040328000022370000180d000017feffffffe500000258ffffe8cfffffffc5ffffaefeffffff3100121a81c001]
[2026-08-08 20:30:01.189 UTC] [D] 485DevCtl <C1:04> ResCnd OperationId [1] IsNormal[1] 
[2026-08-08 20:30:01.190 UTC] [V] OFSCtrl Rcv set p_co:-590.000000, p_co_old:-590.000000
[2026-08-08 20:30:01.190 UTC] [V] 485DevCtl <C1:04> [01][601260][-59.000000][2][kW]
[2026-08-08 20:30:01.190 UTC] [V] SummDat SetVrmValue dev_id:4 val:-590.000000 sc:3
[2026-08-08 20:30:01.199 UTC] [V] OCMgr SetMeterValue PhId:0104, branchNo:01, valueId:601260, value:-59.000000, scaleFactor:2, devId:4
[2026-08-08 20:30:01.203 UTC] [V] 485DevCtl <C1:04> [01][603260][1186433.000000][1][kWh]
[2026-08-08 20:30:01.205 UTC] [V] SummDat SetVrmValue dev_id:4 val:1186433.000000 sc:1
[2026-08-08 20:30:01.208 UTC] [V] OCMgr SetMeterValue PhId:0104, branchNo:01, valueId:603260, value:1186433.000000, scaleFactor:1, devId:4
[2026-08-08 20:30:01.209 UTC] [V] 485DevCtl <C1:04> device_type:CO-Meter
[2026-08-08 20:30:01.209 UTC] [V] OFSCtrl km50 received.
[2026-08-08 20:30:01.216 UTC] [V] OFSCtrl omron05_local_date :2026/08/09 ? 2026/08/09
[2026-08-08 20:30:01.219 UTC] [V] OFSCtrl omron05_local_time :2026/08/09 05 ? 2026/08/09 05
[2026-08-08 20:30:01.220 UTC] [V] OFSCtrl out of control time.
[2026-08-08 20:30:01.220 UTC] [V] OFSCtrl Control pv-pcs proc start.
[2026-08-08 20:30:01.228 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:30:01.228 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:30:01.228 UTC] [V] OFSCtrl NOD_month:-1664.000000 = (NOD_month:306 - ((nod_max_/30):23.333333 * (cnt-1):25) * (30/cnt):6.000000 
[2026-08-08 20:30:01.231 UTC] [V] OFSCtrl PCS ratio_month:232.646617 = -k_inhibition_ratio_month:-0.097744 * NOD_month:-1664.000000 + inhibition_ratio_max:70
[2026-08-08 20:30:01.238 UTC] [V] OFSCtrl PCS 05 inhibition_ratio:70.000000 = max(ratio_min:5, min(ratio:70, ratio_hour:70.000000, ratio_day:70.000000, ratio_month:232.646617))
[2026-08-08 20:30:01.243 UTC] [D] OFSCtrl pv-pcs ctrl val:0.000000 old:0.000000
[2026-08-08 20:30:01.243 UTC] [V] OCHisDB set rate:0 t_rate:0 cnt:59
[2026-08-08 20:30:01.243 UTC] [V] 485ChCtl <C2> pv-pcs limit on [0.000000] request.
[2026-08-08 20:30:01.243 UTC] [V] OFSCtrl Control pv-pcs proc:BATT_CHK->01->02->03->04->05->06->07->09->09->10->11->12
[2026-08-08 20:30:01.243 UTC] [V] OFSCtrl Nod calc proc start.
[2026-08-08 20:30:01.258 UTC] [V] OFSCtrl ProcNodCountCalculation culc nod skip stop:0, pause:0, ctl_time:0
[2026-08-08 20:30:01.258 UTC] [V] OFSCtrl update p_co_old:-590.000000
[2026-08-08 20:30:01.258 UTC] [V] OFSCtrl Nod calc proc:
[2026-08-08 20:30:01.259 UTC] [V] 485ChCtl <C1> set rt:0
[2026-08-08 20:30:01.259 UTC] [V] 485DevCtl <C1:04> device_type:CO-Meter
[2026-08-08 20:30:01.310 UTC] [V] 485ChCtl <C2> pv-pcs send request.
