[2026-08-01 17:57:45.934 UTC] [V] 485DevCtl <C2:04> [01][101100][0.000000][1][V]
[2026-08-01 17:57:45.934 UTC] [V] SummDat SetVrmValue dev_id:10 val:0.000000 sc:3
[2026-08-01 17:57:45.947 UTC] [V] OCMgr SetMeterValue PhId:0204, branchNo:01, valueId:101100, value:0.000000, scaleFactor:1, devId:10
[2026-08-01 17:57:45.947 UTC] [V] 485DevCtl <C2:04> [01][101101][0.000000][1][A]
[2026-08-01 17:57:45.947 UTC] [V] SummDat SetVrmValue dev_id:10 val:0.000000 sc:3
[2026-08-01 17:57:45.948 UTC] [V] OCMgr SetMeterValue PhId:0204, branchNo:01, valueId:101101, value:0.000000, scaleFactor:1, devId:10
[2026-08-01 17:57:45.948 UTC] [V] 485DevCtl <C2:04> [02][101100][0.000000][1][V]
[2026-08-01 17:57:45.955 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:57:45.955 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:57:45.972 UTC] [V] SummDat SetVrmValue dev_id:10 val:0.000000 sc:3
[2026-08-01 17:57:45.974 UTC] [V] OCMgr SetMeterValue PhId:0204, branchNo:02, valueId:101100, value:0.000000, scaleFactor:1, devId:10
[2026-08-01 17:57:45.985 UTC] [V] 485DevCtl <C2:04> [02][101101][0.000000][1][A]
[2026-08-01 17:57:45.986 UTC] [V] SummDat SetVrmValue dev_id:10 val:0.000000 sc:3
[2026-08-01 17:57:45.999 UTC] [V] OCMgr SetMeterValue PhId:0204, branchNo:02, valueId:101101, value:0.000000, scaleFactor:1, devId:10
[2026-08-01 17:57:45.999 UTC] [V] 485DevCtl <C2:04> [03][101100][0.000000][1][V]
[2026-08-01 17:57:45.999 UTC] [V] SummDat SetVrmValue dev_id:10 val:0.000000 sc:3
[2026-08-01 17:57:46.000 UTC] [V] OCMgr SetMeterValue PhId:0204, branchNo:03, valueId:101100, value:0.000000, scaleFactor:1, devId:10
[2026-08-01 17:57:46.000 UTC] [V] 485DevCtl <C2:04> [03][101101][0.000000][1][A]
[2026-08-01 17:57:46.000 UTC] [V] SummDat SetVrmValue dev_id:10 val:0.000000 sc:3
[2026-08-01 17:57:46.000 UTC] [V] OCMgr SetMeterValue PhId:0204, branchNo:03, valueId:101101, value:0.000000, scaleFactor:1, devId:10
[2026-08-01 17:57:46.012 UTC] [V] OFSCtrl [/var/local/solajithome/function/output_fluctuation_suppression/batt_data] write success.
[2026-08-01 17:57:46.027 UTC] [V] 485DevCtl <C2:04> [01][101102][0.000000][0][W]
[2026-08-01 17:57:46.027 UTC] [V] SummDat SetVrmValue dev_id:10 val:0.000000 sc:3
[2026-08-01 17:57:46.027 UTC] [V] OCMgr SetMeterValue PhId:0204, branchNo:01, valueId:101102, value:0.000000, scaleFactor:0, devId:10
[2026-08-01 17:57:46.028 UTC] [V] 485DevCtl <C2:04> [01][111200][0.000000][1][V]
[2026-08-01 17:57:46.028 UTC] [V] SummDat SetVrmValue dev_id:10 val:0.000000 sc:3
[2026-08-01 17:57:46.028 UTC] [V] OCMgr SetMeterValue PhId:0204, branchNo:01, valueId:111200, value:0.000000, scaleFactor:1, devId:10
[2026-08-01 17:57:46.028 UTC] [V] 485DevCtl <C2:04> [02][111200][0.000000][1][V]
[2026-08-01 17:57:46.028 UTC] [V] SummDat SetVrmValue dev_id:10 val:0.000000 sc:3
[2026-08-01 17:57:46.029 UTC] [V] OCMgr SetMeterValue PhId:0204, branchNo:02, valueId:111200, value:0.000000, scaleFactor:1, devId:10
[2026-08-01 17:57:46.029 UTC] [V] 485DevCtl <C2:04> [03][111200][0.000000][1][V]
[2026-08-01 17:57:46.029 UTC] [V] SummDat SetVrmValue dev_id:10 val:0.000000 sc:3
[2026-08-01 17:57:46.029 UTC] [V] OCMgr SetMeterValue PhId:0204, branchNo:03, valueId:111200, value:0.000000, scaleFactor:1, devId:10
[2026-08-01 17:57:46.030 UTC] [V] 485DevCtl <C2:04> [01][111201][0.000000][1][A]
[2026-08-01 17:57:46.030 UTC] [V] SummDat SetVrmValue dev_id:10 val:0.000000 sc:3
[2026-08-01 17:57:46.030 UTC] [V] OCMgr SetMeterValue PhId:0204, branchNo:01, valueId:111201, value:0.000000, scaleFactor:1, devId:10
[2026-08-01 17:57:46.030 UTC] [V] 485DevCtl <C2:04> [02][111201][0.000000][1][A]
[2026-08-01 17:57:46.030 UTC] [V] SummDat SetVrmValue dev_id:10 val:0.000000 sc:3
[2026-08-01 17:57:46.031 UTC] [V] OCMgr SetMeterValue PhId:0204, branchNo:02, valueId:111201, value:0.000000, scaleFactor:1, devId:10
[2026-08-01 17:57:46.055 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:57:46.055 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:57:46.031 UTC] [V] 485DevCtl <C2:04> [03][111201][0.000000][1][A]
[2026-08-01 17:57:46.069 UTC] [V] SummDat SetVrmValue dev_id:10 val:0.000000 sc:3
[2026-08-01 17:57:46.078 UTC] [V] OCMgr SetMeterValue PhId:0204, branchNo:03, valueId:111201, value:0.000000, scaleFactor:1, devId:10
[2026-08-01 17:57:46.086 UTC] [V] 485DevCtl <C2:04> [01][111202][0.000000][0][W]
[2026-08-01 17:57:46.086 UTC] [V] SummDat SetVrmValue dev_id:10 val:0.000000 sc:3
[2026-08-01 17:57:46.093 UTC] [V] 485DevCtl <C1:01> AnalyzeResponseData proc restart cnt:17963 UPRstat:0
[2026-08-01 17:57:46.094 UTC] [V] Res no response condition. set normal condition.
[2026-08-01 17:57:46.096 UTC] [D] 485DevCtl <C1:01> RcvDat status[2] len[9] [010404000001fa7a57]
[2026-08-01 17:57:46.096 UTC] [D] 485DevCtl <C1:01> ResCnd OperationId [1] IsNormal[1] 
[2026-08-01 17:57:46.096 UTC] [V] OFSCtrl Rcv set flux_of_solar:0.000000
[2026-08-01 17:57:46.096 UTC] [V] 485DevCtl <C1:01> [01][401006][0.000000][1][W/m2]
[2026-08-01 17:57:46.097 UTC] [V] SummDat SetVrmValue dev_id:1 val:0.000000 sc:3
[2026-08-01 17:57:46.097 UTC] [V] OCMgr SetMeterValue PhId:0101, branchNo:01, valueId:401006, value:0.000000, scaleFactor:1, devId:1
[2026-08-01 17:57:46.097 UTC] [V] 485DevCtl <C1:01> [01][421005][256.000000][1][℃]
[2026-08-01 17:57:46.097 UTC] [V] SummDat SetVrmValue dev_id:1 val:25600.000000 sc:3
[2026-08-01 17:57:46.098 UTC] [V] OCMgr SetMeterValue PhId:0101, branchNo:01, valueId:421005, value:256.000000, scaleFactor:1, devId:1
[2026-08-01 17:57:46.098 UTC] [V] 485DevCtl <C1:01> device_type:Irr-Meter
[2026-08-01 17:57:46.098 UTC] [V] OFSCtrl Irr-Meter received.
[2026-08-01 17:57:46.098 UTC] [V] 485ChCtl <C1> set rt:0
[2026-08-01 17:57:46.100 UTC] [V] OCMgr SetMeterValue PhId:0204, branchNo:01, valueId:111202, value:0.000000, scaleFactor:0, devId:10
[2026-08-01 17:57:46.103 UTC] [V] 485DevCtl <C1:01> device_type:Irr-Meter
[2026-08-01 17:57:46.105 UTC] [V] 485DevCtl <C2:04> [01][111203][0.000000][0][var]
[2026-08-01 17:57:46.105 UTC] [V] SummDat SetVrmValue dev_id:10 val:0.000000 sc:3
[2026-08-01 17:57:46.116 UTC] [V] OCMgr SetMeterValue PhId:0204, branchNo:01, valueId:111203, value:0.000000, scaleFactor:0, devId:10
[2026-08-01 17:57:46.119 UTC] [V] 485DevCtl <C2:04> [01][121007][0.000000][3][]
[2026-08-01 17:57:46.120 UTC] [V] SummDat SetVrmValue dev_id:10 val:0.000000 sc:3
[2026-08-01 17:57:46.120 UTC] [V] OCMgr SetMeterValue PhId:0204, branchNo:01, valueId:121007, value:0.000000, scaleFactor:3, devId:10
[2026-08-01 17:57:46.120 UTC] [V] 485DevCtl <C2:04> [01][131006][0.000000][1][Hz]
[2026-08-01 17:57:46.120 UTC] [V] SummDat SetVrmValue dev_id:10 val:0.000000 sc:3
[2026-08-01 17:57:46.121 UTC] [V] OCMgr SetMeterValue PhId:0204, branchNo:01, valueId:131006, value:0.000000, scaleFactor:1, devId:10
[2026-08-01 17:57:46.130 UTC] [V] 485DevCtl <C2:04> [01][114202][50696.000000][0][kWh]
[2026-08-01 17:57:46.133 UTC] [V] SummDat SetVrmValue dev_id:10 val:50696000.000000 sc:3
[2026-08-01 17:57:46.142 UTC] [V] OCMgr SetMeterValue PhId:0204, branchNo:01, valueId:114202, value:50696.000000, scaleFactor:0, devId:10
[2026-08-01 17:57:46.143 UTC] [V] 485DevCtl <C2:04> device_type:PV-PCS
[2026-08-01 17:57:46.144 UTC] [V] 485DevCtl <C2:04> set2 StatusCode[010100] DeviceName[] DeviceNumber[]
[2026-08-01 17:57:46.153 UTC] [V] 485ChCtl <C2> set rt:0
[2026-08-01 17:57:46.155 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:57:46.155 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:57:46.156 UTC] [V] 485DevCtl <C1:04> device_type:CO-Meter
[2026-08-01 17:57:46.156 UTC] [V] 485DevCtl <C1:04> device_type:CO-Meter
[2026-08-01 17:57:46.156 UTC] [V] 485ChCtl <C1> fixed cycle CO-Meter
[2026-08-01 17:57:46.156 UTC] [V] 485DevCtl <C1:04> Dev not PCS IsNeedToChangeOControlState
[2026-08-01 17:57:46.156 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :1
[2026-08-01 17:57:46.157 UTC] [V] 485ChCtl <C1> send request:omron05
[2026-08-01 17:57:46.158 UTC] [D] 485AcReq <C1:04> PutOStream [1][0800040300030014b590]
[2026-08-01 17:57:46.165 UTC] [V] 485ChCtl <C2> StartDeviceCommunicationForOutputFluctuationSuppressionControlBroadcast 4 cnt:179404, monitor_cnt:73, bc_elapsed:179404, min:10, max:40
[2026-08-01 17:57:46.165 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :10
[2026-08-01 17:57:46.166 UTC] [V] 485ChCtl <C2> send request:Sungrow08
[2026-08-01 17:57:46.171 UTC] [D] 485AcReq <C2:05> PutOStream [10][0800050413d80002f4f0]
[2026-08-01 17:57:46.255 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:57:46.255 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:57:46.355 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:57:46.355 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:57:46.455 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:57:46.455 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:57:46.508 UTC] [V] Res no response condition. set normal condition.
[2026-08-01 17:57:46.508 UTC] [D] 485DevCtl <C2:05> RcvDat status[2] len[9] [05040400100000bf81]
[2026-08-01 17:57:46.508 UTC] [D] 485DevCtl <C2:05> ResCnd OperationId [10] IsNormal[1] 
[2026-08-01 17:57:46.509 UTC] [V] 485DevCtl <C2:05> device_type:PV-PCS
[2026-08-01 17:57:46.514 UTC] [V] 485ChCtl <C2> set rt:0
[2026-08-01 17:57:46.555 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:57:46.555 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:57:46.555 UTC] [V] OFSCtrl Control charge discharge proc start.
[2026-08-01 17:57:46.555 UTC] [V] OFSCtrl CHG 20 p_th(t):21234.450000 = p_th_old_:21224.550000 + lev_cd_:0.100000 * (total_pcs_capacity_:297000.000000 * cof_spec_:2.000000 / 60 * (time_threshold_renew:10.000000 * 10)), min:-2062.500000, max:407900.000000
[2026-08-01 17:57:46.556 UTC] [V] OFSCtrl CHG 21 batt_w:21932.225579 = old:21947.257079 +  kp:0.550000 * e:-28.050000 + ki:0.000000 * sume:-11957.549857 + kd:0.040000 * (e:-28.050000 - e1:-37.950000)
[2026-08-01 17:57:46.556 UTC] [V] OFSCtrl CHG 21 battery threshold min:20000.000000 <= bat:21932.225579 <= max:196000.000000, adjust charge:0.000000, discharge:1000.000000
[2026-08-01 17:57:46.556 UTC] [V] OFSCtrl CHG 29 q:54.000000, mod(round):3.000000
[2026-08-01 17:57:46.556 UTC] [V] OFSCtrl discharge bat_w[0303]:6500.000000 += adjust:1000.000000
[2026-08-01 17:57:46.557 UTC] [D] OFSCtrl battery ctrl val:11.000000
[2026-08-01 17:57:46.557 UTC] [V] 485ChCtl <C3> battery limit on [55.000000,55.000000,65.000000,54.000000,] request.
[2026-08-01 17:57:46.557 UTC] [V] OFSCtrl Control charge discharge proc:01->02->BATT_CHK->03->04->05->06->10->12->13->15->16->17->20->21->22->23->24->25->27->23->24->25->27->23->24->25->27->23->24->25->27->28->29->30->31->32->30->31->32->30->31->32->30->31->32->33->34
[2026-08-01 17:57:46.562 UTC] [V] 485DevCtl <C1:04> AnalyzeResponseData proc restart cnt:17963 UPRstat:0
[2026-08-01 17:57:46.562 UTC] [V] Res no response condition. set normal condition.
[2026-08-01 17:57:46.563 UTC] [D] 485DevCtl <C1:04> RcvDat status[2] len[45] [0403280000f4430000fb770000e38f0000006400000258000348b000000868ffffbea2ffffff5900233b021e71]
[2026-08-01 17:57:46.564 UTC] [D] 485DevCtl <C1:04> ResCnd OperationId [1] IsNormal[1] 
[2026-08-01 17:57:46.564 UTC] [V] 485ChCtl <C2> StartDeviceCommunicationForOutputFluctuationSuppressionControlBroadcast 4 cnt:179408, monitor_cnt:77, bc_elapsed:179408, min:10, max:40
[2026-08-01 17:57:46.564 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :9
[2026-08-01 17:57:46.565 UTC] [V] 485ChCtl <C2> send request:Sungrow08
[2026-08-01 17:57:46.566 UTC] [D] 485AcReq <C2:06> PutOStream [9][0800060413fa00179506]
[2026-08-01 17:57:46.570 UTC] [V] OFSCtrl Rcv set p_co:21520.000000, p_co_old:21460.000000
[2026-08-01 17:57:46.570 UTC] [V] 485DevCtl <C1:04> [01][601260][2152.000000][2][kW]
[2026-08-01 17:57:46.571 UTC] [V] SummDat SetVrmValue dev_id:4 val:21520.000000 sc:3
[2026-08-01 17:57:46.575 UTC] [V] OCMgr SetMeterValue PhId:0104, branchNo:01, valueId:601260, value:2152.000000, scaleFactor:2, devId:4
[2026-08-01 17:57:46.579 UTC] [V] 485ChCtl <C3> battery send request.1
[2026-08-01 17:57:46.580 UTC] [D] VarInf Limit_Bat rt[2]set val[55] set rate[11.000000] value100[500] value-100[-500]
[2026-08-01 17:57:46.581 UTC] [D] VarInf Limit_Bat rt[2]set val[55] set rate[11.000000] value100[500] value-100[-500]
[2026-08-01 17:57:46.582 UTC] [D] VarInf Limit_Bat rt[2]set val[65] set rate[13.000000] value100[500] value-100[-500]
[2026-08-01 17:57:46.583 UTC] [V] 485DevCtl <C1:04> [01][603260][2308866.000000][1][kWh]
[2026-08-01 17:57:46.586 UTC] [V] SummDat SetVrmValue dev_id:4 val:2308866.000000 sc:1
[2026-08-01 17:57:46.590 UTC] [V] OCMgr SetMeterValue PhId:0104, branchNo:01, valueId:603260, value:2308866.000000, scaleFactor:1, devId:4
[2026-08-01 17:57:46.598 UTC] [D] VarInf Limit_Bat rt[2]set val[54] set rate[10.800000] value100[500] value-100[-500]
[2026-08-01 17:57:46.599 UTC] [V] 485DevCtl <C1:04> device_type:CO-Meter
[2026-08-01 17:57:46.599 UTC] [V] OFSCtrl km50 received.
[2026-08-01 17:57:46.599 UTC] [V] OFSCtrl omron05_local_date :2026/08/02 ? 2026/08/02
[2026-08-01 17:57:46.599 UTC] [V] OFSCtrl omron05_local_time :2026/08/02 02 ? 2026/08/02 02
[2026-08-01 17:57:46.599 UTC] [V] OFSCtrl out of control time.
[2026-08-01 17:57:46.599 UTC] [V] OFSCtrl Control pv-pcs proc start.
[2026-08-01 17:57:46.600 UTC] [V] OFSCtrl NOD_month:-445.000000 = (NOD_month:13 - ((nod_max_/30):23.333333 * (cnt-1):12) * (30/cnt):1.666667 
[2026-08-01 17:57:46.600 UTC] [V] OFSCtrl PCS ratio_month:113.496241 = -k_inhibition_ratio_month:-0.097744 * NOD_month:-445.000000 + inhibition_ratio_max:70
[2026-08-01 17:57:46.600 UTC] [V] OFSCtrl PCS 05 inhibition_ratio:70.000000 = max(ratio_min:5, min(ratio:70, ratio_hour:70.000000, ratio_day:70.000000, ratio_month:113.496241))
[2026-08-01 17:57:46.600 UTC] [D] OFSCtrl pv-pcs ctrl val:0.000000 old:0.000000
[2026-08-01 17:57:46.600 UTC] [V] OCHisDB set rate:0 t_rate:0 cnt:30
[2026-08-01 17:57:46.600 UTC] [V] 485ChCtl <C2> pv-pcs limit on [0.000000] request.
[2026-08-01 17:57:46.601 UTC] [V] OFSCtrl Control pv-pcs proc:BATT_CHK->01->02->03->04->05->06->07->09->09->10->11->12
[2026-08-01 17:57:46.601 UTC] [V] OFSCtrl Nod calc proc start.
[2026-08-01 17:57:46.601 UTC] [V] OFSCtrl ProcNodCountCalculation culc nod skip stop:0, pause:0, ctl_time:0
[2026-08-01 17:57:46.601 UTC] [V] OFSCtrl update p_co_old:21520.000000
[2026-08-01 17:57:46.601 UTC] [V] OFSCtrl Nod calc proc:
[2026-08-01 17:57:46.601 UTC] [V] 485ChCtl <C1> set rt:0
[2026-08-01 17:57:46.606 UTC] [D] 485AcReq <C3:01> PutOStream [6][0f000001000000090110278e0001020037]
[2026-08-01 17:57:46.606 UTC] [D] 485AcReq <C3:02> PutOStream [6][0f000001000000090110278e0001020037]
[2026-08-01 17:57:46.607 UTC] [D] 485AcReq <C3:03> PutOStream [6][0f000001000000090110278e0001020041]
[2026-08-01 17:57:46.610 UTC] [D] 485AcReq <C3:04> PutOStream [6][0f000001000000090110278e0001020036]
[2026-08-01 17:57:46.619 UTC] [V] 485DevCtl <C1:04> device_type:CO-Meter
[2026-08-01 17:57:46.655 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:57:46.655 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:57:46.656 UTC] [V] 485ChCtl <C1> monitor no transmission period.
[2026-08-01 17:57:46.756 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:57:46.756 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:57:46.756 UTC] [V] 485ChCtl <C1> monitor no transmission period.
[2026-08-01 17:57:46.784 UTC] [V] 485DevCtl <C3:01> AnalyzeResponseData proc restart cnt:17946 UPRstat:0
[2026-08-01 17:57:46.786 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:57:46.787 UTC] [D] 485DevCtl <C3:01> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:57:46.787 UTC] [D] 485DevCtl <C3:01> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:57:46.787 UTC] [V] 485DevCtl <C3:01> device_type:Battery
[2026-08-01 17:57:46.787 UTC] [V] 485DevCtl <C3:02> AnalyzeResponseData proc restart cnt:17946 UPRstat:0
[2026-08-01 17:57:46.789 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:57:46.789 UTC] [D] 485DevCtl <C3:02> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:57:46.789 UTC] [D] 485DevCtl <C3:02> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:57:46.789 UTC] [V] 485DevCtl <C3:02> device_type:Battery
[2026-08-01 17:57:46.814 UTC] [V] 485DevCtl <C3:03> AnalyzeResponseData proc restart cnt:17946 UPRstat:0
[2026-08-01 17:57:46.837 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:57:46.844 UTC] [D] 485DevCtl <C3:03> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:57:46.845 UTC] [D] 485DevCtl <C3:03> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:57:46.848 UTC] [V] 485DevCtl <C3:03> device_type:Battery
[2026-08-01 17:57:46.855 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:57:46.856 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:57:46.857 UTC] [V] 485ChCtl <C1> StartDeviceCommunicationForOutputFluctuationSuppressionControlBroadcast 4 cnt:179411, monitor_cnt:129, bc_elapsed:11, min:10, max:40
[2026-08-01 17:57:46.856 UTC] [V] 485DevCtl <C3:04> AnalyzeResponseData proc restart cnt:17946 UPRstat:0
[2026-08-01 17:57:46.869 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:57:46.880 UTC] [D] 485DevCtl <C3:04> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:57:46.880 UTC] [D] 485DevCtl <C3:04> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:57:46.880 UTC] [V] 485DevCtl <C3:04> device_type:Battery
[2026-08-01 17:57:46.886 UTC] [V] 485ChCtl <C3> set rt:0
[2026-08-01 17:57:46.941 UTC] [V] Res no response condition. set normal condition.
[2026-08-01 17:57:46.942 UTC] [D] 485DevCtl <C2:06> RcvDat status[2] len[51] [06042e000000000000000000000000ffffffffffffffff03e8ffffffff08240000ffffffffffffffffffffffffffffffffa240]
[2026-08-01 17:57:46.942 UTC] [D] 485DevCtl <C2:06> ResCnd OperationId [9] IsNormal[1] 
[2026-08-01 17:57:46.943 UTC] [V] 485DevCtl <C2:06> [04][101100][0.000000][1][V]
[2026-08-01 17:57:46.943 UTC] [V] SummDat SetVrmValue dev_id:12 val:0.000000 sc:3
[2026-08-01 17:57:46.944 UTC] [V] OCMgr SetMeterValue PhId:0206, branchNo:04, valueId:101100, value:0.000000, scaleFactor:1, devId:12
[2026-08-01 17:57:46.953 UTC] [V] 485DevCtl <C2:06> [04][101101][0.000000][1][A]
[2026-08-01 17:57:46.955 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:57:46.955 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:57:46.956 UTC] [V] 485ChCtl <C1> StartDeviceCommunicationForOutputFluctuationSuppressionControlBroadcast 4 cnt:179412, monitor_cnt:130, bc_elapsed:12, min:10, max:40
[2026-08-01 17:57:46.956 UTC] [V] 485DevCtl <C1:05> Dev not PCS IsNeedToChangeOControlState
[2026-08-01 17:57:46.956 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :1
[2026-08-01 17:57:46.957 UTC] [V] 485ChCtl <C1> send request:omron04
[2026-08-01 17:57:46.958 UTC] [D] 485AcReq <C1:05> PutOStream [1][0800050300030014b441]
[2026-08-01 17:57:46.955 UTC] [V] SummDat SetVrmValue dev_id:12 val:0.000000 sc:3
[2026-08-01 17:57:46.966 UTC] [V] OCMgr SetMeterValue PhId:0206, branchNo:04, valueId:101101, value:0.000000, scaleFactor:1, devId:12
[2026-08-01 17:57:46.971 UTC] [V] 485DevCtl <C2:06> [05][101100][0.000000][1][V]
[2026-08-01 17:57:46.971 UTC] [V] SummDat SetVrmValue dev_id:12 val:0.000000 sc:3
[2026-08-01 17:57:46.972 UTC] [V] OCMgr SetMeterValue PhId:0206, branchNo:05, valueId:101100, value:0.000000, scaleFactor:1, devId:12
[2026-08-01 17:57:46.978 UTC] [V] 485DevCtl <C2:06> [05][101101][0.000000][1][A]
[2026-08-01 17:57:46.980 UTC] [V] SummDat SetVrmValue dev_id:12 val:0.000000 sc:3
[2026-08-01 17:57:46.987 UTC] [V] OCMgr SetMeterValue PhId:0206, branchNo:05, valueId:101101, value:0.000000, scaleFactor:1, devId:12
[2026-08-01 17:57:46.994 UTC] [V] 485DevCtl <C2:06> [06][101100][0.000000][1][V]
[2026-08-01 17:57:46.994 UTC] [V] SummDat SetVrmValue dev_id:12 val:0.000000 sc:3
[2026-08-01 17:57:46.995 UTC] [V] OCMgr SetMeterValue PhId:0206, branchNo:06, valueId:101100, value:0.000000, scaleFactor:1, devId:12
[2026-08-01 17:57:46.995 UTC] [V] 485DevCtl <C2:06> [06][101101][0.000000][1][A]
[2026-08-01 17:57:46.995 UTC] [V] SummDat SetVrmValue dev_id:12 val:0.000000 sc:3
[2026-08-01 17:57:46.995 UTC] [V] OCMgr SetMeterValue PhId:0206, branchNo:06, valueId:101101, value:0.000000, scaleFactor:1, devId:12
[2026-08-01 17:57:46.996 UTC] [V] 485DevCtl <C2:06> device_type:PV-PCS
[2026-08-01 17:57:46.997 UTC] [V] 485ChCtl <C2> set rt:0
[2026-08-01 17:57:47.013 UTC] [V] OFSCtrl [/var/local/solajithome/function/output_fluctuation_suppression/batt_data] write success.
[2026-08-01 17:57:47.018 UTC] [D] 485ChCtl <C2> monitoring dev All Send
[2026-08-01 17:57:47.055 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:57:47.055 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:57:47.064 UTC] [V] 485ChCtl <C2> pv-pcs send request.
[2026-08-01 17:57:47.064 UTC] [D] VarInf update ofs_rate:0.000000
[2026-08-01 17:57:47.064 UTC] [V] VarInf LimitSet rt[2] val[170] key[ValueOn]
[2026-08-01 17:57:47.064 UTC] [D] VarInf output_mode:8
[2026-08-01 17:57:47.065 UTC] [D] VarInf update ofs_rate:0.000000
[2026-08-01 17:57:47.065 UTC] [D] VarInf Limit setRate[0.000000] rate[0.000000] value100[1000.000000] value0[0.000000]
[2026-08-01 17:57:47.065 UTC] [V] 485DevCtl <C2:01> ChangeOutputRateToDevice rate:0.000000 set_rate1
[2026-08-01 17:57:47.065 UTC] [D] VarInf Limit rt[2] int_set_rate[1] server_rate[0.000000] rated_output[100.000000] solar_battery_power[100.000000]
[2026-08-01 17:57:47.066 UTC] [D] 485AcReq <C2:01> PutOStreamForBc [3][0d000010138e00020400aa0001466f]
[2026-08-01 17:57:47.155 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:57:47.155 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:57:47.255 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:57:47.256 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:57:47.354 UTC] [V] 485DevCtl <C1:05> AnalyzeResponseData proc restart cnt:17964 UPRstat:0
[2026-08-01 17:57:47.355 UTC] [V] Res no response condition. set normal condition.
[2026-08-01 17:57:47.356 UTC] [D] 485DevCtl <C1:05> RcvDat status[2] len[45] [050328000021f2000014140000174cffffffd900000259ffffe084ffffffb0ffffb635ffffff4400264cafb19e]
[2026-08-01 17:57:47.356 UTC] [D] 485DevCtl <C1:05> ResCnd OperationId [1] IsNormal[1] 
[2026-08-01 17:57:47.357 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:57:47.357 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:57:47.360 UTC] [V] 485ChCtl <C2> set rt:0
[2026-08-01 17:57:47.363 UTC] [V] OFSCtrl Rcv set p_pv:-800.000000
[2026-08-01 17:57:47.363 UTC] [V] 485DevCtl <C1:05> [01][601259][-80.000000][2][kW]
[2026-08-01 17:57:47.364 UTC] [V] SummDat SetVrmValue dev_id:5 val:-800.000000 sc:3
[2026-08-01 17:57:47.368 UTC] [V] OCMgr SetMeterValue PhId:0105, branchNo:01, valueId:601259, value:-80.000000, scaleFactor:2, devId:5
[2026-08-01 17:57:47.371 UTC] [V] 485DevCtl <C1:05> [01][603259][2509999.000000][1][kWh]
[2026-08-01 17:57:47.373 UTC] [V] SummDat SetVrmValue dev_id:5 val:2509999.000000 sc:1
[2026-08-01 17:57:47.377 UTC] [V] OCMgr SetMeterValue PhId:0105, branchNo:01, valueId:603259, value:2509999.000000, scaleFactor:1, devId:5
[2026-08-01 17:57:47.380 UTC] [V] 485DevCtl <C1:05> device_type:PV-Meter
[2026-08-01 17:57:47.386 UTC] [V] 485ChCtl <C1> set rt:0
[2026-08-01 17:57:47.455 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:57:47.455 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:57:47.457 UTC] [V] 485ChCtl <C1> StartDeviceCommunicationForOutputFluctuationSuppressionControlBroadcast 4 cnt:179417, monitor_cnt:135, bc_elapsed:17, min:10, max:40
[2026-08-01 17:57:47.457 UTC] [V] 485DevCtl <C1:06> Dev not PCS IsNeedToChangeOControlState
[2026-08-01 17:57:47.457 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :1
[2026-08-01 17:57:47.458 UTC] [V] 485ChCtl <C1> send request:omron06
[2026-08-01 17:57:47.459 UTC] [D] 485AcReq <C1:06> PutOStream [1][08000603000000144472]
[2026-08-01 17:57:47.462 UTC] [V] SvrSndCmdRq Rcv Msg [﻿<?xml version='1.0' encoding='UTF-8'?><commandResponse id='57'><status>SUCCESS</status></commandResponse>]
[2026-08-01 17:57:47.555 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:57:47.556 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:57:47.556 UTC] [V] OFSCtrl Control charge discharge proc start.
[2026-08-01 17:57:47.556 UTC] [V] OFSCtrl CHG 20 p_th(t):21244.350000 = p_th_old_:21234.450000 + lev_cd_:0.100000 * (total_pcs_capacity_:297000.000000 * cof_spec_:2.000000 / 60 * (time_threshold_renew:10.000000 * 10)), min:-2062.500000, max:407900.000000
[2026-08-01 17:57:47.556 UTC] [V] OFSCtrl CHG 21 batt_w:21922.639079 = old:21932.225579 +  kp:0.550000 * e:-18.150000 + ki:0.000000 * sume:-11975.699857 + kd:0.040000 * (e:-18.150000 - e1:-28.050000)
[2026-08-01 17:57:47.557 UTC] [V] OFSCtrl CHG 21 battery threshold min:20000.000000 <= bat:21922.639079 <= max:196000.000000, adjust charge:0.000000, discharge:1000.000000
[2026-08-01 17:57:47.557 UTC] [V] OFSCtrl CHG 29 q:54.000000, mod(round):3.000000
[2026-08-01 17:57:47.557 UTC] [V] OFSCtrl discharge bat_w[0303]:6500.000000 += adjust:1000.000000
[2026-08-01 17:57:47.557 UTC] [D] OFSCtrl battery ctrl val:11.000000
[2026-08-01 17:57:47.558 UTC] [V] 485ChCtl <C3> battery limit on [55.000000,55.000000,65.000000,54.000000,] request.
[2026-08-01 17:57:47.558 UTC] [V] OFSCtrl Control charge discharge proc:01->02->BATT_CHK->03->04->05->06->10->12->13->15->16->17->20->21->22->23->24->25->27->23->24->25->27->23->24->25->27->23->24->25->27->28->29->30->31->32->30->31->32->30->31->32->30->31->32->33->34
[2026-08-01 17:57:47.566 UTC] [I] SummDB UdSummDatInSent. [UPDATE measurement_log  SET sent =  1  ...]
[2026-08-01 17:57:47.578 UTC] [V] 485ChCtl <C3> battery send request.1
[2026-08-01 17:57:47.579 UTC] [D] VarInf Limit_Bat rt[2]set val[55] set rate[11.000000] value100[500] value-100[-500]
[2026-08-01 17:57:47.580 UTC] [D] VarInf Limit_Bat rt[2]set val[55] set rate[11.000000] value100[500] value-100[-500]
[2026-08-01 17:57:47.581 UTC] [D] VarInf Limit_Bat rt[2]set val[65] set rate[13.000000] value100[500] value-100[-500]
[2026-08-01 17:57:47.590 UTC] [D] VarInf Limit_Bat rt[2]set val[54] set rate[10.800000] value100[500] value-100[-500]
[2026-08-01 17:57:47.596 UTC] [D] 485AcReq <C3:01> PutOStream [6][0f000001000000090110278e0001020037]
[2026-08-01 17:57:47.597 UTC] [D] 485AcReq <C3:02> PutOStream [6][0f000001000000090110278e0001020037]
[2026-08-01 17:57:47.598 UTC] [D] 485AcReq <C3:03> PutOStream [6][0f000001000000090110278e0001020041]
[2026-08-01 17:57:47.598 UTC] [D] 485AcReq <C3:04> PutOStream [6][0f000001000000090110278e0001020036]
[2026-08-01 17:57:47.655 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:57:47.656 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:57:47.755 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:57:47.755 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:57:47.795 UTC] [V] 485DevCtl <C3:01> AnalyzeResponseData proc restart cnt:17947 UPRstat:0
[2026-08-01 17:57:47.799 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:57:47.800 UTC] [D] 485DevCtl <C3:01> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:57:47.800 UTC] [D] 485DevCtl <C3:01> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:57:47.800 UTC] [V] 485DevCtl <C3:01> device_type:Battery
[2026-08-01 17:57:47.800 UTC] [V] 485DevCtl <C3:02> AnalyzeResponseData proc restart cnt:17947 UPRstat:0
[2026-08-01 17:57:47.804 UTC] [V] SummDB UdSummDatInSent. End Update
[2026-08-01 17:57:47.805 UTC] [V] SummDB UdSummDatInSent. [UPDATE measurement_log  SET sent =  1  WHERE  ( commonId =  '010101401006'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '010101421005'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '010201431005'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '010301301200'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '010301301201'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '010301601202'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '010301603202'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '010301604202'  AND ( time BETWEEN '2026-08-01 17:45:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '010301613202'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '010401601260'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '010401603260'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '010501601259'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '010501603259'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '010601601237'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '010601603238'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '010601613239'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020101101100'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020101101101'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020101101102'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020101111200'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020101111201'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020101111202'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020101111203'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020101113202'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020101114202'  AND ( time BETWEEN '2026-08-01 17:45:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020101115202'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020101121005'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020101121007'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020101131006'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020102101100'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020102101101'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020102111200'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020102111201'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020103101100'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020103101101'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020103111200'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020103111201'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020104101100'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020104101101'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020105101100'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020105101101'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020106101100'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020106101101'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020201101100'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020201101101'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020201101102'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020201111200'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020201111201'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020201111202'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020201111203'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020201113202'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020201114202'  AND ( time BETWEEN '2026-08-01 17:45:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020201115202'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020201121005'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020201121007'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020201131006'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020202101100'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020202101101'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020202111200'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020202111201'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020203101100'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020203101101'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020203111200'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020203111201'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020204101100'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020204101101'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020205101100'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020205101101'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020206101100'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020206101101'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020301101100'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020301101101'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020301101102'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020301111200'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020301111201'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020301111202'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020301111203'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020301113202'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020301114202'  AND ( time BETWEEN '2026-08-01 17:45:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020301115202'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020301121005'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020301121007'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020301131006'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020302101100'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020302101101'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020302111200'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020302111201'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020303101100'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020303101101'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020303111200'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020303111201'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020304101100'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020304101101'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020305101100'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020305101101'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020306101100'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020306101101'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020401101100'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020401101101'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020401101102'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020401111200'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020401111201'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020401111202'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020401111203'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020401113202'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020401114202'  AND ( time BETWEEN '2026-08-01 17:45:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020401115202'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020401121005'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020401121007'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020401131006'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020402101100'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020402101101'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020402111200'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020402111201'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020403101100'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020403101101'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020403111200'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020403111201'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020404101100'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020404101101'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020405101100'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020405101101'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020406101100'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020406101101'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020501101100'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020501101101'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020501101102'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020501111200'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020501111201'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020501111202'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020501111203'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020501113202'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020501114202'  AND ( time BETWEEN '2026-08-01 17:45:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020501115202'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020501121005'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020501121007'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020501131006'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020502101100'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020502101101'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020502111200'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020502111201'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020503101100'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020503101101'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020503111200'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020503111201'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020504101100'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020504101101'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020505101100'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020505101101'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020506101100'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020506101101'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020601101100'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020601101101'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020601101102'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020601111200'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020601111201'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020601111202'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020601111203'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020601113202'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020601114202'  AND ( time BETWEEN '2026-08-01 17:45:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020601115202'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020601121005'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020601121007'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020601131006'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020602101100'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020602101101'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020602111200'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020602111201'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020603101100'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020603101101'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020603111200'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020603111201'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020604101100'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020604101101'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020605101100'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020605101101'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020606101100'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020606101101'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030101121005'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030101703102'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030101711102'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030101713102'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030101716202'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030101721030'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030101721031'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030101721032'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030101721033'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030101721035'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030101721036'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030101721100'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030101721101'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030101753040'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030101753049'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030101753053'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030101753102'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030102753040'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030102753049'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030102753053'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030103753053'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030104753053'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030105753053'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030106753053'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030107753053'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030201121005'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030201703102'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030201711102'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030201713102'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030201716202'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030201721030'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030201721031'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030201721032'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030201721033'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030201721035'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030201721036'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030201721100'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030201721101'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030201753040'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030201753049'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030201753053'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030201753102'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030202753040'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030202753049'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030202753053'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030203753053'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030204753053'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030205753053'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030206753053'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030207753053'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030301121005'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030301703102'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030301711102'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030301713102'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030301716202'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030301721030'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030301721031'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030301721032'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030301721033'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030301721035'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030301721036'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030301721100'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030301721101'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030301753040'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030301753049'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030301753053'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030301753102'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030302753040'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030302753049'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030302753053'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030303753053'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030304753053'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030305753053'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030306753053'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030307753053'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030401121005'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030401703102'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030401711102'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030401713102'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030401716202'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030401721030'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030401721031'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030401721032'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030401721033'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030401721035'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030401721036'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030401721100'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030401721101'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030401753040'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030401753049'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030401753053'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030401753102'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030402753040'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030402753049'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030402753053'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030403753053'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030404753053'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030405753053'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030406753053'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030407753053'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') );]
[2026-08-01 17:57:47.827 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:57:47.828 UTC] [D] 485DevCtl <C3:02> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:57:47.828 UTC] [D] 485DevCtl <C3:02> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:57:47.837 UTC] [V] 485DevCtl <C3:02> device_type:Battery
[2026-08-01 17:57:47.844 UTC] [V] 485DevCtl <C3:03> AnalyzeResponseData proc restart cnt:17947 UPRstat:0
[2026-08-01 17:57:47.857 UTC] [V] 485DevCtl <C1:06> AnalyzeResponseData proc restart cnt:17965 UPRstat:0
[2026-08-01 17:57:47.857 UTC] [V] Res no response condition. set normal condition.
[2026-08-01 17:57:47.860 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:57:47.862 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:57:47.862 UTC] [D] 485DevCtl <C1:06> RcvDat status[2] len[45] [0603280000080400000824000008430000fb370000f9ab0000f844000000640000025700036c57000008c3ef31]
[2026-08-01 17:57:47.862 UTC] [D] 485DevCtl <C1:06> ResCnd OperationId [1] IsNormal[1] 
[2026-08-01 17:57:47.862 UTC] [V] OFSCtrl Rcv set p_batt:22430.000000
[2026-08-01 17:57:47.863 UTC] [V] 485DevCtl <C1:06> [01][601237][2243.000000][2][kW]
[2026-08-01 17:57:47.864 UTC] [V] SummDat SetVrmValue dev_id:6 val:22430.000000 sc:3
[2026-08-01 17:57:47.864 UTC] [V] OCMgr SetMeterValue PhId:0106, branchNo:01, valueId:601237, value:2243.000000, scaleFactor:2, devId:6
[2026-08-01 17:57:47.865 UTC] [V] 485DevCtl <C1:06> device_type:Batt-Meter
[2026-08-01 17:57:47.865 UTC] [V] 485ChCtl <C1> set rt:0
[2026-08-01 17:57:47.871 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:57:47.873 UTC] [D] 485ChCtl <C1> monitoring dev All Send
[2026-08-01 17:57:47.872 UTC] [D] 485DevCtl <C3:03> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:57:47.883 UTC] [D] 485DevCtl <C3:03> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:57:47.886 UTC] [V] 485DevCtl <C3:03> device_type:Battery
[2026-08-01 17:57:47.895 UTC] [V] 485DevCtl <C3:04> AnalyzeResponseData proc restart cnt:17947 UPRstat:0
[2026-08-01 17:57:47.908 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:57:47.922 UTC] [D] 485DevCtl <C3:04> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:57:47.922 UTC] [D] 485DevCtl <C3:04> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:57:47.922 UTC] [V] 485DevCtl <C3:04> device_type:Battery
[2026-08-01 17:57:47.923 UTC] [V] 485ChCtl <C3> set rt:0
[2026-08-01 17:57:47.956 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:57:47.956 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:57:48.012 UTC] [V] OFSCtrl [/var/local/solajithome/function/output_fluctuation_suppression/batt_data] write success.
[2026-08-01 17:57:48.055 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:57:48.055 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:57:48.155 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:57:48.155 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:57:48.255 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:57:48.255 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:57:48.355 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:57:48.355 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:57:48.455 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:57:48.455 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:57:48.555 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:57:48.556 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:57:48.556 UTC] [V] OFSCtrl Control charge discharge proc start.
[2026-08-01 17:57:48.556 UTC] [V] OFSCtrl CHG 20 p_th(t):21254.250000 = p_th_old_:21244.350000 + lev_cd_:0.100000 * (total_pcs_capacity_:297000.000000 * cof_spec_:2.000000 / 60 * (time_threshold_renew:10.000000 * 10)), min:-2062.500000, max:407900.000000
[2026-08-01 17:57:48.556 UTC] [V] OFSCtrl CHG 21 batt_w:21918.497579 = old:21922.639079 +  kp:0.550000 * e:-8.250000 + ki:0.000000 * sume:-11983.949857 + kd:0.040000 * (e:-8.250000 - e1:-18.150000)
[2026-08-01 17:57:48.558 UTC] [V] OFSCtrl CHG 21 battery threshold min:20000.000000 <= bat:21918.497579 <= max:196000.000000, adjust charge:0.000000, discharge:1000.000000
[2026-08-01 17:57:48.559 UTC] [V] OFSCtrl CHG 29 q:54.000000, mod(round):3.000000
[2026-08-01 17:57:48.560 UTC] [V] OFSCtrl discharge bat_w[0303]:6500.000000 += adjust:1000.000000
[2026-08-01 17:57:48.560 UTC] [D] OFSCtrl battery ctrl val:11.000000
[2026-08-01 17:57:48.570 UTC] [V] 485ChCtl <C3> battery limit on [55.000000,55.000000,65.000000,54.000000,] request.
[2026-08-01 17:57:48.574 UTC] [V] OFSCtrl Control charge discharge proc:01->02->BATT_CHK->03->04->05->06->10->12->13->15->16->17->20->21->22->23->24->25->27->23->24->25->27->23->24->25->27->23->24->25->27->28->29->30->31->32->30->31->32->30->31->32->30->31->32->33->34
[2026-08-01 17:57:48.578 UTC] [V] 485ChCtl <C3> battery send request.1
[2026-08-01 17:57:48.579 UTC] [D] VarInf Limit_Bat rt[2]set val[55] set rate[11.000000] value100[500] value-100[-500]
[2026-08-01 17:57:48.580 UTC] [D] VarInf Limit_Bat rt[2]set val[55] set rate[11.000000] value100[500] value-100[-500]
[2026-08-01 17:57:48.581 UTC] [D] VarInf Limit_Bat rt[2]set val[65] set rate[13.000000] value100[500] value-100[-500]
[2026-08-01 17:57:48.582 UTC] [D] VarInf Limit_Bat rt[2]set val[54] set rate[10.800000] value100[500] value-100[-500]
[2026-08-01 17:57:48.598 UTC] [D] 485AcReq <C3:01> PutOStream [6][0f000001000000090110278e0001020037]
[2026-08-01 17:57:48.598 UTC] [D] 485AcReq <C3:02> PutOStream [6][0f000001000000090110278e0001020037]
[2026-08-01 17:57:48.599 UTC] [D] 485AcReq <C3:03> PutOStream [6][0f000001000000090110278e0001020041]
[2026-08-01 17:57:48.600 UTC] [D] 485AcReq <C3:04> PutOStream [6][0f000001000000090110278e0001020036]
[2026-08-01 17:57:48.655 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:57:48.655 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:57:48.755 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:57:48.755 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:57:48.774 UTC] [V] 485DevCtl <C3:01> AnalyzeResponseData proc restart cnt:17948 UPRstat:0
[2026-08-01 17:57:48.778 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:57:48.779 UTC] [D] 485DevCtl <C3:01> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:57:48.782 UTC] [D] 485DevCtl <C3:01> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:57:48.783 UTC] [V] 485DevCtl <C3:01> device_type:Battery
[2026-08-01 17:57:48.789 UTC] [V] 485DevCtl <C3:02> AnalyzeResponseData proc restart cnt:17948 UPRstat:0
[2026-08-01 17:57:48.810 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:57:48.815 UTC] [D] 485DevCtl <C3:02> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:57:48.815 UTC] [D] 485DevCtl <C3:02> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:57:48.815 UTC] [V] 485DevCtl <C3:02> device_type:Battery
[2026-08-01 17:57:48.816 UTC] [V] 485DevCtl <C3:03> AnalyzeResponseData proc restart cnt:17948 UPRstat:0
[2026-08-01 17:57:48.817 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:57:48.828 UTC] [D] 485DevCtl <C3:03> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:57:48.829 UTC] [D] 485DevCtl <C3:03> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:57:48.829 UTC] [V] 485DevCtl <C3:03> device_type:Battery
[2026-08-01 17:57:48.832 UTC] [V] 485DevCtl <C3:04> AnalyzeResponseData proc restart cnt:17948 UPRstat:0
[2026-08-01 17:57:48.851 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:57:48.855 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:57:48.856 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:57:48.860 UTC] [D] 485DevCtl <C3:04> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:57:48.861 UTC] [D] 485DevCtl <C3:04> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:57:48.863 UTC] [V] 485DevCtl <C3:04> device_type:Battery
[2026-08-01 17:57:48.866 UTC] [V] 485ChCtl <C3> set rt:0
[2026-08-01 17:57:48.955 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:57:48.955 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:57:49.012 UTC] [V] OFSCtrl [/var/local/solajithome/function/output_fluctuation_suppression/batt_data] write success.
[2026-08-01 17:57:49.055 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:57:49.055 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:57:49.151 UTC] [I] SummDB UdSummDatInSent. [UPDATE measurement_log  SET sent =  1  ...]
[2026-08-01 17:57:49.155 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:57:49.155 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:57:49.255 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:57:49.255 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:57:49.345 UTC] [V] SummDB UdSummDatInSent. End Update
[2026-08-01 17:57:49.345 UTC] [V] SummDB UdSummDatInSent. [UPDATE measurement_log  SET sent =  1  WHERE  ( commonId =  '010101401006'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '010101421005'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '010201431005'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '010301301200'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '010301301201'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '010301601202'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '010301603202'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '010301604202'  AND ( time BETWEEN '2026-08-01 17:45:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '010301613202'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '010401601260'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '010401603260'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '010501601259'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '010501603259'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '010601601237'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '010601603238'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '010601613239'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020101101100'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020101101101'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020101101102'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020101111200'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020101111201'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020101111202'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020101111203'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020101113202'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020101114202'  AND ( time BETWEEN '2026-08-01 17:45:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020101115202'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020101121005'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020101121007'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020101131006'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020102101100'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020102101101'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020102111200'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020102111201'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020103101100'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020103101101'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020103111200'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020103111201'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020104101100'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020104101101'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020105101100'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020105101101'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020106101100'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020106101101'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020201101100'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020201101101'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020201101102'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020201111200'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020201111201'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020201111202'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020201111203'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020201113202'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020201114202'  AND ( time BETWEEN '2026-08-01 17:45:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020201115202'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020201121005'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020201121007'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020201131006'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020202101100'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020202101101'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020202111200'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020202111201'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020203101100'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020203101101'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020203111200'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020203111201'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020204101100'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020204101101'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020205101100'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020205101101'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020206101100'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020206101101'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020301101100'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020301101101'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020301101102'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020301111200'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020301111201'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020301111202'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020301111203'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020301113202'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020301114202'  AND ( time BETWEEN '2026-08-01 17:45:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020301115202'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020301121005'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020301121007'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020301131006'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020302101100'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020302101101'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020302111200'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020302111201'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020303101100'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020303101101'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020303111200'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020303111201'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020304101100'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020304101101'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020305101100'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020305101101'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020306101100'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020306101101'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020401101100'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020401101101'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020401101102'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020401111200'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020401111201'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020401111202'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020401111203'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020401113202'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020401114202'  AND ( time BETWEEN '2026-08-01 17:45:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020401115202'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020401121005'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020401121007'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020401131006'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020402101100'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020402101101'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020402111200'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020402111201'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020403101100'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020403101101'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020403111200'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020403111201'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020404101100'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020404101101'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020405101100'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020405101101'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020406101100'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020406101101'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020501101100'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020501101101'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020501101102'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020501111200'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020501111201'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020501111202'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020501111203'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020501113202'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020501114202'  AND ( time BETWEEN '2026-08-01 17:45:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020501115202'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020501121005'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020501121007'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020501131006'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020502101100'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020502101101'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020502111200'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020502111201'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020503101100'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020503101101'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020503111200'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020503111201'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020504101100'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020504101101'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020505101100'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020505101101'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020506101100'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020506101101'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020601101100'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020601101101'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020601101102'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020601111200'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020601111201'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020601111202'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020601111203'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020601113202'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020601114202'  AND ( time BETWEEN '2026-08-01 17:45:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020601115202'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020601121005'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020601121007'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020601131006'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020602101100'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020602101101'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020602111200'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020602111201'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020603101100'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020603101101'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020603111200'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020603111201'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020604101100'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020604101101'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020605101100'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020605101101'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020606101100'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '020606101101'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030101121005'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030101703102'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030101711102'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030101713102'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030101716202'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030101721030'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030101721031'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030101721032'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030101721033'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030101721035'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030101721036'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030101721100'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030101721101'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030101753040'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030101753049'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030101753053'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030101753102'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030102753040'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030102753049'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030102753053'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030103753053'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030104753053'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030105753053'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030106753053'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030107753053'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030201121005'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030201703102'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030201711102'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030201713102'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030201716202'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030201721030'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030201721031'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030201721032'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030201721033'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030201721035'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030201721036'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030201721100'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030201721101'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030201753040'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030201753049'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030201753053'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030201753102'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030202753040'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030202753049'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030202753053'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030203753053'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030204753053'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030205753053'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030206753053'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030207753053'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030301121005'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030301703102'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030301711102'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030301713102'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030301716202'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030301721030'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030301721031'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030301721032'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030301721033'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030301721035'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030301721036'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030301721100'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030301721101'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030301753040'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030301753049'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030301753053'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030301753102'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030302753040'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030302753049'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030302753053'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030303753053'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030304753053'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030305753053'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030306753053'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030307753053'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030401121005'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030401703102'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030401711102'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030401713102'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030401716202'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030401721030'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030401721031'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030401721032'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030401721033'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030401721035'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030401721036'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030401721100'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030401721101'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030401753040'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030401753049'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030401753053'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030401753102'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030402753040'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030402753049'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030402753053'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030403753053'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030404753053'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030405753053'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030406753053'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') ) OR  ( commonId =  '030407753053'  AND ( time BETWEEN '2026-08-01 17:50:00' AND '2026-08-01 17:55:00 ') );]
[2026-08-01 17:57:49.355 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:57:49.355 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:57:49.455 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:57:49.456 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:57:49.555 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:57:49.555 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:57:49.555 UTC] [V] OFSCtrl Control charge discharge proc start.
[2026-08-01 17:57:49.556 UTC] [V] OFSCtrl CHG 20 p_th(t):21264.150000 = p_th_old_:21254.250000 + lev_cd_:0.100000 * (total_pcs_capacity_:297000.000000 * cof_spec_:2.000000 / 60 * (time_threshold_renew:10.000000 * 10)), min:-2062.500000, max:407900.000000
[2026-08-01 17:57:49.556 UTC] [V] OFSCtrl CHG 21 batt_w:21919.801079 = old:21918.497579 +  kp:0.550000 * e:1.650000 + ki:0.000000 * sume:-11982.299857 + kd:0.040000 * (e:1.650000 - e1:-8.250000)
[2026-08-01 17:57:49.557 UTC] [V] OFSCtrl CHG 21 battery threshold min:20000.000000 <= bat:21919.801079 <= max:196000.000000, adjust charge:0.000000, discharge:1000.000000
[2026-08-01 17:57:49.557 UTC] [V] OFSCtrl CHG 29 q:54.000000, mod(round):3.000000
[2026-08-01 17:57:49.557 UTC] [V] OFSCtrl discharge bat_w[0303]:6500.000000 += adjust:1000.000000
[2026-08-01 17:57:49.557 UTC] [D] OFSCtrl battery ctrl val:11.000000
[2026-08-01 17:57:49.558 UTC] [V] 485ChCtl <C3> battery limit on [55.000000,55.000000,65.000000,54.000000,] request.
[2026-08-01 17:57:49.558 UTC] [V] OFSCtrl Control charge discharge proc:01->02->BATT_CHK->03->04->05->06->10->12->13->15->16->17->20->21->22->23->24->25->27->23->24->25->27->23->24->25->27->23->24->25->27->28->29->30->31->32->30->31->32->30->31->32->30->31->32->33->34
[2026-08-01 17:57:49.578 UTC] [V] 485ChCtl <C3> battery send request.1
[2026-08-01 17:57:49.579 UTC] [D] VarInf Limit_Bat rt[2]set val[55] set rate[11.000000] value100[500] value-100[-500]
[2026-08-01 17:57:49.581 UTC] [D] VarInf Limit_Bat rt[2]set val[55] set rate[11.000000] value100[500] value-100[-500]
[2026-08-01 17:57:49.587 UTC] [D] VarInf Limit_Bat rt[2]set val[65] set rate[13.000000] value100[500] value-100[-500]
[2026-08-01 17:57:49.598 UTC] [D] VarInf Limit_Bat rt[2]set val[54] set rate[10.800000] value100[500] value-100[-500]
[2026-08-01 17:57:49.599 UTC] [D] 485AcReq <C3:01> PutOStream [6][0f000001000000090110278e0001020037]
[2026-08-01 17:57:49.600 UTC] [D] 485AcReq <C3:02> PutOStream [6][0f000001000000090110278e0001020037]
[2026-08-01 17:57:49.601 UTC] [D] 485AcReq <C3:03> PutOStream [6][0f000001000000090110278e0001020041]
[2026-08-01 17:57:49.601 UTC] [D] 485AcReq <C3:04> PutOStream [6][0f000001000000090110278e0001020036]
[2026-08-01 17:57:49.655 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:57:49.656 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:57:49.755 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:57:49.755 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:57:49.774 UTC] [V] 485DevCtl <C3:01> AnalyzeResponseData proc restart cnt:17949 UPRstat:0
[2026-08-01 17:57:49.776 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:57:49.777 UTC] [D] 485DevCtl <C3:01> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:57:49.777 UTC] [D] 485DevCtl <C3:01> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:57:49.777 UTC] [V] 485DevCtl <C3:01> device_type:Battery
[2026-08-01 17:57:49.778 UTC] [V] 485DevCtl <C3:02> AnalyzeResponseData proc restart cnt:17949 UPRstat:0
[2026-08-01 17:57:49.804 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:57:49.808 UTC] [D] 485DevCtl <C3:02> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:57:49.809 UTC] [D] 485DevCtl <C3:02> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:57:49.810 UTC] [V] 485DevCtl <C3:02> device_type:Battery
[2026-08-01 17:57:49.815 UTC] [V] 485DevCtl <C3:03> AnalyzeResponseData proc restart cnt:17949 UPRstat:0
[2026-08-01 17:57:49.823 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:57:49.839 UTC] [D] 485DevCtl <C3:03> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:57:49.844 UTC] [D] 485DevCtl <C3:03> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:57:49.848 UTC] [V] 485DevCtl <C3:03> device_type:Battery
[2026-08-01 17:57:49.848 UTC] [V] 485DevCtl <C3:04> AnalyzeResponseData proc restart cnt:17949 UPRstat:0
[2026-08-01 17:57:49.855 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:57:49.855 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:57:49.866 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:57:49.867 UTC] [D] 485DevCtl <C3:04> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:57:49.867 UTC] [D] 485DevCtl <C3:04> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:57:49.867 UTC] [V] 485DevCtl <C3:04> device_type:Battery
[2026-08-01 17:57:49.878 UTC] [V] 485ChCtl <C3> set rt:0
[2026-08-01 17:57:49.955 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:57:49.955 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:57:49.975 UTC] [I] SSLC Snd summ dat end.
[2026-08-01 17:57:50.012 UTC] [V] OFSCtrl [/var/local/solajithome/function/output_fluctuation_suppression/batt_data] write success.
[2026-08-01 17:57:50.055 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:57:50.055 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:57:50.155 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:57:50.155 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:57:50.179 UTC] [V] 485ChCtl <C3> StartDeviceCommunicationForOutputFluctuationSuppressionControlBroadcast 4 cnt:179444, monitor_cnt:50, bc_elapsed:179444, min:10, max:40
[2026-08-01 17:57:50.179 UTC] [V] OFSCtrl /var/local/solajithome/function/output_fluctuation_suppression/state is exist:0
[2026-08-01 17:57:50.180 UTC] [V] 485DevCtl <C3:01> Dev not PCS IsNeedToChangeOControlState
[2026-08-01 17:57:50.180 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :3
[2026-08-01 17:57:50.181 UTC] [V] 485ChCtl <C3> send request:Sungrow11
[2026-08-01 17:57:50.181 UTC] [D] 485AcReq <C3:01> PutOStream [3][0c00000100000006010435260018]
[2026-08-01 17:57:50.255 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:57:50.256 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:57:50.303 UTC] [V] 485DevCtl <C3:01> AnalyzeResponseData proc restart cnt:17949 UPRstat:0
[2026-08-01 17:57:50.308 UTC] [D] 485DevCtl <C3:01> RcvDat status[0] len[57] [0001000000330104301ebeffb501c203e81ebe01c200010001ffff4000ffff013b013bffff008c008c00640064ffff80027f9e012701180063]
[2026-08-01 17:57:50.308 UTC] [D] 485DevCtl <C3:01> ResCnd OperationId [3] IsNormal[1]  ConditionType [lggrdev:Normal] Action[-1]
[2026-08-01 17:57:50.311 UTC] [V] 485DevCtl <C3:01> [01][721100][7870.000000][1][V]
[2026-08-01 17:57:50.313 UTC] [V] SummDat SetVrmValue dev_id:13 val:787000.000000 sc:3
[2026-08-01 17:57:50.319 UTC] [V] OCMgr SetMeterValue PhId:0301, branchNo:01, valueId:721100, value:7870.000000, scaleFactor:1, devId:13
[2026-08-01 17:57:50.323 UTC] [V] 485DevCtl <C3:01> [01][721101][-75.000000][1][A]
[2026-08-01 17:57:50.325 UTC] [V] SummDat SetVrmValue dev_id:13 val:-7500.000000 sc:3
[2026-08-01 17:57:50.330 UTC] [V] OCMgr SetMeterValue PhId:0301, branchNo:01, valueId:721101, value:-75.000000, scaleFactor:1, devId:13
[2026-08-01 17:57:50.335 UTC] [V] OFSCtrl change set SOC(t):44.750000 drive cnt:4
[2026-08-01 17:57:50.338 UTC] [V] OFSCtrl Rcv set soc[0301]:45.000000
[2026-08-01 17:57:50.340 UTC] [V] 485DevCtl <C3:01> [01][721035][450.000000][1][%]
[2026-08-01 17:57:50.342 UTC] [V] SummDat SetVrmValue dev_id:13 val:45000.000000 sc:3
[2026-08-01 17:57:50.352 UTC] [V] OCMgr SetMeterValue PhId:0301, branchNo:01, valueId:721035, value:450.000000, scaleFactor:1, devId:13
[2026-08-01 17:57:50.353 UTC] [V] 485DevCtl <C3:01> [01][721036][1000.000000][1][%]
[2026-08-01 17:57:50.354 UTC] [V] SummDat SetVrmValue dev_id:13 val:100000.000000 sc:3
[2026-08-01 17:57:50.355 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:57:50.355 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:57:50.357 UTC] [V] OCMgr SetMeterValue PhId:0301, branchNo:01, valueId:721036, value:1000.000000, scaleFactor:1, devId:13
[2026-08-01 17:57:50.359 UTC] [V] 485DevCtl <C3:01> [01][721030][32770.000000][4][V]
[2026-08-01 17:57:50.362 UTC] [V] SummDat SetVrmValue dev_id:13 val:3277.000000 sc:3
[2026-08-01 17:57:50.365 UTC] [V] OCMgr SetMeterValue PhId:0301, branchNo:01, valueId:721030, value:32770.000000, scaleFactor:4, devId:13
[2026-08-01 17:57:50.368 UTC] [V] 485DevCtl <C3:01> [01][721031][32670.000000][4][V]
[2026-08-01 17:57:50.369 UTC] [V] SummDat SetVrmValue dev_id:13 val:3267.000000 sc:3
[2026-08-01 17:57:50.375 UTC] [V] OCMgr SetMeterValue PhId:0301, branchNo:01, valueId:721031, value:32670.000000, scaleFactor:4, devId:13
[2026-08-01 17:57:50.379 UTC] [V] 485DevCtl <C3:01> [01][721032][295.000000][1][℃]
[2026-08-01 17:57:50.380 UTC] [V] SummDat SetVrmValue dev_id:13 val:29500.000000 sc:3
[2026-08-01 17:57:50.386 UTC] [V] OCMgr SetMeterValue PhId:0301, branchNo:01, valueId:721032, value:295.000000, scaleFactor:1, devId:13
[2026-08-01 17:57:50.390 UTC] [V] 485DevCtl <C3:01> [01][721033][280.000000][1][℃]
[2026-08-01 17:57:50.391 UTC] [V] SummDat SetVrmValue dev_id:13 val:28000.000000 sc:3
[2026-08-01 17:57:50.397 UTC] [V] OCMgr SetMeterValue PhId:0301, branchNo:01, valueId:721033, value:280.000000, scaleFactor:1, devId:13
[2026-08-01 17:57:50.397 UTC] [V] 485DevCtl <C3:01> device_type:Battery
[2026-08-01 17:57:50.398 UTC] [V] 485ChCtl <C3> set rt:0
[2026-08-01 17:57:50.455 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:57:50.455 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:57:50.479 UTC] [V] 485ChCtl <C3> StartDeviceCommunicationForOutputFluctuationSuppressionControlBroadcast 4 cnt:179447, monitor_cnt:53, bc_elapsed:179447, min:10, max:40
[2026-08-01 17:57:50.479 UTC] [V] 485DevCtl <C3:02> Dev not PCS IsNeedToChangeOControlState
[2026-08-01 17:57:50.480 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :12
[2026-08-01 17:57:50.480 UTC] [V] 485ChCtl <C3> send request:Sungrow11
[2026-08-01 17:57:50.481 UTC] [D] 485AcReq <C3:02> PutOStream [12][0c00000100000006010427580001]
[2026-08-01 17:57:50.555 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:57:50.555 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:57:50.555 UTC] [V] OFSCtrl Control charge discharge proc start.
[2026-08-01 17:57:50.555 UTC] [V] OFSCtrl CHG 20 p_th(t):21274.050000 = p_th_old_:21264.150000 + lev_cd_:0.100000 * (total_pcs_capacity_:297000.000000 * cof_spec_:2.000000 / 60 * (time_threshold_renew:10.000000 * 10)), min:-2062.500000, max:407900.000000
[2026-08-01 17:57:50.556 UTC] [V] OFSCtrl CHG 21 batt_w:21926.549579 = old:21919.801079 +  kp:0.550000 * e:11.550000 + ki:0.000000 * sume:-11970.749857 + kd:0.040000 * (e:11.550000 - e1:1.650000)
[2026-08-01 17:57:50.556 UTC] [V] OFSCtrl CHG 21 battery threshold min:20000.000000 <= bat:21926.549579 <= max:196000.000000, adjust charge:0.000000, discharge:1000.000000
[2026-08-01 17:57:50.556 UTC] [V] OFSCtrl CHG 29 q:54.000000, mod(round):3.000000
[2026-08-01 17:57:50.556 UTC] [V] OFSCtrl discharge bat_w[0303]:6500.000000 += adjust:1000.000000
[2026-08-01 17:57:50.557 UTC] [D] OFSCtrl battery ctrl val:11.000000
[2026-08-01 17:57:50.557 UTC] [V] 485ChCtl <C3> battery limit on [55.000000,55.000000,65.000000,54.000000,] request.