[2026-08-08 20:30:01.311 UTC] [D] VarInf update ofs_rate:0.000000
[2026-08-08 20:30:01.311 UTC] [V] VarInf LimitSet rt[2] val[170] key[ValueOn]
[2026-08-08 20:30:01.311 UTC] [D] VarInf output_mode:8
[2026-08-08 20:30:01.311 UTC] [D] VarInf update ofs_rate:0.000000
[2026-08-08 20:30:01.311 UTC] [D] VarInf Limit setRate[0.000000] rate[0.000000] value100[1000.000000] value0[0.000000]
[2026-08-08 20:30:01.311 UTC] [V] 485DevCtl <C2:01> ChangeOutputRateToDevice rate:0.000000 set_rate1
[2026-08-08 20:30:01.311 UTC] [D] VarInf Limit rt[2] int_set_rate[1] server_rate[0.000000] rated_output[100.000000] solar_battery_power[100.000000]
[2026-08-08 20:30:01.313 UTC] [D] 485AcReq <C2:01> PutOStreamForBc [3][0d000010138e00020400aa0001466f]
[2026-08-08 20:30:01.328 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:30:01.328 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:30:01.328 UTC] [V] OFSCtrl Control charge discharge proc start.
[2026-08-08 20:30:01.328 UTC] [V] OFSCtrl CHG 20 p_th(t):-1109.900000 = p_th_old_:-1100.000000 + lev_cd_:-0.300000 * (total_pcs_capacity_:99000.000000 * cof_spec_:2.000000 / 60 * (time_threshold_renew:10.000000 * 10)), min:-1100.000000, max:119300.000000
[2026-08-08 20:30:01.329 UTC] [V] OFSCtrl CHG 21 batt_w:282.244526 = old:285.682026 +  kp:0.550000 * e:-6.250000 + ki:0.000000 * sume:9163105.700228 + kd:0.040000 * (e:-6.250000 - e1:-6.250000)
[2026-08-08 20:30:01.329 UTC] [V] OFSCtrl CHG 29 q:2.000000, mod(round):1.000000
[2026-08-08 20:30:01.329 UTC] [D] OFSCtrl battery ctrl val:0.600000
[2026-08-08 20:30:01.329 UTC] [V] 485ChCtl <C3> battery limit on [3.000000,] request.
[2026-08-08 20:30:01.329 UTC] [V] OFSCtrl Control charge discharge proc:01->02->BATT_CHK->03->04->05->06->07->10->11->20->21->22->23->24->25->27->28->29->30->31->32->33->34
[2026-08-08 20:30:01.330 UTC] [V] 485ChCtl <C3> battery send request.1
[2026-08-08 20:30:01.330 UTC] [D] VarInf Limit_Bat rt[2]set val[3] set rate[0.600000] value100[500] value-100[-500]
[2026-08-08 20:30:01.332 UTC] [D] 485AcReq <C3:01> PutOStream [6][0f000001000000090110278e0001020003]
[2026-08-08 20:30:01.427 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:30:01.427 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:30:01.487 UTC] [V] 485DevCtl <C3:01> AnalyzeResponseData proc restart cnt:360520 UPRstat:0
[2026-08-08 20:30:01.490 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-08 20:30:01.490 UTC] [D] 485DevCtl <C3:01> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-08 20:30:01.491 UTC] [D] 485DevCtl <C3:01> ResCnd OperationId [6] IsNormal[1] 
[2026-08-08 20:30:01.491 UTC] [V] 485DevCtl <C3:01> device_type:Battery
[2026-08-08 20:30:01.491 UTC] [V] 485ChCtl <C3> set rt:0
[2026-08-08 20:30:01.527 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:30:01.527 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:30:01.604 UTC] [V] 485ChCtl <C2> set rt:0
[2026-08-08 20:30:01.627 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:30:01.627 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:30:01.679 UTC] [V] OFSCtrl [/var/local/solajithome/function/output_fluctuation_suppression/batt_data] write success.