[2026-08-01 17:57:50.557 UTC] [V] OFSCtrl Control charge discharge proc:01->02->BATT_CHK->03->04->05->06->10->12->13->15->16->17->20->21->22->23->24->25->27->23->24->25->27->23->24->25->27->23->24->25->27->28->29->30->31->32->30->31->32->30->31->32->30->31->32->33->34
[2026-08-01 17:57:50.613 UTC] [V] 485DevCtl <C3:02> AnalyzeResponseData proc restart cnt:17950 UPRstat:0
[2026-08-01 17:57:50.615 UTC] [D] 485DevCtl <C3:02> RcvDat status[0] len[11] [0001000000050104020010]
[2026-08-01 17:57:50.615 UTC] [D] 485DevCtl <C3:02> ResCnd OperationId [12] IsNormal[1]  ConditionType [lggrdev:Normal] Action[-1]
[2026-08-01 17:57:50.616 UTC] [V] 485DevCtl <C3:02> [02][753040][1.000000][0][]
[2026-08-01 17:57:50.616 UTC] [V] SummDat SetVrmValue dev_id:14 val:1.000000 sc:0
[2026-08-01 17:57:50.617 UTC] [V] OCMgr SetMeterValue PhId:0302, branchNo:02, valueId:753040, value:1.000000, scaleFactor:0, devId:14
[2026-08-01 17:57:50.618 UTC] [V] 485DevCtl <C3:02> device_type:Battery
[2026-08-01 17:57:50.632 UTC] [V] CIStDb UpdateStatusData. [SELECT no, on_time, off_time FROM contact_input_status WHERE no BETWEEN '1' AND '9' ORDER BY no ASC ]
[2026-08-01 17:57:50.636 UTC] [V] 485ChCtl <C3> set rt:0
[2026-08-01 17:57:50.655 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:57:50.655 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:57:50.679 UTC] [V] 485ChCtl <C3> battery send request.1
[2026-08-01 17:57:50.680 UTC] [D] VarInf Limit_Bat rt[2]set val[55] set rate[11.000000] value100[500] value-100[-500]
[2026-08-01 17:57:50.681 UTC] [D] VarInf Limit_Bat rt[2]set val[55] set rate[11.000000] value100[500] value-100[-500]
[2026-08-01 17:57:50.683 UTC] [D] VarInf Limit_Bat rt[2]set val[65] set rate[13.000000] value100[500] value-100[-500]
[2026-08-01 17:57:50.706 UTC] [D] VarInf Limit_Bat rt[2]set val[54] set rate[10.800000] value100[500] value-100[-500]
[2026-08-01 17:57:50.713 UTC] [D] 485AcReq <C3:01> PutOStream [6][0f000001000000090110278e0001020037]
[2026-08-01 17:57:50.714 UTC] [D] 485AcReq <C3:02> PutOStream [6][0f000001000000090110278e0001020037]
[2026-08-01 17:57:50.714 UTC] [D] 485AcReq <C3:03> PutOStream [6][0f000001000000090110278e0001020041]
[2026-08-01 17:57:50.716 UTC] [D] 485AcReq <C3:04> PutOStream [6][0f000001000000090110278e0001020036]
[2026-08-01 17:57:50.755 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:57:50.755 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:57:50.757 UTC] [V] 485DevCtl <C1:01> device_type:Irr-Meter
[2026-08-01 17:57:50.757 UTC] [V] 485DevCtl <C1:01> device_type:Irr-Meter
[2026-08-01 17:57:50.757 UTC] [V] 485ChCtl <C1> fixed cycle Irr-Meter
[2026-08-01 17:57:50.757 UTC] [V] 485DevCtl <C1:01> Dev not PCS IsNeedToChangeOControlState
[2026-08-01 17:57:50.757 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :1
[2026-08-01 17:57:50.758 UTC] [V] 485ChCtl <C1> send request:Irr01
[2026-08-01 17:57:50.759 UTC] [D] 485AcReq <C1:01> PutOStream [1][080001040000000271cb]
[2026-08-01 17:57:50.855 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:57:50.855 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:57:50.894 UTC] [V] 485DevCtl <C3:01> AnalyzeResponseData proc restart cnt:17950 UPRstat:0
[2026-08-01 17:57:50.897 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:57:50.897 UTC] [D] 485DevCtl <C3:01> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:57:50.897 UTC] [D] 485DevCtl <C3:01> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:57:50.898 UTC] [V] 485DevCtl <C3:01> device_type:Battery
[2026-08-01 17:57:50.899 UTC] [V] 485DevCtl <C3:02> AnalyzeResponseData proc restart cnt:17950 UPRstat:0
[2026-08-01 17:57:50.912 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:57:50.913 UTC] [D] 485DevCtl <C3:02> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:57:50.913 UTC] [D] 485DevCtl <C3:02> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:57:50.913 UTC] [V] 485DevCtl <C3:02> device_type:Battery
[2026-08-01 17:57:50.913 UTC] [V] 485DevCtl <C3:03> AnalyzeResponseData proc restart cnt:17950 UPRstat:0
[2026-08-01 17:57:50.930 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:57:50.936 UTC] [D] 485DevCtl <C3:03> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:57:50.937 UTC] [D] 485DevCtl <C3:03> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:57:50.939 UTC] [V] 485DevCtl <C3:03> device_type:Battery
[2026-08-01 17:57:50.944 UTC] [V] 485DevCtl <C3:04> AnalyzeResponseData proc restart cnt:17950 UPRstat:0
[2026-08-01 17:57:50.955 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:57:50.955 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:57:50.966 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:57:50.971 UTC] [D] 485DevCtl <C3:04> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:57:50.974 UTC] [D] 485DevCtl <C3:04> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:57:50.976 UTC] [V] 485DevCtl <C3:04> device_type:Battery
[2026-08-01 17:57:50.981 UTC] [V] 485ChCtl <C3> set rt:0
[2026-08-01 17:57:51.012 UTC] [V] OFSCtrl [/var/local/solajithome/function/output_fluctuation_suppression/batt_data] write success.
[2026-08-01 17:57:51.055 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:57:51.055 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:57:51.079 UTC] [V] 485ChCtl <C3> StartDeviceCommunicationForOutputFluctuationSuppressionControlBroadcast 4 cnt:179453, monitor_cnt:59, bc_elapsed:179453, min:10, max:40
[2026-08-01 17:57:51.079 UTC] [V] 485DevCtl <C3:03> Dev not PCS IsNeedToChangeOControlState
[2026-08-01 17:57:51.079 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :3
[2026-08-01 17:57:51.080 UTC] [V] 485ChCtl <C3> send request:Sungrow11
[2026-08-01 17:57:51.081 UTC] [D] 485AcReq <C3:03> PutOStream [3][0c00000100000006010435260018]
[2026-08-01 17:57:51.094 UTC] [V] 485DevCtl <C1:01> AnalyzeResponseData proc restart cnt:17968 UPRstat:0
[2026-08-01 17:57:51.094 UTC] [V] Res no response condition. set normal condition.
[2026-08-01 17:57:51.095 UTC] [D] 485DevCtl <C1:01> RcvDat status[2] len[9] [010404000001fa7a57]
[2026-08-01 17:57:51.095 UTC] [D] 485DevCtl <C1:01> ResCnd OperationId [1] IsNormal[1] 
[2026-08-01 17:57:51.096 UTC] [V] OFSCtrl Rcv set flux_of_solar:0.000000
[2026-08-01 17:57:51.096 UTC] [V] 485DevCtl <C1:01> [01][401006][0.000000][1][W/m2]
[2026-08-01 17:57:51.096 UTC] [V] SummDat SetVrmValue dev_id:1 val:0.000000 sc:3
[2026-08-01 17:57:51.096 UTC] [V] OCMgr SetMeterValue PhId:0101, branchNo:01, valueId:401006, value:0.000000, scaleFactor:1, devId:1
[2026-08-01 17:57:51.097 UTC] [V] 485DevCtl <C1:01> [01][421005][256.000000][1][℃]
[2026-08-01 17:57:51.097 UTC] [V] SummDat SetVrmValue dev_id:1 val:25600.000000 sc:3
[2026-08-01 17:57:51.097 UTC] [V] OCMgr SetMeterValue PhId:0101, branchNo:01, valueId:421005, value:256.000000, scaleFactor:1, devId:1
[2026-08-01 17:57:51.097 UTC] [V] 485DevCtl <C1:01> device_type:Irr-Meter
[2026-08-01 17:57:51.097 UTC] [V] OFSCtrl Irr-Meter received.
[2026-08-01 17:57:51.098 UTC] [V] 485ChCtl <C1> set rt:0
[2026-08-01 17:57:51.099 UTC] [V] 485DevCtl <C1:01> device_type:Irr-Meter
[2026-08-01 17:57:51.155 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:57:51.155 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:57:51.156 UTC] [V] 485DevCtl <C1:04> device_type:CO-Meter
[2026-08-01 17:57:51.156 UTC] [V] 485DevCtl <C1:04> device_type:CO-Meter
[2026-08-01 17:57:51.157 UTC] [V] 485ChCtl <C1> fixed cycle CO-Meter
[2026-08-01 17:57:51.157 UTC] [V] 485DevCtl <C1:04> Dev not PCS IsNeedToChangeOControlState
[2026-08-01 17:57:51.157 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :1
[2026-08-01 17:57:51.157 UTC] [V] 485ChCtl <C1> send request:omron05
[2026-08-01 17:57:51.158 UTC] [D] 485AcReq <C1:04> PutOStream [1][0800040300030014b590]
[2026-08-01 17:57:51.233 UTC] [V] 485DevCtl <C3:03> AnalyzeResponseData proc restart cnt:17950 UPRstat:0
[2026-08-01 17:57:51.237 UTC] [D] 485DevCtl <C3:03> RcvDat status[0] len[57] [0001000000330104301ebdffa801c203e81ebd01c200010001ffff4000ffff01360136ffff008c008c00640064ffff7fee7f9e011d010e0050]
[2026-08-01 17:57:51.237 UTC] [D] 485DevCtl <C3:03> ResCnd OperationId [3] IsNormal[1]  ConditionType [lggrdev:Normal] Action[-1]
[2026-08-01 17:57:51.237 UTC] [V] 485DevCtl <C3:03> [01][721100][7869.000000][1][V]
[2026-08-01 17:57:51.238 UTC] [V] SummDat SetVrmValue dev_id:15 val:786900.000000 sc:3
[2026-08-01 17:57:51.238 UTC] [V] OCMgr SetMeterValue PhId:0303, branchNo:01, valueId:721100, value:7869.000000, scaleFactor:1, devId:15
[2026-08-01 17:57:51.238 UTC] [V] 485DevCtl <C3:03> [01][721101][-88.000000][1][A]
[2026-08-01 17:57:51.238 UTC] [V] SummDat SetVrmValue dev_id:15 val:-8800.000000 sc:3
[2026-08-01 17:57:51.239 UTC] [V] OCMgr SetMeterValue PhId:0303, branchNo:01, valueId:721101, value:-88.000000, scaleFactor:1, devId:15
[2026-08-01 17:57:51.239 UTC] [V] OFSCtrl change set SOC(t):44.750000 drive cnt:4
[2026-08-01 17:57:51.239 UTC] [V] OFSCtrl Rcv set soc[0303]:45.000000
[2026-08-01 17:57:51.239 UTC] [V] 485DevCtl <C3:03> [01][721035][450.000000][1][%]
[2026-08-01 17:57:51.240 UTC] [V] SummDat SetVrmValue dev_id:15 val:45000.000000 sc:3
[2026-08-01 17:57:51.240 UTC] [V] OCMgr SetMeterValue PhId:0303, branchNo:01, valueId:721035, value:450.000000, scaleFactor:1, devId:15
[2026-08-01 17:57:51.240 UTC] [V] 485DevCtl <C3:03> [01][721036][1000.000000][1][%]
[2026-08-01 17:57:51.240 UTC] [V] SummDat SetVrmValue dev_id:15 val:100000.000000 sc:3
[2026-08-01 17:57:51.241 UTC] [V] OCMgr SetMeterValue PhId:0303, branchNo:01, valueId:721036, value:1000.000000, scaleFactor:1, devId:15
[2026-08-01 17:57:51.241 UTC] [V] 485DevCtl <C3:03> [01][721030][32750.000000][4][V]
[2026-08-01 17:57:51.241 UTC] [V] SummDat SetVrmValue dev_id:15 val:3275.000000 sc:3
[2026-08-01 17:57:51.241 UTC] [V] OCMgr SetMeterValue PhId:0303, branchNo:01, valueId:721030, value:32750.000000, scaleFactor:4, devId:15
[2026-08-01 17:57:51.241 UTC] [V] 485DevCtl <C3:03> [01][721031][32670.000000][4][V]
[2026-08-01 17:57:51.241 UTC] [V] SummDat SetVrmValue dev_id:15 val:3267.000000 sc:3
[2026-08-01 17:57:51.255 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:57:51.256 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:57:51.279 UTC] [V] OCMgr SetMeterValue PhId:0303, branchNo:01, valueId:721031, value:32670.000000, scaleFactor:4, devId:15
[2026-08-01 17:57:51.280 UTC] [V] 485DevCtl <C3:03> [01][721032][285.000000][1][℃]
[2026-08-01 17:57:51.280 UTC] [V] SummDat SetVrmValue dev_id:15 val:28500.000000 sc:3
[2026-08-01 17:57:51.280 UTC] [V] OCMgr SetMeterValue PhId:0303, branchNo:01, valueId:721032, value:285.000000, scaleFactor:1, devId:15
[2026-08-01 17:57:51.281 UTC] [V] 485DevCtl <C3:03> [01][721033][270.000000][1][℃]
[2026-08-01 17:57:51.281 UTC] [V] SummDat SetVrmValue dev_id:15 val:27000.000000 sc:3
[2026-08-01 17:57:51.281 UTC] [V] OCMgr SetMeterValue PhId:0303, branchNo:01, valueId:721033, value:270.000000, scaleFactor:1, devId:15
[2026-08-01 17:57:51.282 UTC] [V] 485DevCtl <C3:03> device_type:Battery
[2026-08-01 17:57:51.315 UTC] [V] 485ChCtl <C3> set rt:0
[2026-08-01 17:57:51.355 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:57:51.356 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:57:51.379 UTC] [V] 485ChCtl <C3> StartDeviceCommunicationForOutputFluctuationSuppressionControlBroadcast 4 cnt:179456, monitor_cnt:62, bc_elapsed:179456, min:10, max:40
[2026-08-01 17:57:51.379 UTC] [V] 485DevCtl <C3:04> Dev not PCS IsNeedToChangeOControlState
[2026-08-01 17:57:51.379 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :4
[2026-08-01 17:57:51.380 UTC] [V] 485ChCtl <C3> send request:Sungrow11
[2026-08-01 17:57:51.381 UTC] [D] 485AcReq <C3:04> PutOStream [4][0c00000100000006010427f0002f]
[2026-08-01 17:57:51.455 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:57:51.456 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:57:51.503 UTC] [V] 485DevCtl <C3:04> AnalyzeResponseData proc restart cnt:17950 UPRstat:0
[2026-08-01 17:57:51.517 UTC] [D] 485DevCtl <C3:04> RcvDat status[0] len[103] [00010000006101045e1e870047003710000fbb1034004e004e004d003600010000000000000000000000000001000000ae448900003e320000012c0000006700ac182900000001177103e701d3000000ac034200000e9d0000ed59000100350000000000ae0000]
[2026-08-01 17:57:51.521 UTC] [D] 485DevCtl <C3:04> ResCnd OperationId [4] IsNormal[1]  ConditionType [lggrdev:Normal] Action[-1]
[2026-08-01 17:57:51.527 UTC] [V] 485DevCtl <C3:04> [05][753053][0.000000][0][]
[2026-08-01 17:57:51.530 UTC] [V] SummDat SetVrmValue dev_id:16 val:0.000000 sc:0
[2026-08-01 17:57:51.533 UTC] [V] OCMgr SetMeterValue PhId:0304, branchNo:05, valueId:753053, value:0.000000, scaleFactor:0, devId:16
[2026-08-01 17:57:51.533 UTC] [V] 485DevCtl <C3:04> [06][753053][0.000000][0][]
[2026-08-01 17:57:51.542 UTC] [V] SummDat SetVrmValue dev_id:16 val:0.000000 sc:0
[2026-08-01 17:57:51.543 UTC] [V] OCMgr SetMeterValue PhId:0304, branchNo:06, valueId:753053, value:0.000000, scaleFactor:0, devId:16
[2026-08-01 17:57:51.546 UTC] [V] 485DevCtl <C3:04> [07][753053][0.000000][0][]
[2026-08-01 17:57:51.548 UTC] [V] SummDat SetVrmValue dev_id:16 val:0.000000 sc:0
[2026-08-01 17:57:51.554 UTC] [V] OCMgr SetMeterValue PhId:0304, branchNo:07, valueId:753053, value:0.000000, scaleFactor:0, devId:16
[2026-08-01 17:57:51.555 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:57:51.555 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:57:51.555 UTC] [V] OFSCtrl Control charge discharge proc start.
[2026-08-01 17:57:51.556 UTC] [V] OFSCtrl CHG 20 p_th(t):21283.950000 = p_th_old_:21274.050000 + lev_cd_:0.100000 * (total_pcs_capacity_:297000.000000 * cof_spec_:2.000000 / 60 * (time_threshold_renew:10.000000 * 10)), min:-2062.500000, max:407900.000000
[2026-08-01 17:57:51.556 UTC] [V] OFSCtrl CHG 21 batt_w:21938.743079 = old:21926.549579 +  kp:0.550000 * e:21.450000 + ki:0.000000 * sume:-11949.299857 + kd:0.040000 * (e:21.450000 - e1:11.550000)
[2026-08-01 17:57:51.556 UTC] [V] OFSCtrl CHG 21 battery threshold min:20000.000000 <= bat:21938.743079 <= max:196000.000000, adjust charge:0.000000, discharge:1000.000000
[2026-08-01 17:57:51.557 UTC] [V] OFSCtrl CHG 29 q:54.000000, mod(round):3.000000
[2026-08-01 17:57:51.557 UTC] [V] OFSCtrl discharge bat_w[0303]:6500.000000 += adjust:1000.000000
[2026-08-01 17:57:51.557 UTC] [D] OFSCtrl battery ctrl val:11.000000
[2026-08-01 17:57:51.557 UTC] [V] 485ChCtl <C3> battery limit on [55.000000,55.000000,65.000000,54.000000,] request.
[2026-08-01 17:57:51.557 UTC] [V] OFSCtrl Control charge discharge proc:01->02->BATT_CHK->03->04->05->06->10->12->13->15->16->17->20->21->22->23->24->25->27->23->24->25->27->23->24->25->27->23->24->25->27->28->29->30->31->32->30->31->32->30->31->32->30->31->32->33->34
[2026-08-01 17:57:51.564 UTC] [V] 485DevCtl <C1:04> AnalyzeResponseData proc restart cnt:17968 UPRstat:0
[2026-08-01 17:57:51.565 UTC] [V] Res no response condition. set normal condition.
[2026-08-01 17:57:51.566 UTC] [D] 485DevCtl <C1:04> RcvDat status[2] len[45] [0403280000f48b0000fbbf0000e3d90000006400000258000349ba0000086affffbea5ffffff5900233b02d612]
[2026-08-01 17:57:51.566 UTC] [D] 485DevCtl <C1:04> ResCnd OperationId [1] IsNormal[1] 
[2026-08-01 17:57:51.566 UTC] [V] OFSCtrl Rcv set p_co:21540.000000, p_co_old:21520.000000
[2026-08-01 17:57:51.566 UTC] [V] 485DevCtl <C1:04> [01][601260][2154.000000][2][kW]
[2026-08-01 17:57:51.567 UTC] [V] SummDat SetVrmValue dev_id:4 val:21540.000000 sc:3
[2026-08-01 17:57:51.567 UTC] [V] OCMgr SetMeterValue PhId:0104, branchNo:01, valueId:601260, value:2154.000000, scaleFactor:2, devId:4
[2026-08-01 17:57:51.567 UTC] [V] 485DevCtl <C1:04> [01][603260][2308866.000000][1][kWh]
[2026-08-01 17:57:51.567 UTC] [V] SummDat SetVrmValue dev_id:4 val:2308866.000000 sc:1
[2026-08-01 17:57:51.567 UTC] [V] OCMgr SetMeterValue PhId:0104, branchNo:01, valueId:603260, value:2308866.000000, scaleFactor:1, devId:4
[2026-08-01 17:57:51.568 UTC] [V] 485DevCtl <C1:04> device_type:CO-Meter
[2026-08-01 17:57:51.568 UTC] [V] OFSCtrl km50 received.
[2026-08-01 17:57:51.568 UTC] [V] OFSCtrl omron05_local_date :2026/08/02 ? 2026/08/02
[2026-08-01 17:57:51.568 UTC] [V] OFSCtrl omron05_local_time :2026/08/02 02 ? 2026/08/02 02
[2026-08-01 17:57:51.568 UTC] [V] OFSCtrl out of control time.
[2026-08-01 17:57:51.568 UTC] [V] OFSCtrl Control pv-pcs proc start.
[2026-08-01 17:57:51.568 UTC] [V] OFSCtrl NOD_month:-445.000000 = (NOD_month:13 - ((nod_max_/30):23.333333 * (cnt-1):12) * (30/cnt):1.666667 
[2026-08-01 17:57:51.569 UTC] [V] OFSCtrl PCS ratio_month:113.496241 = -k_inhibition_ratio_month:-0.097744 * NOD_month:-445.000000 + inhibition_ratio_max:70
[2026-08-01 17:57:51.569 UTC] [V] OFSCtrl PCS 05 inhibition_ratio:70.000000 = max(ratio_min:5, min(ratio:70, ratio_hour:70.000000, ratio_day:70.000000, ratio_month:113.496241))
[2026-08-01 17:57:51.569 UTC] [D] OFSCtrl pv-pcs ctrl val:0.000000 old:0.000000
[2026-08-01 17:57:51.569 UTC] [V] OCHisDB set rate:0 t_rate:0 cnt:31
[2026-08-01 17:57:51.569 UTC] [V] 485ChCtl <C2> pv-pcs limit on [0.000000] request.
[2026-08-01 17:57:51.569 UTC] [V] OFSCtrl Control pv-pcs proc:BATT_CHK->01->02->03->04->05->06->07->09->09->10->11->12
[2026-08-01 17:57:51.570 UTC] [V] 485ChCtl <C2> pv-pcs send request.
[2026-08-01 17:57:51.570 UTC] [D] VarInf update ofs_rate:0.000000
[2026-08-01 17:57:51.570 UTC] [V] VarInf LimitSet rt[2] val[170] key[ValueOn]
[2026-08-01 17:57:51.570 UTC] [D] VarInf output_mode:8
[2026-08-01 17:57:51.570 UTC] [D] VarInf update ofs_rate:0.000000
[2026-08-01 17:57:51.570 UTC] [D] VarInf Limit setRate[0.000000] rate[0.000000] value100[1000.000000] value0[0.000000]
[2026-08-01 17:57:51.570 UTC] [V] 485DevCtl <C2:01> ChangeOutputRateToDevice rate:0.000000 set_rate1
[2026-08-01 17:57:51.571 UTC] [D] VarInf Limit rt[2] int_set_rate[1] server_rate[0.000000] rated_output[100.000000] solar_battery_power[100.000000]
[2026-08-01 17:57:51.573 UTC] [D] 485AcReq <C2:01> PutOStreamForBc [3][0d000010138e00020400aa0001466f]
[2026-08-01 17:57:51.576 UTC] [V] 485DevCtl <C3:04> device_type:Battery
[2026-08-01 17:57:51.586 UTC] [V] 485DevCtl <C3:04> set2 StatusCode[020101]
[2026-08-01 17:57:51.587 UTC] [V] OFSCtrl Bat[0304] StCd[020101]->st[1].
[2026-08-01 17:57:51.587 UTC] [V] OFSCtrl set batt status:[0304]:Drive, All:[0301]:Drive,[0302]:Drive,[0303]:Drive,[0304]:Drive, [DRIVE] 
[2026-08-01 17:57:51.587 UTC] [V] OFSCtrl change set SOC(t):44.750000 drive cnt:4
[2026-08-01 17:57:51.588 UTC] [V] 485DevCtl <C3:04> set2 StatusCode[020101] DeviceName[蓄電池4] DeviceNumber[1]
[2026-08-01 17:57:51.588 UTC] [V] 485ChCtl <C3> set rt:0
[2026-08-01 17:57:51.602 UTC] [D] 485ChCtl <C3> monitoring dev All Send
[2026-08-01 17:57:51.601 UTC] [V] 485ChCtl <C1> set rt:0
[2026-08-01 17:57:51.604 UTC] [V] 485DevCtl <C1:04> device_type:CO-Meter
[2026-08-01 17:57:51.655 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:57:51.655 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:57:51.678 UTC] [V] 485ChCtl <C3> battery send request.1
[2026-08-01 17:57:51.679 UTC] [D] VarInf Limit_Bat rt[2]set val[55] set rate[11.000000] value100[500] value-100[-500]
[2026-08-01 17:57:51.680 UTC] [D] VarInf Limit_Bat rt[2]set val[55] set rate[11.000000] value100[500] value-100[-500]
[2026-08-01 17:57:51.683 UTC] [D] VarInf Limit_Bat rt[2]set val[65] set rate[13.000000] value100[500] value-100[-500]
[2026-08-01 17:57:51.695 UTC] [D] VarInf Limit_Bat rt[2]set val[54] set rate[10.800000] value100[500] value-100[-500]
[2026-08-01 17:57:51.702 UTC] [D] 485AcReq <C3:01> PutOStream [6][0f000001000000090110278e0001020037]
[2026-08-01 17:57:51.702 UTC] [D] 485AcReq <C3:02> PutOStream [6][0f000001000000090110278e0001020037]
[2026-08-01 17:57:51.703 UTC] [D] 485AcReq <C3:03> PutOStream [6][0f000001000000090110278e0001020041]
[2026-08-01 17:57:51.707 UTC] [D] 485AcReq <C3:04> PutOStream [6][0f000001000000090110278e0001020036]
[2026-08-01 17:57:51.755 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:57:51.755 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:57:51.855 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:57:51.855 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:57:51.868 UTC] [V] 485ChCtl <C2> set rt:0
[2026-08-01 17:57:51.875 UTC] [V] 485DevCtl <C3:01> AnalyzeResponseData proc restart cnt:17951 UPRstat:0
[2026-08-01 17:57:51.879 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:57:51.880 UTC] [D] 485DevCtl <C3:01> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:57:51.881 UTC] [D] 485DevCtl <C3:01> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:57:51.882 UTC] [V] 485DevCtl <C3:01> device_type:Battery
[2026-08-01 17:57:51.889 UTC] [V] 485DevCtl <C3:02> AnalyzeResponseData proc restart cnt:17951 UPRstat:0
[2026-08-01 17:57:51.903 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:57:51.912 UTC] [D] 485DevCtl <C3:02> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:57:51.914 UTC] [D] 485DevCtl <C3:02> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:57:51.918 UTC] [V] 485DevCtl <C3:02> device_type:Battery
[2026-08-01 17:57:51.922 UTC] [V] 485DevCtl <C3:03> AnalyzeResponseData proc restart cnt:17951 UPRstat:0
[2026-08-01 17:57:51.923 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:57:51.940 UTC] [D] 485DevCtl <C3:03> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:57:51.948 UTC] [D] 485DevCtl <C3:03> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:57:51.949 UTC] [V] 485DevCtl <C3:03> device_type:Battery
[2026-08-01 17:57:51.949 UTC] [V] 485DevCtl <C3:04> AnalyzeResponseData proc restart cnt:17951 UPRstat:0
[2026-08-01 17:57:51.955 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:57:51.956 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:57:51.964 UTC] [V] 485ChCtl <C2> StartDeviceCommunicationForOutputFluctuationSuppressionControlBroadcast 4 cnt:179462, monitor_cnt:54, bc_elapsed:179462, min:10, max:40
[2026-08-01 17:57:51.965 UTC] [V] OFSCtrl /var/local/solajithome/function/output_fluctuation_suppression/state is exist:0
[2026-08-01 17:57:51.965 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :1
[2026-08-01 17:57:51.966 UTC] [V] 485ChCtl <C2> send request:Sungrow08
[2026-08-01 17:57:51.967 UTC] [D] 485AcReq <C2:01> PutOStream [1][08000104138a0024d57f]
[2026-08-01 17:57:51.970 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:57:51.971 UTC] [D] 485DevCtl <C3:04> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:57:51.971 UTC] [D] 485DevCtl <C3:04> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:57:51.971 UTC] [V] 485DevCtl <C3:04> device_type:Battery
[2026-08-01 17:57:51.971 UTC] [V] 485ChCtl <C3> set rt:0
[2026-08-01 17:57:52.012 UTC] [V] OFSCtrl [/var/local/solajithome/function/output_fluctuation_suppression/batt_data] write success.
[2026-08-01 17:57:52.055 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:57:52.055 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:57:52.155 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:57:52.155 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:57:52.255 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:57:52.255 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:57:52.355 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:57:52.355 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:57:52.370 UTC] [V] Res no response condition. set normal condition.
[2026-08-01 17:57:52.373 UTC] [D] 485DevCtl <C2:01> RcvDat status[2] len[77] [0104480000c1350000127a000000000000000000000000000000000000000000000000000000000000000000000000ffffffffffffffffffffffff00000000000000000000000000001400e9da]
[2026-08-01 17:57:52.374 UTC] [D] 485DevCtl <C2:01> ResCnd OperationId [1] IsNormal[1] 
[2026-08-01 17:57:52.376 UTC] [V] 485DevCtl <C2:01> [01][115202][0.000000][1][kWh]
[2026-08-01 17:57:52.380 UTC] [V] SummDat SetVrmValue dev_id:7 val:0.000000 sc:1
[2026-08-01 17:57:52.386 UTC] [V] OCMgr SetMeterValue PhId:0201, branchNo:01, valueId:115202, value:0.000000, scaleFactor:1, devId:7
[2026-08-01 17:57:52.396 UTC] [V] 485DevCtl <C2:01> [01][113202][49461.000000][0][kWh]
[2026-08-01 17:57:52.399 UTC] [V] SummDat SetVrmValue dev_id:7 val:49461.000000 sc:0
[2026-08-01 17:57:52.401 UTC] [V] OCMgr SetMeterValue PhId:0201, branchNo:01, valueId:113202, value:49461.000000, scaleFactor:0, devId:7
[2026-08-01 17:57:52.405 UTC] [V] 485DevCtl <C2:01> [01][121005][0.000000][1][℃]
[2026-08-01 17:57:52.408 UTC] [V] SummDat SetVrmValue dev_id:7 val:0.000000 sc:3
[2026-08-01 17:57:52.411 UTC] [V] OCMgr SetMeterValue PhId:0201, branchNo:01, valueId:121005, value:0.000000, scaleFactor:1, devId:7
[2026-08-01 17:57:52.418 UTC] [V] 485DevCtl <C2:01> [01][101100][0.000000][1][V]
[2026-08-01 17:57:52.418 UTC] [V] SummDat SetVrmValue dev_id:7 val:0.000000 sc:3
[2026-08-01 17:57:52.419 UTC] [V] OCMgr SetMeterValue PhId:0201, branchNo:01, valueId:101100, value:0.000000, scaleFactor:1, devId:7
[2026-08-01 17:57:52.421 UTC] [V] 485DevCtl <C2:01> [01][101101][0.000000][1][A]
[2026-08-01 17:57:52.422 UTC] [V] SummDat SetVrmValue dev_id:7 val:0.000000 sc:3
[2026-08-01 17:57:52.424 UTC] [V] OCMgr SetMeterValue PhId:0201, branchNo:01, valueId:101101, value:0.000000, scaleFactor:1, devId:7
[2026-08-01 17:57:52.426 UTC] [V] 485DevCtl <C2:01> [02][101100][0.000000][1][V]
[2026-08-01 17:57:52.427 UTC] [V] SummDat SetVrmValue dev_id:7 val:0.000000 sc:3
[2026-08-01 17:57:52.432 UTC] [V] OCMgr SetMeterValue PhId:0201, branchNo:02, valueId:101100, value:0.000000, scaleFactor:1, devId:7
[2026-08-01 17:57:52.435 UTC] [V] 485DevCtl <C2:01> [02][101101][0.000000][1][A]
[2026-08-01 17:57:52.437 UTC] [V] SummDat SetVrmValue dev_id:7 val:0.000000 sc:3
[2026-08-01 17:57:52.442 UTC] [V] OCMgr SetMeterValue PhId:0201, branchNo:02, valueId:101101, value:0.000000, scaleFactor:1, devId:7
[2026-08-01 17:57:52.446 UTC] [V] 485DevCtl <C2:01> [03][101100][0.000000][1][V]
[2026-08-01 17:57:52.447 UTC] [V] SummDat SetVrmValue dev_id:7 val:0.000000 sc:3
[2026-08-01 17:57:52.452 UTC] [V] OCMgr SetMeterValue PhId:0201, branchNo:03, valueId:101100, value:0.000000, scaleFactor:1, devId:7
[2026-08-01 17:57:52.452 UTC] [V] 485DevCtl <C2:01> [03][101101][0.000000][1][A]
[2026-08-01 17:57:52.452 UTC] [V] SummDat SetVrmValue dev_id:7 val:0.000000 sc:3
[2026-08-01 17:57:52.453 UTC] [V] OCMgr SetMeterValue PhId:0201, branchNo:03, valueId:101101, value:0.000000, scaleFactor:1, devId:7
[2026-08-01 17:57:52.453 UTC] [V] 485DevCtl <C2:01> [01][101102][0.000000][0][W]
[2026-08-01 17:57:52.455 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:57:52.455 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:57:52.457 UTC] [V] SummDat SetVrmValue dev_id:7 val:0.000000 sc:3
[2026-08-01 17:57:52.463 UTC] [V] OCMgr SetMeterValue PhId:0201, branchNo:01, valueId:101102, value:0.000000, scaleFactor:0, devId:7
[2026-08-01 17:57:52.466 UTC] [V] 485DevCtl <C2:01> [01][111200][0.000000][1][V]
[2026-08-01 17:57:52.467 UTC] [V] SummDat SetVrmValue dev_id:7 val:0.000000 sc:3
[2026-08-01 17:57:52.471 UTC] [V] OCMgr SetMeterValue PhId:0201, branchNo:01, valueId:111200, value:0.000000, scaleFactor:1, devId:7
[2026-08-01 17:57:52.476 UTC] [V] 485DevCtl <C2:01> [02][111200][0.000000][1][V]
[2026-08-01 17:57:52.477 UTC] [V] SummDat SetVrmValue dev_id:7 val:0.000000 sc:3
[2026-08-01 17:57:52.478 UTC] [V] OCMgr SetMeterValue PhId:0201, branchNo:02, valueId:111200, value:0.000000, scaleFactor:1, devId:7
[2026-08-01 17:57:52.485 UTC] [V] 485DevCtl <C2:01> [03][111200][0.000000][1][V]
[2026-08-01 17:57:52.486 UTC] [V] SummDat SetVrmValue dev_id:7 val:0.000000 sc:3
[2026-08-01 17:57:52.489 UTC] [V] OCMgr SetMeterValue PhId:0201, branchNo:03, valueId:111200, value:0.000000, scaleFactor:1, devId:7
[2026-08-01 17:57:52.490 UTC] [V] 485DevCtl <C2:01> [01][111201][0.000000][1][A]
[2026-08-01 17:57:52.491 UTC] [V] SummDat SetVrmValue dev_id:7 val:0.000000 sc:3
[2026-08-01 17:57:52.495 UTC] [V] OCMgr SetMeterValue PhId:0201, branchNo:01, valueId:111201, value:0.000000, scaleFactor:1, devId:7
[2026-08-01 17:57:52.498 UTC] [V] 485DevCtl <C2:01> [02][111201][0.000000][1][A]
[2026-08-01 17:57:52.500 UTC] [V] SummDat SetVrmValue dev_id:7 val:0.000000 sc:3
[2026-08-01 17:57:52.504 UTC] [V] OCMgr SetMeterValue PhId:0201, branchNo:02, valueId:111201, value:0.000000, scaleFactor:1, devId:7
[2026-08-01 17:57:52.508 UTC] [V] 485DevCtl <C2:01> [03][111201][0.000000][1][A]
[2026-08-01 17:57:52.509 UTC] [V] SummDat SetVrmValue dev_id:7 val:0.000000 sc:3
[2026-08-01 17:57:52.511 UTC] [V] OCMgr SetMeterValue PhId:0201, branchNo:03, valueId:111201, value:0.000000, scaleFactor:1, devId:7
[2026-08-01 17:57:52.512 UTC] [V] 485DevCtl <C2:01> [01][111202][0.000000][0][W]
[2026-08-01 17:57:52.512 UTC] [V] SummDat SetVrmValue dev_id:7 val:0.000000 sc:3
[2026-08-01 17:57:52.515 UTC] [V] OCMgr SetMeterValue PhId:0201, branchNo:01, valueId:111202, value:0.000000, scaleFactor:0, devId:7
[2026-08-01 17:57:52.517 UTC] [V] 485DevCtl <C2:01> [01][111203][0.000000][0][var]
[2026-08-01 17:57:52.519 UTC] [V] SummDat SetVrmValue dev_id:7 val:0.000000 sc:3
[2026-08-01 17:57:52.522 UTC] [V] OCMgr SetMeterValue PhId:0201, branchNo:01, valueId:111203, value:0.000000, scaleFactor:0, devId:7
[2026-08-01 17:57:52.526 UTC] [V] 485DevCtl <C2:01> [01][121007][0.000000][3][]
[2026-08-01 17:57:52.528 UTC] [V] SummDat SetVrmValue dev_id:7 val:0.000000 sc:3
[2026-08-01 17:57:52.532 UTC] [V] OCMgr SetMeterValue PhId:0201, branchNo:01, valueId:121007, value:0.000000, scaleFactor:3, devId:7
[2026-08-01 17:57:52.535 UTC] [V] 485DevCtl <C2:01> [01][131006][0.000000][1][Hz]
[2026-08-01 17:57:52.537 UTC] [V] SummDat SetVrmValue dev_id:7 val:0.000000 sc:3
[2026-08-01 17:57:52.541 UTC] [V] OCMgr SetMeterValue PhId:0201, branchNo:01, valueId:131006, value:0.000000, scaleFactor:1, devId:7
[2026-08-01 17:57:52.545 UTC] [V] 485DevCtl <C2:01> [01][114202][49461.000000][0][kWh]
[2026-08-01 17:57:52.545 UTC] [V] SummDat SetVrmValue dev_id:7 val:49461000.000000 sc:3
[2026-08-01 17:57:52.545 UTC] [V] OCMgr SetMeterValue PhId:0201, branchNo:01, valueId:114202, value:49461.000000, scaleFactor:0, devId:7
[2026-08-01 17:57:52.545 UTC] [V] 485DevCtl <C2:01> device_type:PV-PCS
[2026-08-01 17:57:52.546 UTC] [V] 485DevCtl <C2:01> set2 StatusCode[010100] DeviceName[] DeviceNumber[]
[2026-08-01 17:57:52.547 UTC] [V] 485ChCtl <C2> set rt:0
[2026-08-01 17:57:52.555 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:57:52.555 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:57:52.555 UTC] [V] OFSCtrl Control charge discharge proc start.
[2026-08-01 17:57:52.556 UTC] [V] OFSCtrl CHG 20 p_th(t):21293.850000 = p_th_old_:21283.950000 + lev_cd_:0.100000 * (total_pcs_capacity_:297000.000000 * cof_spec_:2.000000 / 60 * (time_threshold_renew:10.000000 * 10)), min:-2062.500000, max:407900.000000
[2026-08-01 17:57:52.556 UTC] [V] OFSCtrl CHG 21 batt_w:21956.381579 = old:21938.743079 +  kp:0.550000 * e:31.350000 + ki:0.000000 * sume:-11917.949857 + kd:0.040000 * (e:31.350000 - e1:21.450000)
[2026-08-01 17:57:52.556 UTC] [V] OFSCtrl CHG 21 battery threshold min:20000.000000 <= bat:21956.381579 <= max:196000.000000, adjust charge:0.000000, discharge:1000.000000
[2026-08-01 17:57:52.556 UTC] [V] OFSCtrl CHG 29 q:54.000000, mod(round):4.000000
[2026-08-01 17:57:52.557 UTC] [V] OFSCtrl discharge bat_w[0303]:6500.000000 += adjust:1000.000000
[2026-08-01 17:57:52.557 UTC] [D] OFSCtrl battery ctrl val:11.000000
[2026-08-01 17:57:52.559 UTC] [V] 485ChCtl <C3> battery limit on [55.000000,55.000000,65.000000,55.000000,] request.
[2026-08-01 17:57:52.561 UTC] [V] OFSCtrl Control charge discharge proc:01->02->BATT_CHK->03->04->05->06->10->12->13->15->16->17->20->21->22->23->24->25->27->23->24->25->27->23->24->25->27->23->24->25->27->28->29->30->31->32->30->31->32->30->31->32->30->31->32->33->34
[2026-08-01 17:57:52.564 UTC] [V] 485ChCtl <C2> StartDeviceCommunicationForOutputFluctuationSuppressionControlBroadcast 4 cnt:179468, monitor_cnt:60, bc_elapsed:179468, min:10, max:40
[2026-08-01 17:57:52.564 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :1
[2026-08-01 17:57:52.565 UTC] [V] 485ChCtl <C2> send request:Sungrow08
[2026-08-01 17:57:52.570 UTC] [D] 485AcReq <C2:02> PutOStream [1][08000204138a0024d54c]
[2026-08-01 17:57:52.578 UTC] [V] 485ChCtl <C3> battery send request.1
[2026-08-01 17:57:52.579 UTC] [D] VarInf Limit_Bat rt[2]set val[55] set rate[11.000000] value100[500] value-100[-500]
[2026-08-01 17:57:52.580 UTC] [D] VarInf Limit_Bat rt[2]set val[55] set rate[11.000000] value100[500] value-100[-500]
[2026-08-01 17:57:52.582 UTC] [D] VarInf Limit_Bat rt[2]set val[65] set rate[13.000000] value100[500] value-100[-500]
[2026-08-01 17:57:52.583 UTC] [D] VarInf Limit_Bat rt[2]set val[55] set rate[11.000000] value100[500] value-100[-500]
[2026-08-01 17:57:52.602 UTC] [D] 485AcReq <C3:01> PutOStream [6][0f000001000000090110278e0001020037]
[2026-08-01 17:57:52.603 UTC] [D] 485AcReq <C3:02> PutOStream [6][0f000001000000090110278e0001020037]
[2026-08-01 17:57:52.604 UTC] [D] 485AcReq <C3:03> PutOStream [6][0f000001000000090110278e0001020041]
[2026-08-01 17:57:52.605 UTC] [D] 485AcReq <C3:04> PutOStream [6][0f000001000000090110278e0001020037]
[2026-08-01 17:57:52.655 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:57:52.655 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:57:52.755 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:57:52.755 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:57:52.764 UTC] [V] 485DevCtl <C3:01> AnalyzeResponseData proc restart cnt:17952 UPRstat:0
[2026-08-01 17:57:52.766 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:57:52.766 UTC] [D] 485DevCtl <C3:01> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:57:52.766 UTC] [D] 485DevCtl <C3:01> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:57:52.767 UTC] [V] 485DevCtl <C3:01> device_type:Battery
[2026-08-01 17:57:52.769 UTC] [V] 485DevCtl <C3:02> AnalyzeResponseData proc restart cnt:17952 UPRstat:0
[2026-08-01 17:57:52.795 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:57:52.795 UTC] [D] 485DevCtl <C3:02> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:57:52.795 UTC] [D] 485DevCtl <C3:02> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:57:52.795 UTC] [V] 485DevCtl <C3:02> device_type:Battery
[2026-08-01 17:57:52.808 UTC] [V] 485DevCtl <C3:03> AnalyzeResponseData proc restart cnt:17952 UPRstat:0
[2026-08-01 17:57:52.809 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:57:52.809 UTC] [D] 485DevCtl <C3:03> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:57:52.810 UTC] [D] 485DevCtl <C3:03> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:57:52.810 UTC] [V] 485DevCtl <C3:03> device_type:Battery
[2026-08-01 17:57:52.810 UTC] [V] 485DevCtl <C3:04> AnalyzeResponseData proc restart cnt:17952 UPRstat:0
[2026-08-01 17:57:52.839 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:57:52.850 UTC] [D] 485DevCtl <C3:04> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:57:52.852 UTC] [D] 485DevCtl <C3:04> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:57:52.853 UTC] [V] 485DevCtl <C3:04> device_type:Battery
[2026-08-01 17:57:52.854 UTC] [V] 485ChCtl <C3> set rt:0
[2026-08-01 17:57:52.855 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:57:52.856 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:57:52.955 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:57:52.955 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:57:52.979 UTC] [V] Res no response condition. set normal condition.
[2026-08-01 17:57:52.981 UTC] [D] 485DevCtl <C2:02> RcvDat status[2] len[77] [0204480000c80c0000126d000000000000000000000000000000000000000000000000000000000000000000000000ffffffffffffffffffffffff00000000000000000000000000001400ca22]
[2026-08-01 17:57:52.981 UTC] [D] 485DevCtl <C2:02> ResCnd OperationId [1] IsNormal[1] 
[2026-08-01 17:57:52.981 UTC] [V] 485DevCtl <C2:02> [01][115202][0.000000][1][kWh]
[2026-08-01 17:57:52.981 UTC] [V] SummDat SetVrmValue dev_id:8 val:0.000000 sc:1
[2026-08-01 17:57:52.982 UTC] [V] OCMgr SetMeterValue PhId:0202, branchNo:01, valueId:115202, value:0.000000, scaleFactor:1, devId:8
[2026-08-01 17:57:52.989 UTC] [V] 485DevCtl <C2:02> [01][113202][51212.000000][0][kWh]
[2026-08-01 17:57:52.991 UTC] [V] SummDat SetVrmValue dev_id:8 val:51212.000000 sc:0
[2026-08-01 17:57:52.998 UTC] [V] OCMgr SetMeterValue PhId:0202, branchNo:01, valueId:113202, value:51212.000000, scaleFactor:0, devId:8
[2026-08-01 17:57:53.002 UTC] [V] 485DevCtl <C2:02> [01][121005][0.000000][1][℃]
[2026-08-01 17:57:53.005 UTC] [V] SummDat SetVrmValue dev_id:8 val:0.000000 sc:3
[2026-08-01 17:57:53.005 UTC] [V] OCMgr SetMeterValue PhId:0202, branchNo:01, valueId:121005, value:0.000000, scaleFactor:1, devId:8
[2026-08-01 17:57:53.006 UTC] [V] 485DevCtl <C2:02> [01][101100][0.000000][1][V]
[2026-08-01 17:57:53.006 UTC] [V] SummDat SetVrmValue dev_id:8 val:0.000000 sc:3
[2026-08-01 17:57:53.006 UTC] [V] OCMgr SetMeterValue PhId:0202, branchNo:01, valueId:101100, value:0.000000, scaleFactor:1, devId:8
[2026-08-01 17:57:53.013 UTC] [V] OFSCtrl [/var/local/solajithome/function/output_fluctuation_suppression/batt_data] write success.
[2026-08-01 17:57:53.022 UTC] [V] 485DevCtl <C2:02> [01][101101][0.000000][1][A]
[2026-08-01 17:57:53.025 UTC] [V] SummDat SetVrmValue dev_id:8 val:0.000000 sc:3
[2026-08-01 17:57:53.030 UTC] [V] OCMgr SetMeterValue PhId:0202, branchNo:01, valueId:101101, value:0.000000, scaleFactor:1, devId:8
[2026-08-01 17:57:53.034 UTC] [V] 485DevCtl <C2:02> [02][101100][0.000000][1][V]
[2026-08-01 17:57:53.035 UTC] [V] SummDat SetVrmValue dev_id:8 val:0.000000 sc:3
[2026-08-01 17:57:53.042 UTC] [V] OCMgr SetMeterValue PhId:0202, branchNo:02, valueId:101100, value:0.000000, scaleFactor:1, devId:8
[2026-08-01 17:57:53.042 UTC] [V] 485DevCtl <C2:02> [02][101101][0.000000][1][A]
[2026-08-01 17:57:53.043 UTC] [V] SummDat SetVrmValue dev_id:8 val:0.000000 sc:3
[2026-08-01 17:57:53.043 UTC] [V] OCMgr SetMeterValue PhId:0202, branchNo:02, valueId:101101, value:0.000000, scaleFactor:1, devId:8
[2026-08-01 17:57:53.043 UTC] [V] 485DevCtl <C2:02> [03][101100][0.000000][1][V]
[2026-08-01 17:57:53.043 UTC] [V] SummDat SetVrmValue dev_id:8 val:0.000000 sc:3
[2026-08-01 17:57:53.047 UTC] [V] OCMgr SetMeterValue PhId:0202, branchNo:03, valueId:101100, value:0.000000, scaleFactor:1, devId:8
[2026-08-01 17:57:53.053 UTC] [V] 485DevCtl <C2:02> [03][101101][0.000000][1][A]
[2026-08-01 17:57:53.055 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:57:53.055 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:57:53.056 UTC] [V] SummDat SetVrmValue dev_id:8 val:0.000000 sc:3
[2026-08-01 17:57:53.063 UTC] [V] OCMgr SetMeterValue PhId:0202, branchNo:03, valueId:101101, value:0.000000, scaleFactor:1, devId:8
[2026-08-01 17:57:53.069 UTC] [V] 485DevCtl <C2:02> [01][101102][0.000000][0][W]
[2026-08-01 17:57:53.072 UTC] [V] SummDat SetVrmValue dev_id:8 val:0.000000 sc:3
[2026-08-01 17:57:53.077 UTC] [V] OCMgr SetMeterValue PhId:0202, branchNo:01, valueId:101102, value:0.000000, scaleFactor:0, devId:8
[2026-08-01 17:57:53.082 UTC] [V] 485DevCtl <C2:02> [01][111200][0.000000][1][V]
[2026-08-01 17:57:53.086 UTC] [V] SummDat SetVrmValue dev_id:8 val:0.000000 sc:3
[2026-08-01 17:57:53.086 UTC] [V] OCMgr SetMeterValue PhId:0202, branchNo:01, valueId:111200, value:0.000000, scaleFactor:1, devId:8
[2026-08-01 17:57:53.087 UTC] [V] 485DevCtl <C2:02> [02][111200][0.000000][1][V]
[2026-08-01 17:57:53.087 UTC] [V] SummDat SetVrmValue dev_id:8 val:0.000000 sc:3
[2026-08-01 17:57:53.097 UTC] [V] OCMgr SetMeterValue PhId:0202, branchNo:02, valueId:111200, value:0.000000, scaleFactor:1, devId:8
[2026-08-01 17:57:53.100 UTC] [V] 485DevCtl <C2:02> [03][111200][0.000000][1][V]
[2026-08-01 17:57:53.103 UTC] [V] SummDat SetVrmValue dev_id:8 val:0.000000 sc:3
[2026-08-01 17:57:53.109 UTC] [V] OCMgr SetMeterValue PhId:0202, branchNo:03, valueId:111200, value:0.000000, scaleFactor:1, devId:8
[2026-08-01 17:57:53.118 UTC] [V] 485DevCtl <C2:02> [01][111201][0.000000][1][A]
[2026-08-01 17:57:53.124 UTC] [V] SummDat SetVrmValue dev_id:8 val:0.000000 sc:3
[2026-08-01 17:57:53.126 UTC] [V] OCMgr SetMeterValue PhId:0202, branchNo:01, valueId:111201, value:0.000000, scaleFactor:1, devId:8
[2026-08-01 17:57:53.127 UTC] [V] 485DevCtl <C2:02> [02][111201][0.000000][1][A]
[2026-08-01 17:57:53.128 UTC] [V] SummDat SetVrmValue dev_id:8 val:0.000000 sc:3
[2026-08-01 17:57:53.130 UTC] [V] OCMgr SetMeterValue PhId:0202, branchNo:02, valueId:111201, value:0.000000, scaleFactor:1, devId:8
[2026-08-01 17:57:53.132 UTC] [V] 485DevCtl <C2:02> [03][111201][0.000000][1][A]
[2026-08-01 17:57:53.134 UTC] [V] SummDat SetVrmValue dev_id:8 val:0.000000 sc:3
[2026-08-01 17:57:53.139 UTC] [V] OCMgr SetMeterValue PhId:0202, branchNo:03, valueId:111201, value:0.000000, scaleFactor:1, devId:8
[2026-08-01 17:57:53.141 UTC] [V] 485DevCtl <C2:02> [01][111202][0.000000][0][W]
[2026-08-01 17:57:53.143 UTC] [V] SummDat SetVrmValue dev_id:8 val:0.000000 sc:3
[2026-08-01 17:57:53.148 UTC] [V] OCMgr SetMeterValue PhId:0202, branchNo:01, valueId:111202, value:0.000000, scaleFactor:0, devId:8
[2026-08-01 17:57:53.151 UTC] [V] 485DevCtl <C2:02> [01][111203][0.000000][0][var]
[2026-08-01 17:57:53.152 UTC] [V] SummDat SetVrmValue dev_id:8 val:0.000000 sc:3
[2026-08-01 17:57:53.155 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:57:53.155 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:57:53.157 UTC] [V] OCMgr SetMeterValue PhId:0202, branchNo:01, valueId:111203, value:0.000000, scaleFactor:0, devId:8
[2026-08-01 17:57:53.164 UTC] [V] 485DevCtl <C2:02> [01][121007][0.000000][3][]
[2026-08-01 17:57:53.165 UTC] [V] SummDat SetVrmValue dev_id:8 val:0.000000 sc:3
[2026-08-01 17:57:53.166 UTC] [V] OCMgr SetMeterValue PhId:0202, branchNo:01, valueId:121007, value:0.000000, scaleFactor:3, devId:8
[2026-08-01 17:57:53.167 UTC] [V] 485DevCtl <C2:02> [01][131006][0.000000][1][Hz]
[2026-08-01 17:57:53.167 UTC] [V] SummDat SetVrmValue dev_id:8 val:0.000000 sc:3
[2026-08-01 17:57:53.171 UTC] [V] OCMgr SetMeterValue PhId:0202, branchNo:01, valueId:131006, value:0.000000, scaleFactor:1, devId:8
[2026-08-01 17:57:53.176 UTC] [V] 485DevCtl <C2:02> [01][114202][51212.000000][0][kWh]
[2026-08-01 17:57:53.177 UTC] [V] SummDat SetVrmValue dev_id:8 val:51212000.000000 sc:3
[2026-08-01 17:57:53.183 UTC] [V] OCMgr SetMeterValue PhId:0202, branchNo:01, valueId:114202, value:51212.000000, scaleFactor:0, devId:8
[2026-08-01 17:57:53.187 UTC] [V] 485DevCtl <C2:02> device_type:PV-PCS
[2026-08-01 17:57:53.196 UTC] [V] 485DevCtl <C2:02> set2 StatusCode[010100] DeviceName[] DeviceNumber[]
[2026-08-01 17:57:53.203 UTC] [V] 485ChCtl <C2> set rt:0
[2026-08-01 17:57:53.255 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:57:53.255 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:57:53.264 UTC] [V] 485ChCtl <C2> StartDeviceCommunicationForOutputFluctuationSuppressionControlBroadcast 4 cnt:179475, monitor_cnt:67, bc_elapsed:179475, min:10, max:40
[2026-08-01 17:57:53.264 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :1
[2026-08-01 17:57:53.265 UTC] [V] 485ChCtl <C2> send request:Sungrow08
[2026-08-01 17:57:53.266 UTC] [D] 485AcReq <C2:03> PutOStream [1][08000304138a0024d49d]
[2026-08-01 17:57:53.355 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:57:53.356 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:57:53.455 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:57:53.455 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:57:53.555 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:57:53.555 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:57:53.555 UTC] [V] OFSCtrl Control charge discharge proc start.
[2026-08-01 17:57:53.556 UTC] [V] OFSCtrl CHG 20 p_th(t):21303.750000 = p_th_old_:21293.850000 + lev_cd_:0.100000 * (total_pcs_capacity_:297000.000000 * cof_spec_:2.000000 / 60 * (time_threshold_renew:10.000000 * 10)), min:-2062.500000, max:407900.000000
[2026-08-01 17:57:53.556 UTC] [V] OFSCtrl CHG 21 batt_w:21979.465079 = old:21956.381579 +  kp:0.550000 * e:41.250000 + ki:0.000000 * sume:-11876.699857 + kd:0.040000 * (e:41.250000 - e1:31.350000)
[2026-08-01 17:57:53.557 UTC] [V] OFSCtrl CHG 21 battery threshold min:20000.000000 <= bat:21979.465079 <= max:196000.000000, adjust charge:0.000000, discharge:1000.000000
[2026-08-01 17:57:53.557 UTC] [V] OFSCtrl CHG 29 q:54.000000, mod(round):4.000000
[2026-08-01 17:57:53.557 UTC] [V] OFSCtrl discharge bat_w[0303]:6500.000000 += adjust:1000.000000
[2026-08-01 17:57:53.557 UTC] [D] OFSCtrl battery ctrl val:11.000000
[2026-08-01 17:57:53.559 UTC] [V] 485ChCtl <C3> battery limit on [55.000000,55.000000,65.000000,55.000000,] request.
[2026-08-01 17:57:53.563 UTC] [V] OFSCtrl Control charge discharge proc:01->02->BATT_CHK->03->04->05->06->10->12->13->15->16->17->20->21->22->23->24->25->27->23->24->25->27->23->24->25->27->23->24->25->27->28->29->30->31->32->30->31->32->30->31->32->30->31->32->33->34
[2026-08-01 17:57:53.579 UTC] [V] 485ChCtl <C3> battery send request.1
[2026-08-01 17:57:53.579 UTC] [D] VarInf Limit_Bat rt[2]set val[55] set rate[11.000000] value100[500] value-100[-500]
[2026-08-01 17:57:53.580 UTC] [D] VarInf Limit_Bat rt[2]set val[55] set rate[11.000000] value100[500] value-100[-500]
[2026-08-01 17:57:53.582 UTC] [D] VarInf Limit_Bat rt[2]set val[65] set rate[13.000000] value100[500] value-100[-500]
[2026-08-01 17:57:53.585 UTC] [D] VarInf Limit_Bat rt[2]set val[55] set rate[11.000000] value100[500] value-100[-500]
[2026-08-01 17:57:53.602 UTC] [D] 485AcReq <C3:01> PutOStream [6][0f000001000000090110278e0001020037]
[2026-08-01 17:57:53.603 UTC] [D] 485AcReq <C3:02> PutOStream [6][0f000001000000090110278e0001020037]
[2026-08-01 17:57:53.604 UTC] [D] 485AcReq <C3:03> PutOStream [6][0f000001000000090110278e0001020041]
[2026-08-01 17:57:53.604 UTC] [D] 485AcReq <C3:04> PutOStream [6][0f000001000000090110278e0001020037]
[2026-08-01 17:57:53.655 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:57:53.656 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:57:53.669 UTC] [V] Res no response condition. set normal condition.
[2026-08-01 17:57:53.672 UTC] [D] 485DevCtl <C2:03> RcvDat status[2] len[77] [0304480000000000000000000000000000000000000000000000000000000000000000000000000000000000000000ffffffffffffffffffffffff00000000000000000000000000001400c07a]
[2026-08-01 17:57:53.672 UTC] [D] 485DevCtl <C2:03> ResCnd OperationId [1] IsNormal[1] 
[2026-08-01 17:57:53.672 UTC] [V] 485DevCtl <C2:03> [01][115202][0.000000][1][kWh]
[2026-08-01 17:57:53.672 UTC] [V] SummDat SetVrmValue dev_id:9 val:0.000000 sc:1
[2026-08-01 17:57:53.673 UTC] [V] OCMgr SetMeterValue PhId:0203, branchNo:01, valueId:115202, value:0.000000, scaleFactor:1, devId:9
[2026-08-01 17:57:53.673 UTC] [V] 485DevCtl <C2:03> [01][113202][0.000000][0][kWh]
[2026-08-01 17:57:53.673 UTC] [V] SummDat SetVrmValue dev_id:9 val:0.000000 sc:0
[2026-08-01 17:57:53.673 UTC] [V] OCMgr SetMeterValue PhId:0203, branchNo:01, valueId:113202, value:0.000000, scaleFactor:0, devId:9
[2026-08-01 17:57:53.674 UTC] [V] 485DevCtl <C2:03> [01][121005][0.000000][1][℃]
[2026-08-01 17:57:53.674 UTC] [V] SummDat SetVrmValue dev_id:9 val:0.000000 sc:3
[2026-08-01 17:57:53.694 UTC] [V] OCMgr SetMeterValue PhId:0203, branchNo:01, valueId:121005, value:0.000000, scaleFactor:1, devId:9
[2026-08-01 17:57:53.696 UTC] [V] 485DevCtl <C2:03> [01][101100][0.000000][1][V]
[2026-08-01 17:57:53.696 UTC] [V] SummDat SetVrmValue dev_id:9 val:0.000000 sc:3
[2026-08-01 17:57:53.701 UTC] [V] OCMgr SetMeterValue PhId:0203, branchNo:01, valueId:101100, value:0.000000, scaleFactor:1, devId:9
[2026-08-01 17:57:53.707 UTC] [V] 485DevCtl <C2:03> [01][101101][0.000000][1][A]
[2026-08-01 17:57:53.710 UTC] [V] SummDat SetVrmValue dev_id:9 val:0.000000 sc:3
[2026-08-01 17:57:53.723 UTC] [V] OCMgr SetMeterValue PhId:0203, branchNo:01, valueId:101101, value:0.000000, scaleFactor:1, devId:9
[2026-08-01 17:57:53.725 UTC] [V] 485DevCtl <C2:03> [02][101100][0.000000][1][V]
[2026-08-01 17:57:53.727 UTC] [V] SummDat SetVrmValue dev_id:9 val:0.000000 sc:3
[2026-08-01 17:57:53.734 UTC] [V] OCMgr SetMeterValue PhId:0203, branchNo:02, valueId:101100, value:0.000000, scaleFactor:1, devId:9
[2026-08-01 17:57:53.743 UTC] [V] 485DevCtl <C2:03> [02][101101][0.000000][1][A]
[2026-08-01 17:57:53.743 UTC] [V] SummDat SetVrmValue dev_id:9 val:0.000000 sc:3
[2026-08-01 17:57:53.743 UTC] [V] OCMgr SetMeterValue PhId:0203, branchNo:02, valueId:101101, value:0.000000, scaleFactor:1, devId:9
[2026-08-01 17:57:53.749 UTC] [V] 485DevCtl <C2:03> [03][101100][0.000000][1][V]
[2026-08-01 17:57:53.751 UTC] [V] SummDat SetVrmValue dev_id:9 val:0.000000 sc:3
[2026-08-01 17:57:53.755 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:57:53.755 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:57:53.757 UTC] [V] OCMgr SetMeterValue PhId:0203, branchNo:03, valueId:101100, value:0.000000, scaleFactor:1, devId:9
[2026-08-01 17:57:53.761 UTC] [V] 485DevCtl <C2:03> [03][101101][0.000000][1][A]
[2026-08-01 17:57:53.763 UTC] [V] SummDat SetVrmValue dev_id:9 val:0.000000 sc:3
[2026-08-01 17:57:53.769 UTC] [V] OCMgr SetMeterValue PhId:0203, branchNo:03, valueId:101101, value:0.000000, scaleFactor:1, devId:9
[2026-08-01 17:57:53.774 UTC] [V] 485DevCtl <C2:03> [01][101102][0.000000][0][W]
[2026-08-01 17:57:53.776 UTC] [V] SummDat SetVrmValue dev_id:9 val:0.000000 sc:3
[2026-08-01 17:57:53.778 UTC] [V] OCMgr SetMeterValue PhId:0203, branchNo:01, valueId:101102, value:0.000000, scaleFactor:0, devId:9
[2026-08-01 17:57:53.779 UTC] [V] 485DevCtl <C2:03> [01][111200][0.000000][1][V]
[2026-08-01 17:57:53.779 UTC] [V] SummDat SetVrmValue dev_id:9 val:0.000000 sc:3
[2026-08-01 17:57:53.779 UTC] [V] OCMgr SetMeterValue PhId:0203, branchNo:01, valueId:111200, value:0.000000, scaleFactor:1, devId:9
[2026-08-01 17:57:53.779 UTC] [V] 485DevCtl <C2:03> [02][111200][0.000000][1][V]
[2026-08-01 17:57:53.780 UTC] [V] SummDat SetVrmValue dev_id:9 val:0.000000 sc:3
[2026-08-01 17:57:53.780 UTC] [V] OCMgr SetMeterValue PhId:0203, branchNo:02, valueId:111200, value:0.000000, scaleFactor:1, devId:9
[2026-08-01 17:57:53.780 UTC] [V] 485DevCtl <C2:03> [03][111200][0.000000][1][V]
[2026-08-01 17:57:53.780 UTC] [V] SummDat SetVrmValue dev_id:9 val:0.000000 sc:3
[2026-08-01 17:57:53.780 UTC] [V] OCMgr SetMeterValue PhId:0203, branchNo:03, valueId:111200, value:0.000000, scaleFactor:1, devId:9
[2026-08-01 17:57:53.781 UTC] [V] 485DevCtl <C2:03> [01][111201][0.000000][1][A]
[2026-08-01 17:57:53.781 UTC] [V] SummDat SetVrmValue dev_id:9 val:0.000000 sc:3
[2026-08-01 17:57:53.781 UTC] [V] OCMgr SetMeterValue PhId:0203, branchNo:01, valueId:111201, value:0.000000, scaleFactor:1, devId:9
[2026-08-01 17:57:53.781 UTC] [V] 485DevCtl <C2:03> [02][111201][0.000000][1][A]
[2026-08-01 17:57:53.781 UTC] [V] SummDat SetVrmValue dev_id:9 val:0.000000 sc:3
[2026-08-01 17:57:53.782 UTC] [V] OCMgr SetMeterValue PhId:0203, branchNo:02, valueId:111201, value:0.000000, scaleFactor:1, devId:9
[2026-08-01 17:57:53.784 UTC] [V] 485DevCtl <C3:01> AnalyzeResponseData proc restart cnt:17953 UPRstat:0
[2026-08-01 17:57:53.786 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:57:53.786 UTC] [D] 485DevCtl <C3:01> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:57:53.786 UTC] [D] 485DevCtl <C3:01> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:57:53.787 UTC] [V] 485DevCtl <C3:01> device_type:Battery
[2026-08-01 17:57:53.787 UTC] [V] 485DevCtl <C3:02> AnalyzeResponseData proc restart cnt:17953 UPRstat:0
[2026-08-01 17:57:53.802 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:57:53.808 UTC] [D] 485DevCtl <C3:02> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:57:53.809 UTC] [D] 485DevCtl <C3:02> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:57:53.813 UTC] [V] 485DevCtl <C3:02> device_type:Battery
[2026-08-01 17:57:53.815 UTC] [V] 485DevCtl <C3:03> AnalyzeResponseData proc restart cnt:17953 UPRstat:0
[2026-08-01 17:57:53.816 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:57:53.817 UTC] [D] 485DevCtl <C3:03> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:57:53.817 UTC] [D] 485DevCtl <C3:03> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:57:53.826 UTC] [V] 485DevCtl <C2:03> [03][111201][0.000000][1][A]
[2026-08-01 17:57:53.827 UTC] [V] SummDat SetVrmValue dev_id:9 val:0.000000 sc:3
[2026-08-01 17:57:53.829 UTC] [V] OCMgr SetMeterValue PhId:0203, branchNo:03, valueId:111201, value:0.000000, scaleFactor:1, devId:9
[2026-08-01 17:57:53.833 UTC] [V] 485DevCtl <C2:03> [01][111202][0.000000][0][W]
[2026-08-01 17:57:53.835 UTC] [V] SummDat SetVrmValue dev_id:9 val:0.000000 sc:3
[2026-08-01 17:57:53.836 UTC] [V] 485DevCtl <C3:03> device_type:Battery
[2026-08-01 17:57:53.844 UTC] [V] 485DevCtl <C3:04> AnalyzeResponseData proc restart cnt:17953 UPRstat:0
[2026-08-01 17:57:53.844 UTC] [V] OCMgr SetMeterValue PhId:0203, branchNo:01, valueId:111202, value:0.000000, scaleFactor:0, devId:9
[2026-08-01 17:57:53.845 UTC] [V] 485DevCtl <C2:03> [01][111203][0.000000][0][var]
[2026-08-01 17:57:53.847 UTC] [V] SummDat SetVrmValue dev_id:9 val:0.000000 sc:3
[2026-08-01 17:57:53.855 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:57:53.855 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:57:53.855 UTC] [V] OCMgr SetMeterValue PhId:0203, branchNo:01, valueId:111203, value:0.000000, scaleFactor:0, devId:9
[2026-08-01 17:57:53.856 UTC] [V] 485DevCtl <C2:03> [01][121007][0.000000][3][]
[2026-08-01 17:57:53.856 UTC] [V] SummDat SetVrmValue dev_id:9 val:0.000000 sc:3
[2026-08-01 17:57:53.856 UTC] [V] OCMgr SetMeterValue PhId:0203, branchNo:01, valueId:121007, value:0.000000, scaleFactor:3, devId:9
[2026-08-01 17:57:53.857 UTC] [V] 485DevCtl <C2:03> [01][131006][0.000000][1][Hz]
[2026-08-01 17:57:53.866 UTC] [V] SummDat SetVrmValue dev_id:9 val:0.000000 sc:3
[2026-08-01 17:57:53.868 UTC] [V] OCMgr SetMeterValue PhId:0203, branchNo:01, valueId:131006, value:0.000000, scaleFactor:1, devId:9
[2026-08-01 17:57:53.868 UTC] [V] 485DevCtl <C2:03> [01][114202][0.000000][0][kWh]
[2026-08-01 17:57:53.869 UTC] [V] SummDat SetVrmValue dev_id:9 val:0.000000 sc:3
[2026-08-01 17:57:53.869 UTC] [V] OCMgr SetMeterValue PhId:0203, branchNo:01, valueId:114202, value:0.000000, scaleFactor:0, devId:9
[2026-08-01 17:57:53.869 UTC] [V] 485DevCtl <C2:03> device_type:PV-PCS
[2026-08-01 17:57:53.870 UTC] [V] 485DevCtl <C2:03> set2 StatusCode[010100] DeviceName[] DeviceNumber[]
[2026-08-01 17:57:53.870 UTC] [V] 485ChCtl <C2> set rt:0
[2026-08-01 17:57:53.872 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:57:53.873 UTC] [D] 485DevCtl <C3:04> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:57:53.873 UTC] [D] 485DevCtl <C3:04> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:57:53.873 UTC] [V] 485DevCtl <C3:04> device_type:Battery
[2026-08-01 17:57:53.873 UTC] [V] 485ChCtl <C3> set rt:0
[2026-08-01 17:57:53.955 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:57:53.955 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:57:53.964 UTC] [V] 485ChCtl <C2> StartDeviceCommunicationForOutputFluctuationSuppressionControlBroadcast 4 cnt:179482, monitor_cnt:74, bc_elapsed:179482, min:10, max:40
[2026-08-01 17:57:53.965 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :2
[2026-08-01 17:57:53.965 UTC] [V] 485ChCtl <C2> send request:Sungrow08
[2026-08-01 17:57:53.966 UTC] [D] 485AcReq <C2:04> PutOStream [2][0800040413d80002f521]
[2026-08-01 17:57:54.013 UTC] [V] OFSCtrl [/var/local/solajithome/function/output_fluctuation_suppression/batt_data] write success.