[2026-08-08 20:30:01.728 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:30:01.728 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:30:01.828 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:30:01.828 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:30:01.928 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:30:01.928 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:30:02.028 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:30:02.028 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:30:02.128 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:30:02.128 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:30:02.228 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:30:02.228 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:30:02.328 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:30:02.328 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:30:02.328 UTC] [V] OFSCtrl Control charge discharge proc start.
[2026-08-08 20:30:02.328 UTC] [V] OFSCtrl CHG 20 p_th(t):-1109.900000 = p_th_old_:-1100.000000 + lev_cd_:-0.300000 * (total_pcs_capacity_:99000.000000 * cof_spec_:2.000000 / 60 * (time_threshold_renew:10.000000 * 10)), min:-1100.000000, max:119300.000000
[2026-08-08 20:30:02.329 UTC] [V] OFSCtrl CHG 21 batt_w:278.807026 = old:282.244526 +  kp:0.550000 * e:-6.250000 + ki:0.000000 * sume:9163099.450228 + kd:0.040000 * (e:-6.250000 - e1:-6.250000)
[2026-08-08 20:30:02.329 UTC] [V] OFSCtrl CHG 29 q:2.000000, mod(round):1.000000
[2026-08-08 20:30:02.329 UTC] [D] OFSCtrl battery ctrl val:0.600000
[2026-08-08 20:30:02.329 UTC] [V] 485ChCtl <C3> battery limit on [3.000000,] request.
[2026-08-08 20:30:02.329 UTC] [V] OFSCtrl Control charge discharge proc:01->02->BATT_CHK->03->04->05->06->07->10->11->20->21->22->23->24->25->27->28->29->30->31->32->33->34
[2026-08-08 20:30:02.330 UTC] [V] 485ChCtl <C3> battery send request.1
[2026-08-08 20:30:02.330 UTC] [D] VarInf Limit_Bat rt[2]set val[3] set rate[0.600000] value100[500] value-100[-500]
[2026-08-08 20:30:02.332 UTC] [D] 485AcReq <C3:01> PutOStream [6][0f000001000000090110278e0001020003]
[2026-08-08 20:30:02.427 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:30:02.427 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:30:02.487 UTC] [V] 485DevCtl <C3:01> AnalyzeResponseData proc restart cnt:360521 UPRstat:0
[2026-08-08 20:30:02.490 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-08 20:30:02.491 UTC] [D] 485DevCtl <C3:01> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-08 20:30:02.491 UTC] [D] 485DevCtl <C3:01> ResCnd OperationId [6] IsNormal[1] 
[2026-08-08 20:30:02.491 UTC] [V] 485DevCtl <C3:01> device_type:Battery
[2026-08-08 20:30:02.491 UTC] [V] 485ChCtl <C3> set rt:0
[2026-08-08 20:30:02.528 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:30:02.528 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:30:02.628 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:30:02.628 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:30:02.679 UTC] [V] OFSCtrl [/var/local/solajithome/function/output_fluctuation_suppression/batt_data] write success.