[2026-08-01 17:57:54.055 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:57:54.056 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:57:54.155 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:57:54.155 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:57:54.255 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:57:54.255 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:57:54.295 UTC] [D] 485DevCtl <C2:04> RcvDat status[2] len[9] [04040400100000af41]
[2026-08-01 17:57:54.295 UTC] [D] 485DevCtl <C2:04> ResCnd OperationId [2] IsNormal[0]  ConditionType [lggrdev:Error] Action[4]
[2026-08-01 17:57:54.296 UTC] [V] 485DevCtl <C2:04> device_type:PV-PCS
[2026-08-01 17:57:54.296 UTC] [V] 485DevCtl <C2:04> ExecuteAction name:RestartCounter value0
[2026-08-01 17:57:54.296 UTC] [V] 485DevCtl <C2:04> ExecuteAction set start cnt:0
[2026-08-01 17:57:54.297 UTC] [V] 485ChCtl <C2> set rt:0
[2026-08-01 17:57:54.355 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:57:54.355 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:57:54.364 UTC] [V] 485ChCtl <C2> StartDeviceCommunicationForOutputFluctuationSuppressionControlBroadcast 4 cnt:179486, monitor_cnt:78, bc_elapsed:179486, min:10, max:40
[2026-08-01 17:57:54.364 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :9
[2026-08-01 17:57:54.365 UTC] [V] 485ChCtl <C2> send request:Sungrow08
[2026-08-01 17:57:54.365 UTC] [D] 485AcReq <C2:05> PutOStream [9][0800050413fa00179535]
[2026-08-01 17:57:54.455 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:57:54.455 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:57:54.556 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:57:54.556 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:57:54.556 UTC] [V] OFSCtrl Control charge discharge proc start.
[2026-08-01 17:57:54.556 UTC] [V] OFSCtrl CHG 20 p_th(t):21313.650000 = p_th_old_:21303.750000 + lev_cd_:0.100000 * (total_pcs_capacity_:297000.000000 * cof_spec_:2.000000 / 60 * (time_threshold_renew:10.000000 * 10)), min:-2062.500000, max:407900.000000
[2026-08-01 17:57:54.557 UTC] [V] OFSCtrl CHG 21 batt_w:22007.993579 = old:21979.465079 +  kp:0.550000 * e:51.150000 + ki:0.000000 * sume:-11825.549857 + kd:0.040000 * (e:51.150000 - e1:41.250000)
[2026-08-01 17:57:54.557 UTC] [V] OFSCtrl CHG 21 battery threshold min:20000.000000 <= bat:22007.993579 <= max:196000.000000, adjust charge:0.000000, discharge:1000.000000
[2026-08-01 17:57:54.558 UTC] [V] OFSCtrl CHG 29 q:55.000000, mod(round):0.000000
[2026-08-01 17:57:54.558 UTC] [V] OFSCtrl discharge bat_w[0303]:6500.000000 += adjust:1000.000000
[2026-08-01 17:57:54.558 UTC] [D] OFSCtrl battery ctrl val:11.000000
[2026-08-01 17:57:54.558 UTC] [V] 485ChCtl <C3> battery limit on [55.000000,55.000000,65.000000,55.000000,] request.
[2026-08-01 17:57:54.558 UTC] [V] OFSCtrl Control charge discharge proc:01->02->BATT_CHK->03->04->05->06->10->12->13->15->16->17->20->21->22->23->24->25->27->23->24->25->27->23->24->25->27->23->24->25->27->28->29->30->31->32->30->31->32->30->31->32->30->31->32->33->34
[2026-08-01 17:57:54.578 UTC] [V] 485ChCtl <C3> battery send request.1
[2026-08-01 17:57:54.579 UTC] [D] VarInf Limit_Bat rt[2]set val[55] set rate[11.000000] value100[500] value-100[-500]
[2026-08-01 17:57:54.580 UTC] [D] VarInf Limit_Bat rt[2]set val[55] set rate[11.000000] value100[500] value-100[-500]
[2026-08-01 17:57:54.581 UTC] [D] VarInf Limit_Bat rt[2]set val[65] set rate[13.000000] value100[500] value-100[-500]
[2026-08-01 17:57:54.595 UTC] [D] VarInf Limit_Bat rt[2]set val[55] set rate[11.000000] value100[500] value-100[-500]
[2026-08-01 17:57:54.609 UTC] [D] 485AcReq <C3:01> PutOStream [6][0f000001000000090110278e0001020037]
[2026-08-01 17:57:54.610 UTC] [D] 485AcReq <C3:02> PutOStream [6][0f000001000000090110278e0001020037]
[2026-08-01 17:57:54.610 UTC] [D] 485AcReq <C3:03> PutOStream [6][0f000001000000090110278e0001020041]
[2026-08-01 17:57:54.611 UTC] [D] 485AcReq <C3:04> PutOStream [6][0f000001000000090110278e0001020037]
[2026-08-01 17:57:54.655 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:57:54.655 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:57:54.741 UTC] [V] Res no response condition. set normal condition.
[2026-08-01 17:57:54.743 UTC] [D] 485DevCtl <C2:05> RcvDat status[2] len[51] [05042e000000000000000000000000ffffffffffffffff03e8ffffffff081e0000ffffffffffffffffffffffffffffffff01ea]
[2026-08-01 17:57:54.743 UTC] [D] 485DevCtl <C2:05> ResCnd OperationId [9] IsNormal[1] 
[2026-08-01 17:57:54.744 UTC] [V] 485DevCtl <C2:05> [04][101100][0.000000][1][V]
[2026-08-01 17:57:54.745 UTC] [V] SummDat SetVrmValue dev_id:11 val:0.000000 sc:3
[2026-08-01 17:57:54.750 UTC] [V] OCMgr SetMeterValue PhId:0205, branchNo:04, valueId:101100, value:0.000000, scaleFactor:1, devId:11
[2026-08-01 17:57:54.756 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:57:54.756 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:57:54.759 UTC] [V] 485DevCtl <C2:05> [04][101101][0.000000][1][A]
[2026-08-01 17:57:54.760 UTC] [V] SummDat SetVrmValue dev_id:11 val:0.000000 sc:3
[2026-08-01 17:57:54.769 UTC] [V] OCMgr SetMeterValue PhId:0205, branchNo:04, valueId:101101, value:0.000000, scaleFactor:1, devId:11
[2026-08-01 17:57:54.777 UTC] [V] 485DevCtl <C2:05> [05][101100][0.000000][1][V]
[2026-08-01 17:57:54.777 UTC] [V] SummDat SetVrmValue dev_id:11 val:0.000000 sc:3
[2026-08-01 17:57:54.777 UTC] [V] OCMgr SetMeterValue PhId:0205, branchNo:05, valueId:101100, value:0.000000, scaleFactor:1, devId:11
[2026-08-01 17:57:54.784 UTC] [V] 485DevCtl <C3:01> AnalyzeResponseData proc restart cnt:17954 UPRstat:0
[2026-08-01 17:57:54.786 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:57:54.787 UTC] [D] 485DevCtl <C3:01> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:57:54.787 UTC] [D] 485DevCtl <C3:01> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:57:54.787 UTC] [V] 485DevCtl <C3:01> device_type:Battery
[2026-08-01 17:57:54.788 UTC] [V] 485DevCtl <C3:02> AnalyzeResponseData proc restart cnt:17954 UPRstat:0
[2026-08-01 17:57:54.795 UTC] [V] 485DevCtl <C2:05> [05][101101][0.000000][1][A]
[2026-08-01 17:57:54.798 UTC] [V] SummDat SetVrmValue dev_id:11 val:0.000000 sc:3
[2026-08-01 17:57:54.798 UTC] [V] OCMgr SetMeterValue PhId:0205, branchNo:05, valueId:101101, value:0.000000, scaleFactor:1, devId:11
[2026-08-01 17:57:54.798 UTC] [V] 485DevCtl <C2:05> [06][101100][0.000000][1][V]
[2026-08-01 17:57:54.800 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:57:54.801 UTC] [D] 485DevCtl <C3:02> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:57:54.801 UTC] [D] 485DevCtl <C3:02> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:57:54.801 UTC] [V] 485DevCtl <C3:02> device_type:Battery
[2026-08-01 17:57:54.802 UTC] [V] 485DevCtl <C3:03> AnalyzeResponseData proc restart cnt:17954 UPRstat:0
[2026-08-01 17:57:54.807 UTC] [V] SummDat SetVrmValue dev_id:11 val:0.000000 sc:3
[2026-08-01 17:57:54.814 UTC] [V] OCMgr SetMeterValue PhId:0205, branchNo:06, valueId:101100, value:0.000000, scaleFactor:1, devId:11
[2026-08-01 17:57:54.818 UTC] [V] 485DevCtl <C2:05> [06][101101][0.000000][1][A]
[2026-08-01 17:57:54.818 UTC] [V] SummDat SetVrmValue dev_id:11 val:0.000000 sc:3
[2026-08-01 17:57:54.818 UTC] [V] OCMgr SetMeterValue PhId:0205, branchNo:06, valueId:101101, value:0.000000, scaleFactor:1, devId:11
[2026-08-01 17:57:54.828 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:57:54.829 UTC] [D] 485DevCtl <C3:03> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:57:54.829 UTC] [D] 485DevCtl <C3:03> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:57:54.829 UTC] [V] 485DevCtl <C3:03> device_type:Battery
[2026-08-01 17:57:54.838 UTC] [V] 485DevCtl <C2:05> device_type:PV-PCS
[2026-08-01 17:57:54.845 UTC] [V] 485ChCtl <C2> set rt:0
[2026-08-01 17:57:54.849 UTC] [V] 485DevCtl <C3:04> AnalyzeResponseData proc restart cnt:17954 UPRstat:0
[2026-08-01 17:57:54.855 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:57:54.855 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:57:54.864 UTC] [V] 485ChCtl <C2> StartDeviceCommunicationForOutputFluctuationSuppressionControlBroadcast 4 cnt:179491, monitor_cnt:83, bc_elapsed:179491, min:10, max:40
[2026-08-01 17:57:54.864 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :1
[2026-08-01 17:57:54.865 UTC] [V] 485ChCtl <C2> send request:Sungrow08
[2026-08-01 17:57:54.867 UTC] [D] 485AcReq <C2:06> PutOStream [1][08000604138a0024d4c8]
[2026-08-01 17:57:54.869 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:57:54.878 UTC] [D] 485DevCtl <C3:04> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:57:54.878 UTC] [D] 485DevCtl <C3:04> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:57:54.879 UTC] [V] 485DevCtl <C3:04> device_type:Battery
[2026-08-01 17:57:54.879 UTC] [V] 485ChCtl <C3> set rt:0
[2026-08-01 17:57:54.955 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:57:54.955 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:57:55.012 UTC] [V] OFSCtrl [/var/local/solajithome/function/output_fluctuation_suppression/batt_data] write success.
[2026-08-01 17:57:55.055 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:57:55.055 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:57:55.155 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:57:55.155 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:57:55.255 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:57:55.255 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:57:55.264 UTC] [V] Res no response condition. set normal condition.
[2026-08-01 17:57:55.266 UTC] [D] 485DevCtl <C2:06> RcvDat status[2] len[77] [0604480000c89700001270000000000000000000000000000000000000000000000000000000000000000000000000ffffffffffffffffffffffff0000000000000000000000000000140042af]
[2026-08-01 17:57:55.266 UTC] [D] 485DevCtl <C2:06> ResCnd OperationId [1] IsNormal[1] 
[2026-08-01 17:57:55.267 UTC] [V] 485DevCtl <C2:06> [01][115202][0.000000][1][kWh]
[2026-08-01 17:57:55.267 UTC] [V] SummDat SetVrmValue dev_id:12 val:0.000000 sc:1
[2026-08-01 17:57:55.267 UTC] [V] OCMgr SetMeterValue PhId:0206, branchNo:01, valueId:115202, value:0.000000, scaleFactor:1, devId:12
[2026-08-01 17:57:55.268 UTC] [V] 485DevCtl <C2:06> [01][113202][51351.000000][0][kWh]
[2026-08-01 17:57:55.268 UTC] [V] SummDat SetVrmValue dev_id:12 val:51351.000000 sc:0
[2026-08-01 17:57:55.268 UTC] [V] OCMgr SetMeterValue PhId:0206, branchNo:01, valueId:113202, value:51351.000000, scaleFactor:0, devId:12
[2026-08-01 17:57:55.268 UTC] [V] 485DevCtl <C2:06> [01][121005][0.000000][1][℃]
[2026-08-01 17:57:55.268 UTC] [V] SummDat SetVrmValue dev_id:12 val:0.000000 sc:3
[2026-08-01 17:57:55.269 UTC] [V] OCMgr SetMeterValue PhId:0206, branchNo:01, valueId:121005, value:0.000000, scaleFactor:1, devId:12
[2026-08-01 17:57:55.269 UTC] [V] 485DevCtl <C2:06> [01][101100][0.000000][1][V]
[2026-08-01 17:57:55.269 UTC] [V] SummDat SetVrmValue dev_id:12 val:0.000000 sc:3
[2026-08-01 17:57:55.269 UTC] [V] OCMgr SetMeterValue PhId:0206, branchNo:01, valueId:101100, value:0.000000, scaleFactor:1, devId:12
[2026-08-01 17:57:55.290 UTC] [V] 485DevCtl <C2:06> [01][101101][0.000000][1][A]
[2026-08-01 17:57:55.292 UTC] [V] SummDat SetVrmValue dev_id:12 val:0.000000 sc:3
[2026-08-01 17:57:55.298 UTC] [V] OCMgr SetMeterValue PhId:0206, branchNo:01, valueId:101101, value:0.000000, scaleFactor:1, devId:12
[2026-08-01 17:57:55.302 UTC] [V] 485DevCtl <C2:06> [02][101100][0.000000][1][V]
[2026-08-01 17:57:55.303 UTC] [V] SummDat SetVrmValue dev_id:12 val:0.000000 sc:3
[2026-08-01 17:57:55.308 UTC] [V] OCMgr SetMeterValue PhId:0206, branchNo:02, valueId:101100, value:0.000000, scaleFactor:1, devId:12
[2026-08-01 17:57:55.313 UTC] [V] 485DevCtl <C2:06> [02][101101][0.000000][1][A]
[2026-08-01 17:57:55.314 UTC] [V] SummDat SetVrmValue dev_id:12 val:0.000000 sc:3
[2026-08-01 17:57:55.318 UTC] [V] OCMgr SetMeterValue PhId:0206, branchNo:02, valueId:101101, value:0.000000, scaleFactor:1, devId:12
[2026-08-01 17:57:55.320 UTC] [V] 485DevCtl <C2:06> [03][101100][0.000000][1][V]
[2026-08-01 17:57:55.321 UTC] [V] SummDat SetVrmValue dev_id:12 val:0.000000 sc:3
[2026-08-01 17:57:55.325 UTC] [V] OCMgr SetMeterValue PhId:0206, branchNo:03, valueId:101100, value:0.000000, scaleFactor:1, devId:12
[2026-08-01 17:57:55.329 UTC] [V] 485DevCtl <C2:06> [03][101101][0.000000][1][A]
[2026-08-01 17:57:55.331 UTC] [V] SummDat SetVrmValue dev_id:12 val:0.000000 sc:3
[2026-08-01 17:57:55.334 UTC] [V] OCMgr SetMeterValue PhId:0206, branchNo:03, valueId:101101, value:0.000000, scaleFactor:1, devId:12
[2026-08-01 17:57:55.336 UTC] [V] 485DevCtl <C2:06> [01][101102][0.000000][0][W]
[2026-08-01 17:57:55.337 UTC] [V] SummDat SetVrmValue dev_id:12 val:0.000000 sc:3
[2026-08-01 17:57:55.341 UTC] [V] OCMgr SetMeterValue PhId:0206, branchNo:01, valueId:101102, value:0.000000, scaleFactor:0, devId:12
[2026-08-01 17:57:55.344 UTC] [V] 485DevCtl <C2:06> [01][111200][0.000000][1][V]
[2026-08-01 17:57:55.344 UTC] [V] SummDat SetVrmValue dev_id:12 val:0.000000 sc:3
[2026-08-01 17:57:55.345 UTC] [V] OCMgr SetMeterValue PhId:0206, branchNo:01, valueId:111200, value:0.000000, scaleFactor:1, devId:12
[2026-08-01 17:57:55.345 UTC] [V] 485DevCtl <C2:06> [02][111200][0.000000][1][V]
[2026-08-01 17:57:55.345 UTC] [V] SummDat SetVrmValue dev_id:12 val:0.000000 sc:3
[2026-08-01 17:57:55.350 UTC] [V] OCMgr SetMeterValue PhId:0206, branchNo:02, valueId:111200, value:0.000000, scaleFactor:1, devId:12
[2026-08-01 17:57:55.351 UTC] [V] 485DevCtl <C2:06> [03][111200][0.000000][1][V]
[2026-08-01 17:57:55.351 UTC] [V] SummDat SetVrmValue dev_id:12 val:0.000000 sc:3
[2026-08-01 17:57:55.354 UTC] [V] OCMgr SetMeterValue PhId:0206, branchNo:03, valueId:111200, value:0.000000, scaleFactor:1, devId:12
[2026-08-01 17:57:55.356 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:57:55.356 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:57:55.356 UTC] [V] 485DevCtl <C2:06> [01][111201][0.000000][1][A]
[2026-08-01 17:57:55.357 UTC] [V] SummDat SetVrmValue dev_id:12 val:0.000000 sc:3
[2026-08-01 17:57:55.362 UTC] [V] OCMgr SetMeterValue PhId:0206, branchNo:01, valueId:111201, value:0.000000, scaleFactor:1, devId:12
[2026-08-01 17:57:55.366 UTC] [V] 485DevCtl <C2:06> [02][111201][0.000000][1][A]
[2026-08-01 17:57:55.368 UTC] [V] SummDat SetVrmValue dev_id:12 val:0.000000 sc:3
[2026-08-01 17:57:55.372 UTC] [V] OCMgr SetMeterValue PhId:0206, branchNo:02, valueId:111201, value:0.000000, scaleFactor:1, devId:12
[2026-08-01 17:57:55.376 UTC] [V] 485DevCtl <C2:06> [03][111201][0.000000][1][A]
[2026-08-01 17:57:55.377 UTC] [V] SummDat SetVrmValue dev_id:12 val:0.000000 sc:3
[2026-08-01 17:57:55.381 UTC] [V] OCMgr SetMeterValue PhId:0206, branchNo:03, valueId:111201, value:0.000000, scaleFactor:1, devId:12
[2026-08-01 17:57:55.385 UTC] [V] 485DevCtl <C2:06> [01][111202][0.000000][0][W]
[2026-08-01 17:57:55.386 UTC] [V] SummDat SetVrmValue dev_id:12 val:0.000000 sc:3
[2026-08-01 17:57:55.389 UTC] [V] OCMgr SetMeterValue PhId:0206, branchNo:01, valueId:111202, value:0.000000, scaleFactor:0, devId:12
[2026-08-01 17:57:55.392 UTC] [V] 485DevCtl <C2:06> [01][111203][0.000000][0][var]
[2026-08-01 17:57:55.395 UTC] [V] SummDat SetVrmValue dev_id:12 val:0.000000 sc:3
[2026-08-01 17:57:55.399 UTC] [V] OCMgr SetMeterValue PhId:0206, branchNo:01, valueId:111203, value:0.000000, scaleFactor:0, devId:12
[2026-08-01 17:57:55.401 UTC] [V] 485DevCtl <C2:06> [01][121007][0.000000][3][]
[2026-08-01 17:57:55.403 UTC] [V] SummDat SetVrmValue dev_id:12 val:0.000000 sc:3
[2026-08-01 17:57:55.408 UTC] [V] OCMgr SetMeterValue PhId:0206, branchNo:01, valueId:121007, value:0.000000, scaleFactor:3, devId:12
[2026-08-01 17:57:55.411 UTC] [V] 485DevCtl <C2:06> [01][131006][0.000000][1][Hz]
[2026-08-01 17:57:55.412 UTC] [V] SummDat SetVrmValue dev_id:12 val:0.000000 sc:3
[2026-08-01 17:57:55.416 UTC] [V] OCMgr SetMeterValue PhId:0206, branchNo:01, valueId:131006, value:0.000000, scaleFactor:1, devId:12
[2026-08-01 17:57:55.417 UTC] [V] 485DevCtl <C2:06> [01][114202][51351.000000][0][kWh]
[2026-08-01 17:57:55.418 UTC] [V] SummDat SetVrmValue dev_id:12 val:51351000.000000 sc:3
[2026-08-01 17:57:55.418 UTC] [V] OCMgr SetMeterValue PhId:0206, branchNo:01, valueId:114202, value:51351.000000, scaleFactor:0, devId:12
[2026-08-01 17:57:55.418 UTC] [V] 485DevCtl <C2:06> device_type:PV-PCS
[2026-08-01 17:57:55.419 UTC] [V] 485DevCtl <C2:06> set2 StatusCode[010100] DeviceName[] DeviceNumber[]
[2026-08-01 17:57:55.419 UTC] [V] 485ChCtl <C2> set rt:0
[2026-08-01 17:57:55.428 UTC] [D] 485ChCtl <C2> monitoring dev All Send
[2026-08-01 17:57:55.455 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:57:55.456 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:57:55.555 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:57:55.555 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:57:55.556 UTC] [V] OFSCtrl Control charge discharge proc start.
[2026-08-01 17:57:55.556 UTC] [V] OFSCtrl CHG 20 p_th(t):21323.550000 = p_th_old_:21313.650000 + lev_cd_:0.100000 * (total_pcs_capacity_:297000.000000 * cof_spec_:2.000000 / 60 * (time_threshold_renew:10.000000 * 10)), min:-2062.500000, max:407900.000000
[2026-08-01 17:57:55.557 UTC] [V] OFSCtrl CHG 21 batt_w:22041.967079 = old:22007.993579 +  kp:0.550000 * e:61.050000 + ki:0.000000 * sume:-11764.499857 + kd:0.040000 * (e:61.050000 - e1:51.150000)
[2026-08-01 17:57:55.557 UTC] [V] OFSCtrl CHG 21 battery threshold min:20000.000000 <= bat:22041.967079 <= max:196000.000000, adjust charge:0.000000, discharge:1000.000000
[2026-08-01 17:57:55.557 UTC] [V] OFSCtrl CHG 29 q:55.000000, mod(round):0.000000
[2026-08-01 17:57:55.559 UTC] [V] OFSCtrl discharge bat_w[0303]:6500.000000 += adjust:1000.000000
[2026-08-01 17:57:55.559 UTC] [D] OFSCtrl battery ctrl val:11.000000
[2026-08-01 17:57:55.564 UTC] [V] 485ChCtl <C3> battery limit on [55.000000,55.000000,65.000000,55.000000,] request.
[2026-08-01 17:57:55.567 UTC] [V] OFSCtrl Control charge discharge proc:01->02->BATT_CHK->03->04->05->06->10->12->13->15->16->17->20->21->22->23->24->25->27->23->24->25->27->23->24->25->27->23->24->25->27->28->29->30->31->32->30->31->32->30->31->32->30->31->32->33->34
[2026-08-01 17:57:55.579 UTC] [V] 485ChCtl <C3> battery send request.1
[2026-08-01 17:57:55.580 UTC] [D] VarInf Limit_Bat rt[2]set val[55] set rate[11.000000] value100[500] value-100[-500]
[2026-08-01 17:57:55.581 UTC] [D] VarInf Limit_Bat rt[2]set val[55] set rate[11.000000] value100[500] value-100[-500]
[2026-08-01 17:57:55.582 UTC] [D] VarInf Limit_Bat rt[2]set val[65] set rate[13.000000] value100[500] value-100[-500]
[2026-08-01 17:57:55.609 UTC] [D] VarInf Limit_Bat rt[2]set val[55] set rate[11.000000] value100[500] value-100[-500]
[2026-08-01 17:57:55.619 UTC] [D] 485AcReq <C3:01> PutOStream [6][0f000001000000090110278e0001020037]
[2026-08-01 17:57:55.620 UTC] [D] 485AcReq <C3:02> PutOStream [6][0f000001000000090110278e0001020037]
[2026-08-01 17:57:55.621 UTC] [D] 485AcReq <C3:03> PutOStream [6][0f000001000000090110278e0001020041]
[2026-08-01 17:57:55.621 UTC] [D] 485AcReq <C3:04> PutOStream [6][0f000001000000090110278e0001020037]
[2026-08-01 17:57:55.655 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:57:55.655 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:57:55.755 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:57:55.755 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:57:55.756 UTC] [V] 485DevCtl <C1:01> device_type:Irr-Meter
[2026-08-01 17:57:55.757 UTC] [V] 485DevCtl <C1:01> device_type:Irr-Meter
[2026-08-01 17:57:55.757 UTC] [V] 485ChCtl <C1> fixed cycle Irr-Meter
[2026-08-01 17:57:55.757 UTC] [V] 485DevCtl <C1:01> Dev not PCS IsNeedToChangeOControlState
[2026-08-01 17:57:55.757 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :1
[2026-08-01 17:57:55.758 UTC] [V] 485ChCtl <C1> send request:Irr01
[2026-08-01 17:57:55.759 UTC] [D] 485AcReq <C1:01> PutOStream [1][080001040000000271cb]
[2026-08-01 17:57:55.794 UTC] [V] 485DevCtl <C3:01> AnalyzeResponseData proc restart cnt:17955 UPRstat:0
[2026-08-01 17:57:55.798 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:57:55.799 UTC] [D] 485DevCtl <C3:01> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:57:55.799 UTC] [D] 485DevCtl <C3:01> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:57:55.799 UTC] [V] 485DevCtl <C3:01> device_type:Battery
[2026-08-01 17:57:55.799 UTC] [V] 485DevCtl <C3:02> AnalyzeResponseData proc restart cnt:17955 UPRstat:0
[2026-08-01 17:57:55.801 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:57:55.801 UTC] [D] 485DevCtl <C3:02> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:57:55.801 UTC] [D] 485DevCtl <C3:02> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:57:55.801 UTC] [V] 485DevCtl <C3:02> device_type:Battery
[2026-08-01 17:57:55.802 UTC] [V] 485DevCtl <C3:03> AnalyzeResponseData proc restart cnt:17955 UPRstat:0
[2026-08-01 17:57:55.830 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:57:55.831 UTC] [D] 485DevCtl <C3:03> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:57:55.831 UTC] [D] 485DevCtl <C3:03> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:57:55.831 UTC] [V] 485DevCtl <C3:03> device_type:Battery
[2026-08-01 17:57:55.831 UTC] [V] 485DevCtl <C3:04> AnalyzeResponseData proc restart cnt:17955 UPRstat:0
[2026-08-01 17:57:55.855 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:57:55.855 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:57:55.863 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:57:55.878 UTC] [D] 485DevCtl <C3:04> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:57:55.878 UTC] [D] 485DevCtl <C3:04> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:57:55.878 UTC] [V] 485DevCtl <C3:04> device_type:Battery
[2026-08-01 17:57:55.884 UTC] [V] 485ChCtl <C3> set rt:0
[2026-08-01 17:57:55.955 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:57:55.955 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:57:56.012 UTC] [V] OFSCtrl [/var/local/solajithome/function/output_fluctuation_suppression/batt_data] write success.
[2026-08-01 17:57:56.055 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:57:56.056 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:57:56.093 UTC] [V] 485DevCtl <C1:01> AnalyzeResponseData proc restart cnt:17973 UPRstat:0
[2026-08-01 17:57:56.093 UTC] [V] Res no response condition. set normal condition.
[2026-08-01 17:57:56.094 UTC] [D] 485DevCtl <C1:01> RcvDat status[2] len[9] [010404000001fa7a57]
[2026-08-01 17:57:56.094 UTC] [D] 485DevCtl <C1:01> ResCnd OperationId [1] IsNormal[1] 
[2026-08-01 17:57:56.095 UTC] [V] OFSCtrl Rcv set flux_of_solar:0.000000
[2026-08-01 17:57:56.095 UTC] [V] 485DevCtl <C1:01> [01][401006][0.000000][1][W/m2]
[2026-08-01 17:57:56.095 UTC] [V] SummDat SetVrmValue dev_id:1 val:0.000000 sc:3
[2026-08-01 17:57:56.096 UTC] [V] OCMgr SetMeterValue PhId:0101, branchNo:01, valueId:401006, value:0.000000, scaleFactor:1, devId:1
[2026-08-01 17:57:56.096 UTC] [V] 485DevCtl <C1:01> [01][421005][256.000000][1][℃]
[2026-08-01 17:57:56.096 UTC] [V] SummDat SetVrmValue dev_id:1 val:25600.000000 sc:3
[2026-08-01 17:57:56.096 UTC] [V] OCMgr SetMeterValue PhId:0101, branchNo:01, valueId:421005, value:256.000000, scaleFactor:1, devId:1
[2026-08-01 17:57:56.097 UTC] [V] 485DevCtl <C1:01> device_type:Irr-Meter
[2026-08-01 17:57:56.097 UTC] [V] OFSCtrl Irr-Meter received.
[2026-08-01 17:57:56.097 UTC] [V] 485ChCtl <C1> set rt:0
[2026-08-01 17:57:56.108 UTC] [V] 485DevCtl <C1:01> device_type:Irr-Meter
[2026-08-01 17:57:56.155 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:57:56.155 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:57:56.156 UTC] [V] 485DevCtl <C1:04> device_type:CO-Meter
[2026-08-01 17:57:56.157 UTC] [V] 485DevCtl <C1:04> device_type:CO-Meter
[2026-08-01 17:57:56.157 UTC] [V] 485ChCtl <C1> fixed cycle CO-Meter
[2026-08-01 17:57:56.157 UTC] [V] 485DevCtl <C1:04> Dev not PCS IsNeedToChangeOControlState
[2026-08-01 17:57:56.157 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :1
[2026-08-01 17:57:56.158 UTC] [V] 485ChCtl <C1> send request:omron05
[2026-08-01 17:57:56.158 UTC] [D] 485AcReq <C1:04> PutOStream [1][0800040300030014b590]
[2026-08-01 17:57:56.255 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:57:56.255 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:57:56.355 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:57:56.355 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:57:56.379 UTC] [V] 485ChCtl <C3> StartDeviceCommunicationForOutputFluctuationSuppressionControlBroadcast 4 cnt:179506, monitor_cnt:50, bc_elapsed:179506, min:10, max:40
[2026-08-01 17:57:56.379 UTC] [V] OFSCtrl /var/local/solajithome/function/output_fluctuation_suppression/state is exist:0
[2026-08-01 17:57:56.379 UTC] [V] 485DevCtl <C3:01> Dev not PCS IsNeedToChangeOControlState
[2026-08-01 17:57:56.379 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :4
[2026-08-01 17:57:56.380 UTC] [V] 485ChCtl <C3> send request:Sungrow11
[2026-08-01 17:57:56.381 UTC] [D] 485AcReq <C3:01> PutOStream [4][0c00000100000006010427f0002f]
[2026-08-01 17:57:56.455 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:57:56.455 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:57:56.503 UTC] [V] 485DevCtl <C3:01> AnalyzeResponseData proc restart cnt:17955 UPRstat:0
[2026-08-01 17:57:56.517 UTC] [D] 485DevCtl <C3:01> RcvDat status[0] len[103] [00010000006101045e1e9d004800370ffa0fc11044004d004e004d003600000000000000000000000000000001000000ad458a00003e9f0000012c0000006700ab247300000001177103e701cc000000ab035800000e640000ec0b000100360000000000ad0000]
[2026-08-01 17:57:56.518 UTC] [D] 485DevCtl <C3:01> ResCnd OperationId [4] IsNormal[1]  ConditionType [lggrdev:Normal] Action[-1]
[2026-08-01 17:57:56.523 UTC] [V] 485DevCtl <C3:01> [05][753053][0.000000][0][]
[2026-08-01 17:57:56.523 UTC] [V] SummDat SetVrmValue dev_id:13 val:0.000000 sc:0
[2026-08-01 17:57:56.532 UTC] [V] OCMgr SetMeterValue PhId:0301, branchNo:05, valueId:753053, value:0.000000, scaleFactor:0, devId:13
[2026-08-01 17:57:56.537 UTC] [V] 485DevCtl <C3:01> [06][753053][0.000000][0][]
[2026-08-01 17:57:56.542 UTC] [V] SummDat SetVrmValue dev_id:13 val:0.000000 sc:0
[2026-08-01 17:57:56.545 UTC] [V] OCMgr SetMeterValue PhId:0301, branchNo:06, valueId:753053, value:0.000000, scaleFactor:0, devId:13
[2026-08-01 17:57:56.551 UTC] [V] 485DevCtl <C3:01> [07][753053][0.000000][0][]
[2026-08-01 17:57:56.551 UTC] [V] SummDat SetVrmValue dev_id:13 val:0.000000 sc:0
[2026-08-01 17:57:56.555 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:57:56.555 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:57:56.555 UTC] [V] OFSCtrl Control charge discharge proc start.
[2026-08-01 17:57:56.555 UTC] [V] OFSCtrl CHG 20 p_th(t):21333.450000 = p_th_old_:21323.550000 + lev_cd_:0.100000 * (total_pcs_capacity_:297000.000000 * cof_spec_:2.000000 / 60 * (time_threshold_renew:10.000000 * 10)), min:-2062.500000, max:407900.000000
[2026-08-01 17:57:56.556 UTC] [V] OFSCtrl CHG 21 batt_w:22081.385579 = old:22041.967079 +  kp:0.550000 * e:70.950000 + ki:0.000000 * sume:-11693.549857 + kd:0.040000 * (e:70.950000 - e1:61.050000)
[2026-08-01 17:57:56.556 UTC] [V] OFSCtrl CHG 21 battery threshold min:20000.000000 <= bat:22081.385579 <= max:196000.000000, adjust charge:0.000000, discharge:1000.000000
[2026-08-01 17:57:56.556 UTC] [V] OFSCtrl CHG 29 q:55.000000, mod(round):1.000000
[2026-08-01 17:57:56.556 UTC] [V] OFSCtrl discharge bat_w[0303]:6600.000000 += adjust:1000.000000
[2026-08-01 17:57:56.556 UTC] [D] OFSCtrl battery ctrl val:11.000000
[2026-08-01 17:57:56.557 UTC] [V] 485ChCtl <C3> battery limit on [55.000000,55.000000,66.000000,55.000000,] request.
[2026-08-01 17:57:56.557 UTC] [V] OFSCtrl Control charge discharge proc:01->02->BATT_CHK->03->04->05->06->10->12->13->15->16->17->20->21->22->23->24->25->27->23->24->25->27->23->24->25->27->23->24->25->27->28->29->30->31->32->30->31->32->30->31->32->30->31->32->33->34
[2026-08-01 17:57:56.562 UTC] [V] 485DevCtl <C1:04> AnalyzeResponseData proc restart cnt:17973 UPRstat:0
[2026-08-01 17:57:56.562 UTC] [V] Res no response condition. set normal condition.
[2026-08-01 17:57:56.564 UTC] [D] 485DevCtl <C1:04> RcvDat status[2] len[45] [0403280000f4b90000fbd80000e3fa000000640000025800034a470000086cffffbed0ffffff5a00233b027b2d]
[2026-08-01 17:57:56.565 UTC] [D] 485DevCtl <C1:04> ResCnd OperationId [1] IsNormal[1] 
[2026-08-01 17:57:56.565 UTC] [V] OFSCtrl Rcv set p_co:21560.000000, p_co_old:21520.000000
[2026-08-01 17:57:56.565 UTC] [V] 485DevCtl <C1:04> [01][601260][2156.000000][2][kW]
[2026-08-01 17:57:56.565 UTC] [V] SummDat SetVrmValue dev_id:4 val:21560.000000 sc:3
[2026-08-01 17:57:56.566 UTC] [V] OCMgr SetMeterValue PhId:0104, branchNo:01, valueId:601260, value:2156.000000, scaleFactor:2, devId:4
[2026-08-01 17:57:56.566 UTC] [V] 485DevCtl <C1:04> [01][603260][2308866.000000][1][kWh]
[2026-08-01 17:57:56.566 UTC] [V] SummDat SetVrmValue dev_id:4 val:2308866.000000 sc:1
[2026-08-01 17:57:56.566 UTC] [V] OCMgr SetMeterValue PhId:0104, branchNo:01, valueId:603260, value:2308866.000000, scaleFactor:1, devId:4
[2026-08-01 17:57:56.566 UTC] [V] 485DevCtl <C1:04> device_type:CO-Meter
[2026-08-01 17:57:56.567 UTC] [V] OFSCtrl km50 received.
[2026-08-01 17:57:56.567 UTC] [V] OFSCtrl omron05_local_date :2026/08/02 ? 2026/08/02
[2026-08-01 17:57:56.567 UTC] [V] OFSCtrl omron05_local_time :2026/08/02 02 ? 2026/08/02 02
[2026-08-01 17:57:56.569 UTC] [V] OCMgr SetMeterValue PhId:0301, branchNo:07, valueId:753053, value:0.000000, scaleFactor:0, devId:13
[2026-08-01 17:57:56.576 UTC] [V] 485DevCtl <C3:01> device_type:Battery
[2026-08-01 17:57:56.576 UTC] [V] 485DevCtl <C3:01> set2 StatusCode[020101]
[2026-08-01 17:57:56.576 UTC] [V] OFSCtrl Bat[0301] StCd[020101]->st[1].
[2026-08-01 17:57:56.567 UTC] [V] OFSCtrl out of control time.
[2026-08-01 17:57:56.578 UTC] [V] OFSCtrl Control pv-pcs proc start.
[2026-08-01 17:57:56.585 UTC] [V] OFSCtrl set batt status:[0301]:Drive, All:[0301]:Drive,[0302]:Drive,[0303]:Drive,[0304]:Drive, [DRIVE] 
[2026-08-01 17:57:56.585 UTC] [V] OFSCtrl change set SOC(t):44.750000 drive cnt:4
[2026-08-01 17:57:56.586 UTC] [V] OFSCtrl NOD_month:-445.000000 = (NOD_month:13 - ((nod_max_/30):23.333333 * (cnt-1):12) * (30/cnt):1.666667 
[2026-08-01 17:57:56.587 UTC] [V] OFSCtrl PCS ratio_month:113.496241 = -k_inhibition_ratio_month:-0.097744 * NOD_month:-445.000000 + inhibition_ratio_max:70
[2026-08-01 17:57:56.587 UTC] [V] OFSCtrl PCS 05 inhibition_ratio:70.000000 = max(ratio_min:5, min(ratio:70, ratio_hour:70.000000, ratio_day:70.000000, ratio_month:113.496241))
[2026-08-01 17:57:56.587 UTC] [D] OFSCtrl pv-pcs ctrl val:0.000000 old:0.000000
[2026-08-01 17:57:56.592 UTC] [V] OCHisDB set rate:0 t_rate:0 cnt:32
[2026-08-01 17:57:56.593 UTC] [V] 485ChCtl <C2> pv-pcs limit on [0.000000] request.
[2026-08-01 17:57:56.595 UTC] [V] OFSCtrl Control pv-pcs proc:BATT_CHK->01->02->03->04->05->06->07->09->09->10->11->12
[2026-08-01 17:57:56.596 UTC] [V] OFSCtrl Nod calc proc start.
[2026-08-01 17:57:56.598 UTC] [V] 485DevCtl <C3:01> set2 StatusCode[020101] DeviceName[蓄電池1] DeviceNumber[1]
[2026-08-01 17:57:56.600 UTC] [V] OFSCtrl ProcNodCountCalculation culc nod skip stop:0, pause:0, ctl_time:0
[2026-08-01 17:57:56.602 UTC] [V] OFSCtrl update p_co_old:21560.000000
[2026-08-01 17:57:56.602 UTC] [V] 485ChCtl <C3> set rt:0
[2026-08-01 17:57:56.603 UTC] [V] OFSCtrl Nod calc proc:
[2026-08-01 17:57:56.612 UTC] [V] 485ChCtl <C1> set rt:0
[2026-08-01 17:57:56.612 UTC] [V] 485DevCtl <C1:04> device_type:CO-Meter
[2026-08-01 17:57:56.655 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:57:56.655 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:57:56.663 UTC] [V] 485ChCtl <C2> pv-pcs send request.
[2026-08-01 17:57:56.664 UTC] [D] VarInf update ofs_rate:0.000000
[2026-08-01 17:57:56.664 UTC] [V] VarInf LimitSet rt[2] val[170] key[ValueOn]
[2026-08-01 17:57:56.664 UTC] [D] VarInf output_mode:8
[2026-08-01 17:57:56.664 UTC] [D] VarInf update ofs_rate:0.000000
[2026-08-01 17:57:56.665 UTC] [D] VarInf Limit setRate[0.000000] rate[0.000000] value100[1000.000000] value0[0.000000]
[2026-08-01 17:57:56.665 UTC] [V] 485DevCtl <C2:01> ChangeOutputRateToDevice rate:0.000000 set_rate1
[2026-08-01 17:57:56.665 UTC] [D] VarInf Limit rt[2] int_set_rate[1] server_rate[0.000000] rated_output[100.000000] solar_battery_power[100.000000]
[2026-08-01 17:57:56.666 UTC] [D] 485AcReq <C2:01> PutOStreamForBc [3][0d000010138e00020400aa0001466f]
[2026-08-01 17:57:56.679 UTC] [V] 485ChCtl <C3> battery send request.1
[2026-08-01 17:57:56.680 UTC] [D] VarInf Limit_Bat rt[2]set val[55] set rate[11.000000] value100[500] value-100[-500]
[2026-08-01 17:57:56.681 UTC] [D] VarInf Limit_Bat rt[2]set val[55] set rate[11.000000] value100[500] value-100[-500]
[2026-08-01 17:57:56.682 UTC] [D] VarInf Limit_Bat rt[2]set val[66] set rate[13.200000] value100[500] value-100[-500]
[2026-08-01 17:57:56.685 UTC] [D] VarInf Limit_Bat rt[2]set val[55] set rate[11.000000] value100[500] value-100[-500]
[2026-08-01 17:57:56.693 UTC] [D] 485AcReq <C3:01> PutOStream [6][0f000001000000090110278e0001020037]
[2026-08-01 17:57:56.693 UTC] [D] 485AcReq <C3:02> PutOStream [6][0f000001000000090110278e0001020037]
[2026-08-01 17:57:56.694 UTC] [D] 485AcReq <C3:03> PutOStream [6][0f000001000000090110278e0001020042]
[2026-08-01 17:57:56.700 UTC] [D] 485AcReq <C3:04> PutOStream [6][0f000001000000090110278e0001020037]
[2026-08-01 17:57:56.755 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:57:56.755 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:57:56.855 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:57:56.855 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:57:56.894 UTC] [V] 485DevCtl <C3:01> AnalyzeResponseData proc restart cnt:17956 UPRstat:0
[2026-08-01 17:57:56.897 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:57:56.897 UTC] [D] 485DevCtl <C3:01> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:57:56.897 UTC] [D] 485DevCtl <C3:01> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:57:56.897 UTC] [V] 485DevCtl <C3:01> device_type:Battery
[2026-08-01 17:57:56.898 UTC] [V] 485DevCtl <C3:02> AnalyzeResponseData proc restart cnt:17956 UPRstat:0
[2026-08-01 17:57:56.899 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:57:56.899 UTC] [D] 485DevCtl <C3:02> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:57:56.900 UTC] [D] 485DevCtl <C3:02> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:57:56.900 UTC] [V] 485DevCtl <C3:02> device_type:Battery
[2026-08-01 17:57:56.900 UTC] [V] 485DevCtl <C3:03> AnalyzeResponseData proc restart cnt:17956 UPRstat:0
[2026-08-01 17:57:56.901 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:57:56.923 UTC] [D] 485DevCtl <C3:03> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:57:56.925 UTC] [D] 485DevCtl <C3:03> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:57:56.926 UTC] [V] 485DevCtl <C3:03> device_type:Battery
[2026-08-01 17:57:56.932 UTC] [V] 485DevCtl <C3:04> AnalyzeResponseData proc restart cnt:17956 UPRstat:0
[2026-08-01 17:57:56.949 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:57:56.951 UTC] [D] 485DevCtl <C3:04> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:57:56.951 UTC] [D] 485DevCtl <C3:04> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:57:56.951 UTC] [V] 485DevCtl <C3:04> device_type:Battery
[2026-08-01 17:57:56.951 UTC] [V] 485ChCtl <C3> set rt:0
[2026-08-01 17:57:56.955 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:57:56.955 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:57:56.956 UTC] [V] 485ChCtl <C2> set rt:0
[2026-08-01 17:57:56.979 UTC] [V] 485ChCtl <C3> StartDeviceCommunicationForOutputFluctuationSuppressionControlBroadcast 4 cnt:179512, monitor_cnt:56, bc_elapsed:179512, min:10, max:40
[2026-08-01 17:57:56.979 UTC] [V] 485DevCtl <C3:02> Dev not PCS IsNeedToChangeOControlState
[2026-08-01 17:57:56.979 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :1
[2026-08-01 17:57:56.980 UTC] [V] 485ChCtl <C3> send request:Sungrow11
[2026-08-01 17:57:56.981 UTC] [D] 485AcReq <C3:02> PutOStream [1][0c00000100000006010327470048]
[2026-08-01 17:57:57.012 UTC] [V] OFSCtrl [/var/local/solajithome/function/output_fluctuation_suppression/batt_data] write success.
[2026-08-01 17:57:57.055 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:57:57.055 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:57:57.133 UTC] [V] 485DevCtl <C3:02> AnalyzeResponseData proc restart cnt:17956 UPRstat:0
[2026-08-01 17:57:57.139 UTC] [D] 485DevCtl <C3:02> RcvDat status[0] len[153] [0001000000930103900000000000000000005500550000005500aa00a000fa000000fa0001000000000000000000000019ffffffffffffffffffffffffffffffffffffffffffff000100000000ffff0000ffffffffffffffffffffffffffffffffffff0fa0177003e800000e101388000a000a00000000195020d000000000000000550055fffb0032ffff0000000000000000000000000037]
[2026-08-01 17:57:57.139 UTC] [D] 485DevCtl <C3:02> ResCnd OperationId [1] IsNormal[1]  ConditionType [lggrdev:Normal] Action[-1]
[2026-08-01 17:57:57.140 UTC] [V] 485DevCtl <C3:02> [01][753049][0.000000][0][]
[2026-08-01 17:57:57.140 UTC] [V] SummDat SetVrmValue dev_id:14 val:0.000000 sc:0
[2026-08-01 17:57:57.140 UTC] [V] OCMgr SetMeterValue PhId:0302, branchNo:01, valueId:753049, value:0.000000, scaleFactor:0, devId:14
[2026-08-01 17:57:57.141 UTC] [V] OFSCtrl Rcv set BATT(t-1)[0302]:0.110000 value:5500.000000/50000 BATT(t-1):0.115500 <- 23100.000000/200000
[2026-08-01 17:57:57.141 UTC] [V] 485DevCtl <C3:02> [01][753102][55.000000][1][kW]
[2026-08-01 17:57:57.141 UTC] [V] SummDat SetVrmValue dev_id:14 val:55.000000 sc:1
[2026-08-01 17:57:57.141 UTC] [V] OCMgr SetMeterValue PhId:0302, branchNo:01, valueId:753102, value:55.000000, scaleFactor:1, devId:14
[2026-08-01 17:57:57.142 UTC] [V] 485DevCtl <C3:02> device_type:Battery
[2026-08-01 17:57:57.155 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:57:57.156 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:57:57.183 UTC] [V] 485ChCtl <C3> set rt:0
[2026-08-01 17:57:57.255 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:57:57.255 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:57:57.279 UTC] [V] 485ChCtl <C3> StartDeviceCommunicationForOutputFluctuationSuppressionControlBroadcast 4 cnt:179515, monitor_cnt:59, bc_elapsed:179515, min:10, max:40
[2026-08-01 17:57:57.279 UTC] [V] 485DevCtl <C3:03> Dev not PCS IsNeedToChangeOControlState
[2026-08-01 17:57:57.279 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :4
[2026-08-01 17:57:57.280 UTC] [V] 485ChCtl <C3> send request:Sungrow11
[2026-08-01 17:57:57.281 UTC] [D] 485AcReq <C3:03> PutOStream [4][0c00000100000006010427f0002f]
[2026-08-01 17:57:57.355 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:57:57.355 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:57:57.423 UTC] [V] 485DevCtl <C3:03> AnalyzeResponseData proc restart cnt:17956 UPRstat:0
[2026-08-01 17:57:57.446 UTC] [D] 485DevCtl <C3:03> RcvDat status[0] len[103] [00010000006101045e1e94005700430ffc0fba1035005d005e005e004100000000000000000000000000000001000000b26e830000647d0000012c0000006700ad246800000001177103e701de000000ad0361000013a70000db28000100410000000000b20000]
[2026-08-01 17:57:57.446 UTC] [D] 485DevCtl <C3:03> ResCnd OperationId [4] IsNormal[1]  ConditionType [lggrdev:Normal] Action[-1]
[2026-08-01 17:57:57.446 UTC] [V] 485DevCtl <C3:03> [05][753053][0.000000][0][]
[2026-08-01 17:57:57.448 UTC] [V] SummDat SetVrmValue dev_id:15 val:0.000000 sc:0
[2026-08-01 17:57:57.453 UTC] [V] OCMgr SetMeterValue PhId:0303, branchNo:05, valueId:753053, value:0.000000, scaleFactor:0, devId:15
[2026-08-01 17:57:57.455 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:57:57.455 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:57:57.456 UTC] [V] 485ChCtl <C1> StartDeviceCommunicationForOutputFluctuationSuppressionControlBroadcast 4 cnt:179517, monitor_cnt:100, bc_elapsed:17, min:10, max:40
[2026-08-01 17:57:57.456 UTC] [V] OFSCtrl /var/local/solajithome/function/output_fluctuation_suppression/state is exist:0
[2026-08-01 17:57:57.458 UTC] [V] 485DevCtl <C3:03> [06][753053][0.000000][0][]
[2026-08-01 17:57:57.460 UTC] [V] SummDat SetVrmValue dev_id:15 val:0.000000 sc:0
[2026-08-01 17:57:57.467 UTC] [V] OCMgr SetMeterValue PhId:0303, branchNo:06, valueId:753053, value:0.000000, scaleFactor:0, devId:15
[2026-08-01 17:57:57.471 UTC] [V] 485DevCtl <C3:03> [07][753053][0.000000][0][]
[2026-08-01 17:57:57.471 UTC] [V] SummDat SetVrmValue dev_id:15 val:0.000000 sc:0
[2026-08-01 17:57:57.471 UTC] [V] OCMgr SetMeterValue PhId:0303, branchNo:07, valueId:753053, value:0.000000, scaleFactor:0, devId:15
[2026-08-01 17:57:57.472 UTC] [V] 485DevCtl <C3:03> device_type:Battery
[2026-08-01 17:57:57.486 UTC] [V] 485DevCtl <C3:03> set2 StatusCode[020101]
[2026-08-01 17:57:57.487 UTC] [V] OFSCtrl Bat[0303] StCd[020101]->st[1].
[2026-08-01 17:57:57.499 UTC] [V] OFSCtrl set batt status:[0303]:Drive, All:[0301]:Drive,[0302]:Drive,[0303]:Drive,[0304]:Drive, [DRIVE] 
[2026-08-01 17:57:57.499 UTC] [V] OFSCtrl change set SOC(t):44.750000 drive cnt:4
[2026-08-01 17:57:57.500 UTC] [V] 485DevCtl <C3:03> set2 StatusCode[020101] DeviceName[蓄電池3] DeviceNumber[1]
[2026-08-01 17:57:57.500 UTC] [V] 485ChCtl <C3> set rt:0
[2026-08-01 17:57:57.555 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:57:57.556 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:57:57.556 UTC] [V] OFSCtrl Control charge discharge proc start.
[2026-08-01 17:57:57.556 UTC] [V] OFSCtrl CHG 20 p_th(t):21343.350000 = p_th_old_:21333.450000 + lev_cd_:0.100000 * (total_pcs_capacity_:297000.000000 * cof_spec_:2.000000 / 60 * (time_threshold_renew:10.000000 * 10)), min:-2062.500000, max:407900.000000
[2026-08-01 17:57:57.557 UTC] [V] OFSCtrl CHG 21 batt_w:22126.249079 = old:22081.385579 +  kp:0.550000 * e:80.850000 + ki:0.000000 * sume:-11612.699857 + kd:0.040000 * (e:80.850000 - e1:70.950000)
[2026-08-01 17:57:57.557 UTC] [V] 485ChCtl <C1> StartDeviceCommunicationForOutputFluctuationSuppressionControlBroadcast 4 cnt:179518, monitor_cnt:101, bc_elapsed:18, min:10, max:40
[2026-08-01 17:57:57.557 UTC] [V] 485DevCtl <C1:02> Dev not PCS IsNeedToChangeOControlState
[2026-08-01 17:57:57.557 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :1
[2026-08-01 17:57:57.558 UTC] [V] 485ChCtl <C1> send request:IMT01
[2026-08-01 17:57:57.559 UTC] [D] 485AcReq <C1:02> PutOStream [1][08000204000200019039]
[2026-08-01 17:57:57.562 UTC] [V] OFSCtrl CHG 21 battery threshold min:20000.000000 <= bat:22126.249079 <= max:196000.000000, adjust charge:0.000000, discharge:1000.000000
[2026-08-01 17:57:57.563 UTC] [V] OFSCtrl CHG 29 q:55.000000, mod(round):1.000000
[2026-08-01 17:57:57.564 UTC] [V] OFSCtrl discharge bat_w[0303]:6600.000000 += adjust:1000.000000
[2026-08-01 17:57:57.565 UTC] [D] OFSCtrl battery ctrl val:11.100000
[2026-08-01 17:57:57.570 UTC] [V] 485ChCtl <C3> battery limit on [55.000000,55.000000,66.000000,55.000000,] request.
[2026-08-01 17:57:57.573 UTC] [V] OFSCtrl Control charge discharge proc:01->02->BATT_CHK->03->04->05->06->10->12->13->15->16->17->20->21->22->23->24->25->27->23->24->25->27->23->24->25->27->23->24->25->27->28->29->30->31->32->30->31->32->30->31->32->30->31->32->33->34
[2026-08-01 17:57:57.579 UTC] [V] 485ChCtl <C3> battery send request.1
[2026-08-01 17:57:57.579 UTC] [D] VarInf Limit_Bat rt[2]set val[55] set rate[11.000000] value100[500] value-100[-500]
[2026-08-01 17:57:57.580 UTC] [D] VarInf Limit_Bat rt[2]set val[55] set rate[11.000000] value100[500] value-100[-500]
[2026-08-01 17:57:57.581 UTC] [D] VarInf Limit_Bat rt[2]set val[66] set rate[13.200000] value100[500] value-100[-500]
[2026-08-01 17:57:57.587 UTC] [D] VarInf Limit_Bat rt[2]set val[55] set rate[11.000000] value100[500] value-100[-500]
[2026-08-01 17:57:57.595 UTC] [D] 485AcReq <C3:01> PutOStream [6][0f000001000000090110278e0001020037]
[2026-08-01 17:57:57.596 UTC] [D] 485AcReq <C3:02> PutOStream [6][0f000001000000090110278e0001020037]
[2026-08-01 17:57:57.597 UTC] [D] 485AcReq <C3:03> PutOStream [6][0f000001000000090110278e0001020042]
[2026-08-01 17:57:57.597 UTC] [D] 485AcReq <C3:04> PutOStream [6][0f000001000000090110278e0001020037]
[2026-08-01 17:57:57.655 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:57:57.655 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:57:57.755 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:57:57.755 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:57:57.765 UTC] [V] 485DevCtl <C3:01> AnalyzeResponseData proc restart cnt:17957 UPRstat:0
[2026-08-01 17:57:57.766 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:57:57.767 UTC] [D] 485DevCtl <C3:01> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:57:57.767 UTC] [D] 485DevCtl <C3:01> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:57:57.767 UTC] [V] 485DevCtl <C3:01> device_type:Battery
[2026-08-01 17:57:57.767 UTC] [V] 485DevCtl <C3:02> AnalyzeResponseData proc restart cnt:17957 UPRstat:0
[2026-08-01 17:57:57.768 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:57:57.769 UTC] [D] 485DevCtl <C3:02> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:57:57.769 UTC] [D] 485DevCtl <C3:02> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:57:57.769 UTC] [V] 485DevCtl <C3:02> device_type:Battery
[2026-08-01 17:57:57.769 UTC] [V] 485DevCtl <C3:03> AnalyzeResponseData proc restart cnt:17957 UPRstat:0
[2026-08-01 17:57:57.770 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:57:57.771 UTC] [D] 485DevCtl <C3:03> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:57:57.771 UTC] [D] 485DevCtl <C3:03> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:57:57.771 UTC] [V] 485DevCtl <C3:03> device_type:Battery
[2026-08-01 17:57:57.771 UTC] [V] 485DevCtl <C3:04> AnalyzeResponseData proc restart cnt:17957 UPRstat:0
[2026-08-01 17:57:57.835 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:57:57.845 UTC] [D] 485DevCtl <C3:04> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:57:57.846 UTC] [D] 485DevCtl <C3:04> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:57:57.847 UTC] [V] 485DevCtl <C3:04> device_type:Battery
[2026-08-01 17:57:57.852 UTC] [V] 485ChCtl <C3> set rt:0
[2026-08-01 17:57:57.855 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:57:57.855 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:57:57.879 UTC] [V] 485ChCtl <C3> StartDeviceCommunicationForOutputFluctuationSuppressionControlBroadcast 4 cnt:179521, monitor_cnt:65, bc_elapsed:179521, min:10, max:40
[2026-08-01 17:57:57.879 UTC] [V] 485DevCtl <C3:04> Dev not PCS IsNeedToChangeOControlState
[2026-08-01 17:57:57.879 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :5
[2026-08-01 17:57:57.880 UTC] [V] 485ChCtl <C3> send request:Sungrow11
[2026-08-01 17:57:57.881 UTC] [D] 485AcReq <C3:04> PutOStream [5][0c00000100000006010469780001]
[2026-08-01 17:57:57.906 UTC] [V] 485DevCtl <C1:02> AnalyzeResponseData proc restart cnt:17975 UPRstat:0
[2026-08-01 17:57:57.907 UTC] [V] Res no response condition. set normal condition.
[2026-08-01 17:57:57.907 UTC] [D] 485DevCtl <C1:02> RcvDat status[2] len[7] [020402020fbc54]
[2026-08-01 17:57:57.907 UTC] [D] 485DevCtl <C1:02> ResCnd OperationId [1] IsNormal[1] 
[2026-08-01 17:57:57.908 UTC] [V] 485DevCtl <C1:02> [01][431005][277.000000][1][°C]
[2026-08-01 17:57:57.908 UTC] [V] SummDat SetVrmValue dev_id:2 val:27700.000000 sc:3
[2026-08-01 17:57:57.908 UTC] [V] OCMgr SetMeterValue PhId:0102, branchNo:01, valueId:431005, value:277.000000, scaleFactor:1, devId:2
[2026-08-01 17:57:57.908 UTC] [V] 485DevCtl <C1:02> device_type:
[2026-08-01 17:57:57.909 UTC] [V] 485ChCtl <C1> set rt:0
[2026-08-01 17:57:57.955 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:57:57.955 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:57:57.957 UTC] [V] 485ChCtl <C1> StartDeviceCommunicationForOutputFluctuationSuppressionControlBroadcast 4 cnt:179522, monitor_cnt:105, bc_elapsed:22, min:10, max:40
[2026-08-01 17:57:57.957 UTC] [V] 485DevCtl <C1:03> Dev not PCS IsNeedToChangeOControlState
[2026-08-01 17:57:57.957 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :1
[2026-08-01 17:57:57.958 UTC] [V] 485ChCtl <C1> send request:omron03
[2026-08-01 17:57:57.959 UTC] [D] 485AcReq <C1:03> PutOStream [1][08000303000000144427]
[2026-08-01 17:57:58.012 UTC] [V] OFSCtrl [/var/local/solajithome/function/output_fluctuation_suppression/batt_data] write success.
[2026-08-01 17:57:58.014 UTC] [V] 485DevCtl <C3:04> AnalyzeResponseData proc restart cnt:17957 UPRstat:0
[2026-08-01 17:57:58.015 UTC] [D] 485DevCtl <C3:04> RcvDat status[0] len[11] [0001000000050104020128]
[2026-08-01 17:57:58.015 UTC] [D] 485DevCtl <C3:04> ResCnd OperationId [5] IsNormal[1]  ConditionType [lggrdev:Normal] Action[-1]
[2026-08-01 17:57:58.017 UTC] [V] 485DevCtl <C3:04> [01][121005][296.000000][1][℃]
[2026-08-01 17:57:58.017 UTC] [V] SummDat SetVrmValue dev_id:16 val:29600.000000 sc:3
[2026-08-01 17:57:58.018 UTC] [V] OCMgr SetMeterValue PhId:0304, branchNo:01, valueId:121005, value:296.000000, scaleFactor:1, devId:16
[2026-08-01 17:57:58.018 UTC] [V] 485DevCtl <C3:04> device_type:Battery
[2026-08-01 17:57:58.031 UTC] [V] 485ChCtl <C3> set rt:0
[2026-08-01 17:57:58.032 UTC] [D] 485ChCtl <C3> monitoring dev All Send
[2026-08-01 17:57:58.055 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:57:58.055 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:57:58.155 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:57:58.155 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:57:58.255 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:57:58.255 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:57:58.355 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:57:58.355 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:57:58.364 UTC] [V] 485DevCtl <C1:03> AnalyzeResponseData proc restart cnt:17975 UPRstat:0
[2026-08-01 17:57:58.365 UTC] [V] Res no response condition. set normal condition.
[2026-08-01 17:57:58.366 UTC] [D] 485DevCtl <C1:03> RcvDat status[2] len[45] [0303280000fc410001039f000100710000060d00000cb900000fb400000003000002580000274400000064139a]
[2026-08-01 17:57:58.366 UTC] [D] 485DevCtl <C1:03> ResCnd OperationId [1] IsNormal[1] 
[2026-08-01 17:57:58.367 UTC] [V] 485DevCtl <C1:03> [01][301200][64577.000000][1][V]
[2026-08-01 17:57:58.367 UTC] [V] SummDat SetVrmValue dev_id:3 val:6457700.000000 sc:3
[2026-08-01 17:57:58.367 UTC] [V] OCMgr SetMeterValue PhId:0103, branchNo:01, valueId:301200, value:64577.000000, scaleFactor:1, devId:3
[2026-08-01 17:57:58.367 UTC] [V] 485DevCtl <C1:03> [01][301201][1549.000000][3][A]
[2026-08-01 17:57:58.367 UTC] [V] SummDat SetVrmValue dev_id:3 val:1549.000000 sc:3
[2026-08-01 17:57:58.368 UTC] [V] OCMgr SetMeterValue PhId:0103, branchNo:01, valueId:301201, value:1549.000000, scaleFactor:3, devId:3
[2026-08-01 17:57:58.368 UTC] [V] OFSCtrl Rcv set p_grid:1000.000000
[2026-08-01 17:57:58.368 UTC] [V] 485DevCtl <C1:03> [01][601202][100.000000][2][kW]
[2026-08-01 17:57:58.368 UTC] [V] SummDat SetVrmValue dev_id:3 val:1000.000000 sc:3
[2026-08-01 17:57:58.368 UTC] [V] OCMgr SetMeterValue PhId:0103, branchNo:01, valueId:601202, value:100.000000, scaleFactor:2, devId:3
[2026-08-01 17:57:58.369 UTC] [V] 485DevCtl <C1:03> device_type:Grid-Meter
[2026-08-01 17:57:58.369 UTC] [V] 485ChCtl <C1> set rt:0
[2026-08-01 17:57:58.455 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:57:58.455 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:57:58.456 UTC] [V] 485ChCtl <C1> StartDeviceCommunicationForOutputFluctuationSuppressionControlBroadcast 4 cnt:179527, monitor_cnt:110, bc_elapsed:27, min:10, max:40
[2026-08-01 17:57:58.555 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:57:58.555 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:57:58.555 UTC] [V] OFSCtrl Control charge discharge proc start.
[2026-08-01 17:57:58.555 UTC] [V] OFSCtrl CHG 20 p_th(t):21313.650000 = p_th_old_:21343.350000 + lev_cd_:-0.300000 * (total_pcs_capacity_:297000.000000 * cof_spec_:2.000000 / 60 * (time_threshold_renew:10.000000 * 10)), min:-2062.500000, max:407900.000000
[2026-08-01 17:57:58.556 UTC] [V] OFSCtrl CHG 21 batt_w:22153.193579 = old:22126.249079 +  kp:0.550000 * e:51.150000 + ki:0.000000 * sume:-11561.549857 + kd:0.040000 * (e:51.150000 - e1:80.850000)
[2026-08-01 17:57:58.556 UTC] [V] OFSCtrl CHG 21 battery threshold min:20000.000000 <= bat:22153.193579 <= max:196000.000000, adjust charge:0.000000, discharge:1000.000000
[2026-08-01 17:57:58.556 UTC] [V] OFSCtrl CHG 29 q:55.000000, mod(round):2.000000
[2026-08-01 17:57:58.556 UTC] [V] OFSCtrl discharge bat_w[0303]:6600.000000 += adjust:1000.000000
[2026-08-01 17:57:58.556 UTC] [D] OFSCtrl battery ctrl val:11.100000
[2026-08-01 17:57:58.557 UTC] [V] 485ChCtl <C1> StartDeviceCommunicationForOutputFluctuationSuppressionControlBroadcast 4 cnt:179528, monitor_cnt:111, bc_elapsed:28, min:10, max:40
[2026-08-01 17:57:58.557 UTC] [V] 485DevCtl <C1:05> Dev not PCS IsNeedToChangeOControlState
[2026-08-01 17:57:58.557 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :1
[2026-08-01 17:57:58.558 UTC] [V] 485ChCtl <C1> send request:omron04
[2026-08-01 17:57:58.558 UTC] [D] 485AcReq <C1:05> PutOStream [1][0800050300030014b441]
[2026-08-01 17:57:58.560 UTC] [V] 485ChCtl <C3> battery limit on [55.000000,56.000000,66.000000,55.000000,] request.
[2026-08-01 17:57:58.561 UTC] [V] OFSCtrl Control charge discharge proc:01->02->BATT_CHK->03->04->05->06->10->12->13->15->16->18->19->20->21->22->23->24->25->27->23->24->25->27->23->24->25->27->23->24->25->27->28->29->30->31->32->30->31->32->30->31->32->30->31->32->33->34
[2026-08-01 17:57:58.578 UTC] [V] 485ChCtl <C3> battery send request.1
[2026-08-01 17:57:58.579 UTC] [D] VarInf Limit_Bat rt[2]set val[55] set rate[11.000000] value100[500] value-100[-500]
[2026-08-01 17:57:58.580 UTC] [D] VarInf Limit_Bat rt[2]set val[56] set rate[11.200000] value100[500] value-100[-500]
[2026-08-01 17:57:58.581 UTC] [D] VarInf Limit_Bat rt[2]set val[66] set rate[13.200000] value100[500] value-100[-500]
[2026-08-01 17:57:58.582 UTC] [D] VarInf Limit_Bat rt[2]set val[55] set rate[11.000000] value100[500] value-100[-500]
[2026-08-01 17:57:58.591 UTC] [D] 485AcReq <C3:01> PutOStream [6][0f000001000000090110278e0001020037]
[2026-08-01 17:57:58.591 UTC] [D] 485AcReq <C3:02> PutOStream [6][0f000001000000090110278e0001020038]
[2026-08-01 17:57:58.592 UTC] [D] 485AcReq <C3:03> PutOStream [6][0f000001000000090110278e0001020042]
[2026-08-01 17:57:58.593 UTC] [D] 485AcReq <C3:04> PutOStream [6][0f000001000000090110278e0001020037]
[2026-08-01 17:57:58.655 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:57:58.655 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:57:58.755 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:57:58.755 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:57:58.764 UTC] [V] 485DevCtl <C3:01> AnalyzeResponseData proc restart cnt:17958 UPRstat:0
[2026-08-01 17:57:58.767 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:57:58.768 UTC] [D] 485DevCtl <C3:01> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:57:58.768 UTC] [D] 485DevCtl <C3:01> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:57:58.768 UTC] [V] 485DevCtl <C3:01> device_type:Battery
[2026-08-01 17:57:58.768 UTC] [V] 485DevCtl <C3:02> AnalyzeResponseData proc restart cnt:17958 UPRstat:0
[2026-08-01 17:57:58.770 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:57:58.770 UTC] [D] 485DevCtl <C3:02> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:57:58.770 UTC] [D] 485DevCtl <C3:02> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:57:58.770 UTC] [V] 485DevCtl <C3:02> device_type:Battery
[2026-08-01 17:57:58.771 UTC] [V] 485DevCtl <C3:03> AnalyzeResponseData proc restart cnt:17958 UPRstat:0
[2026-08-01 17:57:58.812 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:57:58.813 UTC] [D] 485DevCtl <C3:03> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:57:58.813 UTC] [D] 485DevCtl <C3:03> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:57:58.813 UTC] [V] 485DevCtl <C3:03> device_type:Battery
[2026-08-01 17:57:58.813 UTC] [V] 485DevCtl <C3:04> AnalyzeResponseData proc restart cnt:17958 UPRstat:0
[2026-08-01 17:57:58.834 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:57:58.846 UTC] [D] 485DevCtl <C3:04> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:57:58.847 UTC] [D] 485DevCtl <C3:04> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:57:58.847 UTC] [V] 485DevCtl <C3:04> device_type:Battery
[2026-08-01 17:57:58.847 UTC] [V] 485ChCtl <C3> set rt:0
[2026-08-01 17:57:58.855 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:57:58.855 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:57:58.950 UTC] [V] 485DevCtl <C1:05> AnalyzeResponseData proc restart cnt:17976 UPRstat:0
[2026-08-01 17:57:58.951 UTC] [V] Res no response condition. set normal condition.