[2026-08-08 20:30:02.728 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:30:02.728 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:30:02.810 UTC] [V] 485ChCtl <C2> StartDeviceCommunicationForOutputFluctuationSuppressionControlBroadcast 4 cnt:3605274, monitor_cnt:50, bc_elapsed:3605274, min:10, max:40
[2026-08-08 20:30:02.810 UTC] [V] OFSCtrl /var/local/solajithome/function/output_fluctuation_suppression/state is exist:0
[2026-08-08 20:30:02.810 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :4
[2026-08-08 20:30:02.811 UTC] [V] 485ChCtl <C2> send request:Sungrow08
[2026-08-08 20:30:02.812 UTC] [D] 485AcReq <C2:01> PutOStream [4][0800010413b400017568]
[2026-08-08 20:30:02.828 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:30:02.828 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:30:02.928 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:30:02.928 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:30:03.028 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:30:03.028 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:30:03.128 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:30:03.128 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:30:03.147 UTC] [D] 485DevCtl <C2:01> RcvDat status[2] len[7] [0104020000b930]
[2026-08-08 20:30:03.148 UTC] [D] 485DevCtl <C2:01> ResCnd OperationId [4] IsNormal[0]  ConditionType [lggrdev:Error] Action[-1]
[2026-08-08 20:30:03.148 UTC] [V] 485DevCtl <C2:01> device_type:PV-PCS
[2026-08-08 20:30:03.149 UTC] [V] 485ChCtl <C2> set rt:0
[2026-08-08 20:30:03.210 UTC] [V] 485ChCtl <C2> StartDeviceCommunicationForOutputFluctuationSuppressionControlBroadcast 4 cnt:3605278, monitor_cnt:54, bc_elapsed:3605278, min:10, max:40
[2026-08-08 20:30:03.210 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :2
[2026-08-08 20:30:03.211 UTC] [V] 485ChCtl <C2> send request:Sungrow08
[2026-08-08 20:30:03.211 UTC] [D] 485AcReq <C2:02> PutOStream [2][0800020413d80002f547]
[2026-08-08 20:30:03.228 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:30:03.228 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:30:03.328 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:30:03.328 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:30:03.328 UTC] [V] OFSCtrl Control charge discharge proc start.
[2026-08-08 20:30:03.329 UTC] [V] OFSCtrl CHG 20 p_th(t):-1109.900000 = p_th_old_:-1100.000000 + lev_cd_:-0.300000 * (total_pcs_capacity_:99000.000000 * cof_spec_:2.000000 / 60 * (time_threshold_renew:10.000000 * 10)), min:-1100.000000, max:119300.000000
[2026-08-08 20:30:03.329 UTC] [V] OFSCtrl CHG 21 batt_w:275.369526 = old:278.807026 +  kp:0.550000 * e:-6.250000 + ki:0.000000 * sume:9163093.200228 + kd:0.040000 * (e:-6.250000 - e1:-6.250000)
[2026-08-08 20:30:03.329 UTC] [V] OFSCtrl CHG 29 q:2.000000, mod(round):1.000000
[2026-08-08 20:30:03.329 UTC] [D] OFSCtrl battery ctrl val:0.600000
[2026-08-08 20:30:03.330 UTC] [V] 485ChCtl <C3> battery send request.1
[2026-08-08 20:30:03.330 UTC] [D] VarInf Limit_Bat rt[2]set val[3] set rate[0.600000] value100[500] value-100[-500]
[2026-08-08 20:30:03.332 UTC] [D] 485AcReq <C3:01> PutOStream [6][0f000001000000090110278e0001020003]
[2026-08-08 20:30:03.335 UTC] [V] 485ChCtl <C3> battery limit on [3.000000,] request.