[2026-08-01 17:57:58.952 UTC] [D] 485DevCtl <C1:05> RcvDat status[2] len[45] [050328000021cc000013b1000017b8ffffffd800000258ffffe01cffffffafffffb701ffffff4600264cafe1ea]
[2026-08-01 17:57:58.953 UTC] [D] 485DevCtl <C1:05> ResCnd OperationId [1] IsNormal[1] 
[2026-08-01 17:57:58.953 UTC] [V] OFSCtrl Rcv set p_pv:-810.000000
[2026-08-01 17:57:58.953 UTC] [V] 485DevCtl <C1:05> [01][601259][-81.000000][2][kW]
[2026-08-01 17:57:58.953 UTC] [V] SummDat SetVrmValue dev_id:5 val:-810.000000 sc:3
[2026-08-01 17:57:58.954 UTC] [V] OCMgr SetMeterValue PhId:0105, branchNo:01, valueId:601259, value:-81.000000, scaleFactor:2, devId:5
[2026-08-01 17:57:58.955 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:57:58.955 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:57:58.960 UTC] [V] 485DevCtl <C1:05> [01][603259][2509999.000000][1][kWh]
[2026-08-01 17:57:58.965 UTC] [V] SummDat SetVrmValue dev_id:5 val:2509999.000000 sc:1
[2026-08-01 17:57:58.966 UTC] [V] OCMgr SetMeterValue PhId:0105, branchNo:01, valueId:603259, value:2509999.000000, scaleFactor:1, devId:5
[2026-08-01 17:57:58.970 UTC] [V] 485DevCtl <C1:05> device_type:PV-Meter
[2026-08-01 17:57:58.982 UTC] [V] 485ChCtl <C1> set rt:0
[2026-08-01 17:57:59.012 UTC] [V] OFSCtrl [/var/local/solajithome/function/output_fluctuation_suppression/batt_data] write success.
[2026-08-01 17:57:59.055 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:57:59.055 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:57:59.057 UTC] [V] 485ChCtl <C1> StartDeviceCommunicationForOutputFluctuationSuppressionControlBroadcast 4 cnt:179533, monitor_cnt:116, bc_elapsed:33, min:10, max:40
[2026-08-01 17:57:59.057 UTC] [V] 485DevCtl <C1:06> Dev not PCS IsNeedToChangeOControlState
[2026-08-01 17:57:59.057 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :1
[2026-08-01 17:57:59.058 UTC] [V] 485ChCtl <C1> send request:omron06
[2026-08-01 17:57:59.059 UTC] [D] 485AcReq <C1:06> PutOStream [1][08000603000000144472]
[2026-08-01 17:57:59.155 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:57:59.155 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:57:59.255 UTC] [V] OFSCtrl limit chk 400 < 800 < [1195->1195] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:57:59.255 UTC] [V] OFSCtrl angif value:1195 power_val_:21468.750000
[2026-08-01 17:57:59.355 UTC] [V] OFSCtrl limit chk 400 < 800 < [1195->1195] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:57:59.355 UTC] [V] OFSCtrl angif value:1195 power_val_:21468.750000
[2026-08-01 17:57:59.447 UTC] [V] 485DevCtl <C1:06> AnalyzeResponseData proc restart cnt:17976 UPRstat:0
[2026-08-01 17:57:59.447 UTC] [V] Res no response condition. set normal condition.
[2026-08-01 17:57:59.448 UTC] [D] 485DevCtl <C1:06> RcvDat status[2] len[45] [0603280000080400000824000008430000fc380000fbc00000f91e0000006400000258000370dc000008cfdd97]
[2026-08-01 17:57:59.448 UTC] [D] 485DevCtl <C1:06> ResCnd OperationId [1] IsNormal[1] 
[2026-08-01 17:57:59.449 UTC] [V] OFSCtrl Rcv set p_batt:22550.000000
[2026-08-01 17:57:59.449 UTC] [V] 485DevCtl <C1:06> [01][601237][2255.000000][2][kW]
[2026-08-01 17:57:59.449 UTC] [V] SummDat SetVrmValue dev_id:6 val:22550.000000 sc:3
[2026-08-01 17:57:59.449 UTC] [V] OCMgr SetMeterValue PhId:0106, branchNo:01, valueId:601237, value:2255.000000, scaleFactor:2, devId:6
[2026-08-01 17:57:59.450 UTC] [V] 485DevCtl <C1:06> device_type:Batt-Meter
[2026-08-01 17:57:59.450 UTC] [V] 485ChCtl <C1> set rt:0
[2026-08-01 17:57:59.454 UTC] [V] OFSCtrl limit chk 400 < 800 < [1195->1195] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:57:59.455 UTC] [V] OFSCtrl angif value:1195 power_val_:21468.750000
[2026-08-01 17:57:59.458 UTC] [D] 485ChCtl <C1> monitoring dev All Send
[2026-08-01 17:57:59.555 UTC] [V] OFSCtrl limit chk 400 < 800 < [1195->1195] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:57:59.555 UTC] [V] OFSCtrl angif value:1195 power_val_:21468.750000
[2026-08-01 17:57:59.555 UTC] [V] OFSCtrl Control charge discharge proc start.
[2026-08-01 17:57:59.556 UTC] [V] OFSCtrl CHG 20 p_th(t):21283.950000 = p_th_old_:21313.650000 + lev_cd_:-0.300000 * (total_pcs_capacity_:297000.000000 * cof_spec_:2.000000 / 60 * (time_threshold_renew:10.000000 * 10)), min:-2062.500000, max:407900.000000
[2026-08-01 17:57:59.556 UTC] [V] OFSCtrl CHG 21 batt_w:22042.115579 = old:22153.193579 +  kp:0.550000 * e:-184.800000 + ki:0.000000 * sume:-11746.349857 + kd:0.040000 * (e:-184.800000 - e1:51.150000)
[2026-08-01 17:57:59.557 UTC] [V] OFSCtrl CHG 21 battery threshold min:20000.000000 <= bat:22042.115579 <= max:196000.000000, adjust charge:0.000000, discharge:1000.000000
[2026-08-01 17:57:59.557 UTC] [V] OFSCtrl CHG 29 q:55.000000, mod(round):0.000000
[2026-08-01 17:57:59.557 UTC] [V] OFSCtrl discharge bat_w[0303]:6500.000000 += adjust:1000.000000
[2026-08-01 17:57:59.557 UTC] [D] OFSCtrl battery ctrl val:11.000000
[2026-08-01 17:57:59.558 UTC] [V] 485ChCtl <C3> battery limit on [55.000000,55.000000,65.000000,55.000000,] request.
[2026-08-01 17:57:59.558 UTC] [V] OFSCtrl Control charge discharge proc:01->02->BATT_CHK->03->04->05->06->10->12->13->15->16->18->19->20->21->22->23->24->25->27->23->24->25->27->23->24->25->27->23->24->25->27->28->29->30->31->32->30->31->32->30->31->32->30->31->32->33->34
[2026-08-01 17:57:59.579 UTC] [V] 485ChCtl <C3> battery send request.1
[2026-08-01 17:57:59.579 UTC] [D] VarInf Limit_Bat rt[2]set val[55] set rate[11.000000] value100[500] value-100[-500]
[2026-08-01 17:57:59.580 UTC] [D] VarInf Limit_Bat rt[2]set val[55] set rate[11.000000] value100[500] value-100[-500]
[2026-08-01 17:57:59.583 UTC] [D] VarInf Limit_Bat rt[2]set val[65] set rate[13.000000] value100[500] value-100[-500]
[2026-08-01 17:57:59.599 UTC] [D] VarInf Limit_Bat rt[2]set val[55] set rate[11.000000] value100[500] value-100[-500]
[2026-08-01 17:57:59.604 UTC] [D] 485AcReq <C3:01> PutOStream [6][0f000001000000090110278e0001020037]
[2026-08-01 17:57:59.605 UTC] [D] 485AcReq <C3:02> PutOStream [6][0f000001000000090110278e0001020037]
[2026-08-01 17:57:59.606 UTC] [D] 485AcReq <C3:03> PutOStream [6][0f000001000000090110278e0001020041]
[2026-08-01 17:57:59.607 UTC] [D] 485AcReq <C3:04> PutOStream [6][0f000001000000090110278e0001020037]
[2026-08-01 17:57:59.655 UTC] [V] OFSCtrl limit chk 400 < 800 < [1195->1195] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:57:59.656 UTC] [V] OFSCtrl angif value:1195 power_val_:21468.750000
[2026-08-01 17:57:59.755 UTC] [V] OFSCtrl limit chk 400 < 800 < [1195->1195] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:57:59.755 UTC] [V] OFSCtrl angif value:1195 power_val_:21468.750000
[2026-08-01 17:57:59.784 UTC] [V] 485DevCtl <C3:01> AnalyzeResponseData proc restart cnt:17959 UPRstat:0
[2026-08-01 17:57:59.789 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:57:59.791 UTC] [D] 485DevCtl <C3:01> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:57:59.792 UTC] [D] 485DevCtl <C3:01> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:57:59.793 UTC] [V] 485DevCtl <C3:01> device_type:Battery
[2026-08-01 17:57:59.801 UTC] [V] 485DevCtl <C3:02> AnalyzeResponseData proc restart cnt:17959 UPRstat:0
[2026-08-01 17:57:59.820 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:57:59.823 UTC] [D] 485DevCtl <C3:02> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:57:59.823 UTC] [D] 485DevCtl <C3:02> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:57:59.824 UTC] [V] 485DevCtl <C3:02> device_type:Battery
[2026-08-01 17:57:59.827 UTC] [V] 485DevCtl <C3:03> AnalyzeResponseData proc restart cnt:17959 UPRstat:0
[2026-08-01 17:57:59.838 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:57:59.845 UTC] [D] 485DevCtl <C3:03> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:57:59.845 UTC] [D] 485DevCtl <C3:03> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:57:59.847 UTC] [V] 485DevCtl <C3:03> device_type:Battery
[2026-08-01 17:57:59.853 UTC] [V] 485DevCtl <C3:04> AnalyzeResponseData proc restart cnt:17959 UPRstat:0
[2026-08-01 17:57:59.855 UTC] [V] OFSCtrl limit chk 400 < 800 < [1195->1195] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:57:59.855 UTC] [V] OFSCtrl angif value:1195 power_val_:21468.750000
[2026-08-01 17:57:59.864 UTC] [V] 485ChCtl <C2> StartDeviceCommunicationForOutputFluctuationSuppressionControlBroadcast 4 cnt:179541, monitor_cnt:50, bc_elapsed:179541, min:10, max:40
[2026-08-01 17:57:59.864 UTC] [V] OFSCtrl /var/local/solajithome/function/output_fluctuation_suppression/state is exist:0
[2026-08-01 17:57:59.864 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :2
[2026-08-01 17:57:59.865 UTC] [V] 485ChCtl <C2> send request:Sungrow08
[2026-08-01 17:57:59.866 UTC] [D] 485AcReq <C2:01> PutOStream [2][0800010413d80002f574]
[2026-08-01 17:57:59.877 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:57:59.884 UTC] [D] 485DevCtl <C3:04> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:57:59.884 UTC] [D] 485DevCtl <C3:04> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:57:59.884 UTC] [V] 485DevCtl <C3:04> device_type:Battery
[2026-08-01 17:57:59.891 UTC] [V] 485ChCtl <C3> set rt:0
[2026-08-01 17:57:59.955 UTC] [V] OFSCtrl limit chk 400 < 800 < [1195->1195] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:57:59.955 UTC] [V] OFSCtrl angif value:1195 power_val_:21468.750000
[2026-08-01 17:58:00.012 UTC] [V] OFSCtrl [/var/local/solajithome/function/output_fluctuation_suppression/batt_data] write success.
[2026-08-01 17:58:00.055 UTC] [V] OFSCtrl limit chk 400 < 800 < [1195->1195] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:00.055 UTC] [V] OFSCtrl angif value:1195 power_val_:21468.750000
[2026-08-01 17:58:00.155 UTC] [V] OFSCtrl limit chk 400 < 800 < [1195->1195] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:00.156 UTC] [V] OFSCtrl angif value:1195 power_val_:21468.750000
[2026-08-01 17:58:00.189 UTC] [D] 485DevCtl <C2:01> RcvDat status[2] len[9] [01040400100000fa41]
[2026-08-01 17:58:00.189 UTC] [D] 485DevCtl <C2:01> ResCnd OperationId [2] IsNormal[0]  ConditionType [lggrdev:Error] Action[4]
[2026-08-01 17:58:00.190 UTC] [V] 485DevCtl <C2:01> device_type:PV-PCS
[2026-08-01 17:58:00.190 UTC] [V] 485DevCtl <C2:01> ExecuteAction name:RestartCounter value0
[2026-08-01 17:58:00.190 UTC] [V] 485DevCtl <C2:01> ExecuteAction set start cnt:0
[2026-08-01 17:58:00.192 UTC] [V] 485ChCtl <C2> set rt:0
[2026-08-01 17:58:00.255 UTC] [V] OFSCtrl limit chk 400 < 800 < [1195->1195] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:00.255 UTC] [V] OFSCtrl angif value:1195 power_val_:21468.750000
[2026-08-01 17:58:00.264 UTC] [V] 485ChCtl <C2> StartDeviceCommunicationForOutputFluctuationSuppressionControlBroadcast 4 cnt:179545, monitor_cnt:54, bc_elapsed:179545, min:10, max:40
[2026-08-01 17:58:00.264 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :2
[2026-08-01 17:58:00.265 UTC] [V] 485ChCtl <C2> send request:Sungrow08
[2026-08-01 17:58:00.266 UTC] [D] 485AcReq <C2:02> PutOStream [2][0800020413d80002f547]
[2026-08-01 17:58:00.355 UTC] [V] OFSCtrl limit chk 400 < 800 < [1195->1195] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:00.355 UTC] [V] OFSCtrl angif value:1195 power_val_:21468.750000
[2026-08-01 17:58:00.455 UTC] [V] OFSCtrl limit chk 400 < 800 < [1195->1195] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:00.455 UTC] [V] OFSCtrl angif value:1195 power_val_:21468.750000
[2026-08-01 17:58:00.555 UTC] [V] OFSCtrl limit chk 400 < 800 < [1195->1195] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:00.555 UTC] [V] OFSCtrl angif value:1195 power_val_:21468.750000
[2026-08-01 17:58:00.555 UTC] [V] OFSCtrl Control charge discharge proc start.
[2026-08-01 17:58:00.556 UTC] [V] OFSCtrl CHG 20 p_th(t):21254.250000 = p_th_old_:21283.950000 + lev_cd_:-0.300000 * (total_pcs_capacity_:297000.000000 * cof_spec_:2.000000 / 60 * (time_threshold_renew:10.000000 * 10)), min:-2062.500000, max:407900.000000
[2026-08-01 17:58:00.556 UTC] [V] OFSCtrl CHG 21 batt_w:21922.952579 = old:22042.115579 +  kp:0.550000 * e:-214.500000 + ki:0.000000 * sume:-11960.849857 + kd:0.040000 * (e:-214.500000 - e1:-184.800000)
[2026-08-01 17:58:00.556 UTC] [V] OFSCtrl CHG 21 battery threshold min:20000.000000 <= bat:21922.952579 <= max:196000.000000, adjust charge:0.000000, discharge:1000.000000
[2026-08-01 17:58:00.557 UTC] [V] OFSCtrl CHG 29 q:54.000000, mod(round):3.000000
[2026-08-01 17:58:00.558 UTC] [V] OFSCtrl discharge bat_w[0303]:6500.000000 += adjust:1000.000000
[2026-08-01 17:58:00.558 UTC] [D] OFSCtrl battery ctrl val:11.000000
[2026-08-01 17:58:00.558 UTC] [V] 485ChCtl <C3> battery limit on [55.000000,55.000000,65.000000,54.000000,] request.
[2026-08-01 17:58:00.559 UTC] [V] OFSCtrl Control charge discharge proc:01->02->BATT_CHK->03->04->05->06->10->12->13->15->16->18->19->20->21->22->23->24->25->27->23->24->25->27->23->24->25->27->23->24->25->27->28->29->30->31->32->30->31->32->30->31->32->30->31->32->33->34
[2026-08-01 17:58:00.579 UTC] [V] 485ChCtl <C3> battery send request.1
[2026-08-01 17:58:00.580 UTC] [D] VarInf Limit_Bat rt[2]set val[55] set rate[11.000000] value100[500] value-100[-500]
[2026-08-01 17:58:00.581 UTC] [D] VarInf Limit_Bat rt[2]set val[55] set rate[11.000000] value100[500] value-100[-500]
[2026-08-01 17:58:00.582 UTC] [D] VarInf Limit_Bat rt[2]set val[65] set rate[13.000000] value100[500] value-100[-500]
[2026-08-01 17:58:00.589 UTC] [D] 485DevCtl <C2:02> RcvDat status[2] len[9] [02040400100000c941]
[2026-08-01 17:58:00.589 UTC] [D] 485DevCtl <C2:02> ResCnd OperationId [2] IsNormal[0]  ConditionType [lggrdev:Error] Action[4]
[2026-08-01 17:58:00.590 UTC] [V] 485DevCtl <C2:02> device_type:PV-PCS
[2026-08-01 17:58:00.590 UTC] [V] 485DevCtl <C2:02> ExecuteAction name:RestartCounter value0
[2026-08-01 17:58:00.590 UTC] [V] 485DevCtl <C2:02> ExecuteAction set start cnt:0
[2026-08-01 17:58:00.590 UTC] [V] 485ChCtl <C2> set rt:0
[2026-08-01 17:58:00.602 UTC] [D] VarInf Limit_Bat rt[2]set val[54] set rate[10.800000] value100[500] value-100[-500]
[2026-08-01 17:58:00.615 UTC] [D] 485AcReq <C3:01> PutOStream [6][0f000001000000090110278e0001020037]
[2026-08-01 17:58:00.616 UTC] [D] 485AcReq <C3:02> PutOStream [6][0f000001000000090110278e0001020037]
[2026-08-01 17:58:00.616 UTC] [D] 485AcReq <C3:03> PutOStream [6][0f000001000000090110278e0001020041]
[2026-08-01 17:58:00.618 UTC] [D] 485AcReq <C3:04> PutOStream [6][0f000001000000090110278e0001020036]
[2026-08-01 17:58:00.655 UTC] [V] OFSCtrl limit chk 400 < 800 < [1195->1195] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:00.655 UTC] [V] OFSCtrl angif value:1195 power_val_:21468.750000
[2026-08-01 17:58:00.664 UTC] [V] 485ChCtl <C2> StartDeviceCommunicationForOutputFluctuationSuppressionControlBroadcast 4 cnt:179549, monitor_cnt:58, bc_elapsed:179549, min:10, max:40
[2026-08-01 17:58:00.665 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :2
[2026-08-01 17:58:00.665 UTC] [V] 485ChCtl <C2> send request:Sungrow08
[2026-08-01 17:58:00.666 UTC] [D] 485AcReq <C2:03> PutOStream [2][0800030413d80002f496]
[2026-08-01 17:58:00.755 UTC] [V] OFSCtrl limit chk 400 < 800 < [1195->1195] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:00.755 UTC] [V] OFSCtrl angif value:1195 power_val_:21468.750000
[2026-08-01 17:58:00.756 UTC] [V] 485DevCtl <C1:01> device_type:Irr-Meter
[2026-08-01 17:58:00.756 UTC] [V] 485DevCtl <C1:01> device_type:Irr-Meter
[2026-08-01 17:58:00.756 UTC] [V] 485ChCtl <C1> fixed cycle Irr-Meter
[2026-08-01 17:58:00.756 UTC] [V] 485DevCtl <C1:01> Dev not PCS IsNeedToChangeOControlState
[2026-08-01 17:58:00.756 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :1
[2026-08-01 17:58:00.757 UTC] [V] 485ChCtl <C1> send request:Irr01
[2026-08-01 17:58:00.758 UTC] [D] 485AcReq <C1:01> PutOStream [1][080001040000000271cb]
[2026-08-01 17:58:00.794 UTC] [V] 485DevCtl <C3:01> AnalyzeResponseData proc restart cnt:17960 UPRstat:0
[2026-08-01 17:58:00.798 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:58:00.799 UTC] [D] 485DevCtl <C3:01> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:58:00.799 UTC] [D] 485DevCtl <C3:01> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:58:00.799 UTC] [V] 485DevCtl <C3:01> device_type:Battery
[2026-08-01 17:58:00.799 UTC] [V] 485DevCtl <C3:02> AnalyzeResponseData proc restart cnt:17960 UPRstat:0
[2026-08-01 17:58:00.801 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:58:00.801 UTC] [D] 485DevCtl <C3:02> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:58:00.801 UTC] [D] 485DevCtl <C3:02> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:58:00.801 UTC] [V] 485DevCtl <C3:02> device_type:Battery
[2026-08-01 17:58:00.801 UTC] [V] 485DevCtl <C3:03> AnalyzeResponseData proc restart cnt:17960 UPRstat:0
[2026-08-01 17:58:00.842 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:58:00.842 UTC] [D] 485DevCtl <C3:03> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:58:00.842 UTC] [D] 485DevCtl <C3:03> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:58:00.843 UTC] [V] 485DevCtl <C3:03> device_type:Battery
[2026-08-01 17:58:00.843 UTC] [V] 485DevCtl <C3:04> AnalyzeResponseData proc restart cnt:17960 UPRstat:0
[2026-08-01 17:58:00.855 UTC] [V] OFSCtrl limit chk 400 < 800 < [1195->1195] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:00.855 UTC] [V] OFSCtrl angif value:1195 power_val_:21468.750000
[2026-08-01 17:58:00.863 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:58:00.863 UTC] [D] 485DevCtl <C3:04> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:58:00.864 UTC] [D] 485DevCtl <C3:04> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:58:00.864 UTC] [V] 485DevCtl <C3:04> device_type:Battery
[2026-08-01 17:58:00.869 UTC] [V] 485ChCtl <C3> set rt:0
[2026-08-01 17:58:00.955 UTC] [V] OFSCtrl limit chk 400 < 800 < [1195->1195] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:00.955 UTC] [V] OFSCtrl angif value:1195 power_val_:21468.750000
[2026-08-01 17:58:01.001 UTC] [D] 485DevCtl <C2:03> RcvDat status[2] len[9] [03040400100000d981]
[2026-08-01 17:58:01.001 UTC] [D] 485DevCtl <C2:03> ResCnd OperationId [2] IsNormal[0]  ConditionType [lggrdev:Error] Action[4]
[2026-08-01 17:58:01.001 UTC] [V] 485DevCtl <C2:03> device_type:PV-PCS
[2026-08-01 17:58:01.001 UTC] [V] 485DevCtl <C2:03> ExecuteAction name:RestartCounter value0
[2026-08-01 17:58:01.002 UTC] [V] 485DevCtl <C2:03> ExecuteAction set start cnt:0
[2026-08-01 17:58:01.003 UTC] [V] 485ChCtl <C2> set rt:0
[2026-08-01 17:58:01.013 UTC] [V] OFSCtrl [/var/local/solajithome/function/output_fluctuation_suppression/batt_data] write success.
[2026-08-01 17:58:01.055 UTC] [V] OFSCtrl limit chk 400 < 800 < [1195->1195] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:01.056 UTC] [V] OFSCtrl angif value:1195 power_val_:21468.750000
[2026-08-01 17:58:01.064 UTC] [V] 485ChCtl <C2> StartDeviceCommunicationForOutputFluctuationSuppressionControlBroadcast 4 cnt:179553, monitor_cnt:62, bc_elapsed:179553, min:10, max:40
[2026-08-01 17:58:01.064 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :4
[2026-08-01 17:58:01.065 UTC] [V] 485ChCtl <C2> send request:Sungrow08
[2026-08-01 17:58:01.066 UTC] [D] 485AcReq <C2:04> PutOStream [4][0800040413b40001753d]
[2026-08-01 17:58:01.095 UTC] [V] 485DevCtl <C1:01> AnalyzeResponseData proc restart cnt:17978 UPRstat:0
[2026-08-01 17:58:01.095 UTC] [V] Res no response condition. set normal condition.
[2026-08-01 17:58:01.095 UTC] [D] 485DevCtl <C1:01> RcvDat status[2] len[9] [010404000001fa7a57]
[2026-08-01 17:58:01.095 UTC] [D] 485DevCtl <C1:01> ResCnd OperationId [1] IsNormal[1] 
[2026-08-01 17:58:01.096 UTC] [V] OFSCtrl Rcv set flux_of_solar:0.000000
[2026-08-01 17:58:01.096 UTC] [V] 485DevCtl <C1:01> [01][401006][0.000000][1][W/m2]
[2026-08-01 17:58:01.096 UTC] [V] SummDat SetVrmValue dev_id:1 val:0.000000 sc:3
[2026-08-01 17:58:01.096 UTC] [V] OCMgr SetMeterValue PhId:0101, branchNo:01, valueId:401006, value:0.000000, scaleFactor:1, devId:1
[2026-08-01 17:58:01.097 UTC] [V] 485DevCtl <C1:01> [01][421005][256.000000][1][℃]
[2026-08-01 17:58:01.097 UTC] [V] SummDat SetVrmValue dev_id:1 val:25600.000000 sc:3
[2026-08-01 17:58:01.097 UTC] [V] OCMgr SetMeterValue PhId:0101, branchNo:01, valueId:421005, value:256.000000, scaleFactor:1, devId:1
[2026-08-01 17:58:01.097 UTC] [V] 485DevCtl <C1:01> device_type:Irr-Meter
[2026-08-01 17:58:01.097 UTC] [V] OFSCtrl Irr-Meter received.
[2026-08-01 17:58:01.098 UTC] [V] 485ChCtl <C1> set rt:0
[2026-08-01 17:58:01.102 UTC] [V] 485DevCtl <C1:01> device_type:Irr-Meter
[2026-08-01 17:58:01.155 UTC] [V] OFSCtrl limit chk 400 < 800 < [1195->1195] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:01.155 UTC] [V] OFSCtrl angif value:1195 power_val_:21468.750000
[2026-08-01 17:58:01.156 UTC] [V] 485DevCtl <C1:04> device_type:CO-Meter
[2026-08-01 17:58:01.156 UTC] [V] 485DevCtl <C1:04> device_type:CO-Meter
[2026-08-01 17:58:01.156 UTC] [V] 485ChCtl <C1> fixed cycle CO-Meter
[2026-08-01 17:58:01.156 UTC] [V] 485DevCtl <C1:04> Dev not PCS IsNeedToChangeOControlState
[2026-08-01 17:58:01.157 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :1
[2026-08-01 17:58:01.157 UTC] [V] 485ChCtl <C1> send request:omron05
[2026-08-01 17:58:01.158 UTC] [D] 485AcReq <C1:04> PutOStream [1][0800040300030014b590]
[2026-08-01 17:58:01.255 UTC] [V] OFSCtrl limit chk 400 < 800 < [1195->1195] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:01.255 UTC] [V] OFSCtrl angif value:1195 power_val_:21468.750000
[2026-08-01 17:58:01.355 UTC] [V] OFSCtrl limit chk 400 < 800 < [1195->1195] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:01.355 UTC] [V] OFSCtrl angif value:1195 power_val_:21468.750000
[2026-08-01 17:58:01.390 UTC] [D] 485DevCtl <C2:04> RcvDat status[2] len[7] [04040200007530]
[2026-08-01 17:58:01.390 UTC] [D] 485DevCtl <C2:04> ResCnd OperationId [4] IsNormal[0]  ConditionType [lggrdev:Error] Action[-1]
[2026-08-01 17:58:01.391 UTC] [V] 485DevCtl <C2:04> device_type:PV-PCS
[2026-08-01 17:58:01.401 UTC] [V] 485ChCtl <C2> set rt:0
[2026-08-01 17:58:01.455 UTC] [V] OFSCtrl limit chk 400 < 800 < [1195->1195] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:01.455 UTC] [V] OFSCtrl angif value:1195 power_val_:21468.750000
[2026-08-01 17:58:01.464 UTC] [V] 485ChCtl <C2> StartDeviceCommunicationForOutputFluctuationSuppressionControlBroadcast 4 cnt:179557, monitor_cnt:66, bc_elapsed:179557, min:10, max:40
[2026-08-01 17:58:01.464 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :1
[2026-08-01 17:58:01.465 UTC] [V] 485ChCtl <C2> send request:Sungrow08
[2026-08-01 17:58:01.465 UTC] [D] 485AcReq <C2:05> PutOStream [1][08000504138a0024d4fb]
[2026-08-01 17:58:01.555 UTC] [V] OFSCtrl limit chk 400 < 800 < [1195->1195] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:01.555 UTC] [V] OFSCtrl angif value:1195 power_val_:21468.750000
[2026-08-01 17:58:01.555 UTC] [V] OFSCtrl Control charge discharge proc start.
[2026-08-01 17:58:01.555 UTC] [V] OFSCtrl CHG 20 p_th(t):21224.550000 = p_th_old_:21254.250000 + lev_cd_:-0.300000 * (total_pcs_capacity_:297000.000000 * cof_spec_:2.000000 / 60 * (time_threshold_renew:10.000000 * 10)), min:-2062.500000, max:407900.000000
[2026-08-01 17:58:01.556 UTC] [V] OFSCtrl CHG 21 batt_w:21787.454579 = old:21922.952579 +  kp:0.550000 * e:-244.200000 + ki:0.000000 * sume:-12205.049857 + kd:0.040000 * (e:-244.200000 - e1:-214.500000)
[2026-08-01 17:58:01.556 UTC] [V] OFSCtrl CHG 21 battery threshold min:20000.000000 <= bat:21787.454579 <= max:196000.000000, adjust charge:0.000000, discharge:1000.000000
[2026-08-01 17:58:01.556 UTC] [V] OFSCtrl CHG 29 q:54.000000, mod(round):2.000000
[2026-08-01 17:58:01.557 UTC] [V] OFSCtrl discharge bat_w[0303]:6500.000000 += adjust:1000.000000
[2026-08-01 17:58:01.558 UTC] [D] OFSCtrl battery ctrl val:10.900000
[2026-08-01 17:58:01.558 UTC] [V] 485ChCtl <C3> battery limit on [54.000000,55.000000,65.000000,54.000000,] request.
[2026-08-01 17:58:01.558 UTC] [V] OFSCtrl Control charge discharge proc:01->02->BATT_CHK->03->04->05->06->10->12->13->15->16->18->19->20->21->22->23->24->25->27->23->24->25->27->23->24->25->27->23->24->25->27->28->29->30->31->32->30->31->32->30->31->32->30->31->32->33->34
[2026-08-01 17:58:01.564 UTC] [V] 485DevCtl <C1:04> AnalyzeResponseData proc restart cnt:17978 UPRstat:0
[2026-08-01 17:58:01.564 UTC] [V] Res no response condition. set normal condition.
[2026-08-01 17:58:01.565 UTC] [D] 485DevCtl <C1:04> RcvDat status[2] len[45] [0403280000f53b0000fc640000e47f000000640000025800034c3d00000871ffffbee7ffffff5a00233b02d8bc]
[2026-08-01 17:58:01.565 UTC] [D] 485DevCtl <C1:04> ResCnd OperationId [1] IsNormal[1] 
[2026-08-01 17:58:01.566 UTC] [V] OFSCtrl Rcv set p_co:21610.000000, p_co_old:21560.000000
[2026-08-01 17:58:01.566 UTC] [V] 485DevCtl <C1:04> [01][601260][2161.000000][2][kW]
[2026-08-01 17:58:01.566 UTC] [V] SummDat SetVrmValue dev_id:4 val:21610.000000 sc:3
[2026-08-01 17:58:01.566 UTC] [V] OCMgr SetMeterValue PhId:0104, branchNo:01, valueId:601260, value:2161.000000, scaleFactor:2, devId:4
[2026-08-01 17:58:01.567 UTC] [V] 485DevCtl <C1:04> [01][603260][2308866.000000][1][kWh]
[2026-08-01 17:58:01.567 UTC] [V] SummDat SetVrmValue dev_id:4 val:2308866.000000 sc:1
[2026-08-01 17:58:01.567 UTC] [V] OCMgr SetMeterValue PhId:0104, branchNo:01, valueId:603260, value:2308866.000000, scaleFactor:1, devId:4
[2026-08-01 17:58:01.575 UTC] [V] 485DevCtl <C1:04> device_type:CO-Meter
[2026-08-01 17:58:01.576 UTC] [V] OFSCtrl km50 received.
[2026-08-01 17:58:01.578 UTC] [V] 485ChCtl <C3> battery send request.1
[2026-08-01 17:58:01.579 UTC] [D] VarInf Limit_Bat rt[2]set val[54] set rate[10.800000] value100[500] value-100[-500]
[2026-08-01 17:58:01.580 UTC] [D] VarInf Limit_Bat rt[2]set val[55] set rate[11.000000] value100[500] value-100[-500]
[2026-08-01 17:58:01.582 UTC] [D] VarInf Limit_Bat rt[2]set val[65] set rate[13.000000] value100[500] value-100[-500]
[2026-08-01 17:58:01.583 UTC] [D] VarInf Limit_Bat rt[2]set val[54] set rate[10.800000] value100[500] value-100[-500]
[2026-08-01 17:58:01.578 UTC] [V] OFSCtrl omron05_local_date :2026/08/02 ? 2026/08/02
[2026-08-01 17:58:01.585 UTC] [V] OFSCtrl omron05_local_time :2026/08/02 02 ? 2026/08/02 02
[2026-08-01 17:58:01.590 UTC] [V] OFSCtrl out of control time.
[2026-08-01 17:58:01.590 UTC] [V] OFSCtrl Control pv-pcs proc start.
[2026-08-01 17:58:01.590 UTC] [V] OFSCtrl NOD_month:-445.000000 = (NOD_month:13 - ((nod_max_/30):23.333333 * (cnt-1):12) * (30/cnt):1.666667 
[2026-08-01 17:58:01.590 UTC] [V] OFSCtrl PCS ratio_month:113.496241 = -k_inhibition_ratio_month:-0.097744 * NOD_month:-445.000000 + inhibition_ratio_max:70
[2026-08-01 17:58:01.590 UTC] [V] OFSCtrl PCS 05 inhibition_ratio:70.000000 = max(ratio_min:5, min(ratio:70, ratio_hour:70.000000, ratio_day:70.000000, ratio_month:113.496241))
[2026-08-01 17:58:01.591 UTC] [D] OFSCtrl pv-pcs ctrl val:0.000000 old:0.000000
[2026-08-01 17:58:01.591 UTC] [V] OCHisDB set rate:0 t_rate:0 cnt:33
[2026-08-01 17:58:01.591 UTC] [V] 485ChCtl <C2> pv-pcs limit on [0.000000] request.
[2026-08-01 17:58:01.596 UTC] [D] 485AcReq <C3:01> PutOStream [6][0f000001000000090110278e0001020036]
[2026-08-01 17:58:01.596 UTC] [D] 485AcReq <C3:02> PutOStream [6][0f000001000000090110278e0001020037]
[2026-08-01 17:58:01.597 UTC] [D] 485AcReq <C3:03> PutOStream [6][0f000001000000090110278e0001020041]
[2026-08-01 17:58:01.597 UTC] [D] 485AcReq <C3:04> PutOStream [6][0f000001000000090110278e0001020036]
[2026-08-01 17:58:01.591 UTC] [V] OFSCtrl Control pv-pcs proc:BATT_CHK->01->02->03->04->05->06->07->09->09->10->11->12
[2026-08-01 17:58:01.610 UTC] [V] 485ChCtl <C1> set rt:0
[2026-08-01 17:58:01.611 UTC] [V] 485DevCtl <C1:04> device_type:CO-Meter
[2026-08-01 17:58:01.655 UTC] [V] OFSCtrl limit chk 400 < 800 < [1195->1195] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:01.655 UTC] [V] OFSCtrl angif value:1195 power_val_:21468.750000
[2026-08-01 17:58:01.755 UTC] [V] OFSCtrl limit chk 400 < 800 < [1195->1195] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:01.755 UTC] [V] OFSCtrl angif value:1195 power_val_:21468.750000
[2026-08-01 17:58:01.794 UTC] [V] 485DevCtl <C3:01> AnalyzeResponseData proc restart cnt:17961 UPRstat:0
[2026-08-01 17:58:01.799 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:58:01.799 UTC] [D] 485DevCtl <C3:01> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:58:01.799 UTC] [D] 485DevCtl <C3:01> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:58:01.799 UTC] [V] 485DevCtl <C3:01> device_type:Battery
[2026-08-01 17:58:01.800 UTC] [V] 485DevCtl <C3:02> AnalyzeResponseData proc restart cnt:17961 UPRstat:0
[2026-08-01 17:58:01.816 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:58:01.822 UTC] [D] 485DevCtl <C3:02> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:58:01.822 UTC] [D] 485DevCtl <C3:02> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:58:01.823 UTC] [V] 485DevCtl <C3:02> device_type:Battery
[2026-08-01 17:58:01.831 UTC] [V] 485DevCtl <C3:03> AnalyzeResponseData proc restart cnt:17961 UPRstat:0
[2026-08-01 17:58:01.850 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:58:01.855 UTC] [V] OFSCtrl limit chk 400 < 800 < [1195->1195] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:01.855 UTC] [V] OFSCtrl angif value:1195 power_val_:21468.750000
[2026-08-01 17:58:01.850 UTC] [D] 485DevCtl <C3:03> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:58:01.856 UTC] [D] 485DevCtl <C3:03> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:58:01.863 UTC] [V] Res no response condition. set normal condition.
[2026-08-01 17:58:01.866 UTC] [D] 485DevCtl <C2:05> RcvDat status[2] len[77] [0504480000bb6f0000112f000000000000000000000000000000000000000000000000000000000000000000000000ffffffffffffffffffffffff0000000000000000000000000000140020c2]
[2026-08-01 17:58:01.866 UTC] [D] 485DevCtl <C2:05> ResCnd OperationId [1] IsNormal[1] 
[2026-08-01 17:58:01.866 UTC] [V] 485DevCtl <C2:05> [01][115202][0.000000][1][kWh]
[2026-08-01 17:58:01.867 UTC] [V] SummDat SetVrmValue dev_id:11 val:0.000000 sc:1
[2026-08-01 17:58:01.867 UTC] [V] OCMgr SetMeterValue PhId:0205, branchNo:01, valueId:115202, value:0.000000, scaleFactor:1, devId:11
[2026-08-01 17:58:01.867 UTC] [V] 485DevCtl <C2:05> [01][113202][47983.000000][0][kWh]
[2026-08-01 17:58:01.867 UTC] [V] SummDat SetVrmValue dev_id:11 val:47983.000000 sc:0
[2026-08-01 17:58:01.867 UTC] [V] OCMgr SetMeterValue PhId:0205, branchNo:01, valueId:113202, value:47983.000000, scaleFactor:0, devId:11
[2026-08-01 17:58:01.868 UTC] [V] 485DevCtl <C2:05> [01][121005][0.000000][1][℃]
[2026-08-01 17:58:01.868 UTC] [V] SummDat SetVrmValue dev_id:11 val:0.000000 sc:3
[2026-08-01 17:58:01.868 UTC] [V] OCMgr SetMeterValue PhId:0205, branchNo:01, valueId:121005, value:0.000000, scaleFactor:1, devId:11
[2026-08-01 17:58:01.868 UTC] [V] 485DevCtl <C2:05> [01][101100][0.000000][1][V]
[2026-08-01 17:58:01.868 UTC] [V] SummDat SetVrmValue dev_id:11 val:0.000000 sc:3
[2026-08-01 17:58:01.869 UTC] [V] OCMgr SetMeterValue PhId:0205, branchNo:01, valueId:101100, value:0.000000, scaleFactor:1, devId:11
[2026-08-01 17:58:01.869 UTC] [V] 485DevCtl <C3:03> device_type:Battery
[2026-08-01 17:58:01.873 UTC] [V] 485DevCtl <C3:04> AnalyzeResponseData proc restart cnt:17961 UPRstat:0
[2026-08-01 17:58:01.885 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:58:01.889 UTC] [D] 485DevCtl <C3:04> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:58:01.890 UTC] [D] 485DevCtl <C3:04> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:58:01.890 UTC] [V] 485DevCtl <C3:04> device_type:Battery
[2026-08-01 17:58:01.890 UTC] [V] 485ChCtl <C3> set rt:0
[2026-08-01 17:58:01.892 UTC] [V] 485DevCtl <C2:05> [01][101101][0.000000][1][A]
[2026-08-01 17:58:01.892 UTC] [V] SummDat SetVrmValue dev_id:11 val:0.000000 sc:3
[2026-08-01 17:58:01.892 UTC] [V] OCMgr SetMeterValue PhId:0205, branchNo:01, valueId:101101, value:0.000000, scaleFactor:1, devId:11
[2026-08-01 17:58:01.893 UTC] [V] 485DevCtl <C2:05> [02][101100][0.000000][1][V]
[2026-08-01 17:58:01.893 UTC] [V] SummDat SetVrmValue dev_id:11 val:0.000000 sc:3
[2026-08-01 17:58:01.893 UTC] [V] OCMgr SetMeterValue PhId:0205, branchNo:02, valueId:101100, value:0.000000, scaleFactor:1, devId:11
[2026-08-01 17:58:01.894 UTC] [V] 485DevCtl <C2:05> [02][101101][0.000000][1][A]
[2026-08-01 17:58:01.894 UTC] [V] SummDat SetVrmValue dev_id:11 val:0.000000 sc:3
[2026-08-01 17:58:01.894 UTC] [V] OCMgr SetMeterValue PhId:0205, branchNo:02, valueId:101101, value:0.000000, scaleFactor:1, devId:11
[2026-08-01 17:58:01.904 UTC] [V] 485DevCtl <C2:05> [03][101100][0.000000][1][V]
[2026-08-01 17:58:01.906 UTC] [V] SummDat SetVrmValue dev_id:11 val:0.000000 sc:3
[2026-08-01 17:58:01.911 UTC] [V] OCMgr SetMeterValue PhId:0205, branchNo:03, valueId:101100, value:0.000000, scaleFactor:1, devId:11
[2026-08-01 17:58:01.915 UTC] [V] 485DevCtl <C2:05> [03][101101][0.000000][1][A]
[2026-08-01 17:58:01.916 UTC] [V] SummDat SetVrmValue dev_id:11 val:0.000000 sc:3
[2026-08-01 17:58:01.921 UTC] [V] OCMgr SetMeterValue PhId:0205, branchNo:03, valueId:101101, value:0.000000, scaleFactor:1, devId:11
[2026-08-01 17:58:01.924 UTC] [V] 485DevCtl <C2:05> [01][101102][0.000000][0][W]
[2026-08-01 17:58:01.925 UTC] [V] SummDat SetVrmValue dev_id:11 val:0.000000 sc:3
[2026-08-01 17:58:01.930 UTC] [V] OCMgr SetMeterValue PhId:0205, branchNo:01, valueId:101102, value:0.000000, scaleFactor:0, devId:11
[2026-08-01 17:58:01.932 UTC] [V] 485DevCtl <C2:05> [01][111200][0.000000][1][V]
[2026-08-01 17:58:01.932 UTC] [V] SummDat SetVrmValue dev_id:11 val:0.000000 sc:3
[2026-08-01 17:58:01.934 UTC] [V] OCMgr SetMeterValue PhId:0205, branchNo:01, valueId:111200, value:0.000000, scaleFactor:1, devId:11
[2026-08-01 17:58:01.936 UTC] [V] 485DevCtl <C2:05> [02][111200][0.000000][1][V]
[2026-08-01 17:58:01.938 UTC] [V] SummDat SetVrmValue dev_id:11 val:0.000000 sc:3
[2026-08-01 17:58:01.943 UTC] [V] OCMgr SetMeterValue PhId:0205, branchNo:02, valueId:111200, value:0.000000, scaleFactor:1, devId:11
[2026-08-01 17:58:01.947 UTC] [V] 485DevCtl <C2:05> [03][111200][0.000000][1][V]
[2026-08-01 17:58:01.949 UTC] [V] SummDat SetVrmValue dev_id:11 val:0.000000 sc:3
[2026-08-01 17:58:01.955 UTC] [V] OFSCtrl limit chk 400 < 800 < [1195->1195] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:01.955 UTC] [V] OFSCtrl angif value:1195 power_val_:21468.750000
[2026-08-01 17:58:01.954 UTC] [V] OCMgr SetMeterValue PhId:0205, branchNo:03, valueId:111200, value:0.000000, scaleFactor:1, devId:11
[2026-08-01 17:58:01.960 UTC] [V] 485DevCtl <C2:05> [01][111201][0.000000][1][A]
[2026-08-01 17:58:01.960 UTC] [V] SummDat SetVrmValue dev_id:11 val:0.000000 sc:3
[2026-08-01 17:58:01.960 UTC] [V] OCMgr SetMeterValue PhId:0205, branchNo:01, valueId:111201, value:0.000000, scaleFactor:1, devId:11
[2026-08-01 17:58:01.960 UTC] [V] 485DevCtl <C2:05> [02][111201][0.000000][1][A]
[2026-08-01 17:58:01.961 UTC] [V] SummDat SetVrmValue dev_id:11 val:0.000000 sc:3
[2026-08-01 17:58:01.961 UTC] [V] OCMgr SetMeterValue PhId:0205, branchNo:02, valueId:111201, value:0.000000, scaleFactor:1, devId:11
[2026-08-01 17:58:01.961 UTC] [V] 485DevCtl <C2:05> [03][111201][0.000000][1][A]
[2026-08-01 17:58:01.961 UTC] [V] SummDat SetVrmValue dev_id:11 val:0.000000 sc:3
[2026-08-01 17:58:01.961 UTC] [V] OCMgr SetMeterValue PhId:0205, branchNo:03, valueId:111201, value:0.000000, scaleFactor:1, devId:11
[2026-08-01 17:58:01.968 UTC] [V] 485DevCtl <C2:05> [01][111202][0.000000][0][W]
[2026-08-01 17:58:01.970 UTC] [V] SummDat SetVrmValue dev_id:11 val:0.000000 sc:3
[2026-08-01 17:58:01.975 UTC] [V] OCMgr SetMeterValue PhId:0205, branchNo:01, valueId:111202, value:0.000000, scaleFactor:0, devId:11
[2026-08-01 17:58:01.978 UTC] [V] 485DevCtl <C2:05> [01][111203][0.000000][0][var]
[2026-08-01 17:58:01.980 UTC] [V] SummDat SetVrmValue dev_id:11 val:0.000000 sc:3
[2026-08-01 17:58:01.984 UTC] [V] OCMgr SetMeterValue PhId:0205, branchNo:01, valueId:111203, value:0.000000, scaleFactor:0, devId:11
[2026-08-01 17:58:01.988 UTC] [V] 485DevCtl <C2:05> [01][121007][0.000000][3][]
[2026-08-01 17:58:01.989 UTC] [V] SummDat SetVrmValue dev_id:11 val:0.000000 sc:3
[2026-08-01 17:58:01.993 UTC] [V] OCMgr SetMeterValue PhId:0205, branchNo:01, valueId:121007, value:0.000000, scaleFactor:3, devId:11
[2026-08-01 17:58:01.998 UTC] [V] 485DevCtl <C2:05> [01][131006][0.000000][1][Hz]
[2026-08-01 17:58:01.999 UTC] [V] SummDat SetVrmValue dev_id:11 val:0.000000 sc:3
[2026-08-01 17:58:02.000 UTC] [V] OCMgr SetMeterValue PhId:0205, branchNo:01, valueId:131006, value:0.000000, scaleFactor:1, devId:11
[2026-08-01 17:58:02.001 UTC] [V] 485DevCtl <C2:05> [01][114202][47983.000000][0][kWh]
[2026-08-01 17:58:02.001 UTC] [V] SummDat SetVrmValue dev_id:11 val:47983000.000000 sc:3
[2026-08-01 17:58:02.001 UTC] [V] OCMgr SetMeterValue PhId:0205, branchNo:01, valueId:114202, value:47983.000000, scaleFactor:0, devId:11
[2026-08-01 17:58:02.001 UTC] [V] 485DevCtl <C2:05> device_type:PV-PCS
[2026-08-01 17:58:02.010 UTC] [V] 485DevCtl <C2:05> set2 StatusCode[010100] DeviceName[] DeviceNumber[]
[2026-08-01 17:58:02.012 UTC] [V] OFSCtrl [/var/local/solajithome/function/output_fluctuation_suppression/batt_data] write success.
[2026-08-01 17:58:02.016 UTC] [V] 485ChCtl <C2> set rt:0
[2026-08-01 17:58:02.055 UTC] [V] OFSCtrl limit chk 400 < 800 < [1195->1195] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:02.055 UTC] [V] OFSCtrl angif value:1195 power_val_:21468.750000
[2026-08-01 17:58:02.064 UTC] [V] 485ChCtl <C2> pv-pcs send request.
[2026-08-01 17:58:02.064 UTC] [D] VarInf update ofs_rate:0.000000
[2026-08-01 17:58:02.064 UTC] [V] VarInf LimitSet rt[2] val[170] key[ValueOn]
[2026-08-01 17:58:02.064 UTC] [D] VarInf output_mode:8
[2026-08-01 17:58:02.065 UTC] [D] VarInf update ofs_rate:0.000000
[2026-08-01 17:58:02.065 UTC] [D] VarInf Limit setRate[0.000000] rate[0.000000] value100[1000.000000] value0[0.000000]
[2026-08-01 17:58:02.065 UTC] [V] 485DevCtl <C2:01> ChangeOutputRateToDevice rate:0.000000 set_rate1
[2026-08-01 17:58:02.065 UTC] [D] VarInf Limit rt[2] int_set_rate[1] server_rate[0.000000] rated_output[100.000000] solar_battery_power[100.000000]
[2026-08-01 17:58:02.066 UTC] [D] 485AcReq <C2:01> PutOStreamForBc [3][0d000010138e00020400aa0001466f]
[2026-08-01 17:58:02.155 UTC] [V] OFSCtrl limit chk 400 < 800 < [1195->1195] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:02.155 UTC] [V] OFSCtrl angif value:1195 power_val_:21468.750000
[2026-08-01 17:58:02.255 UTC] [V] OFSCtrl limit chk 400 < 800 < [1195->1195] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:02.255 UTC] [V] OFSCtrl angif value:1195 power_val_:21468.750000
[2026-08-01 17:58:02.356 UTC] [V] OFSCtrl limit chk 400 < 800 < [1195->1195] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:02.356 UTC] [V] OFSCtrl angif value:1195 power_val_:21468.750000
[2026-08-01 17:58:02.358 UTC] [V] 485ChCtl <C2> set rt:0
[2026-08-01 17:58:02.364 UTC] [V] 485ChCtl <C2> StartDeviceCommunicationForOutputFluctuationSuppressionControlBroadcast 4 cnt:179566, monitor_cnt:75, bc_elapsed:179566, min:10, max:40
[2026-08-01 17:58:02.365 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :2
[2026-08-01 17:58:02.365 UTC] [V] 485ChCtl <C2> send request:Sungrow08
[2026-08-01 17:58:02.366 UTC] [D] 485AcReq <C2:06> PutOStream [2][0800060413d80002f4c3]
[2026-08-01 17:58:02.455 UTC] [V] OFSCtrl limit chk 400 < 800 < [1195->1195] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:02.456 UTC] [V] OFSCtrl angif value:1195 power_val_:21468.750000
[2026-08-01 17:58:02.555 UTC] [V] OFSCtrl limit chk 400 < 800 < [1195->1195] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:02.555 UTC] [V] OFSCtrl angif value:1195 power_val_:21468.750000
[2026-08-01 17:58:02.555 UTC] [V] OFSCtrl Control charge discharge proc start.
[2026-08-01 17:58:02.558 UTC] [V] OFSCtrl CHG 20 p_th(t):21194.850000 = p_th_old_:21224.550000 + lev_cd_:-0.300000 * (total_pcs_capacity_:297000.000000 * cof_spec_:2.000000 / 60 * (time_threshold_renew:10.000000 * 10)), min:-2062.500000, max:407900.000000
[2026-08-01 17:58:02.559 UTC] [V] OFSCtrl CHG 21 batt_w:21635.621579 = old:21787.454579 +  kp:0.550000 * e:-273.900000 + ki:0.000000 * sume:-12478.949857 + kd:0.040000 * (e:-273.900000 - e1:-244.200000)
[2026-08-01 17:58:02.560 UTC] [V] OFSCtrl CHG 21 battery threshold min:20000.000000 <= bat:21635.621579 <= max:196000.000000, adjust charge:0.000000, discharge:1000.000000
[2026-08-01 17:58:02.561 UTC] [V] OFSCtrl CHG 29 q:54.000000, mod(round):0.000000
[2026-08-01 17:58:02.562 UTC] [V] OFSCtrl discharge bat_w[0303]:6400.000000 += adjust:1000.000000
[2026-08-01 17:58:02.562 UTC] [D] OFSCtrl battery ctrl val:10.800000
[2026-08-01 17:58:02.564 UTC] [V] 485ChCtl <C3> battery limit on [54.000000,54.000000,64.000000,54.000000,] request.
[2026-08-01 17:58:02.567 UTC] [V] OFSCtrl Control charge discharge proc:01->02->BATT_CHK->03->04->05->06->10->12->13->15->16->18->19->20->21->22->23->24->25->27->23->24->25->27->23->24->25->27->23->24->25->27->28->29->30->31->32->30->31->32->30->31->32->30->31->32->33->34
[2026-08-01 17:58:02.579 UTC] [V] 485ChCtl <C3> battery send request.1
[2026-08-01 17:58:02.580 UTC] [D] VarInf Limit_Bat rt[2]set val[54] set rate[10.800000] value100[500] value-100[-500]
[2026-08-01 17:58:02.581 UTC] [D] VarInf Limit_Bat rt[2]set val[54] set rate[10.800000] value100[500] value-100[-500]
[2026-08-01 17:58:02.584 UTC] [D] VarInf Limit_Bat rt[2]set val[64] set rate[12.800000] value100[500] value-100[-500]
[2026-08-01 17:58:02.611 UTC] [D] VarInf Limit_Bat rt[2]set val[54] set rate[10.800000] value100[500] value-100[-500]
[2026-08-01 17:58:02.621 UTC] [D] 485AcReq <C3:01> PutOStream [6][0f000001000000090110278e0001020036]
[2026-08-01 17:58:02.622 UTC] [D] 485AcReq <C3:02> PutOStream [6][0f000001000000090110278e0001020036]
[2026-08-01 17:58:02.622 UTC] [D] 485AcReq <C3:03> PutOStream [6][0f000001000000090110278e0001020040]
[2026-08-01 17:58:02.623 UTC] [D] 485AcReq <C3:04> PutOStream [6][0f000001000000090110278e0001020036]
[2026-08-01 17:58:02.655 UTC] [V] OFSCtrl limit chk 400 < 800 < [1195->1195] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:02.655 UTC] [V] OFSCtrl angif value:1195 power_val_:21468.750000
[2026-08-01 17:58:02.696 UTC] [D] 485DevCtl <C2:06> RcvDat status[2] len[9] [060404001000008c81]
[2026-08-01 17:58:02.696 UTC] [D] 485DevCtl <C2:06> ResCnd OperationId [2] IsNormal[0]  ConditionType [lggrdev:Error] Action[4]
[2026-08-01 17:58:02.699 UTC] [V] 485DevCtl <C2:06> device_type:PV-PCS
[2026-08-01 17:58:02.699 UTC] [V] 485DevCtl <C2:06> ExecuteAction name:RestartCounter value0
[2026-08-01 17:58:02.699 UTC] [V] 485DevCtl <C2:06> ExecuteAction set start cnt:0
[2026-08-01 17:58:02.700 UTC] [V] 485ChCtl <C2> set rt:0
[2026-08-01 17:58:02.701 UTC] [D] 485ChCtl <C2> monitoring dev All Send
[2026-08-01 17:58:02.755 UTC] [V] OFSCtrl limit chk 400 < 800 < [1195->1195] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:02.755 UTC] [V] OFSCtrl angif value:1195 power_val_:21468.750000
[2026-08-01 17:58:02.794 UTC] [V] 485DevCtl <C3:01> AnalyzeResponseData proc restart cnt:17962 UPRstat:0
[2026-08-01 17:58:02.799 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:58:02.799 UTC] [D] 485DevCtl <C3:01> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:58:02.799 UTC] [D] 485DevCtl <C3:01> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:58:02.799 UTC] [V] 485DevCtl <C3:01> device_type:Battery
[2026-08-01 17:58:02.800 UTC] [V] 485DevCtl <C3:02> AnalyzeResponseData proc restart cnt:17962 UPRstat:0
[2026-08-01 17:58:02.801 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:58:02.801 UTC] [D] 485DevCtl <C3:02> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:58:02.802 UTC] [D] 485DevCtl <C3:02> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:58:02.802 UTC] [V] 485DevCtl <C3:02> device_type:Battery
[2026-08-01 17:58:02.825 UTC] [V] 485DevCtl <C3:03> AnalyzeResponseData proc restart cnt:17962 UPRstat:0
[2026-08-01 17:58:02.827 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:58:02.827 UTC] [D] 485DevCtl <C3:03> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:58:02.827 UTC] [D] 485DevCtl <C3:03> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:58:02.827 UTC] [V] 485DevCtl <C3:03> device_type:Battery
[2026-08-01 17:58:02.855 UTC] [V] OFSCtrl limit chk 400 < 800 < [1195->1195] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:02.855 UTC] [V] OFSCtrl angif value:1195 power_val_:21468.750000
[2026-08-01 17:58:02.858 UTC] [V] 485DevCtl <C3:04> AnalyzeResponseData proc restart cnt:17962 UPRstat:0
[2026-08-01 17:58:02.860 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:58:02.860 UTC] [D] 485DevCtl <C3:04> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:58:02.860 UTC] [D] 485DevCtl <C3:04> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:58:02.860 UTC] [V] 485DevCtl <C3:04> device_type:Battery
[2026-08-01 17:58:02.860 UTC] [V] 485ChCtl <C3> set rt:0
[2026-08-01 17:58:02.955 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:02.955 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:58:02.978 UTC] [V] 485ChCtl <C3> StartDeviceCommunicationForOutputFluctuationSuppressionControlBroadcast 4 cnt:179572, monitor_cnt:51, bc_elapsed:179572, min:10, max:40
[2026-08-01 17:58:02.979 UTC] [V] OFSCtrl /var/local/solajithome/function/output_fluctuation_suppression/state is exist:0
[2026-08-01 17:58:02.979 UTC] [V] 485DevCtl <C3:01> Dev not PCS IsNeedToChangeOControlState
[2026-08-01 17:58:02.979 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :5
[2026-08-01 17:58:02.980 UTC] [V] 485ChCtl <C3> send request:Sungrow11
[2026-08-01 17:58:02.981 UTC] [D] 485AcReq <C3:01> PutOStream [5][0c00000100000006010469780001]
[2026-08-01 17:58:03.012 UTC] [V] OFSCtrl [/var/local/solajithome/function/output_fluctuation_suppression/batt_data] write success.
[2026-08-01 17:58:03.055 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:03.055 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:58:03.103 UTC] [V] 485DevCtl <C3:01> AnalyzeResponseData proc restart cnt:17962 UPRstat:0
[2026-08-01 17:58:03.106 UTC] [D] 485DevCtl <C3:01> RcvDat status[0] len[11] [000100000005010402011f]
[2026-08-01 17:58:03.106 UTC] [D] 485DevCtl <C3:01> ResCnd OperationId [5] IsNormal[1]  ConditionType [lggrdev:Normal] Action[-1]
[2026-08-01 17:58:03.106 UTC] [V] 485DevCtl <C3:01> [01][121005][287.000000][1][℃]
[2026-08-01 17:58:03.107 UTC] [V] SummDat SetVrmValue dev_id:13 val:28700.000000 sc:3
[2026-08-01 17:58:03.107 UTC] [V] OCMgr SetMeterValue PhId:0301, branchNo:01, valueId:121005, value:287.000000, scaleFactor:1, devId:13
[2026-08-01 17:58:03.107 UTC] [V] 485DevCtl <C3:01> device_type:Battery
[2026-08-01 17:58:03.111 UTC] [V] 485ChCtl <C3> set rt:0
[2026-08-01 17:58:03.156 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:03.156 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:58:03.179 UTC] [V] 485ChCtl <C3> StartDeviceCommunicationForOutputFluctuationSuppressionControlBroadcast 4 cnt:179574, monitor_cnt:53, bc_elapsed:179574, min:10, max:40
[2026-08-01 17:58:03.179 UTC] [V] 485DevCtl <C3:02> Dev not PCS IsNeedToChangeOControlState
[2026-08-01 17:58:03.179 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :2
[2026-08-01 17:58:03.180 UTC] [V] 485ChCtl <C3> send request:Sungrow11
[2026-08-01 17:58:03.181 UTC] [D] 485AcReq <C3:02> PutOStream [2][0c0000010000000601042751005e]
[2026-08-01 17:58:03.255 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:03.256 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:58:03.333 UTC] [V] 485DevCtl <C3:02> AnalyzeResponseData proc restart cnt:17962 UPRstat:0
[2026-08-01 17:58:03.355 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:03.355 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:58:03.368 UTC] [D] 485DevCtl <C3:02> RcvDat status[0] len[197] [0001000000bf0104bc0000ffffffffffff035c00000000001000000000000000000000000000000000000000ae0032009a0000000100010001ffffffffffffffffffffffffffffffffffffffff000100000001000000010000ffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffff000101f40000003600000000000003e86fb6000065b600000000000000af0000]
[2026-08-01 17:58:03.368 UTC] [D] 485DevCtl <C3:02> ResCnd OperationId [2] IsNormal[1]  ConditionType [lggrdev:Normal] Action[-1]
[2026-08-01 17:58:03.368 UTC] [V] 485DevCtl <C3:02> [02][753049][0.000000][0][]
[2026-08-01 17:58:03.368 UTC] [V] SummDat SetVrmValue dev_id:14 val:0.000000 sc:0
[2026-08-01 17:58:03.369 UTC] [V] OCMgr SetMeterValue PhId:0302, branchNo:02, valueId:753049, value:0.000000, scaleFactor:0, devId:14
[2026-08-01 17:58:03.369 UTC] [V] 485DevCtl <C3:02> [01][753040][16.000000][0][]
[2026-08-01 17:58:03.369 UTC] [V] SummDat SetVrmValue dev_id:14 val:16.000000 sc:0
[2026-08-01 17:58:03.397 UTC] [V] OCMgr SetMeterValue PhId:0302, branchNo:01, valueId:753040, value:16.000000, scaleFactor:0, devId:14
[2026-08-01 17:58:03.397 UTC] [V] 485DevCtl <C3:02> [01][753053][0.000000][0][]
[2026-08-01 17:58:03.397 UTC] [V] SummDat SetVrmValue dev_id:14 val:0.000000 sc:0
[2026-08-01 17:58:03.397 UTC] [V] OCMgr SetMeterValue PhId:0302, branchNo:01, valueId:753053, value:0.000000, scaleFactor:0, devId:14
[2026-08-01 17:58:03.398 UTC] [V] 485DevCtl <C3:02> [02][753053][0.000000][0][]
[2026-08-01 17:58:03.398 UTC] [V] SummDat SetVrmValue dev_id:14 val:0.000000 sc:0
[2026-08-01 17:58:03.398 UTC] [V] OCMgr SetMeterValue PhId:0302, branchNo:02, valueId:753053, value:0.000000, scaleFactor:0, devId:14
[2026-08-01 17:58:03.398 UTC] [V] 485DevCtl <C3:02> [03][753053][0.000000][0][]
[2026-08-01 17:58:03.398 UTC] [V] SummDat SetVrmValue dev_id:14 val:0.000000 sc:0
[2026-08-01 17:58:03.399 UTC] [V] OCMgr SetMeterValue PhId:0302, branchNo:03, valueId:753053, value:0.000000, scaleFactor:0, devId:14
[2026-08-01 17:58:03.399 UTC] [V] 485DevCtl <C3:02> [04][753053][0.000000][0][]
[2026-08-01 17:58:03.399 UTC] [V] SummDat SetVrmValue dev_id:14 val:0.000000 sc:0
[2026-08-01 17:58:03.399 UTC] [V] OCMgr SetMeterValue PhId:0302, branchNo:04, valueId:753053, value:0.000000, scaleFactor:0, devId:14
[2026-08-01 17:58:03.400 UTC] [V] 485DevCtl <C3:02> [01][716202][500.000000][1][kW]
[2026-08-01 17:58:03.400 UTC] [V] SummDat SetVrmValue dev_id:14 val:50000.000000 sc:3
[2026-08-01 17:58:03.400 UTC] [V] OCMgr SetMeterValue PhId:0302, branchNo:01, valueId:716202, value:500.000000, scaleFactor:1, devId:14
[2026-08-01 17:58:03.400 UTC] [V] 485DevCtl <C3:02> [01][711102][54.000000][1][kW]
[2026-08-01 17:58:03.400 UTC] [V] SummDat SetVrmValue dev_id:14 val:5400.000000 sc:3
[2026-08-01 17:58:03.401 UTC] [V] OCMgr SetMeterValue PhId:0302, branchNo:01, valueId:711102, value:54.000000, scaleFactor:1, devId:14
[2026-08-01 17:58:03.401 UTC] [V] 485DevCtl <C3:02> [01][703102][28598.000000][0][kWh]
[2026-08-01 17:58:03.401 UTC] [V] SummDat SetVrmValue dev_id:14 val:28598.000000 sc:0
[2026-08-01 17:58:03.401 UTC] [V] OCMgr SetMeterValue PhId:0302, branchNo:01, valueId:703102, value:28598.000000, scaleFactor:0, devId:14
[2026-08-01 17:58:03.401 UTC] [V] 485DevCtl <C3:02> [01][713102][26038.000000][0][kWh]
[2026-08-01 17:58:03.401 UTC] [V] SummDat SetVrmValue dev_id:14 val:26038.000000 sc:0
[2026-08-01 17:58:03.439 UTC] [V] OCMgr SetMeterValue PhId:0302, branchNo:01, valueId:713102, value:26038.000000, scaleFactor:0, devId:14
[2026-08-01 17:58:03.448 UTC] [V] 485DevCtl <C3:02> device_type:Battery
[2026-08-01 17:58:03.455 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:03.455 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:58:03.467 UTC] [V] 485ChCtl <C3> set rt:0
[2026-08-01 17:58:03.478 UTC] [V] 485ChCtl <C3> StartDeviceCommunicationForOutputFluctuationSuppressionControlBroadcast 4 cnt:179577, monitor_cnt:56, bc_elapsed:179577, min:10, max:40
[2026-08-01 17:58:03.479 UTC] [V] 485DevCtl <C3:03> Dev not PCS IsNeedToChangeOControlState
[2026-08-01 17:58:03.479 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :5
[2026-08-01 17:58:03.480 UTC] [V] 485ChCtl <C3> send request:Sungrow11
[2026-08-01 17:58:03.481 UTC] [D] 485AcReq <C3:03> PutOStream [5][0c00000100000006010469780001]
[2026-08-01 17:58:03.555 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:03.555 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:58:03.555 UTC] [V] OFSCtrl Control charge discharge proc start.
[2026-08-01 17:58:03.555 UTC] [V] OFSCtrl CHG 20 p_th(t):21165.150000 = p_th_old_:21194.850000 + lev_cd_:-0.300000 * (total_pcs_capacity_:297000.000000 * cof_spec_:2.000000 / 60 * (time_threshold_renew:10.000000 * 10)), min:-2062.500000, max:407900.000000
[2026-08-01 17:58:03.556 UTC] [V] OFSCtrl CHG 21 batt_w:21589.141079 = old:21635.621579 +  kp:0.550000 * e:-97.350000 + ki:0.000000 * sume:-12576.299857 + kd:0.040000 * (e:-97.350000 - e1:-273.900000)
[2026-08-01 17:58:03.556 UTC] [V] OFSCtrl CHG 21 battery threshold min:20000.000000 <= bat:21589.141079 <= max:196000.000000, adjust charge:0.000000, discharge:1000.000000
[2026-08-01 17:58:03.558 UTC] [V] OFSCtrl CHG 29 q:53.000000, mod(round):4.000000
[2026-08-01 17:58:03.558 UTC] [V] OFSCtrl discharge bat_w[0303]:6400.000000 += adjust:1000.000000
[2026-08-01 17:58:03.559 UTC] [D] OFSCtrl battery ctrl val:10.800000
[2026-08-01 17:58:03.565 UTC] [V] 485ChCtl <C3> battery limit on [54.000000,54.000000,64.000000,54.000000,] request.
[2026-08-01 17:58:03.569 UTC] [V] OFSCtrl Control charge discharge proc:01->02->BATT_CHK->03->04->05->06->10->12->13->15->16->18->19->20->21->22->23->24->25->27->23->24->25->27->23->24->25->27->23->24->25->27->28->29->30->31->32->30->31->32->30->31->32->30->31->32->33->34
[2026-08-01 17:58:03.603 UTC] [V] 485DevCtl <C3:03> AnalyzeResponseData proc restart cnt:17963 UPRstat:0
[2026-08-01 17:58:03.605 UTC] [D] 485DevCtl <C3:03> RcvDat status[0] len[11] [0001000000050104020119]
[2026-08-01 17:58:03.605 UTC] [D] 485DevCtl <C3:03> ResCnd OperationId [5] IsNormal[1]  ConditionType [lggrdev:Normal] Action[-1]
[2026-08-01 17:58:03.605 UTC] [V] 485DevCtl <C3:03> [01][121005][281.000000][1][℃]
[2026-08-01 17:58:03.606 UTC] [V] SummDat SetVrmValue dev_id:15 val:28100.000000 sc:3
[2026-08-01 17:58:03.606 UTC] [V] OCMgr SetMeterValue PhId:0303, branchNo:01, valueId:121005, value:281.000000, scaleFactor:1, devId:15
[2026-08-01 17:58:03.606 UTC] [V] 485DevCtl <C3:03> device_type:Battery
[2026-08-01 17:58:03.632 UTC] [V] 485ChCtl <C3> set rt:0
[2026-08-01 17:58:03.655 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:03.655 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:58:03.679 UTC] [V] 485ChCtl <C3> battery send request.1
[2026-08-01 17:58:03.680 UTC] [D] VarInf Limit_Bat rt[2]set val[54] set rate[10.800000] value100[500] value-100[-500]
[2026-08-01 17:58:03.681 UTC] [D] VarInf Limit_Bat rt[2]set val[54] set rate[10.800000] value100[500] value-100[-500]
[2026-08-01 17:58:03.682 UTC] [D] VarInf Limit_Bat rt[2]set val[64] set rate[12.800000] value100[500] value-100[-500]
[2026-08-01 17:58:03.691 UTC] [D] VarInf Limit_Bat rt[2]set val[54] set rate[10.800000] value100[500] value-100[-500]
[2026-08-01 17:58:03.694 UTC] [D] 485AcReq <C3:01> PutOStream [6][0f000001000000090110278e0001020036]
[2026-08-01 17:58:03.695 UTC] [D] 485AcReq <C3:02> PutOStream [6][0f000001000000090110278e0001020036]
[2026-08-01 17:58:03.696 UTC] [D] 485AcReq <C3:03> PutOStream [6][0f000001000000090110278e0001020040]
[2026-08-01 17:58:03.696 UTC] [D] 485AcReq <C3:04> PutOStream [6][0f000001000000090110278e0001020036]
[2026-08-01 17:58:03.755 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:03.755 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:58:03.855 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:03.855 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:58:03.884 UTC] [V] 485DevCtl <C3:01> AnalyzeResponseData proc restart cnt:17963 UPRstat:0
[2026-08-01 17:58:03.886 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:58:03.886 UTC] [D] 485DevCtl <C3:01> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:58:03.886 UTC] [D] 485DevCtl <C3:01> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:58:03.887 UTC] [V] 485DevCtl <C3:01> device_type:Battery
[2026-08-01 17:58:03.887 UTC] [V] 485DevCtl <C3:02> AnalyzeResponseData proc restart cnt:17963 UPRstat:0
[2026-08-01 17:58:03.888 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:58:03.889 UTC] [D] 485DevCtl <C3:02> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:58:03.889 UTC] [D] 485DevCtl <C3:02> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:58:03.889 UTC] [V] 485DevCtl <C3:02> device_type:Battery
[2026-08-01 17:58:03.889 UTC] [V] 485DevCtl <C3:03> AnalyzeResponseData proc restart cnt:17963 UPRstat:0
[2026-08-01 17:58:03.930 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:58:03.941 UTC] [D] 485DevCtl <C3:03> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:58:03.941 UTC] [D] 485DevCtl <C3:03> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:58:03.941 UTC] [V] 485DevCtl <C3:03> device_type:Battery
[2026-08-01 17:58:03.942 UTC] [V] 485DevCtl <C3:04> AnalyzeResponseData proc restart cnt:17963 UPRstat:0
[2026-08-01 17:58:03.955 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:03.955 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:58:03.968 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:58:03.968 UTC] [D] 485DevCtl <C3:04> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:58:03.968 UTC] [D] 485DevCtl <C3:04> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:58:03.968 UTC] [V] 485DevCtl <C3:04> device_type:Battery
[2026-08-01 17:58:03.969 UTC] [V] 485ChCtl <C3> set rt:0
[2026-08-01 17:58:04.012 UTC] [V] OFSCtrl [/var/local/solajithome/function/output_fluctuation_suppression/batt_data] write success.
[2026-08-01 17:58:04.055 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:04.056 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:58:04.079 UTC] [V] 485ChCtl <C3> StartDeviceCommunicationForOutputFluctuationSuppressionControlBroadcast 4 cnt:179583, monitor_cnt:62, bc_elapsed:179583, min:10, max:40
[2026-08-01 17:58:04.079 UTC] [V] 485DevCtl <C3:04> Dev not PCS IsNeedToChangeOControlState
[2026-08-01 17:58:04.079 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :12
[2026-08-01 17:58:04.080 UTC] [V] 485ChCtl <C3> send request:Sungrow11
[2026-08-01 17:58:04.081 UTC] [D] 485AcReq <C3:04> PutOStream [12][0c00000100000006010427580001]
[2026-08-01 17:58:04.155 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:04.155 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:58:04.213 UTC] [V] 485DevCtl <C3:04> AnalyzeResponseData proc restart cnt:17963 UPRstat:0
[2026-08-01 17:58:04.215 UTC] [D] 485DevCtl <C3:04> RcvDat status[0] len[11] [0001000000050104020010]
[2026-08-01 17:58:04.215 UTC] [D] 485DevCtl <C3:04> ResCnd OperationId [12] IsNormal[1]  ConditionType [lggrdev:Normal] Action[-1]
[2026-08-01 17:58:04.216 UTC] [V] 485DevCtl <C3:04> [02][753040][1.000000][0][]
[2026-08-01 17:58:04.216 UTC] [V] SummDat SetVrmValue dev_id:16 val:1.000000 sc:0
[2026-08-01 17:58:04.216 UTC] [V] OCMgr SetMeterValue PhId:0304, branchNo:02, valueId:753040, value:1.000000, scaleFactor:0, devId:16
[2026-08-01 17:58:04.216 UTC] [V] 485DevCtl <C3:04> device_type:Battery
[2026-08-01 17:58:04.217 UTC] [V] 485ChCtl <C3> set rt:0
[2026-08-01 17:58:04.231 UTC] [D] 485ChCtl <C3> monitoring dev All Send
[2026-08-01 17:58:04.255 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:04.255 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:58:04.355 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:04.355 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:58:04.455 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:04.455 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:58:04.555 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:04.555 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:58:04.555 UTC] [V] OFSCtrl Control charge discharge proc start.
[2026-08-01 17:58:04.555 UTC] [V] OFSCtrl CHG 20 p_th(t):21135.450000 = p_th_old_:21165.150000 + lev_cd_:-0.300000 * (total_pcs_capacity_:297000.000000 * cof_spec_:2.000000 / 60 * (time_threshold_renew:10.000000 * 10)), min:-2062.500000, max:407900.000000
[2026-08-01 17:58:04.556 UTC] [V] OFSCtrl CHG 21 batt_w:21518.075579 = old:21589.141079 +  kp:0.550000 * e:-127.050000 + ki:0.000000 * sume:-12703.349857 + kd:0.040000 * (e:-127.050000 - e1:-97.350000)
[2026-08-01 17:58:04.556 UTC] [V] OFSCtrl CHG 21 battery threshold min:20000.000000 <= bat:21518.075579 <= max:196000.000000, adjust charge:0.000000, discharge:1000.000000
[2026-08-01 17:58:04.556 UTC] [V] OFSCtrl CHG 29 q:53.000000, mod(round):3.000000
[2026-08-01 17:58:04.557 UTC] [V] OFSCtrl discharge bat_w[0303]:6400.000000 += adjust:1000.000000
[2026-08-01 17:58:04.558 UTC] [D] OFSCtrl battery ctrl val:10.800000
[2026-08-01 17:58:04.558 UTC] [V] 485ChCtl <C3> battery limit on [54.000000,54.000000,64.000000,53.000000,] request.
[2026-08-01 17:58:04.558 UTC] [V] OFSCtrl Control charge discharge proc:01->02->BATT_CHK->03->04->05->06->10->12->13->15->16->18->19->20->21->22->23->24->25->27->23->24->25->27->23->24->25->27->23->24->25->27->28->29->30->31->32->30->31->32->30->31->32->30->31->32->33->34
[2026-08-01 17:58:04.578 UTC] [V] 485ChCtl <C3> battery send request.1
[2026-08-01 17:58:04.579 UTC] [D] VarInf Limit_Bat rt[2]set val[54] set rate[10.800000] value100[500] value-100[-500]
[2026-08-01 17:58:04.581 UTC] [D] VarInf Limit_Bat rt[2]set val[54] set rate[10.800000] value100[500] value-100[-500]
[2026-08-01 17:58:04.582 UTC] [D] VarInf Limit_Bat rt[2]set val[64] set rate[12.800000] value100[500] value-100[-500]
[2026-08-01 17:58:04.587 UTC] [D] VarInf Limit_Bat rt[2]set val[53] set rate[10.600000] value100[500] value-100[-500]
[2026-08-01 17:58:04.606 UTC] [D] 485AcReq <C3:01> PutOStream [6][0f000001000000090110278e0001020036]
[2026-08-01 17:58:04.606 UTC] [D] 485AcReq <C3:02> PutOStream [6][0f000001000000090110278e0001020036]
[2026-08-01 17:58:04.607 UTC] [D] 485AcReq <C3:03> PutOStream [6][0f000001000000090110278e0001020040]
[2026-08-01 17:58:04.608 UTC] [D] 485AcReq <C3:04> PutOStream [6][0f000001000000090110278e0001020035]
[2026-08-01 17:58:04.655 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:04.655 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:58:04.755 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:04.755 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:58:04.784 UTC] [V] 485DevCtl <C3:01> AnalyzeResponseData proc restart cnt:17964 UPRstat:0
[2026-08-01 17:58:04.787 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:58:04.787 UTC] [D] 485DevCtl <C3:01> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:58:04.787 UTC] [D] 485DevCtl <C3:01> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:58:04.787 UTC] [V] 485DevCtl <C3:01> device_type:Battery
[2026-08-01 17:58:04.788 UTC] [V] 485DevCtl <C3:02> AnalyzeResponseData proc restart cnt:17964 UPRstat:0
[2026-08-01 17:58:04.789 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:58:04.790 UTC] [D] 485DevCtl <C3:02> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:58:04.790 UTC] [D] 485DevCtl <C3:02> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:58:04.790 UTC] [V] 485DevCtl <C3:02> device_type:Battery
[2026-08-01 17:58:04.790 UTC] [V] 485DevCtl <C3:03> AnalyzeResponseData proc restart cnt:17964 UPRstat:0
[2026-08-01 17:58:04.791 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:58:04.837 UTC] [D] 485DevCtl <C3:03> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:58:04.838 UTC] [D] 485DevCtl <C3:03> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:58:04.841 UTC] [V] 485DevCtl <C3:03> device_type:Battery
[2026-08-01 17:58:04.855 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:04.855 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:58:04.857 UTC] [V] 485DevCtl <C3:04> AnalyzeResponseData proc restart cnt:17964 UPRstat:0
[2026-08-01 17:58:04.871 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:58:04.884 UTC] [D] 485DevCtl <C3:04> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:58:04.893 UTC] [D] 485DevCtl <C3:04> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:58:04.894 UTC] [V] 485DevCtl <C3:04> device_type:Battery
[2026-08-01 17:58:04.902 UTC] [V] 485ChCtl <C3> set rt:0
[2026-08-01 17:58:04.955 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:04.955 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:58:05.012 UTC] [V] OFSCtrl [/var/local/solajithome/function/output_fluctuation_suppression/batt_data] write success.
[2026-08-01 17:58:05.056 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:05.056 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:58:05.155 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:05.156 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:58:05.255 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:05.256 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:58:05.355 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:05.355 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:58:05.455 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:05.455 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:58:05.555 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:05.555 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:58:05.555 UTC] [V] OFSCtrl Control charge discharge proc start.
[2026-08-01 17:58:05.556 UTC] [V] OFSCtrl CHG 20 p_th(t):21105.750000 = p_th_old_:21135.450000 + lev_cd_:-0.300000 * (total_pcs_capacity_:297000.000000 * cof_spec_:2.000000 / 60 * (time_threshold_renew:10.000000 * 10)), min:-2062.500000, max:407900.000000
[2026-08-01 17:58:05.556 UTC] [V] OFSCtrl CHG 21 batt_w:21430.675079 = old:21518.075579 +  kp:0.550000 * e:-156.750000 + ki:0.000000 * sume:-12860.099857 + kd:0.040000 * (e:-156.750000 - e1:-127.050000)
[2026-08-01 17:58:05.556 UTC] [V] OFSCtrl CHG 21 battery threshold min:20000.000000 <= bat:21430.675079 <= max:196000.000000, adjust charge:0.000000, discharge:1000.000000
[2026-08-01 17:58:05.556 UTC] [V] OFSCtrl CHG 29 q:53.000000, mod(round):2.000000
[2026-08-01 17:58:05.557 UTC] [V] OFSCtrl discharge bat_w[0303]:6400.000000 += adjust:1000.000000
[2026-08-01 17:58:05.557 UTC] [D] OFSCtrl battery ctrl val:10.700000
[2026-08-01 17:58:05.557 UTC] [V] 485ChCtl <C3> battery limit on [53.000000,54.000000,64.000000,53.000000,] request.
[2026-08-01 17:58:05.558 UTC] [V] OFSCtrl Control charge discharge proc:01->02->BATT_CHK->03->04->05->06->10->12->13->15->16->18->19->20->21->22->23->24->25->27->23->24->25->27->23->24->25->27->23->24->25->27->28->29->30->31->32->30->31->32->30->31->32->30->31->32->33->34
[2026-08-01 17:58:05.579 UTC] [V] 485ChCtl <C3> battery send request.1
[2026-08-01 17:58:05.579 UTC] [D] VarInf Limit_Bat rt[2]set val[53] set rate[10.600000] value100[500] value-100[-500]
[2026-08-01 17:58:05.580 UTC] [D] VarInf Limit_Bat rt[2]set val[54] set rate[10.800000] value100[500] value-100[-500]
[2026-08-01 17:58:05.581 UTC] [D] VarInf Limit_Bat rt[2]set val[64] set rate[12.800000] value100[500] value-100[-500]
[2026-08-01 17:58:05.597 UTC] [D] VarInf Limit_Bat rt[2]set val[53] set rate[10.600000] value100[500] value-100[-500]
[2026-08-01 17:58:05.603 UTC] [D] 485AcReq <C3:01> PutOStream [6][0f000001000000090110278e0001020035]
[2026-08-01 17:58:05.604 UTC] [D] 485AcReq <C3:02> PutOStream [6][0f000001000000090110278e0001020036]
[2026-08-01 17:58:05.606 UTC] [D] 485AcReq <C3:03> PutOStream [6][0f000001000000090110278e0001020040]
[2026-08-01 17:58:05.606 UTC] [D] 485AcReq <C3:04> PutOStream [6][0f000001000000090110278e0001020035]
[2026-08-01 17:58:05.655 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:05.656 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:58:05.755 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:05.755 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:58:05.756 UTC] [V] 485DevCtl <C1:01> device_type:Irr-Meter
[2026-08-01 17:58:05.756 UTC] [V] 485DevCtl <C1:01> device_type:Irr-Meter
[2026-08-01 17:58:05.756 UTC] [V] 485ChCtl <C1> fixed cycle Irr-Meter
[2026-08-01 17:58:05.756 UTC] [V] 485DevCtl <C1:01> Dev not PCS IsNeedToChangeOControlState
[2026-08-01 17:58:05.756 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :1
[2026-08-01 17:58:05.757 UTC] [V] 485ChCtl <C1> send request:Irr01
[2026-08-01 17:58:05.758 UTC] [D] 485AcReq <C1:01> PutOStream [1][080001040000000271cb]
[2026-08-01 17:58:05.784 UTC] [V] 485DevCtl <C3:01> AnalyzeResponseData proc restart cnt:17965 UPRstat:0
[2026-08-01 17:58:05.787 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:58:05.788 UTC] [D] 485DevCtl <C3:01> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:58:05.789 UTC] [D] 485DevCtl <C3:01> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:58:05.789 UTC] [V] 485DevCtl <C3:01> device_type:Battery
[2026-08-01 17:58:05.792 UTC] [V] 485DevCtl <C3:02> AnalyzeResponseData proc restart cnt:17965 UPRstat:0
[2026-08-01 17:58:05.812 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:58:05.818 UTC] [D] 485DevCtl <C3:02> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:58:05.819 UTC] [D] 485DevCtl <C3:02> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:58:05.821 UTC] [V] 485DevCtl <C3:02> device_type:Battery
[2026-08-01 17:58:05.826 UTC] [V] 485DevCtl <C3:03> AnalyzeResponseData proc restart cnt:17965 UPRstat:0
[2026-08-01 17:58:05.838 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:58:05.843 UTC] [D] 485DevCtl <C3:03> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:58:05.844 UTC] [D] 485DevCtl <C3:03> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:58:05.845 UTC] [V] 485DevCtl <C3:03> device_type:Battery
[2026-08-01 17:58:05.850 UTC] [V] 485DevCtl <C3:04> AnalyzeResponseData proc restart cnt:17965 UPRstat:0
[2026-08-01 17:58:05.855 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:05.855 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:58:05.871 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:58:05.871 UTC] [D] 485DevCtl <C3:04> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:58:05.871 UTC] [D] 485DevCtl <C3:04> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:58:05.871 UTC] [V] 485DevCtl <C3:04> device_type:Battery
[2026-08-01 17:58:05.876 UTC] [V] 485ChCtl <C3> set rt:0
[2026-08-01 17:58:05.955 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:05.955 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:58:06.012 UTC] [V] OFSCtrl [/var/local/solajithome/function/output_fluctuation_suppression/batt_data] write success.
[2026-08-01 17:58:06.055 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:06.055 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:58:06.092 UTC] [V] 485DevCtl <C1:01> AnalyzeResponseData proc restart cnt:17983 UPRstat:0
[2026-08-01 17:58:06.093 UTC] [V] Res no response condition. set normal condition.
[2026-08-01 17:58:06.093 UTC] [D] 485DevCtl <C1:01> RcvDat status[2] len[9] [010404000001fa7a57]
[2026-08-01 17:58:06.093 UTC] [D] 485DevCtl <C1:01> ResCnd OperationId [1] IsNormal[1] 
[2026-08-01 17:58:06.093 UTC] [V] OFSCtrl Rcv set flux_of_solar:0.000000
[2026-08-01 17:58:06.093 UTC] [V] 485DevCtl <C1:01> [01][401006][0.000000][1][W/m2]
[2026-08-01 17:58:06.094 UTC] [V] SummDat SetVrmValue dev_id:1 val:0.000000 sc:3
[2026-08-01 17:58:06.094 UTC] [V] OCMgr SetMeterValue PhId:0101, branchNo:01, valueId:401006, value:0.000000, scaleFactor:1, devId:1
[2026-08-01 17:58:06.095 UTC] [V] 485DevCtl <C1:01> [01][421005][256.000000][1][℃]
[2026-08-01 17:58:06.095 UTC] [V] SummDat SetVrmValue dev_id:1 val:25600.000000 sc:3
[2026-08-01 17:58:06.096 UTC] [V] OCMgr SetMeterValue PhId:0101, branchNo:01, valueId:421005, value:256.000000, scaleFactor:1, devId:1
[2026-08-01 17:58:06.096 UTC] [V] 485DevCtl <C1:01> device_type:Irr-Meter
[2026-08-01 17:58:06.096 UTC] [V] OFSCtrl Irr-Meter received.
[2026-08-01 17:58:06.097 UTC] [V] 485ChCtl <C1> set rt:0
[2026-08-01 17:58:06.098 UTC] [V] 485DevCtl <C1:01> device_type:Irr-Meter
[2026-08-01 17:58:06.155 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:06.155 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:58:06.156 UTC] [V] 485DevCtl <C1:04> device_type:CO-Meter
[2026-08-01 17:58:06.157 UTC] [V] 485DevCtl <C1:04> device_type:CO-Meter
[2026-08-01 17:58:06.157 UTC] [V] 485ChCtl <C1> fixed cycle CO-Meter
[2026-08-01 17:58:06.157 UTC] [V] 485DevCtl <C1:04> Dev not PCS IsNeedToChangeOControlState
[2026-08-01 17:58:06.157 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :1
[2026-08-01 17:58:06.158 UTC] [V] 485ChCtl <C1> send request:omron05
[2026-08-01 17:58:06.158 UTC] [D] 485AcReq <C1:04> PutOStream [1][0800040300030014b590]
[2026-08-01 17:58:06.255 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:06.255 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:58:06.355 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:06.355 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:58:06.455 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:06.455 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:58:06.555 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:06.555 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:58:06.555 UTC] [V] OFSCtrl Control charge discharge proc start.
[2026-08-01 17:58:06.556 UTC] [V] OFSCtrl CHG 20 p_th(t):21076.050000 = p_th_old_:21105.750000 + lev_cd_:-0.300000 * (total_pcs_capacity_:297000.000000 * cof_spec_:2.000000 / 60 * (time_threshold_renew:10.000000 * 10)), min:-2062.500000, max:407900.000000
[2026-08-01 17:58:06.556 UTC] [V] OFSCtrl CHG 21 batt_w:21326.939579 = old:21430.675079 +  kp:0.550000 * e:-186.450000 + ki:0.000000 * sume:-13046.549857 + kd:0.040000 * (e:-186.450000 - e1:-156.750000)
[2026-08-01 17:58:06.556 UTC] [V] OFSCtrl CHG 21 battery threshold min:20000.000000 <= bat:21326.939579 <= max:196000.000000, adjust charge:0.000000, discharge:1000.000000
[2026-08-01 17:58:06.558 UTC] [V] OFSCtrl CHG 29 q:53.000000, mod(round):1.000000
[2026-08-01 17:58:06.558 UTC] [V] OFSCtrl discharge bat_w[0303]:6400.000000 += adjust:1000.000000
[2026-08-01 17:58:06.558 UTC] [D] OFSCtrl battery ctrl val:10.700000
[2026-08-01 17:58:06.558 UTC] [V] 485ChCtl <C3> battery limit on [53.000000,53.000000,64.000000,53.000000,] request.
[2026-08-01 17:58:06.559 UTC] [V] OFSCtrl Control charge discharge proc:01->02->BATT_CHK->03->04->05->06->10->12->13->15->16->18->19->20->21->22->23->24->25->27->23->24->25->27->23->24->25->27->23->24->25->27->28->29->30->31->32->30->31->32->30->31->32->30->31->32->33->34
[2026-08-01 17:58:06.562 UTC] [V] 485DevCtl <C1:04> AnalyzeResponseData proc restart cnt:17983 UPRstat:0
[2026-08-01 17:58:06.563 UTC] [V] Res no response condition. set normal condition.
[2026-08-01 17:58:06.564 UTC] [D] 485DevCtl <C1:04> RcvDat status[2] len[45] [0403280000f54c0000fc760000e492000000640000025700034c8400000871ffffbeedffffff5a00233b03a7c5]
[2026-08-01 17:58:06.564 UTC] [D] 485DevCtl <C1:04> ResCnd OperationId [1] IsNormal[1] 
[2026-08-01 17:58:06.565 UTC] [V] OFSCtrl Rcv set p_co:21610.000000, p_co_old:21560.000000
[2026-08-01 17:58:06.565 UTC] [V] 485DevCtl <C1:04> [01][601260][2161.000000][2][kW]
[2026-08-01 17:58:06.565 UTC] [V] SummDat SetVrmValue dev_id:4 val:21610.000000 sc:3
[2026-08-01 17:58:06.565 UTC] [V] OCMgr SetMeterValue PhId:0104, branchNo:01, valueId:601260, value:2161.000000, scaleFactor:2, devId:4
[2026-08-01 17:58:06.566 UTC] [V] 485DevCtl <C1:04> [01][603260][2308867.000000][1][kWh]
[2026-08-01 17:58:06.566 UTC] [V] SummDat SetVrmValue dev_id:4 val:2308867.000000 sc:1
[2026-08-01 17:58:06.566 UTC] [V] OCMgr SetMeterValue PhId:0104, branchNo:01, valueId:603260, value:2308867.000000, scaleFactor:1, devId:4
[2026-08-01 17:58:06.566 UTC] [V] 485DevCtl <C1:04> device_type:CO-Meter
[2026-08-01 17:58:06.566 UTC] [V] OFSCtrl km50 received.
[2026-08-01 17:58:06.574 UTC] [V] OFSCtrl omron05_local_date :2026/08/02 ? 2026/08/02
[2026-08-01 17:58:06.576 UTC] [V] OFSCtrl omron05_local_time :2026/08/02 02 ? 2026/08/02 02
[2026-08-01 17:58:06.577 UTC] [V] OFSCtrl out of control time.
[2026-08-01 17:58:06.577 UTC] [V] OFSCtrl Control pv-pcs proc start.
[2026-08-01 17:58:06.577 UTC] [V] OFSCtrl NOD_month:-445.000000 = (NOD_month:13 - ((nod_max_/30):23.333333 * (cnt-1):12) * (30/cnt):1.666667 
[2026-08-01 17:58:06.578 UTC] [V] OFSCtrl PCS ratio_month:113.496241 = -k_inhibition_ratio_month:-0.097744 * NOD_month:-445.000000 + inhibition_ratio_max:70
[2026-08-01 17:58:06.578 UTC] [V] OFSCtrl PCS 05 inhibition_ratio:70.000000 = max(ratio_min:5, min(ratio:70, ratio_hour:70.000000, ratio_day:70.000000, ratio_month:113.496241))
[2026-08-01 17:58:06.578 UTC] [D] OFSCtrl pv-pcs ctrl val:0.000000 old:0.000000
[2026-08-01 17:58:06.578 UTC] [V] OCHisDB set rate:0 t_rate:0 cnt:34
[2026-08-01 17:58:06.578 UTC] [V] 485ChCtl <C3> battery send request.1
[2026-08-01 17:58:06.579 UTC] [D] VarInf Limit_Bat rt[2]set val[53] set rate[10.600000] value100[500] value-100[-500]
[2026-08-01 17:58:06.581 UTC] [D] VarInf Limit_Bat rt[2]set val[53] set rate[10.600000] value100[500] value-100[-500]
[2026-08-01 17:58:06.582 UTC] [D] VarInf Limit_Bat rt[2]set val[64] set rate[12.800000] value100[500] value-100[-500]
[2026-08-01 17:58:06.583 UTC] [D] VarInf Limit_Bat rt[2]set val[53] set rate[10.600000] value100[500] value-100[-500]
[2026-08-01 17:58:06.594 UTC] [D] 485AcReq <C3:01> PutOStream [6][0f000001000000090110278e0001020035]
[2026-08-01 17:58:06.595 UTC] [D] 485AcReq <C3:02> PutOStream [6][0f000001000000090110278e0001020035]
[2026-08-01 17:58:06.596 UTC] [D] 485AcReq <C3:03> PutOStream [6][0f000001000000090110278e0001020040]
[2026-08-01 17:58:06.596 UTC] [D] 485AcReq <C3:04> PutOStream [6][0f000001000000090110278e0001020035]
[2026-08-01 17:58:06.599 UTC] [V] 485ChCtl <C2> pv-pcs limit on [0.000000] request.
[2026-08-01 17:58:06.601 UTC] [V] OFSCtrl Control pv-pcs proc:BATT_CHK->01->02->03->04->05->06->07->09->09->10->11->12
[2026-08-01 17:58:06.601 UTC] [V] OFSCtrl Nod calc proc start.
[2026-08-01 17:58:06.605 UTC] [V] OFSCtrl ProcNodCountCalculation culc nod skip stop:0, pause:0, ctl_time:0
[2026-08-01 17:58:06.606 UTC] [V] OFSCtrl update p_co_old:21610.000000
[2026-08-01 17:58:06.607 UTC] [V] OFSCtrl Nod calc proc:
[2026-08-01 17:58:06.620 UTC] [V] 485ChCtl <C1> set rt:0
[2026-08-01 17:58:06.623 UTC] [V] 485DevCtl <C1:04> device_type:CO-Meter
[2026-08-01 17:58:06.655 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:06.655 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:58:06.664 UTC] [V] 485ChCtl <C2> pv-pcs send request.
[2026-08-01 17:58:06.664 UTC] [D] VarInf update ofs_rate:0.000000
[2026-08-01 17:58:06.664 UTC] [V] VarInf LimitSet rt[2] val[170] key[ValueOn]
[2026-08-01 17:58:06.665 UTC] [D] VarInf output_mode:8
[2026-08-01 17:58:06.665 UTC] [D] VarInf update ofs_rate:0.000000
[2026-08-01 17:58:06.665 UTC] [D] VarInf Limit setRate[0.000000] rate[0.000000] value100[1000.000000] value0[0.000000]
[2026-08-01 17:58:06.665 UTC] [V] 485DevCtl <C2:01> ChangeOutputRateToDevice rate:0.000000 set_rate1
[2026-08-01 17:58:06.665 UTC] [D] VarInf Limit rt[2] int_set_rate[1] server_rate[0.000000] rated_output[100.000000] solar_battery_power[100.000000]
[2026-08-01 17:58:06.666 UTC] [D] 485AcReq <C2:01> PutOStreamForBc [3][0d000010138e00020400aa0001466f]
[2026-08-01 17:58:06.755 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:06.755 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:58:06.774 UTC] [V] 485DevCtl <C3:01> AnalyzeResponseData proc restart cnt:17966 UPRstat:0
[2026-08-01 17:58:06.776 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:58:06.776 UTC] [D] 485DevCtl <C3:01> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:58:06.777 UTC] [D] 485DevCtl <C3:01> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:58:06.777 UTC] [V] 485DevCtl <C3:01> device_type:Battery
[2026-08-01 17:58:06.777 UTC] [V] 485DevCtl <C3:02> AnalyzeResponseData proc restart cnt:17966 UPRstat:0
[2026-08-01 17:58:06.792 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:58:06.803 UTC] [D] 485DevCtl <C3:02> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:58:06.803 UTC] [D] 485DevCtl <C3:02> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:58:06.803 UTC] [V] 485DevCtl <C3:02> device_type:Battery
[2026-08-01 17:58:06.804 UTC] [V] 485DevCtl <C3:03> AnalyzeResponseData proc restart cnt:17966 UPRstat:0
[2026-08-01 17:58:06.821 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:58:06.821 UTC] [D] 485DevCtl <C3:03> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:58:06.821 UTC] [D] 485DevCtl <C3:03> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:58:06.821 UTC] [V] 485DevCtl <C3:03> device_type:Battery
[2026-08-01 17:58:06.842 UTC] [V] 485DevCtl <C3:04> AnalyzeResponseData proc restart cnt:17966 UPRstat:0
[2026-08-01 17:58:06.855 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:06.855 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:58:06.860 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:58:06.879 UTC] [D] 485DevCtl <C3:04> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:58:06.884 UTC] [D] 485DevCtl <C3:04> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:58:06.894 UTC] [V] 485DevCtl <C3:04> device_type:Battery
[2026-08-01 17:58:06.894 UTC] [V] 485ChCtl <C3> set rt:0
[2026-08-01 17:58:06.955 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:06.955 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:58:06.957 UTC] [V] 485ChCtl <C2> set rt:0
[2026-08-01 17:58:07.012 UTC] [V] OFSCtrl [/var/local/solajithome/function/output_fluctuation_suppression/batt_data] write success.
[2026-08-01 17:58:07.055 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:07.055 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:58:07.155 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:07.156 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:58:07.255 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:07.255 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:58:07.355 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:07.355 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:58:07.364 UTC] [V] 485ChCtl <C2> StartDeviceCommunicationForOutputFluctuationSuppressionControlBroadcast 4 cnt:179616, monitor_cnt:50, bc_elapsed:179616, min:10, max:40
[2026-08-01 17:58:07.365 UTC] [V] OFSCtrl /var/local/solajithome/function/output_fluctuation_suppression/state is exist:0
[2026-08-01 17:58:07.365 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :4
[2026-08-01 17:58:07.365 UTC] [V] 485ChCtl <C2> send request:Sungrow08
[2026-08-01 17:58:07.366 UTC] [D] 485AcReq <C2:01> PutOStream [4][0800010413b400017568]
[2026-08-01 17:58:07.455 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:07.455 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:58:07.555 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:07.555 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:58:07.555 UTC] [V] OFSCtrl Control charge discharge proc start.
[2026-08-01 17:58:07.555 UTC] [V] OFSCtrl CHG 20 p_th(t):21046.350000 = p_th_old_:21076.050000 + lev_cd_:-0.300000 * (total_pcs_capacity_:297000.000000 * cof_spec_:2.000000 / 60 * (time_threshold_renew:10.000000 * 10)), min:-2062.500000, max:407900.000000
[2026-08-01 17:58:07.556 UTC] [V] OFSCtrl CHG 21 batt_w:21206.869079 = old:21326.939579 +  kp:0.550000 * e:-216.150000 + ki:0.000000 * sume:-13262.699857 + kd:0.040000 * (e:-216.150000 - e1:-186.450000)
[2026-08-01 17:58:07.557 UTC] [V] OFSCtrl CHG 21 battery threshold min:20000.000000 <= bat:21206.869079 <= max:196000.000000, adjust charge:0.000000, discharge:1000.000000
[2026-08-01 17:58:07.557 UTC] [V] OFSCtrl CHG 29 q:53.000000, mod(round):0.000000
[2026-08-01 17:58:07.558 UTC] [V] OFSCtrl discharge bat_w[0303]:6300.000000 += adjust:1000.000000
[2026-08-01 17:58:07.558 UTC] [D] OFSCtrl battery ctrl val:10.600000
[2026-08-01 17:58:07.558 UTC] [V] 485ChCtl <C3> battery limit on [53.000000,53.000000,63.000000,53.000000,] request.
[2026-08-01 17:58:07.558 UTC] [V] OFSCtrl Control charge discharge proc:01->02->BATT_CHK->03->04->05->06->10->12->13->15->16->18->19->20->21->22->23->24->25->27->23->24->25->27->23->24->25->27->23->24->25->27->28->29->30->31->32->30->31->32->30->31->32->30->31->32->33->34
[2026-08-01 17:58:07.579 UTC] [V] 485ChCtl <C3> battery send request.1
[2026-08-01 17:58:07.580 UTC] [D] VarInf Limit_Bat rt[2]set val[53] set rate[10.600000] value100[500] value-100[-500]
[2026-08-01 17:58:07.582 UTC] [D] VarInf Limit_Bat rt[2]set val[53] set rate[10.600000] value100[500] value-100[-500]
[2026-08-01 17:58:07.583 UTC] [D] VarInf Limit_Bat rt[2]set val[63] set rate[12.600000] value100[500] value-100[-500]
[2026-08-01 17:58:07.584 UTC] [D] VarInf Limit_Bat rt[2]set val[53] set rate[10.600000] value100[500] value-100[-500]
[2026-08-01 17:58:07.601 UTC] [D] 485AcReq <C3:01> PutOStream [6][0f000001000000090110278e0001020035]
[2026-08-01 17:58:07.603 UTC] [D] 485AcReq <C3:02> PutOStream [6][0f000001000000090110278e0001020035]
[2026-08-01 17:58:07.603 UTC] [D] 485AcReq <C3:03> PutOStream [6][0f000001000000090110278e000102003f]
[2026-08-01 17:58:07.604 UTC] [D] 485AcReq <C3:04> PutOStream [6][0f000001000000090110278e0001020035]
[2026-08-01 17:58:07.655 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:07.655 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:58:07.695 UTC] [D] 485DevCtl <C2:01> RcvDat status[2] len[7] [0104020000b930]
[2026-08-01 17:58:07.703 UTC] [D] 485DevCtl <C2:01> ResCnd OperationId [4] IsNormal[0]  ConditionType [lggrdev:Error] Action[-1]
[2026-08-01 17:58:07.712 UTC] [V] 485DevCtl <C2:01> device_type:PV-PCS
[2026-08-01 17:58:07.719 UTC] [V] 485ChCtl <C2> set rt:0
[2026-08-01 17:58:07.755 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:07.755 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:58:07.764 UTC] [V] 485ChCtl <C2> StartDeviceCommunicationForOutputFluctuationSuppressionControlBroadcast 4 cnt:179620, monitor_cnt:54, bc_elapsed:179620, min:10, max:40
[2026-08-01 17:58:07.765 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :4
[2026-08-01 17:58:07.765 UTC] [V] 485ChCtl <C2> send request:Sungrow08
[2026-08-01 17:58:07.766 UTC] [D] 485AcReq <C2:02> PutOStream [4][0800020413b40001755b]
[2026-08-01 17:58:07.794 UTC] [V] 485DevCtl <C3:01> AnalyzeResponseData proc restart cnt:17967 UPRstat:0
[2026-08-01 17:58:07.797 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:58:07.798 UTC] [D] 485DevCtl <C3:01> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:58:07.798 UTC] [D] 485DevCtl <C3:01> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:58:07.798 UTC] [V] 485DevCtl <C3:01> device_type:Battery
[2026-08-01 17:58:07.799 UTC] [V] 485DevCtl <C3:02> AnalyzeResponseData proc restart cnt:17967 UPRstat:0
[2026-08-01 17:58:07.800 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:58:07.828 UTC] [D] 485DevCtl <C3:02> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:58:07.829 UTC] [D] 485DevCtl <C3:02> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:58:07.831 UTC] [V] 485DevCtl <C3:02> device_type:Battery
[2026-08-01 17:58:07.832 UTC] [V] 485DevCtl <C3:03> AnalyzeResponseData proc restart cnt:17967 UPRstat:0
[2026-08-01 17:58:07.855 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:07.855 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:58:07.858 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:58:07.859 UTC] [D] 485DevCtl <C3:03> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:58:07.860 UTC] [D] 485DevCtl <C3:03> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:58:07.860 UTC] [V] 485DevCtl <C3:03> device_type:Battery
[2026-08-01 17:58:07.862 UTC] [V] 485DevCtl <C3:04> AnalyzeResponseData proc restart cnt:17967 UPRstat:0
[2026-08-01 17:58:07.885 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:58:07.885 UTC] [D] 485DevCtl <C3:04> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:58:07.885 UTC] [D] 485DevCtl <C3:04> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:58:07.893 UTC] [V] 485DevCtl <C3:04> device_type:Battery
[2026-08-01 17:58:07.902 UTC] [V] 485ChCtl <C3> set rt:0
[2026-08-01 17:58:07.955 UTC] [V] OFSCtrl limit chk 400 < 800 < [1194->1194] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:07.955 UTC] [V] OFSCtrl angif value:1194 power_val_:21262.500000
[2026-08-01 17:58:08.012 UTC] [V] OFSCtrl [/var/local/solajithome/function/output_fluctuation_suppression/batt_data] write success.
[2026-08-01 17:58:08.055 UTC] [V] OFSCtrl limit chk 400 < 800 < [1193->1193] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:08.055 UTC] [V] OFSCtrl angif value:1193 power_val_:21056.250000
[2026-08-01 17:58:08.101 UTC] [D] 485DevCtl <C2:02> RcvDat status[2] len[7] [0204020000fd30]
[2026-08-01 17:58:08.101 UTC] [D] 485DevCtl <C2:02> ResCnd OperationId [4] IsNormal[0]  ConditionType [lggrdev:Error] Action[-1]
[2026-08-01 17:58:08.107 UTC] [V] 485DevCtl <C2:02> device_type:PV-PCS
[2026-08-01 17:58:08.109 UTC] [V] 485ChCtl <C2> set rt:0
[2026-08-01 17:58:08.156 UTC] [V] OFSCtrl limit chk 400 < 800 < [1192->1192] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:08.156 UTC] [V] OFSCtrl angif value:1192 power_val_:20850.000000
[2026-08-01 17:58:08.164 UTC] [V] 485ChCtl <C2> StartDeviceCommunicationForOutputFluctuationSuppressionControlBroadcast 4 cnt:179624, monitor_cnt:58, bc_elapsed:179624, min:10, max:40
[2026-08-01 17:58:08.164 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :4
[2026-08-01 17:58:08.165 UTC] [V] 485ChCtl <C2> send request:Sungrow08
[2026-08-01 17:58:08.166 UTC] [D] 485AcReq <C2:03> PutOStream [4][0800030413b40001748a]
[2026-08-01 17:58:08.255 UTC] [V] OFSCtrl limit chk 400 < 800 < [1192->1192] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:08.256 UTC] [V] OFSCtrl angif value:1192 power_val_:20850.000000
[2026-08-01 17:58:08.355 UTC] [V] OFSCtrl limit chk 400 < 800 < [1193->1193] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:08.355 UTC] [V] OFSCtrl angif value:1193 power_val_:21056.250000
[2026-08-01 17:58:08.455 UTC] [V] OFSCtrl limit chk 400 < 800 < [1193->1193] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:08.455 UTC] [V] OFSCtrl angif value:1193 power_val_:21056.250000
[2026-08-01 17:58:08.493 UTC] [D] 485DevCtl <C2:03> RcvDat status[2] len[7] [0304020000c0f0]
[2026-08-01 17:58:08.493 UTC] [D] 485DevCtl <C2:03> ResCnd OperationId [4] IsNormal[0]  ConditionType [lggrdev:Error] Action[-1]
[2026-08-01 17:58:08.506 UTC] [V] 485DevCtl <C2:03> device_type:PV-PCS
[2026-08-01 17:58:08.518 UTC] [V] 485ChCtl <C2> set rt:0
[2026-08-01 17:58:08.555 UTC] [V] OFSCtrl limit chk 400 < 800 < [1193->1193] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:08.555 UTC] [V] OFSCtrl angif value:1193 power_val_:21056.250000
[2026-08-01 17:58:08.555 UTC] [V] OFSCtrl Control charge discharge proc start.
[2026-08-01 17:58:08.556 UTC] [V] OFSCtrl CHG 20 p_th(t):21016.650000 = p_th_old_:21046.350000 + lev_cd_:-0.300000 * (total_pcs_capacity_:297000.000000 * cof_spec_:2.000000 / 60 * (time_threshold_renew:10.000000 * 10)), min:-2062.500000, max:407900.000000
[2026-08-01 17:58:08.556 UTC] [V] OFSCtrl CHG 21 batt_w:21192.151079 = old:21206.869079 +  kp:0.550000 * e:-39.600000 + ki:0.000000 * sume:-13302.299857 + kd:0.040000 * (e:-39.600000 - e1:-216.150000)
[2026-08-01 17:58:08.556 UTC] [V] OFSCtrl CHG 21 battery threshold min:20000.000000 <= bat:21192.151079 <= max:196000.000000, adjust charge:0.000000, discharge:1000.000000
[2026-08-01 17:58:08.557 UTC] [V] OFSCtrl CHG 29 q:52.000000, mod(round):4.000000
[2026-08-01 17:58:08.557 UTC] [V] OFSCtrl discharge bat_w[0303]:6300.000000 += adjust:1000.000000
[2026-08-01 17:58:08.557 UTC] [D] OFSCtrl battery ctrl val:10.600000
[2026-08-01 17:58:08.557 UTC] [V] 485ChCtl <C3> battery limit on [53.000000,53.000000,63.000000,53.000000,] request.
[2026-08-01 17:58:08.557 UTC] [V] OFSCtrl Control charge discharge proc:01->02->BATT_CHK->03->04->05->06->10->12->13->15->16->18->19->20->21->22->23->24->25->27->23->24->25->27->23->24->25->27->23->24->25->27->28->29->30->31->32->30->31->32->30->31->32->30->31->32->33->34
[2026-08-01 17:58:08.564 UTC] [V] 485ChCtl <C2> StartDeviceCommunicationForOutputFluctuationSuppressionControlBroadcast 4 cnt:179628, monitor_cnt:62, bc_elapsed:179628, min:10, max:40
[2026-08-01 17:58:08.564 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :9
[2026-08-01 17:58:08.565 UTC] [V] 485ChCtl <C2> send request:Sungrow08
[2026-08-01 17:58:08.566 UTC] [D] 485AcReq <C2:04> PutOStream [9][0800040413fa001794e4]
[2026-08-01 17:58:08.578 UTC] [V] 485ChCtl <C3> battery send request.1
[2026-08-01 17:58:08.579 UTC] [D] VarInf Limit_Bat rt[2]set val[53] set rate[10.600000] value100[500] value-100[-500]
[2026-08-01 17:58:08.580 UTC] [D] VarInf Limit_Bat rt[2]set val[53] set rate[10.600000] value100[500] value-100[-500]
[2026-08-01 17:58:08.581 UTC] [D] VarInf Limit_Bat rt[2]set val[63] set rate[12.600000] value100[500] value-100[-500]
[2026-08-01 17:58:08.590 UTC] [D] VarInf Limit_Bat rt[2]set val[53] set rate[10.600000] value100[500] value-100[-500]
[2026-08-01 17:58:08.599 UTC] [D] 485AcReq <C3:01> PutOStream [6][0f000001000000090110278e0001020035]
[2026-08-01 17:58:08.599 UTC] [D] 485AcReq <C3:02> PutOStream [6][0f000001000000090110278e0001020035]
[2026-08-01 17:58:08.600 UTC] [D] 485AcReq <C3:03> PutOStream [6][0f000001000000090110278e000102003f]
[2026-08-01 17:58:08.601 UTC] [D] 485AcReq <C3:04> PutOStream [6][0f000001000000090110278e0001020035]
[2026-08-01 17:58:08.655 UTC] [V] OFSCtrl limit chk 400 < 800 < [1193->1193] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:08.655 UTC] [V] OFSCtrl angif value:1193 power_val_:21056.250000
[2026-08-01 17:58:08.755 UTC] [V] OFSCtrl limit chk 400 < 800 < [1193->1193] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:08.755 UTC] [V] OFSCtrl angif value:1193 power_val_:21056.250000
[2026-08-01 17:58:08.784 UTC] [V] 485DevCtl <C3:01> AnalyzeResponseData proc restart cnt:17968 UPRstat:0
[2026-08-01 17:58:08.786 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:58:08.786 UTC] [D] 485DevCtl <C3:01> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:58:08.786 UTC] [D] 485DevCtl <C3:01> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:58:08.787 UTC] [V] 485DevCtl <C3:01> device_type:Battery
[2026-08-01 17:58:08.789 UTC] [V] 485DevCtl <C3:02> AnalyzeResponseData proc restart cnt:17968 UPRstat:0
[2026-08-01 17:58:08.815 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:58:08.816 UTC] [D] 485DevCtl <C3:02> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:58:08.816 UTC] [D] 485DevCtl <C3:02> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:58:08.816 UTC] [V] 485DevCtl <C3:02> device_type:Battery
[2026-08-01 17:58:08.816 UTC] [V] 485DevCtl <C3:03> AnalyzeResponseData proc restart cnt:17968 UPRstat:0
[2026-08-01 17:58:08.818 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:58:08.818 UTC] [D] 485DevCtl <C3:03> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:58:08.818 UTC] [D] 485DevCtl <C3:03> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:58:08.818 UTC] [V] 485DevCtl <C3:03> device_type:Battery
[2026-08-01 17:58:08.819 UTC] [V] 485DevCtl <C3:04> AnalyzeResponseData proc restart cnt:17968 UPRstat:0
[2026-08-01 17:58:08.855 UTC] [V] OFSCtrl limit chk 400 < 800 < [1193->1193] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:08.855 UTC] [V] OFSCtrl angif value:1193 power_val_:21056.250000
[2026-08-01 17:58:08.856 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:58:08.857 UTC] [D] 485DevCtl <C3:04> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:58:08.857 UTC] [D] 485DevCtl <C3:04> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:58:08.864 UTC] [V] 485DevCtl <C3:04> device_type:Battery
[2026-08-01 17:58:08.868 UTC] [V] 485ChCtl <C3> set rt:0
[2026-08-01 17:58:08.947 UTC] [V] Res no response condition. set normal condition.
[2026-08-01 17:58:08.951 UTC] [D] 485DevCtl <C2:04> RcvDat status[2] len[51] [04042e000000000000000000000000ffffffffffffffff03e8ffffffff080d0000ffffffffffffffffffffffffffffffffad80]
[2026-08-01 17:58:08.951 UTC] [D] 485DevCtl <C2:04> ResCnd OperationId [9] IsNormal[1] 
[2026-08-01 17:58:08.955 UTC] [V] OFSCtrl limit chk 400 < 800 < [1193->1193] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:08.956 UTC] [V] OFSCtrl angif value:1193 power_val_:21056.250000
[2026-08-01 17:58:08.956 UTC] [V] 485DevCtl <C2:04> [04][101100][0.000000][1][V]
[2026-08-01 17:58:08.959 UTC] [V] SummDat SetVrmValue dev_id:10 val:0.000000 sc:3
[2026-08-01 17:58:08.970 UTC] [V] OCMgr SetMeterValue PhId:0204, branchNo:04, valueId:101100, value:0.000000, scaleFactor:1, devId:10
[2026-08-01 17:58:08.973 UTC] [V] 485DevCtl <C2:04> [04][101101][0.000000][1][A]
[2026-08-01 17:58:08.973 UTC] [V] SummDat SetVrmValue dev_id:10 val:0.000000 sc:3
[2026-08-01 17:58:08.977 UTC] [V] OCMgr SetMeterValue PhId:0204, branchNo:04, valueId:101101, value:0.000000, scaleFactor:1, devId:10
[2026-08-01 17:58:08.985 UTC] [V] 485DevCtl <C2:04> [05][101100][0.000000][1][V]
[2026-08-01 17:58:08.989 UTC] [V] SummDat SetVrmValue dev_id:10 val:0.000000 sc:3
[2026-08-01 17:58:08.989 UTC] [V] OCMgr SetMeterValue PhId:0204, branchNo:05, valueId:101100, value:0.000000, scaleFactor:1, devId:10
[2026-08-01 17:58:08.989 UTC] [V] 485DevCtl <C2:04> [05][101101][0.000000][1][A]
[2026-08-01 17:58:08.990 UTC] [V] SummDat SetVrmValue dev_id:10 val:0.000000 sc:3
[2026-08-01 17:58:08.990 UTC] [V] OCMgr SetMeterValue PhId:0204, branchNo:05, valueId:101101, value:0.000000, scaleFactor:1, devId:10
[2026-08-01 17:58:09.012 UTC] [V] OFSCtrl [/var/local/solajithome/function/output_fluctuation_suppression/batt_data] write success.
[2026-08-01 17:58:09.013 UTC] [V] 485DevCtl <C2:04> [06][101100][0.000000][1][V]
[2026-08-01 17:58:09.016 UTC] [V] SummDat SetVrmValue dev_id:10 val:0.000000 sc:3
[2026-08-01 17:58:09.025 UTC] [V] OCMgr SetMeterValue PhId:0204, branchNo:06, valueId:101100, value:0.000000, scaleFactor:1, devId:10
[2026-08-01 17:58:09.030 UTC] [V] 485DevCtl <C2:04> [06][101101][0.000000][1][A]
[2026-08-01 17:58:09.032 UTC] [V] SummDat SetVrmValue dev_id:10 val:0.000000 sc:3
[2026-08-01 17:58:09.044 UTC] [V] OCMgr SetMeterValue PhId:0204, branchNo:06, valueId:101101, value:0.000000, scaleFactor:1, devId:10
[2026-08-01 17:58:09.053 UTC] [V] 485DevCtl <C2:04> device_type:PV-PCS
[2026-08-01 17:58:09.053 UTC] [V] 485ChCtl <C2> set rt:0
[2026-08-01 17:58:09.055 UTC] [V] OFSCtrl limit chk 400 < 800 < [1193->1193] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:09.055 UTC] [V] OFSCtrl angif value:1193 power_val_:21056.250000
[2026-08-01 17:58:09.056 UTC] [V] 485ChCtl <C1> StartDeviceCommunicationForOutputFluctuationSuppressionControlBroadcast 4 cnt:179633, monitor_cnt:100, bc_elapsed:33, min:10, max:40
[2026-08-01 17:58:09.056 UTC] [V] OFSCtrl /var/local/solajithome/function/output_fluctuation_suppression/state is exist:0
[2026-08-01 17:58:09.064 UTC] [V] 485ChCtl <C2> StartDeviceCommunicationForOutputFluctuationSuppressionControlBroadcast 4 cnt:179633, monitor_cnt:67, bc_elapsed:179633, min:10, max:40
[2026-08-01 17:58:09.065 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :2
[2026-08-01 17:58:09.065 UTC] [V] 485ChCtl <C2> send request:Sungrow08
[2026-08-01 17:58:09.067 UTC] [D] 485AcReq <C2:05> PutOStream [2][0800050413d80002f4f0]
[2026-08-01 17:58:09.079 UTC] [V] 485ChCtl <C3> StartDeviceCommunicationForOutputFluctuationSuppressionControlBroadcast 4 cnt:179633, monitor_cnt:50, bc_elapsed:179633, min:10, max:40
[2026-08-01 17:58:09.079 UTC] [V] OFSCtrl /var/local/solajithome/function/output_fluctuation_suppression/state is exist:0
[2026-08-01 17:58:09.079 UTC] [V] 485DevCtl <C3:01> Dev not PCS IsNeedToChangeOControlState
[2026-08-01 17:58:09.080 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :12
[2026-08-01 17:58:09.081 UTC] [V] 485ChCtl <C3> send request:Sungrow11
[2026-08-01 17:58:09.082 UTC] [D] 485AcReq <C3:01> PutOStream [12][0c00000100000006010427580001]
[2026-08-01 17:58:09.155 UTC] [V] OFSCtrl limit chk 400 < 800 < [1193->1193] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:09.155 UTC] [V] OFSCtrl angif value:1193 power_val_:21056.250000
[2026-08-01 17:58:09.157 UTC] [V] 485ChCtl <C1> StartDeviceCommunicationForOutputFluctuationSuppressionControlBroadcast 4 cnt:179634, monitor_cnt:101, bc_elapsed:34, min:10, max:40
[2026-08-01 17:58:09.157 UTC] [V] 485DevCtl <C1:02> Dev not PCS IsNeedToChangeOControlState
[2026-08-01 17:58:09.157 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :1
[2026-08-01 17:58:09.158 UTC] [V] 485ChCtl <C1> send request:IMT01
[2026-08-01 17:58:09.158 UTC] [D] 485AcReq <C1:02> PutOStream [1][08000204000200019039]
[2026-08-01 17:58:09.213 UTC] [V] 485DevCtl <C3:01> AnalyzeResponseData proc restart cnt:17968 UPRstat:0
[2026-08-01 17:58:09.214 UTC] [D] 485DevCtl <C3:01> RcvDat status[0] len[11] [0001000000050104020010]
[2026-08-01 17:58:09.216 UTC] [D] 485DevCtl <C3:01> ResCnd OperationId [12] IsNormal[1]  ConditionType [lggrdev:Normal] Action[-1]
[2026-08-01 17:58:09.216 UTC] [V] 485DevCtl <C3:01> [02][753040][1.000000][0][]
[2026-08-01 17:58:09.216 UTC] [V] SummDat SetVrmValue dev_id:13 val:1.000000 sc:0
[2026-08-01 17:58:09.218 UTC] [V] OCMgr SetMeterValue PhId:0301, branchNo:02, valueId:753040, value:1.000000, scaleFactor:0, devId:13
[2026-08-01 17:58:09.219 UTC] [V] 485DevCtl <C3:01> device_type:Battery
[2026-08-01 17:58:09.225 UTC] [V] 485ChCtl <C3> set rt:0
[2026-08-01 17:58:09.255 UTC] [V] OFSCtrl limit chk 400 < 800 < [1193->1193] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:09.255 UTC] [V] OFSCtrl angif value:1193 power_val_:21056.250000
[2026-08-01 17:58:09.279 UTC] [V] 485ChCtl <C3> StartDeviceCommunicationForOutputFluctuationSuppressionControlBroadcast 4 cnt:179635, monitor_cnt:52, bc_elapsed:179635, min:10, max:40
[2026-08-01 17:58:09.279 UTC] [V] 485DevCtl <C3:02> Dev not PCS IsNeedToChangeOControlState
[2026-08-01 17:58:09.279 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :3
[2026-08-01 17:58:09.280 UTC] [V] 485ChCtl <C3> send request:Sungrow11
[2026-08-01 17:58:09.282 UTC] [D] 485AcReq <C3:02> PutOStream [3][0c00000100000006010435260018]
[2026-08-01 17:58:09.355 UTC] [V] OFSCtrl limit chk 400 < 800 < [1193->1193] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:09.355 UTC] [V] OFSCtrl angif value:1193 power_val_:21056.250000
[2026-08-01 17:58:09.403 UTC] [V] 485DevCtl <C3:02> AnalyzeResponseData proc restart cnt:17968 UPRstat:0
[2026-08-01 17:58:09.408 UTC] [D] 485DevCtl <C2:05> RcvDat status[2] len[9] [05040400100000bf81]
[2026-08-01 17:58:09.408 UTC] [D] 485DevCtl <C2:05> ResCnd OperationId [2] IsNormal[0]  ConditionType [lggrdev:Error] Action[4]
[2026-08-01 17:58:09.410 UTC] [V] 485DevCtl <C2:05> device_type:PV-PCS
[2026-08-01 17:58:09.410 UTC] [V] 485DevCtl <C2:05> ExecuteAction name:RestartCounter value0
[2026-08-01 17:58:09.410 UTC] [V] 485DevCtl <C2:05> ExecuteAction set start cnt:0
[2026-08-01 17:58:09.411 UTC] [V] 485ChCtl <C2> set rt:0
[2026-08-01 17:58:09.413 UTC] [D] 485DevCtl <C3:02> RcvDat status[0] len[57] [0001000000330104301ec0ffb601c203e81ec001c200010001ffff4000ffff013b013bffff008c008c00640064ffff7fee7fc6011d01090028]
[2026-08-01 17:58:09.413 UTC] [D] 485DevCtl <C3:02> ResCnd OperationId [3] IsNormal[1]  ConditionType [lggrdev:Normal] Action[-1]
[2026-08-01 17:58:09.413 UTC] [V] 485DevCtl <C3:02> [01][721100][7872.000000][1][V]
[2026-08-01 17:58:09.413 UTC] [V] SummDat SetVrmValue dev_id:14 val:787200.000000 sc:3
[2026-08-01 17:58:09.414 UTC] [V] OCMgr SetMeterValue PhId:0302, branchNo:01, valueId:721100, value:7872.000000, scaleFactor:1, devId:14
[2026-08-01 17:58:09.414 UTC] [V] 485DevCtl <C3:02> [01][721101][-74.000000][1][A]
[2026-08-01 17:58:09.425 UTC] [V] SummDat SetVrmValue dev_id:14 val:-7400.000000 sc:3
[2026-08-01 17:58:09.427 UTC] [V] OCMgr SetMeterValue PhId:0302, branchNo:01, valueId:721101, value:-74.000000, scaleFactor:1, devId:14
[2026-08-01 17:58:09.431 UTC] [V] OFSCtrl change set SOC(t):44.750000 drive cnt:4
[2026-08-01 17:58:09.435 UTC] [V] OFSCtrl Rcv set soc[0302]:45.000000
[2026-08-01 17:58:09.438 UTC] [V] 485DevCtl <C3:02> [01][721035][450.000000][1][%]
[2026-08-01 17:58:09.441 UTC] [V] SummDat SetVrmValue dev_id:14 val:45000.000000 sc:3
[2026-08-01 17:58:09.446 UTC] [V] OCMgr SetMeterValue PhId:0302, branchNo:01, valueId:721035, value:450.000000, scaleFactor:1, devId:14
[2026-08-01 17:58:09.446 UTC] [V] 485DevCtl <C3:02> [01][721036][1000.000000][1][%]
[2026-08-01 17:58:09.446 UTC] [V] SummDat SetVrmValue dev_id:14 val:100000.000000 sc:3
[2026-08-01 17:58:09.446 UTC] [V] OCMgr SetMeterValue PhId:0302, branchNo:01, valueId:721036, value:1000.000000, scaleFactor:1, devId:14
[2026-08-01 17:58:09.455 UTC] [V] OFSCtrl limit chk 400 < 800 < [1192->1192] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:09.456 UTC] [V] OFSCtrl angif value:1192 power_val_:20850.000000
[2026-08-01 17:58:09.460 UTC] [V] 485DevCtl <C3:02> [01][721030][32750.000000][4][V]
[2026-08-01 17:58:09.464 UTC] [V] 485ChCtl <C2> StartDeviceCommunicationForOutputFluctuationSuppressionControlBroadcast 4 cnt:179637, monitor_cnt:71, bc_elapsed:179637, min:10, max:40
[2026-08-01 17:58:09.464 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :4
[2026-08-01 17:58:09.465 UTC] [V] 485ChCtl <C2> send request:Sungrow08
[2026-08-01 17:58:09.466 UTC] [D] 485AcReq <C2:06> PutOStream [4][0800060413b4000174df]
[2026-08-01 17:58:09.463 UTC] [V] SummDat SetVrmValue dev_id:14 val:3275.000000 sc:3
[2026-08-01 17:58:09.469 UTC] [V] OCMgr SetMeterValue PhId:0302, branchNo:01, valueId:721030, value:32750.000000, scaleFactor:4, devId:14
[2026-08-01 17:58:09.475 UTC] [V] 485DevCtl <C3:02> [01][721031][32710.000000][4][V]
[2026-08-01 17:58:09.482 UTC] [V] SummDat SetVrmValue dev_id:14 val:3271.000000 sc:3
[2026-08-01 17:58:09.489 UTC] [V] 485DevCtl <C1:02> AnalyzeResponseData proc restart cnt:17986 UPRstat:0
[2026-08-01 17:58:09.489 UTC] [V] Res no response condition. set normal condition.
[2026-08-01 17:58:09.489 UTC] [D] 485DevCtl <C1:02> RcvDat status[2] len[7] [020402020fbc54]
[2026-08-01 17:58:09.489 UTC] [D] 485DevCtl <C1:02> ResCnd OperationId [1] IsNormal[1] 
[2026-08-01 17:58:09.490 UTC] [V] 485DevCtl <C1:02> [01][431005][277.000000][1][°C]
[2026-08-01 17:58:09.490 UTC] [V] SummDat SetVrmValue dev_id:2 val:27700.000000 sc:3
[2026-08-01 17:58:09.490 UTC] [V] OCMgr SetMeterValue PhId:0102, branchNo:01, valueId:431005, value:277.000000, scaleFactor:1, devId:2
[2026-08-01 17:58:09.490 UTC] [V] 485DevCtl <C1:02> device_type:
[2026-08-01 17:58:09.491 UTC] [V] 485ChCtl <C1> set rt:0
[2026-08-01 17:58:09.493 UTC] [V] OCMgr SetMeterValue PhId:0302, branchNo:01, valueId:721031, value:32710.000000, scaleFactor:4, devId:14
[2026-08-01 17:58:09.498 UTC] [V] 485DevCtl <C3:02> [01][721032][285.000000][1][℃]
[2026-08-01 17:58:09.498 UTC] [V] SummDat SetVrmValue dev_id:14 val:28500.000000 sc:3
[2026-08-01 17:58:09.499 UTC] [V] OCMgr SetMeterValue PhId:0302, branchNo:01, valueId:721032, value:285.000000, scaleFactor:1, devId:14
[2026-08-01 17:58:09.499 UTC] [V] 485DevCtl <C3:02> [01][721033][265.000000][1][℃]
[2026-08-01 17:58:09.499 UTC] [V] SummDat SetVrmValue dev_id:14 val:26500.000000 sc:3
[2026-08-01 17:58:09.499 UTC] [V] OCMgr SetMeterValue PhId:0302, branchNo:01, valueId:721033, value:265.000000, scaleFactor:1, devId:14
[2026-08-01 17:58:09.500 UTC] [V] 485DevCtl <C3:02> device_type:Battery
[2026-08-01 17:58:09.501 UTC] [V] 485ChCtl <C3> set rt:0
[2026-08-01 17:58:09.555 UTC] [V] OFSCtrl limit chk 400 < 800 < [1193->1193] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:09.555 UTC] [V] OFSCtrl angif value:1193 power_val_:21056.250000
[2026-08-01 17:58:09.556 UTC] [V] OFSCtrl Control charge discharge proc start.
[2026-08-01 17:58:09.556 UTC] [V] OFSCtrl CHG 20 p_th(t):20986.950000 = p_th_old_:21016.650000 + lev_cd_:-0.300000 * (total_pcs_capacity_:297000.000000 * cof_spec_:2.000000 / 60 * (time_threshold_renew:10.000000 * 10)), min:-2062.500000, max:407900.000000
[2026-08-01 17:58:09.556 UTC] [V] OFSCtrl CHG 21 batt_w:21152.848079 = old:21192.151079 +  kp:0.550000 * e:-69.300000 + ki:0.000000 * sume:-13371.599857 + kd:0.040000 * (e:-69.300000 - e1:-39.600000)
[2026-08-01 17:58:09.557 UTC] [V] 485ChCtl <C1> StartDeviceCommunicationForOutputFluctuationSuppressionControlBroadcast 4 cnt:179638, monitor_cnt:105, bc_elapsed:38, min:10, max:40
[2026-08-01 17:58:09.557 UTC] [V] 485DevCtl <C1:03> Dev not PCS IsNeedToChangeOControlState
[2026-08-01 17:58:09.557 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :1
[2026-08-01 17:58:09.558 UTC] [V] 485ChCtl <C1> send request:omron03
[2026-08-01 17:58:09.558 UTC] [D] 485AcReq <C1:03> PutOStream [1][08000303000000144427]
[2026-08-01 17:58:09.562 UTC] [V] OFSCtrl CHG 21 battery threshold min:20000.000000 <= bat:21152.848079 <= max:196000.000000, adjust charge:0.000000, discharge:1000.000000
[2026-08-01 17:58:09.563 UTC] [V] OFSCtrl CHG 29 q:52.000000, mod(round):4.000000
[2026-08-01 17:58:09.563 UTC] [V] OFSCtrl discharge bat_w[0303]:6300.000000 += adjust:1000.000000
[2026-08-01 17:58:09.564 UTC] [D] OFSCtrl battery ctrl val:10.600000
[2026-08-01 17:58:09.569 UTC] [V] 485ChCtl <C3> battery limit on [53.000000,53.000000,63.000000,53.000000,] request.
[2026-08-01 17:58:09.570 UTC] [V] OFSCtrl Control charge discharge proc:01->02->BATT_CHK->03->04->05->06->10->12->13->15->16->18->19->20->21->22->23->24->25->27->23->24->25->27->23->24->25->27->23->24->25->27->28->29->30->31->32->30->31->32->30->31->32->30->31->32->33->34
[2026-08-01 17:58:09.578 UTC] [V] 485ChCtl <C3> battery send request.1
[2026-08-01 17:58:09.579 UTC] [D] VarInf Limit_Bat rt[2]set val[53] set rate[10.600000] value100[500] value-100[-500]
[2026-08-01 17:58:09.580 UTC] [D] VarInf Limit_Bat rt[2]set val[53] set rate[10.600000] value100[500] value-100[-500]
[2026-08-01 17:58:09.581 UTC] [D] VarInf Limit_Bat rt[2]set val[63] set rate[12.600000] value100[500] value-100[-500]
[2026-08-01 17:58:09.581 UTC] [D] VarInf Limit_Bat rt[2]set val[53] set rate[10.600000] value100[500] value-100[-500]
[2026-08-01 17:58:09.592 UTC] [D] 485AcReq <C3:01> PutOStream [6][0f000001000000090110278e0001020035]
[2026-08-01 17:58:09.594 UTC] [D] 485AcReq <C3:02> PutOStream [6][0f000001000000090110278e0001020035]
[2026-08-01 17:58:09.595 UTC] [D] 485AcReq <C3:03> PutOStream [6][0f000001000000090110278e000102003f]
[2026-08-01 17:58:09.595 UTC] [D] 485AcReq <C3:04> PutOStream [6][0f000001000000090110278e0001020035]
[2026-08-01 17:58:09.655 UTC] [V] OFSCtrl limit chk 400 < 800 < [1193->1193] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:09.655 UTC] [V] OFSCtrl angif value:1193 power_val_:21056.250000
[2026-08-01 17:58:09.755 UTC] [V] OFSCtrl limit chk 400 < 800 < [1193->1193] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:09.755 UTC] [V] OFSCtrl angif value:1193 power_val_:21056.250000
[2026-08-01 17:58:09.764 UTC] [V] 485DevCtl <C3:01> AnalyzeResponseData proc restart cnt:17969 UPRstat:0
[2026-08-01 17:58:09.767 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:58:09.768 UTC] [D] 485DevCtl <C3:01> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:58:09.768 UTC] [D] 485DevCtl <C3:01> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:58:09.768 UTC] [V] 485DevCtl <C3:01> device_type:Battery
[2026-08-01 17:58:09.769 UTC] [V] 485DevCtl <C3:02> AnalyzeResponseData proc restart cnt:17969 UPRstat:0
[2026-08-01 17:58:09.789 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:58:09.800 UTC] [D] 485DevCtl <C2:06> RcvDat status[2] len[7] [06040200000cf0]
[2026-08-01 17:58:09.800 UTC] [D] 485DevCtl <C2:06> ResCnd OperationId [4] IsNormal[0]  ConditionType [lggrdev:Error] Action[-1]
[2026-08-01 17:58:09.800 UTC] [V] 485DevCtl <C2:06> device_type:PV-PCS
[2026-08-01 17:58:09.801 UTC] [V] 485ChCtl <C2> set rt:0
[2026-08-01 17:58:09.813 UTC] [D] 485DevCtl <C3:02> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:58:09.813 UTC] [D] 485DevCtl <C3:02> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:58:09.813 UTC] [V] 485DevCtl <C3:02> device_type:Battery
[2026-08-01 17:58:09.814 UTC] [V] 485DevCtl <C3:03> AnalyzeResponseData proc restart cnt:17969 UPRstat:0
[2026-08-01 17:58:09.820 UTC] [D] 485ChCtl <C2> monitoring dev All Send
[2026-08-01 17:58:09.839 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:58:09.839 UTC] [D] 485DevCtl <C3:03> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:58:09.839 UTC] [D] 485DevCtl <C3:03> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:58:09.839 UTC] [V] 485DevCtl <C3:03> device_type:Battery
[2026-08-01 17:58:09.840 UTC] [V] 485DevCtl <C3:04> AnalyzeResponseData proc restart cnt:17969 UPRstat:0
[2026-08-01 17:58:09.841 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:58:09.841 UTC] [D] 485DevCtl <C3:04> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:58:09.841 UTC] [D] 485DevCtl <C3:04> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:58:09.842 UTC] [V] 485DevCtl <C3:04> device_type:Battery
[2026-08-01 17:58:09.856 UTC] [V] OFSCtrl limit chk 400 < 800 < [1193->1193] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:09.856 UTC] [V] OFSCtrl angif value:1193 power_val_:21056.250000
[2026-08-01 17:58:09.870 UTC] [V] 485ChCtl <C3> set rt:0
[2026-08-01 17:58:09.879 UTC] [V] 485ChCtl <C3> StartDeviceCommunicationForOutputFluctuationSuppressionControlBroadcast 4 cnt:179641, monitor_cnt:58, bc_elapsed:179641, min:10, max:40
[2026-08-01 17:58:09.879 UTC] [V] 485DevCtl <C3:03> Dev not PCS IsNeedToChangeOControlState
[2026-08-01 17:58:09.879 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :12
[2026-08-01 17:58:09.880 UTC] [V] 485ChCtl <C3> send request:Sungrow11
[2026-08-01 17:58:09.881 UTC] [D] 485AcReq <C3:03> PutOStream [12][0c00000100000006010427580001]
[2026-08-01 17:58:09.953 UTC] [V] 485DevCtl <C1:03> AnalyzeResponseData proc restart cnt:17987 UPRstat:0
[2026-08-01 17:58:09.954 UTC] [V] Res no response condition. set normal condition.