[2026-08-08 20:30:03.336 UTC] [V] OFSCtrl Control charge discharge proc:01->02->BATT_CHK->03->04->05->06->07->10->11->20->21->22->23->24->25->27->28->29->30->31->32->33->34
[2026-08-08 20:30:03.428 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:30:03.428 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:30:03.477 UTC] [V] 485DevCtl <C3:01> AnalyzeResponseData proc restart cnt:360522 UPRstat:0
[2026-08-08 20:30:03.480 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-08 20:30:03.481 UTC] [D] 485DevCtl <C3:01> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-08 20:30:03.481 UTC] [D] 485DevCtl <C3:01> ResCnd OperationId [6] IsNormal[1] 
[2026-08-08 20:30:03.481 UTC] [V] 485DevCtl <C3:01> device_type:Battery
[2026-08-08 20:30:03.481 UTC] [V] 485ChCtl <C3> set rt:0
[2026-08-08 20:30:03.528 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:30:03.528 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:30:03.538 UTC] [D] 485DevCtl <C2:02> RcvDat status[2] len[9] [02040400100000c941]
[2026-08-08 20:30:03.538 UTC] [D] 485DevCtl <C2:02> ResCnd OperationId [2] IsNormal[0]  ConditionType [lggrdev:Error] Action[4]
[2026-08-08 20:30:03.539 UTC] [V] 485DevCtl <C2:02> device_type:PV-PCS
[2026-08-08 20:30:03.539 UTC] [V] 485DevCtl <C2:02> ExecuteAction name:RestartCounter value0
[2026-08-08 20:30:03.539 UTC] [V] 485DevCtl <C2:02> ExecuteAction set start cnt:0
[2026-08-08 20:30:03.540 UTC] [V] 485ChCtl <C2> set rt:0
[2026-08-08 20:30:03.540 UTC] [D] 485ChCtl <C2> monitoring dev All Send
[2026-08-08 20:30:03.628 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:30:03.628 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:30:03.679 UTC] [V] OFSCtrl [/var/local/solajithome/function/output_fluctuation_suppression/batt_data] write success.
[2026-08-08 20:30:03.728 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:30:03.728 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:30:03.828 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:30:03.828 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:30:03.928 UTC] [V] OFSCtrl limit chk 400 < 800 < [1076->1076] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:30:03.928 UTC] [V] OFSCtrl angif value:1076 power_val_:-1025.000000
[2026-08-08 20:30:04.028 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:30:04.028 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:30:04.128 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:30:04.128 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:30:04.228 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:30:04.228 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:30:04.328 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:30:04.328 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:30:04.328 UTC] [V] OFSCtrl Control charge discharge proc start.
[2026-08-08 20:30:04.329 UTC] [V] OFSCtrl CHG 20 p_th(t):-1109.900000 = p_th_old_:-1100.000000 + lev_cd_:-0.300000 * (total_pcs_capacity_:99000.000000 * cof_spec_:2.000000 / 60 * (time_threshold_renew:10.000000 * 10)), min:-1100.000000, max:119300.000000
[2026-08-08 20:30:04.329 UTC] [V] OFSCtrl CHG 21 batt_w:271.932026 = old:275.369526 +  kp:0.550000 * e:-6.250000 + ki:0.000000 * sume:9163086.950228 + kd:0.040000 * (e:-6.250000 - e1:-6.250000)
[2026-08-08 20:30:04.329 UTC] [V] OFSCtrl CHG 29 q:2.000000, mod(round):1.000000
[2026-08-08 20:30:04.329 UTC] [D] OFSCtrl battery ctrl val:0.500000
[2026-08-08 20:30:04.331 UTC] [V] 485ChCtl <C3> battery limit on [3.000000,] request.
[2026-08-08 20:30:04.331 UTC] [V] OFSCtrl Control charge discharge proc:01->02->BATT_CHK->03->04->05->06->07->10->11->20->21->22->23->24->25->27->28->29->30->31->32->33->34
[2026-08-08 20:30:04.428 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:30:04.428 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:30:04.430 UTC] [V] 485ChCtl <C3> battery send request.1
[2026-08-08 20:30:04.430 UTC] [D] VarInf Limit_Bat rt[2]set val[3] set rate[0.600000] value100[500] value-100[-500]
[2026-08-08 20:30:04.432 UTC] [D] 485AcReq <C3:01> PutOStream [6][0f000001000000090110278e0001020003]
[2026-08-08 20:30:04.528 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:30:04.528 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:30:04.587 UTC] [V] 485DevCtl <C3:01> AnalyzeResponseData proc restart cnt:360524 UPRstat:0
[2026-08-08 20:30:04.590 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-08 20:30:04.591 UTC] [D] 485DevCtl <C3:01> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-08 20:30:04.591 UTC] [D] 485DevCtl <C3:01> ResCnd OperationId [6] IsNormal[1] 
[2026-08-08 20:30:04.591 UTC] [V] 485DevCtl <C3:01> device_type:Battery
[2026-08-08 20:30:04.591 UTC] [V] 485ChCtl <C3> set rt:0
[2026-08-08 20:30:04.627 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:30:04.628 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:30:04.679 UTC] [V] OFSCtrl [/var/local/solajithome/function/output_fluctuation_suppression/batt_data] write success.