[2026-08-01 17:58:09.955 UTC] [V] OFSCtrl limit chk 400 < 800 < [1193->1193] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:09.955 UTC] [V] OFSCtrl angif value:1193 power_val_:21056.250000
[2026-08-01 17:58:09.957 UTC] [D] 485DevCtl <C1:03> RcvDat status[2] len[45] [0303280000fc43000103a8000100620000061100000caf00000fa20000000300000258000024bd0000005e0073]
[2026-08-01 17:58:09.957 UTC] [D] 485DevCtl <C1:03> ResCnd OperationId [1] IsNormal[1] 
[2026-08-01 17:58:09.957 UTC] [V] 485DevCtl <C1:03> [01][301200][64579.000000][1][V]
[2026-08-01 17:58:09.958 UTC] [V] SummDat SetVrmValue dev_id:3 val:6457900.000000 sc:3
[2026-08-01 17:58:09.958 UTC] [V] OCMgr SetMeterValue PhId:0103, branchNo:01, valueId:301200, value:64579.000000, scaleFactor:1, devId:3
[2026-08-01 17:58:09.958 UTC] [V] 485DevCtl <C1:03> [01][301201][1553.000000][3][A]
[2026-08-01 17:58:09.958 UTC] [V] SummDat SetVrmValue dev_id:3 val:1553.000000 sc:3
[2026-08-01 17:58:09.958 UTC] [V] OCMgr SetMeterValue PhId:0103, branchNo:01, valueId:301201, value:1553.000000, scaleFactor:3, devId:3
[2026-08-01 17:58:09.968 UTC] [V] OFSCtrl Rcv set p_grid:940.000000
[2026-08-01 17:58:09.968 UTC] [V] 485DevCtl <C1:03> [01][601202][94.000000][2][kW]
[2026-08-01 17:58:09.968 UTC] [V] SummDat SetVrmValue dev_id:3 val:940.000000 sc:3
[2026-08-01 17:58:09.968 UTC] [V] OCMgr SetMeterValue PhId:0103, branchNo:01, valueId:601202, value:94.000000, scaleFactor:2, devId:3
[2026-08-01 17:58:09.975 UTC] [V] 485DevCtl <C1:03> device_type:Grid-Meter
[2026-08-01 17:58:09.984 UTC] [V] 485ChCtl <C1> set rt:0
[2026-08-01 17:58:10.003 UTC] [V] 485DevCtl <C3:03> AnalyzeResponseData proc restart cnt:17969 UPRstat:0
[2026-08-01 17:58:10.004 UTC] [D] 485DevCtl <C3:03> RcvDat status[0] len[11] [0001000000050104020010]
[2026-08-01 17:58:10.005 UTC] [D] 485DevCtl <C3:03> ResCnd OperationId [12] IsNormal[1]  ConditionType [lggrdev:Normal] Action[-1]
[2026-08-01 17:58:10.005 UTC] [V] 485DevCtl <C3:03> [02][753040][1.000000][0][]
[2026-08-01 17:58:10.006 UTC] [V] SummDat SetVrmValue dev_id:15 val:1.000000 sc:0
[2026-08-01 17:58:10.006 UTC] [V] OCMgr SetMeterValue PhId:0303, branchNo:02, valueId:753040, value:1.000000, scaleFactor:0, devId:15
[2026-08-01 17:58:10.006 UTC] [V] 485DevCtl <C3:03> device_type:Battery
[2026-08-01 17:58:10.007 UTC] [V] 485ChCtl <C3> set rt:0
[2026-08-01 17:58:10.012 UTC] [V] OFSCtrl [/var/local/solajithome/function/output_fluctuation_suppression/batt_data] write success.
[2026-08-01 17:58:10.055 UTC] [V] OFSCtrl limit chk 400 < 800 < [1193->1193] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:10.055 UTC] [V] OFSCtrl angif value:1193 power_val_:21056.250000
[2026-08-01 17:58:10.056 UTC] [V] 485ChCtl <C1> monitor no transmission period.
[2026-08-01 17:58:10.079 UTC] [V] 485ChCtl <C3> StartDeviceCommunicationForOutputFluctuationSuppressionControlBroadcast 4 cnt:179643, monitor_cnt:60, bc_elapsed:179643, min:10, max:40
[2026-08-01 17:58:10.079 UTC] [V] 485DevCtl <C3:04> Dev not PCS IsNeedToChangeOControlState
[2026-08-01 17:58:10.079 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :1
[2026-08-01 17:58:10.080 UTC] [V] 485ChCtl <C3> send request:Sungrow11
[2026-08-01 17:58:10.081 UTC] [D] 485AcReq <C3:04> PutOStream [1][0c00000100000006010327470048]
[2026-08-01 17:58:10.155 UTC] [V] OFSCtrl limit chk 400 < 800 < [1193->1193] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:10.155 UTC] [V] OFSCtrl angif value:1193 power_val_:21056.250000
[2026-08-01 17:58:10.157 UTC] [V] 485ChCtl <C1> monitor no transmission period.
[2026-08-01 17:58:10.223 UTC] [V] 485DevCtl <C3:04> AnalyzeResponseData proc restart cnt:17969 UPRstat:0
[2026-08-01 17:58:10.244 UTC] [D] 485DevCtl <C3:04> RcvDat status[0] len[153] [0001000000930103900001000200000000005500550000005500aa00a000fa000000fa0001000000000000000000000019ffffffffffffffffffffffffffffffffffffffffffff000100000000ffff0000ffffffffffffffffffffffffffffffffffff0fa0177003e800000e101388000a000a00000000195020d000000000000000550055fffb0032ffff0000000000000000000000000035]
[2026-08-01 17:58:10.246 UTC] [D] 485DevCtl <C3:04> ResCnd OperationId [1] IsNormal[1]  ConditionType [lggrdev:Normal] Action[-1]
[2026-08-01 17:58:10.255 UTC] [V] OFSCtrl limit chk 400 < 800 < [1193->1193] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:10.255 UTC] [V] OFSCtrl angif value:1193 power_val_:21056.250000
[2026-08-01 17:58:10.256 UTC] [V] 485ChCtl <C1> monitor no transmission period.
[2026-08-01 17:58:10.256 UTC] [V] 485DevCtl <C3:04> [01][753049][0.000000][0][]
[2026-08-01 17:58:10.260 UTC] [V] SummDat SetVrmValue dev_id:16 val:0.000000 sc:0
[2026-08-01 17:58:10.260 UTC] [V] OCMgr SetMeterValue PhId:0304, branchNo:01, valueId:753049, value:0.000000, scaleFactor:0, devId:16
[2026-08-01 17:58:10.261 UTC] [V] OFSCtrl Rcv set BATT(t-1)[0304]:0.106000 value:5300.000000/50000 BATT(t-1):0.111000 <- 22200.000000/200000
[2026-08-01 17:58:10.261 UTC] [V] 485DevCtl <C3:04> [01][753102][53.000000][1][kW]
[2026-08-01 17:58:10.261 UTC] [V] SummDat SetVrmValue dev_id:16 val:53.000000 sc:1
[2026-08-01 17:58:10.274 UTC] [V] OCMgr SetMeterValue PhId:0304, branchNo:01, valueId:753102, value:53.000000, scaleFactor:1, devId:16
[2026-08-01 17:58:10.282 UTC] [V] 485DevCtl <C3:04> device_type:Battery
[2026-08-01 17:58:10.299 UTC] [V] 485ChCtl <C3> set rt:0
[2026-08-01 17:58:10.299 UTC] [D] 485ChCtl <C3> monitoring dev All Send
[2026-08-01 17:58:10.355 UTC] [V] OFSCtrl limit chk 400 < 800 < [1192->1192] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:10.356 UTC] [V] OFSCtrl angif value:1192 power_val_:20850.000000
[2026-08-01 17:58:10.356 UTC] [V] 485ChCtl <C1> monitor no transmission period.
[2026-08-01 17:58:10.455 UTC] [V] OFSCtrl limit chk 400 < 800 < [1193->1193] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:10.455 UTC] [V] OFSCtrl angif value:1193 power_val_:21056.250000
[2026-08-01 17:58:10.456 UTC] [V] 485ChCtl <C1> monitor no transmission period.
[2026-08-01 17:58:10.555 UTC] [V] OFSCtrl limit chk 400 < 800 < [1193->1193] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:10.555 UTC] [V] OFSCtrl angif value:1193 power_val_:21056.250000
[2026-08-01 17:58:10.555 UTC] [V] OFSCtrl Control charge discharge proc start.
[2026-08-01 17:58:10.556 UTC] [V] OFSCtrl CHG 20 p_th(t):20957.250000 = p_th_old_:20986.950000 + lev_cd_:-0.300000 * (total_pcs_capacity_:297000.000000 * cof_spec_:2.000000 / 60 * (time_threshold_renew:10.000000 * 10)), min:-2062.500000, max:407900.000000
[2026-08-01 17:58:10.556 UTC] [V] OFSCtrl CHG 21 batt_w:21097.210079 = old:21152.848079 +  kp:0.550000 * e:-99.000000 + ki:0.000000 * sume:-13470.599857 + kd:0.040000 * (e:-99.000000 - e1:-69.300000)
[2026-08-01 17:58:10.556 UTC] [V] OFSCtrl CHG 21 battery threshold min:20000.000000 <= bat:21097.210079 <= max:196000.000000, adjust charge:0.000000, discharge:1000.000000
[2026-08-01 17:58:10.557 UTC] [V] 485ChCtl <C1> monitor no transmission period.
[2026-08-01 17:58:10.557 UTC] [V] OFSCtrl CHG 29 q:52.000000, mod(round):3.000000
[2026-08-01 17:58:10.558 UTC] [V] OFSCtrl discharge bat_w[0303]:6300.000000 += adjust:1000.000000
[2026-08-01 17:58:10.558 UTC] [D] OFSCtrl battery ctrl val:10.500000
[2026-08-01 17:58:10.563 UTC] [V] 485ChCtl <C3> battery limit on [53.000000,53.000000,63.000000,52.000000,] request.
[2026-08-01 17:58:10.564 UTC] [V] OFSCtrl Control charge discharge proc:01->02->BATT_CHK->03->04->05->06->10->12->13->15->16->18->19->20->21->22->23->24->25->27->23->24->25->27->23->24->25->27->23->24->25->27->28->29->30->31->32->30->31->32->30->31->32->30->31->32->33->34
[2026-08-01 17:58:10.579 UTC] [V] 485ChCtl <C3> battery send request.1
[2026-08-01 17:58:10.579 UTC] [D] VarInf Limit_Bat rt[2]set val[53] set rate[10.600000] value100[500] value-100[-500]
[2026-08-01 17:58:10.580 UTC] [D] VarInf Limit_Bat rt[2]set val[53] set rate[10.600000] value100[500] value-100[-500]
[2026-08-01 17:58:10.581 UTC] [D] VarInf Limit_Bat rt[2]set val[63] set rate[12.600000] value100[500] value-100[-500]
[2026-08-01 17:58:10.602 UTC] [D] VarInf Limit_Bat rt[2]set val[52] set rate[10.400000] value100[500] value-100[-500]
[2026-08-01 17:58:10.610 UTC] [D] 485AcReq <C3:01> PutOStream [6][0f000001000000090110278e0001020035]
[2026-08-01 17:58:10.611 UTC] [D] 485AcReq <C3:02> PutOStream [6][0f000001000000090110278e0001020035]
[2026-08-01 17:58:10.611 UTC] [D] 485AcReq <C3:03> PutOStream [6][0f000001000000090110278e000102003f]
[2026-08-01 17:58:10.612 UTC] [D] 485AcReq <C3:04> PutOStream [6][0f000001000000090110278e0001020034]
[2026-08-01 17:58:10.655 UTC] [V] OFSCtrl limit chk 400 < 800 < [1193->1193] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:10.655 UTC] [V] OFSCtrl angif value:1193 power_val_:21056.250000
[2026-08-01 17:58:10.656 UTC] [V] 485ChCtl <C1> monitor no transmission period.
[2026-08-01 17:58:10.755 UTC] [V] OFSCtrl limit chk 400 < 800 < [1193->1193] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:10.755 UTC] [V] OFSCtrl angif value:1193 power_val_:21056.250000
[2026-08-01 17:58:10.756 UTC] [V] 485DevCtl <C1:01> device_type:Irr-Meter
[2026-08-01 17:58:10.756 UTC] [V] 485DevCtl <C1:01> device_type:Irr-Meter
[2026-08-01 17:58:10.756 UTC] [V] 485ChCtl <C1> fixed cycle Irr-Meter
[2026-08-01 17:58:10.757 UTC] [V] 485DevCtl <C1:01> Dev not PCS IsNeedToChangeOControlState
[2026-08-01 17:58:10.757 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :1
[2026-08-01 17:58:10.757 UTC] [V] 485ChCtl <C1> send request:Irr01
[2026-08-01 17:58:10.758 UTC] [D] 485AcReq <C1:01> PutOStream [1][080001040000000271cb]
[2026-08-01 17:58:10.804 UTC] [V] 485DevCtl <C3:01> AnalyzeResponseData proc restart cnt:17970 UPRstat:0
[2026-08-01 17:58:10.806 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:58:10.807 UTC] [D] 485DevCtl <C3:01> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:58:10.807 UTC] [D] 485DevCtl <C3:01> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:58:10.808 UTC] [V] 485DevCtl <C3:01> device_type:Battery
[2026-08-01 17:58:10.814 UTC] [V] 485DevCtl <C3:02> AnalyzeResponseData proc restart cnt:17970 UPRstat:0
[2026-08-01 17:58:10.827 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:58:10.839 UTC] [D] 485DevCtl <C3:02> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:58:10.842 UTC] [D] 485DevCtl <C3:02> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:58:10.844 UTC] [V] 485DevCtl <C3:02> device_type:Battery
[2026-08-01 17:58:10.855 UTC] [V] OFSCtrl limit chk 400 < 800 < [1192->1192] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:10.855 UTC] [V] OFSCtrl angif value:1192 power_val_:20850.000000
[2026-08-01 17:58:10.854 UTC] [V] 485DevCtl <C3:03> AnalyzeResponseData proc restart cnt:17970 UPRstat:0
[2026-08-01 17:58:10.874 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:58:10.875 UTC] [D] 485DevCtl <C3:03> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:58:10.875 UTC] [D] 485DevCtl <C3:03> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:58:10.875 UTC] [V] 485DevCtl <C3:03> device_type:Battery
[2026-08-01 17:58:10.888 UTC] [V] 485DevCtl <C3:04> AnalyzeResponseData proc restart cnt:17970 UPRstat:0
[2026-08-01 17:58:10.893 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:58:10.893 UTC] [D] 485DevCtl <C3:04> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:58:10.893 UTC] [D] 485DevCtl <C3:04> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:58:10.893 UTC] [V] 485DevCtl <C3:04> device_type:Battery
[2026-08-01 17:58:10.894 UTC] [V] 485ChCtl <C3> set rt:0
[2026-08-01 17:58:10.955 UTC] [V] OFSCtrl limit chk 400 < 800 < [1191->1191] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:10.955 UTC] [V] OFSCtrl angif value:1191 power_val_:20643.750000
[2026-08-01 17:58:11.012 UTC] [V] OFSCtrl [/var/local/solajithome/function/output_fluctuation_suppression/batt_data] write success.
[2026-08-01 17:58:11.055 UTC] [V] OFSCtrl limit chk 400 < 800 < [1192->1192] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:11.055 UTC] [V] OFSCtrl angif value:1192 power_val_:20850.000000
[2026-08-01 17:58:11.089 UTC] [V] 485DevCtl <C1:01> AnalyzeResponseData proc restart cnt:17988 UPRstat:0
[2026-08-01 17:58:11.089 UTC] [V] Res no response condition. set normal condition.
[2026-08-01 17:58:11.089 UTC] [D] 485DevCtl <C1:01> RcvDat status[2] len[9] [010404000001fa7a57]
[2026-08-01 17:58:11.089 UTC] [D] 485DevCtl <C1:01> ResCnd OperationId [1] IsNormal[1] 
[2026-08-01 17:58:11.090 UTC] [V] OFSCtrl Rcv set flux_of_solar:0.000000
[2026-08-01 17:58:11.090 UTC] [V] 485DevCtl <C1:01> [01][401006][0.000000][1][W/m2]
[2026-08-01 17:58:11.090 UTC] [V] SummDat SetVrmValue dev_id:1 val:0.000000 sc:3
[2026-08-01 17:58:11.090 UTC] [V] OCMgr SetMeterValue PhId:0101, branchNo:01, valueId:401006, value:0.000000, scaleFactor:1, devId:1
[2026-08-01 17:58:11.091 UTC] [V] 485DevCtl <C1:01> [01][421005][256.000000][1][℃]
[2026-08-01 17:58:11.091 UTC] [V] SummDat SetVrmValue dev_id:1 val:25600.000000 sc:3
[2026-08-01 17:58:11.091 UTC] [V] OCMgr SetMeterValue PhId:0101, branchNo:01, valueId:421005, value:256.000000, scaleFactor:1, devId:1
[2026-08-01 17:58:11.091 UTC] [V] 485DevCtl <C1:01> device_type:Irr-Meter
[2026-08-01 17:58:11.091 UTC] [V] OFSCtrl Irr-Meter received.
[2026-08-01 17:58:11.097 UTC] [V] 485ChCtl <C1> set rt:0
[2026-08-01 17:58:11.098 UTC] [V] 485DevCtl <C1:01> device_type:Irr-Meter
[2026-08-01 17:58:11.155 UTC] [V] OFSCtrl limit chk 400 < 800 < [1192->1192] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:11.156 UTC] [V] OFSCtrl angif value:1192 power_val_:20850.000000
[2026-08-01 17:58:11.157 UTC] [V] 485DevCtl <C1:04> device_type:CO-Meter
[2026-08-01 17:58:11.157 UTC] [V] 485DevCtl <C1:04> device_type:CO-Meter
[2026-08-01 17:58:11.157 UTC] [V] 485ChCtl <C1> fixed cycle CO-Meter
[2026-08-01 17:58:11.157 UTC] [V] 485DevCtl <C1:04> Dev not PCS IsNeedToChangeOControlState
[2026-08-01 17:58:11.157 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :1
[2026-08-01 17:58:11.158 UTC] [V] 485ChCtl <C1> send request:omron05
[2026-08-01 17:58:11.159 UTC] [D] 485AcReq <C1:04> PutOStream [1][0800040300030014b590]
[2026-08-01 17:58:11.255 UTC] [V] OFSCtrl limit chk 400 < 800 < [1192->1192] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:11.255 UTC] [V] OFSCtrl angif value:1192 power_val_:20850.000000
[2026-08-01 17:58:11.355 UTC] [V] OFSCtrl limit chk 400 < 800 < [1192->1192] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:11.355 UTC] [V] OFSCtrl angif value:1192 power_val_:20850.000000
[2026-08-01 17:58:11.455 UTC] [V] OFSCtrl limit chk 400 < 800 < [1192->1192] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:11.455 UTC] [V] OFSCtrl angif value:1192 power_val_:20850.000000
[2026-08-01 17:58:11.555 UTC] [V] OFSCtrl limit chk 400 < 800 < [1192->1192] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:11.555 UTC] [V] OFSCtrl angif value:1192 power_val_:20850.000000
[2026-08-01 17:58:11.555 UTC] [V] OFSCtrl Control charge discharge proc start.
[2026-08-01 17:58:11.555 UTC] [V] OFSCtrl CHG 20 p_th(t):20927.550000 = p_th_old_:20957.250000 + lev_cd_:-0.300000 * (total_pcs_capacity_:297000.000000 * cof_spec_:2.000000 / 60 * (time_threshold_renew:10.000000 * 10)), min:-2062.500000, max:407900.000000
[2026-08-01 17:58:11.556 UTC] [V] OFSCtrl CHG 21 batt_w:21146.924579 = old:21097.210079 +  kp:0.550000 * e:77.550000 + ki:0.000000 * sume:-13393.049857 + kd:0.040000 * (e:77.550000 - e1:-99.000000)
[2026-08-01 17:58:11.556 UTC] [V] OFSCtrl CHG 21 battery threshold min:20000.000000 <= bat:21146.924579 <= max:196000.000000, adjust charge:0.000000, discharge:1000.000000
[2026-08-01 17:58:11.560 UTC] [V] 485DevCtl <C1:04> AnalyzeResponseData proc restart cnt:17988 UPRstat:0
[2026-08-01 17:58:11.560 UTC] [V] Res no response condition. set normal condition.
[2026-08-01 17:58:11.561 UTC] [D] 485DevCtl <C1:04> RcvDat status[2] len[45] [0403280000f4450000fb720000e39a0000006400000257000348c900000868ffffbeebffffff5a00233b039def]
[2026-08-01 17:58:11.562 UTC] [D] 485DevCtl <C1:04> ResCnd OperationId [1] IsNormal[1] 
[2026-08-01 17:58:11.563 UTC] [V] OFSCtrl CHG 29 q:52.000000, mod(round):3.000000
[2026-08-01 17:58:11.563 UTC] [V] OFSCtrl discharge bat_w[0303]:6300.000000 += adjust:1000.000000
[2026-08-01 17:58:11.563 UTC] [D] OFSCtrl battery ctrl val:10.600000
[2026-08-01 17:58:11.564 UTC] [V] 485ChCtl <C3> battery limit on [53.000000,53.000000,63.000000,52.000000,] request.
[2026-08-01 17:58:11.565 UTC] [V] OFSCtrl Rcv set p_co:21520.000000, p_co_old:21610.000000
[2026-08-01 17:58:11.565 UTC] [V] 485DevCtl <C1:04> [01][601260][2152.000000][2][kW]
[2026-08-01 17:58:11.565 UTC] [V] SummDat SetVrmValue dev_id:4 val:21520.000000 sc:3
[2026-08-01 17:58:11.565 UTC] [V] OCMgr SetMeterValue PhId:0104, branchNo:01, valueId:601260, value:2152.000000, scaleFactor:2, devId:4
[2026-08-01 17:58:11.565 UTC] [V] 485DevCtl <C1:04> [01][603260][2308867.000000][1][kWh]
[2026-08-01 17:58:11.566 UTC] [V] SummDat SetVrmValue dev_id:4 val:2308867.000000 sc:1
[2026-08-01 17:58:11.566 UTC] [V] OCMgr SetMeterValue PhId:0104, branchNo:01, valueId:603260, value:2308867.000000, scaleFactor:1, devId:4
[2026-08-01 17:58:11.568 UTC] [V] OFSCtrl Control charge discharge proc:01->02->BATT_CHK->03->04->05->06->10->12->13->15->16->18->19->20->21->22->23->24->25->27->23->24->25->27->23->24->25->27->23->24->25->27->28->29->30->31->32->30->31->32->30->31->32->30->31->32->33->34
[2026-08-01 17:58:11.574 UTC] [V] 485DevCtl <C1:04> device_type:CO-Meter
[2026-08-01 17:58:11.575 UTC] [V] OFSCtrl km50 received.
[2026-08-01 17:58:11.576 UTC] [V] OFSCtrl omron05_local_date :2026/08/02 ? 2026/08/02
[2026-08-01 17:58:11.576 UTC] [V] OFSCtrl omron05_local_time :2026/08/02 02 ? 2026/08/02 02
[2026-08-01 17:58:11.577 UTC] [V] OFSCtrl out of control time.
[2026-08-01 17:58:11.578 UTC] [V] 485ChCtl <C3> battery send request.1
[2026-08-01 17:58:11.579 UTC] [D] VarInf Limit_Bat rt[2]set val[53] set rate[10.600000] value100[500] value-100[-500]
[2026-08-01 17:58:11.580 UTC] [D] VarInf Limit_Bat rt[2]set val[53] set rate[10.600000] value100[500] value-100[-500]
[2026-08-01 17:58:11.581 UTC] [D] VarInf Limit_Bat rt[2]set val[63] set rate[12.600000] value100[500] value-100[-500]
[2026-08-01 17:58:11.582 UTC] [D] VarInf Limit_Bat rt[2]set val[52] set rate[10.400000] value100[500] value-100[-500]
[2026-08-01 17:58:11.578 UTC] [V] OFSCtrl Control pv-pcs proc start.
[2026-08-01 17:58:11.585 UTC] [V] OFSCtrl NOD_month:-445.000000 = (NOD_month:13 - ((nod_max_/30):23.333333 * (cnt-1):12) * (30/cnt):1.666667 
[2026-08-01 17:58:11.589 UTC] [V] OFSCtrl PCS ratio_month:113.496241 = -k_inhibition_ratio_month:-0.097744 * NOD_month:-445.000000 + inhibition_ratio_max:70
[2026-08-01 17:58:11.594 UTC] [V] OFSCtrl PCS 05 inhibition_ratio:70.000000 = max(ratio_min:5, min(ratio:70, ratio_hour:70.000000, ratio_day:70.000000, ratio_month:113.496241))
[2026-08-01 17:58:11.597 UTC] [D] 485AcReq <C3:01> PutOStream [6][0f000001000000090110278e0001020035]
[2026-08-01 17:58:11.597 UTC] [D] 485AcReq <C3:02> PutOStream [6][0f000001000000090110278e0001020035]
[2026-08-01 17:58:11.598 UTC] [D] 485AcReq <C3:03> PutOStream [6][0f000001000000090110278e000102003f]
[2026-08-01 17:58:11.599 UTC] [D] 485AcReq <C3:04> PutOStream [6][0f000001000000090110278e0001020034]
[2026-08-01 17:58:11.602 UTC] [D] OFSCtrl pv-pcs ctrl val:0.000000 old:0.000000
[2026-08-01 17:58:11.604 UTC] [V] OCHisDB set rate:0 t_rate:0 cnt:35
[2026-08-01 17:58:11.612 UTC] [V] 485ChCtl <C2> pv-pcs limit on [0.000000] request.
[2026-08-01 17:58:11.612 UTC] [V] OFSCtrl Control pv-pcs proc:BATT_CHK->01->02->03->04->05->06->07->09->09->10->11->12
[2026-08-01 17:58:11.613 UTC] [V] 485ChCtl <C1> set rt:0
[2026-08-01 17:58:11.613 UTC] [V] 485DevCtl <C1:04> device_type:CO-Meter
[2026-08-01 17:58:11.655 UTC] [V] OFSCtrl limit chk 400 < 800 < [1192->1192] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:11.656 UTC] [V] OFSCtrl angif value:1192 power_val_:20850.000000
[2026-08-01 17:58:11.656 UTC] [V] 485ChCtl <C1> monitor no transmission period.
[2026-08-01 17:58:11.664 UTC] [V] 485ChCtl <C2> pv-pcs send request.
[2026-08-01 17:58:11.664 UTC] [D] VarInf update ofs_rate:0.000000
[2026-08-01 17:58:11.665 UTC] [V] VarInf LimitSet rt[2] val[170] key[ValueOn]
[2026-08-01 17:58:11.665 UTC] [D] VarInf output_mode:8
[2026-08-01 17:58:11.665 UTC] [D] VarInf update ofs_rate:0.000000
[2026-08-01 17:58:11.665 UTC] [D] VarInf Limit setRate[0.000000] rate[0.000000] value100[1000.000000] value0[0.000000]
[2026-08-01 17:58:11.665 UTC] [V] 485DevCtl <C2:01> ChangeOutputRateToDevice rate:0.000000 set_rate1
[2026-08-01 17:58:11.665 UTC] [D] VarInf Limit rt[2] int_set_rate[1] server_rate[0.000000] rated_output[100.000000] solar_battery_power[100.000000]
[2026-08-01 17:58:11.666 UTC] [D] 485AcReq <C2:01> PutOStreamForBc [3][0d000010138e00020400aa0001466f]
[2026-08-01 17:58:11.755 UTC] [V] OFSCtrl limit chk 400 < 800 < [1192->1192] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:11.755 UTC] [V] OFSCtrl angif value:1192 power_val_:20850.000000
[2026-08-01 17:58:11.757 UTC] [V] 485ChCtl <C1> monitor no transmission period.
[2026-08-01 17:58:11.774 UTC] [V] 485DevCtl <C3:01> AnalyzeResponseData proc restart cnt:17971 UPRstat:0
[2026-08-01 17:58:11.776 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:58:11.777 UTC] [D] 485DevCtl <C3:01> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:58:11.777 UTC] [D] 485DevCtl <C3:01> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:58:11.777 UTC] [V] 485DevCtl <C3:01> device_type:Battery
[2026-08-01 17:58:11.781 UTC] [V] 485DevCtl <C3:02> AnalyzeResponseData proc restart cnt:17971 UPRstat:0
[2026-08-01 17:58:11.799 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:58:11.805 UTC] [D] 485DevCtl <C3:02> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:58:11.807 UTC] [D] 485DevCtl <C3:02> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:58:11.808 UTC] [V] 485DevCtl <C3:02> device_type:Battery
[2026-08-01 17:58:11.813 UTC] [V] 485DevCtl <C3:03> AnalyzeResponseData proc restart cnt:17971 UPRstat:0
[2026-08-01 17:58:11.816 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:58:11.817 UTC] [D] 485DevCtl <C3:03> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:58:11.817 UTC] [D] 485DevCtl <C3:03> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:58:11.817 UTC] [V] 485DevCtl <C3:03> device_type:Battery
[2026-08-01 17:58:11.817 UTC] [V] 485DevCtl <C3:04> AnalyzeResponseData proc restart cnt:17971 UPRstat:0
[2026-08-01 17:58:11.839 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:58:11.844 UTC] [D] 485DevCtl <C3:04> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:58:11.845 UTC] [D] 485DevCtl <C3:04> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:58:11.847 UTC] [V] 485DevCtl <C3:04> device_type:Battery
[2026-08-01 17:58:11.851 UTC] [V] 485ChCtl <C3> set rt:0
[2026-08-01 17:58:11.855 UTC] [V] OFSCtrl limit chk 400 < 800 < [1192->1192] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:11.855 UTC] [V] OFSCtrl angif value:1192 power_val_:20850.000000
[2026-08-01 17:58:11.857 UTC] [V] 485ChCtl <C1> StartDeviceCommunicationForOutputFluctuationSuppressionControlBroadcast 4 cnt:179661, monitor_cnt:128, bc_elapsed:11, min:10, max:40
[2026-08-01 17:58:11.954 UTC] [V] 485ChCtl <C2> set rt:0
[2026-08-01 17:58:11.955 UTC] [V] OFSCtrl limit chk 400 < 800 < [1192->1192] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:11.955 UTC] [V] OFSCtrl angif value:1192 power_val_:20850.000000
[2026-08-01 17:58:11.956 UTC] [V] 485ChCtl <C1> StartDeviceCommunicationForOutputFluctuationSuppressionControlBroadcast 4 cnt:179662, monitor_cnt:129, bc_elapsed:12, min:10, max:40
[2026-08-01 17:58:11.957 UTC] [V] 485DevCtl <C1:05> Dev not PCS IsNeedToChangeOControlState
[2026-08-01 17:58:11.957 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :1
[2026-08-01 17:58:11.957 UTC] [V] 485ChCtl <C1> send request:omron04
[2026-08-01 17:58:11.959 UTC] [D] 485AcReq <C1:05> PutOStream [1][0800050300030014b441]
[2026-08-01 17:58:12.012 UTC] [V] OFSCtrl [/var/local/solajithome/function/output_fluctuation_suppression/batt_data] write success.
[2026-08-01 17:58:12.055 UTC] [V] OFSCtrl limit chk 400 < 800 < [1192->1192] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:12.055 UTC] [V] OFSCtrl angif value:1192 power_val_:20850.000000
[2026-08-01 17:58:12.156 UTC] [V] OFSCtrl limit chk 400 < 800 < [1192->1192] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:12.156 UTC] [V] OFSCtrl angif value:1192 power_val_:20850.000000
[2026-08-01 17:58:12.255 UTC] [V] OFSCtrl limit chk 400 < 800 < [1192->1192] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:12.256 UTC] [V] OFSCtrl angif value:1192 power_val_:20850.000000
[2026-08-01 17:58:12.355 UTC] [V] OFSCtrl limit chk 400 < 800 < [1192->1192] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:12.355 UTC] [V] OFSCtrl angif value:1192 power_val_:20850.000000
[2026-08-01 17:58:12.357 UTC] [V] 485DevCtl <C1:05> AnalyzeResponseData proc restart cnt:17989 UPRstat:0
[2026-08-01 17:58:12.357 UTC] [V] Res no response condition. set normal condition.
[2026-08-01 17:58:12.359 UTC] [D] 485DevCtl <C1:05> RcvDat status[2] len[45] [050328000021d6000013d700001791ffffffd900000258ffffe039ffffffafffffb6b8ffffff4500264cafd49b]
[2026-08-01 17:58:12.359 UTC] [D] 485DevCtl <C1:05> ResCnd OperationId [1] IsNormal[1] 
[2026-08-01 17:58:12.360 UTC] [V] OFSCtrl Rcv set p_pv:-810.000000
[2026-08-01 17:58:12.360 UTC] [V] 485DevCtl <C1:05> [01][601259][-81.000000][2][kW]
[2026-08-01 17:58:12.360 UTC] [V] SummDat SetVrmValue dev_id:5 val:-810.000000 sc:3
[2026-08-01 17:58:12.360 UTC] [V] OCMgr SetMeterValue PhId:0105, branchNo:01, valueId:601259, value:-81.000000, scaleFactor:2, devId:5
[2026-08-01 17:58:12.360 UTC] [V] 485DevCtl <C1:05> [01][603259][2509999.000000][1][kWh]
[2026-08-01 17:58:12.360 UTC] [V] SummDat SetVrmValue dev_id:5 val:2509999.000000 sc:1
[2026-08-01 17:58:12.361 UTC] [V] OCMgr SetMeterValue PhId:0105, branchNo:01, valueId:603259, value:2509999.000000, scaleFactor:1, devId:5
[2026-08-01 17:58:12.361 UTC] [V] 485DevCtl <C1:05> device_type:PV-Meter
[2026-08-01 17:58:12.361 UTC] [V] 485ChCtl <C1> set rt:0
[2026-08-01 17:58:12.455 UTC] [V] OFSCtrl limit chk 400 < 800 < [1192->1192] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:12.455 UTC] [V] OFSCtrl angif value:1192 power_val_:20850.000000
[2026-08-01 17:58:12.456 UTC] [V] 485ChCtl <C1> StartDeviceCommunicationForOutputFluctuationSuppressionControlBroadcast 4 cnt:179667, monitor_cnt:134, bc_elapsed:17, min:10, max:40
[2026-08-01 17:58:12.456 UTC] [V] 485DevCtl <C1:06> Dev not PCS IsNeedToChangeOControlState
[2026-08-01 17:58:12.456 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :1
[2026-08-01 17:58:12.457 UTC] [V] 485ChCtl <C1> send request:omron06
[2026-08-01 17:58:12.458 UTC] [D] 485AcReq <C1:06> PutOStream [1][08000603000000144472]
[2026-08-01 17:58:12.555 UTC] [V] OFSCtrl limit chk 400 < 800 < [1192->1192] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:12.555 UTC] [V] OFSCtrl angif value:1192 power_val_:20850.000000
[2026-08-01 17:58:12.555 UTC] [V] OFSCtrl Control charge discharge proc start.
[2026-08-01 17:58:12.555 UTC] [V] OFSCtrl CHG 20 p_th(t):20897.850000 = p_th_old_:20927.550000 + lev_cd_:-0.300000 * (total_pcs_capacity_:297000.000000 * cof_spec_:2.000000 / 60 * (time_threshold_renew:10.000000 * 10)), min:-2062.500000, max:407900.000000
[2026-08-01 17:58:12.556 UTC] [V] OFSCtrl CHG 21 batt_w:21172.054079 = old:21146.924579 +  kp:0.550000 * e:47.850000 + ki:0.000000 * sume:-13345.199857 + kd:0.040000 * (e:47.850000 - e1:77.550000)
[2026-08-01 17:58:12.556 UTC] [V] OFSCtrl CHG 21 battery threshold min:20000.000000 <= bat:21172.054079 <= max:196000.000000, adjust charge:0.000000, discharge:1000.000000
[2026-08-01 17:58:12.556 UTC] [V] OFSCtrl CHG 29 q:52.000000, mod(round):4.000000
[2026-08-01 17:58:12.557 UTC] [V] OFSCtrl discharge bat_w[0303]:6300.000000 += adjust:1000.000000
[2026-08-01 17:58:12.557 UTC] [D] OFSCtrl battery ctrl val:10.600000
[2026-08-01 17:58:12.557 UTC] [V] 485ChCtl <C3> battery limit on [53.000000,53.000000,63.000000,53.000000,] request.
[2026-08-01 17:58:12.557 UTC] [V] OFSCtrl Control charge discharge proc:01->02->BATT_CHK->03->04->05->06->10->12->13->15->16->18->19->20->21->22->23->24->25->27->23->24->25->27->23->24->25->27->23->24->25->27->28->29->30->31->32->30->31->32->30->31->32->30->31->32->33->34
[2026-08-01 17:58:12.579 UTC] [V] 485ChCtl <C3> battery send request.1
[2026-08-01 17:58:12.580 UTC] [D] VarInf Limit_Bat rt[2]set val[53] set rate[10.600000] value100[500] value-100[-500]
[2026-08-01 17:58:12.581 UTC] [D] VarInf Limit_Bat rt[2]set val[53] set rate[10.600000] value100[500] value-100[-500]
[2026-08-01 17:58:12.587 UTC] [D] VarInf Limit_Bat rt[2]set val[63] set rate[12.600000] value100[500] value-100[-500]
[2026-08-01 17:58:12.600 UTC] [D] VarInf Limit_Bat rt[2]set val[53] set rate[10.600000] value100[500] value-100[-500]
[2026-08-01 17:58:12.610 UTC] [D] 485AcReq <C3:01> PutOStream [6][0f000001000000090110278e0001020035]
[2026-08-01 17:58:12.611 UTC] [D] 485AcReq <C3:02> PutOStream [6][0f000001000000090110278e0001020035]
[2026-08-01 17:58:12.612 UTC] [D] 485AcReq <C3:03> PutOStream [6][0f000001000000090110278e000102003f]
[2026-08-01 17:58:12.612 UTC] [D] 485AcReq <C3:04> PutOStream [6][0f000001000000090110278e0001020035]
[2026-08-01 17:58:12.655 UTC] [V] OFSCtrl limit chk 400 < 800 < [1192->1192] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:12.655 UTC] [V] OFSCtrl angif value:1192 power_val_:20850.000000
[2026-08-01 17:58:12.755 UTC] [V] OFSCtrl limit chk 400 < 800 < [1192->1192] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:12.755 UTC] [V] OFSCtrl angif value:1192 power_val_:20850.000000
[2026-08-01 17:58:12.784 UTC] [V] 485DevCtl <C3:01> AnalyzeResponseData proc restart cnt:17972 UPRstat:0
[2026-08-01 17:58:12.786 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:58:12.787 UTC] [D] 485DevCtl <C3:01> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:58:12.787 UTC] [D] 485DevCtl <C3:01> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:58:12.787 UTC] [V] 485DevCtl <C3:01> device_type:Battery
[2026-08-01 17:58:12.788 UTC] [V] 485DevCtl <C3:02> AnalyzeResponseData proc restart cnt:17972 UPRstat:0
[2026-08-01 17:58:12.789 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:58:12.789 UTC] [D] 485DevCtl <C3:02> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:58:12.789 UTC] [D] 485DevCtl <C3:02> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:58:12.789 UTC] [V] 485DevCtl <C3:02> device_type:Battery
[2026-08-01 17:58:12.790 UTC] [V] 485DevCtl <C3:03> AnalyzeResponseData proc restart cnt:17972 UPRstat:0
[2026-08-01 17:58:12.791 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:58:12.791 UTC] [D] 485DevCtl <C3:03> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:58:12.791 UTC] [D] 485DevCtl <C3:03> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:58:12.792 UTC] [V] 485DevCtl <C3:03> device_type:Battery
[2026-08-01 17:58:12.828 UTC] [V] 485DevCtl <C3:04> AnalyzeResponseData proc restart cnt:17972 UPRstat:0
[2026-08-01 17:58:12.853 UTC] [V] 485DevCtl <C1:06> AnalyzeResponseData proc restart cnt:17990 UPRstat:0
[2026-08-01 17:58:12.853 UTC] [V] Res no response condition. set normal condition.
[2026-08-01 17:58:12.855 UTC] [V] OFSCtrl limit chk 400 < 800 < [1192->1192] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:12.855 UTC] [V] OFSCtrl angif value:1192 power_val_:20850.000000
[2026-08-01 17:58:12.855 UTC] [D] 485DevCtl <C1:06> RcvDat status[2] len[45] [0603280000080400000824000008430000f69d0000f6310000f3d0000000640000025700035d120000089c7059]
[2026-08-01 17:58:12.855 UTC] [D] 485DevCtl <C1:06> ResCnd OperationId [1] IsNormal[1] 
[2026-08-01 17:58:12.856 UTC] [V] OFSCtrl Rcv set p_batt:22040.000000
[2026-08-01 17:58:12.856 UTC] [V] 485DevCtl <C1:06> [01][601237][2204.000000][2][kW]
[2026-08-01 17:58:12.856 UTC] [V] SummDat SetVrmValue dev_id:6 val:22040.000000 sc:3
[2026-08-01 17:58:12.856 UTC] [V] OCMgr SetMeterValue PhId:0106, branchNo:01, valueId:601237, value:2204.000000, scaleFactor:2, devId:6
[2026-08-01 17:58:12.857 UTC] [V] 485DevCtl <C1:06> device_type:Batt-Meter
[2026-08-01 17:58:12.857 UTC] [V] 485ChCtl <C1> set rt:0
[2026-08-01 17:58:12.858 UTC] [D] 485ChCtl <C1> monitoring dev All Send
[2026-08-01 17:58:12.859 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:58:12.864 UTC] [D] 485DevCtl <C3:04> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:58:12.864 UTC] [D] 485DevCtl <C3:04> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:58:12.871 UTC] [V] 485DevCtl <C3:04> device_type:Battery
[2026-08-01 17:58:12.877 UTC] [V] 485ChCtl <C3> set rt:0
[2026-08-01 17:58:12.956 UTC] [V] OFSCtrl limit chk 400 < 800 < [1192->1192] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:12.956 UTC] [V] OFSCtrl angif value:1192 power_val_:20850.000000
[2026-08-01 17:58:13.012 UTC] [V] OFSCtrl [/var/local/solajithome/function/output_fluctuation_suppression/batt_data] write success.
[2026-08-01 17:58:13.055 UTC] [V] OFSCtrl limit chk 400 < 800 < [1192->1192] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:13.055 UTC] [V] OFSCtrl angif value:1192 power_val_:20850.000000
[2026-08-01 17:58:13.155 UTC] [V] OFSCtrl limit chk 400 < 800 < [1192->1192] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:13.155 UTC] [V] OFSCtrl angif value:1192 power_val_:20850.000000
[2026-08-01 17:58:13.255 UTC] [V] OFSCtrl limit chk 400 < 800 < [1192->1192] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:13.255 UTC] [V] OFSCtrl angif value:1192 power_val_:20850.000000
[2026-08-01 17:58:13.355 UTC] [V] OFSCtrl limit chk 400 < 800 < [1192->1192] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:13.355 UTC] [V] OFSCtrl angif value:1192 power_val_:20850.000000
[2026-08-01 17:58:13.455 UTC] [V] OFSCtrl limit chk 400 < 800 < [1192->1192] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:13.455 UTC] [V] OFSCtrl angif value:1192 power_val_:20850.000000
[2026-08-01 17:58:13.555 UTC] [V] OFSCtrl limit chk 400 < 800 < [1192->1192] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:13.555 UTC] [V] OFSCtrl angif value:1192 power_val_:20850.000000
[2026-08-01 17:58:13.555 UTC] [V] OFSCtrl Control charge discharge proc start.
[2026-08-01 17:58:13.555 UTC] [V] OFSCtrl CHG 20 p_th(t):20868.150000 = p_th_old_:20897.850000 + lev_cd_:-0.300000 * (total_pcs_capacity_:297000.000000 * cof_spec_:2.000000 / 60 * (time_threshold_renew:10.000000 * 10)), min:-2062.500000, max:407900.000000
[2026-08-01 17:58:13.556 UTC] [V] OFSCtrl CHG 21 batt_w:21180.848579 = old:21172.054079 +  kp:0.550000 * e:18.150000 + ki:0.000000 * sume:-13327.049857 + kd:0.040000 * (e:18.150000 - e1:47.850000)
[2026-08-01 17:58:13.557 UTC] [V] OFSCtrl CHG 21 battery threshold min:20000.000000 <= bat:21180.848579 <= max:196000.000000, adjust charge:0.000000, discharge:1000.000000
[2026-08-01 17:58:13.557 UTC] [V] OFSCtrl CHG 29 q:52.000000, mod(round):4.000000
[2026-08-01 17:58:13.557 UTC] [V] OFSCtrl discharge bat_w[0303]:6300.000000 += adjust:1000.000000
[2026-08-01 17:58:13.558 UTC] [D] OFSCtrl battery ctrl val:10.600000
[2026-08-01 17:58:13.558 UTC] [V] 485ChCtl <C3> battery limit on [53.000000,53.000000,63.000000,53.000000,] request.
[2026-08-01 17:58:13.558 UTC] [V] OFSCtrl Control charge discharge proc:01->02->BATT_CHK->03->04->05->06->10->12->13->15->16->18->19->20->21->22->23->24->25->27->23->24->25->27->23->24->25->27->23->24->25->27->28->29->30->31->32->30->31->32->30->31->32->30->31->32->33->34
[2026-08-01 17:58:13.578 UTC] [V] 485ChCtl <C3> battery send request.1
[2026-08-01 17:58:13.579 UTC] [D] VarInf Limit_Bat rt[2]set val[53] set rate[10.600000] value100[500] value-100[-500]
[2026-08-01 17:58:13.580 UTC] [D] VarInf Limit_Bat rt[2]set val[53] set rate[10.600000] value100[500] value-100[-500]
[2026-08-01 17:58:13.581 UTC] [D] VarInf Limit_Bat rt[2]set val[63] set rate[12.600000] value100[500] value-100[-500]
[2026-08-01 17:58:13.597 UTC] [D] VarInf Limit_Bat rt[2]set val[53] set rate[10.600000] value100[500] value-100[-500]
[2026-08-01 17:58:13.613 UTC] [D] 485AcReq <C3:01> PutOStream [6][0f000001000000090110278e0001020035]
[2026-08-01 17:58:13.614 UTC] [D] 485AcReq <C3:02> PutOStream [6][0f000001000000090110278e0001020035]
[2026-08-01 17:58:13.615 UTC] [D] 485AcReq <C3:03> PutOStream [6][0f000001000000090110278e000102003f]
[2026-08-01 17:58:13.616 UTC] [D] 485AcReq <C3:04> PutOStream [6][0f000001000000090110278e0001020035]
[2026-08-01 17:58:13.655 UTC] [V] OFSCtrl limit chk 400 < 800 < [1192->1192] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:13.655 UTC] [V] OFSCtrl angif value:1192 power_val_:20850.000000
[2026-08-01 17:58:13.755 UTC] [V] OFSCtrl limit chk 400 < 800 < [1192->1192] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:13.755 UTC] [V] OFSCtrl angif value:1192 power_val_:20850.000000
[2026-08-01 17:58:13.804 UTC] [V] 485DevCtl <C3:01> AnalyzeResponseData proc restart cnt:17973 UPRstat:0
[2026-08-01 17:58:13.806 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:58:13.807 UTC] [D] 485DevCtl <C3:01> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:58:13.807 UTC] [D] 485DevCtl <C3:01> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:58:13.807 UTC] [V] 485DevCtl <C3:01> device_type:Battery
[2026-08-01 17:58:13.808 UTC] [V] 485DevCtl <C3:02> AnalyzeResponseData proc restart cnt:17973 UPRstat:0
[2026-08-01 17:58:13.819 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:58:13.824 UTC] [D] 485DevCtl <C3:02> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:58:13.825 UTC] [D] 485DevCtl <C3:02> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:58:13.827 UTC] [V] 485DevCtl <C3:02> device_type:Battery
[2026-08-01 17:58:13.832 UTC] [V] 485DevCtl <C3:03> AnalyzeResponseData proc restart cnt:17973 UPRstat:0
[2026-08-01 17:58:13.840 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:58:13.840 UTC] [D] 485DevCtl <C3:03> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:58:13.840 UTC] [D] 485DevCtl <C3:03> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:58:13.841 UTC] [V] 485DevCtl <C3:03> device_type:Battery
[2026-08-01 17:58:13.841 UTC] [V] 485DevCtl <C3:04> AnalyzeResponseData proc restart cnt:17973 UPRstat:0
[2026-08-01 17:58:13.855 UTC] [V] OFSCtrl limit chk 400 < 800 < [1192->1192] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:13.855 UTC] [V] OFSCtrl angif value:1192 power_val_:20850.000000
[2026-08-01 17:58:13.857 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:58:13.863 UTC] [D] 485DevCtl <C3:04> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:58:13.865 UTC] [D] 485DevCtl <C3:04> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:58:13.866 UTC] [V] 485DevCtl <C3:04> device_type:Battery
[2026-08-01 17:58:13.869 UTC] [V] 485ChCtl <C3> set rt:0
[2026-08-01 17:58:13.955 UTC] [V] OFSCtrl limit chk 400 < 800 < [1192->1192] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:13.955 UTC] [V] OFSCtrl angif value:1192 power_val_:20850.000000
[2026-08-01 17:58:14.012 UTC] [V] OFSCtrl [/var/local/solajithome/function/output_fluctuation_suppression/batt_data] write success.
[2026-08-01 17:58:14.055 UTC] [V] OFSCtrl limit chk 400 < 800 < [1192->1192] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:14.055 UTC] [V] OFSCtrl angif value:1192 power_val_:20850.000000
[2026-08-01 17:58:14.155 UTC] [V] OFSCtrl limit chk 400 < 800 < [1192->1192] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:14.155 UTC] [V] OFSCtrl angif value:1192 power_val_:20850.000000
[2026-08-01 17:58:14.255 UTC] [V] OFSCtrl limit chk 400 < 800 < [1192->1192] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:14.255 UTC] [V] OFSCtrl angif value:1192 power_val_:20850.000000
[2026-08-01 17:58:14.355 UTC] [V] OFSCtrl limit chk 400 < 800 < [1192->1192] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:14.356 UTC] [V] OFSCtrl angif value:1192 power_val_:20850.000000
[2026-08-01 17:58:14.455 UTC] [V] OFSCtrl limit chk 400 < 800 < [1191->1191] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:14.455 UTC] [V] OFSCtrl angif value:1191 power_val_:20643.750000
[2026-08-01 17:58:14.464 UTC] [V] 485ChCtl <C2> StartDeviceCommunicationForOutputFluctuationSuppressionControlBroadcast 4 cnt:179687, monitor_cnt:50, bc_elapsed:179687, min:10, max:40
[2026-08-01 17:58:14.465 UTC] [V] OFSCtrl /var/local/solajithome/function/output_fluctuation_suppression/state is exist:0
[2026-08-01 17:58:14.465 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :9
[2026-08-01 17:58:14.466 UTC] [V] 485ChCtl <C2> send request:Sungrow08
[2026-08-01 17:58:14.466 UTC] [D] 485AcReq <C2:01> PutOStream [9][0800010413fa001794b1]
[2026-08-01 17:58:14.555 UTC] [V] OFSCtrl limit chk 400 < 800 < [1192->1192] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:14.555 UTC] [V] OFSCtrl angif value:1192 power_val_:20850.000000
[2026-08-01 17:58:14.555 UTC] [V] OFSCtrl Control charge discharge proc start.
[2026-08-01 17:58:14.556 UTC] [V] OFSCtrl CHG 20 p_th(t):20838.450000 = p_th_old_:20868.150000 + lev_cd_:-0.300000 * (total_pcs_capacity_:297000.000000 * cof_spec_:2.000000 / 60 * (time_threshold_renew:10.000000 * 10)), min:-2062.500000, max:407900.000000
[2026-08-01 17:58:14.557 UTC] [V] OFSCtrl CHG 21 batt_w:21173.308079 = old:21180.848579 +  kp:0.550000 * e:-11.550000 + ki:0.000000 * sume:-13338.599857 + kd:0.040000 * (e:-11.550000 - e1:18.150000)
[2026-08-01 17:58:14.557 UTC] [V] OFSCtrl CHG 21 battery threshold min:20000.000000 <= bat:21173.308079 <= max:196000.000000, adjust charge:0.000000, discharge:1000.000000
[2026-08-01 17:58:14.558 UTC] [V] OFSCtrl CHG 29 q:52.000000, mod(round):4.000000
[2026-08-01 17:58:14.559 UTC] [V] OFSCtrl discharge bat_w[0303]:6300.000000 += adjust:1000.000000
[2026-08-01 17:58:14.559 UTC] [D] OFSCtrl battery ctrl val:10.600000
[2026-08-01 17:58:14.565 UTC] [V] 485ChCtl <C3> battery limit on [53.000000,53.000000,63.000000,53.000000,] request.
[2026-08-01 17:58:14.566 UTC] [V] OFSCtrl Control charge discharge proc:01->02->BATT_CHK->03->04->05->06->10->12->13->15->16->18->19->20->21->22->23->24->25->27->23->24->25->27->23->24->25->27->23->24->25->27->28->29->30->31->32->30->31->32->30->31->32->30->31->32->33->34
[2026-08-01 17:58:14.579 UTC] [V] 485ChCtl <C3> battery send request.1
[2026-08-01 17:58:14.580 UTC] [D] VarInf Limit_Bat rt[2]set val[53] set rate[10.600000] value100[500] value-100[-500]
[2026-08-01 17:58:14.580 UTC] [D] VarInf Limit_Bat rt[2]set val[53] set rate[10.600000] value100[500] value-100[-500]
[2026-08-01 17:58:14.586 UTC] [D] VarInf Limit_Bat rt[2]set val[63] set rate[12.600000] value100[500] value-100[-500]
[2026-08-01 17:58:14.600 UTC] [D] VarInf Limit_Bat rt[2]set val[53] set rate[10.600000] value100[500] value-100[-500]
[2026-08-01 17:58:14.610 UTC] [D] 485AcReq <C3:01> PutOStream [6][0f000001000000090110278e0001020035]
[2026-08-01 17:58:14.610 UTC] [D] 485AcReq <C3:02> PutOStream [6][0f000001000000090110278e0001020035]
[2026-08-01 17:58:14.611 UTC] [D] 485AcReq <C3:03> PutOStream [6][0f000001000000090110278e000102003f]
[2026-08-01 17:58:14.611 UTC] [D] 485AcReq <C3:04> PutOStream [6][0f000001000000090110278e0001020035]
[2026-08-01 17:58:14.655 UTC] [V] OFSCtrl limit chk 400 < 800 < [1192->1192] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:14.655 UTC] [V] OFSCtrl angif value:1192 power_val_:20850.000000
[2026-08-01 17:58:14.755 UTC] [V] OFSCtrl limit chk 400 < 800 < [1192->1192] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:14.755 UTC] [V] OFSCtrl angif value:1192 power_val_:20850.000000
[2026-08-01 17:58:14.774 UTC] [V] 485DevCtl <C3:01> AnalyzeResponseData proc restart cnt:17974 UPRstat:0
[2026-08-01 17:58:14.776 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:58:14.777 UTC] [D] 485DevCtl <C3:01> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:58:14.777 UTC] [D] 485DevCtl <C3:01> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:58:14.777 UTC] [V] 485DevCtl <C3:01> device_type:Battery
[2026-08-01 17:58:14.783 UTC] [V] 485DevCtl <C3:02> AnalyzeResponseData proc restart cnt:17974 UPRstat:0
[2026-08-01 17:58:14.803 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:58:14.811 UTC] [D] 485DevCtl <C3:02> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:58:14.811 UTC] [D] 485DevCtl <C3:02> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:58:14.811 UTC] [V] 485DevCtl <C3:02> device_type:Battery
[2026-08-01 17:58:14.824 UTC] [V] 485DevCtl <C3:03> AnalyzeResponseData proc restart cnt:17974 UPRstat:0
[2026-08-01 17:58:14.828 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:58:14.829 UTC] [D] 485DevCtl <C3:03> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:58:14.829 UTC] [D] 485DevCtl <C3:03> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:58:14.829 UTC] [V] 485DevCtl <C3:03> device_type:Battery
[2026-08-01 17:58:14.829 UTC] [V] 485DevCtl <C3:04> AnalyzeResponseData proc restart cnt:17974 UPRstat:0
[2026-08-01 17:58:14.831 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:58:14.839 UTC] [V] Res no response condition. set normal condition.
[2026-08-01 17:58:14.841 UTC] [D] 485DevCtl <C2:01> RcvDat status[2] len[51] [01042e000000000000000000000000ffffffffffffffff03e8ffffffff083a0000ffffffffffffffffffffffffffffffffce69]
[2026-08-01 17:58:14.841 UTC] [D] 485DevCtl <C2:01> ResCnd OperationId [9] IsNormal[1] 
[2026-08-01 17:58:14.842 UTC] [V] 485DevCtl <C2:01> [04][101100][0.000000][1][V]
[2026-08-01 17:58:14.842 UTC] [V] SummDat SetVrmValue dev_id:7 val:0.000000 sc:3
[2026-08-01 17:58:14.843 UTC] [V] OCMgr SetMeterValue PhId:0201, branchNo:04, valueId:101100, value:0.000000, scaleFactor:1, devId:7
[2026-08-01 17:58:14.843 UTC] [V] 485DevCtl <C2:01> [04][101101][0.000000][1][A]
[2026-08-01 17:58:14.843 UTC] [V] SummDat SetVrmValue dev_id:7 val:0.000000 sc:3
[2026-08-01 17:58:14.844 UTC] [V] OCMgr SetMeterValue PhId:0201, branchNo:04, valueId:101101, value:0.000000, scaleFactor:1, devId:7
[2026-08-01 17:58:14.844 UTC] [V] 485DevCtl <C2:01> [05][101100][0.000000][1][V]
[2026-08-01 17:58:14.856 UTC] [V] OFSCtrl limit chk 400 < 800 < [1192->1192] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:14.856 UTC] [V] OFSCtrl angif value:1192 power_val_:20850.000000
[2026-08-01 17:58:14.855 UTC] [V] SummDat SetVrmValue dev_id:7 val:0.000000 sc:3
[2026-08-01 17:58:14.860 UTC] [V] OCMgr SetMeterValue PhId:0201, branchNo:05, valueId:101100, value:0.000000, scaleFactor:1, devId:7
[2026-08-01 17:58:14.861 UTC] [V] 485DevCtl <C2:01> [05][101101][0.000000][1][A]
[2026-08-01 17:58:14.861 UTC] [V] SummDat SetVrmValue dev_id:7 val:0.000000 sc:3
[2026-08-01 17:58:14.861 UTC] [V] OCMgr SetMeterValue PhId:0201, branchNo:05, valueId:101101, value:0.000000, scaleFactor:1, devId:7
[2026-08-01 17:58:14.861 UTC] [V] 485DevCtl <C2:01> [06][101100][0.000000][1][V]
[2026-08-01 17:58:14.861 UTC] [V] SummDat SetVrmValue dev_id:7 val:0.000000 sc:3
[2026-08-01 17:58:14.862 UTC] [V] OCMgr SetMeterValue PhId:0201, branchNo:06, valueId:101100, value:0.000000, scaleFactor:1, devId:7
[2026-08-01 17:58:14.878 UTC] [D] 485DevCtl <C3:04> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:58:14.881 UTC] [D] 485DevCtl <C3:04> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:58:14.883 UTC] [V] 485DevCtl <C2:01> [06][101101][0.000000][1][A]
[2026-08-01 17:58:14.886 UTC] [V] SummDat SetVrmValue dev_id:7 val:0.000000 sc:3
[2026-08-01 17:58:14.884 UTC] [V] 485DevCtl <C3:04> device_type:Battery
[2026-08-01 17:58:14.892 UTC] [V] 485ChCtl <C3> set rt:0
[2026-08-01 17:58:14.898 UTC] [V] OCMgr SetMeterValue PhId:0201, branchNo:06, valueId:101101, value:0.000000, scaleFactor:1, devId:7
[2026-08-01 17:58:14.899 UTC] [V] 485DevCtl <C2:01> device_type:PV-PCS
[2026-08-01 17:58:14.903 UTC] [V] 485ChCtl <C2> set rt:0
[2026-08-01 17:58:14.955 UTC] [V] OFSCtrl limit chk 400 < 800 < [1192->1192] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:14.955 UTC] [V] OFSCtrl angif value:1192 power_val_:20850.000000
[2026-08-01 17:58:14.964 UTC] [V] 485ChCtl <C2> StartDeviceCommunicationForOutputFluctuationSuppressionControlBroadcast 4 cnt:179692, monitor_cnt:55, bc_elapsed:179692, min:10, max:40
[2026-08-01 17:58:14.964 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :9
[2026-08-01 17:58:14.965 UTC] [V] 485ChCtl <C2> send request:Sungrow08
[2026-08-01 17:58:14.966 UTC] [D] 485AcReq <C2:02> PutOStream [9][0800020413fa00179482]
[2026-08-01 17:58:15.013 UTC] [V] OFSCtrl [/var/local/solajithome/function/output_fluctuation_suppression/batt_data] write success.
[2026-08-01 17:58:15.055 UTC] [V] OFSCtrl limit chk 400 < 800 < [1192->1192] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:15.055 UTC] [V] OFSCtrl angif value:1192 power_val_:20850.000000
[2026-08-01 17:58:15.078 UTC] [V] 485ChCtl <C3> StartDeviceCommunicationForOutputFluctuationSuppressionControlBroadcast 4 cnt:179693, monitor_cnt:50, bc_elapsed:179693, min:10, max:40
[2026-08-01 17:58:15.079 UTC] [V] OFSCtrl /var/local/solajithome/function/output_fluctuation_suppression/state is exist:0
[2026-08-01 17:58:15.079 UTC] [V] 485DevCtl <C3:01> Dev not PCS IsNeedToChangeOControlState
[2026-08-01 17:58:15.079 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :1
[2026-08-01 17:58:15.080 UTC] [V] 485ChCtl <C3> send request:Sungrow11
[2026-08-01 17:58:15.080 UTC] [D] 485AcReq <C3:01> PutOStream [1][0c00000100000006010327470048]
[2026-08-01 17:58:15.155 UTC] [V] OFSCtrl limit chk 400 < 800 < [1192->1192] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:15.155 UTC] [V] OFSCtrl angif value:1192 power_val_:20850.000000
[2026-08-01 17:58:15.233 UTC] [V] 485DevCtl <C3:01> AnalyzeResponseData proc restart cnt:17974 UPRstat:0
[2026-08-01 17:58:15.255 UTC] [V] OFSCtrl limit chk 400 < 800 < [1192->1192] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:15.255 UTC] [V] OFSCtrl angif value:1192 power_val_:20850.000000
[2026-08-01 17:58:15.266 UTC] [D] 485DevCtl <C3:01> RcvDat status[0] len[153] [0001000000930103900000000000000000005500550000005500aa00a000fa000000fa0001000000000000000000000019ffffffffffffffffffffffffffffffffffffffffffff000100000000ffff0000ffffffffffffffffffffffffffffffffffff0fa0177003e800000e101388000a000a00000000195020d000000000000000550055fffb0032ffff0000000000000000000000000035]
[2026-08-01 17:58:15.268 UTC] [D] 485DevCtl <C3:01> ResCnd OperationId [1] IsNormal[1]  ConditionType [lggrdev:Normal] Action[-1]
[2026-08-01 17:58:15.273 UTC] [V] 485DevCtl <C3:01> [01][753049][0.000000][0][]
[2026-08-01 17:58:15.275 UTC] [V] SummDat SetVrmValue dev_id:13 val:0.000000 sc:0
[2026-08-01 17:58:15.280 UTC] [V] OCMgr SetMeterValue PhId:0301, branchNo:01, valueId:753049, value:0.000000, scaleFactor:0, devId:13
[2026-08-01 17:58:15.284 UTC] [V] OFSCtrl Rcv set BATT(t-1)[0301]:0.106000 value:5300.000000/50000 BATT(t-1):0.111000 <- 22200.000000/200000
[2026-08-01 17:58:15.284 UTC] [V] 485DevCtl <C3:01> [01][753102][53.000000][1][kW]
[2026-08-01 17:58:15.285 UTC] [V] SummDat SetVrmValue dev_id:13 val:53.000000 sc:1
[2026-08-01 17:58:15.289 UTC] [V] OCMgr SetMeterValue PhId:0301, branchNo:01, valueId:753102, value:53.000000, scaleFactor:1, devId:13
[2026-08-01 17:58:15.296 UTC] [V] 485DevCtl <C3:01> device_type:Battery
[2026-08-01 17:58:15.318 UTC] [V] 485ChCtl <C3> set rt:0
[2026-08-01 17:58:15.339 UTC] [V] Res no response condition. set normal condition.
[2026-08-01 17:58:15.340 UTC] [D] 485DevCtl <C2:02> RcvDat status[2] len[51] [02042e000000000000000000000000ffffffffffffffff03e8ffffffff082a0000ffffffffffffffffffffffffffffffff7ddd]
[2026-08-01 17:58:15.341 UTC] [D] 485DevCtl <C2:02> ResCnd OperationId [9] IsNormal[1] 
[2026-08-01 17:58:15.341 UTC] [V] 485DevCtl <C2:02> [04][101100][0.000000][1][V]
[2026-08-01 17:58:15.341 UTC] [V] SummDat SetVrmValue dev_id:8 val:0.000000 sc:3
[2026-08-01 17:58:15.342 UTC] [V] OCMgr SetMeterValue PhId:0202, branchNo:04, valueId:101100, value:0.000000, scaleFactor:1, devId:8
[2026-08-01 17:58:15.351 UTC] [V] 485DevCtl <C2:02> [04][101101][0.000000][1][A]
[2026-08-01 17:58:15.352 UTC] [V] SummDat SetVrmValue dev_id:8 val:0.000000 sc:3
[2026-08-01 17:58:15.356 UTC] [V] OFSCtrl limit chk 400 < 800 < [1192->1192] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:15.356 UTC] [V] OFSCtrl angif value:1192 power_val_:20850.000000
[2026-08-01 17:58:15.358 UTC] [V] OCMgr SetMeterValue PhId:0202, branchNo:04, valueId:101101, value:0.000000, scaleFactor:1, devId:8
[2026-08-01 17:58:15.370 UTC] [V] 485DevCtl <C2:02> [05][101100][0.000000][1][V]
[2026-08-01 17:58:15.370 UTC] [V] SummDat SetVrmValue dev_id:8 val:0.000000 sc:3
[2026-08-01 17:58:15.376 UTC] [V] OCMgr SetMeterValue PhId:0202, branchNo:05, valueId:101100, value:0.000000, scaleFactor:1, devId:8
[2026-08-01 17:58:15.379 UTC] [V] 485ChCtl <C3> StartDeviceCommunicationForOutputFluctuationSuppressionControlBroadcast 4 cnt:179696, monitor_cnt:53, bc_elapsed:179696, min:10, max:40
[2026-08-01 17:58:15.379 UTC] [V] 485DevCtl <C3:02> Dev not PCS IsNeedToChangeOControlState
[2026-08-01 17:58:15.379 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :4
[2026-08-01 17:58:15.380 UTC] [V] 485ChCtl <C3> send request:Sungrow11
[2026-08-01 17:58:15.381 UTC] [D] 485AcReq <C3:02> PutOStream [4][0c00000100000006010427f0002f]
[2026-08-01 17:58:15.384 UTC] [V] 485DevCtl <C2:02> [05][101101][0.000000][1][A]
[2026-08-01 17:58:15.386 UTC] [V] SummDat SetVrmValue dev_id:8 val:0.000000 sc:3
[2026-08-01 17:58:15.405 UTC] [V] OCMgr SetMeterValue PhId:0202, branchNo:05, valueId:101101, value:0.000000, scaleFactor:1, devId:8
[2026-08-01 17:58:15.405 UTC] [V] 485DevCtl <C2:02> [06][101100][0.000000][1][V]
[2026-08-01 17:58:15.405 UTC] [V] SummDat SetVrmValue dev_id:8 val:0.000000 sc:3
[2026-08-01 17:58:15.406 UTC] [V] OCMgr SetMeterValue PhId:0202, branchNo:06, valueId:101100, value:0.000000, scaleFactor:1, devId:8
[2026-08-01 17:58:15.406 UTC] [V] 485DevCtl <C2:02> [06][101101][0.000000][1][A]
[2026-08-01 17:58:15.406 UTC] [V] SummDat SetVrmValue dev_id:8 val:0.000000 sc:3
[2026-08-01 17:58:15.406 UTC] [V] OCMgr SetMeterValue PhId:0202, branchNo:06, valueId:101101, value:0.000000, scaleFactor:1, devId:8
[2026-08-01 17:58:15.430 UTC] [V] 485DevCtl <C2:02> device_type:PV-PCS
[2026-08-01 17:58:15.443 UTC] [V] 485ChCtl <C2> set rt:0
[2026-08-01 17:58:15.455 UTC] [V] OFSCtrl limit chk 400 < 800 < [1192->1192] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:15.456 UTC] [V] OFSCtrl angif value:1192 power_val_:20850.000000
[2026-08-01 17:58:15.465 UTC] [V] 485ChCtl <C2> StartDeviceCommunicationForOutputFluctuationSuppressionControlBroadcast 4 cnt:179697, monitor_cnt:60, bc_elapsed:179697, min:10, max:40
[2026-08-01 17:58:15.465 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :9
[2026-08-01 17:58:15.466 UTC] [V] 485ChCtl <C2> send request:Sungrow08
[2026-08-01 17:58:15.466 UTC] [D] 485AcReq <C2:03> PutOStream [9][0800030413fa00179553]
[2026-08-01 17:58:15.555 UTC] [V] OFSCtrl limit chk 400 < 800 < [1192->1192] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:15.555 UTC] [V] OFSCtrl angif value:1192 power_val_:20850.000000
[2026-08-01 17:58:15.555 UTC] [V] OFSCtrl Control charge discharge proc start.
[2026-08-01 17:58:15.556 UTC] [V] OFSCtrl CHG 20 p_th(t):20808.750000 = p_th_old_:20838.450000 + lev_cd_:-0.300000 * (total_pcs_capacity_:297000.000000 * cof_spec_:2.000000 / 60 * (time_threshold_renew:10.000000 * 10)), min:-2062.500000, max:407900.000000
[2026-08-01 17:58:15.556 UTC] [V] OFSCtrl CHG 21 batt_w:21149.432579 = old:21173.308079 +  kp:0.550000 * e:-41.250000 + ki:0.000000 * sume:-13379.849857 + kd:0.040000 * (e:-41.250000 - e1:-11.550000)
[2026-08-01 17:58:15.557 UTC] [V] OFSCtrl CHG 21 battery threshold min:20000.000000 <= bat:21149.432579 <= max:196000.000000, adjust charge:0.000000, discharge:1000.000000
[2026-08-01 17:58:15.557 UTC] [V] OFSCtrl CHG 29 q:52.000000, mod(round):3.000000
[2026-08-01 17:58:15.557 UTC] [V] OFSCtrl discharge bat_w[0303]:6300.000000 += adjust:1000.000000
[2026-08-01 17:58:15.557 UTC] [D] OFSCtrl battery ctrl val:10.600000
[2026-08-01 17:58:15.558 UTC] [V] 485ChCtl <C3> battery limit on [53.000000,53.000000,63.000000,52.000000,] request.
[2026-08-01 17:58:15.558 UTC] [V] OFSCtrl Control charge discharge proc:01->02->BATT_CHK->03->04->05->06->10->12->13->15->16->18->19->20->21->22->23->24->25->27->23->24->25->27->23->24->25->27->23->24->25->27->28->29->30->31->32->30->31->32->30->31->32->30->31->32->33->34
[2026-08-01 17:58:15.573 UTC] [V] 485DevCtl <C3:02> AnalyzeResponseData proc restart cnt:17974 UPRstat:0
[2026-08-01 17:58:15.577 UTC] [D] 485DevCtl <C3:02> RcvDat status[0] len[103] [00010000006101045e1ea2004800370ffd0fc0103a004e004f004c003600000000000000000000000000000001000000b06fb6000065b60000012c0000006700ac244200000001177103e701d6000000ac03620000137f0000f78c000100360000000000b00000]
[2026-08-01 17:58:15.577 UTC] [D] 485DevCtl <C3:02> ResCnd OperationId [4] IsNormal[1]  ConditionType [lggrdev:Normal] Action[-1]
[2026-08-01 17:58:15.578 UTC] [V] 485DevCtl <C3:02> [05][753053][0.000000][0][]
[2026-08-01 17:58:15.578 UTC] [V] SummDat SetVrmValue dev_id:14 val:0.000000 sc:0
[2026-08-01 17:58:15.578 UTC] [V] OCMgr SetMeterValue PhId:0302, branchNo:05, valueId:753053, value:0.000000, scaleFactor:0, devId:14
[2026-08-01 17:58:15.579 UTC] [V] 485DevCtl <C3:02> [06][753053][0.000000][0][]
[2026-08-01 17:58:15.579 UTC] [V] SummDat SetVrmValue dev_id:14 val:0.000000 sc:0
[2026-08-01 17:58:15.584 UTC] [V] OCMgr SetMeterValue PhId:0302, branchNo:06, valueId:753053, value:0.000000, scaleFactor:0, devId:14
[2026-08-01 17:58:15.589 UTC] [V] 485DevCtl <C3:02> [07][753053][0.000000][0][]
[2026-08-01 17:58:15.592 UTC] [V] SummDat SetVrmValue dev_id:14 val:0.000000 sc:0
[2026-08-01 17:58:15.601 UTC] [V] OCMgr SetMeterValue PhId:0302, branchNo:07, valueId:753053, value:0.000000, scaleFactor:0, devId:14
[2026-08-01 17:58:15.609 UTC] [V] 485DevCtl <C3:02> device_type:Battery
[2026-08-01 17:58:15.619 UTC] [V] 485DevCtl <C3:02> set2 StatusCode[020101]
[2026-08-01 17:58:15.620 UTC] [V] OFSCtrl Bat[0302] StCd[020101]->st[1].
[2026-08-01 17:58:15.627 UTC] [V] OFSCtrl set batt status:[0302]:Drive, All:[0301]:Drive,[0302]:Drive,[0303]:Drive,[0304]:Drive, [DRIVE] 
[2026-08-01 17:58:15.632 UTC] [V] OFSCtrl change set SOC(t):44.750000 drive cnt:4
[2026-08-01 17:58:15.633 UTC] [V] 485DevCtl <C3:02> set2 StatusCode[020101] DeviceName[蓄電池2] DeviceNumber[1]
[2026-08-01 17:58:15.634 UTC] [V] 485ChCtl <C3> set rt:0
[2026-08-01 17:58:15.655 UTC] [V] OFSCtrl limit chk 400 < 800 < [1192->1192] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:15.656 UTC] [V] OFSCtrl angif value:1192 power_val_:20850.000000
[2026-08-01 17:58:15.679 UTC] [V] 485ChCtl <C3> battery send request.1
[2026-08-01 17:58:15.680 UTC] [D] VarInf Limit_Bat rt[2]set val[53] set rate[10.600000] value100[500] value-100[-500]
[2026-08-01 17:58:15.682 UTC] [D] VarInf Limit_Bat rt[2]set val[53] set rate[10.600000] value100[500] value-100[-500]
[2026-08-01 17:58:15.683 UTC] [D] VarInf Limit_Bat rt[2]set val[63] set rate[12.600000] value100[500] value-100[-500]
[2026-08-01 17:58:15.694 UTC] [D] VarInf Limit_Bat rt[2]set val[52] set rate[10.400000] value100[500] value-100[-500]
[2026-08-01 17:58:15.703 UTC] [D] 485AcReq <C3:01> PutOStream [6][0f000001000000090110278e0001020035]
[2026-08-01 17:58:15.704 UTC] [D] 485AcReq <C3:02> PutOStream [6][0f000001000000090110278e0001020035]
[2026-08-01 17:58:15.705 UTC] [D] 485AcReq <C3:03> PutOStream [6][0f000001000000090110278e000102003f]
[2026-08-01 17:58:15.705 UTC] [D] 485AcReq <C3:04> PutOStream [6][0f000001000000090110278e0001020034]
[2026-08-01 17:58:15.739 UTC] [V] OC485DevMgr TargetPowerPolling 
[2026-08-01 17:58:15.739 UTC] [V] OC485DevMgr TargetPowerPolling Target power no ud current[20260801173000]now[20260801175815]next[20260801180000]
[2026-08-01 17:58:15.739 UTC] [V] OCMgr UpdateExtCurrentTarget call
[2026-08-01 17:58:15.739 UTC] [V] OCMgr UpdateExtSchedule call
[2026-08-01 17:58:15.740 UTC] [V] OCMgr UpdateExtSchedule file none. ext rate:-1, time:20200101000000
[2026-08-01 17:58:15.740 UTC] [V] OCMgr IsPvocdScheduleError 0
[2026-08-01 17:58:15.740 UTC] [V] OCMgr UpdateExtCurrentTarget check schedule:0, ext rate:-1
[2026-08-01 17:58:15.740 UTC] [V] OCMgr CalcOutputControlPower pow:297.000000, rate:100, cap:297.000000
[2026-08-01 17:58:15.740 UTC] [V] OCMgr IsPvocdScheduleError 0
[2026-08-01 17:58:15.741 UTC] [D] OCMgr UpdateExtCurrentTarget external none, in_pow:297.000000, 297.000000
[2026-08-01 17:58:15.741 UTC] [V] OCMgr CalcOutputControlRate rate:100, pow:297.000000, cap:297.000000, rate_out:297.000000
[2026-08-01 17:58:15.741 UTC] [V] OCMgr WriteExtSchedule dat:100,20260802030000
[2026-08-01 17:58:15.744 UTC] [V] FlUtil write csv file[/media/sdcard/solajithome/Log/modbus/ExecSchedulePath/ExecEmsSchedule.csv] result:1
[2026-08-01 17:58:15.745 UTC] [V] OCMgr now time:20260801173000, power_value:297.000000, rt:0
[2026-08-01 17:58:15.746 UTC] [V] OCMgr next time:20260801180000, power_value:297.000000, rt:0
[2026-08-01 17:58:15.746 UTC] [V] OCMgr GetCurrentTargetPower current target:297.000000
[2026-08-01 17:58:15.746 UTC] [V] OCMgr CalcOutputControlRate rate:100, pow:297.000000, cap:297.000000, rate_out:297.000000
[2026-08-01 17:58:15.755 UTC] [V] OFSCtrl limit chk 400 < 800 < [1192->1192] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:15.755 UTC] [V] OFSCtrl angif value:1192 power_val_:20850.000000
[2026-08-01 17:58:15.757 UTC] [V] 485DevCtl <C1:01> device_type:Irr-Meter
[2026-08-01 17:58:15.757 UTC] [V] 485DevCtl <C1:01> device_type:Irr-Meter
[2026-08-01 17:58:15.757 UTC] [V] 485ChCtl <C1> fixed cycle Irr-Meter
[2026-08-01 17:58:15.757 UTC] [V] 485DevCtl <C1:01> Dev not PCS IsNeedToChangeOControlState
[2026-08-01 17:58:15.757 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :1
[2026-08-01 17:58:15.758 UTC] [V] 485ChCtl <C1> send request:Irr01
[2026-08-01 17:58:15.759 UTC] [D] 485AcReq <C1:01> PutOStream [1][080001040000000271cb]
[2026-08-01 17:58:15.775 UTC] [V] OCMgr IsPvocdCommunication 1
[2026-08-01 17:58:15.778 UTC] [V] OCMgr IsPvocdScheduleError 0
[2026-08-01 17:58:15.781 UTC] [V] OCMgr UpdateActiveMode mode:OFS conditions:output rate 100.
[2026-08-01 17:58:15.783 UTC] [V] LgMgr change mode OFS -> OFS
[2026-08-01 17:58:15.838 UTC] [V] Res no response condition. set normal condition.
[2026-08-01 17:58:15.839 UTC] [D] 485DevCtl <C2:03> RcvDat status[2] len[51] [03042e000000000000000000000000ffffffffffffffff03e8ffffffff00000000ffffffffffffffffffffffffffffffffa067]
[2026-08-01 17:58:15.839 UTC] [D] 485DevCtl <C2:03> ResCnd OperationId [9] IsNormal[1] 
[2026-08-01 17:58:15.840 UTC] [V] 485DevCtl <C2:03> [04][101100][0.000000][1][V]
[2026-08-01 17:58:15.840 UTC] [V] SummDat SetVrmValue dev_id:9 val:0.000000 sc:3
[2026-08-01 17:58:15.840 UTC] [V] OCMgr SetMeterValue PhId:0203, branchNo:04, valueId:101100, value:0.000000, scaleFactor:1, devId:9
[2026-08-01 17:58:15.841 UTC] [V] 485DevCtl <C2:03> [04][101101][0.000000][1][A]
[2026-08-01 17:58:15.841 UTC] [V] SummDat SetVrmValue dev_id:9 val:0.000000 sc:3
[2026-08-01 17:58:15.841 UTC] [V] OCMgr SetMeterValue PhId:0203, branchNo:04, valueId:101101, value:0.000000, scaleFactor:1, devId:9
[2026-08-01 17:58:15.855 UTC] [V] OFSCtrl limit chk 400 < 800 < [1192->1192] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:15.855 UTC] [V] OFSCtrl angif value:1192 power_val_:20850.000000
[2026-08-01 17:58:15.841 UTC] [V] 485DevCtl <C2:03> [05][101100][0.000000][1][V]
[2026-08-01 17:58:15.860 UTC] [V] SummDat SetVrmValue dev_id:9 val:0.000000 sc:3
[2026-08-01 17:58:15.861 UTC] [V] OCMgr SetMeterValue PhId:0203, branchNo:05, valueId:101100, value:0.000000, scaleFactor:1, devId:9
[2026-08-01 17:58:15.861 UTC] [V] 485DevCtl <C2:03> [05][101101][0.000000][1][A]
[2026-08-01 17:58:15.861 UTC] [V] SummDat SetVrmValue dev_id:9 val:0.000000 sc:3
[2026-08-01 17:58:15.861 UTC] [V] OCMgr SetMeterValue PhId:0203, branchNo:05, valueId:101101, value:0.000000, scaleFactor:1, devId:9
[2026-08-01 17:58:15.862 UTC] [V] 485DevCtl <C2:03> [06][101100][0.000000][1][V]
[2026-08-01 17:58:15.871 UTC] [V] SummDat SetVrmValue dev_id:9 val:0.000000 sc:3
[2026-08-01 17:58:15.876 UTC] [V] OCMgr SetMeterValue PhId:0203, branchNo:06, valueId:101100, value:0.000000, scaleFactor:1, devId:9
[2026-08-01 17:58:15.876 UTC] [V] 485DevCtl <C2:03> [06][101101][0.000000][1][A]
[2026-08-01 17:58:15.884 UTC] [V] 485DevCtl <C3:01> AnalyzeResponseData proc restart cnt:17975 UPRstat:0
[2026-08-01 17:58:15.886 UTC] [I] Wdog command:/usr/bin/touch "/mnt/system/check/pvsl"
[2026-08-01 17:58:15.876 UTC] [V] SummDat SetVrmValue dev_id:9 val:0.000000 sc:3
[2026-08-01 17:58:15.912 UTC] [V] OCMgr SetMeterValue PhId:0203, branchNo:06, valueId:101101, value:0.000000, scaleFactor:1, devId:9
[2026-08-01 17:58:15.908 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:58:15.915 UTC] [D] 485DevCtl <C3:01> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:58:15.916 UTC] [D] 485DevCtl <C3:01> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:58:15.926 UTC] [V] 485DevCtl <C2:03> device_type:PV-PCS
[2026-08-01 17:58:15.922 UTC] [V] 485DevCtl <C3:01> device_type:Battery
[2026-08-01 17:58:15.943 UTC] [V] 485ChCtl <C2> set rt:0
[2026-08-01 17:58:15.937 UTC] [V] 485DevCtl <C3:02> AnalyzeResponseData proc restart cnt:17975 UPRstat:0
[2026-08-01 17:58:15.955 UTC] [V] OFSCtrl limit chk 400 < 800 < [1192->1192] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:15.955 UTC] [V] OFSCtrl angif value:1192 power_val_:20850.000000
[2026-08-01 17:58:15.965 UTC] [V] 485ChCtl <C2> StartDeviceCommunicationForOutputFluctuationSuppressionControlBroadcast 4 cnt:179702, monitor_cnt:65, bc_elapsed:179702, min:10, max:40
[2026-08-01 17:58:15.965 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :1
[2026-08-01 17:58:15.966 UTC] [V] 485ChCtl <C2> send request:Sungrow08
[2026-08-01 17:58:15.966 UTC] [D] 485AcReq <C2:04> PutOStream [1][08000404138a0024d52a]
[2026-08-01 17:58:15.974 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:58:15.979 UTC] [D] 485DevCtl <C3:02> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:58:15.979 UTC] [D] 485DevCtl <C3:02> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:58:15.980 UTC] [V] 485DevCtl <C3:02> device_type:Battery
[2026-08-01 17:58:15.980 UTC] [V] 485DevCtl <C3:03> AnalyzeResponseData proc restart cnt:17975 UPRstat:0
[2026-08-01 17:58:15.981 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:58:16.012 UTC] [V] OFSCtrl [/var/local/solajithome/function/output_fluctuation_suppression/batt_data] write success.
[2026-08-01 17:58:16.019 UTC] [D] 485DevCtl <C3:03> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:58:16.019 UTC] [D] 485DevCtl <C3:03> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:58:16.020 UTC] [V] 485DevCtl <C3:03> device_type:Battery
[2026-08-01 17:58:16.020 UTC] [V] 485DevCtl <C3:04> AnalyzeResponseData proc restart cnt:17975 UPRstat:0
[2026-08-01 17:58:16.022 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:58:16.045 UTC] [D] 485DevCtl <C3:04> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:58:16.047 UTC] [D] 485DevCtl <C3:04> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:58:16.050 UTC] [V] 485DevCtl <C3:04> device_type:Battery
[2026-08-01 17:58:16.055 UTC] [V] OFSCtrl limit chk 400 < 800 < [1191->1191] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:16.055 UTC] [V] OFSCtrl angif value:1191 power_val_:20643.750000
[2026-08-01 17:58:16.055 UTC] [V] 485ChCtl <C3> set rt:0
[2026-08-01 17:58:16.079 UTC] [V] 485ChCtl <C3> StartDeviceCommunicationForOutputFluctuationSuppressionControlBroadcast 4 cnt:179703, monitor_cnt:60, bc_elapsed:179703, min:10, max:40
[2026-08-01 17:58:16.079 UTC] [V] 485DevCtl <C3:03> Dev not PCS IsNeedToChangeOControlState
[2026-08-01 17:58:16.079 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :1
[2026-08-01 17:58:16.080 UTC] [V] 485ChCtl <C3> send request:Sungrow11
[2026-08-01 17:58:16.081 UTC] [D] 485AcReq <C3:03> PutOStream [1][0c00000100000006010327470048]
[2026-08-01 17:58:16.097 UTC] [V] 485DevCtl <C1:01> AnalyzeResponseData proc restart cnt:17993 UPRstat:0
[2026-08-01 17:58:16.097 UTC] [V] Res no response condition. set normal condition.
[2026-08-01 17:58:16.098 UTC] [D] 485DevCtl <C1:01> RcvDat status[2] len[9] [010404000001fa7a57]
[2026-08-01 17:58:16.098 UTC] [D] 485DevCtl <C1:01> ResCnd OperationId [1] IsNormal[1] 
[2026-08-01 17:58:16.098 UTC] [V] OFSCtrl Rcv set flux_of_solar:0.000000
[2026-08-01 17:58:16.099 UTC] [V] 485DevCtl <C1:01> [01][401006][0.000000][1][W/m2]
[2026-08-01 17:58:16.099 UTC] [V] SummDat SetVrmValue dev_id:1 val:0.000000 sc:3
[2026-08-01 17:58:16.099 UTC] [V] OCMgr SetMeterValue PhId:0101, branchNo:01, valueId:401006, value:0.000000, scaleFactor:1, devId:1
[2026-08-01 17:58:16.099 UTC] [V] 485DevCtl <C1:01> [01][421005][256.000000][1][℃]
[2026-08-01 17:58:16.099 UTC] [V] SummDat SetVrmValue dev_id:1 val:25600.000000 sc:3
[2026-08-01 17:58:16.100 UTC] [V] OCMgr SetMeterValue PhId:0101, branchNo:01, valueId:421005, value:256.000000, scaleFactor:1, devId:1
[2026-08-01 17:58:16.100 UTC] [V] 485DevCtl <C1:01> device_type:Irr-Meter
[2026-08-01 17:58:16.100 UTC] [V] OFSCtrl Irr-Meter received.
[2026-08-01 17:58:16.100 UTC] [V] 485ChCtl <C1> set rt:0
[2026-08-01 17:58:16.115 UTC] [V] 485DevCtl <C1:01> device_type:Irr-Meter
[2026-08-01 17:58:16.155 UTC] [V] OFSCtrl limit chk 400 < 800 < [1191->1191] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:16.156 UTC] [V] OFSCtrl angif value:1191 power_val_:20643.750000
[2026-08-01 17:58:16.157 UTC] [V] 485DevCtl <C1:04> device_type:CO-Meter
[2026-08-01 17:58:16.157 UTC] [V] 485DevCtl <C1:04> device_type:CO-Meter
[2026-08-01 17:58:16.157 UTC] [V] 485ChCtl <C1> fixed cycle CO-Meter
[2026-08-01 17:58:16.157 UTC] [V] 485DevCtl <C1:04> Dev not PCS IsNeedToChangeOControlState
[2026-08-01 17:58:16.157 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :1
[2026-08-01 17:58:16.158 UTC] [V] 485ChCtl <C1> send request:omron05
[2026-08-01 17:58:16.163 UTC] [D] 485AcReq <C1:04> PutOStream [1][0800040300030014b590]
[2026-08-01 17:58:16.255 UTC] [V] OFSCtrl limit chk 400 < 800 < [1192->1192] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:16.255 UTC] [V] OFSCtrl angif value:1192 power_val_:20850.000000
[2026-08-01 17:58:16.313 UTC] [V] 485DevCtl <C3:03> AnalyzeResponseData proc restart cnt:17975 UPRstat:0
[2026-08-01 17:58:16.345 UTC] [D] 485DevCtl <C3:03> RcvDat status[0] len[153] [0001000000930103900001000200000000005500550000005500aa00a000fa000000fa0001000000000000000000000019ffffffffffffffffffffffffffffffffffffffffffff000100000000ffff0000ffffffffffffffffffffffffffffffffffff0fa0177003e800000e101388000a000a000000001950213400000000000000550055fffb0032ffff000000000000000000000000003f]
[2026-08-01 17:58:16.347 UTC] [D] 485DevCtl <C3:03> ResCnd OperationId [1] IsNormal[1]  ConditionType [lggrdev:Normal] Action[-1]
[2026-08-01 17:58:16.349 UTC] [V] 485DevCtl <C3:03> [01][753049][0.000000][0][]
[2026-08-01 17:58:16.355 UTC] [V] OFSCtrl limit chk 400 < 800 < [1192->1192] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:16.355 UTC] [V] OFSCtrl angif value:1192 power_val_:20850.000000
[2026-08-01 17:58:16.356 UTC] [V] SummDat SetVrmValue dev_id:15 val:0.000000 sc:0
[2026-08-01 17:58:16.362 UTC] [V] OCMgr SetMeterValue PhId:0303, branchNo:01, valueId:753049, value:0.000000, scaleFactor:0, devId:15
[2026-08-01 17:58:16.369 UTC] [V] Res no response condition. set normal condition.
[2026-08-01 17:58:16.373 UTC] [D] 485DevCtl <C2:04> RcvDat status[2] len[77] [0404480000c60800001250000000000000000000000000000000000000000000000000000000000000000000000000ffffffffffffffffffffffff00000000000000000000000000001400f643]
[2026-08-01 17:58:16.374 UTC] [D] 485DevCtl <C2:04> ResCnd OperationId [1] IsNormal[1] 
[2026-08-01 17:58:16.374 UTC] [V] 485DevCtl <C2:04> [01][115202][0.000000][1][kWh]
[2026-08-01 17:58:16.379 UTC] [V] SummDat SetVrmValue dev_id:10 val:0.000000 sc:1
[2026-08-01 17:58:16.386 UTC] [V] OCMgr SetMeterValue PhId:0204, branchNo:01, valueId:115202, value:0.000000, scaleFactor:1, devId:10
[2026-08-01 17:58:16.387 UTC] [V] 485DevCtl <C2:04> [01][113202][50696.000000][0][kWh]
[2026-08-01 17:58:16.380 UTC] [V] OFSCtrl Rcv set BATT(t-1)[0303]:0.126000 value:6300.000000/50000 BATT(t-1):0.110500 <- 22100.000000/200000
[2026-08-01 17:58:16.396 UTC] [V] 485DevCtl <C3:03> [01][753102][63.000000][1][kW]
[2026-08-01 17:58:16.396 UTC] [V] SummDat SetVrmValue dev_id:15 val:63.000000 sc:1
[2026-08-01 17:58:16.397 UTC] [V] OCMgr SetMeterValue PhId:0303, branchNo:01, valueId:753102, value:63.000000, scaleFactor:1, devId:15
[2026-08-01 17:58:16.400 UTC] [V] 485DevCtl <C3:03> device_type:Battery
[2026-08-01 17:58:16.401 UTC] [V] 485ChCtl <C3> set rt:0
[2026-08-01 17:58:16.399 UTC] [V] SummDat SetVrmValue dev_id:10 val:50696.000000 sc:0
[2026-08-01 17:58:16.408 UTC] [V] OCMgr SetMeterValue PhId:0204, branchNo:01, valueId:113202, value:50696.000000, scaleFactor:0, devId:10
[2026-08-01 17:58:16.409 UTC] [V] 485DevCtl <C2:04> [01][121005][0.000000][1][℃]
[2026-08-01 17:58:16.410 UTC] [V] SummDat SetVrmValue dev_id:10 val:0.000000 sc:3
[2026-08-01 17:58:16.417 UTC] [V] OCMgr SetMeterValue PhId:0204, branchNo:01, valueId:121005, value:0.000000, scaleFactor:1, devId:10
[2026-08-01 17:58:16.423 UTC] [V] 485DevCtl <C2:04> [01][101100][0.000000][1][V]
[2026-08-01 17:58:16.426 UTC] [V] SummDat SetVrmValue dev_id:10 val:0.000000 sc:3
[2026-08-01 17:58:16.427 UTC] [V] OCMgr SetMeterValue PhId:0204, branchNo:01, valueId:101100, value:0.000000, scaleFactor:1, devId:10
[2026-08-01 17:58:16.436 UTC] [V] 485DevCtl <C2:04> [01][101101][0.000000][1][A]
[2026-08-01 17:58:16.440 UTC] [V] SummDat SetVrmValue dev_id:10 val:0.000000 sc:3
[2026-08-01 17:58:16.442 UTC] [V] OCMgr SetMeterValue PhId:0204, branchNo:01, valueId:101101, value:0.000000, scaleFactor:1, devId:10
[2026-08-01 17:58:16.443 UTC] [V] 485DevCtl <C2:04> [02][101100][0.000000][1][V]
[2026-08-01 17:58:16.443 UTC] [V] SummDat SetVrmValue dev_id:10 val:0.000000 sc:3
[2026-08-01 17:58:16.443 UTC] [V] OCMgr SetMeterValue PhId:0204, branchNo:02, valueId:101100, value:0.000000, scaleFactor:1, devId:10
[2026-08-01 17:58:16.443 UTC] [V] 485DevCtl <C2:04> [02][101101][0.000000][1][A]
[2026-08-01 17:58:16.444 UTC] [V] SummDat SetVrmValue dev_id:10 val:0.000000 sc:3
[2026-08-01 17:58:16.444 UTC] [V] OCMgr SetMeterValue PhId:0204, branchNo:02, valueId:101101, value:0.000000, scaleFactor:1, devId:10
[2026-08-01 17:58:16.444 UTC] [V] 485DevCtl <C2:04> [03][101100][0.000000][1][V]
[2026-08-01 17:58:16.455 UTC] [V] OFSCtrl limit chk 400 < 800 < [1192->1192] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:16.455 UTC] [V] OFSCtrl angif value:1192 power_val_:20850.000000
[2026-08-01 17:58:16.455 UTC] [V] SummDat SetVrmValue dev_id:10 val:0.000000 sc:3
[2026-08-01 17:58:16.466 UTC] [V] OCMgr SetMeterValue PhId:0204, branchNo:03, valueId:101100, value:0.000000, scaleFactor:1, devId:10
[2026-08-01 17:58:16.469 UTC] [V] 485DevCtl <C2:04> [03][101101][0.000000][1][A]
[2026-08-01 17:58:16.469 UTC] [V] SummDat SetVrmValue dev_id:10 val:0.000000 sc:3
[2026-08-01 17:58:16.479 UTC] [V] 485ChCtl <C3> StartDeviceCommunicationForOutputFluctuationSuppressionControlBroadcast 4 cnt:179707, monitor_cnt:64, bc_elapsed:179707, min:10, max:40
[2026-08-01 17:58:16.479 UTC] [V] 485DevCtl <C3:04> Dev not PCS IsNeedToChangeOControlState
[2026-08-01 17:58:16.479 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :2
[2026-08-01 17:58:16.480 UTC] [V] 485ChCtl <C3> send request:Sungrow11
[2026-08-01 17:58:16.481 UTC] [D] 485AcReq <C3:04> PutOStream [2][0c0000010000000601042751005e]
[2026-08-01 17:58:16.487 UTC] [V] OCMgr SetMeterValue PhId:0204, branchNo:03, valueId:101101, value:0.000000, scaleFactor:1, devId:10
[2026-08-01 17:58:16.491 UTC] [V] 485DevCtl <C2:04> [01][101102][0.000000][0][W]
[2026-08-01 17:58:16.493 UTC] [V] SummDat SetVrmValue dev_id:10 val:0.000000 sc:3
[2026-08-01 17:58:16.494 UTC] [V] OCMgr SetMeterValue PhId:0204, branchNo:01, valueId:101102, value:0.000000, scaleFactor:0, devId:10
[2026-08-01 17:58:16.504 UTC] [V] 485DevCtl <C2:04> [01][111200][0.000000][1][V]
[2026-08-01 17:58:16.504 UTC] [V] SummDat SetVrmValue dev_id:10 val:0.000000 sc:3
[2026-08-01 17:58:16.512 UTC] [V] OCMgr SetMeterValue PhId:0204, branchNo:01, valueId:111200, value:0.000000, scaleFactor:1, devId:10
[2026-08-01 17:58:16.518 UTC] [V] 485DevCtl <C2:04> [02][111200][0.000000][1][V]
[2026-08-01 17:58:16.522 UTC] [V] SummDat SetVrmValue dev_id:10 val:0.000000 sc:3
[2026-08-01 17:58:16.527 UTC] [V] OCMgr SetMeterValue PhId:0204, branchNo:02, valueId:111200, value:0.000000, scaleFactor:1, devId:10
[2026-08-01 17:58:16.532 UTC] [V] 485DevCtl <C2:04> [03][111200][0.000000][1][V]
[2026-08-01 17:58:16.532 UTC] [V] SummDat SetVrmValue dev_id:10 val:0.000000 sc:3
[2026-08-01 17:58:16.532 UTC] [V] OCMgr SetMeterValue PhId:0204, branchNo:03, valueId:111200, value:0.000000, scaleFactor:1, devId:10
[2026-08-01 17:58:16.544 UTC] [V] 485DevCtl <C2:04> [01][111201][0.000000][1][A]
[2026-08-01 17:58:16.545 UTC] [V] SummDat SetVrmValue dev_id:10 val:0.000000 sc:3
[2026-08-01 17:58:16.545 UTC] [V] OCMgr SetMeterValue PhId:0204, branchNo:01, valueId:111201, value:0.000000, scaleFactor:1, devId:10
[2026-08-01 17:58:16.545 UTC] [V] 485DevCtl <C2:04> [02][111201][0.000000][1][A]
[2026-08-01 17:58:16.545 UTC] [V] SummDat SetVrmValue dev_id:10 val:0.000000 sc:3
[2026-08-01 17:58:16.546 UTC] [V] OCMgr SetMeterValue PhId:0204, branchNo:02, valueId:111201, value:0.000000, scaleFactor:1, devId:10
[2026-08-01 17:58:16.546 UTC] [V] 485DevCtl <C2:04> [03][111201][0.000000][1][A]
[2026-08-01 17:58:16.546 UTC] [V] SummDat SetVrmValue dev_id:10 val:0.000000 sc:3
[2026-08-01 17:58:16.546 UTC] [V] OCMgr SetMeterValue PhId:0204, branchNo:03, valueId:111201, value:0.000000, scaleFactor:1, devId:10
[2026-08-01 17:58:16.560 UTC] [V] 485DevCtl <C1:04> AnalyzeResponseData proc restart cnt:17993 UPRstat:0
[2026-08-01 17:58:16.560 UTC] [V] Res no response condition. set normal condition.
[2026-08-01 17:58:16.562 UTC] [D] 485DevCtl <C1:04> RcvDat status[2] len[45] [0403280000f2bc0000f9e10000e21000000064000002570003431100000859ffffbed4ffffff5a00233b03f00b]
[2026-08-01 17:58:16.562 UTC] [D] 485DevCtl <C1:04> ResCnd OperationId [1] IsNormal[1] 
[2026-08-01 17:58:16.572 UTC] [V] OFSCtrl limit chk 400 < 800 < [1192->1192] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:16.572 UTC] [V] OFSCtrl angif value:1192 power_val_:20850.000000
[2026-08-01 17:58:16.572 UTC] [V] OFSCtrl Control charge discharge proc start.
[2026-08-01 17:58:16.573 UTC] [V] OFSCtrl CHG 20 p_th(t):20779.050000 = p_th_old_:20808.750000 + lev_cd_:-0.300000 * (total_pcs_capacity_:297000.000000 * cof_spec_:2.000000 / 60 * (time_threshold_renew:10.000000 * 10)), min:-2062.500000, max:407900.000000
[2026-08-01 17:58:16.573 UTC] [V] OFSCtrl CHG 21 batt_w:21109.222079 = old:21149.432579 +  kp:0.550000 * e:-70.950000 + ki:0.000000 * sume:-13450.799856 + kd:0.040000 * (e:-70.950000 - e1:-41.250000)
[2026-08-01 17:58:16.573 UTC] [V] OFSCtrl CHG 21 battery threshold min:20000.000000 <= bat:21109.222079 <= max:196000.000000, adjust charge:0.000000, discharge:1000.000000
[2026-08-01 17:58:16.574 UTC] [V] OFSCtrl CHG 29 q:52.000000, mod(round):3.000000
[2026-08-01 17:58:16.574 UTC] [V] OFSCtrl discharge bat_w[0303]:6300.000000 += adjust:1000.000000
[2026-08-01 17:58:16.574 UTC] [D] OFSCtrl battery ctrl val:10.600000
[2026-08-01 17:58:16.575 UTC] [V] OFSCtrl Rcv set p_co:21370.000000, p_co_old:21610.000000
[2026-08-01 17:58:16.575 UTC] [V] 485DevCtl <C1:04> [01][601260][2137.000000][2][kW]
[2026-08-01 17:58:16.575 UTC] [V] SummDat SetVrmValue dev_id:4 val:21370.000000 sc:3
[2026-08-01 17:58:16.576 UTC] [V] OCMgr SetMeterValue PhId:0104, branchNo:01, valueId:601260, value:2137.000000, scaleFactor:2, devId:4
[2026-08-01 17:58:16.576 UTC] [V] 485DevCtl <C1:04> [01][603260][2308867.000000][1][kWh]
[2026-08-01 17:58:16.576 UTC] [V] SummDat SetVrmValue dev_id:4 val:2308867.000000 sc:1
[2026-08-01 17:58:16.577 UTC] [V] OCMgr SetMeterValue PhId:0104, branchNo:01, valueId:603260, value:2308867.000000, scaleFactor:1, devId:4
[2026-08-01 17:58:16.577 UTC] [V] 485DevCtl <C1:04> device_type:CO-Meter
[2026-08-01 17:58:16.578 UTC] [V] 485ChCtl <C3> battery limit on [53.000000,53.000000,63.000000,52.000000,] request.
[2026-08-01 17:58:16.579 UTC] [V] OFSCtrl Control charge discharge proc:01->02->BATT_CHK->03->04->05->06->10->12->13->15->16->18->19->20->21->22->23->24->25->27->23->24->25->27->23->24->25->27->23->24->25->27->28->29->30->31->32->30->31->32->30->31->32->30->31->32->33->34
[2026-08-01 17:58:16.579 UTC] [V] 485DevCtl <C2:04> [01][111202][0.000000][0][W]
[2026-08-01 17:58:16.580 UTC] [V] OFSCtrl km50 received.
[2026-08-01 17:58:16.581 UTC] [V] SummDat SetVrmValue dev_id:10 val:0.000000 sc:3
[2026-08-01 17:58:16.584 UTC] [V] OCMgr SetMeterValue PhId:0204, branchNo:01, valueId:111202, value:0.000000, scaleFactor:0, devId:10
[2026-08-01 17:58:16.585 UTC] [V] 485DevCtl <C2:04> [01][111203][0.000000][0][var]
[2026-08-01 17:58:16.585 UTC] [V] SummDat SetVrmValue dev_id:10 val:0.000000 sc:3
[2026-08-01 17:58:16.586 UTC] [V] OFSCtrl omron05_local_date :2026/08/02 ? 2026/08/02
[2026-08-01 17:58:16.586 UTC] [V] OFSCtrl omron05_local_time :2026/08/02 02 ? 2026/08/02 02
[2026-08-01 17:58:16.586 UTC] [V] OFSCtrl out of control time.
[2026-08-01 17:58:16.586 UTC] [V] OFSCtrl Control pv-pcs proc start.
[2026-08-01 17:58:16.587 UTC] [V] OFSCtrl NOD_month:-445.000000 = (NOD_month:13 - ((nod_max_/30):23.333333 * (cnt-1):12) * (30/cnt):1.666667 
[2026-08-01 17:58:16.587 UTC] [V] OFSCtrl PCS ratio_month:113.496241 = -k_inhibition_ratio_month:-0.097744 * NOD_month:-445.000000 + inhibition_ratio_max:70
[2026-08-01 17:58:16.588 UTC] [V] OCMgr SetMeterValue PhId:0204, branchNo:01, valueId:111203, value:0.000000, scaleFactor:0, devId:10
[2026-08-01 17:58:16.589 UTC] [V] OFSCtrl PCS 05 inhibition_ratio:70.000000 = max(ratio_min:5, min(ratio:70, ratio_hour:70.000000, ratio_day:70.000000, ratio_month:113.496241))
[2026-08-01 17:58:16.594 UTC] [D] OFSCtrl pv-pcs ctrl val:0.000000 old:0.000000
[2026-08-01 17:58:16.595 UTC] [V] 485DevCtl <C2:04> [01][121007][0.000000][3][]
[2026-08-01 17:58:16.598 UTC] [V] OCHisDB set rate:0 t_rate:0 cnt:36
[2026-08-01 17:58:16.601 UTC] [V] 485ChCtl <C2> pv-pcs limit on [0.000000] request.
[2026-08-01 17:58:16.601 UTC] [V] OFSCtrl Control pv-pcs proc:BATT_CHK->01->02->03->04->05->06->07->09->09->10->11->12
[2026-08-01 17:58:16.601 UTC] [V] OFSCtrl Nod calc proc start.
[2026-08-01 17:58:16.601 UTC] [V] OFSCtrl ProcNodCountCalculation culc nod skip stop:0, pause:0, ctl_time:0
[2026-08-01 17:58:16.602 UTC] [V] OFSCtrl update p_co_old:21370.000000
[2026-08-01 17:58:16.602 UTC] [V] OFSCtrl Nod calc proc:
[2026-08-01 17:58:16.599 UTC] [V] SummDat SetVrmValue dev_id:10 val:0.000000 sc:3
[2026-08-01 17:58:16.602 UTC] [V] OCMgr SetMeterValue PhId:0204, branchNo:01, valueId:121007, value:0.000000, scaleFactor:3, devId:10
[2026-08-01 17:58:16.603 UTC] [V] 485DevCtl <C2:04> [01][131006][0.000000][1][Hz]
[2026-08-01 17:58:16.603 UTC] [V] SummDat SetVrmValue dev_id:10 val:0.000000 sc:3
[2026-08-01 17:58:16.603 UTC] [V] OCMgr SetMeterValue PhId:0204, branchNo:01, valueId:131006, value:0.000000, scaleFactor:1, devId:10
[2026-08-01 17:58:16.603 UTC] [V] 485DevCtl <C2:04> [01][114202][50696.000000][0][kWh]
[2026-08-01 17:58:16.604 UTC] [V] SummDat SetVrmValue dev_id:10 val:50696000.000000 sc:3
[2026-08-01 17:58:16.604 UTC] [V] OCMgr SetMeterValue PhId:0204, branchNo:01, valueId:114202, value:50696.000000, scaleFactor:0, devId:10
[2026-08-01 17:58:16.614 UTC] [V] 485ChCtl <C1> set rt:0
[2026-08-01 17:58:16.616 UTC] [V] 485DevCtl <C1:04> device_type:CO-Meter
[2026-08-01 17:58:16.604 UTC] [V] 485DevCtl <C2:04> device_type:PV-PCS
[2026-08-01 17:58:16.633 UTC] [V] 485DevCtl <C2:04> set2 StatusCode[010100] DeviceName[] DeviceNumber[]
[2026-08-01 17:58:16.636 UTC] [V] 485ChCtl <C2> set rt:0
[2026-08-01 17:58:16.655 UTC] [V] OFSCtrl limit chk 400 < 800 < [1192->1192] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:16.655 UTC] [V] OFSCtrl angif value:1192 power_val_:20850.000000
[2026-08-01 17:58:16.664 UTC] [V] 485DevCtl <C3:04> AnalyzeResponseData proc restart cnt:17976 UPRstat:0
[2026-08-01 17:58:16.664 UTC] [V] 485ChCtl <C2> pv-pcs send request.
[2026-08-01 17:58:16.665 UTC] [D] VarInf update ofs_rate:0.000000
[2026-08-01 17:58:16.665 UTC] [V] VarInf LimitSet rt[2] val[170] key[ValueOn]
[2026-08-01 17:58:16.665 UTC] [D] VarInf output_mode:8
[2026-08-01 17:58:16.665 UTC] [D] VarInf update ofs_rate:0.000000
[2026-08-01 17:58:16.665 UTC] [D] VarInf Limit setRate[0.000000] rate[0.000000] value100[1000.000000] value0[0.000000]
[2026-08-01 17:58:16.665 UTC] [V] 485DevCtl <C2:01> ChangeOutputRateToDevice rate:0.000000 set_rate1
[2026-08-01 17:58:16.665 UTC] [D] VarInf Limit rt[2] int_set_rate[1] server_rate[0.000000] rated_output[100.000000] solar_battery_power[100.000000]
[2026-08-01 17:58:16.668 UTC] [D] 485AcReq <C2:01> PutOStreamForBc [3][0d000010138e00020400aa0001466f]
[2026-08-01 17:58:16.706 UTC] [D] 485DevCtl <C3:04> RcvDat status[0] len[197] [0001000000bf0104bc0000ffffffffffff006700000000001000000000000000000000000000000000000000ae0032009a0000000100010001ffffffffffffffffffffffffffffffffffffffff000100000001000000010000ffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffff000101f4000000340000fffffffffc19448900003e3200000000000000ae0000]
[2026-08-01 17:58:16.709 UTC] [D] 485DevCtl <C3:04> ResCnd OperationId [2] IsNormal[1]  ConditionType [lggrdev:Normal] Action[-1]
[2026-08-01 17:58:16.719 UTC] [V] 485DevCtl <C3:04> [02][753049][0.000000][0][]
[2026-08-01 17:58:16.719 UTC] [V] SummDat SetVrmValue dev_id:16 val:0.000000 sc:0
[2026-08-01 17:58:16.720 UTC] [V] OCMgr SetMeterValue PhId:0304, branchNo:02, valueId:753049, value:0.000000, scaleFactor:0, devId:16
[2026-08-01 17:58:16.720 UTC] [V] 485DevCtl <C3:04> [01][753040][16.000000][0][]
[2026-08-01 17:58:16.720 UTC] [V] SummDat SetVrmValue dev_id:16 val:16.000000 sc:0
[2026-08-01 17:58:16.727 UTC] [V] OCMgr SetMeterValue PhId:0304, branchNo:01, valueId:753040, value:16.000000, scaleFactor:0, devId:16
[2026-08-01 17:58:16.730 UTC] [V] 485DevCtl <C3:04> [01][753053][0.000000][0][]
[2026-08-01 17:58:16.737 UTC] [V] SummDat SetVrmValue dev_id:16 val:0.000000 sc:0
[2026-08-01 17:58:16.752 UTC] [V] OCMgr SetMeterValue PhId:0304, branchNo:01, valueId:753053, value:0.000000, scaleFactor:0, devId:16
[2026-08-01 17:58:16.754 UTC] [V] 485DevCtl <C3:04> [02][753053][0.000000][0][]
[2026-08-01 17:58:16.755 UTC] [V] OFSCtrl limit chk 400 < 800 < [1192->1192] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:16.755 UTC] [V] OFSCtrl angif value:1192 power_val_:20850.000000
[2026-08-01 17:58:16.754 UTC] [V] SummDat SetVrmValue dev_id:16 val:0.000000 sc:0
[2026-08-01 17:58:16.764 UTC] [V] OCMgr SetMeterValue PhId:0304, branchNo:02, valueId:753053, value:0.000000, scaleFactor:0, devId:16
[2026-08-01 17:58:16.773 UTC] [V] 485DevCtl <C3:04> [03][753053][0.000000][0][]
[2026-08-01 17:58:16.775 UTC] [V] SummDat SetVrmValue dev_id:16 val:0.000000 sc:0
[2026-08-01 17:58:16.780 UTC] [V] OCMgr SetMeterValue PhId:0304, branchNo:03, valueId:753053, value:0.000000, scaleFactor:0, devId:16
[2026-08-01 17:58:16.780 UTC] [V] 485DevCtl <C3:04> [04][753053][0.000000][0][]
[2026-08-01 17:58:16.780 UTC] [V] SummDat SetVrmValue dev_id:16 val:0.000000 sc:0
[2026-08-01 17:58:16.781 UTC] [V] OCMgr SetMeterValue PhId:0304, branchNo:04, valueId:753053, value:0.000000, scaleFactor:0, devId:16
[2026-08-01 17:58:16.781 UTC] [V] 485DevCtl <C3:04> [01][716202][500.000000][1][kW]
[2026-08-01 17:58:16.788 UTC] [V] SummDat SetVrmValue dev_id:16 val:50.000000 sc:0
[2026-08-01 17:58:16.803 UTC] [V] OCMgr SetMeterValue PhId:0304, branchNo:01, valueId:716202, value:500.000000, scaleFactor:1, devId:16
[2026-08-01 17:58:16.804 UTC] [V] 485DevCtl <C3:04> [01][711102][52.000000][1][kW]
[2026-08-01 17:58:16.804 UTC] [V] SummDat SetVrmValue dev_id:16 val:5200.000000 sc:3
[2026-08-01 17:58:16.810 UTC] [V] OCMgr SetMeterValue PhId:0304, branchNo:01, valueId:711102, value:52.000000, scaleFactor:1, devId:16
[2026-08-01 17:58:16.817 UTC] [V] 485DevCtl <C3:04> [01][703102][17545.000000][0][kWh]
[2026-08-01 17:58:16.823 UTC] [V] SummDat SetVrmValue dev_id:16 val:17545.000000 sc:0
[2026-08-01 17:58:16.823 UTC] [V] OCMgr SetMeterValue PhId:0304, branchNo:01, valueId:703102, value:17545.000000, scaleFactor:0, devId:16
[2026-08-01 17:58:16.823 UTC] [V] 485DevCtl <C3:04> [01][713102][15922.000000][0][kWh]
[2026-08-01 17:58:16.824 UTC] [V] SummDat SetVrmValue dev_id:16 val:15922.000000 sc:0
[2026-08-01 17:58:16.824 UTC] [V] OCMgr SetMeterValue PhId:0304, branchNo:01, valueId:713102, value:15922.000000, scaleFactor:0, devId:16
[2026-08-01 17:58:16.836 UTC] [V] 485DevCtl <C3:04> device_type:Battery
[2026-08-01 17:58:16.848 UTC] [V] 485ChCtl <C3> set rt:0
[2026-08-01 17:58:16.851 UTC] [D] 485ChCtl <C3> monitoring dev All Send
[2026-08-01 17:58:16.855 UTC] [V] OFSCtrl limit chk 400 < 800 < [1192->1192] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:16.856 UTC] [V] OFSCtrl angif value:1192 power_val_:20850.000000
[2026-08-01 17:58:16.879 UTC] [V] 485ChCtl <C3> battery send request.1
[2026-08-01 17:58:16.880 UTC] [D] VarInf Limit_Bat rt[2]set val[53] set rate[10.600000] value100[500] value-100[-500]
[2026-08-01 17:58:16.881 UTC] [D] VarInf Limit_Bat rt[2]set val[53] set rate[10.600000] value100[500] value-100[-500]
[2026-08-01 17:58:16.882 UTC] [D] VarInf Limit_Bat rt[2]set val[63] set rate[12.600000] value100[500] value-100[-500]
[2026-08-01 17:58:16.891 UTC] [D] VarInf Limit_Bat rt[2]set val[52] set rate[10.400000] value100[500] value-100[-500]
[2026-08-01 17:58:16.904 UTC] [D] 485AcReq <C3:01> PutOStream [6][0f000001000000090110278e0001020035]
[2026-08-01 17:58:16.906 UTC] [D] 485AcReq <C3:02> PutOStream [6][0f000001000000090110278e0001020035]
[2026-08-01 17:58:16.906 UTC] [D] 485AcReq <C3:03> PutOStream [6][0f000001000000090110278e000102003f]
[2026-08-01 17:58:16.907 UTC] [D] 485AcReq <C3:04> PutOStream [6][0f000001000000090110278e0001020034]
[2026-08-01 17:58:16.955 UTC] [V] OFSCtrl limit chk 400 < 800 < [1192->1192] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:16.955 UTC] [V] OFSCtrl angif value:1192 power_val_:20850.000000
[2026-08-01 17:58:16.960 UTC] [V] 485ChCtl <C2> set rt:0
[2026-08-01 17:58:16.964 UTC] [V] 485ChCtl <C2> StartDeviceCommunicationForOutputFluctuationSuppressionControlBroadcast 4 cnt:179712, monitor_cnt:75, bc_elapsed:179712, min:10, max:40
[2026-08-01 17:58:16.964 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :4
[2026-08-01 17:58:16.965 UTC] [V] 485ChCtl <C2> send request:Sungrow08
[2026-08-01 17:58:16.966 UTC] [D] 485AcReq <C2:05> PutOStream [4][0800050413b4000174ec]
[2026-08-01 17:58:17.012 UTC] [V] OFSCtrl [/var/local/solajithome/function/output_fluctuation_suppression/batt_data] write success.
[2026-08-01 17:58:17.055 UTC] [V] OFSCtrl limit chk 400 < 800 < [1192->1192] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:17.055 UTC] [V] OFSCtrl angif value:1192 power_val_:20850.000000
[2026-08-01 17:58:17.094 UTC] [V] 485DevCtl <C3:01> AnalyzeResponseData proc restart cnt:17976 UPRstat:0
[2026-08-01 17:58:17.096 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:58:17.097 UTC] [D] 485DevCtl <C3:01> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:58:17.097 UTC] [D] 485DevCtl <C3:01> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:58:17.097 UTC] [V] 485DevCtl <C3:01> device_type:Battery
[2026-08-01 17:58:17.097 UTC] [V] 485DevCtl <C3:02> AnalyzeResponseData proc restart cnt:17976 UPRstat:0
[2026-08-01 17:58:17.125 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:58:17.138 UTC] [D] 485DevCtl <C3:02> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:58:17.139 UTC] [D] 485DevCtl <C3:02> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:58:17.139 UTC] [V] 485DevCtl <C3:02> device_type:Battery
[2026-08-01 17:58:17.152 UTC] [V] 485DevCtl <C3:03> AnalyzeResponseData proc restart cnt:17976 UPRstat:0
[2026-08-01 17:58:17.155 UTC] [V] OFSCtrl limit chk 400 < 800 < [1192->1192] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:17.155 UTC] [V] OFSCtrl angif value:1192 power_val_:20850.000000
[2026-08-01 17:58:17.185 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:58:17.204 UTC] [D] 485DevCtl <C3:03> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:58:17.205 UTC] [D] 485DevCtl <C3:03> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:58:17.205 UTC] [V] 485DevCtl <C3:03> device_type:Battery
[2026-08-01 17:58:17.220 UTC] [V] 485DevCtl <C3:04> AnalyzeResponseData proc restart cnt:17976 UPRstat:0
[2026-08-01 17:58:17.237 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:58:17.253 UTC] [D] 485DevCtl <C3:04> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:58:17.253 UTC] [D] 485DevCtl <C3:04> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:58:17.253 UTC] [V] 485DevCtl <C3:04> device_type:Battery
[2026-08-01 17:58:17.254 UTC] [V] 485ChCtl <C3> set rt:0
[2026-08-01 17:58:17.255 UTC] [V] OFSCtrl limit chk 400 < 800 < [1192->1192] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:17.255 UTC] [V] OFSCtrl angif value:1192 power_val_:20850.000000
[2026-08-01 17:58:17.298 UTC] [D] 485DevCtl <C2:05> RcvDat status[2] len[7] [050402000048f0]
[2026-08-01 17:58:17.299 UTC] [D] 485DevCtl <C2:05> ResCnd OperationId [4] IsNormal[0]  ConditionType [lggrdev:Error] Action[-1]
[2026-08-01 17:58:17.299 UTC] [V] 485DevCtl <C2:05> device_type:PV-PCS
[2026-08-01 17:58:17.300 UTC] [V] 485ChCtl <C2> set rt:0
[2026-08-01 17:58:17.356 UTC] [V] OFSCtrl limit chk 400 < 800 < [1192->1192] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:17.356 UTC] [V] OFSCtrl angif value:1192 power_val_:20850.000000
[2026-08-01 17:58:17.364 UTC] [V] 485ChCtl <C2> StartDeviceCommunicationForOutputFluctuationSuppressionControlBroadcast 4 cnt:179716, monitor_cnt:79, bc_elapsed:179716, min:10, max:40
[2026-08-01 17:58:17.364 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :9
[2026-08-01 17:58:17.365 UTC] [V] 485ChCtl <C2> send request:Sungrow08
[2026-08-01 17:58:17.366 UTC] [D] 485AcReq <C2:06> PutOStream [9][0800060413fa00179506]
[2026-08-01 17:58:17.455 UTC] [V] OFSCtrl limit chk 400 < 800 < [1192->1192] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:17.456 UTC] [V] OFSCtrl angif value:1192 power_val_:20850.000000
[2026-08-01 17:58:17.555 UTC] [V] OFSCtrl limit chk 400 < 800 < [1192->1192] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:17.555 UTC] [V] OFSCtrl angif value:1192 power_val_:20850.000000
[2026-08-01 17:58:17.555 UTC] [V] OFSCtrl Control charge discharge proc start.
[2026-08-01 17:58:17.556 UTC] [V] OFSCtrl CHG 20 p_th(t):20749.350000 = p_th_old_:20779.050000 + lev_cd_:-0.300000 * (total_pcs_capacity_:297000.000000 * cof_spec_:2.000000 / 60 * (time_threshold_renew:10.000000 * 10)), min:-2062.500000, max:407900.000000
[2026-08-01 17:58:17.556 UTC] [V] OFSCtrl CHG 21 batt_w:21052.676579 = old:21109.222079 +  kp:0.550000 * e:-100.650000 + ki:0.000000 * sume:-13551.449856 + kd:0.040000 * (e:-100.650000 - e1:-70.950000)
[2026-08-01 17:58:17.557 UTC] [V] OFSCtrl CHG 21 battery threshold min:20000.000000 <= bat:21052.676579 <= max:196000.000000, adjust charge:0.000000, discharge:1000.000000
[2026-08-01 17:58:17.557 UTC] [V] OFSCtrl CHG 29 q:52.000000, mod(round):3.000000
[2026-08-01 17:58:17.557 UTC] [V] OFSCtrl discharge bat_w[0303]:6300.000000 += adjust:1000.000000
[2026-08-01 17:58:17.557 UTC] [D] OFSCtrl battery ctrl val:10.500000
[2026-08-01 17:58:17.558 UTC] [V] 485ChCtl <C3> battery limit on [53.000000,53.000000,63.000000,52.000000,] request.
[2026-08-01 17:58:17.558 UTC] [V] OFSCtrl Control charge discharge proc:01->02->BATT_CHK->03->04->05->06->10->12->13->15->16->18->19->20->21->22->23->24->25->27->23->24->25->27->23->24->25->27->23->24->25->27->28->29->30->31->32->30->31->32->30->31->32->30->31->32->33->34
[2026-08-01 17:58:17.579 UTC] [V] 485ChCtl <C3> battery send request.1
[2026-08-01 17:58:17.579 UTC] [D] VarInf Limit_Bat rt[2]set val[53] set rate[10.600000] value100[500] value-100[-500]
[2026-08-01 17:58:17.580 UTC] [D] VarInf Limit_Bat rt[2]set val[53] set rate[10.600000] value100[500] value-100[-500]
[2026-08-01 17:58:17.581 UTC] [D] VarInf Limit_Bat rt[2]set val[63] set rate[12.600000] value100[500] value-100[-500]
[2026-08-01 17:58:17.586 UTC] [D] VarInf Limit_Bat rt[2]set val[52] set rate[10.400000] value100[500] value-100[-500]
[2026-08-01 17:58:17.613 UTC] [D] 485AcReq <C3:01> PutOStream [6][0f000001000000090110278e0001020035]
[2026-08-01 17:58:17.613 UTC] [D] 485AcReq <C3:02> PutOStream [6][0f000001000000090110278e0001020035]
[2026-08-01 17:58:17.614 UTC] [D] 485AcReq <C3:03> PutOStream [6][0f000001000000090110278e000102003f]
[2026-08-01 17:58:17.615 UTC] [D] 485AcReq <C3:04> PutOStream [6][0f000001000000090110278e0001020034]
[2026-08-01 17:58:17.655 UTC] [V] OFSCtrl limit chk 400 < 800 < [1192->1192] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:17.656 UTC] [V] OFSCtrl angif value:1192 power_val_:20850.000000
[2026-08-01 17:58:17.742 UTC] [V] Res no response condition. set normal condition.
[2026-08-01 17:58:17.744 UTC] [D] 485DevCtl <C2:06> RcvDat status[2] len[51] [06042e000000000000000000000000ffffffffffffffff03e8ffffffff08240000ffffffffffffffffffffffffffffffffa240]
[2026-08-01 17:58:17.744 UTC] [D] 485DevCtl <C2:06> ResCnd OperationId [9] IsNormal[1] 
[2026-08-01 17:58:17.745 UTC] [V] 485DevCtl <C2:06> [04][101100][0.000000][1][V]
[2026-08-01 17:58:17.746 UTC] [V] SummDat SetVrmValue dev_id:12 val:0.000000 sc:3
[2026-08-01 17:58:17.753 UTC] [V] OCMgr SetMeterValue PhId:0206, branchNo:04, valueId:101100, value:0.000000, scaleFactor:1, devId:12
[2026-08-01 17:58:17.755 UTC] [V] OFSCtrl limit chk 400 < 800 < [1192->1192] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:17.755 UTC] [V] OFSCtrl angif value:1192 power_val_:20850.000000
[2026-08-01 17:58:17.759 UTC] [V] 485DevCtl <C2:06> [04][101101][0.000000][1][A]
[2026-08-01 17:58:17.761 UTC] [V] SummDat SetVrmValue dev_id:12 val:0.000000 sc:3
[2026-08-01 17:58:17.765 UTC] [V] OCMgr SetMeterValue PhId:0206, branchNo:04, valueId:101101, value:0.000000, scaleFactor:1, devId:12
[2026-08-01 17:58:17.768 UTC] [V] 485DevCtl <C2:06> [05][101100][0.000000][1][V]
[2026-08-01 17:58:17.769 UTC] [V] SummDat SetVrmValue dev_id:12 val:0.000000 sc:3
[2026-08-01 17:58:17.769 UTC] [V] OCMgr SetMeterValue PhId:0206, branchNo:05, valueId:101100, value:0.000000, scaleFactor:1, devId:12
[2026-08-01 17:58:17.774 UTC] [V] 485DevCtl <C2:06> [05][101101][0.000000][1][A]
[2026-08-01 17:58:17.775 UTC] [V] SummDat SetVrmValue dev_id:12 val:0.000000 sc:3
[2026-08-01 17:58:17.777 UTC] [V] OCMgr SetMeterValue PhId:0206, branchNo:05, valueId:101101, value:0.000000, scaleFactor:1, devId:12
[2026-08-01 17:58:17.781 UTC] [V] 485DevCtl <C2:06> [06][101100][0.000000][1][V]
[2026-08-01 17:58:17.784 UTC] [V] 485DevCtl <C3:01> AnalyzeResponseData proc restart cnt:17977 UPRstat:0
[2026-08-01 17:58:17.786 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:58:17.787 UTC] [D] 485DevCtl <C3:01> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:58:17.787 UTC] [D] 485DevCtl <C3:01> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:58:17.787 UTC] [V] 485DevCtl <C3:01> device_type:Battery
[2026-08-01 17:58:17.787 UTC] [V] 485DevCtl <C3:02> AnalyzeResponseData proc restart cnt:17977 UPRstat:0
[2026-08-01 17:58:17.790 UTC] [V] SummDat SetVrmValue dev_id:12 val:0.000000 sc:3
[2026-08-01 17:58:17.794 UTC] [V] OCMgr SetMeterValue PhId:0206, branchNo:06, valueId:101100, value:0.000000, scaleFactor:1, devId:12
[2026-08-01 17:58:17.802 UTC] [V] 485DevCtl <C2:06> [06][101101][0.000000][1][A]
[2026-08-01 17:58:17.805 UTC] [V] SummDat SetVrmValue dev_id:12 val:0.000000 sc:3
[2026-08-01 17:58:17.807 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:58:17.808 UTC] [D] 485DevCtl <C3:02> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:58:17.808 UTC] [D] 485DevCtl <C3:02> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:58:17.808 UTC] [V] 485DevCtl <C3:02> device_type:Battery
[2026-08-01 17:58:17.808 UTC] [V] 485DevCtl <C3:03> AnalyzeResponseData proc restart cnt:17977 UPRstat:0
[2026-08-01 17:58:17.810 UTC] [V] OCMgr SetMeterValue PhId:0206, branchNo:06, valueId:101101, value:0.000000, scaleFactor:1, devId:12
[2026-08-01 17:58:17.819 UTC] [V] 485DevCtl <C2:06> device_type:PV-PCS
[2026-08-01 17:58:17.828 UTC] [V] 485ChCtl <C2> set rt:0
[2026-08-01 17:58:17.828 UTC] [D] 485ChCtl <C2> monitoring dev All Send
[2026-08-01 17:58:17.830 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:58:17.834 UTC] [D] 485DevCtl <C3:03> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:58:17.835 UTC] [D] 485DevCtl <C3:03> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:58:17.836 UTC] [V] 485DevCtl <C3:03> device_type:Battery
[2026-08-01 17:58:17.841 UTC] [V] 485DevCtl <C3:04> AnalyzeResponseData proc restart cnt:17977 UPRstat:0
[2026-08-01 17:58:17.855 UTC] [V] OFSCtrl limit chk 400 < 800 < [1192->1192] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:17.855 UTC] [V] OFSCtrl angif value:1192 power_val_:20850.000000
[2026-08-01 17:58:17.861 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:58:17.868 UTC] [D] 485DevCtl <C3:04> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:58:17.869 UTC] [D] 485DevCtl <C3:04> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:58:17.869 UTC] [V] 485DevCtl <C3:04> device_type:Battery
[2026-08-01 17:58:17.869 UTC] [V] 485ChCtl <C3> set rt:0
[2026-08-01 17:58:17.955 UTC] [V] OFSCtrl limit chk 400 < 800 < [1192->1192] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:17.955 UTC] [V] OFSCtrl angif value:1192 power_val_:20850.000000
[2026-08-01 17:58:18.012 UTC] [V] OFSCtrl [/var/local/solajithome/function/output_fluctuation_suppression/batt_data] write success.
[2026-08-01 17:58:18.055 UTC] [V] OFSCtrl limit chk 400 < 800 < [1192->1192] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:18.055 UTC] [V] OFSCtrl angif value:1192 power_val_:20850.000000
[2026-08-01 17:58:18.155 UTC] [V] OFSCtrl limit chk 400 < 800 < [1192->1192] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:18.156 UTC] [V] OFSCtrl angif value:1192 power_val_:20850.000000
[2026-08-01 17:58:18.255 UTC] [V] OFSCtrl limit chk 400 < 800 < [1192->1192] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:18.255 UTC] [V] OFSCtrl angif value:1192 power_val_:20850.000000
[2026-08-01 17:58:18.355 UTC] [V] OFSCtrl limit chk 400 < 800 < [1192->1192] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:18.355 UTC] [V] OFSCtrl angif value:1192 power_val_:20850.000000
[2026-08-01 17:58:18.455 UTC] [V] OFSCtrl limit chk 400 < 800 < [1192->1192] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:18.455 UTC] [V] OFSCtrl angif value:1192 power_val_:20850.000000
[2026-08-01 17:58:18.555 UTC] [V] OFSCtrl limit chk 400 < 800 < [1192->1192] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:18.555 UTC] [V] OFSCtrl angif value:1192 power_val_:20850.000000
[2026-08-01 17:58:18.555 UTC] [V] OFSCtrl Control charge discharge proc start.
[2026-08-01 17:58:18.556 UTC] [V] OFSCtrl CHG 20 p_th(t):20719.650000 = p_th_old_:20749.350000 + lev_cd_:-0.300000 * (total_pcs_capacity_:297000.000000 * cof_spec_:2.000000 / 60 * (time_threshold_renew:10.000000 * 10)), min:-2062.500000, max:407900.000000
[2026-08-01 17:58:18.558 UTC] [V] OFSCtrl CHG 21 batt_w:20979.796079 = old:21052.676579 +  kp:0.550000 * e:-130.350000 + ki:0.000000 * sume:-13681.799856 + kd:0.040000 * (e:-130.350000 - e1:-100.650000)
[2026-08-01 17:58:18.559 UTC] [V] OFSCtrl CHG 21 battery threshold min:20000.000000 <= bat:20979.796079 <= max:196000.000000, adjust charge:0.000000, discharge:1000.000000
[2026-08-01 17:58:18.560 UTC] [V] OFSCtrl CHG 29 q:52.000000, mod(round):2.000000
[2026-08-01 17:58:18.561 UTC] [V] OFSCtrl discharge bat_w[0303]:6300.000000 += adjust:1000.000000
[2026-08-01 17:58:18.565 UTC] [D] OFSCtrl battery ctrl val:10.500000
[2026-08-01 17:58:18.569 UTC] [V] 485ChCtl <C3> battery limit on [52.000000,53.000000,63.000000,52.000000,] request.