[2026-08-08 20:30:04.727 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:30:04.728 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:30:04.828 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:30:04.828 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:30:04.928 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:30:04.928 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:30:05.028 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:30:05.028 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:30:05.038 UTC] [V] CIStDb UpdateStatusData. [SELECT no, on_time, off_time FROM contact_input_status WHERE no BETWEEN '1' AND '9' ORDER BY no ASC ]
[2026-08-08 20:30:05.128 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:30:05.128 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:30:05.228 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:30:05.228 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:30:05.328 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:30:05.328 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:30:05.328 UTC] [V] OFSCtrl Control charge discharge proc start.
[2026-08-08 20:30:05.329 UTC] [V] OFSCtrl CHG 20 p_th(t):-1109.900000 = p_th_old_:-1100.000000 + lev_cd_:-0.300000 * (total_pcs_capacity_:99000.000000 * cof_spec_:2.000000 / 60 * (time_threshold_renew:10.000000 * 10)), min:-1100.000000, max:119300.000000
[2026-08-08 20:30:05.329 UTC] [V] OFSCtrl CHG 21 batt_w:268.494526 = old:271.932026 +  kp:0.550000 * e:-6.250000 + ki:0.000000 * sume:9163080.700228 + kd:0.040000 * (e:-6.250000 - e1:-6.250000)
[2026-08-08 20:30:05.330 UTC] [V] OFSCtrl CHG 29 q:2.000000, mod(round):1.000000
[2026-08-08 20:30:05.331 UTC] [D] OFSCtrl battery ctrl val:0.500000
[2026-08-08 20:30:05.332 UTC] [V] 485ChCtl <C3> battery limit on [3.000000,] request.
[2026-08-08 20:30:05.332 UTC] [V] OFSCtrl Control charge discharge proc:01->02->BATT_CHK->03->04->05->06->07->10->11->20->21->22->23->24->25->27->28->29->30->31->32->33->34
[2026-08-08 20:30:05.393 UTC] [V] 485DevCtl <C1:01> device_type:Irr-Meter
[2026-08-08 20:30:05.394 UTC] [V] 485DevCtl <C1:01> device_type:Irr-Meter
[2026-08-08 20:30:05.394 UTC] [V] 485ChCtl <C1> fixed cycle Irr-Meter
[2026-08-08 20:30:05.394 UTC] [V] 485DevCtl <C1:01> Dev not PCS IsNeedToChangeOControlState
[2026-08-08 20:30:05.394 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :1
[2026-08-08 20:30:05.395 UTC] [V] 485ChCtl <C1> send request:Irr01
[2026-08-08 20:30:05.396 UTC] [D] 485AcReq <C1:01> PutOStream [1][080001040000000271cb]
[2026-08-08 20:30:05.428 UTC] [V] OFSCtrl limit chk 400 < 800 < [1075->1075] < 4000 < 4000 , cnt:0:0:601 
[2026-08-08 20:30:05.428 UTC] [V] OFSCtrl angif value:1075 power_val_:-1093.750000
[2026-08-08 20:30:05.429 UTC] [V] 485ChCtl <C3> battery send request.1