[2026-08-01 17:58:18.569 UTC] [V] OFSCtrl Control charge discharge proc:01->02->BATT_CHK->03->04->05->06->10->12->13->15->16->18->19->20->21->22->23->24->25->27->23->24->25->27->23->24->25->27->23->24->25->27->28->29->30->31->32->30->31->32->30->31->32->30->31->32->33->34
[2026-08-01 17:58:18.578 UTC] [V] 485ChCtl <C3> battery send request.1
[2026-08-01 17:58:18.579 UTC] [D] VarInf Limit_Bat rt[2]set val[52] set rate[10.400000] value100[500] value-100[-500]
[2026-08-01 17:58:18.580 UTC] [D] VarInf Limit_Bat rt[2]set val[53] set rate[10.600000] value100[500] value-100[-500]
[2026-08-01 17:58:18.581 UTC] [D] VarInf Limit_Bat rt[2]set val[63] set rate[12.600000] value100[500] value-100[-500]
[2026-08-01 17:58:18.586 UTC] [D] VarInf Limit_Bat rt[2]set val[52] set rate[10.400000] value100[500] value-100[-500]
[2026-08-01 17:58:18.613 UTC] [D] 485AcReq <C3:01> PutOStream [6][0f000001000000090110278e0001020034]
[2026-08-01 17:58:18.613 UTC] [D] 485AcReq <C3:02> PutOStream [6][0f000001000000090110278e0001020035]
[2026-08-01 17:58:18.614 UTC] [D] 485AcReq <C3:03> PutOStream [6][0f000001000000090110278e000102003f]
[2026-08-01 17:58:18.616 UTC] [D] 485AcReq <C3:04> PutOStream [6][0f000001000000090110278e0001020034]
[2026-08-01 17:58:18.656 UTC] [V] OFSCtrl limit chk 400 < 800 < [1192->1192] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:18.656 UTC] [V] OFSCtrl angif value:1192 power_val_:20850.000000
[2026-08-01 17:58:18.755 UTC] [V] OFSCtrl limit chk 400 < 800 < [1192->1192] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:18.755 UTC] [V] OFSCtrl angif value:1192 power_val_:20850.000000
[2026-08-01 17:58:18.794 UTC] [V] 485DevCtl <C3:01> AnalyzeResponseData proc restart cnt:17978 UPRstat:0
[2026-08-01 17:58:18.797 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:58:18.798 UTC] [D] 485DevCtl <C3:01> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:58:18.798 UTC] [D] 485DevCtl <C3:01> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:58:18.798 UTC] [V] 485DevCtl <C3:01> device_type:Battery
[2026-08-01 17:58:18.798 UTC] [V] 485DevCtl <C3:02> AnalyzeResponseData proc restart cnt:17978 UPRstat:0
[2026-08-01 17:58:18.800 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:58:18.817 UTC] [D] 485DevCtl <C3:02> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:58:18.818 UTC] [D] 485DevCtl <C3:02> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:58:18.819 UTC] [V] 485DevCtl <C3:02> device_type:Battery
[2026-08-01 17:58:18.825 UTC] [V] 485DevCtl <C3:03> AnalyzeResponseData proc restart cnt:17978 UPRstat:0
[2026-08-01 17:58:18.846 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:58:18.850 UTC] [D] 485DevCtl <C3:03> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:58:18.851 UTC] [D] 485DevCtl <C3:03> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:58:18.852 UTC] [V] 485DevCtl <C3:03> device_type:Battery
[2026-08-01 17:58:18.855 UTC] [V] OFSCtrl limit chk 400 < 800 < [1192->1192] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:18.855 UTC] [V] OFSCtrl angif value:1192 power_val_:20850.000000
[2026-08-01 17:58:18.861 UTC] [V] 485DevCtl <C3:04> AnalyzeResponseData proc restart cnt:17978 UPRstat:0
[2026-08-01 17:58:18.879 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:58:18.884 UTC] [D] 485DevCtl <C3:04> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:58:18.886 UTC] [D] 485DevCtl <C3:04> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:58:18.890 UTC] [V] 485DevCtl <C3:04> device_type:Battery
[2026-08-01 17:58:18.898 UTC] [V] 485ChCtl <C3> set rt:0
[2026-08-01 17:58:18.955 UTC] [V] OFSCtrl limit chk 400 < 800 < [1192->1192] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:18.955 UTC] [V] OFSCtrl angif value:1192 power_val_:20850.000000
[2026-08-01 17:58:19.012 UTC] [V] OFSCtrl [/var/local/solajithome/function/output_fluctuation_suppression/batt_data] write success.
[2026-08-01 17:58:19.055 UTC] [V] OFSCtrl limit chk 400 < 800 < [1191->1191] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:19.055 UTC] [V] OFSCtrl angif value:1191 power_val_:20643.750000
[2026-08-01 17:58:19.155 UTC] [V] OFSCtrl limit chk 400 < 800 < [1190->1190] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:19.156 UTC] [V] OFSCtrl angif value:1190 power_val_:20437.500000
[2026-08-01 17:58:19.255 UTC] [V] OFSCtrl limit chk 400 < 800 < [1191->1191] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:19.255 UTC] [V] OFSCtrl angif value:1191 power_val_:20643.750000
[2026-08-01 17:58:19.355 UTC] [V] OFSCtrl limit chk 400 < 800 < [1191->1191] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:19.355 UTC] [V] OFSCtrl angif value:1191 power_val_:20643.750000
[2026-08-01 17:58:19.455 UTC] [V] OFSCtrl limit chk 400 < 800 < [1191->1191] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:19.455 UTC] [V] OFSCtrl angif value:1191 power_val_:20643.750000
[2026-08-01 17:58:19.555 UTC] [V] OFSCtrl limit chk 400 < 800 < [1191->1191] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:19.555 UTC] [V] OFSCtrl angif value:1191 power_val_:20643.750000
[2026-08-01 17:58:19.555 UTC] [V] OFSCtrl Control charge discharge proc start.
[2026-08-01 17:58:19.555 UTC] [V] OFSCtrl CHG 20 p_th(t):20689.950000 = p_th_old_:20719.650000 + lev_cd_:-0.300000 * (total_pcs_capacity_:297000.000000 * cof_spec_:2.000000 / 60 * (time_threshold_renew:10.000000 * 10)), min:-2062.500000, max:407900.000000
[2026-08-01 17:58:19.556 UTC] [V] OFSCtrl CHG 21 batt_w:21012.268079 = old:20979.796079 +  kp:0.550000 * e:46.200000 + ki:0.000000 * sume:-13635.599856 + kd:0.040000 * (e:46.200000 - e1:-130.350000)
[2026-08-01 17:58:19.556 UTC] [V] OFSCtrl CHG 21 battery threshold min:20000.000000 <= bat:21012.268079 <= max:196000.000000, adjust charge:0.000000, discharge:1000.000000
[2026-08-01 17:58:19.556 UTC] [V] OFSCtrl CHG 29 q:52.000000, mod(round):2.000000
[2026-08-01 17:58:19.557 UTC] [V] OFSCtrl discharge bat_w[0303]:6300.000000 += adjust:1000.000000
[2026-08-01 17:58:19.557 UTC] [D] OFSCtrl battery ctrl val:10.500000
[2026-08-01 17:58:19.559 UTC] [V] 485ChCtl <C3> battery limit on [52.000000,53.000000,63.000000,52.000000,] request.
[2026-08-01 17:58:19.561 UTC] [V] OFSCtrl Control charge discharge proc:01->02->BATT_CHK->03->04->05->06->10->12->13->15->16->18->19->20->21->22->23->24->25->27->23->24->25->27->23->24->25->27->23->24->25->27->28->29->30->31->32->30->31->32->30->31->32->30->31->32->33->34
[2026-08-01 17:58:19.579 UTC] [V] 485ChCtl <C3> battery send request.1
[2026-08-01 17:58:19.580 UTC] [D] VarInf Limit_Bat rt[2]set val[52] set rate[10.400000] value100[500] value-100[-500]
[2026-08-01 17:58:19.581 UTC] [D] VarInf Limit_Bat rt[2]set val[53] set rate[10.600000] value100[500] value-100[-500]
[2026-08-01 17:58:19.581 UTC] [D] VarInf Limit_Bat rt[2]set val[63] set rate[12.600000] value100[500] value-100[-500]
[2026-08-01 17:58:19.600 UTC] [D] VarInf Limit_Bat rt[2]set val[52] set rate[10.400000] value100[500] value-100[-500]
[2026-08-01 17:58:19.606 UTC] [D] 485AcReq <C3:01> PutOStream [6][0f000001000000090110278e0001020034]
[2026-08-01 17:58:19.607 UTC] [D] 485AcReq <C3:02> PutOStream [6][0f000001000000090110278e0001020035]
[2026-08-01 17:58:19.608 UTC] [D] 485AcReq <C3:03> PutOStream [6][0f000001000000090110278e000102003f]
[2026-08-01 17:58:19.610 UTC] [D] 485AcReq <C3:04> PutOStream [6][0f000001000000090110278e0001020034]
[2026-08-01 17:58:19.655 UTC] [V] OFSCtrl limit chk 400 < 800 < [1191->1191] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:19.655 UTC] [V] OFSCtrl angif value:1191 power_val_:20643.750000
[2026-08-01 17:58:19.755 UTC] [V] OFSCtrl limit chk 400 < 800 < [1191->1191] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:19.755 UTC] [V] OFSCtrl angif value:1191 power_val_:20643.750000
[2026-08-01 17:58:19.784 UTC] [V] 485DevCtl <C3:01> AnalyzeResponseData proc restart cnt:17979 UPRstat:0
[2026-08-01 17:58:19.787 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:58:19.788 UTC] [D] 485DevCtl <C3:01> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:58:19.788 UTC] [D] 485DevCtl <C3:01> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:58:19.788 UTC] [V] 485DevCtl <C3:01> device_type:Battery
[2026-08-01 17:58:19.789 UTC] [V] 485DevCtl <C3:02> AnalyzeResponseData proc restart cnt:17979 UPRstat:0
[2026-08-01 17:58:19.803 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:58:19.810 UTC] [D] 485DevCtl <C3:02> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:58:19.811 UTC] [D] 485DevCtl <C3:02> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:58:19.813 UTC] [V] 485DevCtl <C3:02> device_type:Battery
[2026-08-01 17:58:19.818 UTC] [V] 485DevCtl <C3:03> AnalyzeResponseData proc restart cnt:17979 UPRstat:0
[2026-08-01 17:58:19.837 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:58:19.844 UTC] [D] 485DevCtl <C3:03> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:58:19.850 UTC] [D] 485DevCtl <C3:03> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:58:19.851 UTC] [V] 485DevCtl <C3:03> device_type:Battery
[2026-08-01 17:58:19.853 UTC] [V] 485DevCtl <C3:04> AnalyzeResponseData proc restart cnt:17979 UPRstat:0
[2026-08-01 17:58:19.855 UTC] [V] OFSCtrl limit chk 400 < 800 < [1191->1191] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:19.855 UTC] [V] OFSCtrl angif value:1191 power_val_:20643.750000
[2026-08-01 17:58:19.860 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:58:19.867 UTC] [D] 485DevCtl <C3:04> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:58:19.868 UTC] [D] 485DevCtl <C3:04> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:58:19.869 UTC] [V] 485DevCtl <C3:04> device_type:Battery
[2026-08-01 17:58:19.873 UTC] [V] 485ChCtl <C3> set rt:0
[2026-08-01 17:58:19.955 UTC] [V] OFSCtrl limit chk 400 < 800 < [1191->1191] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:19.955 UTC] [V] OFSCtrl angif value:1191 power_val_:20643.750000
[2026-08-01 17:58:20.012 UTC] [V] OFSCtrl [/var/local/solajithome/function/output_fluctuation_suppression/batt_data] write success.
[2026-08-01 17:58:20.056 UTC] [V] OFSCtrl limit chk 400 < 800 < [1191->1191] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:20.056 UTC] [V] OFSCtrl angif value:1191 power_val_:20643.750000
[2026-08-01 17:58:20.155 UTC] [V] OFSCtrl limit chk 400 < 800 < [1191->1191] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:20.156 UTC] [V] OFSCtrl angif value:1191 power_val_:20643.750000
[2026-08-01 17:58:20.255 UTC] [V] OFSCtrl limit chk 400 < 800 < [1191->1191] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:20.255 UTC] [V] OFSCtrl angif value:1191 power_val_:20643.750000
[2026-08-01 17:58:20.355 UTC] [V] OFSCtrl limit chk 400 < 800 < [1191->1191] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:20.355 UTC] [V] OFSCtrl angif value:1191 power_val_:20643.750000
[2026-08-01 17:58:20.455 UTC] [V] OFSCtrl limit chk 400 < 800 < [1191->1191] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:20.455 UTC] [V] OFSCtrl angif value:1191 power_val_:20643.750000
[2026-08-01 17:58:20.555 UTC] [V] OFSCtrl limit chk 400 < 800 < [1191->1191] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:20.555 UTC] [V] OFSCtrl angif value:1191 power_val_:20643.750000
[2026-08-01 17:58:20.555 UTC] [V] OFSCtrl Control charge discharge proc start.
[2026-08-01 17:58:20.555 UTC] [V] OFSCtrl CHG 20 p_th(t):20660.250000 = p_th_old_:20689.950000 + lev_cd_:-0.300000 * (total_pcs_capacity_:297000.000000 * cof_spec_:2.000000 / 60 * (time_threshold_renew:10.000000 * 10)), min:-2062.500000, max:407900.000000
[2026-08-01 17:58:20.556 UTC] [V] OFSCtrl CHG 21 batt_w:21020.155079 = old:21012.268079 +  kp:0.550000 * e:16.500000 + ki:0.000000 * sume:-13619.099856 + kd:0.040000 * (e:16.500000 - e1:46.200000)
[2026-08-01 17:58:20.558 UTC] [V] OFSCtrl CHG 21 battery threshold min:20000.000000 <= bat:21020.155079 <= max:196000.000000, adjust charge:0.000000, discharge:1000.000000
[2026-08-01 17:58:20.558 UTC] [V] OFSCtrl CHG 29 q:52.000000, mod(round):2.000000
[2026-08-01 17:58:20.559 UTC] [V] OFSCtrl discharge bat_w[0303]:6300.000000 += adjust:1000.000000
[2026-08-01 17:58:20.560 UTC] [D] OFSCtrl battery ctrl val:10.500000
[2026-08-01 17:58:20.564 UTC] [V] 485ChCtl <C3> battery limit on [52.000000,53.000000,63.000000,52.000000,] request.
[2026-08-01 17:58:20.565 UTC] [V] OFSCtrl Control charge discharge proc:01->02->BATT_CHK->03->04->05->06->10->12->13->15->16->18->19->20->21->22->23->24->25->27->23->24->25->27->23->24->25->27->23->24->25->27->28->29->30->31->32->30->31->32->30->31->32->30->31->32->33->34
[2026-08-01 17:58:20.578 UTC] [V] 485ChCtl <C3> battery send request.1
[2026-08-01 17:58:20.579 UTC] [D] VarInf Limit_Bat rt[2]set val[52] set rate[10.400000] value100[500] value-100[-500]
[2026-08-01 17:58:20.580 UTC] [D] VarInf Limit_Bat rt[2]set val[53] set rate[10.600000] value100[500] value-100[-500]
[2026-08-01 17:58:20.581 UTC] [D] VarInf Limit_Bat rt[2]set val[63] set rate[12.600000] value100[500] value-100[-500]
[2026-08-01 17:58:20.582 UTC] [D] VarInf Limit_Bat rt[2]set val[52] set rate[10.400000] value100[500] value-100[-500]
[2026-08-01 17:58:20.606 UTC] [D] 485AcReq <C3:01> PutOStream [6][0f000001000000090110278e0001020034]
[2026-08-01 17:58:20.607 UTC] [D] 485AcReq <C3:02> PutOStream [6][0f000001000000090110278e0001020035]
[2026-08-01 17:58:20.608 UTC] [D] 485AcReq <C3:03> PutOStream [6][0f000001000000090110278e000102003f]
[2026-08-01 17:58:20.608 UTC] [D] 485AcReq <C3:04> PutOStream [6][0f000001000000090110278e0001020034]
[2026-08-01 17:58:20.631 UTC] [V] CIStDb UpdateStatusData. [SELECT no, on_time, off_time FROM contact_input_status WHERE no BETWEEN '1' AND '9' ORDER BY no ASC ]
[2026-08-01 17:58:20.655 UTC] [V] OFSCtrl limit chk 400 < 800 < [1191->1191] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:20.655 UTC] [V] OFSCtrl angif value:1191 power_val_:20643.750000
[2026-08-01 17:58:20.755 UTC] [V] OFSCtrl limit chk 400 < 800 < [1191->1191] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:20.755 UTC] [V] OFSCtrl angif value:1191 power_val_:20643.750000
[2026-08-01 17:58:20.756 UTC] [V] 485DevCtl <C1:01> device_type:Irr-Meter
[2026-08-01 17:58:20.756 UTC] [V] 485DevCtl <C1:01> device_type:Irr-Meter
[2026-08-01 17:58:20.757 UTC] [V] 485ChCtl <C1> fixed cycle Irr-Meter
[2026-08-01 17:58:20.757 UTC] [V] 485DevCtl <C1:01> Dev not PCS IsNeedToChangeOControlState
[2026-08-01 17:58:20.757 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :1
[2026-08-01 17:58:20.758 UTC] [V] 485ChCtl <C1> send request:Irr01
[2026-08-01 17:58:20.758 UTC] [D] 485AcReq <C1:01> PutOStream [1][080001040000000271cb]
[2026-08-01 17:58:20.774 UTC] [V] 485DevCtl <C3:01> AnalyzeResponseData proc restart cnt:17980 UPRstat:0
[2026-08-01 17:58:20.776 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:58:20.778 UTC] [D] 485DevCtl <C3:01> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:58:20.778 UTC] [D] 485DevCtl <C3:01> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:58:20.779 UTC] [V] 485DevCtl <C3:01> device_type:Battery
[2026-08-01 17:58:20.785 UTC] [V] 485DevCtl <C3:02> AnalyzeResponseData proc restart cnt:17980 UPRstat:0
[2026-08-01 17:58:20.808 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:58:20.815 UTC] [D] 485DevCtl <C3:02> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:58:20.817 UTC] [D] 485DevCtl <C3:02> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:58:20.822 UTC] [V] 485DevCtl <C3:02> device_type:Battery
[2026-08-01 17:58:20.823 UTC] [V] 485DevCtl <C3:03> AnalyzeResponseData proc restart cnt:17980 UPRstat:0
[2026-08-01 17:58:20.842 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:58:20.843 UTC] [D] 485DevCtl <C3:03> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:58:20.843 UTC] [D] 485DevCtl <C3:03> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:58:20.843 UTC] [V] 485DevCtl <C3:03> device_type:Battery
[2026-08-01 17:58:20.843 UTC] [V] 485DevCtl <C3:04> AnalyzeResponseData proc restart cnt:17980 UPRstat:0
[2026-08-01 17:58:20.855 UTC] [V] OFSCtrl limit chk 400 < 800 < [1191->1191] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:20.855 UTC] [V] OFSCtrl angif value:1191 power_val_:20643.750000
[2026-08-01 17:58:20.865 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:58:20.865 UTC] [D] 485DevCtl <C3:04> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:58:20.865 UTC] [D] 485DevCtl <C3:04> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:58:20.866 UTC] [V] 485DevCtl <C3:04> device_type:Battery
[2026-08-01 17:58:20.866 UTC] [V] 485ChCtl <C3> set rt:0
[2026-08-01 17:58:20.955 UTC] [V] OFSCtrl limit chk 400 < 800 < [1191->1191] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:20.956 UTC] [V] OFSCtrl angif value:1191 power_val_:20643.750000
[2026-08-01 17:58:21.013 UTC] [V] OFSCtrl [/var/local/solajithome/function/output_fluctuation_suppression/batt_data] write success.
[2026-08-01 17:58:21.055 UTC] [V] OFSCtrl limit chk 400 < 800 < [1191->1191] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:21.055 UTC] [V] OFSCtrl angif value:1191 power_val_:20643.750000
[2026-08-01 17:58:21.096 UTC] [V] 485DevCtl <C1:01> AnalyzeResponseData proc restart cnt:17998 UPRstat:0
[2026-08-01 17:58:21.096 UTC] [V] Res no response condition. set normal condition.
[2026-08-01 17:58:21.097 UTC] [D] 485DevCtl <C1:01> RcvDat status[2] len[9] [010404000001fa7a57]
[2026-08-01 17:58:21.097 UTC] [D] 485DevCtl <C1:01> ResCnd OperationId [1] IsNormal[1] 
[2026-08-01 17:58:21.097 UTC] [V] OFSCtrl Rcv set flux_of_solar:0.000000
[2026-08-01 17:58:21.097 UTC] [V] 485DevCtl <C1:01> [01][401006][0.000000][1][W/m2]
[2026-08-01 17:58:21.097 UTC] [V] SummDat SetVrmValue dev_id:1 val:0.000000 sc:3
[2026-08-01 17:58:21.098 UTC] [V] OCMgr SetMeterValue PhId:0101, branchNo:01, valueId:401006, value:0.000000, scaleFactor:1, devId:1
[2026-08-01 17:58:21.098 UTC] [V] 485DevCtl <C1:01> [01][421005][256.000000][1][℃]
[2026-08-01 17:58:21.098 UTC] [V] SummDat SetVrmValue dev_id:1 val:25600.000000 sc:3
[2026-08-01 17:58:21.098 UTC] [V] OCMgr SetMeterValue PhId:0101, branchNo:01, valueId:421005, value:256.000000, scaleFactor:1, devId:1
[2026-08-01 17:58:21.098 UTC] [V] 485DevCtl <C1:01> device_type:Irr-Meter
[2026-08-01 17:58:21.099 UTC] [V] OFSCtrl Irr-Meter received.
[2026-08-01 17:58:21.099 UTC] [V] 485ChCtl <C1> set rt:0
[2026-08-01 17:58:21.102 UTC] [V] 485DevCtl <C1:01> device_type:Irr-Meter
[2026-08-01 17:58:21.155 UTC] [V] OFSCtrl limit chk 400 < 800 < [1191->1191] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:21.155 UTC] [V] OFSCtrl angif value:1191 power_val_:20643.750000
[2026-08-01 17:58:21.156 UTC] [V] 485DevCtl <C1:04> device_type:CO-Meter
[2026-08-01 17:58:21.156 UTC] [V] 485DevCtl <C1:04> device_type:CO-Meter
[2026-08-01 17:58:21.156 UTC] [V] 485ChCtl <C1> fixed cycle CO-Meter
[2026-08-01 17:58:21.157 UTC] [V] 485DevCtl <C1:04> Dev not PCS IsNeedToChangeOControlState
[2026-08-01 17:58:21.157 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :1
[2026-08-01 17:58:21.157 UTC] [V] 485ChCtl <C1> send request:omron05
[2026-08-01 17:58:21.158 UTC] [D] 485AcReq <C1:04> PutOStream [1][0800040300030014b590]
[2026-08-01 17:58:21.255 UTC] [V] OFSCtrl limit chk 400 < 800 < [1191->1191] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:21.255 UTC] [V] OFSCtrl angif value:1191 power_val_:20643.750000
[2026-08-01 17:58:21.355 UTC] [V] OFSCtrl limit chk 400 < 800 < [1191->1191] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:21.355 UTC] [V] OFSCtrl angif value:1191 power_val_:20643.750000
[2026-08-01 17:58:21.455 UTC] [V] OFSCtrl limit chk 400 < 800 < [1191->1191] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:21.455 UTC] [V] OFSCtrl angif value:1191 power_val_:20643.750000
[2026-08-01 17:58:21.478 UTC] [V] 485ChCtl <C3> StartDeviceCommunicationForOutputFluctuationSuppressionControlBroadcast 4 cnt:179757, monitor_cnt:50, bc_elapsed:179757, min:10, max:40
[2026-08-01 17:58:21.479 UTC] [V] OFSCtrl /var/local/solajithome/function/output_fluctuation_suppression/state is exist:0
[2026-08-01 17:58:21.479 UTC] [V] 485DevCtl <C3:01> Dev not PCS IsNeedToChangeOControlState
[2026-08-01 17:58:21.479 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :2
[2026-08-01 17:58:21.480 UTC] [V] 485ChCtl <C3> send request:Sungrow11
[2026-08-01 17:58:21.481 UTC] [D] 485AcReq <C3:01> PutOStream [2][0c0000010000000601042751005e]
[2026-08-01 17:58:21.556 UTC] [V] OFSCtrl limit chk 400 < 800 < [1191->1191] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:21.556 UTC] [V] OFSCtrl angif value:1191 power_val_:20643.750000
[2026-08-01 17:58:21.556 UTC] [V] OFSCtrl Control charge discharge proc start.
[2026-08-01 17:58:21.556 UTC] [V] OFSCtrl CHG 20 p_th(t):20630.550000 = p_th_old_:20660.250000 + lev_cd_:-0.300000 * (total_pcs_capacity_:297000.000000 * cof_spec_:2.000000 / 60 * (time_threshold_renew:10.000000 * 10)), min:-2062.500000, max:407900.000000
[2026-08-01 17:58:21.557 UTC] [V] OFSCtrl CHG 21 batt_w:21011.707079 = old:21020.155079 +  kp:0.550000 * e:-13.200000 + ki:0.000000 * sume:-13632.299856 + kd:0.040000 * (e:-13.200000 - e1:16.500000)
[2026-08-01 17:58:21.557 UTC] [V] OFSCtrl CHG 21 battery threshold min:20000.000000 <= bat:21011.707079 <= max:196000.000000, adjust charge:0.000000, discharge:1000.000000
[2026-08-01 17:58:21.557 UTC] [V] OFSCtrl CHG 29 q:52.000000, mod(round):2.000000
[2026-08-01 17:58:21.557 UTC] [V] OFSCtrl discharge bat_w[0303]:6300.000000 += adjust:1000.000000
[2026-08-01 17:58:21.557 UTC] [D] OFSCtrl battery ctrl val:10.500000
[2026-08-01 17:58:21.558 UTC] [V] 485ChCtl <C3> battery limit on [52.000000,53.000000,63.000000,52.000000,] request.
[2026-08-01 17:58:21.558 UTC] [V] OFSCtrl Control charge discharge proc:01->02->BATT_CHK->03->04->05->06->10->12->13->15->16->18->19->20->21->22->23->24->25->27->23->24->25->27->23->24->25->27->23->24->25->27->28->29->30->31->32->30->31->32->30->31->32->30->31->32->33->34
[2026-08-01 17:58:21.561 UTC] [V] 485DevCtl <C1:04> AnalyzeResponseData proc restart cnt:17998 UPRstat:0
[2026-08-01 17:58:21.562 UTC] [V] Res no response condition. set normal condition.
[2026-08-01 17:58:21.563 UTC] [D] 485DevCtl <C1:04> RcvDat status[2] len[45] [0403280000f1590000f86a0000e08f000000640000025800033dd10000084cffffbef5ffffff5a00233b04a4f1]
[2026-08-01 17:58:21.563 UTC] [D] 485DevCtl <C1:04> ResCnd OperationId [1] IsNormal[1] 
[2026-08-01 17:58:21.564 UTC] [V] OFSCtrl Rcv set p_co:21240.000000, p_co_old:21370.000000
[2026-08-01 17:58:21.564 UTC] [V] 485DevCtl <C1:04> [01][601260][2124.000000][2][kW]
[2026-08-01 17:58:21.564 UTC] [V] SummDat SetVrmValue dev_id:4 val:21240.000000 sc:3
[2026-08-01 17:58:21.564 UTC] [V] OCMgr SetMeterValue PhId:0104, branchNo:01, valueId:601260, value:2124.000000, scaleFactor:2, devId:4
[2026-08-01 17:58:21.566 UTC] [V] 485DevCtl <C1:04> [01][603260][2308868.000000][1][kWh]
[2026-08-01 17:58:21.568 UTC] [V] SummDat SetVrmValue dev_id:4 val:2308868.000000 sc:1
[2026-08-01 17:58:21.575 UTC] [V] OCMgr SetMeterValue PhId:0104, branchNo:01, valueId:603260, value:2308868.000000, scaleFactor:1, devId:4
[2026-08-01 17:58:21.575 UTC] [V] 485DevCtl <C1:04> device_type:CO-Meter
[2026-08-01 17:58:21.575 UTC] [V] OFSCtrl km50 received.
[2026-08-01 17:58:21.576 UTC] [V] OFSCtrl omron05_local_date :2026/08/02 ? 2026/08/02
[2026-08-01 17:58:21.576 UTC] [V] OFSCtrl omron05_local_time :2026/08/02 02 ? 2026/08/02 02
[2026-08-01 17:58:21.584 UTC] [V] OFSCtrl out of control time.
[2026-08-01 17:58:21.585 UTC] [V] OFSCtrl Control pv-pcs proc start.
[2026-08-01 17:58:21.585 UTC] [V] OFSCtrl NOD_month:-445.000000 = (NOD_month:13 - ((nod_max_/30):23.333333 * (cnt-1):12) * (30/cnt):1.666667 
[2026-08-01 17:58:21.585 UTC] [V] OFSCtrl PCS ratio_month:113.496241 = -k_inhibition_ratio_month:-0.097744 * NOD_month:-445.000000 + inhibition_ratio_max:70
[2026-08-01 17:58:21.585 UTC] [V] OFSCtrl PCS 05 inhibition_ratio:70.000000 = max(ratio_min:5, min(ratio:70, ratio_hour:70.000000, ratio_day:70.000000, ratio_month:113.496241))
[2026-08-01 17:58:21.586 UTC] [D] OFSCtrl pv-pcs ctrl val:0.000000 old:0.000000
[2026-08-01 17:58:21.586 UTC] [V] OCHisDB set rate:0 t_rate:0 cnt:37
[2026-08-01 17:58:21.586 UTC] [V] 485ChCtl <C2> pv-pcs limit on [0.000000] request.
[2026-08-01 17:58:21.586 UTC] [V] OFSCtrl Control pv-pcs proc:BATT_CHK->01->02->03->04->05->06->07->09->09->10->11->12
[2026-08-01 17:58:21.586 UTC] [V] 485ChCtl <C1> set rt:0
[2026-08-01 17:58:21.605 UTC] [V] 485DevCtl <C1:04> device_type:CO-Meter
[2026-08-01 17:58:21.656 UTC] [V] OFSCtrl limit chk 400 < 800 < [1191->1191] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:21.656 UTC] [V] OFSCtrl angif value:1191 power_val_:20643.750000
[2026-08-01 17:58:21.664 UTC] [V] 485ChCtl <C2> pv-pcs send request.
[2026-08-01 17:58:21.664 UTC] [D] VarInf update ofs_rate:0.000000
[2026-08-01 17:58:21.664 UTC] [V] VarInf LimitSet rt[2] val[170] key[ValueOn]
[2026-08-01 17:58:21.665 UTC] [D] VarInf output_mode:8
[2026-08-01 17:58:21.665 UTC] [D] VarInf update ofs_rate:0.000000
[2026-08-01 17:58:21.666 UTC] [D] VarInf Limit setRate[0.000000] rate[0.000000] value100[1000.000000] value0[0.000000]
[2026-08-01 17:58:21.666 UTC] [V] 485DevCtl <C2:01> ChangeOutputRateToDevice rate:0.000000 set_rate1
[2026-08-01 17:58:21.666 UTC] [D] VarInf Limit rt[2] int_set_rate[1] server_rate[0.000000] rated_output[100.000000] solar_battery_power[100.000000]
[2026-08-01 17:58:21.667 UTC] [D] 485AcReq <C2:01> PutOStreamForBc [3][0d000010138e00020400aa0001466f]
[2026-08-01 17:58:21.673 UTC] [V] 485DevCtl <C3:01> AnalyzeResponseData proc restart cnt:17981 UPRstat:0
[2026-08-01 17:58:21.716 UTC] [D] 485DevCtl <C3:01> RcvDat status[0] len[197] [0001000000bf0104bc0000ffffffffffff01fe00000000001000000000000000000000000000000000000000ae0032009a0000000100010001ffffffffffffffffffffffffffffffffffffffff000100000001000000010000ffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffff000101f40000003400000000000003e8458a00003e9f00000000000000ad0000]
[2026-08-01 17:58:21.717 UTC] [D] 485DevCtl <C3:01> ResCnd OperationId [2] IsNormal[1]  ConditionType [lggrdev:Normal] Action[-1]
[2026-08-01 17:58:21.717 UTC] [V] 485DevCtl <C3:01> [02][753049][0.000000][0][]
[2026-08-01 17:58:21.717 UTC] [V] SummDat SetVrmValue dev_id:13 val:0.000000 sc:0
[2026-08-01 17:58:21.718 UTC] [V] OCMgr SetMeterValue PhId:0301, branchNo:02, valueId:753049, value:0.000000, scaleFactor:0, devId:13
[2026-08-01 17:58:21.718 UTC] [V] 485DevCtl <C3:01> [01][753040][16.000000][0][]
[2026-08-01 17:58:21.718 UTC] [V] SummDat SetVrmValue dev_id:13 val:16.000000 sc:0
[2026-08-01 17:58:21.718 UTC] [V] OCMgr SetMeterValue PhId:0301, branchNo:01, valueId:753040, value:16.000000, scaleFactor:0, devId:13
[2026-08-01 17:58:21.719 UTC] [V] 485DevCtl <C3:01> [01][753053][0.000000][0][]
[2026-08-01 17:58:21.719 UTC] [V] SummDat SetVrmValue dev_id:13 val:0.000000 sc:0
[2026-08-01 17:58:21.719 UTC] [V] OCMgr SetMeterValue PhId:0301, branchNo:01, valueId:753053, value:0.000000, scaleFactor:0, devId:13
[2026-08-01 17:58:21.719 UTC] [V] 485DevCtl <C3:01> [02][753053][0.000000][0][]
[2026-08-01 17:58:21.719 UTC] [V] SummDat SetVrmValue dev_id:13 val:0.000000 sc:0
[2026-08-01 17:58:21.749 UTC] [V] OCMgr SetMeterValue PhId:0301, branchNo:02, valueId:753053, value:0.000000, scaleFactor:0, devId:13
[2026-08-01 17:58:21.755 UTC] [V] OFSCtrl limit chk 400 < 800 < [1191->1191] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:21.755 UTC] [V] OFSCtrl angif value:1191 power_val_:20643.750000
[2026-08-01 17:58:21.757 UTC] [V] 485DevCtl <C3:01> [03][753053][0.000000][0][]
[2026-08-01 17:58:21.761 UTC] [V] SummDat SetVrmValue dev_id:13 val:0.000000 sc:0
[2026-08-01 17:58:21.761 UTC] [V] OCMgr SetMeterValue PhId:0301, branchNo:03, valueId:753053, value:0.000000, scaleFactor:0, devId:13
[2026-08-01 17:58:21.761 UTC] [V] 485DevCtl <C3:01> [04][753053][0.000000][0][]
[2026-08-01 17:58:21.762 UTC] [V] SummDat SetVrmValue dev_id:13 val:0.000000 sc:0
[2026-08-01 17:58:21.769 UTC] [V] OCMgr SetMeterValue PhId:0301, branchNo:04, valueId:753053, value:0.000000, scaleFactor:0, devId:13
[2026-08-01 17:58:21.772 UTC] [V] 485DevCtl <C3:01> [01][716202][500.000000][1][kW]
[2026-08-01 17:58:21.775 UTC] [V] SummDat SetVrmValue dev_id:13 val:50000.000000 sc:3
[2026-08-01 17:58:21.795 UTC] [V] OCMgr SetMeterValue PhId:0301, branchNo:01, valueId:716202, value:500.000000, scaleFactor:1, devId:13
[2026-08-01 17:58:21.795 UTC] [V] 485DevCtl <C3:01> [01][711102][52.000000][1][kW]
[2026-08-01 17:58:21.795 UTC] [V] SummDat SetVrmValue dev_id:13 val:5200.000000 sc:3
[2026-08-01 17:58:21.806 UTC] [V] OCMgr SetMeterValue PhId:0301, branchNo:01, valueId:711102, value:52.000000, scaleFactor:1, devId:13
[2026-08-01 17:58:21.811 UTC] [V] 485DevCtl <C3:01> [01][703102][17802.000000][0][kWh]
[2026-08-01 17:58:21.811 UTC] [V] SummDat SetVrmValue dev_id:13 val:17802.000000 sc:0
[2026-08-01 17:58:21.811 UTC] [V] OCMgr SetMeterValue PhId:0301, branchNo:01, valueId:703102, value:17802.000000, scaleFactor:0, devId:13
[2026-08-01 17:58:21.812 UTC] [V] 485DevCtl <C3:01> [01][713102][16031.000000][0][kWh]
[2026-08-01 17:58:21.812 UTC] [V] SummDat SetVrmValue dev_id:13 val:16031.000000 sc:0
[2026-08-01 17:58:21.831 UTC] [V] OCMgr SetMeterValue PhId:0301, branchNo:01, valueId:713102, value:16031.000000, scaleFactor:0, devId:13
[2026-08-01 17:58:21.835 UTC] [V] 485DevCtl <C3:01> device_type:Battery
[2026-08-01 17:58:21.846 UTC] [V] 485ChCtl <C3> set rt:0
[2026-08-01 17:58:21.855 UTC] [V] OFSCtrl limit chk 400 < 800 < [1191->1191] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:21.855 UTC] [V] OFSCtrl angif value:1191 power_val_:20643.750000
[2026-08-01 17:58:21.879 UTC] [V] 485ChCtl <C3> battery send request.1
[2026-08-01 17:58:21.879 UTC] [D] VarInf Limit_Bat rt[2]set val[52] set rate[10.400000] value100[500] value-100[-500]
[2026-08-01 17:58:21.880 UTC] [D] VarInf Limit_Bat rt[2]set val[53] set rate[10.600000] value100[500] value-100[-500]
[2026-08-01 17:58:21.881 UTC] [D] VarInf Limit_Bat rt[2]set val[63] set rate[12.600000] value100[500] value-100[-500]
[2026-08-01 17:58:21.898 UTC] [D] VarInf Limit_Bat rt[2]set val[52] set rate[10.400000] value100[500] value-100[-500]
[2026-08-01 17:58:21.905 UTC] [D] 485AcReq <C3:01> PutOStream [6][0f000001000000090110278e0001020034]
[2026-08-01 17:58:21.906 UTC] [D] 485AcReq <C3:02> PutOStream [6][0f000001000000090110278e0001020035]
[2026-08-01 17:58:21.906 UTC] [D] 485AcReq <C3:03> PutOStream [6][0f000001000000090110278e000102003f]
[2026-08-01 17:58:21.907 UTC] [D] 485AcReq <C3:04> PutOStream [6][0f000001000000090110278e0001020034]
[2026-08-01 17:58:21.955 UTC] [V] OFSCtrl limit chk 400 < 800 < [1191->1191] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:21.955 UTC] [V] OFSCtrl angif value:1191 power_val_:20643.750000
[2026-08-01 17:58:21.964 UTC] [V] 485ChCtl <C2> set rt:0
[2026-08-01 17:58:22.013 UTC] [V] OFSCtrl [/var/local/solajithome/function/output_fluctuation_suppression/batt_data] write success.
[2026-08-01 17:58:22.055 UTC] [V] OFSCtrl limit chk 400 < 800 < [1191->1191] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:22.055 UTC] [V] OFSCtrl angif value:1191 power_val_:20643.750000
[2026-08-01 17:58:22.074 UTC] [V] 485DevCtl <C3:01> AnalyzeResponseData proc restart cnt:17981 UPRstat:0
[2026-08-01 17:58:22.076 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:58:22.079 UTC] [D] 485DevCtl <C3:01> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:58:22.080 UTC] [D] 485DevCtl <C3:01> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:58:22.081 UTC] [V] 485DevCtl <C3:01> device_type:Battery
[2026-08-01 17:58:22.086 UTC] [V] 485DevCtl <C3:02> AnalyzeResponseData proc restart cnt:17981 UPRstat:0
[2026-08-01 17:58:22.108 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:58:22.109 UTC] [D] 485DevCtl <C3:02> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:58:22.109 UTC] [D] 485DevCtl <C3:02> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:58:22.109 UTC] [V] 485DevCtl <C3:02> device_type:Battery
[2026-08-01 17:58:22.109 UTC] [V] 485DevCtl <C3:03> AnalyzeResponseData proc restart cnt:17981 UPRstat:0
[2026-08-01 17:58:22.132 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:58:22.138 UTC] [D] 485DevCtl <C3:03> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:58:22.140 UTC] [D] 485DevCtl <C3:03> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:58:22.155 UTC] [V] OFSCtrl limit chk 400 < 800 < [1191->1191] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:22.155 UTC] [V] OFSCtrl angif value:1191 power_val_:20643.750000
[2026-08-01 17:58:22.162 UTC] [V] 485DevCtl <C3:03> device_type:Battery
[2026-08-01 17:58:22.163 UTC] [V] 485DevCtl <C3:04> AnalyzeResponseData proc restart cnt:17981 UPRstat:0
[2026-08-01 17:58:22.176 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:58:22.189 UTC] [D] 485DevCtl <C3:04> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:58:22.195 UTC] [D] 485DevCtl <C3:04> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:58:22.195 UTC] [V] 485DevCtl <C3:04> device_type:Battery
[2026-08-01 17:58:22.195 UTC] [V] 485ChCtl <C3> set rt:0
[2026-08-01 17:58:22.256 UTC] [V] OFSCtrl limit chk 400 < 800 < [1191->1191] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:22.256 UTC] [V] OFSCtrl angif value:1191 power_val_:20643.750000
[2026-08-01 17:58:22.279 UTC] [V] 485ChCtl <C3> StartDeviceCommunicationForOutputFluctuationSuppressionControlBroadcast 4 cnt:179765, monitor_cnt:58, bc_elapsed:179765, min:10, max:40
[2026-08-01 17:58:22.279 UTC] [V] 485DevCtl <C3:02> Dev not PCS IsNeedToChangeOControlState
[2026-08-01 17:58:22.279 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :5
[2026-08-01 17:58:22.280 UTC] [V] 485ChCtl <C3> send request:Sungrow11
[2026-08-01 17:58:22.281 UTC] [D] 485AcReq <C3:02> PutOStream [5][0c00000100000006010469780001]
[2026-08-01 17:58:22.355 UTC] [V] OFSCtrl limit chk 400 < 800 < [1191->1191] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:22.356 UTC] [V] OFSCtrl angif value:1191 power_val_:20643.750000
[2026-08-01 17:58:22.364 UTC] [V] 485ChCtl <C2> StartDeviceCommunicationForOutputFluctuationSuppressionControlBroadcast 4 cnt:179766, monitor_cnt:50, bc_elapsed:179766, min:10, max:40
[2026-08-01 17:58:22.365 UTC] [V] OFSCtrl /var/local/solajithome/function/output_fluctuation_suppression/state is exist:0
[2026-08-01 17:58:22.365 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :1
[2026-08-01 17:58:22.366 UTC] [V] 485ChCtl <C2> send request:Sungrow08
[2026-08-01 17:58:22.367 UTC] [D] 485AcReq <C2:01> PutOStream [1][08000104138a0024d57f]
[2026-08-01 17:58:22.403 UTC] [V] 485DevCtl <C3:02> AnalyzeResponseData proc restart cnt:17981 UPRstat:0
[2026-08-01 17:58:22.404 UTC] [D] 485DevCtl <C3:02> RcvDat status[0] len[11] [000100000005010402012b]
[2026-08-01 17:58:22.405 UTC] [D] 485DevCtl <C3:02> ResCnd OperationId [5] IsNormal[1]  ConditionType [lggrdev:Normal] Action[-1]
[2026-08-01 17:58:22.405 UTC] [V] 485DevCtl <C3:02> [01][121005][299.000000][1][℃]
[2026-08-01 17:58:22.406 UTC] [V] SummDat SetVrmValue dev_id:14 val:29900.000000 sc:3
[2026-08-01 17:58:22.406 UTC] [V] OCMgr SetMeterValue PhId:0302, branchNo:01, valueId:121005, value:299.000000, scaleFactor:1, devId:14
[2026-08-01 17:58:22.406 UTC] [V] 485DevCtl <C3:02> device_type:Battery
[2026-08-01 17:58:22.407 UTC] [V] 485ChCtl <C3> set rt:0
[2026-08-01 17:58:22.455 UTC] [V] OFSCtrl limit chk 400 < 800 < [1191->1191] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:22.455 UTC] [V] OFSCtrl angif value:1191 power_val_:20643.750000
[2026-08-01 17:58:22.457 UTC] [V] 485ChCtl <C1> StartDeviceCommunicationForOutputFluctuationSuppressionControlBroadcast 4 cnt:179767, monitor_cnt:100, bc_elapsed:17, min:10, max:40
[2026-08-01 17:58:22.457 UTC] [V] OFSCtrl /var/local/solajithome/function/output_fluctuation_suppression/state is exist:0
[2026-08-01 17:58:22.478 UTC] [V] 485ChCtl <C3> StartDeviceCommunicationForOutputFluctuationSuppressionControlBroadcast 4 cnt:179767, monitor_cnt:60, bc_elapsed:179767, min:10, max:40
[2026-08-01 17:58:22.479 UTC] [V] 485DevCtl <C3:03> Dev not PCS IsNeedToChangeOControlState
[2026-08-01 17:58:22.479 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :2
[2026-08-01 17:58:22.480 UTC] [V] 485ChCtl <C3> send request:Sungrow11
[2026-08-01 17:58:22.481 UTC] [D] 485AcReq <C3:03> PutOStream [2][0c0000010000000601042751005e]
[2026-08-01 17:58:22.555 UTC] [V] OFSCtrl limit chk 400 < 800 < [1191->1191] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:22.555 UTC] [V] OFSCtrl angif value:1191 power_val_:20643.750000
[2026-08-01 17:58:22.555 UTC] [V] OFSCtrl Control charge discharge proc start.
[2026-08-01 17:58:22.556 UTC] [V] OFSCtrl CHG 20 p_th(t):20600.850000 = p_th_old_:20630.550000 + lev_cd_:-0.300000 * (total_pcs_capacity_:297000.000000 * cof_spec_:2.000000 / 60 * (time_threshold_renew:10.000000 * 10)), min:-2062.500000, max:407900.000000
[2026-08-01 17:58:22.556 UTC] [V] 485ChCtl <C1> StartDeviceCommunicationForOutputFluctuationSuppressionControlBroadcast 4 cnt:179768, monitor_cnt:101, bc_elapsed:18, min:10, max:40
[2026-08-01 17:58:22.556 UTC] [V] 485DevCtl <C1:02> Dev not PCS IsNeedToChangeOControlState
[2026-08-01 17:58:22.556 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :1
[2026-08-01 17:58:22.557 UTC] [V] 485ChCtl <C1> send request:IMT01
[2026-08-01 17:58:22.558 UTC] [D] 485AcReq <C1:02> PutOStream [1][08000204000200019039]
[2026-08-01 17:58:22.561 UTC] [V] OFSCtrl CHG 21 batt_w:20986.924079 = old:21011.707079 +  kp:0.550000 * e:-42.900000 + ki:0.000000 * sume:-13675.199856 + kd:0.040000 * (e:-42.900000 - e1:-13.200000)
[2026-08-01 17:58:22.561 UTC] [V] OFSCtrl CHG 21 battery threshold min:20000.000000 <= bat:20986.924079 <= max:196000.000000, adjust charge:0.000000, discharge:1000.000000
[2026-08-01 17:58:22.561 UTC] [V] OFSCtrl CHG 29 q:52.000000, mod(round):2.000000
[2026-08-01 17:58:22.561 UTC] [V] OFSCtrl discharge bat_w[0303]:6300.000000 += adjust:1000.000000
[2026-08-01 17:58:22.561 UTC] [D] OFSCtrl battery ctrl val:10.500000
[2026-08-01 17:58:22.564 UTC] [V] 485ChCtl <C3> battery limit on [52.000000,53.000000,63.000000,52.000000,] request.
[2026-08-01 17:58:22.565 UTC] [V] OFSCtrl Control charge discharge proc:01->02->BATT_CHK->03->04->05->06->10->12->13->15->16->18->19->20->21->22->23->24->25->27->23->24->25->27->23->24->25->27->23->24->25->27->28->29->30->31->32->30->31->32->30->31->32->30->31->32->33->34
[2026-08-01 17:58:22.643 UTC] [V] 485DevCtl <C3:03> AnalyzeResponseData proc restart cnt:17982 UPRstat:0
[2026-08-01 17:58:22.655 UTC] [V] OFSCtrl limit chk 400 < 800 < [1191->1191] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:22.656 UTC] [V] OFSCtrl angif value:1191 power_val_:20643.750000
[2026-08-01 17:58:22.681 UTC] [D] 485DevCtl <C3:03> RcvDat status[0] len[197] [0001000000bf0104bc0000ffffffffffff005800000000001000000000000000000000000000000000000000ae0032009a0000000100010001ffffffffffffffffffffffffffffffffffffffff000100000001000000010000ffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffff000101f40000003f0000fffefffffc196e830000647d00000000000000b20000]
[2026-08-01 17:58:22.684 UTC] [D] 485DevCtl <C3:03> ResCnd OperationId [2] IsNormal[1]  ConditionType [lggrdev:Normal] Action[-1]
[2026-08-01 17:58:22.685 UTC] [V] 485DevCtl <C3:03> [02][753049][0.000000][0][]
[2026-08-01 17:58:22.685 UTC] [V] SummDat SetVrmValue dev_id:15 val:0.000000 sc:0
[2026-08-01 17:58:22.689 UTC] [V] OCMgr SetMeterValue PhId:0303, branchNo:02, valueId:753049, value:0.000000, scaleFactor:0, devId:15
[2026-08-01 17:58:22.694 UTC] [V] 485DevCtl <C3:03> [01][753040][16.000000][0][]
[2026-08-01 17:58:22.696 UTC] [V] SummDat SetVrmValue dev_id:15 val:16.000000 sc:0
[2026-08-01 17:58:22.704 UTC] [V] OCMgr SetMeterValue PhId:0303, branchNo:01, valueId:753040, value:16.000000, scaleFactor:0, devId:15
[2026-08-01 17:58:22.708 UTC] [V] 485DevCtl <C3:03> [01][753053][0.000000][0][]
[2026-08-01 17:58:22.709 UTC] [V] SummDat SetVrmValue dev_id:15 val:0.000000 sc:0
[2026-08-01 17:58:22.709 UTC] [V] OCMgr SetMeterValue PhId:0303, branchNo:01, valueId:753053, value:0.000000, scaleFactor:0, devId:15
[2026-08-01 17:58:22.709 UTC] [V] 485DevCtl <C3:03> [02][753053][0.000000][0][]
[2026-08-01 17:58:22.711 UTC] [V] SummDat SetVrmValue dev_id:15 val:0.000000 sc:0
[2026-08-01 17:58:22.717 UTC] [V] OCMgr SetMeterValue PhId:0303, branchNo:02, valueId:753053, value:0.000000, scaleFactor:0, devId:15
[2026-08-01 17:58:22.721 UTC] [V] 485DevCtl <C3:03> [03][753053][0.000000][0][]
[2026-08-01 17:58:22.723 UTC] [V] SummDat SetVrmValue dev_id:15 val:0.000000 sc:0
[2026-08-01 17:58:22.728 UTC] [V] OCMgr SetMeterValue PhId:0303, branchNo:03, valueId:753053, value:0.000000, scaleFactor:0, devId:15
[2026-08-01 17:58:22.732 UTC] [V] 485DevCtl <C3:03> [04][753053][0.000000][0][]
[2026-08-01 17:58:22.734 UTC] [V] SummDat SetVrmValue dev_id:15 val:0.000000 sc:0
[2026-08-01 17:58:22.735 UTC] [V] OCMgr SetMeterValue PhId:0303, branchNo:04, valueId:753053, value:0.000000, scaleFactor:0, devId:15
[2026-08-01 17:58:22.735 UTC] [V] 485DevCtl <C3:03> [01][716202][500.000000][1][kW]
[2026-08-01 17:58:22.738 UTC] [V] SummDat SetVrmValue dev_id:15 val:50.000000 sc:0
[2026-08-01 17:58:22.742 UTC] [V] OCMgr SetMeterValue PhId:0303, branchNo:01, valueId:716202, value:500.000000, scaleFactor:1, devId:15
[2026-08-01 17:58:22.746 UTC] [V] 485DevCtl <C3:03> [01][711102][63.000000][1][kW]
[2026-08-01 17:58:22.752 UTC] [V] SummDat SetVrmValue dev_id:15 val:6300.000000 sc:3
[2026-08-01 17:58:22.755 UTC] [V] OFSCtrl limit chk 400 < 800 < [1191->1191] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:22.755 UTC] [V] OFSCtrl angif value:1191 power_val_:20643.750000
[2026-08-01 17:58:22.763 UTC] [V] Res no response condition. set normal condition.
[2026-08-01 17:58:22.767 UTC] [D] 485DevCtl <C2:01> RcvDat status[2] len[77] [0104480000c1350000127a000000000000000000000000000000000000000000000000000000000000000000000000ffffffffffffffffffffffff00000000000000000000000000001400e9da]
[2026-08-01 17:58:22.767 UTC] [D] 485DevCtl <C2:01> ResCnd OperationId [1] IsNormal[1] 
[2026-08-01 17:58:22.767 UTC] [V] 485DevCtl <C2:01> [01][115202][0.000000][1][kWh]
[2026-08-01 17:58:22.767 UTC] [V] SummDat SetVrmValue dev_id:7 val:0.000000 sc:1
[2026-08-01 17:58:22.768 UTC] [V] OCMgr SetMeterValue PhId:0201, branchNo:01, valueId:115202, value:0.000000, scaleFactor:1, devId:7
[2026-08-01 17:58:22.768 UTC] [V] 485DevCtl <C2:01> [01][113202][49461.000000][0][kWh]
[2026-08-01 17:58:22.768 UTC] [V] SummDat SetVrmValue dev_id:7 val:49461.000000 sc:0
[2026-08-01 17:58:22.769 UTC] [V] OCMgr SetMeterValue PhId:0303, branchNo:01, valueId:711102, value:63.000000, scaleFactor:1, devId:15
[2026-08-01 17:58:22.773 UTC] [V] 485DevCtl <C3:03> [01][703102][28291.000000][0][kWh]
[2026-08-01 17:58:22.773 UTC] [V] SummDat SetVrmValue dev_id:15 val:28291.000000 sc:0
[2026-08-01 17:58:22.773 UTC] [V] OCMgr SetMeterValue PhId:0303, branchNo:01, valueId:703102, value:28291.000000, scaleFactor:0, devId:15
[2026-08-01 17:58:22.773 UTC] [V] 485DevCtl <C3:03> [01][713102][25725.000000][0][kWh]
[2026-08-01 17:58:22.774 UTC] [V] SummDat SetVrmValue dev_id:15 val:25725.000000 sc:0
[2026-08-01 17:58:22.774 UTC] [V] OCMgr SetMeterValue PhId:0303, branchNo:01, valueId:713102, value:25725.000000, scaleFactor:0, devId:15
[2026-08-01 17:58:22.768 UTC] [V] OCMgr SetMeterValue PhId:0201, branchNo:01, valueId:113202, value:49461.000000, scaleFactor:0, devId:7
[2026-08-01 17:58:22.783 UTC] [V] 485DevCtl <C2:01> [01][121005][0.000000][1][℃]
[2026-08-01 17:58:22.784 UTC] [V] 485DevCtl <C3:03> device_type:Battery
[2026-08-01 17:58:22.785 UTC] [V] SummDat SetVrmValue dev_id:7 val:0.000000 sc:3
[2026-08-01 17:58:22.792 UTC] [V] OCMgr SetMeterValue PhId:0201, branchNo:01, valueId:121005, value:0.000000, scaleFactor:1, devId:7
[2026-08-01 17:58:22.793 UTC] [V] 485DevCtl <C2:01> [01][101100][0.000000][1][V]
[2026-08-01 17:58:22.793 UTC] [V] SummDat SetVrmValue dev_id:7 val:0.000000 sc:3
[2026-08-01 17:58:22.793 UTC] [V] OCMgr SetMeterValue PhId:0201, branchNo:01, valueId:101100, value:0.000000, scaleFactor:1, devId:7
[2026-08-01 17:58:22.794 UTC] [V] 485DevCtl <C2:01> [01][101101][0.000000][1][A]
[2026-08-01 17:58:22.794 UTC] [V] SummDat SetVrmValue dev_id:7 val:0.000000 sc:3
[2026-08-01 17:58:22.794 UTC] [V] OCMgr SetMeterValue PhId:0201, branchNo:01, valueId:101101, value:0.000000, scaleFactor:1, devId:7
[2026-08-01 17:58:22.794 UTC] [V] 485DevCtl <C2:01> [02][101100][0.000000][1][V]
[2026-08-01 17:58:22.800 UTC] [V] 485ChCtl <C3> set rt:0
[2026-08-01 17:58:22.807 UTC] [V] SummDat SetVrmValue dev_id:7 val:0.000000 sc:3
[2026-08-01 17:58:22.812 UTC] [V] OCMgr SetMeterValue PhId:0201, branchNo:02, valueId:101100, value:0.000000, scaleFactor:1, devId:7
[2026-08-01 17:58:22.817 UTC] [V] 485DevCtl <C2:01> [02][101101][0.000000][1][A]
[2026-08-01 17:58:22.818 UTC] [V] SummDat SetVrmValue dev_id:7 val:0.000000 sc:3
[2026-08-01 17:58:22.826 UTC] [V] OCMgr SetMeterValue PhId:0201, branchNo:02, valueId:101101, value:0.000000, scaleFactor:1, devId:7
[2026-08-01 17:58:22.828 UTC] [V] 485DevCtl <C2:01> [03][101100][0.000000][1][V]
[2026-08-01 17:58:22.828 UTC] [V] SummDat SetVrmValue dev_id:7 val:0.000000 sc:3
[2026-08-01 17:58:22.829 UTC] [V] OCMgr SetMeterValue PhId:0201, branchNo:03, valueId:101100, value:0.000000, scaleFactor:1, devId:7
[2026-08-01 17:58:22.838 UTC] [V] 485DevCtl <C2:01> [03][101101][0.000000][1][A]
[2026-08-01 17:58:22.839 UTC] [V] SummDat SetVrmValue dev_id:7 val:0.000000 sc:3
[2026-08-01 17:58:22.845 UTC] [V] OCMgr SetMeterValue PhId:0201, branchNo:03, valueId:101101, value:0.000000, scaleFactor:1, devId:7
[2026-08-01 17:58:22.851 UTC] [V] 485DevCtl <C2:01> [01][101102][0.000000][0][W]
[2026-08-01 17:58:22.851 UTC] [V] SummDat SetVrmValue dev_id:7 val:0.000000 sc:3
[2026-08-01 17:58:22.851 UTC] [V] OCMgr SetMeterValue PhId:0201, branchNo:01, valueId:101102, value:0.000000, scaleFactor:0, devId:7
[2026-08-01 17:58:22.857 UTC] [V] OFSCtrl limit chk 400 < 800 < [1191->1191] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:22.857 UTC] [V] OFSCtrl angif value:1191 power_val_:20643.750000
[2026-08-01 17:58:22.859 UTC] [V] 485DevCtl <C2:01> [01][111200][0.000000][1][V]
[2026-08-01 17:58:22.865 UTC] [V] SummDat SetVrmValue dev_id:7 val:0.000000 sc:3
[2026-08-01 17:58:22.865 UTC] [V] OCMgr SetMeterValue PhId:0201, branchNo:01, valueId:111200, value:0.000000, scaleFactor:1, devId:7
[2026-08-01 17:58:22.872 UTC] [V] 485DevCtl <C2:01> [02][111200][0.000000][1][V]
[2026-08-01 17:58:22.876 UTC] [V] SummDat SetVrmValue dev_id:7 val:0.000000 sc:3
[2026-08-01 17:58:22.879 UTC] [V] 485ChCtl <C3> battery send request.1
[2026-08-01 17:58:22.879 UTC] [D] VarInf Limit_Bat rt[2]set val[52] set rate[10.400000] value100[500] value-100[-500]
[2026-08-01 17:58:22.880 UTC] [D] VarInf Limit_Bat rt[2]set val[53] set rate[10.600000] value100[500] value-100[-500]
[2026-08-01 17:58:22.881 UTC] [D] VarInf Limit_Bat rt[2]set val[63] set rate[12.600000] value100[500] value-100[-500]
[2026-08-01 17:58:22.888 UTC] [V] 485DevCtl <C1:02> AnalyzeResponseData proc restart cnt:18000 UPRstat:0
[2026-08-01 17:58:22.888 UTC] [V] Res no response condition. set normal condition.
[2026-08-01 17:58:22.888 UTC] [D] 485DevCtl <C1:02> RcvDat status[2] len[7] [020402020fbc54]
[2026-08-01 17:58:22.888 UTC] [D] 485DevCtl <C1:02> ResCnd OperationId [1] IsNormal[1] 
[2026-08-01 17:58:22.889 UTC] [V] 485DevCtl <C1:02> [01][431005][277.000000][1][°C]
[2026-08-01 17:58:22.889 UTC] [V] SummDat SetVrmValue dev_id:2 val:27700.000000 sc:3
[2026-08-01 17:58:22.889 UTC] [V] OCMgr SetMeterValue PhId:0102, branchNo:01, valueId:431005, value:277.000000, scaleFactor:1, devId:2
[2026-08-01 17:58:22.890 UTC] [V] 485DevCtl <C1:02> device_type:
[2026-08-01 17:58:22.890 UTC] [V] 485ChCtl <C1> set rt:0
[2026-08-01 17:58:22.894 UTC] [V] OCMgr SetMeterValue PhId:0201, branchNo:02, valueId:111200, value:0.000000, scaleFactor:1, devId:7
[2026-08-01 17:58:22.895 UTC] [V] 485DevCtl <C2:01> [03][111200][0.000000][1][V]
[2026-08-01 17:58:22.895 UTC] [V] SummDat SetVrmValue dev_id:7 val:0.000000 sc:3
[2026-08-01 17:58:22.895 UTC] [V] OCMgr SetMeterValue PhId:0201, branchNo:03, valueId:111200, value:0.000000, scaleFactor:1, devId:7
[2026-08-01 17:58:22.911 UTC] [V] 485DevCtl <C2:01> [01][111201][0.000000][1][A]
[2026-08-01 17:58:22.912 UTC] [V] SummDat SetVrmValue dev_id:7 val:0.000000 sc:3
[2026-08-01 17:58:22.885 UTC] [D] VarInf Limit_Bat rt[2]set val[52] set rate[10.400000] value100[500] value-100[-500]
[2026-08-01 17:58:22.915 UTC] [D] 485AcReq <C3:01> PutOStream [6][0f000001000000090110278e0001020034]
[2026-08-01 17:58:22.915 UTC] [D] 485AcReq <C3:02> PutOStream [6][0f000001000000090110278e0001020035]
[2026-08-01 17:58:22.916 UTC] [D] 485AcReq <C3:03> PutOStream [6][0f000001000000090110278e000102003f]
[2026-08-01 17:58:22.916 UTC] [D] 485AcReq <C3:04> PutOStream [6][0f000001000000090110278e0001020034]
[2026-08-01 17:58:22.922 UTC] [V] OCMgr SetMeterValue PhId:0201, branchNo:01, valueId:111201, value:0.000000, scaleFactor:1, devId:7
[2026-08-01 17:58:22.922 UTC] [V] 485DevCtl <C2:01> [02][111201][0.000000][1][A]
[2026-08-01 17:58:22.922 UTC] [V] SummDat SetVrmValue dev_id:7 val:0.000000 sc:3
[2026-08-01 17:58:22.923 UTC] [V] OCMgr SetMeterValue PhId:0201, branchNo:02, valueId:111201, value:0.000000, scaleFactor:1, devId:7
[2026-08-01 17:58:22.923 UTC] [V] 485DevCtl <C2:01> [03][111201][0.000000][1][A]
[2026-08-01 17:58:22.923 UTC] [V] SummDat SetVrmValue dev_id:7 val:0.000000 sc:3
[2026-08-01 17:58:22.944 UTC] [V] OCMgr SetMeterValue PhId:0201, branchNo:03, valueId:111201, value:0.000000, scaleFactor:1, devId:7
[2026-08-01 17:58:22.945 UTC] [V] 485DevCtl <C2:01> [01][111202][0.000000][0][W]
[2026-08-01 17:58:22.945 UTC] [V] SummDat SetVrmValue dev_id:7 val:0.000000 sc:3
[2026-08-01 17:58:22.955 UTC] [V] OFSCtrl limit chk 400 < 800 < [1191->1191] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:22.955 UTC] [V] OFSCtrl angif value:1191 power_val_:20643.750000
[2026-08-01 17:58:22.957 UTC] [V] 485ChCtl <C1> StartDeviceCommunicationForOutputFluctuationSuppressionControlBroadcast 4 cnt:179772, monitor_cnt:105, bc_elapsed:22, min:10, max:40
[2026-08-01 17:58:22.957 UTC] [V] 485DevCtl <C1:03> Dev not PCS IsNeedToChangeOControlState
[2026-08-01 17:58:22.957 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :1
[2026-08-01 17:58:22.958 UTC] [V] 485ChCtl <C1> send request:omron03
[2026-08-01 17:58:22.959 UTC] [D] 485AcReq <C1:03> PutOStream [1][08000303000000144427]
[2026-08-01 17:58:22.963 UTC] [V] OCMgr SetMeterValue PhId:0201, branchNo:01, valueId:111202, value:0.000000, scaleFactor:0, devId:7
[2026-08-01 17:58:22.963 UTC] [V] 485DevCtl <C2:01> [01][111203][0.000000][0][var]
[2026-08-01 17:58:22.964 UTC] [V] SummDat SetVrmValue dev_id:7 val:0.000000 sc:3
[2026-08-01 17:58:22.964 UTC] [V] OCMgr SetMeterValue PhId:0201, branchNo:01, valueId:111203, value:0.000000, scaleFactor:0, devId:7
[2026-08-01 17:58:22.964 UTC] [V] 485DevCtl <C2:01> [01][121007][0.000000][3][]
[2026-08-01 17:58:22.975 UTC] [V] SummDat SetVrmValue dev_id:7 val:0.000000 sc:3
[2026-08-01 17:58:22.986 UTC] [V] OCMgr SetMeterValue PhId:0201, branchNo:01, valueId:121007, value:0.000000, scaleFactor:3, devId:7
[2026-08-01 17:58:22.987 UTC] [V] 485DevCtl <C2:01> [01][131006][0.000000][1][Hz]
[2026-08-01 17:58:22.991 UTC] [V] SummDat SetVrmValue dev_id:7 val:0.000000 sc:3
[2026-08-01 17:58:22.995 UTC] [V] OCMgr SetMeterValue PhId:0201, branchNo:01, valueId:131006, value:0.000000, scaleFactor:1, devId:7
[2026-08-01 17:58:23.002 UTC] [V] 485DevCtl <C2:01> [01][114202][49461.000000][0][kWh]
[2026-08-01 17:58:23.009 UTC] [V] SummDat SetVrmValue dev_id:7 val:49461000.000000 sc:3
[2026-08-01 17:58:23.012 UTC] [V] OFSCtrl [/var/local/solajithome/function/output_fluctuation_suppression/batt_data] write success.
[2026-08-01 17:58:23.013 UTC] [V] OCMgr SetMeterValue PhId:0201, branchNo:01, valueId:114202, value:49461.000000, scaleFactor:0, devId:7
[2026-08-01 17:58:23.018 UTC] [V] 485DevCtl <C2:01> device_type:PV-PCS
[2026-08-01 17:58:23.025 UTC] [V] 485DevCtl <C2:01> set2 StatusCode[010100] DeviceName[] DeviceNumber[]
[2026-08-01 17:58:23.025 UTC] [V] 485ChCtl <C2> set rt:0
[2026-08-01 17:58:23.055 UTC] [V] OFSCtrl limit chk 400 < 800 < [1191->1191] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:23.055 UTC] [V] OFSCtrl angif value:1191 power_val_:20643.750000
[2026-08-01 17:58:23.064 UTC] [V] 485ChCtl <C2> StartDeviceCommunicationForOutputFluctuationSuppressionControlBroadcast 4 cnt:179773, monitor_cnt:57, bc_elapsed:179773, min:10, max:40
[2026-08-01 17:58:23.064 UTC] [V] SCCtl  GetRegistryPurchaseMeterOperationId :1
[2026-08-01 17:58:23.065 UTC] [V] 485ChCtl <C2> send request:Sungrow08
[2026-08-01 17:58:23.066 UTC] [D] 485AcReq <C2:02> PutOStream [1][08000204138a0024d54c]
[2026-08-01 17:58:23.104 UTC] [V] 485DevCtl <C3:01> AnalyzeResponseData proc restart cnt:17982 UPRstat:0
[2026-08-01 17:58:23.107 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:58:23.108 UTC] [D] 485DevCtl <C3:01> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:58:23.108 UTC] [D] 485DevCtl <C3:01> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:58:23.108 UTC] [V] 485DevCtl <C3:01> device_type:Battery
[2026-08-01 17:58:23.108 UTC] [V] 485DevCtl <C3:02> AnalyzeResponseData proc restart cnt:17982 UPRstat:0
[2026-08-01 17:58:23.110 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:58:23.110 UTC] [D] 485DevCtl <C3:02> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:58:23.110 UTC] [D] 485DevCtl <C3:02> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:58:23.110 UTC] [V] 485DevCtl <C3:02> device_type:Battery
[2026-08-01 17:58:23.111 UTC] [V] 485DevCtl <C3:03> AnalyzeResponseData proc restart cnt:17982 UPRstat:0
[2026-08-01 17:58:23.112 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:58:23.141 UTC] [D] 485DevCtl <C3:03> RcvDat status[0] len[12] [0001000000060110278e0001]
[2026-08-01 17:58:23.145 UTC] [D] 485DevCtl <C3:03> ResCnd OperationId [6] IsNormal[1] 
[2026-08-01 17:58:23.148 UTC] [V] 485DevCtl <C3:03> device_type:Battery
[2026-08-01 17:58:23.155 UTC] [V] OFSCtrl limit chk 400 < 800 < [1191->1191] < 4000 < 4000 , cnt:0:0:601 
[2026-08-01 17:58:23.156 UTC] [V] OFSCtrl angif value:1191 power_val_:20643.750000
[2026-08-01 17:58:23.156 UTC] [V] 485DevCtl <C3:04> AnalyzeResponseData proc restart cnt:17982 UPRstat:0
[2026-08-01 17:58:23.177 UTC] [V] Query CheckPresetMultipleResisterRequest check data:0c000001000000090110278e0001 - 0110278e0001
[2026-08-01 17:58:23.188 UTC] [D] 485DevCtl <C3:04> RcvDat status[0] len[12] [0001000000060110278e0001]